1725015642000 | 0 | None | None | Buildings | Construction of Anganwadi Building at Beeranholi of Hukkeri Taluka Belagavi Dist | 1717631.34 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3887850 | 149386 | None | code01 | Demolishing cement concrete manually/ by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge. complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Cum | 1663.0 | 1663.0 | 7.99 | False | None | None | False | None | False | 13287.37 | 0 | 3887851 | 149386 | None | code02 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineerin- charge.complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Cum | 1684.0 | 1684.0 | 36.19 | False | None | None | False | None | False | 60943.96 | 0 | 3887852 | 149386 | None | code03 | Earth work in surface excavation by mechanical means for lowering & leveling the ground without blasting for all works other than foundation in Ordinary/Soft rock & depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Cum | 362.0 | 362.0 | 34.92 | False | None | None | False | None | False | 12641.04 | 0 | 3887853 | 149386 | None | code04 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Cum | 6243.0 | 6243.0 | 13.21 | False | None | None | False | None | False | 82470.03 | 0 | 3887854 | 149386 | None | code05 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand) complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Cum | 5611.0 | 5611.0 | 15.64 | False | None | None | False | None | False | 87756.04 | 0 | 3887855 | 149386 | None | code06 | Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Cum | 6205.0 | 6205.0 | 9.91 | False | None | None | False | None | False | 61491.55 | 0 | 3887856 | 149386 | None | code07 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. Column Footing complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Cum | 6475.61 | 6475.61 | 3.42 | False | None | None | False | None | False | 22146.5862 | 0 | 3887857 | 149386 | None | code08 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Col Up To GL complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Cum | 10749.1 | 10749.1 | 0.71 | False | None | None | False | None | False | 7631.861 | 0 | 3887858 | 149386 | None | code09 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Septic Tank complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Cum | 9484.5 | 9484.5 | 0.375 | False | None | None | False | None | False | 3556.6875 | 0 | 3887859 | 149386 | None | code10 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Plinth Beam complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Cum | 9945.0 | 9945.0 | 5.06 | False | None | None | False | None | False | 50321.7 | 0 | 3887860 | 149386 | None | code11 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Column complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Cum | 11271.0 | 11271.0 | 3.21 | False | None | None | False | None | False | 36179.91 | 0 | 3887861 | 149386 | None | code12 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Lintel & Roof Beam complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Cum | 10608.0 | 10608.0 | 6.47 | False | None | None | False | None | False | 68633.76 | 0 | 3887862 | 149386 | None | code13 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Slab complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Cum | 9945.0 | 9945.0 | 11.78 | False | None | None | False | None | False | 117152.1 | 0 | 3887863 | 149386 | None | code14 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification TMT bars Fe-500 complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | MT | 89457.0 | 89457.0 | 3.0493 | False | None | None | False | None | False | 272781.2301 | 0 | 3887864 | 149386 | None | code15 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Cum | 266.0 | 266.0 | 24.32 | False | None | None | False | None | False | 6469.12 | 0 | 3887865 | 149386 | None | code16 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8211.0 | 8211.0 | 31.22 | False | None | None | False | None | False | 256347.42 | 0 | 3887866 | 149386 | None | code17 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 1060.0 | 1060.0 | 1.62 | False | None | None | False | None | False | 1717.2 | 0 | 3887867 | 149386 | None | code18 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 323.0 | 323.0 | 287.02 | False | None | None | False | None | False | 92707.46 | 0 | 3887868 | 149386 | None | code19 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 385.0 | 385.0 | 151.4 | False | None | None | False | None | False | 58289.0 | 0 | 3887869 | 149386 | None | code20 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Sqm | 137.0 | 137.0 | 277.15 | False | None | None | False | None | False | 37969.55 | 0 | 3887870 | 149386 | None | code21 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Sqm | 53.0 | 53.0 | 166.68 | False | None | None | False | None | False | 8834.04 | 0 | 3887871 | 149386 | None | code22 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Sqm | 89.0 | 89.0 | 166.68 | False | None | None | False | None | False | 14834.52 | 0 | 3887872 | 149386 | None | code23 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Kg | 168.0 | 168.0 | 142.56 | False | None | None | False | None | False | 23950.08 | 0 | 3887873 | 149386 | None | code24 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8+-0.2 mm. Maximum possible size 1519mm x 1519mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Sqm | 5390.0 | 5390.0 | 5.76 | False | None | None | False | None | False | 31046.4 | 0 | 3887874 | 149386 | None | code25 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Cum | 138074.0 | 138074.0 | 0.383 | False | None | None | False | None | False | 52882.342 | 0 | 3887875 | 149386 | None | code26 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Sqm | 5742.0 | 5742.0 | 10.08 | False | None | None | False | None | False | 57879.36 | 0 | 3887876 | 149386 | None | code27 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | Mtr | 318.0 | 318.0 | 5.1 | False | None | None | False | None | False | 1621.8 | 0 | 3887877 | 149386 | None | code28 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Sqm | 2366.0 | 2366.0 | 1.35 | False | None | None | False | None | False | 3194.1 | 0 | 3887878 | 149386 | None | code29 | Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm hickness, including grouting of joints (Payment for grouting of joints to be made separately). complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Sqm | 1238.0 | 1238.0 | 52.2 | False | None | None | False | None | False | 64623.6 | 0 | 3887879 | 149386 | None | code30 | Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Sqm | 1246.0 | 1246.0 | 15.58 | False | None | None | False | None | False | 19412.68 | 0 | 3887880 | 149386 | None | code31 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Sqm | 1392.0 | 1392.0 | 2.52 | False | None | None | False | None | False | 3507.84 | 0 | 3887881 | 149386 | None | code32 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Sqm | 1650.0 | 1650.0 | 6.98 | False | None | None | False | None | False | 11517.0 | 0 | 3887882 | 149386 | None | code33 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 250 mm complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | No | 5618.0 | 5618.0 | 1.0 | False | None | None | False | None | False | 5618.0 | 0 | 3887883 | 149386 | None | code34 | Providing and fixing white vitreous china water closet squatting pan (Indian type) : Orissa pattern W.C. pan of size 580x440 mm complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | No | 2331.0 | 2331.0 | 1.0 | False | None | None | False | None | False | 2331.0 | 0 | 3887884 | 149386 | None | code35 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | l | 9.0 | 9.0 | 500.0 | False | None | None | False | None | False | 4500.0 | 0 | 3887885 | 149386 | None | code36 | Providing and fixing brass bib cock of approved quality : 15 mm nominal bore complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | No | 286.0 | 286.0 | 3.0 | False | None | None | False | None | False | 858.0 | 0 | 3887886 | 149386 | None | code37 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | No | 166.0 | 166.0 | 35.0 | False | None | None | False | None | False | 5810.0 | 0 | 3887887 | 149386 | None | code38 | Lettering with black Japan paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Sqm | 4.0 | 4.0 | 6600.0 | False | None | None | False | None | False | 26400.0 | 0 | 3887888 | 149386 | None | code39 | Supplying 6A flush type socket and 6A flush type SP switch either surface /flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854 complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | No | 147.0 | 147.0 | 8.0 | False | None | None | False | None | False | 1176.0 | 0 | 3887889 | 149386 | None | code40 | Supplying and fixing superior quality modular switch mounting poly car bonat eplate withne cessary supporting back plate with requir ed nos.of machine screws, bolts nuts etc., complete on the existing metal /PVC box. complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | No | 175.0 | 175.0 | 8.0 | False | None | None | False | None | False | 1400.0 | 0 | 3887890 | 149386 | None | code41 | Supplying and flush mounting teak wooden box without front plank, madeo fnot lessthan 12mm thick wood, after due groove cutting, finishing with necessary cement plastering complete.complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Each | 120.0 | 120.0 | 4.0 | False | None | None | False | None | False | 480.0 | 0 | 3887891 | 149386 | None | code42 | Wiring for lighting/ power circuit using one of FRLSPVC insulated 1100V grade, multistr and copper wire with low conductorr esistance single coreinopen or conce aled system of wiring with specified IS-694:2010 1.5 mm2 complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Mtr | 26.0 | 26.0 | 80.0 | False | None | None | False | None | False | 2080.0 | 0 | 3887892 | 149386 | None | code43 | Wiring for lighting/ power circuit using one of FRLSPVC insulated 1100V grade, multistr and copper wire with low conductorr esistance single coreinopen or conce aled system of wiring with specified IS-694:2010 2.5 mm2 complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Mtr | 42.0 | 42.0 | 82.0 | False | None | None | False | None | False | 3444.0 | 0 | 3887893 | 149386 | None | code44 | Wiring for lighting/ power circuit using one of FRLSPVC insulated 1100V grade, multistr and copper wire with low conductorr esistance single coreinopen or conce aled system of wiring with specified IS-694:2010 1 mm2 complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Mtr | 19.0 | 19.0 | 85.0 | False | None | None | False | None | False | 1615.0 | 0 | 3887894 | 149386 | None | code45 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary material slike bends, junction box, elbows, screwsatan interval of 300 mm as required. complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Mtr | 35.0 | 35.0 | 80.0 | False | None | None | False | None | False | 2800.0 | 0 | 3887895 | 149386 | None | code46 | Supplying and drawing Flexible Multi core Cable manufactured withel ect rolytic grade flexible copper with low conduct or confirming toIS8130-1984and (Virgin) PVC insulations heath edsuitable forworking voltage upto 1100 Volts as per IS-694:1990 complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Mtr | 175.0 | 175.0 | 25.0 | False | None | None | False | None | False | 4375.0 | 0 | 3887896 | 149386 | None | code47 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles.Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system.complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | Nos | 2984.0 | 2984.0 | 1.0 | False | None | None | False | None | False | 2984.0 | 0 | 3887897 | 149386 | None | code48 | Supplying & fixing miniature circuit breaker son existing MCB distribution board susing necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10 Kand complete wiring as required confirming to IEC 60898. complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | No | 739.0 | 739.0 | 1.0 | False | None | None | False | None | False | 739.0 | 0 | 3887898 | 149386 | None | code49 | Fixing all type sand all capacities offl uorescent/ fals eceiling/ spotlight/ CFL/ LED fitting sindoor on the wall/ ceiling/ rafters/ girders using 23/0.0076" twintwisted PVC insulated wires, required No so fround blocks and clamps. complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | No | 122.0 | 122.0 | 14.0 | False | None | None | False | None | False | 1708.0 | 0 | 3887899 | 149386 | None | code50 | Supplying and wiring adopting loop systemin existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase&Neutral) &1x1.0sqmm (Earthwire) FRLS multistr and PVC insulated copper wire (confirmingtoIS-694:andlatestamendments) with a 6Amps flush type SP control switch shall befixed onthe existing plasticsheet /gangbox, theother end ofthe wires shall beterminated with sufficien tloose leng thina wood/ PVC round block.completeforeach outlet. complete with all leads and lifts. with all lead and lifts etc., complete as per direction of the Engineer-in-charge of the work. | No | 394.0 | 394.0 | 14.0 | False | None | None | False | None | False | 5516.0 | 0 |
|