1725097832000 | 0 | None | None | Buildings | Construction of a New Deputy Director of Horticulture office and other works in the premises of Horticulure officer Department located in Kohinoor Road at Madikeri Taluk | 1352861.41 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3894018 | 149813 | None | 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth up to 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift up to 1.5 m including cost of labor, tools, usage of machinery & other appurtenances required to complete the work In all kinds of soils Depth up to 3 m (V0l-1 sr it.no.1.14.1) | Cum | 114.24 | 114.24 | 1.296 | False | None | None | False | None | False | 148.05504 | 0 | 3894019 | 149813 | None | 1:4:8 | Providing and laying in position plain cement concrete for leveling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labor, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)(V0l-1 sr it.no.2.1.2 )Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6343.68 | 6343.68 | 1.296 | False | None | None | False | None | False | 8221.40928 | 0 | 3894020 | 149813 | None | 2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings( P.no. 18 I.No.2.11a) | t | 101193.76 | 101193.76 | 0.3024 | False | None | None | False | None | False | 30600.993024 | 0 | 3894021 | 149813 | None | 2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labor, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) FOR ROOF SLAB(common sr it.no.2.5.1 of 2023-24)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 12697.78 | 12697.78 | 2.16 | False | None | None | False | None | False | 27427.2048 | 0 | 3894022 | 149813 | None | 6.34 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications (CSR Vol 2 It no:6.34 Pg No 17) | Sqm | 1248.84 | 1248.84 | 35.1 | False | None | None | False | None | False | 43834.284 | 0 | 3894023 | 149813 | None | 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(It no:8.2.1, P.No 41 of Vol-2 SR 2023-24) | Sqm | 333.7 | 333.7 | 66.0 | False | None | None | False | None | False | 22024.2 | 0 | 3894024 | 149813 | None | 8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Vol-2 sr item num:8.25 P No 45) | Sqm | 154.97 | 154.97 | 66.0 | False | None | None | False | None | False | 10228.02 | 0 | 3894025 | 149813 | None | 8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Vol-2 sr item num:8.25 P No 45) | Sqm | 153.44 | 153.44 | 219.62 | False | None | None | False | None | False | 33698.4928 | 0 | 3894026 | 149813 | None | 9.12.3 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 800x800 mm ( P.no.60 I.no.9.12.3 ) | Sqm | 1421.92 | 1421.92 | 11.95 | False | None | None | False | None | False | 16991.944 | 0 | 3894027 | 149813 | None | 11.16.2 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(It no:11.16.2 Pg.No:-81 of Vol-2 SR 2023-24)for above roof column | Kg | 166.29 | 166.29 | 1035.18 | False | None | None | False | None | False | 172140.0822 | 0 | 3894028 | 149813 | None | 11.16.2 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(It no:11.16.2 Pg.No:-81 of Vol-2 SR 2023-24)for fortico | Kg | 164.64 | 164.64 | 883.58 | False | None | None | False | None | False | 145472.6112 | 0 | 3894029 | 149813 | None | 7.39.6 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete Gutter (600 mm over all girth.(It no:7.39.6, P.No 26 of Vol-2 SR 2022) | Sqm | 1202.88 | 1202.88 | 10.0 | False | None | None | False | None | False | 12028.8 | 0 | 3894030 | 149813 | None | 20.100 | Supplying and fixing new Mangalore tiles on existing Reepers ( P.no.207 I.no.20.100 ) | Sqm | 533.12 | 533.12 | 51.4 | False | None | None | False | None | False | 27402.368 | 0 | 3894031 | 149813 | None | 20.98 | Providing Mangalore Ridge tiles set in C.M. 1:2 and pointed with C.M. 1:2. ( P.no.207 I.no.20.98) | m | 278.88 | 278.88 | 5.0 | False | None | None | False | None | False | 1394.4 | 0 | 3894032 | 149813 | None | 11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Vol 2 It No 11.28 Pg no 83) | Kg | 632.8 | 632.8 | 150.0 | False | None | None | False | None | False | 94920.0 | 0 | 3894033 | 149813 | None | 7.38 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.(It no:7.38, P.No 26 of Vol-2 SR 2022)
| Sqm | 642.52 | 642.52 | 94.35 | False | None | None | False | None | False | 60621.762 | 0 | 3894034 | 149813 | None | 7.39.1 | Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500 - 600mm).(It no:7.39.1, P.No 26 of Vol-2 SR 203-24) | m | 510.17 | 510.17 | 8.5 | False | None | None | False | None | False | 4336.445 | 0 | 3894035 | 149813 | None | 14.3.1 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid.( P.no.122 I.no.14.3.1) | No | 6694.24 | 6694.24 | 1.0 | False | None | None | False | None | False | 6694.24 | 0 | 3894036 | 149813 | None | 14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. ( P.N 124 In:14.7.1) | No | 3451.84 | 3451.84 | 1.0 | False | None | None | False | None | False | 3451.84 | 0 | 3894037 | 149813 | None | 10.1.1 (M010B) | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:.( BWSSB 2023-24 P.no.113 I.no. 10.1.1 (M010B) PVC pipes 25 mm dia., 10 kg/sqcm & class 5 | m | 53.76 | 53.76 | 30.0 | False | None | None | False | None | False | 1612.8 | 0 | 3894038 | 149813 | None | 10.1.7 (M010G) | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:.( BWSSB 2023-24 pg 113 it 10.1.7 (M010G) PVC pipes 110mm dia., 6 kg/sqcm & class 3 | m | 460.32 | 460.32 | 30.0 | False | None | None | False | None | False | 13809.6 | 0 | 3894039 | 149813 | None | T130C WSR | Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.( P.no.187 I.no. T130C WSR) | No | 4327.68 | 4327.68 | 2.0 | False | None | None | False | None | False | 8655.36 | 0 | 3894040 | 149813 | None | 13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.(2023-24 sr Vol 2 it no 13.34 pg 123) | Ltr | 10.18 | 10.18 | 1000.0 | False | None | None | False | None | False | 10180.0 | 0 | 3894041 | 149813 | None | 14.1.1 | Providing and fixing water closet squatting pan (Indian type W.C. pan )with 100 mm sand cast Iron P or S trap, 10 litre low level whiteP.V.C. flushing cistern, including flush pipe, with manually controlleddevice (handle lever) conforming to IS : 7231, with all fittings andfixtures complete, including cutting and making good the walls andfloors wherever required:14.1.1 White Vitreous china Orissa pattern W.C. pan of size 580x440 mm withintegral type foot rests(Vol 2, P No 123 IN0 14.1.1) | No | 5470.08 | 5470.08 | 1.0 | False | None | None | False | None | False | 5470.08 | 0 | 3894042 | 149813 | None | 12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with
19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.(Vol-2 sr item num:12.54 P No 104) | m | 356.16 | 356.16 | 5.4 | False | None | None | False | None | False | 1923.264 | 0 | 3894043 | 149813 | None | 12.53 | Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm
thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges.(Vol-2 sr item num:12.53 P No 104) | Sqm | 1778.56 | 1778.56 | 1.62 | False | None | None | False | None | False | 2881.2672 | 0 | 3894044 | 149813 | None | 9.6.1 | Providing and laying Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand) Light shade pigment using white cement(It no:9.6.1, of Vol-2 SR 203-24) | Sqm | 1421.28 | 1421.28 | 8.235 | False | None | None | False | None | False | 11704.2408 | 0 | 3894045 | 149813 | None | 7.15.2 | KSRB 7.15 : Providing, fabricating, assembling and fixing in position aluminium partitions using aluminium sections of mat finish or glassy finish in combination of plain grove, single grove and double grove as per requirements for the frames of overall size 63.5mm x 38.1mm. with thickness of 2mm. having section weight, plain sections 1.054kg/m, single grove thickness 1.95mm. section weight 1.094kg/m, double grove thickness 1.9mm section weight 1.094kg/m and bottom member 114.3 mm. x 44.45mm. thickness 3.18mm. weight 2.646 kg/m; aluminium louvres section of size 36.5mmx34.93mm 1.45mm. thick section weight 0.429kg/m; bottom portions provided with 12mm. thick prelaminated sheet both sides of approved colour lamination exterior grade upto 0.9m height, spacing of vertical member not exceeding 0.6 m. c to c; sections are cut to the required lengths, joints mitered and corners grinded subdividing frames tennoned and rivetted to the frames; the assembled frame stiffened with corner angles, stripped and fixed with screws, rawl plugs and teak wood gutties to R.C.C.columns on sides, R.C.C. lintels or beams at top and floor at bottom, including cutting chistelling and making good with cement mortar to match the surface; providing and fixing 5.5mm. thick plain glass for middle portion viz., 0.9m. to 2.13 m. and top panel with louvres sections; the glass and panels fitted withglazing clips of 19mmx17.3mm. of thickness 0.9mm. weight 0.124kg/ m, aluminium sections treated for removal of any rust and prevention of further rust formation, coated with greasy materials for non-adherence of mortars or any other sticky materials; vertical members embedded in the flooring by making suitable sized holes and fixing with cement mortar, with necessary opening for fixing of door of standard size (excluding cost of door ) all the frame throughly cleaned, free from rust, scale or dirt including cost of materials, fixtures, labour and HOM of machinery complete as per specifications. using aluminium section powdered coated to a minimum of 60-70 microns with exterior durable pure polyester grade powder of approved quality.(2018-19 Sr it no 7.15.2 ) | Sqm | 3843.84 | 3843.84 | 94.56 | False | None | None | False | None | False | 363473.5104 | 0 | 3894046 | 149813 | None | 7.32.3 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 g/m2
(both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum moisture resistant board ( P.no.25 I.no.7.32.3 ) | Sqm | 1283.52 | 1283.52 | 27.6 | False | None | None | False | None | False | 35425.152 | 0 | 3894047 | 149813 | None | Executive Table | Executive Table with Side Return Main table with grommet, PVC writing pad;fixed Side-retun; other same as sample(white aluminium strip); MDF part of top:oak and red CSSlnut is mat black; Wenge is a little shinny paint.Movable pedestal and KB tray. No need CPU trolley as Side return has that cabinet for CPU ( 1600Wx1850Dx750H) (other Sr 2019-20 it code Executive Table) | No | 40161.0 | 40161.0 | 1.0 | False | None | None | False | None | False | 40161.0 | 0 | 3894048 | 149813 | None | CSS-799A | Heigh Back Revolving Chair (other Sr 2019-20 it code CSS-799A) | No | 12250.0 | 12250.0 | 1.0 | False | None | None | False | None | False | 12250.0 | 0 | 3894049 | 149813 | None | CSS-623D | Visitor chair with Plywood inner structure, PU upholestry In seat & Back, PP chrome cladded Arms with PU upholestry, (other Sr 2019-20 it code CSS-623D) | m | 6760.0 | 6760.0 | 4.0 | False | None | None | False | None | False | 27040.0 | 0 | 3894050 | 149813 | None | CSS-Almira(6Hx3W) | Providing and fixing metal office cupboard (Almira (Godrej Type) 6.50x 3.00' the wider and deeper options in our cupboard range. Adjustable shelves, lockable security Multi bend construction, inter locking design & full length overlapping door & sides Lock has steel. looms with designer aesthetics & comfortable angular handle for grip Almira 20gauge body doors and selves 18 gauge) (other Sr 2019-20 it code CSS-Almira)(6Hx3W) | No | 19184.0 | 19184.0 | 1.0 | False | None | None | False | None | False | 19184.0 | 0 | 3894051 | 149813 | None | 12.66.2 | Providing and fixing chromium plated brass curtain rod with ISI mark hav ing wall thickness of 1.25mm with two chromium plated brass brackets fixed with C.P. brass screws and PVC sleeves etc., wherever necessary complete 20mm dia.(Vol-2 sr item num:12.66.2 P No 106) | m | 731.36 | 731.36 | 4.8 | False | None | None | False | None | False | 3510.528 | 0 | 3894052 | 149813 | None | 12.24 | Providing & fixing 100% Polyester Curtains with specification of regular wash as per direction of Engineer in charge.(Vol-2 sr item num:12.24 P No 219) | Sqm | 1344.0 | 1344.0 | 5.795 | False | None | None | False | None | False | 7788.48 | 0 | 3894053 | 149813 | None | 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.a).2.5 sqmm(It.no.2.3.3 & P.no.5) | Mtr | 42.0 | 42.0 | 170.0 | False | None | None | False | None | False | 7140.0 | 0 | 3894054 | 149813 | None | 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.a).4.0sqmm(It.no.2.3.4 & P.no.5) | Mtr | 63.0 | 63.0 | 170.0 | False | None | None | False | None | False | 10710.0 | 0 | 3894055 | 149813 | None | 3.4.3 | Supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C walla).4-5 Way(It.no.3.4.3 & P.no.8) | Each | 177.0 | 177.0 | 10.0 | False | None | None | False | None | False | 1770.0 | 0 | 3894056 | 149813 | None | 3.4.4 | Supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C walla).6 Way(It.no.3.4.4 & P.no.8) | Each | 220.0 | 220.0 | 10.0 | False | None | None | False | None | False | 2200.0 | 0 | 3894057 | 149813 | None | 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.a). 6Amps one way Switch(It.no.3.6.1 & P.no.9) | Each | 102.0 | 102.0 | 30.0 | False | None | None | False | None | False | 3060.0 | 0 | 3894058 | 149813 | None | 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.b). 6Amps 3way socket (It.no.3.6.3 & P.no.9) | Each | 171.0 | 171.0 | 20.0 | False | None | None | False | None | False | 3420.0 | 0 | 3894059 | 149813 | None | 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.c). Stepped Fan Regulator Two Module(It.no.3.6.4 & P.no.9) | Each | 357.0 | 357.0 | 10.0 | False | None | None | False | None | False | 3570.0 | 0 | 3894060 | 149813 | None | 11.3.2 | Supplyingof.feet-C Batten with integrated LED tube.W with high quality diffuser with Life of 25000 burning hours& 70% lumen maintenance with CRI greaterthan 80.Power Input:220-240V@50/60Hz&Powerfactor greaterthan0.9along with CE approved. 2years Warranty against any manufacturing defect working understandard electrical condition.a)LED light fitting 1 x 4' - 20/22 W(It.no.11.3.2 & P.no.43) | Each | 690.0 | 690.0 | 5.0 | False | None | None | False | None | False | 3450.0 | 0 | 3894061 | 149813 | None | 11.11.5 | Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI greaterthan 70%. efficacy greaterthgan80 lumen per watt, life greaterthan25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greaterthan 0.95, power loss should lesserthan 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.a)12W, 6500K(It.no.11.11.5 & P.no.47) | Each | 269.0 | 269.0 | 5.0 | False | None | None | False | None | False | 1345.0 | 0 | 3894062 | 149813 | None | 6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment, Rated voltage 220 V/ 50 Hz, Rated power input 48 W +/-10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value greaterthan or equal to 4.2 CMM / Watt, Three Blades of blade leaf 1.05mm thick luminium Alloy sheet,Class B motorinsulation,Bearing Two ball bearings, Top 6202, Bottom 6201 , as per IS specification, Motor wdg. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245Volts, Insulation resistance Shall not be less than Two Mega Ohms (2 M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, watt& current , Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.a)48" Sweep 5 Star (1200 mm)(It.no.6.4.1 & P.no.23) | Each | 2949.0 | 2949.0 | 10.0 | False | None | None | False | None | False | 29490.0 | 0 |
|