createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1723526632847
version5
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee2510.00
emd178500.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose18-09-2024 16:30:00
tenderQueryClose12-09-2024 16:30:00
technicalBidOpen19-09-2024 17:00:00
publishedDate04-09-2024 13:18:26
publishedByPostRDPR_EE_DIV_RCR
publishedByUserKPE14312 - VENKATESH GALAG
bidValidityPeriod90
noOfCalls1
preBidMeetingDate02-09-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonAnand Patil
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber7975468766
tenderSupplierListNone
tenderSchedule
createdTs1723526632898
version4
createdDateNone
modifiedDateNone
tenderNumberRDPR/2024-25/BD/WORK_INDENT6756
titleConstruction of 04 Class Rooms 01 Art / Craft Room and Boys Girlss Toilet Blocks & CWSN Toilet to the GHPS Yelebichali Upgraded RMSA School in Raichur Taluka of Raichur District. (Dise Code 29060715501) (Under Comprehensive Education (PAB) Grant for the year 2022-2023 (Strengthening of Govt Secondary Schools)
descriptionConstruction of 04 Class Rooms 01 Art / Craft Room and Boys Girlss Toilet Blocks & CWSN Toilet to the GHPS Yelebichali Upgraded RMSA School in Raichur Taluka of Raichur District. (Dise Code 29060715501) (Under Comprehensive Education (PAB) Grant for the year 2022-2023 (Strengthening of Govt Secondary Schools)
categoryWORKS
categoryTextWorks
ecv10015967.21
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location963
locationNameRDPR Division Office Raichur
provisionalAmount11900000.0
groupOverheadTotalNone
fileNumberEE/PRED/JE-1/RCR/YELEBICHALI/2023-24
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17235266330000NoneNoneBuildingsConstruction of four Class rooms & one Art / Craft room8527953.94
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3762499141496None001Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the workCum107.1107.1273.66FalseNoneNoneFalseNoneFalse29308.9860
3762500141496None002Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregatesCum6288.456288.4550.12FalseNoneNoneFalseNoneFalse315177.1140
3762501141496None003Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6515.256515.25134.53FalseNoneNoneFalseNoneFalse876496.58250
3762502141496None004Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6708.456708.45124.9FalseNoneNoneFalseNoneFalse837885.4050
3762503141496None005Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For FootingCum6961.56961.521.38FalseNoneNoneFalseNoneFalse148836.870
3762504141496None006Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For ColumnsCum6961.56961.520.49FalseNoneNoneFalseNoneFalse142641.1350
3762505141496None007Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Plinth BeamCum6961.56961.512.54FalseNoneNoneFalseNoneFalse87297.210
3762506141496None008Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For Roof beamCum6961.56961.524.45FalseNoneNoneFalseNoneFalse170208.6750
3762507141496None009Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For SlabCum6961.56961.548.23FalseNoneNoneFalseNoneFalse335753.1450
3762508141496None010Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates For ChajjaCum6961.56961.50.95FalseNoneNoneFalseNoneFalse6613.4250
3762509141496None011Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Centering & shuttering charges For : FootingCum208.84208.8421.38FalseNoneNoneFalseNoneFalse4464.99920
3762510141496None012Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Centering & shuttering charges For : ColumnsCum4873.054873.0520.49FalseNoneNoneFalseNoneFalse99848.79450
3762511141496None013Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Centering & shuttering charges For : Plinth BeamCum3480.753480.7512.54FalseNoneNoneFalseNoneFalse43648.6050
3762512141496None014Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Centering & shuttering charges For : BemasCum4176.94176.924.45FalseNoneNoneFalseNoneFalse102125.2050
3762513141496None015Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Centering & shuttering charges For : ChajjaCum3132.673132.670.95FalseNoneNoneFalseNoneFalse2976.03650
3762514141496None016Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Centering & shuttering charges For : SlabCum3480.753480.7548.23FalseNoneNoneFalseNoneFalse167876.57250
3762515141496None017Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.MT93929.993929.915.37FalseNoneNoneFalseNoneFalse1443702.5630
3762516141496None018Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.3220.65FalseNoneNoneFalseNoneFalse61627.5450
3762517141496None019Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum497.7497.7259.41FalseNoneNoneFalseNoneFalse129108.3570
3762518141496None020Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm8621.68621.698.26FalseNoneNoneFalseNoneFalse847158.4160
3762519141496None021Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ) but including cost of materials, labour, usage charges complete as per specifications.Cum130412.1130412.12.11FalseNoneNoneFalseNoneFalse275169.5310
3762520141496None022Providing and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc.Kgs192.2192.2756.0FalseNoneNoneFalseNoneFalse145303.20
3762521141496None023Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm52.552.581.0FalseNoneNoneFalseNoneFalse4252.50
3762522141496None024Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm120.8120.881.0FalseNoneNoneFalseNoneFalse9784.80
3762523141496None025Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1066.81066.810.0FalseNoneNoneFalseNoneFalse10668.00
3762524141496None026Fixing of window frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos811.7811.720.0FalseNoneNoneFalseNoneFalse16234.00
3762525141496None027Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm267.8267.8309.6FalseNoneNoneFalseNoneFalse82910.880
3762526141496None028Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm404.3404.31060.22FalseNoneNoneFalseNoneFalse428646.9460
3762527141496None029Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer- in-Charge.Kgs593.3593.386.4FalseNoneNoneFalseNoneFalse51261.120
3762528141496None030Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum6527.856527.8537.23FalseNoneNoneFalseNoneFalse243031.85550
3762529141496None031Flooring with 25mm thick polished shahabad slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications.Sqm1717.81717.8341.54FalseNoneNoneFalseNoneFalse586697.4120
3762530141496None032Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures)Sqm6029.16029.125.2FalseNoneNoneFalseNoneFalse151933.320
3762531141496None033Providing and fixing in position Mathi / Nandi wood fully panelled shutters for windows with stiles and rails of 25mm. thick, 75mm wide in two halves with panels of 20mm thick including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures)Sqm6134.16134.136.0FalseNoneNoneFalseNoneFalse220827.60
3762532141496None034Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.Nos126.0126.010.0FalseNoneNoneFalseNoneFalse1260.00
3762533141496None035Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos248.85248.8590.0FalseNoneNoneFalseNoneFalse22396.50
3762534141496None036Providing and fixing aluminium tower bolts, ISI marked, anodised (an- odic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNos136.5136.5160.0FalseNoneNoneFalseNoneFalse21840.00
3762535141496None037Providing M.S. Piano hinges ISI marked IS : 3818 finished with nickel plating and fixing with necessary screws etc., complete.Nos312.9312.9170.0FalseNoneNoneFalseNoneFalse53193.00
3762536141496None038Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm105.0105.0973.44FalseNoneNoneFalseNoneFalse102211.20
3762537141496None039Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm143.85143.85973.44FalseNoneNoneFalseNoneFalse140029.3440
3762538141496None040Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm182.7182.7358.88FalseNoneNoneFalseNoneFalse65567.3760
3762539141496None041Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm55.6555.65137.7FalseNoneNoneFalseNoneFalse7663.0050
3762540141496None042Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm144.9144.9137.7FalseNoneNoneFalseNoneFalse19952.730
3762541141496None043Providing wall black boards in 12mm thick with CM 1:3 and applied with primer & two coats of acrylic emulsion black paint including finishing etc.,complete.Sqm498.75498.7528.8FalseNoneNoneFalseNoneFalse14364.00
17235266330000NoneNoneBuildingsFor Electrification Work120758.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3762542141497None001Concealed Conduit System Supplying heavy gauge PVC conduit pipe ……mm dia .mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and runningbefore concreting the slab. The conduit should be tied to thereinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered usingPVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2mm thickMtr66.066.0200.0FalseNoneNoneFalseNoneFalse13200.00
3762543141497None002Supplying heavy gauge PVC Conduit Pipe ….dia .mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary.25mm dia 2mm thickMtr79.079.0200.0FalseNoneNoneFalseNoneFalse15800.00
3762544141497None003Supplying and fixing PVC/metal conduit Deep junction box 25mm deep junction boxMtr56.056.010.0FalseNoneNoneFalseNoneFalse560.00
3762545141497None004Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete 10"x7"x3" (254x178x76mm)Each112.0112.010.0FalseNoneNoneFalseNoneFalse1120.00
3762546141497None005Supplying And Fixing Metal Fan Box with Round Hook.Nos160.0160.08.0FalseNoneNoneFalseNoneFalse1280.00
3762547141497None006Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Short point upto 3Mtr from tapping point to out let via switchPoint285.0285.010.0FalseNoneNoneFalseNoneFalse2850.00
3762548141497None007Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Medium point above 3Mtr upto 6Mtr from tapping point to out let via switchPoint394.0394.010.0FalseNoneNoneFalseNoneFalse3940.00
3762549141497None008Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Long point above 6Mtr upto 10Mtr from tapping point to out let via switchPoint570.0570.010.0FalseNoneNoneFalseNoneFalse5700.00
3762550141497None009Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS:8130-1984 and (Virgin) PVC insulation sheathed suitabl 3C X 1.5Sq.mmMtr72.072.0200.0FalseNoneNoneFalseNoneFalse14400.00
3762551141497None010Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS:8130-1984 and (Virgin) PVC insulation sheathed suitabl 4C X 1.5Sq.mmMtr94.094.0200.0FalseNoneNoneFalseNoneFalse18800.00
3762552141497None011Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6Amps 2 WayEach128.0128.010.0FalseNoneNoneFalseNoneFalse1280.00
3762553141497None012Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board.6Amps 2way SwitchNos70.070.010.0FalseNoneNoneFalseNoneFalse700.00
3762554141497None013Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.1 to 3 ModuleEach137.0137.020.0FalseNoneNoneFalseNoneFalse2740.00
3762555141497None014Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.6 ModuleEach175.0175.020.0FalseNoneNoneFalseNoneFalse3500.00
3762556141497None015Supplying and fixing hylum plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N.F. screws.Sq CM0.410.4110000.0FalseNoneNoneFalseNoneFalse4100.00
3762557141497None016Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system.Each3031.03031.08.0FalseNoneNoneFalseNoneFalse24248.00
3762558141497None017Fixing all types and all capacities of fluorescent / false ceiling/ spot light / CFL / LED fittings indoor on the wall / ceiling /rafters / girders using 23/0.0076” twin twisted PVC insulatedwires, required Nos of round blocks and clamps.Each122.0122.08.0FalseNoneNoneFalseNoneFalse976.00
3762559141497None018Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each315.0315.08.0FalseNoneNoneFalseNoneFalse2520.00
3762560141497None019Supplying and fixing regular MCB distribution boards on wall/ wood board / flush mounting using required clamps, bolts,nuts etc., with provision for fixing suitable type capacityMCB's single phase / 3 phase / single door with powdercoated painting. Made out of 14 SWG MS enclosure.Each3044.03044.01.0FalseNoneNoneFalseNoneFalse3044.00
17235266330000NoneNoneBuildingsConstruction Of Boys Toilet 02 Nos582527.32
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3762561141498None001Earth work in surface excavation by manual means for lowering & levelling the ground by chiselling and wedging in Hard rock for all works other than foundation & depth not exceeding 100 mm as per drawing and technical specifications, including setting out, barricading, caution lights, dressing of excavated surfaces, disposing off the excavated spalls/stuff & stacking the selected spall/ stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.Cum185.9185.95.02FalseNoneNoneFalseNoneFalse933.2180
3762562141498None002Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In all kinds of soils Depth upto 3 m.Cum107.1107.118.28FalseNoneNoneFalseNoneFalse1957.7880
3762563141498None003Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.314.44FalseNoneNoneFalseNoneFalse4033.0920
3762564141498None004Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates.Cum6288.456288.453.64FalseNoneNoneFalseNoneFalse22889.9580
3762565141498None005Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand).Cum5891.555891.5512.06FalseNoneNoneFalseNoneFalse71052.0930
3762566141498None006Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) STEP-2 (ABOVE GROUND LEVEL.Cum6708.456708.454.86FalseNoneNoneFalseNoneFalse32603.0670
3762567141498None007Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(The cost of steel reinforcement & formwork to be paid separately).Cum10885.510885.55.34FalseNoneNoneFalseNoneFalse58128.570
3762568141498None008Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(The cost of steel reinforcement & formwork to be paid separately).Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregatesCum6724.26724.24.378FalseNoneNoneFalseNoneFalse29438.54760
3762569141498None009Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.BuildingsKgs93929.8593929.850.32FalseNoneNoneFalseNoneFalse30057.5520
3762570141498None010Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Cum1375.51375.569.84FalseNoneNoneFalseNoneFalse96064.920
3762571141498None011Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:3 (1 cement : 3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum1053.151053.159.72FalseNoneNoneFalseNoneFalse10236.6180
3762572141498None012Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm267.75267.759.98FalseNoneNoneFalseNoneFalse2672.1450
3762573141498None013Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing omplete as per specifications and as per directions of Engineer-in-charge.Sqm366.45366.4562.04FalseNoneNoneFalseNoneFalse22734.5580
3762574141498None014Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm105.0105.08.52FalseNoneNoneFalseNoneFalse894.60
3762575141498None015Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm182.7182.74.36FalseNoneNoneFalseNoneFalse796.5720
3762576141498None016Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.m333.9333.94.3FalseNoneNoneFalseNoneFalse1435.770
3762577141498None017Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.Sqm2484.32484.33.16FalseNoneNoneFalseNoneFalse7850.3880
3762578141498None018Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:Each4458.04458.02.0FalseNoneNoneFalseNoneFalse8916.00
3762579141498None019Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern3 KG4458.34458.36.0FalseNoneNoneFalseNoneFalse26749.80
3762580141498None020Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps:Each3236.13236.12.0FalseNoneNoneFalseNoneFalse6472.20
3762581141498None021Crazy ceramic tile flooring, with under layer 12 mm thick cement mortar 1:4 (1cement: 4 coarse sand), with joints not exceeding 5 mm, including filling the gaps with ordinary cement mixture & mixing with synthetic polyester fibre, triangular in shape having specific gravity of 1.34 to 1.40, cross section size ranging from 10 to 40 micron & length upto 6 mm , mixing fibre @ 125 g per 50 kg of cement in cement mortar, including providing and mixing water proofing material in mortar @ 1 kg per 50 kg of cement, all complete as per direction of Engineer-in-charge.Sqm712.95712.9515.16FalseNoneNoneFalseNoneFalse10808.3220
3762582141498None022Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1461.61461.67.4FalseNoneNoneFalseNoneFalse10815.840
3762583141498None023Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.Each5030.555030.552.0FalseNoneNoneFalseNoneFalse10061.10
3762584141498None024Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Ltr9.459.452000.0FalseNoneNoneFalseNoneFalse18900.00
3762585141498None02525mm Normal gauge polythene bore pipesm56.756.724.0FalseNoneNoneFalseNoneFalse1360.80
3762586141498None026Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark For 20 mm dia GM (Copper alloy) Gate valvesEach932.4932.460.0FalseNoneNoneFalseNoneFalse55944.00
3762587141498None027Providing and fixing brass bib cock of approved quality :20 mm nominal boreNos320.25320.256.0FalseNoneNoneFalseNoneFalse1921.50
3762588141498None028Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm182.7182.766.4FalseNoneNoneFalseNoneFalse12131.280
3762589141498None029Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) 78, solar reflection 0.70 and initial emittance 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner as per direction of incharge.Sqm1475.31475.316.72FalseNoneNoneFalseNoneFalse24667.0160
17235266330000NoneNoneBuildingsFor Electrification Work50220.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3762590141499None001Concealed Conduit System Supplying heavy gauge PVC conduit pipe 19 mm dia 2 mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wirewherever necessary 19/20 mm dia 2 mm thick (SR Item No.1.2.1 Page No.1 of 47 of PWD ELECTRICAL Vol-6 for 2023-24Common SOR)m66.066.040.0FalseNoneNoneFalseNoneFalse2640.00
3762591141499None002Concealed Conduit System Supplying heavy gauge PVC Conduit Pipe 19/20 dia 2 mmthick with suitable size bends, metal junction boxes adhesivepaste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface andrun with 18 SWG GI fish wire run throughout the conduit wherever necessary.19/20 mm dia 2 mm thick (SR Item No.1.3.1 Page No.1 of 47 of PWD ELECTRICAL Vol-6 for 2023-24Common SOR)m68.068.040.0FalseNoneNoneFalseNoneFalse2720.00
3762592141499None003Point wiring using Copper wire with switch : Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch ( SR Item No.2.1.1 Page No.5 of 47 of PWD ELECTRICAL Vol-6 for 2023-24Common SOR)Point285.0285.012.0FalseNoneNoneFalseNoneFalse3420.00
3762593141499None004Point wiring using Copper wire with switch : Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch (SR Item No.2.1.2 Page No.5 of 47 of PWD ELECTRICAL Vol-6 for 2023-24Common SOR)Point394.0394.04.0FalseNoneNoneFalseNoneFalse1576.00
3762594141499None005Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. " A Group 1 to 3 Module ( SR Item No.3.5.1,Page No.8 of 47 of PWD ELECTRICAL Vol-6 for 2023-24Common SOR) Each161.0161.02.0FalseNoneNoneFalseNoneFalse322.00
3762595141499None006Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. " A Group 4 Module ( SR Item No.3.5.3 Page No.8 of 47 of PWD ELECTRICAL Vol-6 for 2023-24Common SOR)Each175.0175.02.0FalseNoneNoneFalseNoneFalse350.00
3762596141499None007Supplying and fixing superior quality modular switch mounting polycorbonate plate with necessary supporting back plate with required no's of machine screwes, bolts, nuts etc., complete on the existing metal/ PVC box. " A Group 8 Module( SR Item No.3.5.5 Page No.8 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Each284.0284.02.0FalseNoneNoneFalseNoneFalse568.00
3762597141499None008Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3 Way ( SR Item No.3.4.2 Page No.8 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Each159.0159.02.0FalseNoneNoneFalseNoneFalse318.00
3762598141499None009Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 Way ( SR Item No.3.4.3 Page No.8 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Each177.0177.02.0FalseNoneNoneFalseNoneFalse354.00
3762599141499None010Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ( SR Item No.3.4.5 Page No.5 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Each261.0261.02.0FalseNoneNoneFalseNoneFalse522.00
3762600141499None011Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.Group A Materials.1.5 sqmm ( SR Item No.2.3.2 Page No.3 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Mtr26.026.050.0FalseNoneNoneFalseNoneFalse1300.00
3762601141499None012Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.Group A Materials.2.5 sqmm (SR Item No.2.3.3 Page No.3 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Mtr42.042.040.0FalseNoneNoneFalseNoneFalse1680.00
3762602141499None013Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ( SR Item No.12.46 Page No.52 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)No63.063.08.0FalseNoneNoneFalseNoneFalse504.00
3762603141499None014Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. 1x 4 20 /22 w ( SR Item No.11.3.2 Page No.43 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Each690.0690.02.0FalseNoneNoneFalseNoneFalse1380.00
3762604141499None015Fixing all types and all capacities of fluorescent/false ceiling/spot light/CFL/LED fittings indoor on the wall/ceiling/rafters/girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps On wall/Ceiling/Rafter/Girders (SR Item No.13.7.1 Page No.56 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Each122.0122.02.0FalseNoneNoneFalseNoneFalse244.00
3762605141499None016Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and "C" Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity on 10 K and complete wiring as required confirming to IEC 60898 6-32 Amps SP (SR Item No. 5.18.1 Page No.17 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Each415.0415.02.0FalseNoneNoneFalseNoneFalse830.00
3762606141499None017Supplying and fixing regular MCB distribution boards on wall/wood board/flush mounting using required clamps, bolts, nuts etc. with provision for fixing suitable type capacity MCB's single phase/3 Phase/single door with powder coated painting. Made out of 14 SWG MS enclosure I- Single Door 4 Way SP & N (SR Item No. 5.19.2 Page No. 18 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Each1241.01241.02.0FalseNoneNoneFalseNoneFalse2482.00
3762607141499None018Supplying & fixing retrofit type-PL- LED Lamp 18-20 W LED linear source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80.The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to275 V. bTested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.(SR Item No. 11.3.2 Page No. 43 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Each690.0690.08.0FalseNoneNoneFalseNoneFalse5520.00
3762608141499None019Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A One Way Switch,(SR Item No.3.6.1,Page No 9 of 47,PWD Electrical Vol 6 for 2021-22 Common SOR)Each102.0102.020.0FalseNoneNoneFalseNoneFalse2040.00
3762609141499None020Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Three Way socket Switch,(SR Item No.3.6.2,Page No 9 of 47,PWD Electrical Vol 6 for 2021-22 Common SOR)Each171.0171.04.0FalseNoneNoneFalseNoneFalse684.00
3762610141499None021Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300mm)(SR No.6.2.1, Page No 30 of 47,KPTCL,ESCOMS PWD Electrical Vol 6 for 2022 -23 Common SOR)Each2969.02969.06.0FalseNoneNoneFalseNoneFalse17814.00
3762611141499None022Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.(SR No.13.14, Page No 58 of 47,KPTCL,ESCOMS PWD Electrical Vol 6 for 2021 -22 Common SOR)Each492.0492.06.0FalseNoneNoneFalseNoneFalse2952.00
17235266330000NoneNoneBuildingsConstruction Of Girls Toilet265311.26
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3762612141500None001Earth work in surface excavation by manual means for lowering & levelling the ground by chiselling and wedging in Hard rock for all works other than foundation & depth not exceeding 100 mm as per drawing and technical specifications, including setting out, barricading, caution lights, dressing of excavated surfaces, disposing off the excavated spalls/stuff & stacking the selected spall/ stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.Cum185.9185.92.51FalseNoneNoneFalseNoneFalse466.6090
3762613141500None002Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In all kinds of soils Depth upto 3 m.Cum107.1107.19.14FalseNoneNoneFalseNoneFalse978.8940
3762614141500None003Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.39.59FalseNoneNoneFalseNoneFalse2678.4870
3762615141500None004Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates.Cum6288.456288.450.9FalseNoneNoneFalseNoneFalse5659.6050
3762616141500None005Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand).Cum5891.555891.554.58FalseNoneNoneFalseNoneFalse26983.2990
3762617141500None006Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)STEP-2 (ABOVE GROUND LEVEL.Cum6708.456708.452.11FalseNoneNoneFalseNoneFalse14154.82950
3762618141500None007Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(The cost of steel reinforcement & formwork to be paid separately).Cum10885.510885.52.27FalseNoneNoneFalseNoneFalse24710.0850
3762619141500None008Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(The cost of steel reinforcement & formwork to be paid separately).Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregatesCum6724.26724.21.199FalseNoneNoneFalseNoneFalse8062.31580
3762620141500None009Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.BuildingsTonne93929.8593929.850.14FalseNoneNoneFalseNoneFalse13150.1790
3762621141500None010Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Cum1375.51375.533.48FalseNoneNoneFalseNoneFalse46051.740
3762622141500None011Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:3 (1 cement : 3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum1053.151053.155.94FalseNoneNoneFalseNoneFalse6255.7110
3762623141500None012Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm267.75267.754.99FalseNoneNoneFalseNoneFalse1336.07250
3762624141500None013Providing 15 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in- charge.Sqm366.45366.4523.37FalseNoneNoneFalseNoneFalse8563.93650
3762625141500None014Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm105.0105.04.99FalseNoneNoneFalseNoneFalse523.950
3762626141500None015Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.Sqm182.7182.74.99FalseNoneNoneFalseNoneFalse911.6730
3762627141500None016Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.m333.9333.95.7FalseNoneNoneFalseNoneFalse1903.230
3762628141500None017Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.Sqm2484.32484.31.58FalseNoneNoneFalseNoneFalse3925.1940
3762629141500None018Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:Each4458.04458.01.0FalseNoneNoneFalseNoneFalse4458.00
3762630141500None019Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps:Each3236.13236.11.0FalseNoneNoneFalseNoneFalse3236.10
3762631141500None020Crazy ceramic tile flooring, with under layer 12 mm thick cement mortar 1:4 (1cement: 4 coarse sand), with joints not exceeding 5 mm, including filling the gaps with ordinary cement mixture & mixing with synthetic polyester fibre, triangular in shape having specific gravity of 1.34 to 1.40, cross section size ranging from 10 to 40 micron & length upto 6 mm , mixing fibre @ 125 g per 50 kg of cement in cement mortar, including providing and mixing water proofing material in mortar @ 1 kg per 50 kg of cement, all complete as per direction of Engineer-in-charge.Sqm712.95712.956.12FalseNoneNoneFalseNoneFalse4363.2540
3762632141500None021Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1461.61461.617.33FalseNoneNoneFalseNoneFalse25329.5280
3762633141500None022Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.Each5030.555030.551.0FalseNoneNoneFalseNoneFalse5030.550
3762634141500None023Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Ltr9.459.451000.0FalseNoneNoneFalseNoneFalse9450.00
3762635141500None02425mm Normal gauge polythene bore pipesm56.756.712.0FalseNoneNoneFalseNoneFalse680.40
3762636141500None025Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 20 mm dia GM (Copper alloy) Gate valvesEach932.4932.430.0FalseNoneNoneFalseNoneFalse27972.00
3762637141500None026Providing and fixing brass bib cock of approved quality :20 mm nominal boreNo320.25320.253.0FalseNoneNoneFalseNoneFalse960.750
3762638141500None027Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm182.7182.728.36FalseNoneNoneFalseNoneFalse5181.3720
3762639141500None028Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) 78, solar reflection 0.70 and initial emittance 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner as per direction of inchargeSqm1475.31475.38.36FalseNoneNoneFalseNoneFalse12333.5080
17235266330000NoneNoneBuildingsFor Electrification Work25110.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3762640141501None001Concealed Conduit System Supplying heavy gauge PVC conduit pipe 19 mm dia 2 mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wirewherever necessary 19/20 mm dia 2 mm thick (SR Item No.1.2.1 Page No.1 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)m66.066.020.0FalseNoneNoneFalseNoneFalse1320.00
3762641141501None002Concealed Conduit System Supplying heavy gauge PVC Conduit Pipe 19/20 dia 2 mmthick with suitable size bends, metal junction boxes adhesivepaste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface andrun with 18 SWG GI fish wire run throughout the conduit wherever necessary.19/20 mm dia 2 mm thick (SR Item No.1.3.1 Page No.1 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)m68.068.020.0FalseNoneNoneFalseNoneFalse1360.00
3762642141501None003Point wiring using Copper wire with switch : Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch ( SR Item No.2.1.1 Page No.5 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Point285.0285.06.0FalseNoneNoneFalseNoneFalse1710.00
3762643141501None004Point wiring using Copper wire with switch : Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch (SR Item No.2.1.2 Page No.5 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Pond394.0394.02.0FalseNoneNoneFalseNoneFalse788.00
3762644141501None005Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. " A Group 1 to 3 Module ( SR Item No.3.5.1,Page No.8 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Each161.0161.01.0FalseNoneNoneFalseNoneFalse161.00
3762645141501None006Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. " A Group 4 Module ( SR Item No.3.5.3 Page No.8 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Each175.0175.01.0FalseNoneNoneFalseNoneFalse175.00
3762646141501None007Supplying and fixing superior quality modular switch mounting polycorbonate plate with necessary supporting back plate with required no's of machine screwes, bolts, nuts etc., complete on the existing metal/ PVC box. " A Group 8 Module( SR Item No.3.5.5 Page No.8 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Each284.0284.01.0FalseNoneNoneFalseNoneFalse284.00
3762647141501None008Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3 Way ( SR Item No.3.4.2 Page No.8 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Each159.0159.01.0FalseNoneNoneFalseNoneFalse159.00
3762648141501None009Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 Way ( SR Item No.3.4.3 Page No.8 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Each177.0177.01.0FalseNoneNoneFalseNoneFalse177.00
3762649141501None010Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ( SR Item No.3.4.5 Page No.5 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Each261.0261.01.0FalseNoneNoneFalseNoneFalse261.00
3762650141501None011Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.Group A Materials.1.5 sqmm ( SR Item No.2.3.2 Page No.3 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Mtr26.026.025.0FalseNoneNoneFalseNoneFalse650.00
3762651141501None012Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.Group A Materials.2.5 sqmm (SR Item No.2.3.3 Page No.3 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Mtr42.042.020.0FalseNoneNoneFalseNoneFalse840.00
3762652141501None013Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ( SR Item No.12.46 Page No.52 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Nos63.063.04.0FalseNoneNoneFalseNoneFalse252.00
3762653141501None014Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. 1x 4' - 20 /22 w ( SR Item No.11.3.2 Page No.43 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Each690.0690.01.0FalseNoneNoneFalseNoneFalse690.00
3762654141501None015Fixing all types and all capacities of fluorescent/false ceiling/spot light/CFL/LED fittings indoor on the wall/ceiling/rafters/girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps On wall/Ceiling/Rafter/Girders (SR Item No.13.7.1 Page No.56 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Each122.0122.01.0FalseNoneNoneFalseNoneFalse122.00
3762655141501None016Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and "C" Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity on 10 K and complete wiring as required confirming to IEC 60898 6-32 Amps SP (SR Item No. 5.18.1 Page No.17 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Each415.0415.01.0FalseNoneNoneFalseNoneFalse415.00
3762656141501None017Supplying and fixing regular MCB distribution boards on wall/wood board/flush mounting using required clamps, bolts, nuts etc. with provision for fixing suitable type capacity MCB's single phase/3 Phase/single door with powder coated painting. Made out of 14 SWG MS enclosure I- Single Door 4 Way SP & N (SR Item No. 5.19.2 Page No. 18 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Each1241.01241.01.0FalseNoneNoneFalseNoneFalse1241.00
3762657141501None018Supplying & fixing retrofit type-PL- LED Lamp 18-20 W LED linear source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80.The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to275 V. bTested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.(SR Item No. 11.3.2 Page No. 43 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Each690.0690.04.0FalseNoneNoneFalseNoneFalse2760.00
3762658141501None019Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A One Way Switch,(SR Item No.3.6.1,Page No 9 of 47,PWD Electrical Vol 6 for 2021-22Common SOR)Each102.0102.010.0FalseNoneNoneFalseNoneFalse1020.00
3762659141501None020Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Three Way socket Switch,(SR Item No.3.6.2,Page No 9 of 47,PWD Electrical Vol 6 for 2021-22 Common SOR)Each171.0171.02.0FalseNoneNoneFalseNoneFalse342.00
3762660141501None021Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300mm)(SR No.6.2.1, Page No 30 of 47,KPTCL,ESCOMS PWD Electrical Vol 6 for 2022 -23 Common SOR)Each2969.02969.03.0FalseNoneNoneFalseNoneFalse8907.00
3762661141501None022Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.(SR No.13.14, Page No 58 of 47,KPTCL,ESCOMS PWD Electrical Vol 6 for 2021 -22 Common SOR)Each492.0492.03.0FalseNoneNoneFalseNoneFalse1476.00
17235266330000NoneNoneBuildingsConstruction Of CWSN Toilet291263.95
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3762662141502None001Earth work in surface excavation by manual means for lowering & levelling the ground by chiselling and wedging in Hard rock for all works other than foundation & depth not exceeding 100 mm as per drawing and technical specifications, including setting out, barricading, caution lights, dressing of excavated surfaces, disposing off the excavated spalls/stuff & stacking the selected spall/ stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.Cum185.9185.92.51FalseNoneNoneFalseNoneFalse466.6090
3762663141502None002Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In all kinds of soils Depth upto 3 m.Cum107.1107.19.14FalseNoneNoneFalseNoneFalse978.8940
3762664141502None003Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum279.3279.37.22FalseNoneNoneFalseNoneFalse2016.5460
3762665141502None004Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates.Cum6288.456288.451.82FalseNoneNoneFalseNoneFalse11444.9790
3762666141502None005Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand).Cum5891.555891.556.03FalseNoneNoneFalseNoneFalse35526.04650
3762667141502None006Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) STEP-2 (ABOVE GROUND LEVEL.Cum6708.456708.452.43FalseNoneNoneFalseNoneFalse16301.53350
3762668141502None007Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(The cost of steel reinforcement & formwork to be paid separately).Cum10885.510885.52.67FalseNoneNoneFalseNoneFalse29064.2850
3762669141502None008Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(The cost of steel reinforcement & formwork to be paid separately).Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregatesCum6724.26724.22.189FalseNoneNoneFalseNoneFalse14719.27380
3762670141502None009Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.BuildingsKgs93929.8593929.850.16FalseNoneNoneFalseNoneFalse15028.7760
3762671141502None010Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Cum1375.51375.534.92FalseNoneNoneFalseNoneFalse48032.460
3762672141502None011Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in foundations and plinth in Cement mortar 1:3 (1 cement : 3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum1053.151053.154.86FalseNoneNoneFalseNoneFalse5118.3090
3762673141502None012Providing 12 mm cement plaster with cement mortar 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm267.75267.754.99FalseNoneNoneFalseNoneFalse1336.07250
3762674141502None013Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing omplete as per specifications and as per directions of Engineer-in-charge.5 Kgs366.45366.4531.02FalseNoneNoneFalseNoneFalse11367.2790
3762675141502None014Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm105.0105.04.26FalseNoneNoneFalseNoneFalse447.30
3762676141502None015Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm182.7182.72.18FalseNoneNoneFalseNoneFalse398.2860
3762677141502None016Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.m333.9333.92.15FalseNoneNoneFalseNoneFalse717.8850
3762678141502None017Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.Sqm2484.32484.31.58FalseNoneNoneFalseNoneFalse3925.1940
3762679141502None018Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:Each4458.34458.31.0FalseNoneNoneFalseNoneFalse4458.30
3762680141502None019Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cisternEach4458.34458.33.0FalseNoneNoneFalseNoneFalse13374.90
3762681141502None020Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps:Each3236.13236.11.0FalseNoneNoneFalseNoneFalse3236.10
3762682141502None021Crazy ceramic tile flooring, with under layer 12 mm thick cement mortar 1:4 (1cement: 4 coarse sand), with joints not exceeding 5 mm, including filling the gaps with ordinary cement mixture & mixing with synthetic polyester fibre, triangular in shape having specific gravity of 1.34 to 1.40, cross section size ranging from 10 to 40 micron & length upto 6 mm , mixing fibre @ 125 g per 50 kg of cement in cement mortar, including providing and mixing water proofing material in mortar @ 1 kg per 50 kg of cement, all complete as per direction of Engineer-in-charge.Sqm712.95712.957.58FalseNoneNoneFalseNoneFalse5404.1610
3762683141502None022Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications.Sqm1461.61461.63.7FalseNoneNoneFalseNoneFalse5407.920
3762684141502None023Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.Each5030.555030.551.0FalseNoneNoneFalseNoneFalse5030.550
3762685141502None024Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Ltr9.459.451000.0FalseNoneNoneFalseNoneFalse9450.00
3762686141502None02525mm Normal gauge polythene bore pipesm56.756.712.0FalseNoneNoneFalseNoneFalse680.40
3762687141502None026Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark For 20 mm dia GM (Copper alloy) Gate valvesEach932.4932.430.0FalseNoneNoneFalseNoneFalse27972.00
3762688141502None027Providing and fixing brass bib cock of approved quality :20 mm nominal boreNos320.25320.253.0FalseNoneNoneFalseNoneFalse960.750
3762689141502None028Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm182.7182.733.2FalseNoneNoneFalseNoneFalse6065.640
3762690141502None029Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) 78, solar reflection 0.70 and initial emittance 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner as per direction of inchargeSqm1475.31475.38.36FalseNoneNoneFalseNoneFalse12333.5080
17235266330000NoneNoneBuildingsFor Electrification Work25110.0
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3762691141503None001Concealed Conduit System Supplying heavy gauge PVC conduit pipe 19 mm dia 2 mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wirewherever necessary 19/20 mm dia 2 mm thick (SR Item No.1.2.1 Page No.1 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)m66.066.020.0FalseNoneNoneFalseNoneFalse1320.00
3762692141503None002Concealed Conduit System Supplying heavy gauge PVC Conduit Pipe 19/20 dia 2 mmthick with suitable size bends, metal junction boxes adhesivepaste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface andrun with 18 SWG GI fish wire run throughout the conduit wherever necessary.19/20 mm dia 2 mm thick (SR Item No.1.3.1 Page No.1 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)m68.068.020.0FalseNoneNoneFalseNoneFalse1360.00
3762693141503None003Point wiring using Copper wire with switch : Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch ( SR Item No.2.1.1 Page No.5 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Point285.0285.06.0FalseNoneNoneFalseNoneFalse1710.00
3762694141503None004Point wiring using Copper wire with switch : Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch (SR Item No.2.1.2 Page No.5 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) Point394.0394.02.0FalseNoneNoneFalseNoneFalse788.00
3762695141503None005Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. " A Group 1 to 3 Module ( SR Item No.3.5.1,Page No.8 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) Each161.0161.01.0FalseNoneNoneFalseNoneFalse161.00
3762696141503None006Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. " A Group 4 Module ( SR Item No.3.5.3 Page No.8 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Each175.0175.01.0FalseNoneNoneFalseNoneFalse175.00
3762697141503None007Supplying and fixing superior quality modular switch mounting polycorbonate plate with necessary supporting back plate with required no's of machine screwes, bolts, nuts etc., complete on the existing metal/ PVC box. " A Group 8 Module( SR Item No.3.5.5 Page No.8 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) Each284.0284.01.0FalseNoneNoneFalseNoneFalse284.00
3762698141503None008Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3 Way ( SR Item No.3.4.2 Page No.8 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Each159.0159.01.0FalseNoneNoneFalseNoneFalse159.00
3762699141503None009Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 Way ( SR Item No.3.4.3 Page No.8 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Each177.0177.01.0FalseNoneNoneFalseNoneFalse177.00
3762700141503None010Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way ( SR Item No.3.4.5 Page No.5 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Each261.0261.01.0FalseNoneNoneFalseNoneFalse261.00
3762701141503None011Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.Group A Materials.1.5 sqmm ( SR Item No.2.3.2 Page No.3 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Mtr26.026.025.0FalseNoneNoneFalseNoneFalse650.00
3762702141503None012Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.Group A Materials.2.5 sqmm (SR Item No.2.3.3 Page No.3 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Mtr42.042.020.0FalseNoneNoneFalseNoneFalse840.00
3762703141503None013Supplying & Fixing of 70-150 Watts lamp holder 2 Pin ( SR Item No.12.46 Page No.52 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)No63.063.04.0FalseNoneNoneFalseNoneFalse252.00
3762704141503None014Supplying of .feet - PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. 1x 4' - 20 /22 w ( SR Item No.11.3.2 Page No.43 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR) Each690.0690.01.0FalseNoneNoneFalseNoneFalse690.00
3762705141503None015Fixing all types and all capacities of fluorescent/false ceiling/spot light/CFL/LED fittings indoor on the wall/ceiling/rafters/girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps On wall/Ceiling/Rafter/Girders (SR Item No.13.7.1 Page No.56 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Each122.0122.01.0FalseNoneNoneFalseNoneFalse122.00
3762706141503None016Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and "C" Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity on 10 K and complete wiring as required confirming to IEC 60898 6-32 Amps SP (SR Item No. 5.18.1 Page No.17 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Each415.0415.01.0FalseNoneNoneFalseNoneFalse415.00
3762707141503None017Supplying and fixing regular MCB distribution boards on wall/wood board/flush mounting using required clamps, bolts, nuts etc. with provision for fixing suitable type capacity MCB's single phase/3 Phase/single door with powder coated painting. Made out of 14 SWG MS enclosure I- Single Door 4 Way SP & N (SR Item No. 5.19.2 Page No. 18 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Each1241.01241.01.0FalseNoneNoneFalseNoneFalse1241.00
3762708141503None018Supplying & fixing retrofit type-PL- LED Lamp 18-20 W LED linear source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80.The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to275 V. bTested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.(SR Item No. 11.3.2 Page No. 43 of 47 of PWD ELECTRICAL Vol-6 for 2023-24 Common SOR)Each690.0690.04.0FalseNoneNoneFalseNoneFalse2760.00
3762709141503None019Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A One Way Switch,(SR Item No.3.6.1,Page No 9 of 47,PWD Electrical Vol 6 for 2021-22Common SOR)Each102.0102.010.0FalseNoneNoneFalseNoneFalse1020.00
3762710141503None020Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Three Way socket Switch,(SR Item No.3.6.2,Page No 9 of 47,PWD Electrical Vol 6 for 2021-22 Common SOR)Each171.0171.02.0FalseNoneNoneFalseNoneFalse342.00
3762711141503None021Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300mm)(SR No.6.2.1, Page No 30 of 47,KPTCL,ESCOMS PWD Electrical Vol 6 for 2022 -23 Common SOR)Each2969.02969.03.0FalseNoneNoneFalseNoneFalse8907.00
3762712141503None022Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.(SR No.13.14, Page No 58 of 47,KPTCL,ESCOMS PWD Electrical Vol 6 for 2021 -22 Common SOR)Each492.0492.03.0FalseNoneNoneFalseNoneFalse1476.00
17235266330000NoneNoneBuildingsFor Water Supply Works113181.6
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3762713141504None001Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the workRmtr508.2508.2108.0FalseNoneNoneFalseNoneFalse54885.60
3762714141504None002Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 75mm dia., 6 kg/sqcm & class 3Rmtr231.0231.0200.0FalseNoneNoneFalseNoneFalse46200.00
3762715141504None003Refilling available earth around trenches/ pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m, and lift upto 1.5 m. Including cost of all labour complete as per specificationCum168.0168.072.0FalseNoneNoneFalseNoneFalse12096.00
17235266330000NoneNoneBuildingsFor Water Supply Work14531.14
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3762716141505None001Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Ltr9.459.451000.0FalseNoneNoneFalseNoneFalse9450.00
3762717141505None002Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 25 mm nominal dia Pipes 25 mm nominal dia PipesRmtr365.55365.5513.9FalseNoneNoneFalseNoneFalse5081.1450
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17235266340000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17235266340000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17235266340000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17235266340000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17235266340000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17235270760000NoneNoneELIGIBILITYQualifications of the tenderer required as mentioned in the Technical Bid KW-4 in General conditions 3 must be furnished.None
17235270890000NoneNoneELIGIBILITYTender of the contractor, who have not completed the work in time, not executed the agreement in time in any other cases in this Division as per Clause 3.4 of Standard Tender Document and practices as mentioned in clause 25 of the standard tender document will not be accepted.None
17235270940000NoneNoneELIGIBILITYThe undersigned reserves the right to accept any or all tenders without assigning any reason.None
17235270980000NoneNoneELIGIBILITYContractor should execute the work by procuring cement, steel any other materials/Machinery for the work on their own and necessary quality test certificate should be produced and approval of the same.None
17235271040000NoneNoneELIGIBILITYOther details can be seen in the tender documentsNone
17235271090000NoneNoneELIGIBILITYContractors should have to upload the Scan copy of all necessary Qualification Documents/ Certificates, and submitted duly attested by notary while tender Evaluvation in this DivisionNone
17235271140000NoneNoneELIGIBILITYThe Department is not responsible for any delay in accessing e-procurement portal.None
17235271590000NoneNoneELIGIBILITYTenderer shall note that the Tenders of those found Eligible as mentioned in Clause 3 Qualification of Instructions to Tenders (ITT), will only be considered for evaluation.None
17235271650000NoneNoneELIGIBILITYContractors should have to upload the necessary Qualification details as Section 3 Clause 1.1 to 1.10 in prescribed formats of KW-4.None
17235271700000NoneNoneELIGIBILITYThe contractor should counter check all the designs of the scheme before execution / procurement of material and bring to the notice of the departmental officers for rectification.None
17235271740000NoneNoneELIGIBILITYThe contractors have to verify the designs and drawings prepared by the department and supplied for construction. correct the same for any mistakes and to submit it for the approval of the department prior to commencement of execution.None
17235271790000NoneNoneELIGIBILITYThe contractor should furnish the Contractor license CertificateNone
17235271850000NoneNoneELIGIBILITYSuccessful bidder submitting bids below the amount put to tender will be regularized to submit the difference amount in the form of FDR/TDR/DD/Pledge on the name of EE PRED Raichur within 20 days from the date of receiving the letter of acceptance. Failing which EMD will be forfeited and further action will be taken as per G O No FD PCL 2008 Bangalore Dated 14/10/2008. Cluase 25 of KW-4.None
17235271900000NoneNoneELIGIBILITYThe Building constructed under this programme shall be of high standard, requiring no major repairs for 3 years, The contractor shall furnish performance guarantee for 3 years as per clause and the performance guarantee will be released only after 3 years after completion of work.None
17235271950000NoneNoneELIGIBILITYThe Tenderer shall obtain the workdone certificate in the prescribed form from the competent authority not below the rank of Executive Engineer (District Level Officer) and scan the Original Certificate and attach the scanned file to the Bid. The Original Certificate / Certificates shall be produced whenever required.None
17235272000000NoneNoneELIGIBILITYThird party inspection is mandatory for all the works in this programmeNone
17235272040000NoneNoneELIGIBILITYThe work should be completed within the stipulated period from the date of agreement & The date of agreement itself is the date of commencement of the workNone
17235272120000NoneNoneELIGIBILITYThe work should be completed in 9 months (including mansoon)None
17235272170000NoneNoneELIGIBILITYThe defect liability period is 2 years and 3 years for major construction repairs.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. 200.32 Lakhs)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneSatisfactorily completed as prime contractor at-least one such similar work of value not less than Rs. 50.08 LakhsPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (1. Earthwork & Constn of Embankment : 550.13 Cum 2) PCC/RCC : 191.83 Cum 3) Steel : 12.79 Tone 4) SSM/BBM : 430.17 Cum, 5) Flooring : 296.32 Sqm, 6) Plastering : 1204.96 Sqm)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTenderer or his identifiedCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. 33.38 LakhsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
PWD Contractor Registration CertificateTrueTechnical Bid
Previous Five years Financial Turn over 2019-20 to 2023-24TrueTechnical Bid
Similar nature Work done CertificateTrueTechnical Bid
Quantity wise Work done certificateTrueTechnical Bid
Line of credit Bank letter headTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1724744868000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Executive Engineer, P.R.E.Divisioin, Beside District Court Complex, Arab Mohalla, RAICHUR
streetNone
cityRaichur
stateKarnataka
pin584101
tenderRecallDTONone