1725325547000 | 0 | None | None | Other Works | Construction of water sump and fixing motor pump at Water treatment plant in T Narasipura TMC Limit | 346907.71 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3905168 | 150546 | None | code01 | Earth work excavation by manual means for drains,canals, waste weir draft,approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth (CSR OF 2023-24,Vol-1 Pg-6, I-1.5.1) | Cum | 307.97 | 307.97 | 18.0 | False | None | None | False | None | False | 5543.46 | 0 | 3905169 | 150546 | None | code02 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (CSR OF 2023-24,Vol-1 Pg-15, I-2.1.2) | Cum | 5833.92 | 5833.92 | 18.0 | False | None | None | False | None | False | 105010.56 | 0 | 3905170 | 150546 | None | code03 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(CSR OF 2023-24,Vol-1 Pg-16, I-2.4.2) | Cum | 6512.69 | 6512.69 | 18.0 | False | None | None | False | None | False | 117228.42 | 0 | 3905171 | 150546 | None | code04 | Providing Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour and usage charges of machinery complete as per the
direction of engineer incharge of work.(CSR OF 2023-24,Vol-1 Pg-105, I-3.9) | Cum | 4797.74 | 4797.74 | 6.9 | False | None | None | False | None | False | 33104.406 | 0 | 3905172 | 150546 | None | code05 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(CSR OF 2023-24,Vol-3 Pg-41, I-8.2.1) | Sqm | 303.85 | 303.85 | 24.0 | False | None | None | False | None | False | 7292.4 | 0 | 3905173 | 150546 | None | code06 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(CSR OF 2023-24,Vol-1 Pg-16, I-2.4.2) | Cum | 6512.69 | 6512.69 | 1.08 | False | None | None | False | None | False | 7033.7052 | 0 | 3905174 | 150546 | None | code07 | Solid Round glass fibre Reinforced Polymer (gfRP) Bars for Concrete Reinforcement IS 18256: 2023 Supplying, fitting & placing GFRP (Glass fibre Reinforced Polymer) bars conforming to IRC 137:2022 for structures such as Crash Barriers, Concrete drains, Concrete pavements, Approach slabs as per drawing & technical specification. (Only GFRP Bars manufactured using Vinyl Ester Resin systems and Glass fibres classified as E-CR or R that meet the requirements of ASTM D578 shall be used.(CSR OF 2023-24,Vol-3 Pg-87, I-9.3) | Kg | 213.21 | 213.21 | 44.65 | False | None | None | False | None | False | 9519.8265 | 0 | 3905175 | 150546 | None | code08 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5 .(CSR OF 2023-24,Vol-2 Pg-126, I-13.53) | No | 5811.26 | 5811.26 | 2.0 | False | None | None | False | None | False | 11622.52 | 0 | 3905176 | 150546 | None | code09 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. 2 HP, Size 65x50 Head 13M, Discharge 462 LPM .(CSR OF 2023-24,Vol-2 Pg-157, I-13.40.1) | Each | 16078.3 | 16078.3 | 2.0 | False | None | None | False | None | False | 32156.6 | 0 | 3905177 | 150546 | None | code10 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: DOL- Direct Online Starter Upto 3 HP pumps (CSR OF 2023-24,VOl-5 Pg-154 & 155, Item-13.23.) | No | 6695.0 | 6695.0 | 2.0 | False | None | None | False | None | False | 13390.0 | 0 | 3905178 | 150546 | None | code11 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. 1x3x1.5 Sqm. (CSR OF 2023-24,VOl-5 Pg-154, Item-13.22.1) | Each | 66.95 | 66.95 | 60.0 | False | None | None | False | None | False | 4017.0 | 0 | 3905179 | 150546 | None | code12 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specifications (CSR OF 2023-24,Vol-1 Pg-7, I-1.10) | Cum | 164.8 | 164.8 | 6.0 | False | None | None | False | None | False | 988.8 | 0 |
|