createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1725337952310
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee920.00
emd91475.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose12-09-2024 16:30:00
tenderQueryClose10-09-2024 16:30:00
technicalBidOpen13-09-2024 17:00:00
publishedDate03-09-2024 17:26:09
publishedByPostRDPR_EE_DIV_KRN
publishedByUserKPE18448 - S LAKSHMIKANTH
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonDhanalakshmi K S
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9972961399
tenderSupplierListNone
tenderSchedule
createdTs1725337952347
version12
createdDateNone
modifiedDateNone
tenderNumberRDPR/2024-25/BD/WORK_INDENT8382
titleConstruction of pair Residential Quatresses at Kaggundi Plant field for Sub-Sector Forest P.patna Social Forestry.
descriptionConstruction of pair Residential Quatresses at Kaggundi Plant field for Sub-Sector Forest P.patna Social Forestry.
categoryWORKS
categoryTextWorks
ecv3659000.00
deptNameRural Development and Panchayat Raj Department
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location974
locationNameRDPR Division Office K R Nagara
provisionalAmount3659000.0
groupOverheadTotal603465.73
fileNumberRDPR-FOREST/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17253379520000NoneNoneBuildingsConstruction of pair Residential Quatresses at Kaggundi Plant field for Sub-Sector Forest P.patna Social Forestry.3055534.27
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3905455150566None001Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work ( P.NO. 8, I.No. 1.14.1,Volume No-1)2023-24Cum102.0102.053.0FalseNoneNoneFalseNoneFalse5406.00
3905456150566None002Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to omplete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates (P.No.15, I.No.2.1.3) (Volume No-1) 2023-24Cum5989.05989.08.96FalseNoneNoneFalseNoneFalse53661.440
3905457150566None003Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (P.No.84, I.No. 11.32, Volume No-2) 2023-24Kg / Kgs83.083.01146.27FalseNoneNoneFalseNoneFalse95140.410
3905458150566None004Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)(P.No.16, I.No.2.5.1,Volume No -1, (2023-24) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Including CenteringCum6828.96828.95.58FalseNoneNoneFalseNoneFalse38105.2620
3905459150566None005Providing Coursed rubble masonry (Second sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (P.No. 9, I.NO. 5.3,Volume No-2) 2023-24Cum6205.06205.013.69FalseNoneNoneFalseNoneFalse84946.450
3905460150566None006Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (P.NO. 9, I.NO. 5.2, Volume No-2) 2023-24Cum6618.06618.010.15FalseNoneNoneFalseNoneFalse67172.70
3905461150566None007Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (P.No.84, I.No. 11.32, Volume No-2) 2023-24Kg / Kgs83.083.0358.88FalseNoneNoneFalseNoneFalse29787.040
3905462150566None008Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)(P.No.16, I.No.2.5.1,Volume No -1, (2023-24) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11271.011271.01.99FalseNoneNoneFalseNoneFalse22429.290
3905463150566None009Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)(P.No.16, I.No.2.5.1,Volume No -1, (2023-24) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum9945.09945.05.32FalseNoneNoneFalseNoneFalse52907.40
3905464150566None010Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (P.No.7, I.No. 1.9, Volume No-1)Cum266.0266.047.34FalseNoneNoneFalseNoneFalse12592.440
3905465150566None011Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)(P.No.16, I.No.2.5.1,Volume No -1, (2023-24) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11271.011271.03.73FalseNoneNoneFalseNoneFalse42040.830
3905466150566None012Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (P.NO.17, I.No. 6.32) (Volume No-2) 2023-24Cum1310.01310.096.74FalseNoneNoneFalseNoneFalse126729.40
3905467150566None013Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (P.No.84, I.No. 11.32, Volume No-2) 2023-24Kg / Kgs83.083.0289.0FalseNoneNoneFalseNoneFalse23987.00
3905468150566None014Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)(P.No.16, I.No.2.5.1,Volume No -1, (2023-24) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10608.010608.01.74FalseNoneNoneFalseNoneFalse18457.920
3905469150566None015Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)(P.No.16, I.No.2.5.1,Volume No -1, (2023-24) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesSqm9613.59613.50.79FalseNoneNoneFalseNoneFalse7594.6650
3905470150566None016Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (P.NO.17, I.No. 6.32) (Volume No-2) 2023-24Cum1310.01310.040.3FalseNoneNoneFalseNoneFalse52793.00
3905471150566None017Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (P.No.84, I.No. 11.32, Volume No-2) 2023-24Kgs83.083.01404.41FalseNoneNoneFalseNoneFalse116566.030
3905472150566None018Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)(P.No.16, I.No.2.5.1,Volume No -1, (2023-24) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10608.010608.06.67FalseNoneNoneFalseNoneFalse70755.360
3905473150566None019Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)(P.No.16, I.No.2.5.1,Volume No -1, (2023-24) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum9945.09945.011.73FalseNoneNoneFalseNoneFalse116654.850
3905474150566None020Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin-Charge. (P.No.84, I.No.11.26.3) (Volume No-2) 2023-24Kgs183.0183.0150.0FalseNoneNoneFalseNoneFalse27450.00
3905475150566None021Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (P.NO.17, I.No. 6.32) (Volume No-2) 2023-24Cum1310.01310.099.52FalseNoneNoneFalseNoneFalse130371.20
3905476150566None022Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (P.No.84, I.No. 11.32, Volume No-2) 2023-24Kgs83.083.0398.11FalseNoneNoneFalseNoneFalse33043.130
3905477150566None023Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)(P.No.16, I.No.2.5.1,Volume No -1, (2023-24) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11271.011271.03.73FalseNoneNoneFalseNoneFalse42040.830
3905478150566None024Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (P.No.84, I.No. 11.32, Volume No-2) 2023-24Kgs83.083.0289.0FalseNoneNoneFalseNoneFalse23987.00
3905479150566None025Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)(P.No.16, I.No.2.5.1,Volume No -1, (2023-24) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10608.010608.01.74FalseNoneNoneFalseNoneFalse18457.920
3905480150566None026Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)(P.No.16, I.No.2.5.1,Volume No -1, (2023-24) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesSqm9613.59613.50.79FalseNoneNoneFalseNoneFalse7594.6650
3905481150566None027Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (P.NO.17, I.No. 6.32) (Volume No-2) 2023-24Cum1310.01310.040.3FalseNoneNoneFalseNoneFalse52793.00
3905482150566None028Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (P.No.84, I.No. 11.32, Volume No-2) 2023-24Kgs83.083.01364.92FalseNoneNoneFalseNoneFalse113288.360
3905483150566None029Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)(P.No.16, I.No.2.5.1,Volume No -1, (2023-24) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10608.010608.03.7FalseNoneNoneFalseNoneFalse39249.60
3905484150566None030Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)(P.No.16, I.No.2.5.1,Volume No -1, (2023-24) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum9945.09945.011.28FalseNoneNoneFalseNoneFalse112179.60
3905485150566None031Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates (P.No.15, I.No.2.1.6, Volume No-1) 2023-24Cum6243.06243.03.42FalseNoneNoneFalseNoneFalse21351.060
3905486150566None032Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (P.NO.17, I.No. 6.32) (Volume No-2) 2023-24Cum1231.01231.025.5FalseNoneNoneFalseNoneFalse31390.50
3905487150566None033Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.(P.No.99, I.No. 12.12, Volume No-2) 2023-24Cum124202.0124202.01.127FalseNoneNoneFalseNoneFalse139975.6540
3905488150566Nonecode034Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications.Sqm6897.06897.016.64FalseNoneNoneFalseNoneFalse114766.080
3905489150566None035Providing and fixing in position Mathi/Nandi wood fully panelled shutters for windows with stiles and rails of 35mm. thick, 75mm wide in two halves with panels of 25mm thick including cost of materials, labour charges, usage charges complete as per specifications. (excluding cost of fixtures) (P.No.101, I.No.12.24, Volume No-2) 2023-24Sqm7013.07013.022.14FalseNoneNoneFalseNoneFalse155267.820
3905490150566None036Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. (P.No.86, I.No.11.34B Volume-2)2023-24Kgs183.0183.0332.1FalseNoneNoneFalseNoneFalse60774.30
3905491150566None037Cudddapah slab 2.5cms thick( P.No. A-19, I.No.261,) (Volume No-2) 2023-24Sqm462.0462.09.6FalseNoneNoneFalseNoneFalse4435.20
3905492150566None038Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (P.No.42, I.No.8.5.2, Volume No-2)2023-24Sqm349.0349.0594.14FalseNoneNoneFalseNoneFalse207354.860
3905493150566None039Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (P.No.42, I.No.8.8, Volume No-2) 2023-24Sqm371.0371.0282.77FalseNoneNoneFalseNoneFalse104907.670
3905494150566None040Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete Size of Tile 600x600 mm (P.No.61, I.No. 9.17.2 Volume No-2) 2023-24Sqm1175.01175.0109.69FalseNoneNoneFalseNoneFalse128885.750
3905495150566None041Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (P.No.60, I.No.9.11, Volume No-2) 2023-24Sqm889.0889.022.22FalseNoneNoneFalseNoneFalse19753.580
3905496150566None042Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(P.No.45, I.No. 8.25 Volume No-2)2023-24Sqm137.0137.0594.14FalseNoneNoneFalseNoneFalse81397.180
3905497150566None043Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(P.No.46, I.No. 8.31 Volume-2) 2023-24Sqm178.0178.0282.77FalseNoneNoneFalseNoneFalse50333.060
3905498150566None044Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(P.No.46, I.No. 8.33.2 Volume-2) 2023-24Sqm138.0138.097.07FalseNoneNoneFalseNoneFalse13395.660
3905499150566None045Providing and fixing vitreous china dual purpose closet suitable for use as squatting pan or European type water closet (Anglo Indian W.C pan) with seat & lid fixed with C.P. brass hinges and rubber buffers, 10 litre low level flushing cistern with fitting and brackets, 40 mm flush bend, 20 mm over flow pipe, with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : White vitreous china dual purpose WC pan with white solid plastic seat and lid with white vitreous china flushing cistern and C.P. flush bend. (P.No.137, I.No.14.35.1, Volume No-2) 2023-24Each8632.08632.02.0FalseNoneNoneFalseNoneFalse17264.00
3905500150566None046Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per anufacturers specification & direction of Engineer-in-charge. ( P. No.104, I. No.12.54, Volume No-2)2023-24Sqm318.0318.02.7FalseNoneNoneFalseNoneFalse858.60
3905501150566None047Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. ( P. No.104, I. No.12.55.2, Volume No-2)2023-24Sqm2040.02040.02.7FalseNoneNoneFalseNoneFalse5508.00
3905502150566None048Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1101.6 (P.No.146, I.No.16.15(a)) (Volume No-3) 2023-24 1200mm DiaRmtr8425.08425.03.6FalseNoneNoneFalseNoneFalse30330.00
3905503150566None049Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer (P.No.132, I.No.14.7.1 Volume No-2)2023-24Each3082.03082.02.0FalseNoneNoneFalseNoneFalse6164.00
3905504150566None050Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Semi rigid pipe 32 mm dia (P.No.136, I.No.14.28.1 Volume No-2)2023-24Each76.076.02.0FalseNoneNoneFalseNoneFalse152.00
3905505150566None051Providing and fixing brass bib cock of approved quality : 15 mm Dia nominal bore (P.No.117, I.No.13.2.1 Volume No-2)2023-24Each286.0286.06.0FalseNoneNoneFalseNoneFalse1716.00
3905506150566None052Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete :15 mm nominal bore (P.No.117, I.No.13.5.1 Volume No-2) 2023-24Each296.0296.02.0FalseNoneNoneFalseNoneFalse592.00
3905507150566None053Providing and fixing gun metal non- return valve of approved quality (screwed end) :25 mm nominal bore Horizontal (P.No.117, I.No.13.6.1 Volume No-2)2023-24Each620.0620.02.0FalseNoneNoneFalseNoneFalse1240.00
3905508150566None054Providing and installing at site of work PVC pipes including cost of pipes and specials and labour, including lowering into trenches, laying true to line, level and perfect linking at joints leak proof including jionting of approved type with all labour and lift charge, handling encasing the pipe all round to a depth not lessthan 15cms with gravel or selected earth available from the excavation etc., complete (PHE SR P.No.14, I.No.3.4.1)Rmtr124.63124.6360.0FalseNoneNoneFalseNoneFalse7477.80
3905509150566None055Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (P.No.123, I.No.13.34)Ltr9.09.01000.0FalseNoneNoneFalseNoneFalse9000.00
3905510150566None056Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall . 20 mm nominal dia Pipes( P.No. 122, I.No.13.31.2, Volume No-2) 2023-24Mtr242.0242.070.0FalseNoneNoneFalseNoneFalse16940.00
3905511150566None057Cost of Atlanta/Suguna/CRI/Kirloskar/Other qualent Pumps 1.0HP/0.075, 10Stage(P-XLIII I-I)Nos14924.014924.01.0FalseNoneNoneFalseNoneFalse14924.00
3905512150566None058ELECTRIFICATION-Supplying heavy gauge PVC conduit pipe ……mm dia .mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia Pipe. 2mm thick (P-2 / 1.2.2)Mtr80.3480.34210.0FalseNoneNoneFalseNoneFalse16871.40
3905513150566None059Supplying hevay gaguge PVC conduct pipe 25mm dia 2mm thick with suitable size bend metal junction box adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit whereever necessary (P.No.2, I.No.1.3.2)Mtr81.3781.3775.0FalseNoneNoneFalseNoneFalse6102.750
3905514150566None060Supplying and fixing Metal fan Box with Round Hook (P.No4, I.No.1.13)Nos120.51120.516.0FalseNoneNoneFalseNoneFalse723.060
3905515150566None061Supplying and flush mounting powder coated/galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after groove cutting in brick/stone/CC wall (a)1-3Way (P.No.8, I.No.3.4.2)Each163.77163.777.0FalseNoneNoneFalseNoneFalse1146.390
3905516150566None062Supplying and flush mounting powder coated/galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after groove cutting in brick/stone/CC wall b)10-12 WayEach328.57328.578.0FalseNoneNoneFalseNoneFalse2628.560
3905517150566None063Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. (a) 1-3 Module (P.No.8)Each165.83165.837.0FalseNoneNoneFalseNoneFalse1160.810
3905518150566None064Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.(b)10-12 ModuleEach354.32354.328.0FalseNoneNoneFalseNoneFalse2834.560
3905519150566None065Supplying and wiring adopting loop system. In existing PVC conduit/casing using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 Sqmm Cable confirming to the GTP with 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box the other end of the wires shall be terminated with sufficient loses length in a wood/PVC round block complete. for each outlet, (a) Short point above 3mtrs From tapping point to out let via switch.(P.No.5, I.No.2.2.1)Point277.07277.0714.0FalseNoneNoneFalseNoneFalse3878.980
3905520150566None066Supplying and wiring adopting loop system. In existing PVC conduit/casing using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 Sqmm Cable confirming to the GTP with 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box the other end of the wires shall be terminated with sufficient loses length in a wood/PVC round block complete. for each outlet, b) Mediumt point (P.No.5, I.No. 2.2.2)Point390.37390.3726.0FalseNoneNoneFalseNoneFalse10149.620
3905521150566None067Supplying and wiring adopting loop system. In existing PVC conduit/casing using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 Sqmm Cable confirming to the GTP with 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box the other end of the wires shall be terminated with sufficient loses length in a wood/PVC round block complete. for each outlet, Long point (P.No.5, I.No. 2.2.3)Point571.65571.658.0FalseNoneNoneFalseNoneFalse4573.20
3905522150566None068Wiring for lighting / power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS -694:1990 & confirming to GTP of Group - A .,(P.No.5 I.No. 2.3.1) (a)1.00SqmmMtr19.5719.57270.0FalseNoneNoneFalseNoneFalse5283.90
3905523150566None069Wiring for lighting / power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS -694:1990 & confirming to GTP of Group - A .,(P.No.5 I.No. 2.3.1) (b) 1.50Sqmm (P.No.5 I.No. 2.3.2)Mtr26.7826.78540.0FalseNoneNoneFalseNoneFalse14461.20
3905524150566None070Wiring for lighting / power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS -694:1990 & confirming to GTP of Group - A .,(P.No.5 I.No. 2.3.1) c) 2.50 Sqmm (P.No.5 I.No. 2.3.2)Mtr43.2643.26110.0FalseNoneNoneFalseNoneFalse4758.60
3905525150566None071Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(P.No.9, I.No.3.6.1) (a) 6A One Way SwitchNos105.06105.0658.0FalseNoneNoneFalseNoneFalse6093.480
3905526150566None072Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(P.No.9, I.No.3.6.1) (b) 6 Two Way Switch (P.No.9, I.No.3.6.2)Nos170.98170.982.0FalseNoneNoneFalseNoneFalse341.960
3905527150566None073Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(P.No.9, I.No.3.6.1) (c) 6 Three Way Switch (P.No.9, I.No.3.6.3)Nos176.13176.1310.0FalseNoneNoneFalseNoneFalse1761.30
3905528150566None074Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.(P.No.9, I.No.3.6.1 (d) Stepped Fan regulator Two ModuleNos367.71367.716.0FalseNoneNoneFalseNoneFalse2206.260
3905529150566None075Supplying and fixing LED Bulk head of 10 W with IP-65 Protection and IK-08 Impact resistance suitable for surfacew and wall mounting application (P.No.46, I.No.11.15)Each867.26867.262.0FalseNoneNoneFalseNoneFalse1734.520
3905530150566None076Supplying of . feet - LED Batten. W with high quality diffuser with life of 25000 burning hours and 70% lumen maintenance with CRI 80 power input 220-240V @ 50Hz and Power factor 0.90 along with CE approved 2years warranty against any manufactureing defect working under standard electrical condition LED Light fitting 1X4' 20/22W (P.No.43, I.No.11.3.2)Each710.7710.710.0FalseNoneNoneFalseNoneFalse7107.00
3905531150566None077Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles.Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system 48" Sweep(P.No.30, I.No.6.3.1)Each3073.523073.526.0FalseNoneNoneFalseNoneFalse18441.120
3905532150566None078Fixing all type and all capacities fluorescent/false ceiling/spot light/CFL/LED fittings indoor on the wall/ceiling /rafters/girders using 23/0.0076" twin twisted PVC insulated wires required nos of round blocks and clamps (if required)(P.No.56 I.No.143.1)Each125.66125.6610.0FalseNoneNoneFalseNoneFalse1256.60
3905533150566None079Fixing a ceiling/ wall mounting fan of all capacities and all types necessary clamps and S hook made out of 165mm dia MS rod, with 5 Amps ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted copper wire and wiring (P.No. 57 I.No. 13.10)Each176.13176.136.0FalseNoneNoneFalseNoneFalse1056.780
3905534150566None080Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. single door 4Way SP & N (P.No.18, I.No.5.18.3)Each1278.231278.232.0FalseNoneNoneFalseNoneFalse2556.460
3905535150566None081Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 Amps DP(P.No.17, I.No.5.18.4)Each761.17761.172.0FalseNoneNoneFalseNoneFalse1522.340
3905536150566None082Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14SWG P.No. 21, I.No.5.42.2)Sq CM0.440.448000.0FalseNoneNoneFalseNoneFalse3520.00
3905537150566None083Supplying fixing and wiring Electronic Trivector Meter (ETV) 5 to 20Amps single pahase class-1 Accuracy with Temper Proof Energy Meter(P.No.19, I.No.5.30)Each1421.41421.42.0FalseNoneNoneFalseNoneFalse2842.80
3905538150566None084Supplying and fixing of Porcelain fuse channel with cut out on existing wooden/pannel using necessary nuts bolts and washers (a) 32Amps (P.No.14, I.No.5.7.1)Each161.71161.712.0FalseNoneNoneFalseNoneFalse323.420
3905539150566None085Supplying of 1.1 KV LTUG cable XLPE or Heat resistant PVC insulated PVC extruded Inner sheath armound UGLT cable as per IS-1554 (Part-1) or IS-7098 Part-1 Armounting strip thickness in average +5% and resistivity 14 Ohms/Kms (max) as per IS-3975 2Core 10 SqmmMtr81.6181.6170.0FalseNoneNoneFalseNoneFalse5712.70
3905540150566None086Earth eork excavation for cable trench of 0.5 to 075mtr width and depth upto 1.00mtr including trial pit depositing on bank upto a lead of 50mtr Supplying and dispalying necessary Danger board and lighting using sit rails and sign boards at every 100 mtrs wherever necessary In Hard SoilCum307.97307.9735.0FalseNoneNoneFalseNoneFalse10778.950
3905541150566None087Labour charges for laying of 1.1KV class UG cable when supplied agency in existing trench GI pipe / stone ware pipe on wall on pole as required in existing trench duct 6 sqm to 16sqm(P.No.174, I.No.21.05) existing trenchMtr21.521.570.0FalseNoneNoneFalseNoneFalse1505.00
3905542150566None088Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers.(P.No.70, I.No.7.22)Mtr20.0920.0920.0FalseNoneNoneFalseNoneFalse401.80
3905543150566None089Supplying fixing and wiring earth electrodes for grounding conduit I.C cutouts and other equipments on the ,meter board using 40mm dia 2.90mm thick GI pipes 2.50m long birred in pit, the pit should be filled with equal proportion of charcoal and salt 150mm all-round the pipe to complete depth. The connection from the pipe to the conduct etc ., is to be established through GI wire of size as per IS specification 7.3.3 of IS732 using 12mm dia bolts , nuts, washers and check nuts etc., the pipe shell have 16 through holes of 12mm dia.(P.No.54, I.No.12.56)Each3615.33615.34.0FalseNoneNoneFalseNoneFalse14461.20
3905544150566None090Chescom DepositNo13000.013000.01.0FalseNoneNoneFalseNoneFalse13000.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17253379530000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17253379530000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17253379530000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17253379530000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17253379530000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17253379690000NoneNoneELIGIBILITYDepartment Registration DetailsNone
17253379820000NoneNoneELIGIBILITYList of existing commitments and ongoing work .None
17253380130000NoneNoneELIGIBILITYWithin 21 days of receipt of Letter of Acceptance, the successful Tenderer shall deliver to the employer a Security Deposit in the form of NSC/DD/ FDR in favour of the Executive Engineer, P.R.E. Division, K R Nagar, for an amount equivalent to 5 percent of the Contract price plus additional security for unbalanced tenders in accordance with the conditions of contract for General Category.None
17253380270000NoneNoneELIGIBILITYConditional tenders will not be accepted .None
17253380500000NoneNoneELIGIBILITYAs per Karnataka State Government order No. LD/300/LET/2006 Bangalore Dated 01.01.2007 and Government Letter No.PW/134/ BMS/2007 Dated 27-7-2007, a sum amounting to 1% of the bill amount will be deducted towards Construction Labour Welfare fund. The tenderer shall abide by the directions of Government towards recovery as modifed by the Government from time to time .None
17253380610000NoneNoneELIGIBILITYAll safety precautions, warnings, signs, deployment of security guards have to be ensured so that no un towards incident happens on account of negligence or any project activity .None
17253380720000NoneNoneELIGIBILITYAll materials required for the work, shall be procured by the tenderer himself and should be got tested by the Department quality control authorities at his own cost before use for the work. If employer wishes to engage third party inspecting agency for the said work, apart from the quality control authorities, then the contractor should cooperate with the third party for test .None
17253380890000NoneNoneELIGIBILITYIn the case of death of the contractor after executing the agreement/ commencement of the work, his legal heir, if is an eligible registered contractor and is willing, can execute and complete the work at the accepted tender rates in the same terms and condition of the contractor of the work.None
17253381130000NoneNoneELIGIBILITYThe tenderers are requested to abide instructions and conditions 2 of 33 KPPP-Portal contained in the Standard Tender Documents K/W-1 and further orders thereon .None
17253381270000NoneNoneELIGIBILITYSite investigation report. The tenderer before applying this tender has to visit the site along with Junior Engineer/Assistant Engineer/ Assistant Executive Engineer of PERIYAPATNA sub-Division and submit feasibility report to know the nature of work and working condition.None
17253381390000NoneNoneELIGIBILITYThe tenderer are Requested to Refer this Notification For More Imformation And fallow The condition.None
17253381530000NoneNoneELIGIBILITYGST Shall be Paid Seperately.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneProposals for subcontracting components of works amounting to more than 20% of the contract price (for each, the qualifications and experience of the identified sub-contractor in the relevant fields should be attached)NoneNone
NoneNoneNoneNoneWork Done Certificate Tenderer in his name should have satisfactorily completed as a prime contractor for at least one similar work for the KW 2 works of Sl. No.10 of this notification Improvement,or Constructions of buildings. value not less than 50 percent Rs 18.30 Lakh of the amount put to tender in any one of the last five financial year period 2019-20, 2020-21, 2021-22, 2022-23 and 2023-24 should be obtained from not below the rank of Executive Engineer,Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneAnnual Turnover Certificate in all classes of Civil Engineering works only for last Five Financial years ie., 2019-20, 2020-21, 2021-22 ,2022-23,and 2023-24 Certified from Charted Accountant with compulsory UDI number Profit and Loss, balance sheet shall be enclosed .Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneAnnual turnover certificate in all classes of civil engineering construction works only for least five financial years i.e. 2019-20, 2020-21, 2021-22, 2022-23 and 2023-24 obtained from the Competent authority Charted Accountant/Auditor.The tenderer must have achieved in at last one financial years of Last Five Financial Years an annual financial turnover not less than The amount put to tender Rs 36.59 Lakhs. Certificate should be in the prescribed form as in KW 2 Section 3 3.2aFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneSubmission of K Form liquid assets /availability of credit facilities of not less than Rs 11.00 Lakhs Credit lines/ letter of credit certificates from Nationalized bank for meeting the fund requirement as per KW-2Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNonePWD Contractor Civil Registration Certificate class 4 and aboveOthersTechnical
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate in all classes of Civil Engineering works only for last Five Financial years ie., 2019-20, 2020-21, 2021-22 ,2022-23,and 2023-24 Certified from Charted Accountant with compulsory UDI number Profit and Loss, balance sheet shall be enclosedTrueTechnical Bid
Submission of K Form liquid assets /availability of credit facilities of not less than Rs 11.00 Lakhs Credit lines/ letter of credit certificates from Nationalized bank for meeting the fund requirement as per KW-2TrueTechnical Bid
PWD Contractor Civil Registration Certificate class 4 and aboveTrueTechnical Bid
Work Done Certificate Tenderer in his name should have satisfactorily completed as a prime contractor for at least one similar work for the KW 2 works of Sl. No.10 of this notification Improvement,or Constructions of buildings. value not less than 50 percent Rs 18.30 Lakh of the amount put to tender in any one of the last five financial year period 2019-20, 2020-21, 2021-22, 2022-23 and 2023-24 should be obtained from not below the rank of Executive Engineer,TrueTechnical Bid
Annual turnover certificate in all classes of civil engineering construction works only for least five financial years i.e. 2019-20, 2020-21, 2021-22, 2022-23 and 2023-24 obtained from the Competent authority Charted Accountant/Auditor.The tenderer must have achieved in at last one financial years of Last Five Financial Years an annual financial turnover not less than The amount put to tender Rs 36.59 Lakhs. Certificate should be in the prescribed form as in KW 2 Section 3 3.2aTrueTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone