3900577 | 150251 | None | code01 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (I No.1 12.1.1 P-No 139 of BWSSBSR 2023-24 Vol-5) A Upto 50 m depth | Mtr | 381.1 | 381.1 | 50.0 | False | None | None | False | None | False | 19055.0 | 0 |
3900578 | 150251 | None | code02 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) (I No.1 12.1.1 P-No 139 of BWSSBSR 2023-24 Vol-5) B. Above 50m depth and upto 100m | Mtr | 398.61 | 398.61 | 50.0 | False | None | None | False | None | False | 19930.5 | 0 |
3900579 | 150251 | None | code03 | Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty ( I No.12.32 P-No 143 of BWSSBSR 2023-24 Vol-5) | Mtr | 1990.99 | 1990.99 | 24.0 | False | None | None | False | None | False | 47783.76 | 0 |
3900580 | 150251 | None | code04 | M.S. Casing Collar 165 mm dia (S No 1949 P No 49 of BWSSB SR 2023-24) | Each | 154.5 | 154.5 | 1.0 | False | None | None | False | None | False | 154.5 | 0 |
3900581 | 150251 | None | code05 | Providing 175 mm dia M.S.Cap (S No 1950 P No 49 of BWSSB SR 2023-24) | Each | 168.96 | 168.96 | 1.0 | False | None | None | False | None | False | 168.96 | 0 |
3900582 | 150251 | None | code06 | Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. ( I No.12.40 P-No 140 of BWSSBSR 2023-24, Vol-5) | Each | 5446.64 | 5446.64 | 1.0 | False | None | None | False | None | False | 5446.64 | 0 |
3900583 | 150251 | None | code07 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034- 2000; 3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. 5.00 HP - 90 LPM @ 110 m = 15 STG Outlet Dia - 2.00" | Each | 40086.57 | 40086.57 | 1.0 | False | None | None | False | None | False | 40086.57 | 0 |
3900584 | 150251 | None | code08 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x2.5 m2 | Rmtr | 87.55 | 87.55 | 90.0 | False | None | None | False | None | False | 7879.5 | 0 |
3900585 | 150251 | None | code09 | Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mm | Each | 1287.5 | 1287.5 | 1.0 | False | None | None | False | None | False | 1287.5 | 0 |
3900586 | 150251 | None | code10 | Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mm | Each | 1287.5 | 1287.5 | 1.0 | False | None | None | False | None | False | 1287.5 | 0 |
3900587 | 150251 | None | code11 | Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts andthreads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For Heavy Duty GI pipe: 50mm dia GI pipes | Rmtr | 699.37 | 699.37 | 58.0 | False | None | None | False | None | False | 40563.46 | 0 |
3900588 | 150251 | None | code12 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOLDirect Online Starter 2) S-D- Star Delta Starter For OUTDOOR type Upto 6 HP pumps | Each | 18025.0 | 18025.0 | 1.0 | False | None | None | False | None | False | 18025.0 | 0 |
3900589 | 150251 | None | code13 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. | Job | 6695.0 | 6695.0 | 1.0 | False | None | None | False | None | False | 6695.0 | 0 |
3900590 | 150251 | None | code14 | Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work. | Job | 1390.5 | 1390.5 | 1.0 | False | None | None | False | None | False | 1390.5 | 0 |
3900591 | 150251 | None | code16 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.( I No.1.6 P.No.6 of Vol-1 2023-24) | Cum | 498.52 | 498.52 | 4.5 | False | None | None | False | None | False | 2243.34 | 0 |
3900592 | 150251 | None | code17 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. forPVC pipes 90mm dia., 6 kg/sqcm & class 3 ( CSR 2023-24 Vol:5 P.NO.113 I.No:10.1.6) | Mtr | 302.82 | 302.82 | 10.0 | False | None | None | False | None | False | 3028.2 | 0 |
3900593 | 150251 | None | code18 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications (CSR OF 2023-24, Volume -1, Page No. 07, Item No.1.10) | Cum | 210.12 | 210.12 | 10.0 | False | None | None | False | None | False | 2101.2 | 0 |
3900594 | 150251 | None | code19 | Supplying and wiring adopting loop systeem in existing PVC Conuit casing caping using copper PVC insulated multi strand 2 x 1.5 sqm copper wire with a 6 AMPS flush type SP control switch shall be fixed on the existing plastic sheet / gang box the other end of the wires shall be terminated with sufficient loose length in a wood / PVC round block, complete for each outle. (3/8) b) medium point above 3mtrs up to 6mtrs from tapping point to out let via switch ( CSR 2023-24 Vol:6 P.NO.5 I.No:2.1.2) | Each | 394.0 | 394.0 | 2.0 | False | None | None | False | None | False | 788.0 | 0 |
3900595 | 150251 | None | code20 | Wiring for lighting / power circuit using one of PVC insulated 1100 V grade multistrand copper conductor single vore cale in open or concealed system of wiring (9/20) I Group A c.2.5 sqmm (CSR 2023-24 Vol:6 P.NO.5 I.No:2.3) | Mtr | 42.0 | 42.0 | 50.0 | False | None | None | False | None | False | 2100.0 | 0 |
3900596 | 150251 | None | code21 | Wiring for lighting / power circuit using one of PVC insulated 1100 V grade multistrand copper conductor single vore cale in open or concealed system of wiring .(9/20) I Group d.4 sqmm ( CSR 2023-24 Vol:6 P.NO.5 I.No:2.3) | Mtr | 63.0 | 63.0 | 50.0 | False | None | None | False | None | False | 3150.0 | 0 |
3900597 | 150251 | None | code22 | Supplying PVC/Gi flexible conduct pipe mm dia fixing on surface over inverted tampered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and the either ends of the pipe terminated completely.(10/25) b) 25mm | Mtr | 48.41 | 48.41 | 10.0 | False | None | None | False | None | False | 484.1 | 0 |
3900598 | 150251 | None | code23 | Supplying and fixing a drop light using one PBBC/bakelite pendent holder, PVC insulated twin twisted copper wire of 23/0.0076” upto 1mtrs one of 60/100 watts lamp of 230 volts grade and of bakelit ceiling rose fixed on the existing wooden block of the outlet.(13/1) Group ‘A’ | Each | 90.64 | 90.64 | 1.0 | False | None | None | False | None | False | 90.64 | 0 |
3900599 | 150251 | None | code24 | Supplying decorative horizontal type street light fluoresecent fitting weather and water proof complete with energy saving electronic ballast etc locking type brass contact holders with 1 no of 4 feet 40watts fluorescent tube completely wired for use on 230/250 volts 50 cycles AC supply with opal reeded Perspex cover at bottom complete fitting.(17/6) 1.2x4’36/40 watts A Group ‘A’ | Each | 1921.98 | 1921.98 | 1.0 | False | None | None | False | None | False | 1921.98 | 0 |
3900600 | 150251 | None | code25 | Supplying and fixing of ….mm dia class A GI pipe bracket up to 2 mtrs long bent at suitable angle and fixing to this bracket 1x40/2x40 watts fluorescent tube street light fitting of all capacities to GI or rail or RCC pole/ wall using suitable clamps, bolts and nuts and wring using suitable capacity wires complete.(28/1) a) using 25mm dia GI pipe | Each | 919.79 | 919.79 | 1.0 | False | None | None | False | None | False | 919.79 | 0 |
3900601 | 150251 | None | code26 | Fixing charges of post top/Gate/Garden fitting on the existing CL/GI any other pipe using required size of reducer wiring using suitable wires etc., complete.(28/6) | Each | 276.04 | 276.04 | 1.0 | False | None | None | False | None | False | 276.04 | 0 |
3900602 | 150251 | None | code27 | Fixing halogen/metal halide/SVL/IL floodlight fitting over existing pole / wall ceiling including clamps bolts nuts and wiring using suitable capacity wires complete.(28/5) | Each | 123.6 | 123.6 | 1.0 | False | None | None | False | None | False | 123.6 | 0 |
3900603 | 150251 | None | code28 | Supplying of TPST with rewirable porcelain chanels in SM enclosure.(32/1) 32Amps Group’A’ | Each | 1493.5 | 1493.5 | 1.0 | False | None | None | False | None | False | 1493.5 | 0 |
3900604 | 150251 | None | code29 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using talered inverted wooden plugs screws etc.(32/2) a) 20”x20”x2.5” | Each | 311.06 | 311.06 | 2.0 | False | None | None | False | None | False | 622.12 | 0 |
3900605 | 150251 | None | code30 | Supplying & fixing of porcelain fuse channel with cut out on existing wooden/panel using necessary nuts bolts and washers etc., complete(32/3) 32 AMPS | Each | 185.4 | 185.4 | 6.0 | False | None | None | False | None | False | 1112.4 | 0 |
3900606 | 150251 | None | code31 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and ‘C’ type curve indicator ON/OFF, energy cross-3 with shoru circuit breaking capacity of 10K and complete wiring as required.(36/12) e) 5-32AMPS TPN Group ‘A’ | Each | 1994.08 | 1994.08 | 1.0 | False | None | None | False | None | False | 1994.08 | 0 |
3900607 | 150251 | None | code32 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C 50Hz 12/24v D.C(40/34) Group A | Each | 455.26 | 455.26 | 1.0 | False | None | None | False | None | False | 455.26 | 0 |
3900608 | 150251 | None | code33 | Supplying and fixing of DANGER/No ADMISSION/NO SMOKING board made out of MS sheet metal with two coats of non corrosive enameled paint(p-63,1-9) | Each | 61.8 | 61.8 | 1.0 | False | None | None | False | None | False | 61.8 | 0 |
3900609 | 150251 | None | code34 | Supplying fixing and wireing earth electrode for grounding conduits IC cutouts and other equipments on the metal board using 40mm dia, 2.90 mm thick GI pipe 2.5 Mtr. Long burried in a pit. The pit should be filled with equal proportion of salt and charcoal 150mm alround the pipe to complete depth. The connection form the pipe to the conduith etc., is to be establisahed through GI wire of size as per ISI specification. 7.3.3 of IS 732 using 12mm dia bolts nuts washers and checknuts etc, the pipe shall have 16 through holes of 122 mm dia.(68/1) | No | 2808.81 | 2808.81 | 2.0 | False | None | None | False | None | False | 5617.62 | 0 |
3900610 | 150251 | None | code35 | Supplying of LT UG cable having aluminium conductor PVC insulated, sheathed, galvanized steel wire/ steel tap armoured cable with PVC outer sheating 1.1 KV class.(68/4) 4 Core 10 sqmm | Mtr | 139.05 | 139.05 | 25.0 | False | None | None | False | None | False | 3476.25 | 0 |
3900611 | 150251 | None | code36 | Labour charges for laying of 1.1 KV class UG cable when supplied agency in existing trench GI pipe/ stoneware pipe/on wall/on pole as required.(69/5) In exixting trench/duct. 6 sqmm to16sqmm | Mtr | 31.93 | 31.93 | 25.0 | False | None | None | False | None | False | 798.25 | 0 |
3900612 | 150251 | None | code37 | Digging of trench of 0.6m deep x 0.50 mtrs wide refilling the trench to the required ground level and consolidating etc. complete.(As per civil SR KSRB I-2,P-7)(70/6) In soil(hard) | Mtr | 109.18 | 109.18 | 20.0 | False | None | None | False | None | False | 2183.6 | 0 |
3900613 | 150251 | None | code38 | Supplying and fixing of class A (medium duty) GI pipe of wall thick ness not less than 3.25mm on pole/ wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV class.(70/9) 40mm | Mtr | 355.35 | 355.35 | 6.0 | False | None | None | False | None | False | 2132.1 | 0 |
3900614 | 150251 | None | code39 | Supplying and fixing L.T cast lron pot heads suitable for 1.1 KV class UG cable filled with necessary bitumen/ insulating compound complete with terminals clamps bolts nuts and washers etc.(70/10) 10 sqmm | Each | 276.04 | 276.04 | 1.0 | False | None | None | False | None | False | 276.04 | 0 |
3900615 | 150251 | None | code40 | Supplying heavy gauge PVC conduit pipe dia confirming to IS 2509 with suitable size bends junction boxes adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.(2/1) b) 25mm dia 2mm thick | Per Mtr | 72.1 | 72.1 | 30.0 | False | None | None | False | None | False | 2163.0 | 0 |
3900616 | 150251 | None | 1.14.1 | Earth work excavation for Foundation by mechanical means for all works &depth upto 3 m, as per drawing and technical specifications, including settingout, shoring, strutting, barricading, caution lights, including dressing ofexcavated surfaces, disposing off or levelling the excavated earth or sorting& stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5m including cost of labour, tools, usage of machinery & other appurtenacesrequired to complete the work (CSR OF 2023-24, Pg-8, I-1.14.1 | Cum | 105.06 | 105.06 | 1.35 | False | None | None | False | None | False | 141.831 | 0 |
3900617 | 150251 | None | 3.1 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work (PWD SR 2023-24 Vol:3 P.NO.17 I.No:3.1) | Cum | 87.55 | 87.55 | 1.35 | False | None | None | False | None | False | 118.1925 | 0 |
3900618 | 150251 | None | 3.10 | Providing rubble and sand filling in layers of 250 to 300 mm including cost of all materials,machinery, labour, watering, ramming and all other ancillary operations complete.(CSR vol-4 OF 2023-24, Pg-48, I-3.10) | Cum | 2163.0 | 2163.0 | 0.45 | False | None | None | False | None | False | 973.35 | 0 |
3900619 | 150251 | None | 2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. (CSR vol-1 OF 2023-24, Pg-15, I-2.1.3) | Cum | 6168.67 | 6168.67 | 0.7 | False | None | None | False | None | False | 4318.069 | 0 |
3900620 | 150251 | None | 5.4 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (Common SR 2023-24 (Volume -2) 2022 Item No.5.4, Page No. 9) | Cum | 6580.67 | 6580.67 | 1.24 | False | None | None | False | None | False | 8160.0308 | 0 |
3900621 | 150251 | None | 5.2 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Providing Size Stone masonry with hard stone in foundation & plinth with Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)) (Common SR (Volume -2) 2022 Item No.5.2, Page No. 9) | Cum | 6816.54 | 6816.54 | 1.01 | False | None | None | False | None | False | 6884.7054 | 0 |
3900622 | 150251 | None | 2.4.2 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (CSR VOL-1 OF 2023-24, Pg-16, I-2.4.2) | Cum | 7512.92 | 7512.92 | 0.7 | False | None | None | False | None | False | 5259.044 | 0 |
3900623 | 150251 | None | 10.6 | RCC hume pipe Circular pump house: Providing precast RCC Circular Hume pipe pump house with M.S door and RCC conical roof as per specification and drawings - Internal dia Mtr. 1200 mm & height of 2.5 Mtr. With Wall thickness 65mm etc. complete.(CSR OF 2023-24, Vol-5, Pg- 116, I-10,6) | No | 16893.03 | 16893.03 | 1.0 | False | None | None | False | None | False | 16893.03 | 0 |
3900624 | 150251 | None | 6.5 | Providing Brick work with common burnt clay machine moulded perforated bricks of class designation 5.0 conforming to IS: 2222 in superstructure above plinth level in cement mortar 1:6 (1 cement : 6 coarse sand) With Non modular bricks including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (Common SR (Volume -2)-2023-24 Item No.6.5, Page No. 13) | Cum | 11306.31 | 11306.31 | 0.18 | False | None | None | False | None | False | 2035.1358 | 0 |
3900625 | 150251 | None | 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Common SR (Volume -2)-2023-24 Item No.8.2.1 Page No. 41) | Sqm | 303.85 | 303.85 | 14.04 | False | None | None | False | None | False | 4266.054 | 0 |
3900626 | 150251 | None | 8.24 | Distempering with dry distemper of approved brand and manufacture (two coats) of required shade on new work, over and including water thinnable priming coat to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (Common SR (Volume -2)-2023-24 Item No.8.24 Page No. 45) | Sqm | 111.24 | 111.24 | 14.04 | False | None | None | False | None | False | 1561.8096 | 0 |
3900627 | 150251 | None | 10.7 | Erection and positioning of RCC Hume pipe pump house/Cistern on size stone masory platform including transportation charges and handling,finishing with all necessary tools ,plants and materials etc.,complete as directed by the Engineer in charge (Common SR (Volume -5)-2023-24 Item No.10,7 Page No. 116) | No | 1938.46 | 1938.46 | 1.0 | False | None | None | False | None | False | 1938.46 | 0 |
3900628 | 150251 | None | 11.1.2 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete (Common SR (Volume -5)-2023-24 Item No.11,2,1 Page No. 127) | No | 215.27 | 215.27 | 12.0 | False | None | None | False | None | False | 2583.24 | 0 |
3900629 | 150251 | None | 11.2.6 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete (Common SR (Volume -5)-2023-24 Item No.11,2,6 Page No. 127) | No | 601.52 | 601.52 | 12.0 | False | None | None | False | None | False | 7218.24 | 0 |
3900630 | 150251 | None | 11.6.1 | Providing wrought mild steel (galvanized) GI collar confirming to IS 1239-II, 1991 with latest amendments if any.(Common SR (Volume -5)-2023-24 Item No.11,6,1 Page No. 129) | Kg | 60.77 | 60.77 | 4.0 | False | None | None | False | None | False | 243.08 | 0 |