3898618 | 150098 | None | lwm-01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work (Page No 8 Item No 1.14 of CSR Vol-1 2023-24) | Cum | 102.0 | 102.0 | 168.0 | False | None | None | False | None | False | 17136.0 | 0 |
3898619 | 150098 | None | lwm-02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates .(P.No.15 I.No. 2.1.3 CSR 2023-24 Vol-1) | Cum | 5989.0 | 5989.0 | 53.05 | False | None | None | False | None | False | 317716.45 | 0 |
3898620 | 150098 | None | lwm-03 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.15 I.No.2.2.1 CSR 2023-24 Vol-1) | Cum | 6789.96 | 6789.96 | 20.24 | False | None | None | False | None | False | 137428.7904 | 0 |
3898621 | 150098 | None | lwm-04 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.15 I.No 2.2.1 CSR 2023-24 Vol -1) | Cum | 10687.9 | 10687.9 | 3.55 | False | None | None | False | None | False | 37942.045 | 0 |
3898622 | 150098 | None | lwm-05 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.15 I.No.2.2.1 CSR 2023-24 Vol-1) | Cum | 9430.5 | 9430.5 | 7.75 | False | None | None | False | None | False | 73086.375 | 0 |
3898623 | 150098 | None | lwm-06 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (P.No.9 I.No.5.4 CSR 2023-2024 Vol-2) | Cum | 6389.0 | 6389.0 | 54.15 | False | None | None | False | None | False | 345964.35 | 0 |
3898624 | 150098 | None | lwm-07 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page No-16 Item No- 2.5.1 of CSR 2023-24 Vol - 1.) | Cum | 11271.0 | 11271.0 | 6.012 | False | None | None | False | None | False | 67761.252 | 0 |
3898625 | 150098 | None | lwm-08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page No-17 Item No- 2.5.1 of CSR 2023-24 Vol - 1.) | Cum | 10608.0 | 10608.0 | 0.82 | False | None | None | False | None | False | 8698.56 | 0 |
3898626 | 150098 | None | lwm-09 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page No-17 Item No- 2.5.1 of CSR 2023-24 Vol - 1.) | Cum | 9613.5 | 9613.5 | 0.303 | False | None | None | False | None | False | 2912.8905 | 0 |
3898627 | 150098 | None | lwm-10 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page No-17 Item No- 2.5.1 of CSR 2023-24 Vol - 1.) | Cum | 9945.0 | 9945.0 | 8.085 | False | None | None | False | None | False | 80405.325 | 0 |
3898628 | 150098 | None | lwm-11 | Steel Fabrication:Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. For Buildings (P. No. 18 I No. 2.11a CSR 2023-24 Vol -1) | Kg | 89497.0 | 89497.0 | 3.84 | False | None | None | False | None | False | 343668.48 | 0 |
3898629 | 150098 | None | lwm-12 | Filling available excavated earth ( excluding rock ) in sides of foundations upto plinthin layers not exceeding 20 cms. in depth, compacting each deposited layer by ramming afterwatering with lead upto 50 m. and lift upto 1.5 m. including cost of all labour complete as perspecifications. (P.No.07 I.No. 1.9 CSR 2023-24 Vol - 1) | Cum | 266.0 | 266.0 | 85.65 | False | None | None | False | None | False | 22782.9 | 0 |
3898630 | 150098 | None | lwm-13 | Providing and constructing load bearing wall with solid concrete blocks having block density not less than 1800kg/m3 having a minimum average compressive strength of 5.00 N/mm2 confirming to IS 2185 (Part 1):2005 and constructed with CM 1:4, as per IS 2572:2005 including cost of all materials labour charges, scaffolding, curing, hire charges of machineries etc., complete as per specifications . do - with solid concrete blocks of size 400x200x200mm (P.No.17 I.No.6.34 CSR 2023-24 Vol-2) | Sqm | 1104.0 | 1104.0 | 178.631 | False | None | None | False | None | False | 197208.624 | 0 |
3898631 | 150098 | None | lwm-14 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge (P.No.83 I.No.11.16.3 CSR 2023-24 Vol-2) | Kg | 122.0 | 122.0 | 3213.45 | False | None | None | False | None | False | 392040.9 | 0 |
3898632 | 150098 | None | lwm-15 | PROVIDING TRAPEZOIDAL PROFILED SHEET Providing and installing of pre painted Galvo-lume iron Trapezoidal profiled sheet of approved make 1060 mm width (1000 mm cover width), 28-30 mm crest height with crest distance of 200 mm c/c with 2 ribs at the centre for stiffening. The total coated thickness (TCT) of the sheet will be 0.47 mm +/- 0.02 mm tolerance Zinc-Alu Alloy coating AZ150 gsm as per ASTM 397/A 755-550 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 20-22 microns using self drilling/self tapping screws of 25 mm length, to be fixed over the existing purlins, rafters, channels and trusses. . (P.No.299 I.No.38.30 PWD SR 2018-19) | Sqm | 688.0 | 688.0 | 365.84 | False | None | None | False | None | False | 251697.92 | 0 |
3898633 | 150098 | None | lwm-16 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour,usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge (P. No.78 I. No.11.6.1 CSR. 2023-24 Vol - 2) | Sqm | 2633.0 | 2633.0 | 14.71 | False | None | None | False | None | False | 38731.43 | 0 |
3898634 | 150098 | None | lwm-17 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P. No.77 I. No.11.5.2 CSR. 2023-24 Vol - 2) | Sqm | 4242.0 | 4242.0 | 6.72 | False | None | None | False | None | False | 28506.24 | 0 |
3898635 | 150098 | None | lwm-18 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge (P. No.59 I. No. 9.2 CSR. 2023-24 Vol - 2) | Sqm | 800.0 | 800.0 | 251.44 | False | None | None | False | None | False | 201152.0 | 0 |
3898636 | 150098 | None | lwm-19 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (P. No.41 I. No. 8.4.1 CSR. 2023-24 Vol - 2) | Sqm | 323.0 | 323.0 | 70.05 | False | None | None | False | None | False | 22626.15 | 0 |
3898637 | 150098 | None | lwm-20 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (P. No.42 I. No. 8.9 CSR. 2023-24 Vol - 2) | Sqm | 385.0 | 385.0 | 405.01 | False | None | None | False | None | False | 155928.85 | 0 |
3898638 | 150098 | None | lwm-21 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (P. No.41 I. No. 8.2.1 CSR. 2023-24 Vol - 2) | Sqm | 295.0 | 295.0 | 212.6 | False | None | None | False | None | False | 62717.0 | 0 |
3898639 | 150098 | None | lwm-22 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. (P. No.65 I. No. 9.39 CSR. 2023-24 Vol - 2) | Sqm | 1449.0 | 1449.0 | 39.06 | False | None | None | False | None | False | 56597.94 | 0 |
3898640 | 150098 | None | lwm-23 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (P. No.60 I. No. 9.11 CSR. 2023-24 Vol - 2) | Sqm | 889.0 | 889.0 | 12.899 | False | None | None | False | None | False | 11467.211 | 0 |
3898641 | 150098 | None | lwm-24 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (P. No. 50 I. No. 8.51 CSR. 2023-24 Vol - 2) | Sqm | 100.0 | 100.0 | 39.06 | False | None | None | False | None | False | 3906.0 | 0 |
3898642 | 150098 | None | lwm-25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (P. No. 45 I. No. 8.25 CSR. 2023-24 Vol - 2) | Sqm | 137.0 | 137.0 | 178.931 | False | None | None | False | None | False | 24513.547 | 0 |
3898643 | 150098 | None | lwm-26 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (P. No. 45 I. No. 8.2.8 CSR. 2023-24 Vol - 2) | Sqm | 89.0 | 89.0 | 438.72 | False | None | None | False | None | False | 39046.08 | 0 |
3898644 | 150098 | None | lwm-27 | Supplying & errection of RCC rings for well steini-ng of 0.3Mtr Depth using M-20 grade concrete using clean graded granite ortrap or jelly of approved quali- ty 20mm and down size well compacted including ce-ntering,formwork and plastering for both faces with C.M 1:3 proportion as per design using 6.50mm MS coil at the rate of10Kgs/ring including cost of steel and fabrication,bailing out of water,errection etc., complete.For 1.20m dia (clear) rings of steining thickness 0.075mm upto 18 M depth Page No40Item No4.63of RWSSR 2019-20 | No | 1109.0 | 1109.0 | 10.0 | False | None | None | False | None | False | 11090.0 | 0 |
3898645 | 150098 | None | lwm-28 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. (P. No.131 I. No. 14.1.1 CSR. 2023-24 Vol - 2) | No | 4884.0 | 4884.0 | 1.0 | False | None | None | False | None | False | 4884.0 | 0 |
3898646 | 150098 | None | lwm-29 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost od CI frame cover (P. No.191 I. No. 16.9 CSR. 2023-24 Vol - 5) | Cum | 4977.0 | 4977.0 | 2.0 | False | None | None | False | None | False | 9954.0 | 0 |
3898647 | 150098 | None | lwm-30 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineer-in-charge. (P. No.95 I. No. 11.6 CSR. 2023-24 Vol - 2) | Sqm | 841.0 | 841.0 | 43.56 | False | None | None | False | None | False | 36633.96 | 0 |
3898648 | 150098 | None | lwm-31 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required. W.C. pan with ISI marked white solid plastic seat and lid (P. No.131 I. No.14.3.1 CSR. 2022-23 Vol - 2) | Nos | 5977.0 | 5977.0 | 1.0 | False | None | None | False | None | False | 5977.0 | 0 |
3898649 | 150098 | None | lwm-32 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (P.No.47 I.No.8.33.3 CSR 2023-24 Vol-2) | Sqm | 139.0 | 139.0 | 45.85 | False | None | None | False | None | False | 6373.15 | 0 |
3898650 | 150098 | None | lwm-33 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (P.No.13 I.No. 6.2 CSR 2023-24 Vol - 2) | Cum | 7978.0 | 7978.0 | 25.6 | False | None | None | False | None | False | 204236.8 | 0 |
3898651 | 150098 | None | lwm-34 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (P.No.13 I.No. 6.1 CSR 2023-24 Vol-1) | Cum | 8220.0 | 8220.0 | 6.65 | False | None | None | False | None | False | 54663.0 | 0 |
3898652 | 150098 | None | lwm-35 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (P.No.15 I.No 2.2.1 CSR 2023-24 Vol -1) | Cum | 6475.61 | 6475.61 | 2.2 | False | None | None | False | None | False | 14246.342 | 0 |
3898653 | 150098 | None | lwm-36 | Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (P. No.42 I. No. 8.6.2 CSR. 2023-24 Vol - 2 | Sqm | 429.0 | 429.0 | 25.0 | False | None | None | False | None | False | 10725.0 | 0 |
3898654 | 150098 | None | lwm-37 | Providing and fixing plaster mesh 100mm wide manufactured out of hot dipped gal-vanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm wi-dth, along route of walls chipped for servic-es, junction between RCC and brick walls including cost of materials,labour for fixing complete as per specifications.(length of mesh only be measured for payment )sui-table plaster mesh 100mm wide. Page No 77 Item No 9.30 of RWS SR 2019-20 | No | 25.0 | 25.0 | 250.0 | False | None | None | False | None | False | 6250.0 | 0 |
3898655 | 150098 | None | lwm-38 | Providing and fixing MS inspection door of size 60 cms x 60 cms, including MS frame made of 50x50x6mm angle, shutters made of 3mm thick MS sheets, with hinges, locking arrangements at top etc. including painting with anticorrosive approved paint etc. complete including all lead and lifts etc. etc. ((P. No.85 I. No.7.3, CSR. 2022-23 Vol - 5) | No | 2140.0 | 2140.0 | 1.0 | False | None | None | False | None | False | 2140.0 | 0 |
3898656 | 150098 | None | lwm-39 | Supplying heavy gauge PVC conduit pipe ..mm dia.. .mm thick confirming to IS2509with suitable size bends, metal/PVC Junct-ion boxes, adhesive paste etc., and running before concreting the slab.The conduit should be tied tothe reinforcement rods by using bindingwires and unused waysof junction boxes and pipe ends should be covered using PVC end enclosures,runwith 18 SWG GI fishwire wherever necessary. 40mm dia | Rmtr | 147.0 | 147.0 | 5.0 | False | None | None | False | None | False | 735.0 | 0 |
3898657 | 150098 | None | lwm-40 | Supplying heavy gauge PVC conduit pipe ..mm dia.. .mm thick confirming to IS2509with suitable size bends, metal/PVC Junct-ion boxes, adhesive paste etc., and running before concreting the slab.The conduit should be tied tothe reinforcement rods by using bindingwires and unused waysof junction boxes and pipe ends should be covered using PVC end enclosures,runwith 18 SWG GI fishwire wherever necessary.32mm dia | Rmtr | 103.0 | 103.0 | 10.0 | False | None | None | False | None | False | 1030.0 | 0 |
3898658 | 150098 | None | lwm-41 | Supplying heavy gauge PVC conduit pipe ..mm dia.. .mm thick confirming to IS2509with suitable size bends, metal/PVC Junct-ion boxes, adhesive paste etc., and running before concreting the slab.The conduit should be tied tothe reinforcement rods by using bindingwires and unused waysof junction boxes and pipe ends should be covered using PVC end enclosures,runwith 18 SWG GI fishwire wherever necessary.25mm dia | Rmtr | 78.0 | 78.0 | 10.0 | False | None | None | False | None | False | 780.0 | 0 |
3898659 | 150098 | None | lwm-42 | Supplying and fixing PBBC Bakelite staight or slant batten Lamp holder 70-150 watts 2 pin Page No -XXIV ItemNo 797 of Electrical SR Bangalore circle 2019-20 | Nos | 63.6 | 63.6 | 10.0 | False | None | None | False | None | False | 636.0 | 0 |
3898660 | 150098 | None | lwm-43 | Supplying and fixing /replacing of 6/16/32 Amps electrical accessories on switch bord of16A SP switch Page No11 Item No3.14.9of Electrical SR2019-20 | Nos | 68.0 | 68.0 | 15.0 | False | None | None | False | None | False | 1020.0 | 0 |
3898661 | 150098 | None | lwm-44 | Supplying and flush mounting teak wooden box without front plank, made out of not less than 12 mm thick wood after due groove cutting, necess-ary masonry patch work complete.300x600x76 Basic Rate | Nos | 120.0 | 120.0 | 1.0 | False | None | None | False | None | False | 120.0 | 0 |
3898662 | 150098 | None | lwm-45 | Supplying and flush mounting teak wooden box without front plank, made out of not less than 12 mm thick wood after due groove cutting, necess-ary masonry patch work complete.254x178x76 Basic Rate | Nos | 112.0 | 112.0 | 1.0 | False | None | None | False | None | False | 112.0 | 0 |
3898663 | 150098 | None | lwm-46 | Supplying and flush mounting teak wooden box without front plank, made out of not less than 12 mm thick wood after due groove cutting, necess-ary masonry patch work complete.203x152x76 Basic Rate | Nos | 86.0 | 86.0 | 1.0 | False | None | None | False | None | False | 86.0 | 0 |
3898664 | 150098 | None | lwm-47 | Supplying and flush mounting teak wooden box without front plank, made out of not less than 12 mm thick wood after due groove cutting, necess-ary masonry patch work complete.1 to 2 way Basic Rate | Nos | 43.0 | 43.0 | 1.0 | False | None | None | False | None | False | 43.0 | 0 |
3898665 | 150098 | None | lwm-48 | Supplying and flush mounting teak wooden box without front plank, made out of not less than 12 mm thick wood after due groove cutting, necess-ary masonry patch work complete. 3 to 4 way Basic Rate | Nos | 47.0 | 47.0 | 1.0 | False | None | None | False | None | False | 47.0 | 0 |
3898666 | 150098 | None | lwm-49 | Supplying and fixing32amps security and energy saving DPswitch with key tag suitable to operate on 230volts, 50hzs AC supply and completely wired on eixsting box A grade (Page 9 of 105 /Item No 3.7of PWD CSR Electrical 2023-24) | Nos | 747.0 | 747.0 | 1.0 | False | None | None | False | None | False | 747.0 | 0 |
3898667 | 150098 | None | lwm-50 | Supplying and fixing /replacing of 6/16/32 Amps electrical accessories on switch bord of 16A 3way5 pin socket (Page 10 of 105 /Item No 3.7of PWD CSR Electrical 2023-24) | Nos | 115.0 | 115.0 | 5.0 | False | None | None | False | None | False | 575.0 | 0 |
3898668 | 150098 | None | lwm-51 | Supplying of switch disconnector fuse unit (TPN)HRC type(But without HRC fuses) with AC 23A duty and As per IS 13947 125 amps (Page 15 of 105 /Item No 3.7of PWD CSR Electrical 2023-24) | Nos | 5798.0 | 5798.0 | 1.0 | False | None | None | False | None | False | 5798.0 | 0 |
3898669 | 150098 | None | lwm-52 | Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70 lumen maintena-nce with CRI 80. Power Input: 220240V @ 50/ 60Hz & Power factor 0.9 along with CE approved . 2 years Warranty against any manufacturing defect working under standard electrical conditi-on. LED light fighting 1 x4'- 20/22 w (Page 43 of 105 /Item No 3.7of PWD CSR Electrical 2023-24) | Nos | 690.0 | 690.0 | 6.0 | False | None | None | False | None | False | 4140.0 | 0 |
3898670 | 150098 | None | lwm-53 | Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using2x 1.5Sqmm(Phase & Neutral) &1x1.0 sqmm (Earthwire)FRLS multistrand PVCinsulated copper wire (confirming to IS-694: and latest amendme-nts) with a 6Amps flush type SP control switch shall be fixed on the existi-ng plastic sheet/gang box,the other end of the wires shall be terminated with sufficient loose length in a wood/PVC rou-nd block. complete for each outlet. a)Short point upto 3.00m from tapping point to outlet via switch (2.1.1) | Nos | 285.0 | 285.0 | 2.0 | False | None | None | False | None | False | 570.0 | 0 |
3898671 | 150098 | None | lwm-54 | Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using2x 1.5Sqmm(Phase & Neutral) &1x1.0 sqmm (Earthwire)FRLS multistrand PVCinsulated copper wire (confirming to IS-694: and latest amendme-nts) with a 6Amps flush type SP control switch shall be fixed on the existi-ng plastic sheet/gang box,the other end of the wires shall be terminated with sufficient loose length in a wood/PVC rou-nd block. complete for each outlet. b) Medium point above 3.00m upto 6.00 m from tapping point to outlet via switch (2.1.2) | Nos | 394.0 | 394.0 | 3.0 | False | None | None | False | None | False | 1182.0 | 0 |
3898672 | 150098 | None | lwm-55 | Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using2x 1.5Sqmm(Phase & Neutral) &1x1.0 sqmm (Earthwire)FRLS multistrand PVCinsulated copper wire (confirming to IS-694: and latest amendme-nts) with a 6Amps flush type SP control switch shall be fixed on the existi-ng plastic sheet/gang box,the other end of the wires shall be terminated with sufficient loose length in a wood/PVC rou-nd block. complete for each outlet. c) Long point above 6.00m upto 10.00m from tapping point to outlet via switch (2.1.3) | Nos | 570.0 | 570.0 | 3.0 | False | None | None | False | None | False | 1710.0 | 0 |
3898673 | 150098 | None | lwm-56 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230volts,50cycles.Single pha-se ACsupply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm)Regular model (Page 30 of 105 /Item No 6.3.1 of PWD CSR Electrical 2023-24) | Nos | 2984.0 | 2984.0 | 3.0 | False | None | None | False | None | False | 8952.0 | 0 |
3898674 | 150098 | None | lwm-57 | Supplying TPST with rewirable porcelain channels in SM encloure Made out of 14 SWG powder coated paint of approved colour for 32 amps (Page 14 of 105 /Item No 5.5.1 of PWD CSR Electrical 2023-24) | Nos | 1701.0 | 1701.0 | 2.0 | False | None | None | False | None | False | 3402.0 | 0 |
3898675 | 150098 | None | lwm-58 | Supplying and fixing of porcelene fuse channel with cutout on Existing wooden/panel uisng necessary nuts, bolts abnd washers for 100amps capacity (Page 14 of 105 /Item No 5.7.4 of PWD CSR Electrical 2023-24) | Nos | 691.0 | 691.0 | 3.0 | False | None | None | False | None | False | 2073.0 | 0 |
3898676 | 150098 | None | lwm-59 | Supplying and fixing HRC Fuse units base on existing switch/panel board for 32amps to 63 amps capacity (Page 15 of 105 /Item No 5.9.2 of PWD CSR Electrical 2023-24) | Nos | 612.0 | 612.0 | 3.0 | False | None | None | False | None | False | 1836.0 | 0 |
3898677 | 150098 | None | lwm-60 | Supplying and fixing HRC Fuse link on existing switch fuse base as \per IS 13703for 63 to 200 amps capacity (Page 15 of 105 /Item No 5.10.2 of PWD CSR Electrical 2023-24) | Nos | 381.0 | 381.0 | 3.0 | False | None | None | False | None | False | 1143.0 | 0 |
3898678 | 150098 | None | lwm-61 | Supplying and fiing regular MCB distribution bo-ards on wall/wood board/flush mounting using required clamps bolts nuts ect with provision for fixing suit-able MCB's single phase / three phase Single door with powder coated painting made out of 18SWG MS enclousre ect.complete 12way SP & N (Page 18 of 105 /Item No 5.19.4 of PWD CSR Electrical 2023-24) | Nos | 1863.0 | 1863.0 | 3.0 | False | None | None | False | None | False | 5589.0 | 0 |
3898679 | 150098 | None | lwm-62 | Supplying and fixing miniature circuit breakers on exisitng MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OfFF , energy cross-3 with shirt circit breaking capacity of 10K and complete wiring as reuqired to IEC 60898 for 6-+32 Amps SP (Page 17 of 105 /Item No 5.18.1 of PWD CSR Electrical 2023-24) | Nos | 415.0 | 415.0 | 36.0 | False | None | None | False | None | False | 14940.0 | 0 |
3898680 | 150098 | None | lwm-63 | Supplying and fixing and wiring Earth leakage Miniature circuit breakers(ELMCB) 240/450 volts upto 300MA Sensitivity on Exisitng wood/ panel board32-40 Amps 2 pole Page No28ItemNo 5.20.2 of electrical SR 2019-20 | Nos | 2500.0 | 2500.0 | 1.0 | False | None | None | False | None | False | 2500.0 | 0 |
3898681 | 150098 | None | lwm-64 | Supplying and fixing single phase preventer using necessary wires over an exisiting panel board sui-table for motor upto 20HP capacity (Page 14 of 105 /Item No 5.3 of PWD CSR Electrical 2023-24) | Nos | 904.2 | 904.2 | 1.0 | False | None | None | False | None | False | 904.2 | 0 |
3898682 | 150098 | None | lwm-65 | Supplying and fixing of slim patty fitting made out of CRCA Sheet metal body with locking type holder completely wired. Excluding Ballast & Flour-esent Tube 1 x 4' Tube light fitting (Page 47 of 105 /Item No of 11.13 PWD CSR Electrical 2023-24) | Nos | 269.0 | 269.0 | 8.0 | False | None | None | False | None | False | 2152.0 | 0 |
3898683 | 150098 | None | lwm-66 | wiring for lighting/power circuit using one of FRLS PVCinsulated 1100KV grade Multi strand copper with low conuctor ressistant single core in op-en or concealed system of wiring with Specified IS694 conforming to Latest amanedmdnets .40 sqmm (2.3.5) | Mtr | 63.0 | 63.0 | 40.0 | False | None | None | False | None | False | 2520.0 | 0 |
3898684 | 150098 | None | lwm-67 | wiring for lighting/power circuit using one of FRLS PVCinsulated 1100KV grade Multi strand copper with low conuctor ressistant single core in op-en or concealed system of wiring with Specified IS694 conforming to Latest amanedmdnets .2.5sqmm (2.3.3) | Mtr | 42.0 | 42.0 | 40.0 | False | None | None | False | None | False | 1680.0 | 0 |
3898685 | 150098 | None | lwm-68 | wiring for lighting/power circuit using one of FRLS PVCinsulated 1100KV grade Multi strand copper with low conuctor ressistant single core in op-en or concealed system of wiring with Specified IS694 conforming to Latest amanedmdnets .1.5sqmm (2.3.2) | Mtr | 26.0 | 26.0 | 60.0 | False | None | None | False | None | False | 1560.0 | 0 |
3898686 | 150098 | None | lwm-69 | Supplying and fixing of Electronic Ballast sui-table for T5 Lamp with housing made of Pre-coated steel/PC,Operating voltage rangefrom 180V to 265V,50Hz AC power Supply flicker free warm start with over voltage protection, Inrush current protection, De-activated lamp protection & End of Lamplife protection with PF 0.95& TCdeg C 65deg C.compliance to EN 61347-2-3(Safety), EN60929 (Perform-ance), EN55015(EMI/RFI),EN61000-3-2 (Har-monics EN 61547 Surge.Operating voltage range from 180V to 265V,50Hz AC power Supply.2x14watts Page 49 of 105 /Item No of 12.19.2 PWD CSR Electrical 2023-24 | Nos | 848.0 | 848.0 | 1.0 | False | None | None | False | None | False | 848.0 | 0 |
3898687 | 150098 | None | lwm-70 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm Copper strip (Page 55 of 105 /Item No of 12.58.7 PWD CSR Electrical 2023-24) | Mtr | 570.0 | 570.0 | 1.0 | False | None | None | False | None | False | 570.0 | 0 |
3898688 | 150098 | None | lwm-71 | Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring)using necessary su-itable size clamps, nails,guttas/spacers etc. 8 SWG GI Wire Page No-43Item .No. 6.18.3 Electrical SR of Bangalore circle 2019-20 | Mtr | 19.0 | 19.0 | 10.0 | False | None | None | False | None | False | 190.0 | 0 |
3898689 | 150098 | None | lwm-72 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. (Page 63 of 81 /Item No of 29.02 PWD CSR Electrical 2023-24) | Cum | 260.0 | 260.0 | 7.5 | False | None | None | False | None | False | 1950.0 | 0 |
3898690 | 150098 | None | lwm-73 | Supplying of .1 KV LT UG cable XLPE or He-at resistant PVC insulated, PVC extruded In-ner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average+5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 for 4 core 16sqmm Page No -40 Item .No.6.4.4 Electrical SR of Bangalore circle 2019-20 | Mtr | 150.0 | 150.0 | 20.0 | False | None | None | False | None | False | 3000.0 | 0 |
3898691 | 150098 | None | lwm-74 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required. In existing trench/duct. 6 sqmm to 16swmm Page No -41 Item .No.6.5.1 Electrical SR of Bangalore circle 2019-20 | Mtr | 11.88 | 11.88 | 20.0 | False | None | None | False | None | False | 237.6 | 0 |
3898692 | 150098 | None | lwm-75 | Supplying,fixing,wiring,earth electrode for gro-unding con-duits IC cutouts and other equip-ments on the meter bo-ard using40mm dia 2.90mm thick GI pipe2.5m long buried in a pit. The pit should be filled with equal propor-tion of salt and charcoal150mm alround the pipeto complete depth. The connection from the pipe to the conduit etc,is to be establis-hed through GIwire of size as per ISI specifi-cation7.3.3 of IS732 using 12mm dia bolts and nuts washers and checknuts etc.,the pipe shall have 16 through holes of 12mm dia (Page 54 of 105 /Item No of 29.02 PWD CSR Electrical 2023-24) | Nos | 3510.0 | 3510.0 | 1.0 | False | None | None | False | None | False | 3510.0 | 0 |