tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1725256241000 | 0 | None | None | Buildings | Construction of Single Classroom in Maadhur Village in H B Halli Tq Vijayanagara Dist. | 1169084.66 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3900128 | 150222 | None | code01 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. 2021-22, V1, Page no 5, Item No 1.4.1 | Cum | 195.3 | 195.3 | 45.01 | False | None | None | False | None | False | 8790.453 | 0 | 3900129 | 150222 | None | code02 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.2021-22, V2, Page no 5, Item No 4.1 | Sqm | 99.75 | 99.75 | 33.76 | False | None | None | False | None | False | 3367.56 | 0 | 3900130 | 150222 | None | code03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates.2021-22, V1, Page no 15, Item No 2.1.3 | Cum | 5831.7 | 5831.7 | 14.98 | False | None | None | False | None | False | 87358.866 | 0 | 3900131 | 150222 | None | code04 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.2021-22, V1, Page no 15, Item No 2.2.1 | Cum | 6277.95 | 6277.95 | 5.74 | False | None | None | False | None | False | 36035.433 | 0 | 3900132 | 150222 | None | code05 | Form work, centering and scaffolding for Foundation, 3% of Basic rate of concrete For Footing. 2021-22, V1, Page no 115 | Cum | 188.34 | 188.34 | 5.74 | False | None | None | False | None | False | 1081.0716 | 0 | 3900133 | 150222 | None | code06 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.2021-22, V1, Page no 7, Item No 1.9 | Cum | 214.2 | 214.2 | 40.45 | False | None | None | False | None | False | 8664.39 | 0 | 3900134 | 150222 | None | code07 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand).2021-22, V2, Page no 9, Item No 5.4. | Cum | 5619.6 | 5619.6 | 19.18 | False | None | None | False | None | False | 107783.928 | 0 | 3900135 | 150222 | None | code08 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement: 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.2021-22, V2, Page no 13, Item No 6.8 | Cum | 7024.5 | 7024.5 | 16.48 | False | None | None | False | None | False | 115763.76 | 0 | 3900136 | 150222 | None | code09 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates.2021-22, V2, Page no 13, Item No 2.1.3 | Cum | 6014.4 | 6014.4 | 1.13 | False | None | None | False | None | False | 6796.272 | 0 | 3900137 | 150222 | None | code10 | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.2021-22, V1, Page no 17, Item No 2.5.2 | Cum | 6495.3 | 6495.3 | 20.5 | False | None | None | False | None | False | 133153.65 | 0 | 3900138 | 150222 | None | code11 | Form work, centering and scaffolding for Coloumns and Piers, 70% of Basic rate of concrete For Footing. 2021-22, V1, Page no 115 | Cum | 4546.71 | 4546.71 | 4.19 | False | None | None | False | None | False | 19050.7149 | 0 | 3900139 | 150222 | None | code12 | Form work, centering and scaffolding for Chajja, Canophy and Other Architectural Projections of Minor Sections, 45% of Basic rate of concrete For Footing. 2021-22, V1, Page no 115 | Cum | 2922.89 | 2922.89 | 0.14 | False | None | None | False | None | False | 409.2046 | 0 | 3900140 | 150222 | None | code13 | Form work, centering and scaffolding for Roof Beams and Lintels of Building, 60% of Basic rate of concrete For Footing. 2021-22, V1, Page no 115 | Cum | 3897.18 | 3897.18 | 4.83 | False | None | None | False | None | False | 18823.3794 | 0 | 3900141 | 150222 | None | code14 | Form work, centering and scaffolding for Plinth Beam and Roof Slab of Building, 50% of Basic rate of concrete For Footing. 2021-22, V1, Page no 115 | Cum | 3247.65 | 3247.65 | 11.35 | False | None | None | False | None | False | 36860.8275 | 0 | 3900142 | 150222 | None | code15 | Providing Thermo-Mechanically Treated bars of grade Fe-550 or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members wherever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately).2021-22, V2, Page no 84, Item No 11.32 | Kg | 96.6 | 96.6 | 2472.15 | False | None | None | False | None | False | 238809.69 | 0 | 3900143 | 150222 | None | code16 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer in charge.2021-22, V2, Page no 133, Item No 15.1 | Sqm | 782.25 | 782.25 | 55.43 | False | None | None | False | None | False | 43360.1175 | 0 | 3900144 | 150222 | None | code17 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.2021-22, V2, Page no 41, Item No 8.2.1 | Sqm | 260.4 | 260.4 | 69.86 | False | None | None | False | None | False | 18191.544 | 0 | 3900145 | 150222 | None | code18 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement: 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.2021-22, V2, Page no 42, Item No 8.9 | Sqm | 338.1 | 338.1 | 160.63 | False | None | None | False | None | False | 54309.003 | 0 | 3900146 | 150222 | None | code19 | Providing and applying white cement based putty of average
thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.2021-22, V2, Page no 50, Item No 8.51 | Sqm | 87.15 | 87.15 | 51.66 | False | None | None | False | None | False | 4502.169 | 0 | 3900147 | 150222 | None | code20 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.2021-22, V2, Page no 75, Item No 11.5.1 | Sqm | 3843.0 | 3843.0 | 2.21 | False | None | None | False | None | False | 8493.03 | 0 | 3900148 | 150222 | None | code21 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.2021-22, V2, Page no 77, Item No 11.11.1 | Kg | 126.0 | 126.0 | 172.8 | False | None | None | False | None | False | 21772.8 | 0 | 3900149 | 150222 | None | code22 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.2021-22, V2, Page no 85, Item No 11.34A | Sqm | 152.25 | 152.25 | 136.08 | False | None | None | False | None | False | 20718.18 | 0 | 3900150 | 150222 | None | code23 | Flooring with 25mm thick polished tandur blue stone slabs using cement
mortar 1:6, 25mm thick over existing cement concrete bed or top of roof
laid to line and level and jointed with cement slurry mixed with pigment
to match the shade of the slab, , including cost of materials, labour, curing,polishing complete as per specifications.2021-22, V2, Page no 64, Item No 9.34 | Sqm | 1251.56 | 1251.56 | 53.24 | False | None | None | False | None | False | 66633.0544 | 0 | 3900151 | 150222 | None | code24 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser, treads of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints as per direction of Engineer in charge.V2, Page no 62, Item No 9.19 | Sqm | 1294.65 | 1294.65 | 3.83 | False | None | None | False | None | False | 4958.5095 | 0 | 3900152 | 150222 | None | code25 | Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete.2021-22, V2, Page no 59, Item No 9.1 | Sqm | 420.0 | 420.0 | 31.59 | False | None | None | False | None | False | 13267.8 | 0 | 3900153 | 150222 | None | code26 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.2021-22, V2, Page no 45, Item No 8.25 | Sqm | 110.25 | 110.25 | 125.86 | False | None | None | False | None | False | 13876.065 | 0 | 3900154 | 150222 | None | code27 | Finishing walls with water proofing cement paint of required shade New work (Two coats applied @ 4.84 kg/10 m) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.2021-22, V2, Page no 45, Item No 8.28 | Sqm | 69.3 | 69.3 | 164.97 | False | None | None | False | None | False | 11432.421 | 0 | 3900155 | 150222 | None | code28 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.2021-22, V2, Page no 48, Item No 8.40 | Sqm | 94.5 | 94.5 | 17.52 | False | None | None | False | None | False | 1655.64 | 0 | 3900156 | 150222 | None | code29 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.2021-22, V2, Page no 82, Item No 11.25.2 | Sqm | 126.0 | 126.0 | 134.95 | False | None | None | False | None | False | 17003.7 | 0 | 3900157 | 150222 | None | code30 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 110mm dia.2021-22, V5, Item No 2.2 | Rmtr | 284.55 | 284.55 | 12.0 | False | None | None | False | None | False | 3414.6 | 0 | 3900158 | 150222 | None | code31 | Cement Board, 2021-22, V2, Item No 106, Pno-A-15 | Sqm | 246.75 | 246.75 | 2.88 | False | None | None | False | None | False | 710.64 | 0 | 3900159 | 150222 | None | code32 | Chicken Mesh, 2021-22, V2, Item No 114, Pno-A-15 | Sqm | 12.6 | 12.6 | 62.08 | False | None | None | False | None | False | 782.208 | 0 | 3900160 | 150222 | None | code33 | Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, in Charge & MoRTH specification 804
transportation, and labour etc complete.2021-22, V3, Page no 151, Item No 21-C(4) | Nos | 9450.0 | 9450.0 | 1.0 | False | None | None | False | None | False | 9450.0 | 0 | 3900161 | 150222 | None | code34 | Concealed Conduit System : Supplying heavy gauge PVC conduit pipe ...... mm da........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. PWD EL SR 2022-23/ Page No 2, Item No 1.2.2 | Rmtr | 70.0 | 70.0 | 100.0 | False | None | None | False | None | False | 7000.0 | 0 | 3900162 | 150222 | None | code35 | Supplying heavy gauge PVC Conduit Pipe .... dia....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.PWD EL SR 2022-23/ Page No 2, Item No 1.3.2 | Rmtr | 80.0 | 80.0 | 100.0 | False | None | None | False | None | False | 8000.0 | 0 | 3900163 | 150222 | None | code36 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.- 180x90x65mm.PWD EL SR 2022-23/ Page No 2, Item No 1.4.4 | Each | 155.0 | 155.0 | 1.0 | False | None | None | False | None | False | 155.0 | 0 | 3900164 | 150222 | None | code37 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. (300x300x76mm).PWD EL SR 2022-23/ Page No 3, Item No 1.6.1 | Each | 112.0 | 112.0 | 1.0 | False | None | None | False | None | False | 112.0 | 0 | 3900165 | 150222 | None | code38 | Supplying of …feet -PVC Batten with integrated LED tube Specification asper SanctionedEstimate LED light fitting 1 x 4' 20/22 W Item No PWD EL SR 2022-23/ Page No 74, Item No 11.32. | Each | 740.0 | 740.0 | 5.0 | False | None | None | False | None | False | 3700.0 | 0 | 3900166 | 150222 | None | code39 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system - 48" Sweep (1200mm) Regular model.PWD EL SR 2022-23/ Page No 46, Item No 7.3.1 | Each | 2085.0 | 2085.0 | 4.0 | False | None | None | False | None | False | 8340.0 | 0 | 3900167 | 150222 | None | code40 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral)& 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch.PWD EL SR 2022-23/ Page No 05, Item No 2.1.1. | Point | 276.0 | 276.0 | 2.0 | False | None | None | False | None | False | 552.0 | 0 | 3900168 | 150222 | None | Code40 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral)& 1x1.0 mm2 (Earth wire) FRLS multi
strand PVC insulated copper wire(confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch.PWD EL SR 2022-23/ Page No 05, Item No 2.1.2 | Point | 386.0 | 386.0 | 2.0 | False | None | None | False | None | False | 772.0 | 0 | 3900169 | 150222 | None | code41 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi trand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch.PWD EL SR 2022-23/ Page No 05, Item No 2.1.3 | Point | 567.0 | 567.0 | 2.0 | False | None | None | False | None | False | 1134.0 | 0 | 3900170 | 150222 | None | code41 | Supplying 6A flush type socket and 6 A flush type SP switch cither surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 - 6Amps 3/5 Way.PWD EL SR 2022-23/ Page No 09, Item No 3.1.2 | Each | 143.0 | 143.0 | 6.0 | False | None | None | False | None | False | 858.0 | 0 | 3900171 | 150222 | None | code41 | Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N. F. screws.PWD EL SR 2022-23/ Page No 10, Item No 3.9 | Sq CM | 0.26 | 0.26 | 300.0 | False | None | None | False | None | False | 78.0 | 0 | 3900172 | 150222 | None | code41 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.PWD EL SR 2022-23/ Page No 27, Item No 5.17.4 | Each | 1103.0 | 1103.0 | 1.0 | False | None | None | False | None | False | 1103.0 | 0 |
| 1725256241000 | 0 | None | None | Buildings | Construction of Single Classroom in Nelkudri2 Village in H B Halli Tq Vijayanagara Dist. | 1169084.66 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3900173 | 150223 | None | code01 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. 2021-22, V1, Page no 5, Item No 1.4.1 | Cum | 195.3 | 195.3 | 45.01 | False | None | None | False | None | False | 8790.453 | 0 | 3900174 | 150223 | None | code02 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.2021-22, V2, Page no 5, Item No 4.1 | Sqm | 99.75 | 99.75 | 33.76 | False | None | None | False | None | False | 3367.56 | 0 | 3900175 | 150223 | None | code03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates.2021-22, V1, Page no 15, Item No 2.1.3 | Cum | 5831.7 | 5831.7 | 14.98 | False | None | None | False | None | False | 87358.866 | 0 | 3900176 | 150223 | None | code04 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.2021-22, V1, Page no 15, Item No 2.2.1 | Cum | 6277.95 | 6277.95 | 5.74 | False | None | None | False | None | False | 36035.433 | 0 | 3900177 | 150223 | None | code05 | Form work, centering and scaffolding for Foundation, 3% of Basic rate of concrete For Footing. 2021-22, V1, Page no 115 | Cum | 188.34 | 188.34 | 5.74 | False | None | None | False | None | False | 1081.0716 | 0 | 3900178 | 150223 | None | code06 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.2021-22, V1, Page no 7, Item No 1.9 | Cum | 214.2 | 214.2 | 40.45 | False | None | None | False | None | False | 8664.39 | 0 | 3900179 | 150223 | None | code07 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand).2021-22, V2, Page no 9, Item No 5.4. | Cum | 5619.6 | 5619.6 | 19.18 | False | None | None | False | None | False | 107783.928 | 0 | 3900180 | 150223 | None | code08 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement: 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.2021-22, V2, Page no 13, Item No 6.8 | Cum | 7024.5 | 7024.5 | 16.48 | False | None | None | False | None | False | 115763.76 | 0 | 3900181 | 150223 | None | code09 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates.2021-22, V2, Page no 13, Item No 2.1.3 | Cum | 6014.4 | 6014.4 | 1.13 | False | None | None | False | None | False | 6796.272 | 0 | 3900182 | 150223 | None | code10 | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.2021-22, V1, Page no 17, Item No 2.5.2 | Cum | 6495.3 | 6495.3 | 20.5 | False | None | None | False | None | False | 133153.65 | 0 | 3900183 | 150223 | None | code11 | Form work, centering and scaffolding for Coloumns and Piers, 70% of Basic rate of concrete For Footing. 2021-22, V1, Page no 115 | Cum | 4546.71 | 4546.71 | 4.19 | False | None | None | False | None | False | 19050.7149 | 0 | 3900184 | 150223 | None | code12 | Form work, centering and scaffolding for Chajja, Canophy and Other Architectural Projections of Minor Sections, 45% of Basic rate of concrete For Footing. 2021-22, V1, Page no 115 | Cum | 2922.89 | 2922.89 | 0.14 | False | None | None | False | None | False | 409.2046 | 0 | 3900185 | 150223 | None | code13 | Form work, centering and scaffolding for Roof Beams and Lintels of Building, 60% of Basic rate of concrete For Footing. 2021-22, V1, Page no 115 | Cum | 3897.18 | 3897.18 | 4.83 | False | None | None | False | None | False | 18823.3794 | 0 | 3900186 | 150223 | None | code14 | Form work, centering and scaffolding for Plinth Beam and Roof Slab of Building, 50% of Basic rate of concrete For Footing. 2021-22, V1, Page no 115 | Cum | 3247.65 | 3247.65 | 11.35 | False | None | None | False | None | False | 36860.8275 | 0 | 3900187 | 150223 | None | code15 | Providing Thermo-Mechanically Treated bars of grade Fe-550 or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members wherever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately).2021-22, V2, Page no 84, Item No 11.32 | Kg | 96.6 | 96.6 | 2472.15 | False | None | None | False | None | False | 238809.69 | 0 | 3900188 | 150223 | None | code16 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer in charge.2021-22, V2, Page no 133, Item No 15.1 | Sqm | 782.25 | 782.25 | 55.43 | False | None | None | False | None | False | 43360.1175 | 0 | 3900189 | 150223 | None | code17 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.2021-22, V2, Page no 41, Item No 8.2.1 | Sqm | 260.4 | 260.4 | 69.86 | False | None | None | False | None | False | 18191.544 | 0 | 3900190 | 150223 | None | code18 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement: 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.2021-22, V2, Page no 42, Item No 8.9 | Sqm | 338.1 | 338.1 | 160.63 | False | None | None | False | None | False | 54309.003 | 0 | 3900191 | 150223 | None | code19 | Providing and applying white cement based putty of average
thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.2021-22, V2, Page no 50, Item No 8.51 | Sqm | 87.15 | 87.15 | 51.66 | False | None | None | False | None | False | 4502.169 | 0 | 3900192 | 150223 | None | code20 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.2021-22, V2, Page no 75, Item No 11.5.1 | Sqm | 3843.0 | 3843.0 | 2.21 | False | None | None | False | None | False | 8493.03 | 0 | 3900193 | 150223 | None | code21 | Providing and fixing factory made ISI marked steel glazed doors, windows and ventilators, side /top /centre hung, with beading and all members such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted, including providing and fixing of hinges, pivots, including priming coat of approved steel primer, but excluding the cost of other fittings, complete all as per approved design, (sectional weight of only steel members shall be measured for payment). Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.2021-22, V2, Page no 77, Item No 11.11.1 | Kg | 126.0 | 126.0 | 172.8 | False | None | None | False | None | False | 21772.8 | 0 | 3900194 | 150223 | None | code22 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.2021-22, V2, Page no 85, Item No 11.34A | Sqm | 152.25 | 152.25 | 136.08 | False | None | None | False | None | False | 20718.18 | 0 | 3900195 | 150223 | None | code23 | Flooring with 25mm thick polished tandur blue stone slabs using cement
mortar 1:6, 25mm thick over existing cement concrete bed or top of roof
laid to line and level and jointed with cement slurry mixed with pigment
to match the shade of the slab, , including cost of materials, labour, curing,polishing complete as per specifications.2021-22, V2, Page no 64, Item No 9.34 | Sqm | 1251.56 | 1251.56 | 53.24 | False | None | None | False | None | False | 66633.0544 | 0 | 3900196 | 150223 | None | code24 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser, treads of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints as per direction of Engineer in charge.V2, Page no 62, Item No 9.19 | Sqm | 1294.65 | 1294.65 | 3.83 | False | None | None | False | None | False | 4958.5095 | 0 | 3900197 | 150223 | None | code25 | Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete.2021-22, V2, Page no 59, Item No 9.1 | Sqm | 420.0 | 420.0 | 31.59 | False | None | None | False | None | False | 13267.8 | 0 | 3900198 | 150223 | None | code26 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.2021-22, V2, Page no 45, Item No 8.25 | Sqm | 110.25 | 110.25 | 125.86 | False | None | None | False | None | False | 13876.065 | 0 | 3900199 | 150223 | None | code27 | Finishing walls with water proofing cement paint of required shade New work (Two coats applied @ 4.84 kg/10 m) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.2021-22, V2, Page no 45, Item No 8.28 | Sqm | 69.3 | 69.3 | 164.97 | False | None | None | False | None | False | 11432.421 | 0 | 3900200 | 150223 | None | code28 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.2021-22, V2, Page no 48, Item No 8.40 | Sqm | 94.5 | 94.5 | 17.52 | False | None | None | False | None | False | 1655.64 | 0 | 3900201 | 150223 | None | code29 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.2021-22, V2, Page no 82, Item No 11.25.2 | Sqm | 126.0 | 126.0 | 134.95 | False | None | None | False | None | False | 17003.7 | 0 | 3900202 | 150223 | None | code30 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 110mm dia.2021-22, V5, Item No 2.2 | Rmtr | 284.55 | 284.55 | 12.0 | False | None | None | False | None | False | 3414.6 | 0 | 3900203 | 150223 | None | code31 | Cement Board, 2021-22, V2, Item No 106, Pno-A-15 | Sqm | 246.75 | 246.75 | 2.88 | False | None | None | False | None | False | 710.64 | 0 | 3900204 | 150223 | None | code32 | Chicken Mesh, 2021-22, V2, Item No 114, Pno-A-15 | Sqm | 12.6 | 12.6 | 62.08 | False | None | None | False | None | False | 782.208 | 0 | 3900205 | 150223 | None | code33 | Providing and fixing board displaying information, such as 'Name of work, Tender cost, Name of Contractor, Work completion and liability period etc', having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border / messages / symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm, 3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including, excavation, refilling, in Charge & MoRTH specification 804
transportation, and labour etc complete.2021-22, V3, Page no 151, Item No 21-C(4) | Nos | 9450.0 | 9450.0 | 1.0 | False | None | None | False | None | False | 9450.0 | 0 | 3900206 | 150223 | None | code34 | Concealed Conduit System : Supplying heavy gauge PVC conduit pipe ...... mm da........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. PWD EL SR 2022-23/ Page No 2, Item No 1.2.2 | Rmtr | 70.0 | 70.0 | 100.0 | False | None | None | False | None | False | 7000.0 | 0 | 3900207 | 150223 | None | code35 | Supplying heavy gauge PVC Conduit Pipe .... dia....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.PWD EL SR 2022-23/ Page No 2, Item No 1.3.2 | Rmtr | 80.0 | 80.0 | 100.0 | False | None | None | False | None | False | 8000.0 | 0 | 3900208 | 150223 | None | code36 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.- 180x90x65mm.PWD EL SR 2022-23/ Page No 2, Item No 1.4.4 | Each | 155.0 | 155.0 | 1.0 | False | None | None | False | None | False | 155.0 | 0 | 3900209 | 150223 | None | code37 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. (300x300x76mm).PWD EL SR 2022-23/ Page No 3, Item No 1.6.1 | Each | 112.0 | 112.0 | 1.0 | False | None | None | False | None | False | 112.0 | 0 | 3900210 | 150223 | None | code38 | Supplying of ...feet -PVC Batten with integrated LED tube ....As Per Sanctioned Estimate LED light fitting 1 x 4' 20/22 W. PWD EL SR 2022-23/ Page No 74, Item No 11.32 | Each | 740.0 | 740.0 | 5.0 | False | None | None | False | None | False | 3700.0 | 0 | 3900211 | 150223 | None | code39 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system - 48" Sweep (1200mm) Regular model.PWD EL SR 2022-23/ Page No 46, Item No 7.3.1 | Each | 2085.0 | 2085.0 | 4.0 | False | None | None | False | None | False | 8340.0 | 0 | 3900212 | 150223 | None | code40 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral)& 1x1.0 mm2 (Earth wire) FRLS
multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch.PWD EL SR 2022-23/ Page No 05, Item No 2.1.1 | Point | 276.0 | 276.0 | 2.0 | False | None | None | False | None | False | 552.0 | 0 | 3900213 | 150223 | None | code41 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral)& 1x1.0 mm2 (Earth wire) FRLS multi
strand PVC insulated copper wire(confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch.PWD EL SR 2022-23/ Page No 05, Item No 2.1.2 | Point | 386.0 | 386.0 | 2.0 | False | None | None | False | None | False | 772.0 | 0 | 3900214 | 150223 | None | code42 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi trand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switch.PWD EL SR 2022-23/ Page No 05, Item No 2.1.3 | Point | 567.0 | 567.0 | 2.0 | False | None | None | False | None | False | 1134.0 | 0 | 3900215 | 150223 | None | code43 | Supplying 6A flush type socket and 6 A flush type SP switch cither surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 - 6Amps 3/5 Way.PWD EL SR 2022-23/ Page No 09, Item No 3.1.2 | Each | 143.0 | 143.0 | 6.0 | False | None | None | False | None | False | 858.0 | 0 | 3900216 | 150223 | None | code44 | Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N. F. screws.PWD EL SR 2022-23/ Page No 10, Item No 3.9 | Sq CM | 0.26 | 0.26 | 300.0 | False | None | None | False | None | False | 78.0 | 0 | 3900217 | 150223 | None | code45 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.PWD EL SR 2022-23/ Page No 27, Item No 5.17.4 | Each | 1103.0 | 1103.0 | 1.0 | False | None | None | False | None | False | 1103.0 | 0 |
|
|
---|