1725088157000 | 0 | None | None | Buildings | Construction of First floor over ground floor in the premises of District Health and family welfare Office in Dharwad District. | 1592926.87 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3892405 | 149701 | None | 1.4.2 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. | Cum | 274.54 | 274.54 | 2.73 | False | None | None | False | None | False | 749.4942 | 0 | 3892406 | 149701 | None | 2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as pertechnical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Sqm | 6348.34 | 6348.34 | 0.27 | False | None | None | False | None | False | 1714.0518 | 0 | 3892407 | 149701 | None | 2.2.1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Footing | Cum | 7104.31 | 7104.31 | 0.82 | False | None | None | False | None | False | 5825.5342 | 0 | 3892408 | 149701 | None | 2.2.1 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Columns | Cum | 11002.25 | 11002.25 | 0.44 | False | None | None | False | None | False | 4840.99 | 0 | 3892409 | 149701 | None | 1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Sqm | 281.96 | 281.96 | 2.73 | False | None | None | False | None | False | 769.7508 | 0 | 3892410 | 149701 | None | 6.2 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete asper the direction of engineer incharge of work | Cum | 8456.68 | 8456.68 | 25.03 | False | None | None | False | None | False | 211670.7004 | 0 | 3892411 | 149701 | None | 2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6590.02 | 6590.02 | 1.03 | False | None | None | False | None | False | 6787.7206 | 0 | 3892412 | 149701 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Columns | Cum | 12043.68 | 12043.68 | 3.71 | False | None | None | False | None | False | 44682.0528 | 0 | 3892413 | 149701 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Lintel | Cum | 11359.38 | 11359.38 | 1.38 | False | None | None | False | None | False | 15675.9444 | 0 | 3892414 | 149701 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Staircase | Cum | 10675.08 | 10675.08 | 3.72 | False | None | None | False | None | False | 39711.2976 | 0 | 3892415 | 149701 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Roof Beam | Cum | 11359.38 | 11359.38 | 3.79 | False | None | None | False | None | False | 43052.0502 | 0 | 3892416 | 149701 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Slab | Cum | 10675.08 | 10675.08 | 13.43 | False | None | None | False | None | False | 143366.3244 | 0 | 3892417 | 149701 | None | 2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates StairCase | Cum | 10675.08 | 10675.08 | 3.76 | False | None | None | False | None | False | 40138.3008 | 0 | 3892418 | 149701 | None | 2.11 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | t | 94824.42 | 94824.42 | 3.0396 | False | None | None | False | None | False | 288228.307032 | 0 | 3892419 | 149701 | None | 11.34A | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding | Kg | 178.08 | 178.08 | 340.2 | False | None | None | False | None | False | 60582.816 | 0 | 3892420 | 149701 | None | 11.44A | Providing and fixing double glazed hermetically sealed glazing in aluminium windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminium spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 4605.7 | 4605.7 | 16.2 | False | None | None | False | None | False | 74612.34 | 0 | 3892421 | 149701 | None | 12.12 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications | Cum | 131654.12 | 131654.12 | 0.41 | False | None | None | False | None | False | 53978.1892 | 0 | 3892422 | 149701 | None | 12.18 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) | Sqm | 6970.56 | 6970.56 | 10.08 | False | None | None | False | None | False | 70263.2448 | 0 | 3892423 | 149701 | None | 9.12.5 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x1200 mm | Sqm | 1392.84 | 1392.84 | 84.52 | False | None | None | False | None | False | 117722.8368 | 0 | 3892424 | 149701 | None | 11.26.3 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Kg | 193.98 | 193.98 | 241.08 | False | None | None | False | None | False | 46764.6984 | 0 | 3892425 | 149701 | None | 8.4.1 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 342.38 | 342.38 | 260.87 | False | None | None | False | None | False | 89316.6706 | 0 | 3892426 | 149701 | None | 8.3.2 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 352.98 | 352.98 | 137.77 | False | None | None | False | None | False | 48630.0546 | 0 | 3892427 | 149701 | None | 8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 106.0 | 106.0 | 260.87 | False | None | None | False | None | False | 27652.22 | 0 | 3892428 | 149701 | None | 8.33.1 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Upto 3.50 m | Sqm | 167.48 | 167.48 | 260.87 | False | None | None | False | None | False | 43690.5076 | 0 | 3892429 | 149701 | None | 8.29 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 299.98 | 299.98 | 224.73 | False | None | None | False | None | False | 67414.5054 | 0 | 3892430 | 149701 | None | 1.2.1 | Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. | Mtr | 69.96 | 69.96 | 52.0 | False | None | None | False | None | False | 3637.92 | 0 | 3892431 | 149701 | None | 1.7.2 | Extra for groove cutting in brick wall/cc floor to the suitable depth for concealing of conduct/GI pipe and plastering finishing uo to wall surface complete uo to 50mm conduct cc floor. | Mtr | 73.14 | 73.14 | 52.0 | False | None | None | False | None | False | 3803.28 | 0 | 3892432 | 149701 | None | 2.1.1 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Short point upto 3Mtr from tapping point to out let via switch. | Point | 302.1 | 302.1 | 4.0 | False | None | None | False | None | False | 1208.4 | 0 | 3892433 | 149701 | None | 2.1.2 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch. | Each | 417.64 | 417.64 | 4.0 | False | None | None | False | None | False | 1670.56 | 0 | 3892434 | 149701 | None | 3.1.1 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6Amps 2 Way | Point | 135.68 | 135.68 | 4.0 | False | None | None | False | None | False | 542.72 | 0 | 3892435 | 149701 | None | 3.7 | Supplying and fixing 32Amps security and energy saving DP switch with key tag suitable to operate on 230 Volts, 50Hz AC supply & completely wired on existing box. | Each | 684.76 | 684.76 | 1.0 | False | None | None | False | None | False | 684.76 | 0 | 3892436 | 149701 | None | 1.6.1 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.12"x12"x3" (300 x 300 x 76 MM) | Each | 127.2 | 127.2 | 2.0 | False | None | None | False | None | False | 254.4 | 0 | 3892437 | 149701 | None | 2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. | Mtr | 27.56 | 27.56 | 40.0 | False | None | None | False | None | False | 1102.4 | 0 | 3892438 | 149701 | None | 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. | Mtr | 44.52 | 44.52 | 40.0 | False | None | None | False | None | False | 1780.8 | 0 | 3892439 | 149701 | None | 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. (4 sqmm ) | Mtr | 66.78 | 66.78 | 40.0 | False | None | None | False | None | False | 2671.2 | 0 | 3892440 | 149701 | None | 3.8 | Supplying 4mm thick Plastic sheet with necessary nitches for fixing switches, regulators etc., and fixing on existing wooden or metal box using N.F screws | Sq CM | 0.43 | 0.43 | 1000.0 | False | None | None | False | None | False | 430.0 | 0 | 3892441 | 149701 | None | 11.11.7 | Supplying and fixing of retrofit type LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K CRI 70. efficacy 80 lumen per watt, life 25000 burning hours and Compliance to IS 10322 IEC 60598, LM 79 LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5hould be between 130 to 275 volts. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition | Each | 451.56 | 451.56 | 6.0 | False | None | None | False | None | False | 2709.36 | 0 | 3892442 | 149701 | None | 6.3.2 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. | Each | 3212.86 | 3212.86 | 4.0 | False | None | None | False | None | False | 12851.44 | 0 | 3892443 | 149701 | None | 13.10 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. | Each | 181.26 | 181.26 | 4.0 | False | None | None | False | None | False | 725.04 | 0 | 3892444 | 149701 | None | 2.5.9 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS:8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100Volts as per IS-694:1990 4C X 2.5Sq.mm | Mtr | 156.88 | 156.88 | 25.0 | False | None | None | False | None | False | 3922.0 | 0 | 3892445 | 149701 | None | 13.47 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes 75 mm diameter | Mtr | 197.0 | 197.0 | 36.0 | False | None | None | False | None | False | 7092.0 | 0 |
|