1725265182000 | 0 | None | None | Buildings | Construction of Anganawadi Center at virupapur Tanda Wno 34 in Gangavathi City limit | 1680353.87 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3901942 | 150347 | None | code01 | Earth work excavation by manual means for drains,canals and similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work Depth exceeding 1.5m, but not exceeding 3 m | Cum | 271.95 | 271.95 | 49.91 | False | None | None | False | None | False | 13573.0245 | 0 | 3901943 | 150347 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries,curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm and down size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 10.21 | False | None | None | False | None | False | 60720.912 | 0 | 3901944 | 150347 | None | code03 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD CSR 2023-24, Vol-I, P. No. 16, I. No. 2.4.2 | Cum | 9800.65 | 9800.65 | 13.137 | False | None | None | False | None | False | 128751.13905 | 0 | 3901945 | 150347 | None | code04 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates PWD CSR 2023-24, Vol-I, P. No. 16, I. No. 2.5.1 | Cum | 10939.5 | 10939.5 | 14.524 | False | None | None | False | None | False | 158885.298 | 0 | 3901946 | 150347 | None | code05 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specification | Tonne | 93929.85 | 93929.85 | 2.489 | False | None | None | False | None | False | 233791.39665 | 0 | 3901947 | 150347 | None | code06 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6708.45 | 6708.45 | 41.816 | False | None | None | False | None | False | 280520.5452 | 0 | 3901948 | 150347 | None | code07 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 62.333 | False | None | None | False | None | False | 17409.6069 | 0 | 3901949 | 150347 | None | code08 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of
engineer incharge of work. | Cum | 8367.45 | 8367.45 | 26.1682 | False | None | None | False | None | False | 218961.10509 | 0 | 3901950 | 150347 | None | code09 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Cum | 384.3 | 384.3 | 374.0544 | False | None | None | False | None | False | 143749.10592 | 0 | 3901951 | 150347 | None | code10 | Providing and laying Polished Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). | Cum | 1392.3 | 1392.3 | 51.9443 | False | None | None | False | None | False | 72322.04889 | 0 | 3901952 | 150347 | None | code11 | Providing Jungle wood such as Nerale, Neem wrought and putup for purlins, common rafters and similar work including cost of materials, labour, usage charges complete as per specifications. | Cum | 47175.45 | 47175.45 | 0.634 | False | None | None | False | None | False | 29909.2353 | 0 | 3901953 | 150347 | None | code12 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) | Sqm | 6029.1 | 6029.1 | 16.77 | False | None | None | False | None | False | 101108.007 | 0 | 3901954 | 150347 | None | code13 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Cum | 93.45 | 93.45 | 374.0544 | False | None | None | False | None | False | 34955.38368 | 0 | 3901955 | 150347 | None | code14 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Cum | 143.85 | 143.85 | 374.0544 | False | None | None | False | None | False | 53807.72544 | 0 | 3901956 | 150347 | None | code15 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Cum | 175.35 | 175.35 | 33.54 | False | None | None | False | None | False | 5881.239 | 0 | 3901957 | 150347 | None | code16 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS hinges 100 mm | Each | 73.5 | 73.5 | 30.0 | False | None | None | False | None | False | 2205.0 | 0 | 3901958 | 150347 | None | code17 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Tower Bolts 150x10mm | Each | 126.0 | 126.0 | 30.0 | False | None | None | False | None | False | 3780.0 | 0 | 3901959 | 150347 | None | code18 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Aldrop 16mm dia, 300mm | Each | 393.75 | 393.75 | 6.0 | False | None | None | False | None | False | 2362.5 | 0 | 3901960 | 150347 | None | code19 | Providing and fixing M.S. grills of required pattern in frames of windows etc with M,S.flats,square or round bars etc.including priming coat wiyh approved steel primer allcomplete . Fixed to openings/ wooden frames with rawl plugs screws etc | Kg | 192.15 | 192.15 | 307.125 | False | None | None | False | None | False | 59014.06875 | 0 | 3901961 | 150347 | None | code20 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin- Charge. | Cum | 144.9 | 144.9 | 135.0 | False | None | None | False | None | False | 19561.5 | 0 | 3901962 | 150347 | None | code21 | Supplying heavy gauge PVC conduit pipe 20 mm dia 1.0 mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. | m | 66.0 | 66.0 | 30.0 | False | None | None | False | None | False | 1980.0 | 0 | 3901963 | 150347 | None | code22 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make180 x 90 x 65 mm etc.,(Elect. SR 2023-24/Page No. 1/Item No. 1.4.4) 180 x 90 x 65 mm | No | 161.0 | 161.0 | 2.0 | False | None | None | False | None | False | 322.0 | 0 | 3901964 | 150347 | None | code23 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100V as per IS- 694:2010 | m | 121.0 | 121.0 | 90.0 | False | None | None | False | None | False | 10890.0 | 0 | 3901965 | 150347 | None | code24 | Supplying and wiring adopting loop system in existing PVCConduit /casing capping using 2x1.5mm2 (Phase & Neutral)& 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existingplastic sheet/ gang box, the other end of the wires shall beterminated with sufficient loose length in a wood/PVC round block. complete for each outlet.) Medium point above 3m upto 6m from tapping point to out let via switch (Elect. SR 2023-24 Page No. 2/Item No. 2.1.2) | No | 394.0 | 394.0 | 2.0 | False | None | None | False | None | False | 788.0 | 0 | 3901966 | 150347 | None | code25 | Supplying and mounting 2 Nos of 2 way 6 amps flush type switches either surface/flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a lfusah mounted woodoen box and wiring as per IS 1293(Elect. SR 2023-24/Page No. 15/Item No. 3.2) | No | 170.0 | 170.0 | 10.0 | False | None | None | False | None | False | 1700.0 | 0 | 3901967 | 150347 | None | code26 | Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. 32A Bakelite DP (Elect. SR 2023-24/Page No. 15/Item No. 3.14.16) Electronic stepped regulator | No | 281.0 | 281.0 | 1.0 | False | None | None | False | None | False | 281.0 | 0 | 3901968 | 150347 | None | code27 | Supplying and fixing superior qualityh moudlar switch mounting polycar bonate plate with necessary supporting back plate with required nos of machine screws, bolts nuts etc., complete on the existing metal/PVC box 4 module. (Elect. SR 2023-24/Page No. 16/Item No. 3.5.8) | No | 457.0 | 457.0 | 2.0 | False | None | None | False | None | False | 914.0 | 0 | 3901969 | 150347 | None | code28 | Supplying & fixing retrofit type-PL- LED Lamp ...... W LED linear source with CCT 6500 degree K, CRI 70. efficacy 80 lumen per W, life25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to275 V. Tested
by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition (Elect. SR 2023-24/Page No. 34/Item No. 11.2.2) 18-20 W | No | 702.0 | 702.0 | 6.0 | False | None | None | False | None | False | 4212.0 | 0 | 3901970 | 150347 | None | code29 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve indictor ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40-63 Amps TPN(Elect. SR 2023-24/Page No.13/Item No. 5.17.8) | No | 2393.0 | 2393.0 | 1.0 | False | None | None | False | None | False | 2393.0 | 0 | 3901971 | 150347 | None | code30 | Supplying and fixing PVC/metal conduit accessories.(2/1.5) ( 25mm junction box) (Elect. SR 2023-24/Page No.1/Item No. 1.5.1) | No | 49.0 | 49.0 | 10.0 | False | None | None | False | None | False | 490.0 | 0 | 3901972 | 150347 | None | code31 | Supplying of Ceiling Fan with Capacitor rating As perguideline of BEE 5 star rating and IS:374/79 and alsocomply with IS:1709/1984 with latest amendment, Ratedvoltage 220 V/ 50 Hz, Rated power input 48 W +/- 10%,Rated current As per IS:374/79, Rated power factor 0.9lagging(min), Rated speed 350 +/- 10% RPM, Rated airdelivery 210 10% Cubic Meter Minimum, Rated servicevalue 4.2 CMM / Watt, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation,Bearing Two ball bearings, Top 6202, Bottom 6201 , as per ISspecification, Motor wdg. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245Volts, Insulation resistance Shall not be less than Two MegaOhms (2 M Ohms), Leakage current Should not exceed 210Micro Amp, Power input, watt& current , Air Delivery & FanSpeed as per IS:374/1979 with latest amendment, 2 yearmanufacturer Warranty. (Elect. SR 2023-24 Page No.23/Item No.6.4.2) 56" Sweep 5 Star (1400 mm) | No | 2900.0 | 2900.0 | 2.0 | False | None | None | False | None | False | 5800.0 | 0 | 3901973 | 150347 | None | code32 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy Electrical SR 2023-24/P.No.19/I.No 5.33 | No | 9315.0 | 9315.0 | 1.0 | False | None | None | False | None | False | 9315.0 | 0 |
|