3827121 | 145775 | None | 001 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 m, PWD DSR 2023-24 Volume-I Page No. 6 Item No. 1.14.1 | Cum | 107.1 | 107.1 | 112.21 | False | None | None | False | None | False | 12017.691 | 0 |
3827122 | 145775 | None | 002 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications - Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates PWD CSR 2023-24, Vol-I, P. No. 15, I. No. 2.1.3 | Cum | 6288.45 | 6288.45 | 10.14 | False | None | None | False | None | False | 63764.883 | 0 |
3827123 | 145775 | None | 003 | Providing Random rubble masonry with hard stone in foundation and
plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand)(PWD DSR 2023-24, Volume-I Page No. 9, Item No. 5.1.1) | Cum | 5891.55 | 5891.55 | 33.3 | False | None | None | False | None | False | 196188.615 | 0 |
3827124 | 145775 | None | 004 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)(PWD DSR 2023-24, Volume-I Page No. 9, Item No. 5.2) | Cum | 6948.9 | 6948.9 | 6.97 | False | None | None | False | None | False | 48433.833 | 0 |
3827125 | 145775 | None | 005 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.( PWD DSR 2023-24 Volume-II Page No. 7 Item No. 1.9) | Cum | 279.3 | 279.3 | 64.91 | False | None | None | False | None | False | 18129.363 | 0 |
3827126 | 145775 | None | 006 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. PWD DSR 2023-24 Volume-I Page No. 9 Item No. 2.2.1 | Cum | 6601.35 | 6601.35 | 8.86 | False | None | None | False | None | False | 58487.961 | 0 |
3827127 | 145775 | None | 007 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.PWD DSR 2023-24 Volume-I Page No. 9 Item No. 2.3.1 | Cum | 6639.15 | 6639.15 | 8.08 | False | None | None | False | None | False | 53644.332 | 0 |
3827128 | 145775 | None | 008 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.PWD DSR 2023-24 Volume-I Page No. 9 Item No. 2.5.1 | Cum | 6961.5 | 6961.5 | 27.4 | False | None | None | False | None | False | 190745.1 | 0 |
3827129 | 145775 | None | 009 | Form work Foundation upto Plinth(Isolated)(PWD DSR 2021-22 Volume-I Page No. 111 Item No.1(a) 8% OF CONCRETE RATE) | Cum | 528.11 | 528.11 | 8.86 | False | None | None | False | None | False | 4679.0546 | 0 |
3827130 | 145775 | None | 010 | Form work Foundation uptoPlinth Beams of Buildings and RCC Roof Slabs (PWD DSR 2021-22 Volume-I Page No. 111 Item No.2. 50% OF CONCRETE RATE) | Cum | 3319.58 | 3319.58 | 8.08 | False | None | None | False | None | False | 26822.2064 | 0 |
3827131 | 145775 | None | 011 | Form work Foundation upto RCC Roof Slabs (PWD DSR 2021-22 Volume-I Page No. 111 Item No.2. 50% OF CONCRETE RATE) | Cum | 3480.75 | 3480.75 | 14.81 | False | None | None | False | None | False | 51549.9075 | 0 |
3827132 | 145775 | None | 012 | Form work Foundation uptoRCC Beams, Lintels & Troughs of Aqueducts(PWD DSR 2021-22 Volume-I Page No. 111 Item No.2. 50% OF CONCRETE RATE) | Cum | 4176.9 | 4176.9 | 6.42 | False | None | None | False | None | False | 26815.698 | 0 |
3827133 | 145775 | None | 013 | Form work Foundation uptoRCC Columns / Shaft (Slip Centering)(PWD DSR 2021-22 Volume-I Page No. 111 Item No.2. 70% OF CONCRETE RATE) | Cum | 4873.05 | 4873.05 | 5.51 | False | None | None | False | None | False | 26850.5055 | 0 |
3827134 | 145775 | None | 014 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (All other type of structures).PWD DSR 2023-24 Volume-I Page No. 18, Item No. 2.11h | Tonne | 93929.85 | 93929.85 | 3.694 | False | None | None | False | None | False | 346976.8659 | 0 |
3827135 | 145775 | None | 015 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.(PWD DSR 2023-24 Volume-II Page No. 13 Item No. 6.2 | Cum | 8376.9 | 8376.9 | 33.57 | False | None | None | False | None | False | 281212.533 | 0 |
3827136 | 145775 | None | 016 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(PWD DSR 2023-24 Volume-II Page No.41,Item No. 8.2.1) | Sqm | 309.75 | 309.75 | 485.55 | False | None | None | False | None | False | 150399.1125 | 0 |
3827137 | 145775 | None | 017 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.(PWD DSR 2023-24 Volume-II Page No.44,Item No. 8.19.1) | Sqm | 267.75 | 267.75 | 18.4 | False | None | None | False | None | False | 4926.6 | 0 |
3827138 | 145775 | None | 018 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser, treads of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints as per direction of Engineer in charge.(PWD DSR 2023-24 Volume-II Page No.44,Item No. 8.19.1) | Sqm | 1231.65 | 1231.65 | 67.6 | False | None | None | False | None | False | 83259.54 | 0 |
3827139 | 145775 | None | 019 | Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge(PWD DSR 2023-24 Volume-II Page No.44,Item No. 8.19.1) | Sqm | 27.3 | 27.3 | 172.02 | False | None | None | False | None | False | 4696.146 | 0 |
3827140 | 145775 | None | 020 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(PWD DSR 2023-24 Volume-II Page No.44,Item No.8.25) | Sqm | 143.85 | 143.85 | 172.02 | False | None | None | False | None | False | 24745.077 | 0 |
3827141 | 145775 | None | 021 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.(PWD DSR 2023-24 Volume-II Page No.86,Item No.8.25) | Sqm | 192.15 | 192.15 | 194.04 | False | None | None | False | None | False | 37284.786 | 0 |
3827142 | 145775 | None | 022 | Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)(PWD DSR 2023-24 Volume-II Page No.100,Item No.12.15) | Sqm | 7241.85 | 7241.85 | 2.25 | False | None | None | False | None | False | 16294.1625 | 0 |
3827143 | 145775 | None | 023 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.(PWD DSR 2023-24 Volume-II Page No.99,Item No.12.12) | Cum | 130412.1 | 130412.1 | 0.216 | False | None | None | False | None | False | 28169.0136 | 0 |
3827144 | 145775 | None | 024 | PVC liner material(including import duty ,freight charges) PVC pipe - OD 32mm and 10 Kg/sqcm | Rmtr | 34.65 | 34.65 | 40.0 | False | None | None | False | None | False | 1386.0 | 0 |
3827145 | 145775 | None | 025 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. PWD CSR 2023-24, Vol-II, P. No. 123, I. No. 13.34 | Ltr | 9.45 | 9.45 | 1500.0 | False | None | None | False | None | False | 14175.0 | 0 |
3827146 | 145775 | None | 026 | SupplyingheavygaugePVCconduitpipe.dia.mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws.PWD ELE CSR 2023-24, Vol-VI, P. No.105, I. No.1.1.1 | Rmtr | 72.45 | 72.45 | 40.0 | False | None | None | False | None | False | 2898.0 | 0 |
3827147 | 145775 | None | 027 | Supplyingandflushmountingpowdercoated/galvanizedmetalboxsuitableformountingmodularswitchplates.Theboxshouldbefirmlyflush mounted after due groove cutting in Brick/Stone/C.C wall(PWD ELE CSR 2023-24, Vol-VI, P. No.105, I. No.1.1.1) | Rmtr | 144.9 | 144.9 | 40.0 | False | None | None | False | None | False | 5796.0 | 0 |
3827148 | 145775 | None | 028 | Supplyingandflushmountingteakwoodenboxwithoutfrontplank,madeofnotlessthan12mmthickwood,afterduegroovecutting,finishing with necessary cement plastering complete.12" x 12" x 3" (300 x 300 x 76 mm) PWD ELE 2023-24 pg no 3 of 105, It no 1.6.1 | Rmtr | 126.0 | 126.0 | 8.0 | False | None | None | False | None | False | 1008.0 | 0 |
3827149 | 145775 | None | 029 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm 2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC roundblock. complete for each outlet.PWD ELE 2021-22 pg no 2 It no 2.1.1 | Rmtr | 289.8 | 289.8 | 10.0 | False | None | None | False | None | False | 2898.0 | 0 |
3827150 | 145775 | None | 030 | Mediumpointabove3Mtrupto6Mtrfromtappingpointtooutletviaswitch. (PWD ELE 2023-24 pg no 3 of 105, It no 2.1.2) | Each | 413.7 | 413.7 | 4.0 | False | None | None | False | None | False | 1654.8 | 0 |
3827151 | 145775 | None | 031 | C)Longpointabove6Mtrupto10Mtrfromtappingpointtooutletviaswitch.(PWD ELE 2023-24 pg no 3 of 105, It no 2.1.2) | Each | 598.5 | 598.5 | 4.0 | False | None | None | False | None | False | 2394.0 | 0 |
3827152 | 145775 | None | 032 | Supplyingandfixinghylumplasticsheet3mmthickwithnecessarynitchesforfixingswitches,regulatorsetc.,andfixingonexistingwood or metal box using N. F. screws.(PWD ELE 2023-24 pg no 3 of 105, It no 3.9) | Each | 0.37 | 0.37 | 1000.0 | False | None | None | False | None | False | 370.0 | 0 |
3827153 | 145775 | None | 033 | Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board.6A Two Way Switch.(PWD ELE 2023-24 pg no 3 of 105, It no3.14.2) | Each | 73.5 | 73.5 | 4.0 | False | None | None | False | None | False | 294.0 | 0 |
3827154 | 145775 | None | 034 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring asrequired confirming to IEC 60898. 6-32 A TPN PWD ELE 2021-22 pg no 13 It no 5.17.7 | Each | 1865.85 | 1865.85 | 4.0 | False | None | None | False | None | False | 7463.4 | 0 |
3827155 | 145775 | None | 035 | SupplyingofCeilingFanwithCapacitorratingAsperguidelineofBEE5starratingandIS:374/19andalsocomplywithIS:1709/1984withlatestamendment,Ratedvoltage220V/50Hz,Ratedpowerupto35W+/10%,RatedcurrentAsperIS:374/19,Ratedpowerfactor0.9lagging(min),Ratedspeed350+/10%RPM,Ratedairdelivery210+/10%CubicMeterMinimum,Ratedservicevalue6.2CMM/W,ThreeBladesofbladeleaf1.05mmthickAluminiumAlloysheet,ClassBmotorinsulation,BearingTwoballbearings,Top6202,Bottom6201,asperISspecification,Motorwinding.TempriseShallnotexceed75degCoverandambientof400Cbyresistancemethodat245V,InsulationresistanceShallnotbelessthanTwoMegaOhms(2MOhms),LeakagecurrentShouldnotexceed210MicroAmp,Powerinput,W¤t,AirDelivery&FanSpeedasperIS:374/2019withlatestamendment,2yearmanufacturerWarranty.(BLDC fans)48" Sweep 5 Star (1200 mm)(PWD ELE 2023-24 pg no 3 of 105, It no3.14.2) | No | 2810.85 | 2810.85 | 4.0 | False | None | None | False | None | False | 11243.4 | 0 |
3827156 | 145775 | None | 036 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring PWD ELE 2021-22 pg no 23 It no 6.4 | No | 170.1 | 170.1 | 4.0 | False | None | None | False | None | False | 680.4 | 0 |
3827157 | 145775 | None | 037 | Fixingalltypesandallcapacitiesoffluorescent/falseceiling/spotlight/CFL/LEDfittingsindooronthewall/ceiling/rafters/girdersusing23/0.0076"twintwistedPVCinsulatedwires,requiredNosofround blocks and clamps.On wall/ ceiling / Rafter / Girders(PWD ELE 2023-24 pg no 3 of 105, It no3.14.2) | No | 128.1 | 128.1 | 4.0 | False | None | None | False | None | False | 512.4 | 0 |
3827158 | 145775 | None | 038 | Supplyandfixingpolishedwoodboardmadeofnotlessthan15mmthickplankonbothsidesofnotmorethan2piecesandfixingthesametothewallusingtaperedinvertedwoodenplugsscrews.12" x 12" x 2"(PWD ELE 2023-24 pg no 14 of 105, It no 5.6.4) | No | 190.05 | 190.05 | 2.0 | False | None | None | False | None | False | 380.1 | 0 |
3827159 | 145775 | None | 039 | Supplying and fixing of porcelain fuse channel with cut out 16 Amps on existing wooden/panel using necessary nuts, bolts, and washers etc complee (32/3)(PWD ELE 2023-24 pg no 62 of 105, It no 14.04) | No | 144.9 | 144.9 | 5.0 | False | None | None | False | None | False | 724.5 | 0 |
3827160 | 145775 | None | 040 | SupplyingofSwitchdisconnectorfuseunit(TPN)HRCtype(butwithout HRC fuses). With AC-23A duty and as per IS- 13947.63 A(PWD ELE 2023-24 pg no 15 of 105, It no 5.8.1) | No | 2427.6 | 2427.6 | 1.0 | False | None | None | False | None | False | 2427.6 | 0 |
3827161 | 145775 | None | 041 | SupplyofLEDpolemountingtypeposttoplanternwithpressurediecastaluminiumhousingbodyforoptimalthermaldissipation.LampcompartmentcomprisingofantiglarecleardiffuserwithInjectionmouldedpolycarbonate/clearglassmaterial,deliveringsuperiorlightoutputRatedlifeBurningHrs50000hr at LumenMaintenanceof70,CCT5500K,IP66opticalandelectricalcompartment&impactresistanceofcompleteluminaireIK08.PowerFactor0.9withmains,SurgeProtectionMin5KValongwithOvervoltageOverload,shortcircuitmisswiringprotection.Compatibleforpolemountingwithouterdiaof40mmto50mm.UniversalVoltagedrivertooperatewidevoltagerangefrom100Vto270V5060Hzapplication.CompliancetoIS10322/1EC60598,LM79LM80AdherencewithRoHS.ULapprovedMCPCBLEDEfficiency1301m w,nominalCRI75.LuminairemanufacturershouldhaveinhousefacilityaccreditedbyNABL/CPRI&anyGovernmentcertifiedagency&Design&DevelopmentfacilitycertifiedbyISO9001:2008.Housingwithsupplierwordmark/nameshallbeEngraved/Embossingonthediecasthousing/BodypartWarrantyof2YearsagainstanymanufacturingdefectworkingunderstandardelectricalconditionsasmentionedaboveshouldbegivenbyLEDmanufacturer&Cree/Nichia/Lumileds/Osrammake LED Source.LED Post Top Lantern with 25/30 W(PWD ELE 2023-24 pg no 45 of 105, It no11.7.2) | No | 8108.1 | 8108.1 | 1.0 | False | None | None | False | None | False | 8108.1 | 0 |
3827162 | 145775 | None | 042 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life) PWD CSR 2023-24, Vol-II, P. No. 46, I. No. 8.33.1 | Sqm | 165.9 | 165.9 | 313.53 | False | None | None | False | None | False | 52014.627 | 0 |
3827163 | 145775 | None | 043 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2 including pointing in white cement mixed with pigment of matching shade complete. PWD CSR 2023-24, Vol-II, P. No. 60, I. No. 9.10 | Sqm | 1161.3 | 1161.3 | 99.53 | False | None | None | False | None | False | 115584.189 | 0 |
3827164 | 145775 | None | 044 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. PWD CSR 2023-24, Vol-II, P. No. 63, I. No. 9.24 | Sqm | 2994.6 | 2994.6 | 1.56 | False | None | None | False | None | False | 4671.576 | 0 |
3827165 | 145775 | None | 044 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance 1mm), with wall thickness 2.0 mm ( 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (0.1 mm) wall thickness and 3 nos.stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge 42x50 mm PVC Extruded section PWD CSR 2023-24, Vol-II, P. No. 108, I.No.12.83.2 | Mtr | 250.95 | 250.95 | 75.0 | False | None | None | False | None | False | 18821.25 | 0 |
3827166 | 145775 | None | 046 | Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) PWD CSR 2023-24, Vol-II, P. No. 111, I. No. 12.92 | Sqm | 6557.25 | 6557.25 | 23.94 | False | None | None | False | None | False | 156980.565 | 0 |
3827167 | 145775 | None | 047 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) PWD CSR 2023-24, Vol-II, P. No. 108, I. No. 12.84 | Sqm | 5173.69 | 5173.69 | 1.8 | False | None | None | False | None | False | 9312.642 | 0 |
3827168 | 145775 | None | 048 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) PWD CSR 2023-24, Vol-II, P. No. 109, I. No. 12.85 | Sqm | 6004.95 | 6004.95 | 1.62 | False | None | None | False | None | False | 9728.019 | 0 |
3827169 | 145775 | None | 049 | Water proofing materials PWD CSR 2023-24, Vol-II, P. No.A-43 I. No.1028 | Kg | 46.2 | 46.2 | 50.0 | False | None | None | False | None | False | 2310.0 | 0 |
3827170 | 145775 | None | 050 | Providing and fixing unplasticised PVC connection pipe with brass unions :45 cm length, 20mm NB PWD CSR 2023-24, Vol-II, P. No. 118, I. No. 13.8.2.2 | No | 115.5 | 115.5 | 12.0 | False | None | None | False | None | False | 1386.0 | 0 |
3827171 | 145775 | None | 051 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. PWD CSR 2023-24, Vol-II, P. No. 122, I. No. 13.32.3 25 mm nominal dia pipes | Rmtr | 500.85 | 500.85 | 30.0 | False | None | None | False | None | False | 15025.5 | 0 |
3827172 | 145775 | None | 052 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work PWD CSR 2023-24, Vol-II, P. No. 122, I. No. 13.33.4 32 mm nominal dia Pipes | Rmtr | 390.6 | 390.6 | 20.0 | False | None | None | False | None | False | 7812.0 | 0 |
3827173 | 145775 | None | 053 | Providing and fixing on wall face unplasticised rigid PVC rain water pipes conforming to IS 13592 type A, including jointing with seal ring conforming to IS 5382, leaving 10mm gap for thermal expansion, (i) single socketed pipes 100 mm diameter PWD CSR 2023-24, Vol-II, P. No. 125, I. No. 13.48 | Rmtr | 305.55 | 305.55 | 40.0 | False | None | None | False | None | False | 12222.0 | 0 |
3827174 | 145775 | None | 054 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete PWD CSR 2023-24, Vol-II, P. No. 127, I. No. 13.59 | No | 226.6 | 226.6 | 12.0 | False | None | None | False | None | False | 2719.2 | 0 |
3827175 | 145775 | None | 055 | Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge Orissa pattern W.C Pan of size 580x440 mm (PWD CSR 2023-24, Vol-II, P. No. 202, I. No. 20.44.2) | No | 3653.41 | 3653.41 | 12.0 | False | None | None | False | None | False | 43840.92 | 0 |
3827176 | 145775 | None | 056 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps PWD CSR 2023-24, Vol-II, P. No. 132, I. No. 14.7.1 | Each | 3236.1 | 3236.1 | 2.0 | False | None | None | False | None | False | 6472.2 | 0 |
3827177 | 145775 | None | 057 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 1500x450 mm (PWD CSR 2023-24, Vol-II, P. No. 136, I. No. 14.32.4) | Each | 1812.3 | 1812.3 | 2.0 | False | None | None | False | None | False | 3624.6 | 0 |
3827178 | 145775 | None | 058 | Providing and fixing Bib cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete Economy Class PWD CSR 2023-24, Vol-II, P. No. 139, I. No. 14.55a | No | 1150.51 | 1150.51 | 14.0 | False | None | None | False | None | False | 16107.14 | 0 |
3827179 | 145775 | None | 059 | Providing and installing at site of work P.V.C. pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof includingjointing of approved type with all labour charges and all lift charges, handling charges including encasing the pipe around to a depth not less than 15 cms with gravel or selected earth available from theexcavationetc. complete. 6 Kg/m2: 200mm(weight of pipe -6.233 kg) (p.no.120. it.no 10.14.14) 2023-24 WATER SUPPLY AND UGD WORKS COMMON SCHEDULE OF RATES VOLUME-V | Rmtr | 1015.35 | 1015.35 | 40.0 | False | None | None | False | None | False | 40614.0 | 0 |
3827180 | 145775 | None | 060 | Concealed PVC Conduit System Supplying heavy gauge PVC Conduit Pipe . dia . mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 19/20 mm dia 2mm thick (P.no.2.it.no.1.1.1) (PWD CSR for Electrical Works for the Year 2023-24) | m | 72.45 | 72.45 | 70.0 | False | None | None | False | None | False | 5071.5 | 0 |
3827181 | 145775 | None | 061 | PVC/metal conduit Deep Junction Box Supplying and fixing PVC/metal conduit Deep junction box 19/20mm Deep Junction Box (P.no.2.it.no.1.5) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 51.45 | 51.45 | 10.0 | False | None | None | False | None | False | 514.5 | 0 |
3827182 | 145775 | None | 062 | Flush Mounting Wooden Box Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 8" x 6" x 3" (203 x 152 x 76 mm) (P.no.3.it.no.1.6.4) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 90.3 | 90.3 | 6.0 | False | None | None | False | None | False | 541.8 | 0 |
3827183 | 145775 | None | 063 | Flush Mounting Wooden Box Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 4" x 4" x 3" ( 101 x 101 x 76 mm) (P.no.3.it.no.1.6.6) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 77.7 | 77.7 | 24.0 | False | None | None | False | None | False | 1864.8 | 0 |
3827184 | 145775 | None | 064 | Wiring for Lightings/Power Circuit Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.1.5 Sqmm (P.no.5.it.no.2.3.2) (PWD CSR for Electrical Works for the Year 2023-24) | Mtr | 27.3 | 27.3 | 250.0 | False | None | None | False | None | False | 6825.0 | 0 |
3827185 | 145775 | None | 065 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.2.5 Sqmm (P.no.5.it.no.2.3.3) (PWD CSR for Electrical Works for the Year 2023-24) | Mtr | 44.1 | 44.1 | 200.0 | False | None | None | False | None | False | 8820.0 | 0 |
3827186 | 145775 | None | 066 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.4 Sqmm (P.no.5.it.no.2.3.4) (PWD CSR for Electrical Works for the Year 2023-24) | Mtr | 66.15 | 66.15 | 125.0 | False | None | None | False | None | False | 8268.75 | 0 |
3827187 | 145775 | None | 067 | Modular Switches/Sockets/Regulators etc Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps one way (P.no.9.it.no.3.6.1) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 107.1 | 107.1 | 14.0 | False | None | None | False | None | False | 1499.4 | 0 |
3827188 | 145775 | None | 068 | Modular Switches/Sockets/Regulators etc Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 6Amps two way. (P.no.9.it.no.3.6.2) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 166.0 | 166.0 | 4.0 | False | None | None | False | None | False | 664.0 | 0 |
3827189 | 145775 | None | 069 | Modular Switches/Sockets/Regulators etc Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 16Amps one way switch (P.no.9.it.no.3.6.7) .(PWD CSR for Electrical Works for the Year 2023-24) | Each | 189.0 | 189.0 | 5.0 | False | None | None | False | None | False | 945.0 | 0 |
3827190 | 145775 | None | 070 | Modular Switches/Sockets/Regulators etc Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293 32Amps DP switch. (P.no.9.it.no.3.6.9) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 342.3 | 342.3 | 4.0 | False | None | None | False | None | False | 1369.2 | 0 |
3827191 | 145775 | None | 071 | 4mm Thick Plastic Sheets Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc, and fixing on existing wooden or metal box using N.F. screws. (P.no.9.it.no.3.8) (PWD CSR for Electrical Works for the Year 2023-24) | 2 Cmtr | 0.43 | 0.43 | 200.0 | False | None | None | False | None | False | 86.0 | 0 |
3827192 | 145775 | None | 072 | Porcelain Fuse Channel Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 32Amps (P.no.10.it.no.5.7.2) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 253.05 | 253.05 | 2.0 | False | None | None | False | None | False | 506.1 | 0 |
3827193 | 145775 | None | 073 | Miniature Circuit Breakers Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps SP (p.no.17.it.no.5.18.1) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 435.75 | 435.75 | 2.0 | False | None | None | False | None | False | 871.5 | 0 |
3827194 | 145775 | None | 074 | Miniature Circuit Breakers Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps DP .(p.no.17.it.no.5.18.4) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 775.95 | 775.95 | 2.0 | False | None | None | False | None | False | 1551.9 | 0 |
3827195 | 145775 | None | 075 | MCB Distribution Boards Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.I - Single Door 8 Way SP & N (p.no.18.it.no.5.19.3)(PWD CSR for Electrical Works for the Year 2023-24) | Each | 1566.6 | 1566.6 | 2.0 | False | None | None | False | None | False | 3133.2 | 0 |
3827196 | 145775 | None | 076 | PVC Batten with LED Tubes Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V 5060Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fighting 1 x4- 20/22 w (p.no.43.it.no.11.3.2) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 724.5 | 724.5 | 12.0 | False | None | None | False | None | False | 8694.0 | 0 |
3827197 | 145775 | None | 077 | LED Down Lights Supply of round/square recess/surface mounted rolling type LED Down light with .W GU 10 LED Lamp Rib Fabricated from Die cast aluminium with white powder coated prewired to mains connector & has swiveling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V 5060Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18W (p.no.43.it.no.11.5.3) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 1390.2 | 1390.2 | 2.0 | False | None | None | False | None | False | 2780.4 | 0 |
3827198 | 145775 | None | 078 | Lamp Holder Supplying & Fixing of 70-150 Watts lamp holder 2 Pin (p.no.52.it.no.12.46) (PWD CSR for Electrical Works for the Year 2023-24) | No | 66.15 | 66.15 | 12.0 | False | None | None | False | None | False | 793.8 | 0 |
3827199 | 145775 | None | 079 | Fixing all type of Luminaries Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / Girders (p.no.56.it.no.13.7.1) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 128.1 | 128.1 | 4.0 | False | None | None | False | None | False | 512.4 | 0 |
3827200 | 145775 | None | 080 | Fixing of LED Lights Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps.(p.no.58.it.no.13.19) (PWD CSR for Electrical Works for the Year 2023-24) | Each | 514.5 | 514.5 | 2.0 | False | None | None | False | None | False | 1029.0 | 0 |
3827201 | 145775 | None | 081 | Supplyingexhaustfanof1440RPMof300mm(12")sizewithbracketbladescompleteforlightdutysuitabletooperateon230V50Hz, AC Supply. (PWD CSR for Electrical Works for the Year 2023-24 P.no.30.it.no.6.1) | Each | 1492.0 | 1492.0 | 1.0 | False | None | None | False | None | False | 1492.0 | 0 |
3827202 | 145775 | None | 082 | Supplying,fixingandwiringElectronicTrivectorMeter(ETV)5to32/63Athreephase4wirewholecurrentclass-1AccuracyEnergyMeter. (PWD CSR for Electrical Works for the Year 2023-24 P.no.30.it.no.5.35) | Each | 5705.0 | 5705.0 | 1.0 | False | None | None | False | None | False | 5705.0 | 0 |
3827203 | 145775 | None | 083 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (All other type of structures).PWD DSR 2023-24 Volume-I Page No. 18, Item No. 2.11h | Tonne | 82961.55 | 82961.55 | 0.494 | False | None | None | False | None | False | 40983.0057 | 0 |
3827204 | 145775 | None | 084 | Fabrication,Supplying,Erection,TestingandCommissioningof.mslongPolygonhighmastwithSingle/Multipletelescopicsectionshaving,(minimumoverlapdistanceof1.5timesoftopsection)thicknessasperBSEN10025grades355JO/ASTMA57250steelsheetplateforshaftsuitabletowithstandawindvelocityof47m/sasperIS875part3(asperGADrawing).BaseplateasperIS2062/ASTMA57250.ThemastshallbeGalvanizedinsingleHotdipasperBSENISO1461/ASTMA123withanaverage70micronsasperIS2629,andweldedasperBS5135SingleLSeamjointThemastshallhave2WayheadframewithdiecastLM6pulleys,stainlesssteelaxle,PhosphorusBronzebearingbushpressfittedwithseparateguidesfor2runsof5mmdia,stainlesssteelwireropeofAISI304grade7/19core,(FactorofSafetyasperTRno7).2.5mm2EPRinsulatedPCPsheathedtrailingpowercablehousedinsidethebottomshaftofmastwithdoorhavinglockingarrangementThemastshallhavemanual/powertool(Suitablereversiblegearedmotoroperatingon230/415V,50Hz,shallbeprovideabove15Mtrmast)Themastshallhavelanternof2segments,suitablediawithmaxloadcarryingcapacityasperIS1239.ThemastshallbeerectedonexistingRCCfooting.Themastshallbesuppliedwith3mmthicktemplate,lightningarresterof1.2mlengthgalvanizedpipewithtoparrowfittedontopoftheheadframecoverandGLStypeaviationtwinlAfittingwithwiringcomplete.(excludingfoundation)asper technical data.12 m/12.5 m - Top 100 mm and Bottom 310 mm dia (PWD ELE SR 2023-24 Volume-VI Page No. 13 OF 105, Item No. 4.5.1 | Each | 137550.0 | 137550.0 | 2.0 | False | None | None | False | None | False | 275100.0 | 0 |
3827205 | 145775 | None | 085 | SupplyofLEDfloodlightluminairewithpressurediecastaluminiumhousingbodyforoptimalthermaldissipation.LampcompartmentcomprisingofantiglarecleardiffuserwithInjectionmouldedpolycarbonate/clearglassmaterial,deliveringsuperiorlightoutputRatedlifeBurningHrs50000hr@LumenMaintenanceof70,CCT5500K,IP66opticalandelectricalcompartment&impactresistanceofcompleteluminaireIK08.PowerFactor0.9withmains,SurgeProtectionMin5KValongwithOvervoltage/Overload,shortcircuit/misswiringprotection.Compatibleforpolemaulingwithouterdiaof40mmto50mm.UniversalVoltagedrivertooperatewidevoltagerangefrom100Vto270V50/60Hzapplication.CompliancetoIS10322/IEC60598,LM79&LM80AdherencewithRoHS.ULapprovedMCPCB.Topaccessstreetlightwithsinglescrewtoensureeaseofmaintenanceatthesightsitelocationwithminimizedminimaltools.LEDLightfixturewith.WSystemPowerconsumption.LEDEfficiency1301m/w,nominalCRI75.LuminairemanufacturershouldhaveinhousefacilityaccreditedbyNABLCPRI&anyGovernmentcertifiedagency&Design&DevelopmentfacilitycertifiedbyISO9001:2008.Housingwithsupplierwordmark/nameshallbeEngravedEmbossingonthediecasthousing/BodypartWarrantyof2YearsagainstanymanufacturingdefectworkingunderstandardelectricalconditionsasmentionedaboveshouldbegivenbyLEDmanufacturer&Cree/Nichia/Lumileds/Osrammake LED Source.LED Floodlight 200W(PWD ELE SR 2023-24 Volume-VI Page No. 46 OF 105, Item No. 11.9.6 | Each | 19510.05 | 19510.05 | 16.0 | False | None | None | False | None | False | 312160.8 | 0 |
3827206 | 145775 | None | 086 | Fixinghalogen/metalhalide/SVL/IL/LEDfloodlightfittingoverexistingpole/wallceilingincludingclamps,bolts,nutsandwiringusing suitable capacity wires.(PWD ELE SR 2023-24 Volume-VI Page No. 46 OF 105, Item No. 13.5 | Each | 170.0 | 170.0 | 16.0 | False | None | None | False | None | False | 2720.0 | 0 |
3827207 | 145775 | None | 087 | Providing and fixing suitable for 1.1 KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps,bolts,nuts and washers etc. with necessary materials and labour tools and equipments as per instructions of engineer incharge of work.3.5x6 Sqm(PWD SR 2023-24 Volume-V Page No. 46 OF 105, Item No. 13.38.1) | Mtr | 393.75 | 393.75 | 60.0 | False | None | None | False | None | False | 23625.0 | 0 |
3827208 | 145775 | None | 088 | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0HDPE Grade PE80-PN6.0, 63mm dia(PWD SR 2023-24 Volume-V Page No.95 , Item No. 9.1.1) | Rmtr | 198.45 | 198.45 | 80.0 | False | None | None | False | None | False | 15876.0 | 0 |
3827209 | 145775 | None | 089 | SupplyinganddrawingFlexibleMulticoreCablemanufacturedwithelectrolyticgradeflexiblecopperwithlowconductorconfirmingtoIS81301984and(Virgin)PVCinsulationsheathedsuitableforworking voltage upto 1100 Volts as per IS-694:1990,3C x 2.5 mm2(PWD ELE SR 2023-24 Volume-VI Page No. 46 OF 105, Item No. 2.5.8 | Mtr | 118.65 | 118.65 | 60.0 | False | None | None | False | None | False | 7119.0 | 0 |
3827210 | 145775 | None | 090 | SupplyingandfixingMicroprocessorbasedElectronictimer(withoutcontactor,DinMountingusingnecessarybolts,nutsandwashersetc.,.)3-120sec setting.(PWD ELE SR 2023-24 Volume-VI Page No. 46 OF 105, Item No. 5.47) | Each | 2430.75 | 2430.75 | 2.0 | False | None | None | False | None | False | 4861.5 | 0 |
3827211 | 145775 | None | 091 | Earthing: Providing and fixing and wiring earth electrode for grounding
circuits IC cutouts and other equipments on the meter board in the pit.
The pits should be filled up with equal proportion of salt and charcoal
150mm around the pipe to complete depth. The connection from the
pipe to the conduits etc. is to established through GI wire of sizes as per
clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts,
the pipe shall have 16 through holes of 12mm dia.(PWD SR 2023-24 Volume-V Page No.157 , Item No. 13.39) | Job | 3937.5 | 3937.5 | 2.0 | False | None | None | False | None | False | 7875.0 | 0 |
3827212 | 145775 | None | 092 | FabricatingsupplyingandmountingMSboxmadeout.SWGsuitableforfloor/wallmounting,fullyweatherproofwithprovisionforbetterheatdissipation,providedwithhingedfrontcover,equippedwithtamperprooflockingarrangements,withsuitablesizeclampswithnecessarycableentrypipewithglandandboxshouldbefinishedwith7tankstreatmentwithpowdercoatedpaintand finally finished with approved colour etc., complete.14 SWG(PWD ELE SR 2023-24 Volume-VI Page No. 46 OF 105, Item No. 5.42.1) | Each | 0.53 | 0.53 | 4000.0 | False | None | None | False | None | False | 2120.0 | 0 |
3827213 | 145775 | None | 093 | SupplyingandfixingangleironframeworkfabricatedoutofM.S.angleiron.andM.S.Flat.withbolts,washersetc.,andpaintedwith 2 coats of red oxide and then two coats of approved paint.50 x 50 x 6 mm.(PWD ELE SR 2023-24 Volume-VI Page No. 20 OF 105, Item No. 5.41.2)
| Mtr | 414.75 | 414.75 | 60.0 | False | None | None | False | None | False | 24885.0 | 0 |
3827214 | 145775 | None | 094 | Supplying.Arated3phasewithneutralbusbarusingrequiredcapacityelectrolyticaluminiumstripscoveredwithheatshrinkablecolouredPVCsleeve,mountedonphenolic/FRP/DMCinsulatorwhicharemountedonpowdercoated40x6mmM.S.flatframeworkinexistingpanelboard.ThebusbarshallhavesuitableholesforterminationofincomingandoutgoingcablesasperISspecification with necessary bolts, nuts and washers etc., complete100 A 4 x 30 x 6 mm Aluminium Strips.(PWD ELE SR 2023-24 Volume-VI Page No. 20 OF 105, Item No. 5.40.1) | Mtr | 2588.25 | 2588.25 | 2.0 | False | None | None | False | None | False | 5176.5 | 0 |
3827215 | 145775 | None | 095 | SupplyingandfixingregularMCCBdistributionPanelconfirmingtoIS/IEC61439-3andIK09testedasperIS/IEC62262withminimumIP43protectionprovidedwithPolyurethane(PUR)gasket,withsuitableearthingsystem,onwall/woodboard/flushmountingusingrequiredclA,bolts,nuts,etc.,withprovisionforfixingofsuitabletypecapacityMCCB'sasanincomerfor3phaseDoubledoorwithnecessarybusbarcompletelywiredtouseon440V3phase4wirepowdercoatedpaintingetc.,completewithaprovisionforfixingofsingle/threephasesuitablecapacityMCB'sasoutgoingsconfirmingtoIS/IEC 60898 - 2.4 Way(PWD ELE SR 2023-24 Volume-VI Page No. 17 OF 105, Item No.5.17.1) | Each | 10845.45 | 10845.45 | 2.0 | False | None | None | False | None | False | 21690.9 | 0 |
3827216 | 145775 | None | 096 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947.95/100 A(PWD ELE SR 2023-24 Volume-VI Page No. 17 OF 105, Item No.5.17.1) | Each | 17436.3 | 17436.3 | 2.0 | False | None | None | False | None | False | 34872.6 | 0 |
3827217 | 145775 | None | 097 | Supplying & fixing of Porcelain fuse channel with cut out onexisting wooden/panel using necessary nuts, bolts and washers. 320 A Page No. 10 Item No.5.7.6 Electrical SR 2021-22
| Each | 1934.1 | 1934.1 | 2.0 | False | None | None | False | None | False | 3868.2 | 0 |
3827218 | 145775 | None | 098 | SupplyingofmultifunctiondigitalmeterwiththreelinebacklightLCDtypedisplayforvoltage,Current,frequency,Power,powerfactor,kVA,kWH,kVARsuitablefor3phase,4wireLTnetworkwithIP54degreeofprotectionandcompletelywiredasrequiredwithcommunication Port and Class 0.5s accuracy.(PWD ELE SR 2023-24 Volume-VI Page No. 17 OF 105, Item No.5.33) | Each | 9780.75 | 9780.75 | 2.0 | False | None | None | False | None | False | 19561.5 | 0 |
3827219 | 145775 | None | 099 | SupplyingandFixing.mmdiaclampsssAGIpipebracketupto2.7meterslongterminatedwithareducingcollarof40x25mmtowhichextrapipeof175mmlengthisfixedforfixingMV/SV/MH/FTLstreetlightfittingofallcapacitiesonrail/RCC/wall/tubularpole,usingsuitableclamps,bolts,nutsandwiringusingsuitablecapacitywires. Using 32mm dia G.I.Pipe(PWD ELE SR 2023-24 Volume-VI Page No. 17 OF 105, Item No.13.2.2) | No | 1359.75 | 1359.75 | 16.0 | False | None | None | False | None | False | 21756.0 | 0 |
3827220 | 145775 | None | 100 | GESCOM Deposit and Service Charegs for Power Connection | No | 15000.0 | 15000.0 | 1.0 | False | None | None | False | None | False | 15000.0 | 0 |
3827221 | 145775 | None | 101 | Providing half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in cement mortar 1:3 (1 Cement : 3 coarse sand) in superstructure for closing cavity 5 to 7.5 cm wide in cavity wall complete with 10cm / 11.4 cm wide bitumen felt type 3 grade 1 including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.PWD CSR 2023-24, Vol-II, P. No. 13, I. No. 6.29 | Sqm | 360.15 | 360.15 | 18.9 | False | None | None | False | None | False | 6806.835 | 0 |