3885400 | 149276 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m | Cum | 112.2 | 112.2 | 2386.92 | False | None | None | False | None | False | 267812.424 | 0 |
3885401 | 149276 | None | code02 | Providing and Spreading of Sand under floors, foundation of Bridges including watering, ramming, consolidating and dressing complete. | Cum | 2394.7 | 2394.7 | 47.82 | False | None | None | False | None | False | 114514.554 | 0 |
3885402 | 149276 | None | code03 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 292.6 | 292.6 | 1524.25 | False | None | None | False | None | False | 445995.55 | 0 |
3885403 | 149276 | None | code04 | Loading and Unloading of Stone Boulder/Stone aggregates/Sand/ Kankar/Moorum. (Tipper 10 m3) | Cum | 130.9 | 130.9 | 1432.15 | False | None | None | False | None | False | 187468.435 | 0 |
3885404 | 149276 | None | code05 | Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications(Soling work) | Cum | 2950.2 | 2950.2 | 290.14 | False | None | None | False | None | False | 855971.028 | 0 |
3885405 | 149276 | None | code06 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6587.9 | 6587.9 | 205.39 | False | None | None | False | None | False | 1353088.781 | 0 |
3885406 | 149276 | None | code07 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7318.08 | 7318.08 | 663.55 | False | None | None | False | None | False | 4855911.984 | 0 |
3885407 | 149276 | None | code08 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11404.8 | 11404.8 | 71.47 | False | None | None | False | None | False | 815101.056 | 0 |
3885408 | 149276 | None | code09 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings | MT | 98402.7 | 98402.7 | 141.12 | False | None | None | False | None | False | 13886589.024 | 0 |
3885409 | 149276 | None | code10 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 389.4 | 389.4 | 362.8 | False | None | None | False | None | False | 141274.32 | 0 |
3885410 | 149276 | None | code11 | Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel reinforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis) | Sqm | 676.5 | 676.5 | 362.8 | False | None | None | False | None | False | 245434.2 | 0 |
3885411 | 149276 | None | code12 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete | Sqm | 1216.6 | 1216.6 | 1119.93 | False | None | None | False | None | False | 1362506.838 | 0 |
3885412 | 149276 | None | code13 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Kgs | 621.5 | 621.5 | 543.2 | False | None | None | False | None | False | 337598.8 | 0 |
3885413 | 149276 | None | code14 | Providing, laying & fixing cement base, precast, pre polished cement concrete, designer tiles 25mm thick conforming to IS 1237 heavy duty tiles for flooring, treads of steps and landing, laid on a bed of 12mm thick cement mortar 1:3 mis finished with flush pointing using white cement, including cost of materials, mortar, including cutting, griding the edge to half/full round wherever required, labour, curing complete as per specification | Sqm | 1025.2 | 1025.2 | 204.0 | False | None | None | False | None | False | 209140.8 | 0 |
3885414 | 149276 | None | code15 | Providing and laying Black Lapotra Granite stone flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. | Sqm | 2840.2 | 2840.2 | 120.0 | False | None | None | False | None | False | 340824.0 | 0 |
3885415 | 149276 | None | code16 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m | Cum | 251.9 | 251.9 | 1423.71 | False | None | None | False | None | False | 358632.549 | 0 |
3885416 | 149276 | None | code17 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 129.8 | 129.8 | 291.6 | False | None | None | False | None | False | 37849.68 | 0 |
3885417 | 149276 | None | code18 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 476.3 | 476.3 | 92.11 | False | None | None | False | None | False | 43871.993 | 0 |
3885418 | 149276 | None | code19 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 7027.9 | 7027.9 | 37.57 | False | None | None | False | None | False | 264038.203 | 0 |
3885419 | 149276 | None | code20 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, abour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7527.17 | 7527.17 | 28.73 | False | None | None | False | None | False | 216255.5941 | 0 |
3885420 | 149276 | None | code21 | Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 10731.6 | 10731.6 | 28.04 | False | None | None | False | None | False | 300914.064 | 0 |
3885421 | 149276 | None | code22 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates) | Cum | 7293.0 | 7293.0 | 27.54 | False | None | None | False | None | False | 200849.22 | 0 |
3885422 | 149276 | None | code23 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 12796.41 | 12796.41 | 8.38 | False | None | None | False | None | False | 107233.9158 | 0 |
3885423 | 149276 | None | code24 | Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7840.8 | 7840.8 | 64.45 | False | None | None | False | None | False | 505339.56 | 0 |
3885424 | 149276 | None | code25 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 11290.95 | 11290.95 | 36.84 | False | None | None | False | None | False | 415958.598 | 0 |
3885425 | 149276 | None | code26 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 12043.68 | 12043.68 | 12.26 | False | None | None | False | None | False | 147655.5168 | 0 |
3885426 | 149276 | None | code27 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1441.0 | 1441.0 | 793.09 | False | None | None | False | None | False | 1142842.69 | 0 |
3885427 | 149276 | None | code28 | Providing and constructing non-load bearing wall with solid concrete blocks of size 400x100x200mm having a block density not less than 1800kg/m3 having a minimumm average compressive strength of 4.00 N/mm2 confirming to I.S : 2185(Part 1):2005 and constructed withCM 1:4 as per 2572:2005 including cost of all materials labour charges, scaffolding, curing, hire charges of machineries etc complete as per specifications. | Sqm | 1214.4 | 1214.4 | 53.64 | False | None | None | False | None | False | 65140.416 | 0 |
3885428 | 149276 | None | code29 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing andremoving scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 343.2 | 343.2 | 329.2 | False | None | None | False | None | False | 112981.44 | 0 |
3885429 | 149276 | None | code30 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 383.9 | 383.9 | 891.32 | False | None | None | False | None | False | 342177.748 | 0 |
3885430 | 149276 | None | code31 | Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 471.9 | 471.9 | 1311.85 | False | None | None | False | None | False | 619062.015 | 0 |
3885431 | 149276 | None | code32 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 110.0 | 110.0 | 1220.52 | False | None | None | False | None | False | 134257.2 | 0 |
3885432 | 149276 | None | code33 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge | Sqm | 55.0 | 55.0 | 1220.52 | False | None | None | False | None | False | 67128.6 | 0 |
3885433 | 149276 | None | code34 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. | Sqm | 121.0 | 121.0 | 1220.52 | False | None | None | False | None | False | 147682.92 | 0 |
3885434 | 149276 | None | code35 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 191.4 | 191.4 | 1018.93 | False | None | None | False | None | False | 195023.202 | 0 |
3885435 | 149276 | None | code36 | Providing Sal wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, HOM complete as per specifications. | Cum | 108696.5 | 108696.5 | 1.09 | False | None | None | False | None | False | 118479.185 | 0 |
3885436 | 149276 | None | code37 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 30 mm thick both side Teak | Sqm | 4447.3 | 4447.3 | 15.36 | False | None | None | False | None | False | 68310.528 | 0 |
3885437 | 149276 | None | code38 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | m | 349.8 | 349.8 | 45.6 | False | None | None | False | None | False | 15950.88 | 0 |
3885438 | 149276 | None | code39 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side& 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles& rails with PVC Designer beading on either side & joined together with solvent cementadhesiveetc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with3 nos of 75mm Aluminium hinges. | Sqm | 2244.0 | 2244.0 | 12.6 | False | None | None | False | None | False | 28274.4 | 0 |
3885439 | 149276 | None | code40 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1117.6 | 1117.6 | 4.0 | False | None | None | False | None | False | 4470.4 | 0 |
3885440 | 149276 | None | code41 | Providing & fixing of 3 track x 2 panel sliding windows made out of multi chambered UPVC (Matching to RAL - 9016) sections and with minimum TiO 2 (Titanium Dioxide) at 6PHR with TPV (Thermo Plastic Vulcanized) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having a overall size of 108mm width x 45mm height with reinforcement of 1mm thickness and sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 30mm x 48.5mm Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 5mm plain float glass, standard hardware & single point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2119mm. | Sqm | 7407.4 | 7407.4 | 31.68 | False | None | None | False | None | False | 234666.432 | 0 |
3885441 | 149276 | None | code42 | Providing and fixing M.S.grill work for windows and ventilators using M.S. flats, or M.S. square rods, or combination of M.S. flats and square rods as per approved design, drawing including cutting steel sections and welding the same to required pattern with a coat of red lead primer, cost of materials, fixtures, labour and HOM complete as per specifications. | Kgs | 184.8 | 184.8 | 816.48 | False | None | None | False | None | False | 150885.504 | 0 |
3885442 | 149276 | None | code43 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed,including cost of materials, mortar, labour, curing complete as per specifications | Sqm | 5860.8 | 5860.8 | 44.25 | False | None | None | False | None | False | 259340.4 | 0 |
3885443 | 149276 | None | code44 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. | Mtr | 360.8 | 360.8 | 44.25 | False | None | None | False | None | False | 15965.4 | 0 |
3885444 | 149276 | None | code45 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete. | Sqm | 1216.6 | 1216.6 | 175.26 | False | None | None | False | None | False | 213221.316 | 0 |
3885445 | 149276 | None | code46 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. | Sqm | 898.7 | 898.7 | 270.11 | False | None | None | False | None | False | 242747.857 | 0 |
3885446 | 149276 | None | code47 | Providing 20mm square M.S.Footrest and fixing in manhole with 1:3:6 cement cocnrete block of 20x20x10cms using 20mm and down size metal of size inlcuding cost of materials, labour charges, curing complete as per specifications. | Nos | 303.6 | 303.6 | 5.0 | False | None | None | False | None | False | 1518.0 | 0 |
3885447 | 149276 | None | code48 | Providing and fixing to wall, ceiling and floor, low density polyethylene pipes 6.00 kgf/s.cm working pressure 160mm outside diameter, compression type fittings, wall clips, making good the wall, ceiling and floor including cost of all materials, labour charges, HOM of equipments and testing, excluding cost of fittings, complete as per specifications. (2 runs) | Mtr | 677.16 | 677.16 | 140.0 | False | None | None | False | None | False | 94802.4 | 0 |
3885448 | 149276 | None | code49 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 13699.69 | 13699.69 | 8.52 | False | None | None | False | None | False | 116721.3588 | 0 |
3885449 | 149276 | None | code50 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 12194.23 | 12194.23 | 11.6 | False | None | None | False | None | False | 141453.068 | 0 |
3885450 | 149276 | None | code51 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 12946.96 | 12946.96 | 17.62 | False | None | None | False | None | False | 228125.4352 | 0 |
3885451 | 149276 | None | code52 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 11290.95 | 11290.95 | 38.28 | False | None | None | False | None | False | 432217.566 | 0 |
3885452 | 149276 | None | code53 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 10914.59 | 10914.59 | 0.95 | False | None | None | False | None | False | 10368.8605 | 0 |
3885453 | 149276 | None | code54 | Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-charge (Door handle,lock and stopper etc. to be paid separately) including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 5194.2 | 5194.2 | 3.6 | False | None | None | False | None | False | 18699.12 | 0 |
3885454 | 149276 | None | code55 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x1200 mm | Sqm | 1478.4 | 1478.4 | 135.7 | False | None | None | False | None | False | 200618.88 | 0 |
3885455 | 149276 | None | code56 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1593.9 | 1593.9 | 27.14 | False | None | None | False | None | False | 43258.446 | 0 |
3885456 | 149276 | None | code57 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed,including cost of materials, mortar, labour, curing complete as per specifications | Sqm | 5860.8 | 5860.8 | 211.78 | False | None | None | False | None | False | 1241200.224 | 0 |
3885457 | 149276 | None | code58 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. | Mtr | 360.8 | 360.8 | 181.7 | False | None | None | False | None | False | 65557.36 | 0 |
3885458 | 149276 | None | code59 | Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. | Sqm | 8747.2 | 8747.2 | 41.4 | False | None | None | False | None | False | 362134.08 | 0 |
3885459 | 149276 | None | code60 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. | Kgs | 125.54 | 125.54 | 11022.54 | False | None | None | False | None | False | 1383769.6716 | 0 |
3885460 | 149276 | None | code61 | Providing,fabricating and fixing Profiled Poly Urethane insulated Roof(PUF Sheet) having modular density 40kg/m2 and size 1.06m width and 7.60m length sheets roof having external sheet of 0.5mm steel, bottom sheet of 0.40mm steel with powder coated finish. The precoated sheet shall be of minimum 240MPa steel conforming to IS 14246 : 1995 and shal have zinc coating with minimum 120gsm as per IS 277:1992,.The roofing system shall have suitable water proof over lapping arrangments and GRIHA ceritifed.The fasting shall be of self tapping screws of required length with PVC head along with washer pre-painted aluminium cap unit with build in seal arrangments. The entire roof shall be firmly fastened to the existng frame including all lead and lifts, loading & unloading ,usage charges of machinery and equipments, transportation charges,labour charges and all other incidental charges etc.,complete as per standard technical detailed specifications and as directed by the Engineer in charge of the work.50mm thickness | Sqm | 2883.05 | 2883.05 | 294.52 | False | None | None | False | None | False | 849115.886 | 0 |
3885461 | 149276 | None | code62 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete.For Straight Portion | Sqm | 4431.78 | 4431.78 | 332.0 | False | None | None | False | None | False | 1471350.96 | 0 |
3885462 | 149276 | None | code63 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 311.3 | 311.3 | 370.08 | False | None | None | False | None | False | 115205.904 | 0 |
3885463 | 149276 | None | code64 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete.For Straight Portion | Sqm | 4387.9 | 4387.9 | 108.72 | False | None | None | False | None | False | 477052.488 | 0 |
3885464 | 149276 | None | code65 | Fabricating ,providing and erecting in position of MS Hot Dip Galvanized Sq. Hallow Poles of 132 x 132 Heavy gauge of length 3000mm with MS . Hot dip galvanized grill work as per approved design and drawing of Chief a rchitect. Using 12 x 75mm galvanized flat for alround frame and 20mm x 20mm galvanized-forged design with square for vertical at 150mm C/C as shown in the drawing including providing forged ornamental arrowhed at top and bottom. The work is inclusive of throughing flat, square rods , placing welding all the joints , including grinding finishing 2 coats of anticorrosive paint over one coat of metal primer. The rate is inclusive of allmaterials like MS Hollow galvanized pipe, flats, forged square rods, cost of labour for all items of items of work cost painting, welding, cutting, grinding with all lead and lift as per specification including loading and unloading with cost and conveyance of all materials, labour machinery and incidental charges for the sucessful completion of the work as per the direction Engineering-in- charge for the work (APPROVED RATE). | Sqm | 9144.0 | 9144.0 | 19.8 | False | None | None | False | None | False | 181051.2 | 0 |
3885465 | 149276 | None | code66 | Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped,probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test etc.complete. | Nos | 5816.8 | 5816.8 | 1.0 | False | None | None | False | None | False | 5816.8 | 0 |
3885466 | 149276 | None | code67 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc.,complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes,collars, cap etc., complete ) (Above 450m of drilling add 10% for every 50m depth) 0.00 to 50.00 mtrs | Mtr | 407.0 | 407.0 | 50.0 | False | None | None | False | None | False | 20350.0 | 0 |
3885467 | 149276 | None | code68 | 50.00 to 100.00 mtrs | Mtr | 510.4 | 510.4 | 50.0 | False | None | None | False | None | False | 25520.0 | 0 |
3885468 | 149276 | None | code69 | 100.00 to 150.00 mtrs | Mtr | 542.3 | 542.3 | 50.0 | False | None | None | False | None | False | 27115.0 | 0 |
3885469 | 149276 | None | code70 | 150.00 to 200 mtrs | Mtr | 629.2 | 629.2 | 50.0 | False | None | None | False | None | False | 31460.0 | 0 |
3885470 | 149276 | None | code71 | 200 to 250 mtrs | Mtr | 738.1 | 738.1 | 50.0 | False | None | None | False | None | False | 36905.0 | 0 |
3885471 | 149276 | None | code72 | 250 to 300 mtrs | Mtr | 814.0 | 814.0 | 50.0 | False | None | None | False | None | False | 40700.0 | 0 |
3885472 | 149276 | None | code73 | 300 to 350 mtrs | Mtr | 954.8 | 954.8 | 15.0 | False | None | None | False | None | False | 14322.0 | 0 |
3885473 | 149276 | None | code74 | Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. | Mtr | 193.3 | 193.3 | 20.0 | False | None | None | False | None | False | 3866.0 | 0 |
3885474 | 149276 | None | code75 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 250mm dia. | Mtr | 1401.4 | 1401.4 | 20.0 | False | None | None | False | None | False | 28028.0 | 0 |
3885475 | 149276 | None | code76 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work.12.50 HP - 90 LPM @ 264 m = 24 STG Outlet Dia - 2.00” | Nos | 70540.8 | 70540.8 | 1.0 | False | None | None | False | None | False | 70540.8 | 0 |
3885476 | 149276 | None | code77 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 V as per IS-694:2010. 3C x 6 mm2 | Mtr | 269.5 | 269.5 | 660.0 | False | None | None | False | None | False | 177870.0 | 0 |
3885477 | 149276 | None | code78 | Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover 50 mm | Each | 3355.0 | 3355.0 | 50.0 | False | None | None | False | None | False | 167750.0 | 0 |
3885478 | 149276 | None | code79 | Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mm | Each | 1375.0 | 1375.0 | 1.0 | False | None | None | False | None | False | 1375.0 | 0 |
3885479 | 149276 | None | code80 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor typ e NOTE: 1) DOLDirect Online Starter 2) S-D- Star Delta Starter 6 to 15 HP pumps | Nos | 19250.0 | 19250.0 | 1.0 | False | None | None | False | None | False | 19250.0 | 0 |
3885480 | 149276 | None | code81 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. | Nos | 7150.0 | 7150.0 | 1.0 | False | None | None | False | None | False | 7150.0 | 0 |
3885481 | 149276 | None | code82 | Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) Light Duty GI pipe of 50mm dia | Nos | 486.2 | 486.2 | 3.0 | False | None | None | False | None | False | 1458.6 | 0 |
3885482 | 149276 | None | code83 | Providing and fixing GI union in existing GI pipe line, cutting and threading the pipe and making long screws including excavation, refilling the earth or cutting of wall and making good the same complete wherever required etc. for: 20.88.6: 50 mm nominal bore | Each | 726.0 | 726.0 | 1.0 | False | None | None | False | None | False | 726.0 | 0 |
3885483 | 149276 | None | code84 | Supply and delivery at site wrought middle steel (galvanized) GI elbow confirming to IS 1239-II, 1991 with latest amendments if any for: For 50 mm dia GI elbow | Nos | 293.7 | 293.7 | 1.0 | False | None | None | False | None | False | 293.7 | 0 |
3885484 | 149276 | None | code85 | Supply and delivery at site wrought middle steel (galvanized) GI hexagonal nipple confirming to IS 1239-II, 1991 with latest amendments if any. For 50 mm dia GI hexagonal nipple | Nos | 234.3 | 234.3 | 1.0 | False | None | None | False | None | False | 234.3 | 0 |
3885485 | 149276 | None | code86 | Providing wrought mild steel (galvanized) 15 mm dia GI collar confirming to IS 1239-II, 1991 with latest amendments if any. For 50 mm dia GI collar: | Mtr | 293.7 | 293.7 | 1.0 | False | None | None | False | None | False | 293.7 | 0 |
3885486 | 149276 | None | code87 | Fabrication supplying and mounting MS box of 14 SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished 2 coats of red oxide primer paint and finally finished with approved colour enamelled metal paint etc., complete | Sq CM | 0.55 | 0.55 | 10000.0 | False | None | None | False | None | False | 5500.0 | 0 |
3885487 | 149276 | None | code88 | Supplying and fixing angle iron frame fabricated out of MS Angle iron and MS flat with Bolts,watches etc and painted with finished with 2 coats of red oxide primer paint and finally finished with approved colour enamelled metal paint etc., complete | Mtr | 434.5 | 434.5 | 4.0 | False | None | None | False | None | False | 1738.0 | 0 |
3885488 | 149276 | None | code89 | Supplying of TPST with rewirable porcelain channels in SM enclosure 32 amps made out of 14 SWG Powder coated painted of Approved color. | Nos | 1871.1 | 1871.1 | 1.0 | False | None | None | False | None | False | 1871.1 | 0 |
3885489 | 149276 | None | code90 | Supplying and fixing 20''x20''x2.5'' ppolished wood board made of not less than 15mm thick plan on both sides with planks made out of more than two pieces and fixing the same to the wall using tapered inverted wooden plugs, screws etc . | Nos | 358.74 | 358.74 | 1.0 | False | None | None | False | None | False | 358.74 | 0 |
3885490 | 149276 | None | code91 | Supplying and fixing of LED type panel boradindicating lamp with required color suitable for 220v A.C 50 Hz 12/24v D.C Group-A . | Nos | 566.5 | 566.5 | 1.0 | False | None | None | False | None | False | 566.5 | 0 |
3885491 | 149276 | None | code92 | Supplying fully automatic star-delta starter unit push button type with suitable wires, 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 volts 3 phase and wired after fixing to the existing wooden board for motor Upto 12.5 HP | Nos | 8200.5 | 8200.5 | 1.0 | False | None | None | False | None | False | 8200.5 | 0 |
3885492 | 149276 | None | code93 | Supplying and fixing single phase preventer using necessary wires over an existing panel board suitable for motor up to 20 HP capacities. | Nos | 994.42 | 994.42 | 1.0 | False | None | None | False | None | False | 994.42 | 0 |
3885493 | 149276 | None | code94 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments to GTP of GROUP-A 4 sqmm. | Mtr | 69.3 | 69.3 | 30.0 | False | None | None | False | None | False | 2079.0 | 0 |
3885494 | 149276 | None | code95 | Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 volts grade, for power factor improvement of rotating machinary capacitor in KVAR. Rating Nos 2 KVAR capacity | Kvar | 528.0 | 528.0 | 1.0 | False | None | None | False | None | False | 528.0 | 0 |
3885495 | 149276 | None | code96 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40 A TPN. | Each | 3348.4 | 3348.4 | 1.0 | False | None | None | False | None | False | 3348.4 | 0 |
3885496 | 149276 | None | code97 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., is to be established through GI wire of size as per ISI specification 7.3.3 of IS 732 using 12 mm dia | Job | 4125.0 | 4125.0 | 1.0 | False | None | None | False | None | False | 4125.0 | 0 |
3885497 | 149276 | None | code98 | Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For Heavy Duty GI pipe: Medium Duty GI pipe of 40mm dia | Mtr | 536.8 | 536.8 | 3.0 | False | None | None | False | None | False | 1610.4 | 0 |
3885498 | 149276 | None | code99 | Providing, Supplying and fixing suitable for 1.1 KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps,bolts,nuts and washers etc. with necessary materials and labour tools and equipments as per instructions of engineer incharge of work. 3.5x6 Sqm | Each | 412.5 | 412.5 | 1.0 | False | None | None | False | None | False | 412.5 | 0 |
3885499 | 149276 | None | code100 | Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work. | Job | 1595.0 | 1595.0 | 1.0 | False | None | None | False | None | False | 1595.0 | 0 |
3885500 | 149276 | None | code101 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 63 A | Nos | 441.1 | 441.1 | 1.0 | False | None | None | False | None | False | 441.1 | 0 |
3885501 | 149276 | None | code102 | Yield testing of borewells at final depth with a minimum of 10 hours continuously with the help of pump testing unit including the cost of transportation charges, crew charges and cost of consumables. | Each | 17936.6 | 17936.6 | 1.0 | False | None | None | False | None | False | 17936.6 | 0 |
3885502 | 149276 | None | code103 | Supply and Assembling of TOTALLY ANTI-CORROSIVE, Bobbin wound FRP fivbre glass Pressure and filter 1200mm diameter Fitted with pressure gauge panel, manual air bleeder water drain and emptying plug with collector arms and diffuser made from unplasticized pvc and polypropylene, including multiport valve -5 valve for filtration, suction, back wash, rinse, close & recirculation. Filtration velocity 40cum/hr/sqm. Maximum working pressure 2.5 kg/cm2, 3 inch connection, Flow rate =43 cum/hrs. | Nos | 536250.0 | 536250.0 | 4.0 | False | None | None | False | None | False | 2145000.0 | 0 |
3885503 | 149276 | None | code104 | Supply and fix pump & motors with 3 HP mono block pump 10-12 mtr head flow rate of 56 cu.mt/ hr with necessary ms base plate, clamps for foundation with nuts & bolts. | Nos | 110000.0 | 110000.0 | 5.0 | False | None | None | False | None | False | 550000.0 | 0 |
3885504 | 149276 | None | code105 | Supply and fixing of SS prefilter with 110mm plange connections flow rate of 56 cu.mt/hr with necessary nuts & bolts. | Nos | 96250.0 | 96250.0 | 5.0 | False | None | None | False | None | False | 481250.0 | 0 |
3885505 | 149276 | None | code106 | Supplying and fixing of floor/Return inlets. Adjustable flow Made in white ABS Plastic, screws in SS 2" external thread and 50mm dia. Solvent Max Flow Rate 5000 Lts/hour. | Nos | 3162.5 | 3162.5 | 55.0 | False | None | None | False | None | False | 173937.5 | 0 |
3885506 | 149276 | None | code107 | Supplying and fixing of Stainless Steel 5 Steps Ladder 40mm dia SS 316 Grade Steps and rails complete with fixing anchors and earth connections Mixed Model Deluxe Model Steps | Nos | 66000.0 | 66000.0 | 4.0 | False | None | None | False | None | False | 264000.0 | 0 |
3885507 | 149276 | None | code108 | Supplying and fixing of Stainless Steel 3 Steps Ladder 40mm dia SS 316 Grade Steps and rails complete with fixing anchors and earth connections Mixed Model Deluxe Model Steps | Nos | 57750.0 | 57750.0 | 4.0 | False | None | None | False | None | False | 231000.0 | 0 |
3885508 | 149276 | None | code109 | Grating: Supply and fixing grating in White ABS Plastic 295 mm wide and 25mm high, UV protected Exclusive of GST | Rmtr | 5500.0 | 5500.0 | 160.0 | False | None | None | False | None | False | 880000.0 | 0 |
3885509 | 149276 | None | code110 | Supplying and Assembling of cleaning equipments like Algae brush, shallow net, deep net wall brush, floor brush, test kit etc., complete Make: Certikin/ Aqvastar Exclusive of GST | Set | 49500.0 | 49500.0 | 1.0 | False | None | None | False | None | False | 49500.0 | 0 |
3885510 | 149276 | None | code111 | Supplying and fixing of 450 mm x 450 mm SS 316 Grade Heavy Duty suction drain grill with frame 14 guage Make: Customize Exclusive of GST | Nos | 46750.0 | 46750.0 | 4.0 | False | None | None | False | None | False | 187000.0 | 0 |
3885511 | 149276 | None | code112 | Supplying of Silicon Sand Coarse grade 0.4 to 0.8 mm Exclusive of GST | Kg | 35.75 | 35.75 | 4000.0 | False | None | None | False | None | False | 143000.0 | 0 |
3885512 | 149276 | None | code113 | Supplying of Silicon Sand Coarse grade 1.0 mm to 2.0 mm Exclusive of GST | Kg | 35.75 | 35.75 | 1000.0 | False | None | None | False | None | False | 35750.0 | 0 |
3885513 | 149276 | None | code114 | Supplying of depth marking tiles and safety signages Exclusive of GST | Nos | 893.75 | 893.75 | 100.0 | False | None | None | False | None | False | 89375.0 | 0 |
3885514 | 149276 | None | code115 | Supply of Lane hooks/anchor cups in SS 316 grade 100mm x 100mm Make: Customize Exclusive of GST | Nos | 8250.0 | 8250.0 | 16.0 | False | None | None | False | None | False | 132000.0 | 0 |
3885515 | 149276 | None | code116 | Supply of Trolly mount suction sweeper. Heavy duty including 3 HP self priming pump (Kirloskar Make) 1 no SS Vaccum head 1 No SS pre filter - 1 No and rope 30 mtr long and hose pipe 75 mm 30 mtr long Exclusive of GST | Set | 233750.0 | 233750.0 | 1.0 | False | None | None | False | None | False | 233750.0 | 0 |
3885516 | 149276 | None | code117 | Supplying and erection of control panel with 3 phase for providing power supply to filters pumps 3 HP - 3 Nos and including starter, ammeter, voltmeter, ELCB, selector switch etc for complete unit Exclusive of GST | Nos | 206250.0 | 206250.0 | 1.0 | False | None | None | False | None | False | 206250.0 | 0 |
3885517 | 149276 | None | code118 | Provide and fixing of puddle pipe 750mm long using PVC 10kg/ cm² grade Make: Astral/supreme/Finolex/Ashrivad 63mm (2") Dia Exclusive of GST | Nos | 2337.5 | 2337.5 | 4.0 | False | None | None | False | None | False | 9350.0 | 0 |
3885518 | 149276 | None | code119 | Provide and fixing of puddle pipe 750mm long using PVC 10kg/ cm² grade Make: Astral/supreme/Finolex/Ashrivad 75mm (2.5") Dia Exclusive of GST | Nos | 2887.5 | 2887.5 | 4.0 | False | None | None | False | None | False | 11550.0 | 0 |
3885519 | 149276 | None | code120 | Provide and fixing of puddle pipe 750mm long using PVC 10kg/ cm² grade Make: Astral/supreme/Finolex/Ashrivad 90mm (3") Dia Exclusive of GST | Nos | 4812.5 | 4812.5 | 4.0 | False | None | None | False | None | False | 19250.0 | 0 |
3885520 | 149276 | None | code121 | Provide and fixing of puddle pipe 750mm long using PVC 10kg/ cm² grade Make: Astral/supreme/Finolex/Ashrivad 110mm (4") Dia Exclusive of GST | Nos | 6050.0 | 6050.0 | 12.0 | False | None | None | False | None | False | 72600.0 | 0 |
3885521 | 149276 | None | code122 | Provide and fixing of puddle pipe 750mm long using PVC 10kg/ cm² grade Make: Astral/supreme/Finolex/Ashrivad 160mm (6") Dia Exclusive of GST | Nos | 9625.0 | 9625.0 | 14.0 | False | None | None | False | None | False | 134750.0 | 0 |
3885522 | 149276 | None | code123 | Provide and fixing of dia NON Return / check Valves including all necessary fittings, Make: Aqvaatar/Equivalent 110mm (4") Dia Exclusive of GST | Nos | 26125.0 | 26125.0 | 4.0 | False | None | None | False | None | False | 104500.0 | 0 |
3885523 | 149276 | None | code124 | Providing and laying PVC 10 Kg/cm2 pipes and specials fixing in position using solvent cement and pressure checking at 3kg/cm2 at all joints about 24 hours continously also including necessary roof / wall/floor/anchoring with clamp and bolts duly painted Make: Astral/supreme/Finolex with ISI Mark 63mm (2") Dia Exclusive of GST | Rmtr | 1265.0 | 1265.0 | 90.0 | False | None | None | False | None | False | 113850.0 | 0 |
3885524 | 149276 | None | code125 | Providing and laying PVC 10 Kg/cm2 pipes and specials fixing in position using solvent cement and pressure checking at 3kg/cm2 at all joints about 24 hours continously also including necessary roof / wall/floor/anchoring with clamp and bolts duly painted Make: Astral/supreme/Finolex with ISI Mark 75mm (2.5") Dia Exclusive of GST | Rmtr | 1848.0 | 1848.0 | 90.0 | False | None | None | False | None | False | 166320.0 | 0 |
3885525 | 149276 | None | code126 | Providing and laying PVC 10 Kg/cm2 pipes and specials fixing in position using solvent cement and pressure checking at 3kg/cm2 at all joints about 24 hours continously also including necessary roof / wall/floor/anchoring with clamp and bolts duly painted Make: Astral/supreme/Finolex with ISI Mark 90mm (3") Dia Exclusive of GST | Rmtr | 2640.0 | 2640.0 | 110.0 | False | None | None | False | None | False | 290400.0 | 0 |
3885526 | 149276 | None | code127 | Providing and laying PVC 10 Kg/cm2 pipes and specials fixing in position using solvent cement and pressure checking at 3kg/cm2 at all joints about 24 hours continously also including necessary roof / wall/floor/anchoring with clamp and bolts duly painted Make: Astral/supreme/Finolex with ISI Mark 110mm (4") Dia Exclusive of GST | Rmtr | 4015.0 | 4015.0 | 110.0 | False | None | None | False | None | False | 441650.0 | 0 |
3885527 | 149276 | None | code128 | Providing and laying PVC 10 Kg/cm2 pipes and specials fixing in position using solvent cement and pressure checking at 3kg/cm2 at all joints about 24 hours continously also including necessary roof / wall/floor/anchoring with clamp and bolts duly painted Make: Astral/supreme/Finolex with ISI Mark 160mm (6") Dia Exclusive of GST | Rmtr | 8525.0 | 8525.0 | 260.0 | False | None | None | False | None | False | 2216500.0 | 0 |
3885528 | 149276 | None | code129 | Supply of Back stroke indicator pipe 2m high with Deck sleeve dia, 450mm long below GL as per drawing in SS 304 grade Exclusive of GST | Nos | 39875.0 | 39875.0 | 8.0 | False | None | None | False | None | False | 319000.0 | 0 |
3885529 | 149276 | None | code130 | Supply and fixing of Grab rail 43 mm dia 1.5 mtr long in SS 316 grade Exclusive of GST | Nos | 17875.0 | 17875.0 | 20.0 | False | None | None | False | None | False | 357500.0 | 0 |
3885530 | 149276 | None | code131 | Supply of start up chemicals for pool commissioning and operation including chlorine, muriatic aacid, alum and soda ash and maintainence and training for 1 month Exclusive of GST | Nos | 96250.0 | 96250.0 | 1.0 | False | None | None | False | None | False | 96250.0 | 0 |
3885531 | 149276 | None | code132 | Supply and fixing of SS starting blocks (Make Indian) Exclusive of GST | Nos | 165000.0 | 165000.0 | 6.0 | False | None | None | False | None | False | 990000.0 | 0 |
3885532 | 149276 | None | code133 | Supplying of antiwave lanes 110mm dia 25m length Exclusive of GST | Nos | 68750.0 | 68750.0 | 10.0 | False | None | None | False | None | False | 687500.0 | 0 |
3885533 | 149276 | None | code134 | Supplying of MS Powder quoted lane winders Exclusive of GST | Nos | 96250.0 | 96250.0 | 3.0 | False | None | None | False | None | False | 288750.0 | 0 |
3885534 | 149276 | None | code135 | Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for:Pipes of SN 8, 200mm dia. | m | 1137.4 | 1137.4 | 90.0 | False | None | None | False | None | False | 102366.0 | 0 |
3885535 | 149276 | None | code136 | Providing and fixing Wafer type single flange Butterfly valve conforming to relevant IS 13099/9991 EN GGG40/50 with latest amendments as detailed below of the following diameter and types with TP set and conveying to work site, loading and unloading, stacking etc. with all lead and lift. The rate is inclusive of the cost of valve, TP set, rubber insertion, bolts and nuts and excluding earth work excavation.For PN 10.0 (Note: TP set should be considered only for DI pipes estimate. For MS pipes estimates, TP sets cost of corresponding dia shall be deducted from the SR rates of valves and provision for corresponding dia MS flanges should be made in the estimate.For Valve of PN 10.00 and 100MM | Each | 6433.9 | 6433.9 | 14.0 | False | None | None | False | None | False | 90074.6 | 0 |
3885536 | 149276 | None | code137 | For Valve of PN 10.00 and 150MM | Each | 13808.3 | 13808.3 | 14.0 | False | None | None | False | None | False | 193316.2 | 0 |
3885537 | 149276 | None | code138 | For Valve of PN 10.00 and 200MM | Each | 15368.1 | 15368.1 | 6.0 | False | None | None | False | None | False | 92208.6 | 0 |
3885538 | 149276 | None | code139 | Steel Almirah with Shelves & Locker Glass Door 6.6 Feet 18x20 Gauge Size: 198cm H x 91.5cm W x 48cm D. Size: 78"x36"x19" | Nos | 10324.0 | 10324.0 | 15.0 | False | None | None | False | None | False | 154860.0 | 0 |
3885539 | 149276 | None | code140 | Steel Tubular Table (With one shelf and 3 Drawers) (Steel Top) Size: 4.5L x 2.5W x 2.5H, Size: 54" x 30" x 30" | Nos | 5984.0 | 5984.0 | 15.0 | False | None | None | False | None | False | 89760.0 | 0 |
3885540 | 149276 | None | code141 | Computer Table with Three drawers with Sliding key Board Size: 48"x24"x30" (4'x2'x2.5') | Nos | 7960.0 | 7960.0 | 3.0 | False | None | None | False | None | False | 23880.0 | 0 |
3885541 | 149276 | None | code142 | Computer Room Chair with PU Arm Hand Rest Size: 82 to 92cms H x 65cm W x 65cm D | Nos | 4152.0 | 4152.0 | 3.0 | False | None | None | False | None | False | 12456.0 | 0 |
3885542 | 149276 | None | code143 | Three Seater Perforated Chair | Nos | 6750.0 | 6750.0 | 3.0 | False | None | None | False | None | False | 20250.0 | 0 |
3885543 | 149276 | None | code144 | Supply and installation of Treadmill of Speed: 0.5 25km / h (0.3 15mi /h), AC3Hp (10.5Hp max) Power of the motor. Incline Rate : 0% 16%, Input power : 120V or 220V, 50Hz 60Hz Features : self tracking roller, antiskid grippers, USB socket, shock absorption system, convenience function, wireless mobile recharger , wireless heart measurement, pre-lubricated deck, Running area W530 X L1600mm (21inchs x63inchs), maximum user weight 200kgs. Display info : time, distance, calory, speed, incline, heart rate. Inclusive of all taxes and Transportation. | Nos | 678895.0 | 678895.0 | 2.0 | False | None | None | False | None | False | 1357790.0 | 0 |
3885544 | 149276 | None | code145 | Supply and installation of Elliptical of Resistance Level: 20 Levels, Power Requirements : 120 volts, Set up height : 4, 10 Workout Programs :Manual, random, interval, custom interval, 10K Features : Heart rate monitoring, space-efficient footprint, patented MultiGrip handlebars, water bottle holder, Workout boosters X-Mode, ArmBlaster, GluteKicker, Dedicated logic programming, quick start, auto quick start, cool down, heart logic intelligence, wireless & Digital heart rate, Heart rate-controlled programs, maximum user weight 180kgs. Inclusive of all taxes and transportation | Nos | 270174.0 | 270174.0 | 3.0 | False | None | None | False | None | False | 810522.0 | 0 |
3885545 | 149276 | None | code146 | Supply and installation of Bike H775 Technical specifications:- resistance level : 8 levels, no-friction magnetic resistance. Powe r:1.5 volts x2, aa size battery. Fly wheel : 5 kgs precision balanced Drive syatem : center design drive, super silent poly-v belt driven. Pedals : self balanced with adjustable straps.Seat : ergonomically designed easy seat with flex back cushion contoures for lumbar support with horizontal slide adjustment handle bars :side handle bar with contact heart rate sensor and u bar style front Handle. display : Icd display, single window computerized console.Display : multi read out instantly displays time, speed, distance, calories, pulse, odo and scan. user weight : 100 kgs.Frame structure : extra sturdy and stable steel frame construction for maximum durability and stability, frame to be finished with proprietary two coat powder process. Inclusive of all taxes and Transportation. | Nos | 264631.0 | 264631.0 | 1.0 | False | None | None | False | None | False | 264631.0 | 0 |
3885546 | 149276 | None | code147 | Supply and installation of BH H772 Upright Bike : 130 x 62 x 142 cm Weight LED 64.6 kg / TV 67 kg Resistance system Electromagnetic brake Intensity 24 levels Power 250 w,Self generating LED Yes / TV No,Transmission system Poly-V belt,Type of monitor LED / SmartFocus,Vertical Saddle adjustment Yes,Horizontal saddle adjustment Yes,In-built fan No,Heart rate sensor on handrails Yes,Wireless chest strap Optional Bottle holder Yes,Wheels for transport Yes. Inclusive of all taxes and Transportation. | Nos | 202283.0 | 202283.0 | 1.0 | False | None | None | False | None | False | 202283.0 | 0 |
3885547 | 149276 | None | code148 | Supply and installation of Lexco Seated Chest Press : Product size: W1,437 L1,430 H1,940mm (56.6 " 56.3" 76.4 "),Weight: 282kg (622lb) ,block weight: 100kg (220lb) Material: involute pipe 50 X 105 3.0T,outer cover : ABS material double sided block cover urethane foam (memory foam) sheet Characteristic Improved muscle handle angle implementing the shrinkage start bar to control the movement start position to expand the range of motion step 10 the gas spring absorber + rack gear type elevator saddle ABS material covers both sides of the block. Inclusive of all taxes and Transportation. | Nos | 433988.0 | 433988.0 | 2.0 | False | None | None | False | None | False | 867976.0 | 0 |
3885548 | 149276 | None | code149 | Supply and installation of Olympic Plates -Olympic Rubberised Plates with 51mm diameter with top quality rubber coating for safety and Metal Ring for Durability. : 10kgs-8 nos,15 kgs 6 nos, 20kgs-4 nos , 25 kgs - 4 nos(270 kgs). Inclusive of all taxes and Transportation. | Nos | 117801.0 | 117801.0 | 2.0 | False | None | None | False | None | False | 235602.0 | 0 |
3885549 | 149276 | None | code150 | Supply and installation of Rubberised Hex Dumbells- Solid steel head, pressed and welded to a chrome handle with quality knurling for better grip.Rubber coating. Weight indicators permanently moulded into the heads: 2.5-6nos,5-6nos,10-4nos,12.5-4nos,15-4nos,17.5-2nos,20-2nos,22.5-2nos,25-2nos,27.5-2nos,30-2nos(480 kgs) Inclusive of all taxes and Transportation. | Nos | 177480.0 | 177480.0 | 1.0 | False | None | None | False | None | False | 177480.0 | 0 |
3885550 | 149276 | None | code151 | Supply and installation of Two Tier Dumbell Rack : Dumbells Rack , Two Tier Dumbell Storage rack , heavy duty made in steel 12 gauge pipes with 3 coates of Lycra. Inclusive of all taxes and Transportation. | Nos | 31174.0 | 31174.0 | 1.0 | False | None | None | False | None | False | 31174.0 | 0 |
3885551 | 149276 | None | code152 | Supply and installation of Swiss ball - Quality, Safety, Durability Anti-Burst Gym Ball made with the highest quality PVC material available - Fitness balls anti-slip matte surface, anti-burst design ensures safe use. set 3 balls 55cms(1200)65cms(1400)75cms (1750), Inclusive of all taxes and Transportation. | Nos | 6027.0 | 6027.0 | 2.0 | False | None | None | False | None | False | 12054.0 | 0 |
3885552 | 149276 | None | code153 | Supply and installation of Three Fold Excrcise Mats: Foldable Exercise mats made with high quality anti sweat absorbing resin . Inclusive of all taxes and Transportation. | Nos | 5067.0 | 5067.0 | 3.0 | False | None | None | False | None | False | 15201.0 | 0 |
3885553 | 149276 | None | code154 | Providing & constructing standard rubber flooring for indoor areas using rubber membrane 12 to 16 mm thick, to be layed over cement mortar using 1;6 beneath rubber membrane including cost of all materials ,labour ,packing joints and mortar, finishing,curing all lead and lift as per direction of engineer incharge of work | Sqm | 4882.0 | 4882.0 | 150.0 | False | None | None | False | None | False | 732300.0 | 0 |
3885554 | 149276 | None | code155 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid | Each | 5321.8 | 5321.8 | 8.0 | False | None | None | False | None | False | 42574.4 | 0 |
3885555 | 149276 | None | code156 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps | Each | 3390.2 | 3390.2 | 8.0 | False | None | None | False | None | False | 27121.6 | 0 |
3885556 | 149276 | None | code157 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern | Unit | 4899.4 | 4899.4 | 5.0 | False | None | None | False | None | False | 24497.0 | 0 |
3885557 | 149276 | None | code158 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. | Each | 1342.0 | 1342.0 | 4.0 | False | None | None | False | None | False | 5368.0 | 0 |
3885558 | 149276 | None | code159 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. | Unit | 545.6 | 545.6 | 12.0 | False | None | None | False | None | False | 6547.2 | 0 |
3885559 | 149276 | None | code160 | Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 g | Nos | 182.6 | 182.6 | 75.0 | False | None | None | False | None | False | 13695.0 | 0 |
3885560 | 149276 | None | code161 | Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. | Nos | 891.0 | 891.0 | 80.0 | False | None | None | False | None | False | 71280.0 | 0 |
3885561 | 149276 | None | code162 | Providing and fixing PTMT, push cock of approved quality and colour.15 mm nominal bore, 98 mm long, weighing not less than 75 gms | Nos | 140.8 | 140.8 | 85.0 | False | None | None | False | None | False | 11968.0 | 0 |
3885562 | 149276 | None | code163 | Providing and fixing in position brass stop cock of approved quality of as per dia nominal bore including cost of all materials,labour and HOM of equipments with all leads complete as per specifications. 15 Nominal Bore | Nos | 328.9 | 328.9 | 100.0 | False | None | None | False | None | False | 32890.0 | 0 |
3885563 | 149276 | None | code164 | 20 Nominal Bore | Nos | 335.5 | 335.5 | 110.0 | False | None | None | False | None | False | 36905.0 | 0 |
3885564 | 149276 | None | code165 | Providing and fixing in position brass bib cock of approved quality of as per dia nominal bore including cost of all materials,labour and HOM of equipments with all leads complete as per specifications. | Nos | 335.5 | 335.5 | 150.0 | False | None | None | False | None | False | 50325.0 | 0 |
3885565 | 149276 | None | code166 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g. | Nos | 110.0 | 110.0 | 12.0 | False | None | None | False | None | False | 1320.0 | 0 |
3885566 | 149276 | None | code167 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. | Sqm | 3067.9 | 3067.9 | 4.2 | False | None | None | False | None | False | 12885.18 | 0 |
3885567 | 149276 | None | code168 | Providing and fixing bright finished brass hard drawn hooks and eyes :300mm | Each | 92.4 | 92.4 | 12.0 | False | None | None | False | None | False | 1108.8 | 0 |
3885568 | 149276 | None | code169 | Providing & fixing Chorinated Poly Venyl(CPVC) pipes confirming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete.(External work and Burried). 25mm.dia.. | Mtr | 325.6 | 325.6 | 150.0 | False | None | None | False | None | False | 48840.0 | 0 |
3885569 | 149276 | None | code170 | 32mm.dia.. | Mtr | 409.2 | 409.2 | 175.0 | False | None | None | False | None | False | 71610.0 | 0 |
3885570 | 149276 | None | code171 | 40mm.dia.. | Mtr | 524.7 | 524.7 | 190.0 | False | None | None | False | None | False | 99693.0 | 0 |
3885571 | 149276 | None | code172 | Providing & fixing Chorinated Poly Venyl(CPVC) pipes confirming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete.(Concealed work including cutting chasing and good the walls etc). 15mm.dia.. | Mtr | 339.9 | 339.9 | 120.0 | False | None | None | False | None | False | 40788.0 | 0 |
3885572 | 149276 | None | code173 | 20mm.dia.. | Mtr | 416.9 | 416.9 | 135.0 | False | None | None | False | None | False | 56281.5 | 0 |
3885573 | 149276 | None | code174 | 25mm.dia.. | Mtr | 524.7 | 524.7 | 150.0 | False | None | None | False | None | False | 78705.0 | 0 |
3885574 | 149276 | None | code175 | Providing and fixing water meter with stop cock, jam nut, socket in G.I pipe line including cutting and threading the pipe and making long screws including cost of all materials, labour , HOM of equipments and testing complete as per specifications. | Set | 1452.0 | 1452.0 | 1.0 | False | None | None | False | None | False | 1452.0 | 0 |
3885575 | 149276 | None | code176 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : | Nos | 365.2 | 365.2 | 150.0 | False | None | None | False | None | False | 54780.0 | 0 |
3885576 | 149276 | None | code177 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :32mm.dia.. | Nos | 657.8 | 657.8 | 175.0 | False | None | None | False | None | False | 115115.0 | 0 |
3885577 | 149276 | None | code178 | 40mm.dia.. | Nos | 772.2 | 772.2 | 190.0 | False | None | None | False | None | False | 146718.0 | 0 |
3885578 | 149276 | None | code179 | Providing and fixing gun metal non- return valve of approved quality (screwedend): 40 mm nominal bore ,Vertical. | Each | 1347.5 | 1347.5 | 145.0 | False | None | None | False | None | False | 195387.5 | 0 |
3885579 | 149276 | None | code180 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for::a.PVC pipes 75mm dia., 6 kg/sqcm & class 3 b.PVC pipes 110mm dia., 6 kg/sqcm & class 3. BWSSB-SR-2023-2024 75mm.dia.. | Mtr | 242.0 | 242.0 | 160.0 | False | None | None | False | None | False | 38720.0 | 0 |
3885580 | 149276 | None | code181 | 110mm.dia.. | Mtr | 452.1 | 452.1 | 40.0 | False | None | None | False | None | False | 18084.0 | 0 |
3885581 | 149276 | None | code182 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors :*100 mm inlet and 100 mm outlet* Sand Cast Iron S&S as per IS:3989 | Each | 1531.2 | 1531.2 | 100.0 | False | None | None | False | None | False | 153120.0 | 0 |
3885582 | 149276 | None | code183 | Providing and fixing PTMT grating of approved quality and colour. | Nos | 48.4 | 48.4 | 115.0 | False | None | None | False | None | False | 5566.0 | 0 |
3885583 | 149276 | None | code184 | Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in- charge. | Each | 85.8 | 85.8 | 105.0 | False | None | None | False | None | False | 9009.0 | 0 |
3885584 | 149276 | None | code185 | Providing and constructing “WIRE CUT BRICK MACHINEHOLE CHAMBERS” using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber. Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Supplying and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Supplying and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, dewatering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm diaCirc. B M.H: Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.0 M depth & SFRC cover & frame. BWSSB-2023-24 | Nos | 31951.7 | 31951.7 | 5.0 | False | None | None | False | None | False | 159758.5 | 0 |
3885585 | 149276 | None | code186 | Open Conduit System Supplying heavy gauge PVC conduit pipe ....... dia ....... mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25 mm dia 2 mm thick | m | 81.0 | 81.0 | 150.0 | False | None | None | False | None | False | 12150.0 | 0 |
3885586 | 149276 | None | code187 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused
ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire
wherever necessary 19/20 mm dia 2 mm thick | m | 66.0 | 66.0 | 450.0 | False | None | None | False | None | False | 29700.0 | 0 |
3885587 | 149276 | None | code188 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused
ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire
wherever necessary 25 mm dia 2 mm thick | m | 78.0 | 78.0 | 300.0 | False | None | None | False | None | False | 23400.0 | 0 |
3885588 | 149276 | None | code189 | Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused
ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire
wherever necessary 32 mm dia 2.5 mm thick | m | 103.0 | 103.0 | 100.0 | False | None | None | False | None | False | 10300.0 | 0 |
3885589 | 149276 | None | code190 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm dia 2 mm thick | m | 68.0 | 68.0 | 150.0 | False | None | None | False | None | False | 10200.0 | 0 |
3885590 | 149276 | None | code191 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thick | m | 79.0 | 79.0 | 100.0 | False | None | None | False | None | False | 7900.0 | 0 |
3885591 | 149276 | None | code192 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 32 mm dia 2.5 mm thick | m | 99.0 | 99.0 | 70.0 | False | None | None | False | None | False | 6930.0 | 0 |
3885592 | 149276 | None | code193 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm .... etc. as required. 25 mm | m | 35.0 | 35.0 | 15.32 | False | None | None | False | None | False | 536.2 | 0 |
3885593 | 149276 | None | code194 | Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 25 mm | m | 22.0 | 22.0 | 25.0 | False | None | None | False | None | False | 550.0 | 0 |
3885594 | 149276 | None | code195 | Supplying PVC/GI flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely 32 mm | m | 29.0 | 29.0 | 15.0 | False | None | None | False | None | False | 435.0 | 0 |
3885595 | 149276 | None | code196 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc. 200 x 90 x 65 mm | No | 161.0 | 161.0 | 5.0 | False | None | None | False | None | False | 805.0 | 0 |
3885596 | 149276 | None | code197 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switch box | Point | 269.0 | 269.0 | 10.0 | False | None | None | False | None | False | 2690.0 | 0 |
3885597 | 149276 | None | code198 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3m upto 6m from tapping point to out let via switch box | Point | 379.0 | 379.0 | 15.0 | False | None | None | False | None | False | 5685.0 | 0 |
3885598 | 149276 | None | code199 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6m upto 10m from tapping point to out let via switch box | Point | 555.0 | 555.0 | 35.0 | False | None | None | False | None | False | 19425.0 | 0 |
3885599 | 149276 | None | code200 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3m upto 6m from tapping point to out let via switches | Point | 677.0 | 677.0 | 5.0 | False | None | None | False | None | False | 3385.0 | 0 |
3885600 | 149276 | None | code201 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6m upto 10m from tapping point to out let via switches box | Point | 989.0 | 989.0 | 5.0 | False | None | None | False | None | False | 4945.0 | 0 |
3885601 | 149276 | None | code202 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1 mm2 | m | 19.0 | 19.0 | 750.0 | False | None | None | False | None | False | 14250.0 | 0 |
3885602 | 149276 | None | code203 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 mm2 | m | 26.0 | 26.0 | 850.0 | False | None | None | False | None | False | 22100.0 | 0 |
3885603 | 149276 | None | code204 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 mm2 | m | 45.0 | 45.0 | 450.0 | False | None | None | False | None | False | 20250.0 | 0 |
3885604 | 149276 | None | code205 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 mm2 | m | 63.0 | 63.0 | 300.0 | False | None | None | False | None | False | 18900.0 | 0 |
3885605 | 149276 | None | code206 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 mm2 | m | 92.0 | 92.0 | 155.0 | False | None | None | False | None | False | 14260.0 | 0 |
3885606 | 149276 | None | code207 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 10 mm2 | m | 167.0 | 167.0 | 50.0 | False | None | None | False | None | False | 8350.0 | 0 |
3885607 | 149276 | None | code208 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in
Brick/Stone/C.C wall 1-2 Way | Each | 138.0 | 138.0 | 6.0 | False | None | None | False | None | False | 828.0 | 0 |
3885608 | 149276 | None | code209 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in
Brick/Stone/C.C wall 3 Way | Each | 159.0 | 159.0 | 10.0 | False | None | None | False | None | False | 1590.0 | 0 |
3885609 | 149276 | None | code210 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in
Brick/Stone/C.C wall 4-5 Way | Each | 177.0 | 177.0 | 5.0 | False | None | None | False | None | False | 885.0 | 0 |
3885610 | 149276 | None | code211 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in
Brick/Stone/C.C wall 6 Way | Each | 220.0 | 220.0 | 6.0 | False | None | None | False | None | False | 1320.0 | 0 |
3885611 | 149276 | None | code212 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in
Brick/Stone/C.C wall 8 Way | Each | 261.0 | 261.0 | 4.0 | False | None | None | False | None | False | 1044.0 | 0 |
3885612 | 149276 | None | code213 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in
Brick/Stone/C.C wall 10-12 Way | Each | 319.0 | 319.0 | 5.0 | False | None | None | False | None | False | 1595.0 | 0 |
3885613 | 149276 | None | code214 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in
Brick/Stone/C.C wall 16 Way | Each | 363.0 | 363.0 | 2.0 | False | None | None | False | None | False | 726.0 | 0 |
3885614 | 149276 | None | code215 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in
Brick/Stone/C.C wall 18 Way | Each | 405.0 | 405.0 | 2.0 | False | None | None | False | None | False | 810.0 | 0 |
3885615 | 149276 | None | code216 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on
the existing metal/PVC box. 1-2 Module | Each | 137.0 | 137.0 | 6.0 | False | None | None | False | None | False | 822.0 | 0 |
3885616 | 149276 | None | code217 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on
the existing metal/PVC box. 3 Module | Each | 161.0 | 161.0 | 10.0 | False | None | None | False | None | False | 1610.0 | 0 |
3885617 | 149276 | None | code218 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on
the existing metal/PVC box. 4 Module | Each | 175.0 | 175.0 | 5.0 | False | None | None | False | None | False | 875.0 | 0 |
3885618 | 149276 | None | code219 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on
the existing metal/PVC box. 6 Module | Each | 234.0 | 234.0 | 6.0 | False | None | None | False | None | False | 1404.0 | 0 |
3885619 | 149276 | None | code220 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on
the existing metal/PVC box. 8 Module | Each | 284.0 | 284.0 | 4.0 | False | None | None | False | None | False | 1136.0 | 0 |
3885620 | 149276 | None | code221 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on
the existing metal/PVC box. 10-12 Module | Each | 344.0 | 344.0 | 5.0 | False | None | None | False | None | False | 1720.0 | 0 |
3885621 | 149276 | None | code222 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on
the existing metal/PVC box. 16 Module | Each | 397.0 | 397.0 | 2.0 | False | None | None | False | None | False | 794.0 | 0 |
3885622 | 149276 | None | code223 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on
the existing metal/PVC box. 18 Module | Each | 457.0 | 457.0 | 2.0 | False | None | None | False | None | False | 914.0 | 0 |
3885623 | 149276 | None | code224 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A One Way Switch | Each | 102.0 | 102.0 | 90.0 | False | None | None | False | None | False | 9180.0 | 0 |
3885624 | 149276 | None | code225 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Three Way socket | Each | 171.0 | 171.0 | 20.0 | False | None | None | False | None | False | 3420.0 | 0 |
3885625 | 149276 | None | code226 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator Two Module | Each | 357.0 | 357.0 | 20.0 | False | None | None | False | None | False | 7140.0 | 0 |
3885626 | 149276 | None | code227 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way Switch | Each | 180.0 | 180.0 | 5.0 | False | None | None | False | None | False | 900.0 | 0 |
3885627 | 149276 | None | code228 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6A Bell Push | Each | 177.0 | 177.0 | 1.0 | False | None | None | False | None | False | 177.0 | 0 |
3885628 | 149276 | None | code229 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP Switch | Each | 326.0 | 326.0 | 5.0 | False | None | None | False | None | False | 1630.0 | 0 |
3885629 | 149276 | None | code230 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal Socket | Each | 236.0 | 236.0 | 10.0 | False | None | None | False | None | False | 2360.0 | 0 |
3885630 | 149276 | None | code231 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. TV/Telephone Socket | Each | 156.0 | 156.0 | 1.0 | False | None | None | False | None | False | 156.0 | 0 |
3885631 | 149276 | None | code232 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. RJ45/I.O Outlet Cat-6 | Each | 337.0 | 337.0 | 5.0 | False | None | None | False | None | False | 1685.0 | 0 |
3885632 | 149276 | None | code233 | Extra for supplying 4 mm thick white plastic plate and covering for junction boxes of size ...... mm conduit using necessary machine screws. 80 mm | No | 15.0 | 15.0 | 7.0 | False | None | None | False | None | False | 105.0 | 0 |
3885633 | 149276 | None | code234 | Extra for supplying 4 mm thick white plastic plate and covering for junction boxes of size ...... mm conduit using necessary machine screws. 110 mm | No | 21.0 | 21.0 | 20.0 | False | None | None | False | None | False | 420.0 | 0 |
3885634 | 149276 | None | code235 | Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 2' - 9/10 W | Each | 551.0 | 551.0 | 2.0 | False | None | None | False | None | False | 1102.0 | 0 |
3885635 | 149276 | None | code236 | Supplying of .....feet -PVC Batten with integrated LED tube .... W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor grater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 20/22 W | Each | 690.0 | 690.0 | 30.0 | False | None | None | False | None | False | 20700.0 | 0 |
3885636 | 149276 | None | code237 | Supply of round/square recess/surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80. Power Input: 220-240V @50/60Hz & Power factor greater than 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W | Each | 1324.0 | 1324.0 | 15.0 | False | None | None | False | None | False | 19860.0 | 0 |
3885637 | 149276 | None | code238 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA. On wall/ ceiling / Rafter / Girders | Each | 122.0 | 122.0 | 47.0 | False | None | None | False | None | False | 5734.0 | 0 |
3885638 | 149276 | None | code239 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE star rated and IS:374/79 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 4.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturerWarranty 48" Sweep BEE Star Rated (1200 mm) | Each | 2677.0 | 2677.0 | 20.0 | False | None | None | False | None | False | 53540.0 | 0 |
3885639 | 149276 | None | code240 | Supplying wall mounting fan suitable to operate at single phase 230v AC. supply. 300 mm Sweep | Each | 2492.0 | 2492.0 | 2.0 | False | None | None | False | None | False | 4984.0 | 0 |
3885640 | 149276 | None | code241 | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. | Each | 171.0 | 171.0 | 5.0 | False | None | None | False | None | False | 855.0 | 0 |
3885641 | 149276 | None | code242 | Fixing a ceiling /wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. | Each | 315.0 | 315.0 | 17.0 | False | None | None | False | None | False | 5355.0 | 0 |
3885642 | 149276 | None | code243 | Extra length of GI pipe of class B 19mm dia for down rod. | m | 197.0 | 197.0 | 50.0 | False | None | None | False | None | False | 9850.0 | 0 |
3885643 | 149276 | None | code244 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300 mm) | Each | 2969.0 | 2969.0 | 8.0 | False | None | None | False | None | False | 23752.0 | 0 |
3885644 | 149276 | None | code245 | Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. | Each | 707.0 | 707.0 | 8.0 | False | None | None | False | None | False | 5656.0 | 0 |
3885645 | 149276 | None | code246 | Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greater than 70%. efficacy greater than 80 lumen per W, life greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by ABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 9W, 6500K | Each | 154.0 | 154.0 | 4.0 | False | None | None | False | None | False | 616.0 | 0 |
3885646 | 149276 | None | code247 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of antiglare clear diffuser with Injection moulded polycarbonate /clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency greater than 1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source LED Floodlight 100W | Each | 9486.0 | 9486.0 | 2.0 | False | None | None | False | None | False | 18972.0 | 0 |
3885647 | 149276 | None | code248 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of antiglare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency Grater than 1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source LED Floodlight 70W | Each | 6768.0 | 6768.0 | 2.0 | False | None | None | False | None | False | 13536.0 | 0 |
3885648 | 149276 | None | code249 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of antiglare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency greater than 1301m/w, nominal CRI greater than 75. Luminaire
manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/Lumileds/Osram make LED Source. LED Streetlight 70W | Each | 5992.0 | 5992.0 | 4.0 | False | None | None | False | None | False | 23968.0 | 0 |
3885649 | 149276 | None | code250 | Supplying and Fixing of........mm dia class A GI pipe bracket upto 2ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires. Using 25mm dia G.I.Pipe | Each | 978.0 | 978.0 | 4.0 | False | None | None | False | None | False | 3912.0 | 0 |
3885650 | 149276 | None | code251 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires | Each | 162.0 | 162.0 | 4.0 | False | None | None | False | None | False | 648.0 | 0 |
3885651 | 149276 | None | code252 | Fabricating, supplying and erection of ... ms long hot dip
Galvanized Conical hot dip Pole with BSEN 10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m/s for .......m Pole in single section and single joint welded as per IS 9595/IS10178AWS having dimensions bottom ..... mm , top ... mm with 3 mm thick, suitable base plate and 4Nos of.........long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 6 m - Top 75 mm and Bottom 135 mm dia | Each | 12700.0 | 12700.0 | 4.0 | False | None | None | False | None | False | 50800.0 | 0 |
3885652 | 149276 | None | code253 | Supplying, and fixing of Hot dip Galvanized M.S.Bracket suitable for out door luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete. Single Arm Bracket with 1500 mm Standard 40/50 mm dia | Each | 2100.0 | 2100.0 | 4.0 | False | None | None | False | None | False | 8400.0 | 0 |
3885653 | 149276 | None | code254 | Automatic Switch for Street Light | No | 2303.0 | 2303.0 | 1.0 | False | None | None | False | None | False | 2303.0 | 0 |
3885654 | 149276 | None | code255 | Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 Pair | m | 21.0 | 21.0 | 25.0 | False | None | None | False | None | False | 525.0 | 0 |
3885655 | 149276 | None | code256 | Supplying and fixing of MDF krone junction box with KRONE Module / Telephone cable termination. 10 Pair | Each | 345.0 | 345.0 | 1.0 | False | None | None | False | None | False | 345.0 | 0 |
3885656 | 149276 | None | code257 | Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as per-BS 5514/ISO 3046/ ISO 8528 & IS 1002/ISO 3046 Generator set specifications. 62.5KVA/50kw | Set | 641071.0 | 641071.0 | 1.0 | False | None | None | False | None | False | 641071.0 | 0 |
3885657 | 149276 | None | code258 | Supply, Erection, testing and commissioning of AMF panel suitable for .....kVA DG set. The panel is of cubical type base/floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....A 4 pole contactor for alternator with thermal O/L relay,..... A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start/stop logic, Mains/generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301controller with water temperature/Lube oil pressure/ engine speed, Voltage/ampere/Frequency/ kVA, Running-hour count, No of starts, Fault indication, over / under speed, Fails to start, Low oil pleasure, High engine temperature, Under/over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battery charger unit with inbuilt Auto/Manual and Flat/Boost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules. 62.5 KVA | Set | 77768.0 | 77768.0 | 1.0 | False | None | None | False | None | False | 77768.0 | 0 |
3885658 | 149276 | None | code259 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts | No | 4256.0 | 4256.0 | 18.0 | False | None | None | False | None | False | 76608.0 | 0 |
3885659 | 149276 | None | code260 | GI/Copper strips for grounding connections, using necessary fixing materials as required GI/Copper strips 25 x 6 mm GI strip | Mtr | 128.0 | 128.0 | 70.0 | False | None | None | False | None | False | 8960.0 | 0 |
3885660 | 149276 | None | code261 | GI/Copper strips for grounding connections, using necessary fixing materials as required GI/Copper strips 25 x 6 mm Copper strip | Mtr | 1100.0 | 1100.0 | 25.0 | False | None | None | False | None | False | 27500.0 | 0 |
3885661 | 149276 | None | code262 | GI/Copper strips for grounding connections, using necessary fixing materials as required GI/Copper strips 600 x 600 x 3 mm Copper plate | Each | 7421.0 | 7421.0 | 4.0 | False | None | None | False | None | False | 29684.0 | 0 |
3885662 | 149276 | None | code263 | RCC Pole - 9 Mtr Long, 145 Kg WL
(Dwg No. BESCOM/GM/QS&S/02 Dtd 24.11.2018) as
per IS-785 | No | 7076.0 | 7076.0 | 3.0 | False | None | None | False | None | False | 21228.0 | 0 |
3885663 | 149276 | None | code264 | PSCC Pole - 8 Mtr Long, 140 Kg WL
(Dwg No. BESCOM/GM/QS&S/17 Dtd 24.11.2018) as
per REC Standards | No | 2674.0 | 2674.0 | 23.0 | False | None | None | False | None | False | 61502.0 | 0 |
3885664 | 149276 | None | code265 | 11 kV, Special 3 Pin Cross Arm - GI | No | 1151.0 | 1151.0 | 1.0 | False | None | None | False | None | False | 1151.0 | 0 |
3885665 | 149276 | None | code266 | HT ST Support 50x8 mm Flat - GI | No | 121.0 | 121.0 | 1.0 | False | None | None | False | None | False | 121.0 | 0 |
3885666 | 149276 | None | code267 | Spiral Earth Electrode | No | 239.0 | 239.0 | 26.0 | False | None | None | False | None | False | 6214.0 | 0 |
3885667 | 149276 | None | code268 | Anticlimbing Device GI Barbed wire (12 Mtr/Kg) | No | 89.0 | 89.0 | 26.0 | False | None | None | False | None | False | 2314.0 | 0 |
3885668 | 149276 | None | code269 | Guarding for Road crossing, Telephone Line Crossing,
between HT & LT Line Crossing | No | 93.0 | 93.0 | 5.0 | False | None | None | False | None | False | 465.0 | 0 |
3885669 | 149276 | None | code270 | LT 4 Pin Cross Arm - GI | No | 379.0 | 379.0 | 5.0 | False | None | None | False | None | False | 1895.0 | 0 |
3885670 | 149276 | None | code271 | No. 8 Strain Insulator | No | 27.0 | 27.0 | 20.0 | False | None | None | False | None | False | 540.0 | 0 |
3885671 | 149276 | None | code272 | RCC Pole Clamp - GI | No | 109.0 | 109.0 | 26.0 | False | None | None | False | None | False | 2834.0 | 0 |
3885672 | 149276 | None | code273 | Guy Clamp - GI | No | 115.0 | 115.0 | 6.0 | False | None | None | False | None | False | 690.0 | 0 |
3885673 | 149276 | None | code274 | 11 kV GI Pin for 11 kV Ceramic Shell Insulator | No | 66.0 | 66.0 | 75.0 | False | None | None | False | None | False | 4950.0 | 0 |
3885674 | 149276 | None | code275 | DISC Insulator 45 kN Porcelain | No | 510.0 | 510.0 | 12.0 | False | None | None | False | None | False | 6120.0 | 0 |
3885675 | 149276 | None | code276 | Rabbit ACSR
(6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM | Km | 46234.0 | 46234.0 | 3.045 | False | None | None | False | None | False | 140782.53 | 0 |
3885676 | 149276 | None | code277 | 7/10 SWG Guy Wire
(7/3.251 mm Dia), Std Wt: 680 Kg/KM | MT | 77226.0 | 77226.0 | 0.08 | False | None | None | False | None | False | 6178.08 | 0 |
3885677 | 149276 | None | code278 | PG Clamp Rabbit to Rabbit | No | 102.0 | 102.0 | 16.0 | False | None | None | False | None | False | 1632.0 | 0 |
3885678 | 149276 | None | code279 | 9 kV, 5 kA Lightning Arrester Metal Oxide Ceramic type
with GROUND DISCONNECTOR
(Dwg No. BESCOM/GM/QS&S/26 Dtd 24.10.2007) | Each | 920.0 | 920.0 | 3.0 | False | None | None | False | None | False | 2760.0 | 0 |
3885679 | 149276 | None | code280 | 11 kV, HG Fuse Unit with Solid Core Insulator
(Dwg No. BESCOM/GM/QS&S/21 Dtd 24.11.2018) | Set | 1069.0 | 1069.0 | 1.0 | False | None | None | False | None | False | 1069.0 | 0 |
3885680 | 149276 | None | code281 | For 100/300 kVA 4/5 Star Rated Transformer on
RCC Pole - 9 Mtr Long, 145 Kg WL - GI | Set | 30694.0 | 30694.0 | 1.0 | False | None | None | False | None | False | 30694.0 | 0 |
3885681 | 149276 | None | code282 | Three H Frame with Transformer Seating and Seating
angle support cross arm for 11 Mtr Spun Pole up to and
including 250 kVA (UG Cable)) - GI | Each | 46731.0 | 46731.0 | 1.0 | False | None | None | False | None | False | 46731.0 | 0 |
3885682 | 149276 | None | code283 | 11 kV, 200 Amps Single Break GOS
(Dwg No. BESCOM/GM/QS&S/23 Dtd 24.11.2018) | Set | 9450.0 | 9450.0 | 1.0 | False | None | None | False | None | False | 9450.0 | 0 |
3885683 | 149276 | None | code284 | 11 kV, DOLO Cutout Conventional to Erstwhile KEB
Specification | Set | 5875.0 | 5875.0 | 1.0 | False | None | None | False | None | False | 5875.0 | 0 |
3885684 | 149276 | None | code285 | Transparent Alkathine tube 19 mm dia, 2 mm thick in
coils of 30 Mtr | Coil | 517.0 | 517.0 | 1.0 | False | None | None | False | None | False | 517.0 | 0 |
3885685 | 149276 | None | code286 | Caution/Danger Board | No | 150.0 | 150.0 | 6.0 | False | None | None | False | None | False | 900.0 | 0 |
3885686 | 149276 | None | code287 | Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC supports as per approved
Drawing. Hard Soil | Per Pit | 1132.0 | 1132.0 | 26.0 | False | None | None | False | None | False | 29432.0 | 0 |
3885687 | 149276 | None | code288 | Digging of Pit for GUY SET Hard Soil | Per Pit | 629.0 | 629.0 | 6.0 | False | None | None | False | None | False | 3774.0 | 0 |
3885688 | 149276 | None | code289 | Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth | No | 1113.0 | 1113.0 | 26.0 | False | None | None | False | None | False | 28938.0 | 0 |
3885689 | 149276 | None | code290 | Providing Spiral Earth Electrode type earthing (without
charcoal, salt etc.,) | No | 93.0 | 93.0 | 26.0 | False | None | None | False | None | False | 2418.0 | 0 |
3885690 | 149276 | None | code291 | For Three H Frame without Transformer Seating and
Seating angle support cross arm for 11 Mtr Spun Pole up to and including 250 kVA (UG Cable) (excluding erection of Pole) | No | 2862.0 | 2862.0 | 1.0 | False | None | None | False | None | False | 2862.0 | 0 |
3885691 | 149276 | None | code292 | Fixing of 4 Pin cross arm with Insulator and Braces fixing | No | 160.0 | 160.0 | 5.0 | False | None | None | False | None | False | 800.0 | 0 |
3885692 | 149276 | None | code293 | Fixing of HT/LT Single Top Support | No | 112.0 | 112.0 | 26.0 | False | None | None | False | None | False | 2912.0 | 0 |
3885693 | 149276 | None | code294 | Fixing of GUY Set with break insulator making use of 7/3.15 mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangement as per approved drawing. (Excluding excavation of PIT | No | 266.0 | 266.0 | 5.0 | False | None | None | False | None | False | 1330.0 | 0 |
3885694 | 149276 | None | code295 | Stringing of conductor Rabbit ACSR, binding of conductor on each insulator and dead ending on strain or disc /strain insulator by means of clamps. | Km | 4361.0 | 4361.0 | 3.045 | False | None | None | False | None | False | 13279.245 | 0 |
3885695 | 149276 | None | code296 | Fixing DOLO Cutout/Horn Gap Fuse including fixing of cross arm and wiring | No | 237.0 | 237.0 | 1.0 | False | None | None | False | None | False | 237.0 | 0 |
3885696 | 149276 | None | code297 | Fixing of GOS including wiring (11 kV Single Break 200
Amps) | No | 1104.0 | 1104.0 | 1.0 | False | None | None | False | None | False | 1104.0 | 0 |
3885697 | 149276 | None | code298 | Numbering and Scheduling of Pole | Km | 712.0 | 712.0 | 1.0 | False | None | None | False | None | False | 712.0 | 0 |
3885698 | 149276 | None | code299 | Distribution Transformer - 3 Phase, 11kV/433V - Stacked CRGO Core with Oil as per IS-1180 (Part-1): 2014 B. CABLE ENTRY TYP 63 kVA, Aluminum Wdg, Star 2 (5 Star) | Each | 186170.0 | 186170.0 | 1.0 | False | None | None | False | None | False | 186170.0 | 0 |
3885699 | 149276 | None | code300 | LT Distribution Box for 100/250 kVA DTC with MCCB's
(SMC) | Each | 24428.0 | 24428.0 | 1.0 | False | None | None | False | None | False | 24428.0 | 0 |
3885700 | 149276 | None | code301 | 3 Phase CT/PT operated alternating current Smart
Meter of Accuracy Class 0.2s DLMS with GPRS
Communication Module | Each | 29993.0 | 29993.0 | 1.0 | False | None | None | False | None | False | 29993.0 | 0 |
3885701 | 149276 | None | code302 | LT Metering Cubicle at Low Tension for 50 KW to 150
KW having specification & design as per the prototype
approval
(Excluding Meter Cost & Modem Cost) | Each | 79882.0 | 79882.0 | 1.0 | False | None | None | False | None | False | 79882.0 | 0 |
3885702 | 149276 | None | code303 | Erection of 25 to 63 kVA Transformer on Transformer
Structure | No | 1193.0 | 1193.0 | 1.0 | False | None | None | False | None | False | 1193.0 | 0 |
3885703 | 149276 | None | code304 | Erection of LT metering Cubicle on Platform | No | 1659.0 | 1659.0 | 1.0 | False | None | None | False | None | False | 1659.0 | 0 |
3885704 | 149276 | None | code305 | GSM modem with connecting cable for remote communicating capabilities | No | 14415.0 | 14415.0 | 1.0 | False | None | None | False | None | False | 14415.0 | 0 |
3885705 | 149276 | None | code306 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2) Armouring wires dia and Resistivity as per
IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia) | Km | 889666.0 | 889666.0 | 0.15 | False | None | None | False | None | False | 133449.9 | 0 |
3885706 | 149276 | None | code307 | Heat Shrinkable Indoor Type Cable Termination Kit
for XLPE Cable 3x95 Sqmm | Set | 3744.0 | 3744.0 | 6.0 | False | None | None | False | None | False | 22464.0 | 0 |
3885707 | 149276 | None | code308 | Heat Shrinkable Outdoor Type Cable Termination
Kit for XLPE Cable 3x95 Sqmm | Set | 4067.0 | 4067.0 | 2.0 | False | None | None | False | None | False | 8134.0 | 0 |
3885708 | 149276 | None | code309 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff HT Cable 3x95 to 150 Sqmm | Km | 61322.0 | 61322.0 | 0.15 | False | None | None | False | None | False | 9198.3 | 0 |
3885709 | 149276 | None | code310 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm) | Km | 178973.0 | 178973.0 | 0.15 | False | None | None | False | None | False | 26845.95 | 0 |
3885710 | 149276 | None | code311 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm) | Km | 139549.0 | 139549.0 | 0.1 | False | None | None | False | None | False | 13954.9 | 0 |
3885711 | 149276 | None | code312 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 10 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm) | Km | 118004.0 | 118004.0 | 0.15 | False | None | None | False | None | False | 17700.6 | 0 |
3885712 | 149276 | None | code313 | Compression type Aluminium Tubular in Line Connector for Aluminum Conductor
16 sqmm | No | 3.0 | 3.0 | 48.0 | False | None | None | False | None | False | 144.0 | 0 |
3885713 | 149276 | None | code314 | Heavy Duty Copper Terminal Long Barrel
25 Sqmm Copper Terminal, Apprx Wt: 11 Gm | No | 27.0 | 27.0 | 32.0 | False | None | None | False | None | False | 864.0 | 0 |
3885714 | 149276 | None | code315 | Heavy Duty Copper Terminal Long Barrel
50 Sqmm Copper Terminal, Apprx Wt: 26 Gm | No | 58.0 | 58.0 | 24.0 | False | None | None | False | None | False | 1392.0 | 0 |
3885715 | 149276 | None | code316 | Brass Cable Gland 25 | No | 79.0 | 79.0 | 4.0 | False | None | None | False | None | False | 316.0 | 0 |
3885716 | 149276 | None | code317 | Brass Cable Gland 32 | No | 95.0 | 95.0 | 4.0 | False | None | None | False | None | False | 380.0 | 0 |
3885717 | 149276 | None | code318 | Route & Joint indicating slab with MS Anchor rod | No | 133.0 | 133.0 | 12.0 | False | None | None | False | None | False | 1596.0 | 0 |
3885718 | 149276 | None | code319 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 Sqmm | Km | 20886.0 | 20886.0 | 0.25 | False | None | None | False | None | False | 5221.5 | 0 |
3885719 | 149276 | None | code320 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 35 to 95 Sqmm | Km | 31139.0 | 31139.0 | 0.15 | False | None | None | False | None | False | 4670.85 | 0 |
3885720 | 149276 | None | code321 | Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14 SWG | Sq CM | 0.5 | 0.5 | 250000.0 | False | None | None | False | None | False | 125000.0 | 0 |
3885721 | 149276 | None | code322 | Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound. | Each | 562.0 | 562.0 | 4.0 | False | None | None | False | None | False | 2248.0 | 0 |
3885722 | 149276 | None | code323 | Supplying and fixing Electronic Trivector Meter (ETV)suitable for operation LT operation and - CT operated meter in polycarbonate body in class0.5 accuracy as per IS 14697 and completely wired. | Each | 4390.0 | 4390.0 | 1.0 | False | None | None | False | None | False | 4390.0 | 0 |
3885723 | 149276 | None | code324 | Supplying and fixing of Shunt trip suitable for MCCB.CBCT | Each | 1703.0 | 1703.0 | 1.0 | False | None | None | False | None | False | 1703.0 | 0 |
3885724 | 149276 | None | code325 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 9255.0 | 9255.0 | 1.0 | False | None | None | False | None | False | 9255.0 | 0 |
3885725 | 149276 | None | code326 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C | Each | 515.0 | 515.0 | 3.0 | False | None | None | False | None | False | 1545.0 | 0 |
3885726 | 149276 | None | code327 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP | Each | 415.0 | 415.0 | 4.0 | False | None | None | False | None | False | 1660.0 | 0 |
3885727 | 149276 | None | code328 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy | Each | 9315.0 | 9315.0 | 1.0 | False | None | None | False | None | False | 9315.0 | 0 |
3885728 | 149276 | None | code329 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR Pole 100 A 25 kA | Each | 8487.0 | 8487.0 | 1.0 | False | None | None | False | None | False | 8487.0 | 0 |
3885729 | 149276 | None | code330 | Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 100 A 4 x 30 x 6 mm Aluminium Strips | m | 2465.0 | 2465.0 | 6.0 | False | None | None | False | None | False | 14790.0 | 0 |
3885730 | 149276 | None | code331 | Rotary handle for MCCB | Each | 3748.0 | 3748.0 | 1.0 | False | None | None | False | None | False | 3748.0 | 0 |
3885731 | 149276 | None | code332 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A TPN | Each | 3088.0 | 3088.0 | 6.0 | False | None | None | False | None | False | 18528.0 | 0 |
3885732 | 149276 | None | code333 | Supplying of on load change over switches 4 poles, AC-23ADuty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution) 100 A | Each | 8534.0 | 8534.0 | 1.0 | False | None | None | False | None | False | 8534.0 | 0 |
3885733 | 149276 | None | code334 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A DP | Each | 1060.0 | 1060.0 | 4.0 | False | None | None | False | None | False | 4240.0 | 0 |
3885734 | 149276 | None | code335 | Supplying and fixing angle iron frame work fabricated out of M.S.angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mm | m | 305.0 | 305.0 | 25.0 | False | None | None | False | None | False | 7625.0 | 0 |
3885735 | 149276 | None | code336 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. II - Double Door 12 Way SP & N | Each | 2329.0 | 2329.0 | 1.0 | False | None | None | False | None | False | 2329.0 | 0 |
3885736 | 149276 | None | code337 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 32-40A 2 pole | Each | 4559.0 | 4559.0 | 2.0 | False | None | None | False | None | False | 9118.0 | 0 |
3885737 | 149276 | None | code338 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP | Each | 415.0 | 415.0 | 10.0 | False | None | None | False | None | False | 4150.0 | 0 |
3885738 | 149276 | None | code339 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. III - Double Door 4 Way TP & N | Each | 4038.0 | 4038.0 | 2.0 | False | None | None | False | None | False | 8076.0 | 0 |
3885739 | 149276 | None | code340 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 63 A 4 pole | Each | 5545.0 | 5545.0 | 2.0 | False | None | None | False | None | False | 11090.0 | 0 |
3885740 | 149276 | None | code341 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A SP | Each | 415.0 | 415.0 | 24.0 | False | None | None | False | None | False | 9960.0 | 0 |
3885741 | 149276 | None | code342 | Fixing Danger Board | Each | 80.0 | 80.0 | 6.0 | False | None | None | False | None | False | 480.0 | 0 |
3885742 | 149276 | None | code343 | Supply and installation in position, testing and commissioning 6kg Fire Ex tinguisher Mono Ammonium Phos phate Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight 9.5 Kg, empty weight 3.5 Kg, Can Height 435MM, Diameter 160MM, Discharge Time less than 9 Sees, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 4 meters, applicable on Class A,8,C and electrically started Fire, A Rating 3A, 8 Rating 218, Can construction : Deep drawn & Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy PoIyster power coating, Sheet metal thickness: 1.60MM, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost cost of supporting materials like MS stand & accessaries if it is fixing n floor / MS brackets &
accessories if it is fixing on wall,,, labour, usage charges of machinery complete as per specificed.with regards to general guidelines of fire safe | Each | 2850.0 | 2850.0 | 4.0 | False | None | None | False | None | False | 11400.0 | 0 |
3885743 | 149276 | None | code344 | Supplying of four bucket stand alongwith buckets. Complete | Each | 1850.0 | 1850.0 | 2.0 | False | None | None | False | None | False | 3700.0 | 0 |
3885744 | 149276 | None | code345 | Supplying of Hand gloves. complete | Each | 975.0 | 975.0 | 1.0 | False | None | None | False | None | False | 975.0 | 0 |
3885745 | 149276 | None | code346 | Supplying of first aid box. Complete | Each | 600.0 | 600.0 | 1.0 | False | None | None | False | None | False | 600.0 | 0 |
3885746 | 149276 | None | code347 | Supplying of SAFETY MASK. Complete | Each | 150.0 | 150.0 | 1.0 | False | None | None | False | None | False | 150.0 | 0 |
3885747 | 149276 | None | code348 | Supplying of FIRST AID CHART with lamination. Complete | Each | 400.0 | 400.0 | 2.0 | False | None | None | False | None | False | 800.0 | 0 |
3885748 | 149276 | None | code349 | Supplying and installation of RUBBER MAT 1mtr x 1mtr -1Omm thick. complete including cost of materials, labour, usage charges of machinery complete as per specifications. | Each | 1900.0 | 1900.0 | 4.0 | False | None | None | False | None | False | 7600.0 | 0 |
3885749 | 149276 | None | code350 | Removing and refixing Drain Cover slabs (B S Slab and RCC slab) and pointing in CM (1:3) as directed by the Engineer in Charge of the work (excluding GST and Area Leading Charges | Sqm | 235.0 | 235.0 | 948.6 | False | None | None | False | None | False | 222921.0 | 0 |
3885750 | 149276 | None | code351 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead Dismantling Stone Masonry Rubble stone masonry in cement mortar. | Cum | 671.0 | 671.0 | 142.2 | False | None | None | False | None | False | 95416.2 | 0 |
3885751 | 149276 | None | code352 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. | Cum | 266.2 | 266.2 | 306.9 | False | None | None | False | None | False | 81696.78 | 0 |
3885752 | 149276 | None | code353 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6230.4 | 6230.4 | 7.199 | False | None | None | False | None | False | 44852.6496 | 0 |
3885753 | 149276 | None | code354 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with Centering. | Cum | 9389.65 | 9389.65 | 123.3 | False | None | None | False | None | False | 1157743.845 | 0 |
3885754 | 149276 | None | code355 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.h. All other type of structures | MT | 86912.1 | 86912.1 | 8.45 | False | None | None | False | None | False | 734407.245 | 0 |
3885755 | 149276 | None | code356 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications | Sqm | 1354.1 | 1354.1 | 38.0 | False | None | None | False | None | False | 51455.8 | 0 |
3885756 | 149276 | None | code357 | Providing and fixing RCC precast cover slab of 10 cm thick for drain in cement concrete M20 using graded granite jelly 20mm and down size with steel reinforcement, including formwork, lift charges, curing and concrete finished surfaces on both sides etc., complete as per drawing and directions of engineer-in-charge.Data rate | Sqm | 2072.0 | 2072.0 | 150.66 | False | None | None | False | None | False | 312167.52 | 0 |
3885757 | 149276 | None | code358 | Providing and fixing RCC precast cover slab of 23 cm thick for drain in cement concrete M20 using graded granite jelly 20mm and down size with steel reinforcement, including formwork, lift charges, curing and concrete finished surfaces on both sides etc., complete as per drawing and directions of engineer-in-charge.Data rate - Data rate | Sqm | 5037.0 | 5037.0 | 60.0 | False | None | None | False | None | False | 302220.0 | 0 |
3885758 | 149276 | None | code359 | Removing & Resetting of Kerb Stones - DATA RATE | m | 118.0 | 118.0 | 930.0 | False | None | None | False | None | False | 109740.0 | 0 |
3885759 | 149276 | None | code360 | Providing and fixing pre cast solid cement concrete kerb stones made out of M20 with top and bottom width 114 and 165 mm respectively, 400mm high and 450mm in length finished with CM 1:3 plastering and finishing cutting including formwork, curing, including cost of materials, labour charges of machinery, loading and unloading, lead and lift, transportation ete.,complete as directed by the Engineer in Charge of the work (excluding GST and Area Leading Charges) | Nos | 325.0 | 325.0 | 889.0 | False | None | None | False | None | False | 288925.0 | 0 |
3885760 | 149276 | None | code361 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces | Sqm | 119.9 | 119.9 | 800.0 | False | None | None | False | None | False | 95920.0 | 0 |
3885761 | 149276 | None | code362 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. | Cum | 71.5 | 71.5 | 257.4 | False | None | None | False | None | False | 18404.1 | 0 |
3885762 | 149276 | None | code363 | Wet Mix Macadam (Plant mix method)
Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. | Cum | 2633.4 | 2633.4 | 223.08 | False | None | None | False | None | False | 587458.872 | 0 |
3885763 | 149276 | None | code364 | Prime Coat over WMM/WBM
Providing and applying primer coat with SS1 grade Bitumen Emulsion on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.90 kg per m2 using mechanical means. | Sqm | 48.4 | 48.4 | 858.0 | False | None | None | False | None | False | 41527.2 | 0 |
3885764 | 149276 | None | code365 | Tack coat on Bituminous surface
Providing and applying tack coat with RS1 Bituminous Emulsion using emulsion pressure distributor at the rate of 0.20 kg/m2 on the prepared bituminous surface cleaned with mechanical broom | Sqm | 13.2 | 13.2 | 4894.5 | False | None | None | False | None | False | 64607.4 | 0 |
3885765 | 149276 | None | code366 | Providing and laying Dense Graded Bituminous Macadam with 40/60 TPH capacity HMP using crushed aggregates of specified grading, premixed with bituminous binder VG-30, @ 4.5 per cent by weight of total mix and filler, transporting the hot mix to work site, laying with mechanical paver finisher to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 505 complete in all respects. Dense Graded Bituminous Macadam Grading - II for traffic lesser than 20 MSA | Cum | 10877.9 | 10877.9 | 62.9 | False | None | None | False | None | False | 684219.91 | 0 |
3885766 | 149276 | None | code367 | Bituminous Concrete Grading II Using waste plastic Providing and laying Bituminous Concrete with not less than 40/60 TPH capacity HMP using crushed aggregates of specified grading, premixed with bituminous binder VG-30 @ 4.78% Bitumen and waste plastic 8% of Bitumen of mix and filler, transporting the hot mix to work site, laying with mechanical paver finisher to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects | Cum | 11740.3 | 11740.3 | 195.78 | False | None | None | False | None | False | 2298515.934 | 0 |
3885767 | 149276 | None | code368 | Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface Providing and laying of hot applied thermoplastic compound 2.5 mm thick including reflectorising glass beads @ 250 g/ m2 area, thickness of 2.5 mm is exclusive of surface applied glass beads as per IRC:35:2015.The finished surface to be level, uniform and free from streaks and holes. | Sqm | 525.8 | 525.8 | 143.0 | False | None | None | False | None | False | 75189.4 | 0 |