3907537 | 150689 | None | code01 | Earth work in surface excavation by mechanical means for lowering &leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth & with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 95.0 | 95.0 | 95.85 | False | None | None | False | None | False | 9105.75 | 0 |
3907538 | 150689 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils. Depth upto 1.50m ( & with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 102.0 | 102.0 | 161.21 | False | None | None | False | None | False | 16443.42 | 0 |
3907539 | 150689 | None | code03 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipe sand conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. ( & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 118.0 | 118.0 | 660.85 | False | None | None | False | None | False | 77980.3 | 0 |
3907540 | 150689 | None | code04 | KSRB 2.8 : Providing and Filling in foundation with granite / trap broken metal 100mm. and down size, with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift. complete as per specifications. s & with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 2429.0 | 2429.0 | 4.17 | False | None | None | False | None | False | 10128.93 | 0 |
3907541 | 150689 | None | code05 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8 (M5) Using 40 mm nominal size graded crushed coarse aggregates & with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 5664.0 | 5664.0 | 59.56 | False | None | None | False | None | False | 337347.84 | 0 |
3907542 | 150689 | None | code06 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) & with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 6389.0 | 6389.0 | 82.45 | False | None | None | False | None | False | 526773.05 | 0 |
3907543 | 150689 | None | code07 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. & with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 266.0 | 266.0 | 364.61 | False | None | None | False | None | False | 96986.26 | 0 |
3907544 | 150689 | None | code08 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. & with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 6217.0 | 6217.0 | 20.93 | False | None | None | False | None | False | 130121.81 | 0 |
3907545 | 150689 | None | code09 | Providing and laying in Cement Concrete for all Basement & surface level
works, return walls, retaining walls, sunken floors etc. The granite/trap/
basalt crushed graded coarse aggregates and fine aggregates as per relevant
IS Codes machine mixed with super plasticisers, laid in layers, well compacted
using needle vibrators, providing weep holes wherever necessary, including all
lead & lifts, cost of all materials of quality, labour, Usage charges of machinery,
curing and all other appurtenances required to complete the work as per
technical specifications.& with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 6480.0 | 6480.0 | 31.61 | False | None | None | False | None | False | 204832.8 | 0 |
3907546 | 150689 | None | code10 | Form Charges for Footing Charges & with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 518.4 | 518.4 | 18.64 | False | None | None | False | None | False | 9662.976 | 0 |
3907547 | 150689 | None | code11 | Form Charges for Columns& with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 4536.0 | 4536.0 | 3.78 | False | None | None | False | None | False | 17146.08 | 0 |
3907548 | 150689 | None | code12 | Form Charges for Plinth & with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 3240.0 | 3240.0 | 9.19 | False | None | None | False | None | False | 29775.6 | 0 |
3907549 | 150689 | None | code13 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes alllead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates & with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 6843.0 | 6843.0 | 70.44 | False | None | None | False | None | False | 482020.92 | 0 |
3907550 | 150689 | None | code14 | Form Charges for Columns & with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 4790.1 | 4790.1 | 9.51 | False | None | None | False | None | False | 45553.851 | 0 |
3907551 | 150689 | None | code15 | Form Charges for Lintel & Beam & with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 4105.8 | 4105.8 | 17.5 | False | None | None | False | None | False | 71851.5 | 0 |
3907552 | 150689 | None | code16 | Form Charges for chajja & with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 3079.35 | 3079.35 | 0.54 | False | None | None | False | None | False | 1662.849 | 0 |
3907553 | 150689 | None | code17 | Form Charges for Roof & with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 3421.5 | 3421.5 | 42.88 | False | None | None | False | None | False | 146713.92 | 0 |
3907554 | 150689 | None | code18 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Buildings & with all lead and lift. and as per direction of the Engineer in charge of work. | t | 89457.0 | 89457.0 | 10.6 | False | None | None | False | None | False | 948244.2 | 0 |
3907555 | 150689 | None | code19 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 1231.0 | 1231.0 | 237.21 | False | None | None | False | None | False | 292005.51 | 0 |
3907556 | 150689 | None | code20 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. & with all lead and lift. and as per direction of the Engineer in charge of work. | Kg | 183.0 | 183.0 | 453.6 | False | None | None | False | None | False | 83008.8 | 0 |
3907557 | 150689 | None | code21 | Providing & fixing of 2-track x 2panel sliding windows made out of multi chambered UPVC(Matching to RAL9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 22.5 mm. Maximum possible size 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 5390.0 | 5390.0 | 21.6 | False | None | None | False | None | False | 116424.0 | 0 |
3907558 | 150689 | None | code22 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete andside clamps ), but including cost of materials, labour, usage charges complete as per specifications. & with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 75344.0 | 75344.0 | 0.43 | False | None | None | False | None | False | 32397.92 | 0 |
3907559 | 150689 | None | code23 | Providing and fixing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures) & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 4556.0 | 4556.0 | 20.16 | False | None | None | False | None | False | 91848.96 | 0 |
3907560 | 150689 | None | code24 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 333.0 | 333.0 | 445.12 | False | None | None | False | None | False | 148224.96 | 0 |
3907561 | 150689 | None | code25 | Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer in-charge | Sqm | 323.0 | 323.0 | 268.77 | False | None | None | False | None | False | 86812.71 | 0 |
3907562 | 150689 | None | code26 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge & with all lead and lift. and as per direction of the Engineer in charge of work. & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 241.0 | 241.0 | 293.28 | False | None | None | False | None | False | 70680.48 | 0 |
3907563 | 150689 | None | code27 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 2852.0 | 2852.0 | 175.49 | False | None | None | False | None | False | 500497.48 | 0 |
3907564 | 150689 | None | code28 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. .Size of Tile 600x600 mm & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 1082.0 | 1082.0 | 131.22 | False | None | None | False | None | False | 141980.04 | 0 |
3907565 | 150689 | None | code29 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 100.0 | 100.0 | 562.05 | False | None | None | False | None | False | 56205.0 | 0 |
3907566 | 150689 | None | code30 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 174.0 | 174.0 | 445.12 | False | None | None | False | None | False | 77450.88 | 0 |
3907567 | 150689 | None | code31 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 174.0 | 174.0 | 562.05 | False | None | None | False | None | False | 97796.7 | 0 |
3907568 | 150689 | None | code32 | Providing and fixing mosquito mesh to mesh to windows with 7.5 mm to 1.25 mm thick Honne wood petties including labour charges etc., complete. & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 715.0 | 715.0 | 21.6 | False | None | None | False | None | False | 15444.0 | 0 |
3907569 | 150689 | None | code33 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 167.0 | 167.0 | 93.96 | False | None | None | False | None | False | 15691.32 | 0 |
3907570 | 150689 | None | code34 | Sl.No. 432, Code No. 0137 Enamel metal paint & with all lead and lift. and as per direction of the Engineer in charge of work. | l | 207.63 | 207.63 | 10.0 | False | None | None | False | None | False | 2076.3 | 0 |
3907571 | 150689 | None | code35 | Painter Class -1 | No | 514.28 | 514.28 | 5.0 | False | None | None | False | None | False | 2571.4 | 0 |
3907572 | 150689 | None | code36 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. .. & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 565.0 | 565.0 | 88.0 | False | None | None | False | None | False | 49720.0 | 0 |
3907573 | 150689 | None | code37 | Providing wall black boards in CM 1:3 with two coats of black paint including finishing etc., complete & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 781.0 | 781.0 | 8.0 | False | None | None | False | None | False | 6248.0 | 0 |
3907574 | 150689 | None | code38 | Anodised Aluminium butt hinges 100x75x4 mm & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 393.0 | 393.0 | 1.6 | False | None | None | False | None | False | 628.8 | 0 |
3907575 | 150689 | None | code39 | Oxidised mild steel tower bolt (barrel type) 250x10 mm & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 55.0 | 55.0 | 30.0 | False | None | None | False | None | False | 1650.0 | 0 |
3907576 | 150689 | None | code40 | KSRB 8.6-7 : Providing and fixing on wall face un plasticised rigid PVC rain water pipes confirming to IS :13592Type A including joiting with seal ring confirming to IS :5382, leaving 10mm gap thermal expansion [i] single socketed pipes 100mm diameter & with all lead and lift. and as per direction of the Engineer in charge of work. | Mtr | 253.0 | 253.0 | 80.0 | False | None | None | False | None | False | 20240.0 | 0 |
3907577 | 150689 | None | code41 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 817.0 | 817.0 | 276.58 | False | None | None | False | None | False | 225965.86 | 0 |
3907578 | 150689 | None | code42 | Table
1'' Square tube 18 guage frame construction and two no's lockers instead one side and wooden top instead & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 8000.0 | 8000.0 | 4.0 | False | None | None | False | None | False | 32000.0 | 0 |
3907579 | 150689 | None | code43 | Kacheri Chairs
PU handle I pipe with Powder Coated good quality bushes inside sheet back spring and absolutly with fabric & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 6500.0 | 6500.0 | 4.0 | False | None | None | False | None | False | 26000.0 | 0 |
3907580 | 150689 | None | code44 | Lakars Alamara
1'' Square tube 18 guage frame construction and two no's lockers instead one side and wooden top instead & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 25000.0 | 25000.0 | 4.0 | False | None | None | False | None | False | 100000.0 | 0 |
3907581 | 150689 | None | code45 | School Desk 6 ft, CR pipe-25x25mm, bottom 16 guage pipe. Top 18 guage pipe, bottom pipe size 25x50mm CR pipe with back rest and pre laminated board 18mm with wood beading frame fully powder coated & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 6990.0 | 6990.0 | 35.0 | False | None | None | False | None | False | 244650.0 | 0 |
3907582 | 150689 | None | code46 | Supplying heavy gauge PVC conduit pipe mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary
19/20 mm dia 2 mm thick & with all lead and lift. and as per direction of the Engineer in charge of work. | Mtr | 61.0 | 61.0 | 140.0 | False | None | None | False | None | False | 8540.0 | 0 |
3907583 | 150689 | None | code47 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary 19/20 mm dia 2 mm thick19/20 mm dia 2 mm thick & with all lead and lift. and as per direction of the Engineer in charge of work. | Mtr | 75.0 | 75.0 | 140.0 | False | None | None | False | None | False | 10500.0 | 0 |
3907584 | 150689 | None | code48 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc135 x 75 x 65 mm & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 262.0 | 262.0 | 5.0 | False | None | None | False | None | False | 1310.0 | 0 |
3907585 | 150689 | None | code49 | Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.(200 x 200 x 65 mm & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 335.0 | 335.0 | 5.0 | False | None | None | False | None | False | 1675.0 | 0 |
3907586 | 150689 | None | code50 | Supplying and fixing PVC/metal conduit Deep junction box - 32 mm deep Junction box (Vol-6, Part-I, P.No. 1, I.No. 1.5.3) & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 69.0 | 69.0 | 10.0 | False | None | None | False | None | False | 690.0 | 0 |
3907587 | 150689 | None | code51 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3m from tapping point to out let via switch & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 276.0 | 276.0 | 125.0 | False | None | None | False | None | False | 34500.0 | 0 |
3907588 | 150689 | None | code52 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3m upto 6m from tapping point to out let
via switch & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 386.0 | 386.0 | 100.0 | False | None | None | False | None | False | 38600.0 | 0 |
3907589 | 150689 | None | code53 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6m upto 10m from tapping point to out let via
switch & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 567.0 | 567.0 | 100.0 | False | None | None | False | None | False | 56700.0 | 0 |
3907590 | 150689 | None | code54 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 122 mm dia & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 2727.0 | 2727.0 | 2.0 | False | None | None | False | None | False | 5454.0 | 0 |
3907591 | 150689 | None | code55 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 56" Sweep (1400mm)Regular model & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 2170.0 | 2170.0 | 8.0 | False | None | None | False | None | False | 17360.0 | 0 |
3907592 | 150689 | None | code56 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 80.0 | 80.0 | 8.0 | False | None | None | False | None | False | 640.0 | 0 |
3907593 | 150689 | None | code57 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers 32Amps & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 200.0 | 200.0 | 8.0 | False | None | None | False | None | False | 1600.0 | 0 |
3907594 | 150689 | None | code58 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps SP & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 523.0 | 523.0 | 8.0 | False | None | None | False | None | False | 4184.0 | 0 |
3907595 | 150689 | None | code59 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6Amps 3/5 Way & with all lead and lift. and as per direction of the Engineer in charge of work. & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 143.0 | 143.0 | 50.0 | False | None | None | False | None | False | 7150.0 | 0 |
3907596 | 150689 | None | code60 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 Way & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 250.0 | 250.0 | 25.0 | False | None | None | False | None | False | 6250.0 | 0 |
3907597 | 150689 | None | code61 | wiring for lighting / power circute using one of FRLS PVC insuleted 1100V grade , multistrand Copper conductor single core wire in open or concealed system of wiring as per IS 694-1990 & Confirming to GTP of Group -A2.5 sqmm & with all lead and lift. and as per direction of the Engineer in charge of work. | Mtr | 40.0 | 40.0 | 400.0 | False | None | None | False | None | False | 16000.0 | 0 |
3907598 | 150689 | None | code62 | wiring for lighting / power circute using one of FRLS PVC insuleted 1100V grade , multistrand Copper conductor single core wire in open or concealed system of wiring as per IS 694-1990 & Confirming to GTP of Group -A 4 sqmm & with all lead and lift. and as per direction of the Engineer in charge of work. | Mtr | 59.0 | 59.0 | 250.0 | False | None | None | False | None | False | 14750.0 | 0 |
3907599 | 150689 | None | code63 | Supply and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws. Bolts nuts etc.., complete on the existing metal/ PVC box1 to 3 Module & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 152.0 | 152.0 | 8.0 | False | None | None | False | None | False | 1216.0 | 0 |
3907600 | 150689 | None | code64 | Supply and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws. Bolts nuts etc.., complete on the existing metal/ PVC box4 Module & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 175.0 | 175.0 | 9.0 | False | None | None | False | None | False | 1575.0 | 0 |
3907601 | 150689 | None | code65 | Supply and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws. Bolts nuts etc.., complete on the existing metal/ PVC box6 Module & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 244.0 | 244.0 | 9.0 | False | None | None | False | None | False | 2196.0 | 0 |
3907602 | 150689 | None | code66 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 119.0 | 119.0 | 30.0 | False | None | None | False | None | False | 3570.0 | 0 |
3907603 | 150689 | None | code67 | Supplying and fixing 32mm dia Class A GI pipe bracket up to 2m long bent at suitable angle and fixing to this bracket lx40x2x40 watts fluoresecent tube street light fitting of all capacities to GI or CI or rail or RCC pole/ wall using suitable clamps, bolts and nuts and wiring using suitable capacity wires. Using 32mm dia GI Pipe & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 902.0 | 902.0 | 2.0 | False | None | None | False | None | False | 1804.0 | 0 |
3907604 | 150689 | None | code68 | Supplying and fixing 32Amps security and energy saving DP switch with key tag suitable to operate on 230 Volts, 50Hz AC supply & completely wired on existing box. & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 747.0 | 747.0 | 5.0 | False | None | None | False | None | False | 3735.0 | 0 |
3907605 | 150689 | None | code69 | Fixing charges of post top/ Gate/ Garden fitting /LED on the existing CI / GI or any other pipe using required size of reducer, wiring using suitable wires. & with all lead and lift. and as per direction of the Engineer in charge of work. | Mtr | 166.0 | 166.0 | 30.0 | False | None | None | False | None | False | 4980.0 | 0 |
3907606 | 150689 | None | code70 | Supplying, fixing and wiring electronic Trivector Mtere (ETV) 5 to 32/63 Amps three phase 4 wire current class-1 Accuracy Energy Meter. & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 5125.0 | 5125.0 | 1.0 | False | None | None | False | None | False | 5125.0 | 0 |
3907607 | 150689 | None | code71 | Dismantling weather proof course and removing and conveying the debris to a distance to the appropriate disposal area as per direction of Engineer-in-charge. & with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 576.0 | 576.0 | 19.68 | False | None | None | False | None | False | 11335.68 | 0 |
3907608 | 150689 | None | code72 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates with 20% partial replacement with Recycled concrete aggregate (RCA) & with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 6287.0 | 6287.0 | 13.12 | False | None | None | False | None | False | 82485.44 | 0 |
3907609 | 150689 | None | code73 | Providing two coats of water proof cement painting with approved colour and shade over one coat of primer including scaffolding & scrapping of old paint and stain with wire brushes and cleaning of paint stains etc., wherever necessary for old RCC over head tanks with all lead and lifts etc,. complete for: & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 164.0 | 164.0 | 489.89 | False | None | None | False | None | False | 80341.96 | 0 |
3907610 | 150689 | None | code74 | Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. 0.63 mm thick with zinc coating not less than 275 g/ m² & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 879.0 | 879.0 | 32.0 | False | None | None | False | None | False | 28128.0 | 0 |
3907611 | 150689 | None | code75 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. & with all lead and lift. and as per direction of the Engineer in charge of work. | Kg | 136.0 | 136.0 | 250.0 | False | None | None | False | None | False | 34000.0 | 0 |
3907612 | 150689 | None | code76 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 5664.0 | 5664.0 | 3.94 | False | None | None | False | None | False | 22316.16 | 0 |
3907613 | 150689 | None | code77 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates & with all lead and lift. and as per direction of the Engineer in charge of work. | Cum | 6287.0 | 6287.0 | 1.97 | False | None | None | False | None | False | 12385.39 | 0 |
3907614 | 150689 | None | code78 | Providing and fixing mosquito mesh to mesh to windows with 7.5 mm to 1.25 mm thick Honne wood petties including labour charges etc., complete. & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 715.0 | 715.0 | 18.0 | False | None | None | False | None | False | 12870.0 | 0 |
3907615 | 150689 | None | code79 | Anodised Aluminium butt hinges 100x75x4 mm & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 393.0 | 393.0 | 3.5 | False | None | None | False | None | False | 1375.5 | 0 |
3907616 | 150689 | None | code80 | Oxidised mild steel tower bolt (barrel type) 250x10 mm [P.No. A-29 Item No.583] & with all lead and lift. and as per direction of the Engineer in charge of work. | No | 55.0 | 55.0 | 35.0 | False | None | None | False | None | False | 1925.0 | 0 |
3907617 | 150689 | None | code81 | KSRB 8.6-7 : Providing and fixing on wall face un plasticised rigid PVC rain water pipes confirming to IS :13592Type A including joiting with seal ring confirming to IS :5382, leaving 10mm gap thermal expansion [i] single socketed pipes 100mm diameter & with all lead and lift. and as per direction of the Engineer in charge of work. | Mtr | 253.0 | 253.0 | 75.0 | False | None | None | False | None | False | 18975.0 | 0 |
3907618 | 150689 | None | code82 | Repair to plaster of thickness 12mm to 20 mm in patches of area 2.5 m² and under, including cutting the patch in proper shape, raking out joints and preparing plastering the wall surface with white cement based polymer modified self curing mortar, including disposal of rubbish, all complete as per the direction of Engineer-In-Charge. (For Roof and Water Tanks) (P-177,It-20.38)Vol -2 PWDSR 23-24 | Sqm | 518.0 | 518.0 | 52.01 | False | None | None | False | None | False | 26941.18 | 0 |
3907619 | 150689 | None | code83 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 137.0 | 137.0 | 1285.38 | False | None | None | False | None | False | 176097.06 | 0 |
3907620 | 150689 | None | code84 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 53.0 | 53.0 | 1509.67 | False | None | None | False | None | False | 80012.51 | 0 |
3907621 | 150689 | None | code85 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.. & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 89.0 | 89.0 | 1509.67 | False | None | None | False | None | False | 134360.63 | 0 |
3907622 | 150689 | None | code86 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. & with all lead and lift. and as per direction of the Engineer in charge of work. | Sqm | 115.0 | 115.0 | 308.91 | False | None | None | False | None | False | 35524.65 | 0 |