1725097234000 | 0 | None | None | Buildings | Construction Of Two-Bedroom Residential House for the Medical Officer In the Premises of District Government Ayurvedic Hospital In madikeri | 2966819.31 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3893846 | 149803 | None | 1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth up to 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift up to 1.5 m including cost of labor, tools, usage of machinery & other appurtenances required to complete the work In all kinds of soils Depth up to 3 m (V0l-1 sr it.no.1.14.1 ) | Cum | 114.24 | 114.24 | 48.57 | False | None | None | False | None | False | 5548.6368 | 0 | 3893847 | 149803 | None | 2.0 | Providing rubble stone / boulder filling behind abutment / belowapron including cost of all materials, labour, hand packing, finishing topsurface etc., complete with all lead and lifts.(MI sr it.no.2.0 pg no 19 ) | Cum | 1386.56 | 1386.56 | 3.375 | False | None | None | False | None | False | 4679.64 | 0 | 3893848 | 149803 | None | 2.1.2 | Providing and laying in position plain cement concrete for leveling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labor, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)(V0l-1 sr it.no.2.1.2 )Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6343.68 | 6343.68 | 8.175 | False | None | None | False | None | False | 51859.584 | 0 | 3893849 | 149803 | None | 2.2.3 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labor, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)(Vol-1 sr it.no.2.2.3 )M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7664.03 | 7664.03 | 18.5625 | False | None | None | False | None | False | 142263.556875 | 0 | 3893850 | 149803 | None | 2.4.3 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labor, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)(common sr it.no.2.4.3 )M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for plinth | Cum | 10644.48 | 10644.48 | 2.934 | False | None | None | False | None | False | 31230.90432 | 0 | 3893851 | 149803 | None | 2.4.3 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labor, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)(common sr it.no.2.4.3 )M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for columns | Cum | 12063.74 | 12063.74 | 2.52 | False | None | None | False | None | False | 30400.6248 | 0 | 3893852 | 149803 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labor, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) FOR ROOF SLAB(common sr it.no.2.5.2 of 2023-24)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Beam & lintel | Cum | 12262.66 | 12262.66 | 4.152 | False | None | None | False | None | False | 50914.56432 | 0 | 3893853 | 149803 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labor, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) FOR ROOF SLAB(common sr it.no.2.5.2 of 2023-24)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for staircase,landing & waist slab | Cum | 8430.58 | 8430.58 | 1.485 | False | None | None | False | None | False | 12519.4113 | 0 | 3893854 | 149803 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labor, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) FOR ROOF SLAB(common sr it.no.2.5.2 of 2023-24)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for slab | Cum | 11496.24 | 11496.24 | 10.644 | False | None | None | False | None | False | 122365.97856 | 0 | 3893855 | 149803 | None | 2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings( P.no. 18 I.No.2.11a) | t | 100191.84 | 100191.84 | 3.3426 | False | None | None | False | None | False | 334901.244384 | 0 | 3893856 | 149803 | None | 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications (CSR Vol 2 It no:6.32 Pg No 17) | Sqm | 1467.2 | 1467.2 | 70.02 | False | None | None | False | None | False | 102733.344 | 0 | 3893857 | 149803 | None | 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(It no:8.2.1, P.No 41 of Vol-2 SR 2023-24) | Sqm | 330.4 | 330.4 | 293.89 | False | None | None | False | None | False | 97101.256 | 0 | 3893858 | 149803 | None | 8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Vol-2 sr item num:8.25 P No 45) | Sqm | 153.44 | 153.44 | 215.62 | False | None | None | False | None | False | 33084.7328 | 0 | 3893859 | 149803 | None | 8.36.2 | Finishing with Epoxy paint (two coats) at all locations preparedand applied as per manufacturer's specifications including appropriatepriming coat, preparation of surface, etc. complete. On concrete workincluding preparing the surface after thorougly cleaning oil, grease,dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Vol-2 sr item num:8.36.2 P No 47) | Sqm | 192.64 | 192.64 | 84.27 | False | None | None | False | None | False | 16233.7728 | 0 | 3893860 | 149803 | None | 11.34B | Providing and fixing M.S. grills of required pattern in frames of win dows etc. with M.S. flats, squareor round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc( SR Vol-2/P.no. 85 I.No.11.34B) | Kg | 204.96 | 204.96 | 168.75 | False | None | None | False | None | False | 34587.0 | 0 | 3893861 | 149803 | None | 8.40 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. ( P.no.48 I.no.8.40) | Sqm | 128.8 | 128.8 | 5.625 | False | None | None | False | None | False | 724.5 | 0 | 3893862 | 149803 | None | 12.84 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size- 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). ( P.no.110, I.no12.84) | Sqm | 5625.76 | 5625.76 | 11.52 | False | None | None | False | None | False | 64808.7552 | 0 | 3893863 | 149803 | None | 9.96 | Providing and fixing 65mmx125mm GRP Doorframe fabricated using E-Giass Chopped Strand Mat (CSM) U.V- stabilized lsopthalic Gelcoat and lsopthalic resin. The thickness of the GRP skin shall not be less than 2.0mm. The doorframe consists of four segments, which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screws. The GRP frame shall be provided with wooden reinforcement on 6 locations for high screw holding capacity for fixing metalling hold fast and shall be consolidated by filling with medium density foam/Plaster of Paris with fibre reinforcement Six Numbers of 260mmx25mmx5mm sizeS shaped M.S. flat hold fast shall be provided with the frame.( SR 18-19 Item.no:-9.96) | m | 616.0 | 616.0 | 25.2 | False | None | None | False | None | False | 15523.2 | 0 | 3893864 | 149803 | None | 9.93 | Providing and fixing factory made single leaf rigid GRP Sandwich composite door shutter of 32mm thick, laminated with two GRP skins with wood grain finish, fabricated using U.V-stabilized lsopthalic Gelcoat and on layer of 45 gsm E-Giass Chopped strand Mat (CSM), impregnated with orthopthalic polyster resin. The thickness of the skins shall not be less than 1.5mm. Expanded Polystyrene (EPS) structural foam panel of 29mm thickness and a density of 20 Kg/m3 shall be used as core material. Wooden reinforcements made of Seasoned Salwood block of cross section not less than 28mmx32mm and also necessary salwood reinforcements for fixing the metal fittings such as tower bolts, aldrops, handles, etc, shall be provided. A structural adhesive compatible with EPS foam shall be used for bonding the core material, the Salwood reinforcement and the skins. The material and process for manufacturing the door shutters shall confirm to Standards and specifications and the door shutters tested in confiramation to IS 4020-1994. The finish of shutter will be plain colour White/Ivory/Beige/Light Grey or any other colour using high quality pigments. Exclusing cost of fixtures and inclusive of supply of shutters to respective work spot.(SR 2018-19 Item.no:-9.93) | Sqm | 3360.0 | 3360.0 | 8.82 | False | None | None | False | None | False | 29635.2 | 0 | 3893865 | 149803 | None | 9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm ( P.no.60 I.no.9.12.2 ) | Sqm | 1282.4 | 1282.4 | 69.48 | False | None | None | False | None | False | 89101.152 | 0 | 3893866 | 149803 | None | 14.3.1 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid.( P.no.122 I.no.14.3.1) | No | 6694.24 | 6694.24 | 1.0 | False | None | None | False | None | False | 6694.24 | 0 | 3893867 | 149803 | None | 14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. ( P.N 124 In:14.7.1) | No | 3451.84 | 3451.84 | 2.0 | False | None | None | False | None | False | 6903.68 | 0 | 3893868 | 149803 | None | 13.17.1 | Providing and fixing PTMT bib cock of approved quality and colour. 15mm nominal bore, 86 mm long, weighing not less than 88 ( P.N A 120 In:13.17.1) | Each | 302.4 | 302.4 | 6.0 | False | None | None | False | None | False | 1814.4 | 0 | 3893869 | 149803 | None | 10.1.1 (M010B | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:.( BWSSB 2023-24 P.no.113 I.no. 10.1.1 (M010B) PVC pipes 25 mm dia., 10 kg/sqcm & class 5 | m | 53.76 | 53.76 | 150.0 | False | None | None | False | None | False | 8064.0 | 0 | 3893870 | 149803 | None | 10.1.7 (M010G) | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:.( BWSSB 2023-24 pg 113 it 10.1.7 (M010G) PVC pipes 110mm dia., 6 kg/sqcm & class 3 | m | 460.32 | 460.32 | 30.0 | False | None | None | False | None | False | 13809.6 | 0 | 3893871 | 149803 | None | np2 | RCC NP 2 1200mm dia (2023-24 CSR It No 41 pg no A-27) | m | 4840.64 | 4840.64 | 6.0 | False | None | None | False | None | False | 29043.84 | 0 | 3893872 | 149803 | None | T130C WSR | Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.( P.no.187 I.no. T130C WSR) | Each | 4327.68 | 4327.68 | 2.0 | False | None | None | False | None | False | 8655.36 | 0 | 3893873 | 149803 | None | 14.10.1.1 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board 510x1040 mm bowl depth 250 mm ( P.N 133 In:14.10.1.1) | No | 6292.16 | 6292.16 | 1.0 | False | None | None | False | None | False | 6292.16 | 0 | 3893874 | 149803 | None | 9.36 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. ( P.N 64 In:9.36) | Sqm | 1848.0 | 1848.0 | 3.0 | False | None | None | False | None | False | 5544.0 | 0 | 3893875 | 149803 | None | 39.3 | Manufacturing, supplying and fixing wooden ward robe of 0.60m deep using 19mm thick vinyl bonded water proof block board, shutters allround ward robe, lockable drawers with sliding channels, cupboard drapery hangers, curtain rods with end brackets, openable shutters with 19mm x 6mm thick plain teak wood beading, lipping 1.5mm thick commercial ply vertical support finished in approved 1.5mm lamination sheet of approved colour, shade and quality on all exposed surfaces. Inner surface painted with 2 coats of white synthetic enamel paint over 2 coats of Patti, one coat of wood primer, including cost of brass fittings, parliamentary hinges, C handles, tower bolts, magnetic catches, approved brand lock, adhesives, synthetic resins, nails, screws etc., complete including cost of all materials, labour charges, complete as per specification. (P.No.324, I.No. 39.3) | Sqm | 12042.24 | 12042.24 | 2.7 | False | None | None | False | None | False | 32514.048 | 0 | 3893876 | 149803 | None | 9.23 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white
cement slurry admixed with pigment of matching shade including rub bing, curing and polishingetc. all complete as specified and as directed by the Engineer-in-Charge :** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent. (P.No.63, I.No. 9.23) | Sqm | 2761.92 | 2761.92 | 3.0 | False | None | None | False | None | False | 8285.76 | 0 | 3893877 | 149803 | None | 11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Vol 2 It No 11.28 Pg no 83) | Kg | 632.8 | 632.8 | 100.0 | False | None | None | False | None | False | 63280.0 | 0 | 3893878 | 149803 | None | 2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Buildings( P.no. 18 I.No.2.11a)for first floor | t | 101193.76 | 101193.76 | 2.3849 | False | None | None | False | None | False | 241336.998224 | 0 | 3893879 | 149803 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labor, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) FOR ROOF SLAB(common sr it.no.2.5.2 of 2023-24)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for column | Cum | 13105.71 | 13105.71 | 4.14 | False | None | None | False | None | False | 54257.6394 | 0 | 3893880 | 149803 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labor, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) FOR ROOF SLAB(common sr it.no.2.5.2 of 2023-24)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for beam & lintel | Cum | 12339.3 | 12339.3 | 4.152 | False | None | None | False | None | False | 51232.7736 | 0 | 3893881 | 149803 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labor, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) FOR ROOF SLAB(common sr it.no.2.5.2 of 2023-24)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For staircase landing | Cum | 8507.22 | 8507.22 | 1.485 | False | None | None | False | None | False | 12633.2217 | 0 | 3893882 | 149803 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges up to 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labor, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) FOR ROOF SLAB(common sr it.no.2.5.2 of 2023-24)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for slabs | Cum | 11572.88 | 11572.88 | 10.644 | False | None | None | False | None | False | 123181.73472 | 0 | 3893883 | 149803 | None | 6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications (CSR Vol 2 It no:6.32 Pg No 17) | Sqm | 1481.87 | 1481.87 | 153.675 | False | None | None | False | None | False | 227726.37225 | 0 | 3893884 | 149803 | None | 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(It no:8.2.1, P.No 41 of Vol-2 SR 2022) | Sqm | 333.7 | 333.7 | 408.1 | False | None | None | False | None | False | 136182.97 | 0 | 3893885 | 149803 | None | 8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Vol-2 sr item num:8.25 P No 45) | Sqm | 154.97 | 154.97 | 290.74 | False | None | None | False | None | False | 45055.9778 | 0 | 3893886 | 149803 | None | 8.36.2 | Finishing with Epoxy paint (two coats) at all locations preparedand applied as per manufacturer's specifications including appropriatepriming coat, preparation of surface, etc. complete. On concrete workincluding preparing the surface after thorougly cleaning oil, grease,dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Vol-2 sr item num:8.36.2 P No 47) | Sqm | 194.57 | 194.57 | 117.36 | False | None | None | False | None | False | 22834.7352 | 0 | 3893887 | 149803 | None | 12.84 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made). ( P.no.110, I.no12.84) | Sqm | 5682.02 | 5682.02 | 11.61 | False | None | None | False | None | False | 65968.2522 | 0 | 3893888 | 149803 | None | 9.96 | Providing and fixing 65mmx125mm GRP Doorframe fabricated using E-Giass Chopped Strand Mat (CSM) U.V- stabilized lsopthalic Gelcoat and lsopthalic resin. The thickness of the GRP skin shall not be less than 2.0mm. The doorframe consists of four segments, which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screws. The GRP frame shall be provided with wooden reinforcement on 6 locations for high screw holding capacity for fixing metalling hold fast and shall be consolidated by filling with medium density foam/Plaster of Paris with fibre reinforcement Six Numbers of 260mmx25mmx5mm sizeS shaped M.S. flat hold fast shall be provided with the frame.( SR 18-19 Item.no:-9.96) | m | 622.16 | 622.16 | 31.2 | False | None | None | False | None | False | 19411.392 | 0 | 3893889 | 149803 | None | 9.93 | Providing and fixing factory made single leaf rigid GRP Sandwich composite door shutter of 32mm thick, laminated with two GRP skins with wood grain finish, fabricated using U.V-stabilized lsopthalic Gelcoat and on layer of 45 gsm E-Giass Chopped strand Mat (CSM), impregnated with orthopthalic polyster resin. The thickness of the skins shall not be less than 1.5mm. Expanded Polystyrene (EPS) structural foam panel of 29mm thickness and a density of 20 Kg/m3 shall be used as core material. Wooden reinforcements made of Seasoned Salwood block of cross section not less than 28mmx32mm and also necessary salwood reinforcements for fixing the metal fittings such as tower bolts, aldrops, handles, etc, shall be provided. A structural adhesive compatible with EPS foam shall be used for bonding the core material, the Salwood reinforcement and the skins. The material and process for manufacturing the door shutters shall confirm to Standards and specifications and the door shutters tested in confiramation to IS 4020-1994. The finish of shutter will be plain colour White/Ivory/Beige/Light Grey or any other colour using high quality pigments. Exclusing cost of fixtures and inclusive of supply of shutters to respective work spot.(SR 2018-19 Item.no:-9.93) | Sqm | 3360.0 | 3360.0 | 10.71 | False | None | None | False | None | False | 35985.6 | 0 | 3893890 | 149803 | None | 9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm ( P.no.60 I.no.9.12.2 ) | Sqm | 1295.22 | 1295.22 | 69.39 | False | None | None | False | None | False | 89875.3158 | 0 | 3893891 | 149803 | None | 11.34B | Providing and fixing M.S. grills of required pattern in frames of win dows etc. with M.S. flats, squareor round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc( SR Vol-2/P.no. 85 I.No.11.34B) | Kg | 207.01 | 207.01 | 168.75 | False | None | None | False | None | False | 34932.9375 | 0 | 3893892 | 149803 | None | 11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts,fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Vol 2 It No 11.28 Pg no 83) | Kg | 639.13 | 639.13 | 100.0 | False | None | None | False | None | False | 63913.0 | 0 | 3893893 | 149803 | None | 14.3.1 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid.( P.no.122 I.no.14.3.1) | No | 6761.18 | 6761.18 | 2.0 | False | None | None | False | None | False | 13522.36 | 0 | 3893894 | 149803 | None | 14.7.1 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. ( P.N 124 In:14.7.1) | No | 3486.36 | 3486.36 | 2.0 | False | None | None | False | None | False | 6972.72 | 0 | 3893895 | 149803 | None | 13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.(2023-24 sr Vol 2 it no 13.34 pg 123) | Ltr | 10.18 | 10.18 | 2000.0 | False | None | None | False | None | False | 20360.0 | 0 | 3893896 | 149803 | None | 11.16.2 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(It no:11.16.2 Pg.No:-81 of Vol-2 SR 2023-24) | Kg | 167.93 | 167.93 | 19.728 | False | None | None | False | None | False | 3312.92304 | 0 | 3893897 | 149803 | None | 7.38 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.(It no:7.38, P.No 26 of Vol-2 SR 2022) | Sqm | 642.52 | 642.52 | 8.32 | False | None | None | False | None | False | 5345.7664 | 0 | 3893898 | 149803 | None | 15.10 | Polyurethane based Single Component for New SurfaceProviding and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU wa terproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the wa terproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.(It no:15.10, P.No 149 of Vol-2 SR 2023-24) | Sqm | 924.19 | 924.19 | 69.76 | False | None | None | False | None | False | 64471.4944 | 0 | 3893899 | 149803 | None | 1.1.1 | Open Conduit System Supplying heavy gauge PVC conduit pipe …….dia .mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.a)19/20mm dia 2mm thick (It.no.1.1.1& P.no.2) | Mtr | 69.0 | 69.0 | 100.0 | False | None | None | False | None | False | 6900.0 | 0 | 3893900 | 149803 | None | 1.3.1 | Supplying heavy gauge PVC Conduit Pipe ….dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.a)19/20mm dia 2mm thick(It.no.1.3.1 & P.no.2) | Mtr | 68.0 | 68.0 | 70.0 | False | None | None | False | None | False | 4760.0 | 0 | 3893901 | 149803 | None | 2.2.1 | Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.a)Short point upto 3Mtr from tapping point to out let via switch box (It.no.2.2.1& P.no.5) | Point | 269.0 | 269.0 | 10.0 | False | None | None | False | None | False | 2690.0 | 0 | 3893902 | 149803 | None | 2.2.2 | Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.b)Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch box (It.no.2.2.2 & P.no.5) | Point | 379.0 | 379.0 | 8.0 | False | None | None | False | None | False | 3032.0 | 0 | 3893903 | 149803 | None | 2.2.3 | Point wiring using Copper wire without switch.Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.c)Long point above 6Mtr upto 10Mtr from tapping point to out let via switch box (It.no.2.2.3 & P.no.5) | Point | 555.0 | 555.0 | 5.0 | False | None | None | False | None | False | 2775.0 | 0 | 3893904 | 149803 | None | 2.3.1 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.a)1.0 sqmm (It.no.2.3.1& P.no.5) | Mtr | 19.0 | 19.0 | 140.0 | False | None | None | False | None | False | 2660.0 | 0 | 3893905 | 149803 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.b)1.5 sqmm (It.no.2.3.2& P.no.5) | Mtr | 26.0 | 26.0 | 250.0 | False | None | None | False | None | False | 6500.0 | 0 | 3893906 | 149803 | None | 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.c)2.5 sqmm (It.no.2.3.3 & P.no.5) | Mtr | 42.0 | 42.0 | 500.0 | False | None | None | False | None | False | 21000.0 | 0 | 3893907 | 149803 | None | 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.d)4.0 sqmm (It.no.2.3.4 & P.no.5) | Mtr | 63.0 | 63.0 | 150.0 | False | None | None | False | None | False | 9450.0 | 0 | 3893908 | 149803 | None | 2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.e)6.0 sqmm (It.no.2.3.5 & P.no.5) | Mtr | 92.0 | 92.0 | 50.0 | False | None | None | False | None | False | 4600.0 | 0 | 3893909 | 149803 | None | 3.4.3 | Supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.a)4-5 Way(It.no.3.4.3 & P.no.8) | Each | 177.0 | 177.0 | 5.0 | False | None | None | False | None | False | 885.0 | 0 | 3893910 | 149803 | None | 3.4.4 | Supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.b)6 Way(It.no.3.4.4 & P.no.8) | Each | 220.0 | 220.0 | 3.0 | False | None | None | False | None | False | 660.0 | 0 | 3893911 | 149803 | None | 3.4.5 | Supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.c)8 Way(It.no.3.4.5 & P.no.8) | Each | 261.0 | 261.0 | 2.0 | False | None | None | False | None | False | 522.0 | 0 | 3893912 | 149803 | None | 3.4.6 | Supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall.d)10-12 Way(It.no.3.4.6 & P.no.8) | Each | 319.0 | 319.0 | 2.0 | False | None | None | False | None | False | 638.0 | 0 | 3893913 | 149803 | None | 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.a)6Amps one way Switch(It.no.3.6.1 & P.no.9) | Each | 102.0 | 102.0 | 15.0 | False | None | None | False | None | False | 1530.0 | 0 | 3893914 | 149803 | None | 3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.b)6Amps 3way socket(It.no.3.6.3 & P.no.9) | Each | 171.0 | 171.0 | 7.0 | False | None | None | False | None | False | 1197.0 | 0 | 3893915 | 149803 | None | 3.6.4 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.c)Stepped Fan Regulator Two Module(It.no.3.6.4 & P.no.9) | Each | 357.0 | 357.0 | 3.0 | False | None | None | False | None | False | 1071.0 | 0 | 3893916 | 149803 | None | 3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.d)32A DP Switch(It.no.3.6.10 & P.no.9) | Each | 326.0 | 326.0 | 4.0 | False | None | None | False | None | False | 1304.0 | 0 | 3893917 | 149803 | None | 3.14.5 | Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board.a)6A Bakelite Ceiling Rose.(It.no.3.14.5& P.no.10) | No | 78.0 | 78.0 | 5.0 | False | None | None | False | None | False | 390.0 | 0 | 3893918 | 149803 | None | 3.14.7 | Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board.b)6A Batten Holder.(It.no.3.14.7 & P.no.10) | No | 74.0 | 74.0 | 10.0 | False | None | None | False | None | False | 740.0 | 0 | 3893919 | 149803 | None | 5.18.1 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using ecessary fixingmaterials and 'C'Type curve, indicator ON/OFF,energy cross-3with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.a)6-32 A SP(It,no.5.18.1 & P.no.17) | No | 415.0 | 415.0 | 4.0 | False | None | None | False | None | False | 1660.0 | 0 | 3893920 | 149803 | None | 13.18.1 | Fixingof.ATPST/changeover switch/ Contactor along with neutral link with screws,bolts,nuts and wiring using required capacity wires and circuit labelling.a)15A to 63A TPST(It,no.13.18.1 & P.no.57) | Each | 278.0 | 278.0 | 2.0 | False | None | None | False | None | False | 556.0 | 0 | 3893921 | 149803 | None | 11.3.2 | Supplyingof.feet-C Batten with integrated LED tube.W with high quality diffuser with Life of 25000 burning hours& 70% lumen maintenance with CRI greaterthan80.Power Input:220-240V@50/60Hz&Powerfactor greaterthan 0.9along with CE approved. 2years Warranty against any manufacturing defect working understandard electrical condition.a)LED light fitting 1 x 4' - 20/22 W(It,no.11.3.2 & P.no.43) | Each | 690.0 | 690.0 | 10.0 | False | None | None | False | None | False | 6900.0 | 0 | 3893922 | 149803 | None | 11.11.5 | Supplying & fixing of retrofit type - LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIgreaterthan70%. efficacy greaterthan 80 lumen per watt, life greaterthan 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greaterthan 0.95, power loss should lesserthan5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.a)12W, 6500K(It,no.11.11.5 & P.no.47) | Each | 269.0 | 269.0 | 5.0 | False | None | None | False | None | False | 1345.0 | 0 | 3893923 | 149803 | None | 6.4.1 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment, Rated voltage 220 V/ 50 Hz, Rated power input 48 W +/-10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value greaterthan or equal4.2 CMM / Watt, Three Blades of blade leaf 1.05mm thick luminium Alloy sheet,Class B motorinsulation,Bearing Two ball bearings, Top 6202, Bottom 6201 , as per IS specification, Motor wdg. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245Volts, Insulation resistance Shall not be less than Two Mega Ohms (2 M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, watt& current , Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.a)48" Sweep 5 Star (1200 mm)(It,no.6.4.1 & P.no.23) | Each | 2949.0 | 2949.0 | 3.0 | False | None | None | False | None | False | 8847.0 | 0 | 3893924 | 149803 | None | 12.6 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x 400mm with a cast iron cover.The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.(It.no.12.6 & P.no.54) | No | 4256.0 | 4256.0 | 5.0 | False | None | None | False | None | False | 21280.0 | 0 | 3893925 | 149803 | None | 7.1.2 | Supplying.litres capacity vertical/horizontal type wall mountingElectrical water heater with 22 SWG copper/SS sheet metal innerContainer tinned inside and anticorrosive paint outside and 20 SWGM.S. sheet metal outer cover filled with glass wool between inner andouter container for thermal insulation complete. The inlet and outletpipes so arranged that water flow inside results in water to flow outfrom the inner container without turbulence. The Inner container shallhave direct immersion type copper tube nickel plate. 2kW capacityelement with a neonindicator fitted with 20A capacity 25 to 85 degreeCentigrade range thermostat. The water heater shall completely bewired with40/0.0076 inch 3 core copperflexible wire of 1.5 meterslength and the outer container provided with heavy gauge brackets forwall mounting.(It.no.7.1.2 ) | No | 8765.0 | 8765.0 | 3.0 | False | None | None | False | None | False | 26295.0 | 0 | 3893926 | 149803 | None | code | Providing and installing power reading meter with necessary wiring,grounding and installation and charges etc.complete.(Including GST) | Cum | 27000.0 | 27000.0 | 1.0 | False | None | None | False | None | False | 27000.0 | 0 |
|