1725262958000 | 1 | None | None | Buildings | Construction Of Shed for Material Recovery Facility In Turvihal Town Limits. | 3021231.3 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3901242 | 150297 | None | code01 | KSRB 1-1.14.1: Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Item No. 1.14.1 Page No. 8 Vol.1 PWD SR) | Cum | 123.97 | 123.97 | 29.407 | False | None | None | False | None | False | 3645.58579 | 0 | 3901243 | 150297 | None | code02 | KSRB 2-2.1.2: Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1, (Item No. 2.1.2 Page No. 15 Vol.1 PWD SR) | Cum | 7017.69 | 7017.69 | 28.9675 | False | None | None | False | None | False | 203284.935075 | 0 | 3901244 | 150297 | None | code03 | KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes ,labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) | Cum | 8258.11 | 8258.11 | 7.1199 | False | None | None | False | None | False | 58796.917389 | 0 | 3901245 | 150297 | None | code04 | KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes ,labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) | Cum | 12998.88 | 12998.88 | 1.63 | False | None | None | False | None | False | 21188.1744 | 0 | 3901246 | 150297 | None | code05 | KSRB 2-2.3.2:Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes ,labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) | Cum | 8258.11 | 8258.11 | 28.62 | False | None | None | False | None | False | 236347.1082 | 0 | 3901247 | 150297 | None | code06 | KSRB 2-2.2.3.1 :Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115) | Cum | 11588.54 | 11588.54 | 4.824 | False | None | None | False | None | False | 55903.11696 | 0 | 3901248 | 150297 | None | code07 | KSRB 2.11 Steel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.(Item No. 2.11 Page No. 18 Vol.1 PWD SR) | Kg | 110.84 | 110.84 | 2773.1 | False | None | None | False | None | False | 307370.404 | 0 | 3901249 | 150297 | None | code08 | KSRB 5-5.4: Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR) | Cum | 7915.97 | 7915.97 | 16.67 | False | None | None | False | None | False | 131959.2199 | 0 | 3901250 | 150297 | None | code09 | KSRB 1-1.8: Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,allmaterials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR) | Cum | 587.28 | 587.28 | 128.79 | False | None | None | False | None | False | 75635.7912 | 0 | 3901251 | 150297 | None | code10 | KSRB 6-6.33: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR) | Cum | 1525.2 | 1525.2 | 13.6619 | False | None | None | False | None | False | 20837.12988 | 0 | 3901252 | 150297 | None | code11 | KSRB 8-8.3.1: Providing 15mm/18mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.3.1, Page No. 41, Vol.2) | Sqm | 358.54 | 358.54 | 187.56 | False | None | None | False | None | False | 67247.7624 | 0 | 3901253 | 150297 | None | code12 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2) | Kgs | 140.0 | 140.0 | 6500.0 | False | None | None | False | None | False | 910000.0 | 0 | 3901254 | 150297 | None | code13 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2) | Sqm | 703.75 | 703.75 | 518.21 | False | None | None | False | None | False | 364690.2875 | 0 | 3901255 | 150297 | None | code14 | KSRB 8-8.51 : Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Item No. 8.51, Page No. 50, Vol.2) | Sqm | 123.9 | 123.9 | 187.56 | False | None | None | False | None | False | 23238.684 | 0 | 3901256 | 150297 | None | code15 | KSRB 8-8.54.1 : Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.(Item No. 8.54.1, Page No. 50, Vol.2) | Sqm | 90.44 | 90.44 | 187.56 | False | None | None | False | None | False | 16962.9264 | 0 | 3901257 | 150297 | None | code16 | KSRB 8-8.75.2 : Finishing walls with Premium Acrylic Smooth exterior paint of required shade : Old work (one coats applied @ 0.83 l/10 m²) including preparing the surface after thoroughly cleaning the surface to remove all dirt,dust and foreign matter , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.75.2, Page No. 53, Vol.2) | Sqm | 90.44 | 90.44 | 187.56 | False | None | None | False | None | False | 16962.9264 | 0 | 3901258 | 150297 | None | code17 | KSRB 11-11.6.1:Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2) | Sqm | 3262.28 | 3262.28 | 9.0 | False | None | None | False | None | False | 29360.52 | 0 | 3901259 | 150297 | None | code18 | KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 77, Vol.2) | Each | 30585.95 | 30585.95 | 1.0 | False | None | None | False | None | False | 30585.95 | 0 | 3901260 | 150297 | None | code19 | KSRB 11-11.35.1.1:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications..(Item No. 11.35.1.1, Page No. 87, Vol.2) | Kgs | 560.02 | 560.02 | 240.0 | False | None | None | False | None | False | 134404.8 | 0 | 3901261 | 150297 | None | code20 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Overload and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947-2. (Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short-Cicrcuit/OverLoad.For Microprocessor MCCB S Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. Three Pole- 100 A 25 kA (P.No.17, I.No.5.15.1 in CSR Electrical SR Volume-6 2023-24) | Each | 7396.92 | 7396.92 | 5.0 | False | None | None | False | None | False | 36984.6 | 0 | 3901262 | 150297 | None | code21 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws,bolts,nuts,necessary phase separators,handle and wiring complete.Protection of Overload and Short circuit with adjustable thermal magnetic release,Microprocessor release shall have Earth Fault as per IS/IEC60947-2. (Icu=100%lcs).In 4P MCCB,all Poles should have protection for Short-Cicrcuit/OverLoad.For Microprocessor MCCB S Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open).Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. Four Pole-100 A 25 kA (P.No.17, I.No.5.15.9 in CSR Electrical SR Volume-6 2023-24) | Each | 10315.09 | 10315.09 | 5.0 | False | None | None | False | None | False | 51575.45 | 0 | 3901263 | 150297 | None | code22 | Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA.16-32 A SP (P.No.21, I.No.5.46.1 in CSR Electrical SR Volume-6 2023-24) | Each | 255.23 | 255.23 | 6.0 | False | None | None | False | None | False | 1531.38 | 0 | 3901264 | 150297 | None | code23 | Supplying and fixing of Modular MCB Devices (Tripper) With Breaking capacity of 6kA. 63 A TP (P.No.21, I.No. 5.46.6 in CSR Electrical SR Volume-6 2023-24) | Each | 1452.4 | 1452.4 | 5.0 | False | None | None | False | None | False | 7262.0 | 0 | 3901265 | 150297 | None | code24 | Supplying.........A rated 3 phase with neutral busbar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve,mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board.The busbar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100 A 4 x 30 x 6 mm Aluminium Strips (P.No.20, I.No.5.40.1 in CSR Electrical SR Volume-6 2023-24) | Mtr | 2995.96 | 2995.96 | 12.0 | False | None | None | False | None | False | 35951.52 | 0 | 3901266 | 150297 | None | code25 | Supplying and fixing angle iron frame work fabricated out of M.S.angle iron..and M.S.Flat......with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint.(P.No.20, I.No.5.41.1 in CSR Electrical SR Volume-6 2023-24) | Mtr | 370.69 | 370.69 | 6.0 | False | None | None | False | None | False | 2224.14 | 0 | 3901267 | 150297 | None | code26 | Fabricating supplying and mounting MS box made out....SWG suitable for floor/wall mounting,fully weather proof with provision for better heat dissipation,provided with hinged front cover,equipped with tamper proof locking arrangements,with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7 tanks treatment with powder coated paint and finally finished with approved colour etc., complete.(P.No.20, I.No.5.42.1 in CSR Electrical SR Volume-6 2023-24) | Sqm | 0.6 | 0.6 | 35000.04 | False | None | None | False | None | False | 21000.024 | 0 | 3901268 | 150297 | None | code27 | Supply and fixing of 3pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts,nuts,washers and wiring etc., complete with AC-3 Rating and as per IS-13947.(P.No.15 , I.No.5.13.1 in CSR Electrical SR Volume-6 2023-24) | Each | 1567.86 | 1567.86 | 2.0 | False | None | None | False | None | False | 3135.72 | 0 | 3901269 | 150297 | None | code28 | Supplying and fixing Micro processor Based Astro nomical timer Switch with using necessary bolts, nuts and washers.(P.No.21, I.No.5.48 in CSR Electrical SR Volume-6 2023-24) | Each | 5886.18 | 5886.18 | 2.0 | False | None | None | False | None | False | 11772.36 | 0 | 3901270 | 150297 | None | code29 | Supply and fixing of Auxiliary contactor relay with 2 NO and 2 NC contact and operating coil voltage of 220V to 260V. fixed on existing wood/panel board using necessary bolts, nuts, washers and wiring etc.,(P.No.22, I.No.5.53 in CSR Electrical SR Volume-6 2023-24) | Each | 1616.48 | 1616.48 | 3.0 | False | None | None | False | None | False | 4849.44 | 0 | 3901271 | 150297 | None | code30 | Supplying and fixing of metal clad industrial plugs and sockets. (P.No.9, I.No.3.13.3 in CSR Electrical SR Volume-6 2023-24) 3pole+earth 440V PLUG-32 Amps
16 Amps (P.No.9, I.No.3.13.3 in CSR Electrical SR Volume-6 2023-24) | Each | 549.51 | 549.51 | 2.0 | False | None | None | False | None | False | 1099.02 | 0 | 3901272 | 150297 | None | code31 | Supplying and fixing of metal clad industrial plugs and sockets. (P.No.9, I.No.3.13.3 in CSR Electrical SR Volume-6 2023-24) 3pole+earth 440V PLUG-32 Amps
32 Amps (P.No.9, I.No.3.13.4 in CSR Electrical SR Volume-6 2023-24) | Each | 741.22 | 741.22 | 2.0 | False | None | None | False | None | False | 1482.44 | 0 | 3901273 | 150297 | None | code32 | Supplying,fixing and wiring 0to30 A Direct Reading AC analog type Ammeter.(P.No.18, I.No.5.24 in CSR Electrical SR Volume-6 2023-24) | Each | 565.16 | 565.16 | 4.0 | False | None | None | False | None | False | 2260.64 | 0 | 3901274 | 150297 | None | code33 | Supplying,fixing and wiring 0 to 600 V 96x96mm AC Voltmeter on existing panel/wood board.(P.No.18, I.No.5.22 in CSR Electrical SR Volume-6 2023-24) | Each | 549.36 | 549.36 | 1.0 | False | None | None | False | None | False | 549.36 | 0 | 3901275 | 150297 | None | code34 | Supplying,fixing and wiring rotary selector switch suitable for Ammeter.(P.No.19, I.No.5.27 in CSR Electrical SR Volume-6 2023-24) | Each | 243.07 | 243.07 | 4.0 | False | None | None | False | None | False | 972.28 | 0 | 3901276 | 150297 | None | code35 | Supplying, fixing and wiring rotary selector switch suitable for Voltmeter.(P.No.19, I.No.5.28 in CSR Electrical SR Volume-6 2023-24) | Each | 194.46 | 194.46 | 1.0 | False | None | None | False | None | False | 194.46 | 0 | 3901277 | 150297 | None | code36 | Supplying,fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.(P.No.19, I.No.5.34 in CSR Electrical SR Volume-6 2023-24) | Each | 683.05 | 683.05 | 4.0 | False | None | None | False | None | False | 2732.2 | 0 | 3901278 | 150297 | None | code37 | Supplying and fixing digital frequency meter with latest micro controller technology,ultra bright 4digit LED display,from 30-500VAC and optional or relay output for high/low frequency and wiringcomplete.(P.No.19, I.No.5.32 in CSR Electrical SR Volume-6 2023-24) | Each | 1185.01 | 1185.01 | 1.0 | False | None | None | False | None | False | 1185.01 | 0 | 3901279 | 150297 | None | code38 | Supplying,fixing and wiring heavy duty low voltage capacitors conforming to IS2834.3 phase,400/440V grade,for power factor improvement of rotating machineries like induction motor.(P.No.19, I.No.5.37 in CSR Electrical SR Volume-6 2023-24) | Kvar | 583.39 | 583.39 | 5.0 | False | None | None | False | None | False | 2916.95 | 0 | 3901280 | 150297 | None | code39 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.3.5Cx50 Sqmm Al Ar cable ESCOM SR 2023-24 I No. 32.11 Pg.13 | Km | 217523.78 | 217523.78 | 0.03 | False | None | None | False | None | False | 6525.7134 | 0 | 3901281 | 150297 | None | code40 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.4Cx25 Sqmm Al Ar cable.ESCOM SR 2023-24 I No. 32.08 Pg.13 | Km | 218582.39 | 218582.39 | 0.02 | False | None | None | False | None | False | 4371.6478 | 0 | 3901282 | 150297 | None | code41 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.4Cx16 Sqmm Al Ar cable ESCOM SR 2023-24 I No. 32.05 Pg.13 | Km | 172394.76 | 172394.76 | 0.02 | False | None | None | False | None | False | 3447.8952 | 0 | 3901283 | 150297 | None | code42 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975.4Cx10 Sqmm Cu Ar cable.ESCOM SR 2023-24 I No. 32.03 Pg.13 | Km | 143422.06 | 143422.06 | 0.02 | False | None | None | False | None | False | 2868.4412 | 0 | 3901284 | 150297 | None | code43 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT cable 2.5 to 25 sqmm ESCOM SR 2023-24 I No. 21.05 Pg.52 | Km | 25384.84 | 25384.84 | 0.06 | False | None | None | False | None | False | 1523.0904 | 0 | 3901285 | 150297 | None | code44 | 35 to 95 Sqmm .ESCOM SR 2023-24 I No. 21.06 Pg.52 | Km | 37846.34 | 37846.34 | 0.03 | False | None | None | False | None | False | 1135.3902 | 0 | 3901286 | 150297 | None | code45 | Earth Work Excavation for pipeline/cables by manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shorting, strutting,barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a redius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth sides of foundations etc.. in layers not exceeding 20 cm in depth, consolidated each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.(P.No.06, I.No 1.6.1 in KPWD CSR volume-1, 2023-24 In all kind of soils, Depth upto 1.50m | Cum | 588.25 | 588.25 | 6.75 | False | None | None | False | None | False | 3970.6875 | 0 | 3901287 | 150297 | None | code46 | Cable Joint and wiring (for HT & LT UG Cable). LT UG Cable. Heat shrinkable Type Terminations 2.5 to 25 Sqmm .ESCOM SR 2023-24 I No. 22.13 Pg.53 | Set | 114.24 | 114.24 | 12.0 | False | None | None | False | None | False | 1370.88 | 0 | 3901288 | 150297 | None | code47 | Cable Joint and wiring (for HT & LT UG Cable). LT UG Cable. Heat shrinkable Type Terminations 35 to 95 Sqmm .ESCOM SR 2023-24 I No. 22.14 Pg.53 | Set | 230.92 | 230.92 | 2.0 | False | None | None | False | None | False | 461.84 | 0 | 3901289 | 150297 | None | code48 | Supplying & Fixing heavy guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws. PWD Electrical SR-2023-24, ITEM NO:1.1 ,CH-1, PAGE NO-2
19/20mm dia PVC 2mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.1 ,CH-1, PAGE NO-2 | Mtr | 83.86 | 83.86 | 25.0 | False | None | None | False | None | False | 2096.5 | 0 | 3901290 | 150297 | None | code49 | 25mm dia PVC 2mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.2 ,CH-1, PAGE NO-2 | Mtr | 98.44 | 98.44 | 25.0 | False | None | None | False | None | False | 2461.0 | 0 | 3901291 | 150297 | None | code50 | 32mm dia PVC 2.5mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.3 ,CH-1, PAGE NO-2 | Mtr | 128.83 | 128.83 | 20.0 | False | None | None | False | None | False | 2576.6 | 0 | 3901292 | 150297 | None | code51 | 40mm dia PVC 2.5mm thick conduit.PWD Electrical SR-2023-24, ITEM NO:1.1.4 ,CH-1, PAGE NO-2 | Mtr | 181.09 | 181.09 | 20.0 | False | None | None | False | None | False | 3621.8 | 0 | 3901293 | 150297 | None | code52 | Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5 Sqmm (Phase&Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gangbox, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch. PWD Electrical SR-2023-24, ITEM NO:2.1.1 ,CH-1, PAGE NO-5 | Nos | 346.38 | 346.38 | 10.0 | False | None | None | False | None | False | 3463.8 | 0 | 3901294 | 150297 | None | code53 | Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch .PWD Electrical SR-2023-24, ITEM NO:2.1.2 ,CH-1, PAGE NO-5 | Nos | 478.86 | 478.86 | 10.0 | False | None | None | False | None | False | 4788.6 | 0 | 3901295 | 150297 | None | code54 | Long point above 6Mtr upto 10Mtr from tapping point to out let via switch.PWD Electrical SR-2023-24, ITEM NO:2.1.3 ,CH-1, PAGE NO-5 | Nos | 692.77 | 692.77 | 6.0 | False | None | None | False | None | False | 4156.62 | 0 | 3901296 | 150297 | None | code55 | Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to outlet via switches.PWD Electrical SR-2023-24, ITEM NO:2.1.4 ,CH-1, PAGE NO-5 | Nos | 860.5 | 860.5 | 5.0 | False | None | None | False | None | False | 4302.5 | 0 | 3901297 | 150297 | None | code56 | Three outlet in a row, above 6Mts upto 10Mtr from tapping point to out let via switches.PWD Electrical SR-2023-24, ITEM NO:2.1.5 ,CH-1, PAGE NO-5 | Nos | 1257.93 | 1257.93 | 2.0 | False | None | None | False | None | False | 2515.86 | 0 | 3901298 | 150297 | None | code57 | Wiring for lighting /power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010.1.0 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.1 ,CH-1, PAGE NO-5 | Mtr | 23.09 | 23.09 | 200.0 | False | None | None | False | None | False | 4618.0 | 0 | 3901299 | 150297 | None | code58 | 1.5 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.2 ,CH-1, PAGE NO-5 | Mtr | 31.6 | 31.6 | 80.0 | False | None | None | False | None | False | 2528.0 | 0 | 3901300 | 150297 | None | code59 | 2.5 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.3 ,CH-1, PAGE NO-5 | Mtr | 51.04 | 51.04 | 80.0 | False | None | None | False | None | False | 4083.2 | 0 | 3901301 | 150297 | None | code60 | 4.0 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.4 ,CH-1, PAGE NO-5 | Mtr | 76.57 | 76.57 | 40.0 | False | None | None | False | None | False | 3062.8 | 0 | 3901302 | 150297 | None | code61 | 6.0 Sqmm Cu FRLS wire.PWD Electrical SR-2023-24, ITEM NO:2.3.5 ,CH-1, PAGE NO-5 | Mtr | 111.81 | 111.81 | 30.0 | False | None | None | False | None | False | 3354.3 | 0 | 3901303 | 150297 | None | code62 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws, bolts nuts etc.,complete on the existing metal/PVC box. 10 - 12 Module Polycarbonate switch box plate.PWD Electrical SR-2023-24, ITEM NO:3.5.6 ,CH-3, PAGE NO-8 | Nos | 418.09 | 418.09 | 5.0 | False | None | None | False | None | False | 2090.45 | 0 | 3901304 | 150297 | None | code63 | 3 Module Polycarbonate switch box plate.PWD Electrical SR-2023-24, ITEM NO:3.5.2 ,CH-3, PAGE NO-5 | Nos | 195.67 | 195.67 | 4.0 | False | None | None | False | None | False | 782.68 | 0 | 3901305 | 150297 | None | code64 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cuttingin Brick/C.C wall, including necessary rawl plugs,Machine/NF screws etc., complete. 3 Way PWD Electrical SR-2023-24, ITEM NO:3.3.2 ,CH-3, PAGE NO-8 | Nos | 150.7 | 150.7 | 5.0 | False | None | None | False | None | False | 753.5 | 0 | 3901306 | 150297 | None | code65 | 10-12 Way PWD Electrical SR-2023-24, ITEM NO:3.3.6 ,CH-3, PAGE NO-8 | Nos | 317.21 | 317.21 | 5.0 | False | None | None | False | None | False | 1586.05 | 0 | 3901307 | 150297 | None | code66 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Switches & sockets outlets in Existing modular box. PWD Electrical SR-2023-24, ITEM NO:3.6 ,CH-3, PAGE NO-9 6A one way switch.PWD Electrical SR-2023-24, ITEM NO:3.6.1 ,CH-3, PAGE NO-9 | Nos | 123.97 | 123.97 | 4.0 | False | None | None | False | None | False | 495.88 | 0 | 3901308 | 150297 | None | code67 | 6A 3 way socket.PWD Electrical SR-2023-24, ITEM NO:3.6.3 ,CH-3, PAGE NO-9 | Nos | 207.83 | 207.83 | 4.0 | False | None | None | False | None | False | 831.32 | 0 | 3901309 | 150297 | None | code68 | 6/16A Universal socket.PWD Electrical SR-2023-24, ITEM NO:3.6.10 ,CH-3, PAGE NO-9 | Nos | 286.83 | 286.83 | 2.0 | False | None | None | False | None | False | 573.66 | 0 | 3901310 | 150297 | None | code69 | Supply & fixing of LED flood light luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material,delivering superior light output Rated life Burning Hrs 50000hr Lumen Maintenance of 70%, CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. PowerFactor 0.9 with mains, Surge Protection-Min 5KV along with Over voltage /Overload, short circuit/ miss-wiring protection.Compatible for pole mauling with outer dia of 40 mm to 50mm.Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60 Hz application.Compliance to IS 10322/IEC60598 ,LM79 & LM80 Adherence with RoHS.UL approved MCPCB.Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools.LED Light fixture with.......W System Power consumption.LED Efficiency 1301m/w, nominal CRI 75.Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008.Housing with supplier wordmark/name shall be Engraved/Embossing on the die cast housing/Body part Warranty of 2 Years against any manufacturing defect working understand ard electrical conditions as mentioned above should be given by LED manufacturer &Cree/Nichia/Lumileds/Osram make LED Source. LED flood light 100W PWD Electrical SR-2023-24, ITEM NO:11.9.2, PAGE NO-46 | Nos | 11529.28 | 11529.28 | 2.0 | False | None | None | False | None | False | 23058.56 | 0 | 3901311 | 150297 | None | code70 | GI/Copper strips for grounding connections, using necessary fixing materials as required.25x3mm GI Strip.PWD Electrical SR-2023-24, ITEM NO:12.58.2 ,CH-12, PAGE NO-54 | Mtr | 99.66 | 99.66 | 40.0 | False | None | None | False | None | False | 3986.4 | 0 | 3901312 | 150297 | None | code71 | 2 mm thick perforated cable GI tray with one xisting MS angle support using necessary GI bolts/nuts and washer or welding as required.(PWD Electrical SR-2023-24, ITEM NO:12.59.2 ,CH-12, PAGE NO-55 300x50mm | Mtr | 713.43 | 713.43 | 10.0 | False | None | None | False | None | False | 7134.3 | 0 | 3901313 | 150297 | None | code72 | Supplying,fixing,wiring,earth electrode for grounding conduits,I.C.cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5m long buried in a pit.The pit should be filled with equal proportion of salt and charcoal 150 mm all-round the pipe to complete depth.The connection from the pipe to the conduit etc.,is to be established through GIwire of size asper lSI specification 7.3.3.of IS 732 using 12mm dia bolts,nuts,washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.PWD Electrical SR-2023-24, ITEM NO:12.56,CH-12, PAGE NO-54 | Nos | 4266.05 | 4266.05 | 2.0 | False | None | None | False | None | False | 8532.1 | 0 |
|