3807353 | 144565 | None | code01 | Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical pecifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.(KPWD 2023-24 Page No.27.Vol-1 I.no.1.1) | Sqm | 93.73 | 93.73 | 193.75 | False | None | None | False | None | False | 18160.1875 | 0 |
3807354 | 144565 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications,including setting out, shoring, strutting, barricading, caution lights,including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work-In ordinary/soft rock without blasting upto 1.5 m depth(Page No.08. Iitem no.1.15.1 of Vol-1-CSR-KPWD 2021-2022) | Cum | 373.89 | 373.89 | 128.98 | False | None | None | False | None | False | 48224.3322 | 0 |
3807355 | 144565 | None | code03 | Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work-In Hard Rock ( requiring blasting) Depth upto 1.50m(Page No.09. Iitem no.1.16.1 of Vol-1-CSR-KPWD 2021-2022) | Cum | 570.62 | 570.62 | 6.075 | False | None | None | False | None | False | 3466.5165 | 0 |
3807356 | 144565 | None | code04 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(Page No.07. Iitem no.1.9 of Vol-1-CSR-KPWD 2021-2022) | Cum | 273.98 | 273.98 | 109.5 | False | None | None | False | None | False | 30000.81 | 0 |
3807357 | 144565 | None | code05 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.(Page No.05. Iitem no.4.1 of Vol-2-CSR-KPWD 2021-2022) | Sqm | 121.54 | 121.54 | 212.7 | False | None | None | False | None | False | 25851.558 | 0 |
3807358 | 144565 | None | code06 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.(KPWD 2023-24 Page No.15.Vol-1 I.no.2.1.3) | Cum | 6168.67 | 6168.67 | 153.5525 | False | None | None | False | None | False | 947214.700175 | 0 |
3807359 | 144565 | None | code07 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)(PWD SR 2023-24 Vol:2 P.NO.09 I.No.5.4) | Cum | 6580.67 | 6580.67 | 143.8185 | False | None | None | False | None | False | 946422.088395 | 0 |
3807360 | 144565 | None | code08 | Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.(PWD SR 2023-24 Vol:1 P.NO.15 I.No.2.2.3). | Cum | 6526.08 | 6526.08 | 18.225 | False | None | None | False | None | False | 118937.808 | 0 |
3807361 | 144565 | None | code09 | Footings-For Centering & Shuttering @8% | Cum | 522.09 | 522.09 | 18.225 | False | None | None | False | None | False | 9515.09025 | 0 |
3807362 | 144565 | None | code10 | Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.(PWD SR 2023-24 Vol:1 P.NO.15 I.No.2.2.3) | Cum | 6526.08 | 6526.08 | 2.511 | False | None | None | False | None | False | 16386.98688 | 0 |
3807363 | 144565 | None | code11 | Pedastals -For Centering & Shuttering @5% | Cum | 326.3 | 326.3 | 2.511 | False | None | None | False | None | False | 819.3393 | 0 |
3807364 | 144565 | None | code12 | Providing and laying in cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.(PWD SR 2023-24 Vol:1 P.NO.16 I.No.2.3.2).- | Cum | 6674.4 | 6674.4 | 10.47 | False | None | None | False | None | False | 69880.968 | 0 |
3807365 | 144565 | None | code13 | Plinth Beam -For Centering & Shuttering @50% | Cum | 3337.2 | 3337.2 | 10.47 | False | None | None | False | None | False | 34940.484 | 0 |
3807366 | 144565 | None | code14 | Providing and laying in position cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.(PWD SR 2023-24 Vol:1 P.NO.15 I.No.2.2.3) | Cum | 6526.08 | 6526.08 | 2.4299 | False | None | None | False | None | False | 15857.721792 | 0 |
3807367 | 144565 | None | code15 | Columns Below Plinth-For Centering & Shuttering @70% | Cum | 4568.26 | 4568.26 | 2.4299 | False | None | None | False | None | False | 11100.414974 | 0 |
3807368 | 144565 | None | code16 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(PWD SR 2023-24 Vol:1 P.NO.16 I.No.2.5.2).- | Cum | 7048.29 | 7048.29 | 6.48 | False | None | None | False | None | False | 45672.9192 | 0 |
3807369 | 144565 | None | code17 | Ground Floor -Columns -For Centering & Shuttering @70% | Cum | 4933.8 | 4933.8 | 6.48 | False | None | None | False | None | False | 31971.024 | 0 |
3807370 | 144565 | None | code18 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(PWD SR 2023-24 Vol:1 P.NO.16 I.No.2.5.2). | Cum | 7116.72 | 7116.72 | 6.48 | False | None | None | False | None | False | 46116.3456 | 0 |
3807371 | 144565 | None | code19 | 1st Floor -Columns -For Centering & Shuttering @70% | Cum | 4981.7 | 4981.7 | 6.48 | False | None | None | False | None | False | 32281.416 | 0 |
3807372 | 144565 | None | code20 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(PWD SR 2023-24 Vol:1 P.NO.16 I.No.2.5.2).- | Cum | 7048.29 | 7048.29 | 12.705 | False | None | None | False | None | False | 89548.52445 | 0 |
3807373 | 144565 | None | code21 | Ground Floor - Lintel Side &Ground Floor -Beam sides-For Centering & Shuttering @60% | Cum | 4228.97 | 4228.97 | 12.705 | False | None | None | False | None | False | 53729.06385 | 0 |
3807374 | 144565 | None | code22 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(PWD SR 2023-24 Vol:1 P.NO.16 I.No.2.5.2).- | Cum | 7116.72 | 7116.72 | 12.705 | False | None | None | False | None | False | 90417.9276 | 0 |
3807375 | 144565 | None | code23 | 1st Floor - Lintel Side &Ground Floor -Beam sides-For Centering & Shuttering @60% | Cum | 4270.03 | 4270.03 | 12.705 | False | None | None | False | None | False | 54250.73115 | 0 |
3807376 | 144565 | None | code24 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(PWD SR 2023-24 Vol:1 P.NO.16 I.No.2.5.2). | Cum | 7048.29 | 7048.29 | 23.7 | False | None | None | False | None | False | 167044.473 | 0 |
3807377 | 144565 | None | code25 | Ground Floor Slab -For Centering & Shuttering @50% | Cum | 3524.15 | 3524.15 | 23.7 | False | None | None | False | None | False | 83522.355 | 0 |
3807378 | 144565 | None | code26 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(PWD SR 2023-24 Vol:1 P.NO.16 I.No.2.5.2).- | Cum | 7116.72 | 7116.72 | 27.0 | False | None | None | False | None | False | 192151.44 | 0 |
3807379 | 144565 | None | code27 | 1st Floor Slab -For Centering & Shuttering @50% | Cum | 3558.36 | 3558.36 | 27.0 | False | None | None | False | None | False | 96075.72 | 0 |
3807380 | 144565 | None | code28 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(PWD SR 2023-24 Vol:1 P.NO.16 I.No.2.5.2).- | Cum | 7048.29 | 7048.29 | 6.1717 | False | None | None | False | None | False | 43499.931393 | 0 |
3807381 | 144565 | None | code29 | Groun Floor -Chejja-For Centering & Shuttering @45% | Cum | 3171.73 | 3171.73 | 6.1717 | False | None | None | False | None | False | 19574.966041 | 0 |
3807382 | 144565 | None | code30 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(PWD SR 2023-24 Vol:1 P.NO.16 I.No.2.5.2).- | Cum | 7116.72 | 7116.72 | 6.6217 | False | None | None | False | None | False | 47124.784824 | 0 |
3807383 | 144565 | None | code31 | 1ST Floor -Chejja-For Centering & Shuttering @45% | Cum | 3202.52 | 3202.52 | 6.6217 | False | None | None | False | None | False | 21206.126684 | 0 |
3807384 | 144565 | None | code32 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(PWD SR 2023-24 Vol:1 P.NO.16 I.No.2.5.2).- | Cum | 7189.25 | 7189.25 | 5.3617 | False | None | None | False | None | False | 38546.601725 | 0 |
3807385 | 144565 | None | code33 | 2nd Floor -Staircase-For Centering & Shuttering @45% | Cum | 3235.16 | 3235.16 | 5.3617 | False | None | None | False | None | False | 17345.957372 | 0 |
3807386 | 144565 | None | code34 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification-Buildings-(PWD SR 2023-24 Vol:1 P.NO.18 I.No.2.11A) | Kg | 92140.71 | 92140.71 | 13.596 | False | None | None | False | None | False | 1252745.09316 | 0 |
3807387 | 144565 | None | code35 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(KPWD 2023-24 Page No.17.Vol-2 I.no.6.32 ) | Sqm | 1349.3 | 1349.3 | 312.9249 | False | None | None | False | None | False | 422229.56757 | 0 |
3807388 | 144565 | None | code36 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.(KPWD 2023-24 Page No.17.Vol-2 I.no.6.32 ) | Sqm | 1362.4 | 1362.4 | 282.955 | False | None | None | False | None | False | 385497.892 | 0 |
3807389 | 144565 | None | code37 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications(KPWD 2023-24 Page No.17.Vol-2 I.no.6.33 ) | Sqm | 1267.93 | 1267.93 | 14.49 | False | None | None | False | None | False | 18372.3057 | 0 |
3807390 | 144565 | None | code38 | Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(KPWD 2023-24 Page No.41.Vol-2 I.no.8.4.2) | Sqm | 321.36 | 321.36 | 492.9249 | False | None | None | False | None | False | 158406.345864 | 0 |
3807391 | 144565 | None | code39 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement:4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(KPWD 2023-24 Page No.42.Vol-2 I.no.8.5.2) | Sqm | 359.47 | 359.47 | 254.75 | False | None | None | False | None | False | 91574.9825 | 0 |
3807392 | 144565 | None | code40 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.(KPWD 2023-24 Page No.63.Vol-2 I.no.9.24) | Sqm | 2937.56 | 2937.56 | 484.0 | False | None | None | False | None | False | 1421779.04 | 0 |
3807393 | 144565 | None | code41 | In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tile)(KPWD 2023-24 Page No.60.Vol-2 I.no.9.7.2) | Sqm | 1297.8 | 1297.8 | 325.0 | False | None | None | False | None | False | 421785.0 | 0 |
3807394 | 144565 | None | code42 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.(KPWD 2023-24 Page No.64.Vol-2 I.no.9.30) | Sqm | 5487.84 | 5487.84 | 19.71 | False | None | None | False | None | False | 108165.3264 | 0 |
3807395 | 144565 | None | code43 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete.(KPWD 2023-24 Page No.60.Vol-2 I.no.9.9) | Sqm | 1108.28 | 1108.28 | 34.944 | False | None | None | False | None | False | 38727.73632 | 0 |
3807396 | 144565 | None | code44 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(KPWD 2023-24 Page No.45.Vol-2 I.no.8.29) | Sqm | 291.49 | 291.49 | 254.75 | False | None | None | False | None | False | 74257.0775 | 0 |
3807397 | 144565 | None | code45 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(KPWD 2023-24 Page No.50.Vol-2 I.no.8.51) | Sqm | 103.0 | 103.0 | 492.9249 | False | None | None | False | None | False | 50771.2647 | 0 |
3807398 | 144565 | None | code46 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(KPWD 2023-24 Page No.48.Vol-2 I.no.8.39) | Sqm | 130.81 | 130.81 | 492.9249 | False | None | None | False | None | False | 64479.506169 | 0 |
3807399 | 144565 | None | code47 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.(KPWD 2023-24 Page No.99.Vol-2 I.no-12.11) | Cum | 142216.22 | 142216.22 | 0.0772 | False | None | None | False | None | False | 10979.092184 | 0 |
3807400 | 144565 | None | code48 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.(KPWD 2023-24 Page No.99.Vol-2 I.no-12.11) | Cum | 143596.96 | 143596.96 | 0.0772 | False | None | None | False | None | False | 11085.685312 | 0 |
3807401 | 144565 | None | code49 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 30 mm thick Both side teak(KPWD 2023-24 Page No.105.Vol-2 I.no-12.57.1) | Sqm | 4164.29 | 4164.29 | 4.2 | False | None | None | False | None | False | 17490.018 | 0 |
3807402 | 144565 | None | code50 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification.-do- 30 mm thick Both side teak(KPWD 2023-24 Page No.105.Vol-2 I.no-12.57.1) | Sqm | 4204.72 | 4204.72 | 4.2 | False | None | None | False | None | False | 17659.824 | 0 |
3807403 | 144565 | None | code51 | Providing and fixing bright finished brass butt hinges with necessary screws
etc. complete :75x40x2.5 mm (ordinary type)(KPWD 2023-24 Page No.107.Vol-2 I.no-12.75.6) | Nos | 105.06 | 105.06 | 3.0 | False | None | None | False | None | False | 315.18 | 0 |
3807404 | 144565 | None | code52 | Providing and fixing bright finished brass butt hinges with necessary screws
etc. complete :75x40x2.5 mm (ordinary type)(KPWD 2023-24 Page No.107.Vol-2 I.no-12.75.6) | Nos | 106.08 | 106.08 | 3.0 | False | None | None | False | None | False | 318.24 | 0 |
3807405 | 144565 | None | code53 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :100x10mm(KPWD 2023-24 Page No.107.Vol-2 I.no-12.76.2) | Each | 360.5 | 360.5 | 3.0 | False | None | None | False | None | False | 1081.5 | 0 |
3807406 | 144565 | None | code54 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :100x10mm(KPWD 2023-24 Page No.107.Vol-2 I.no-12.76.2) | Each | 364.0 | 364.0 | 3.0 | False | None | None | False | None | False | 1092.0 | 0 |
3807407 | 144565 | None | code55 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :200x10mm(KPWD 2023-24 Page No.107.Vol-2 I.no-12.76.4) | Each | 202.91 | 202.91 | 3.0 | False | None | None | False | None | False | 608.73 | 0 |
3807408 | 144565 | None | code56 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :200x10mm(KPWD 2023-24 Page No.107.Vol-2 I.no-12.76.4) | Each | 204.88 | 204.88 | 3.0 | False | None | None | False | None | False | 614.64 | 0 |
3807409 | 144565 | None | code57 | Providing and fixing chromium plated brass night latch of approved quality
including necessary screws etc. complete.(KPWD 2023-24 Page No.105.Vol-2 I.no-12.61) | Each | 1019.7 | 1019.7 | 1.0 | False | None | None | False | None | False | 1019.7 | 0 |
3807410 | 144565 | None | code58 | Providing and fixing chromium plated brass night latch of approved quality
including necessary screws etc. complete.(KPWD 2023-24 Page No.105.Vol-2 I.no-12.61) | Each | 1029.6 | 1029.6 | 1.0 | False | None | None | False | None | False | 1029.6 | 0 |
3807411 | 144565 | None | code59 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.(KPWD 2023-24 Page No.105.Vol-2 I.no-12.60) | Nos | 1083.56 | 1083.56 | 1.0 | False | None | None | False | None | False | 1083.56 | 0 |
3807412 | 144565 | None | code60 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.(KPWD 2023-24 Page No.105.Vol-2 I.no-12.60) | Nos | 1094.08 | 1094.08 | 1.0 | False | None | None | False | None | False | 1094.08 | 0 |
3807413 | 144565 | None | code61 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete.(KPWD 2023-24 Page No.105.Vol-2 I.no-12.62) | Nos | 244.11 | 244.11 | 1.0 | False | None | None | False | None | False | 244.11 | 0 |
3807414 | 144565 | None | code62 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete.(KPWD 2023-24 Page No.105.Vol-2 I.no-12.62) | Nos | 246.48 | 246.48 | 1.0 | False | None | None | False | None | False | 246.48 | 0 |
3807415 | 144565 | None | code63 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary
accessories and screws etc. complete.(KPWD 2023-24 Page No.105.Vol-2 I.no-12.59) | Nos | 1147.42 | 1147.42 | 1.0 | False | None | None | False | None | False | 1147.42 | 0 |
3807416 | 144565 | None | code64 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary
accessories and screws etc. complete.(KPWD 2023-24 Page No.105.Vol-2 I.no-12.59) | Nos | 1158.56 | 1158.56 | 1.0 | False | None | None | False | None | False | 1158.56 | 0 |
3807417 | 144565 | None | code65 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.(KPWD 2023-24 Page No.105.Vol-2 I.no-12.58) | Nos | 123.6 | 123.6 | 1.0 | False | None | None | False | None | False | 123.6 | 0 |
3807418 | 144565 | None | code66 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.(KPWD 2023-24 Page No.105.Vol-2 I.no-12.58) | Nos | 124.8 | 124.8 | 1.0 | False | None | None | False | None | False | 124.8 | 0 |
3807419 | 144565 | None | code67 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.(KPWD 2023-24 Page No.104.Vol-2 I.no-12.51) | Nos | 1046.48 | 1046.48 | 1.0 | False | None | None | False | None | False | 1046.48 | 0 |
3807420 | 144565 | None | code68 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.(KPWD 2023-24 Page No.104.Vol-2 I.no-12.51) | Nos | 1056.64 | 1056.64 | 1.0 | False | None | None | False | None | False | 1056.64 | 0 |
3807421 | 144565 | None | code69 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding(KPWD 2023-24 Page No.86.Vol-2 I.no-11.34A) | Kg | 173.04 | 173.04 | 194.4 | False | None | None | False | None | False | 33638.976 | 0 |
3807422 | 144565 | None | code70 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding(KPWD 2023-24 Page No.86.Vol-2 I.no-11.34A) | Kg | 174.72 | 174.72 | 336.96 | False | None | None | False | None | False | 58873.6512 | 0 |
3807423 | 144565 | None | code71 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and
lead free, gaskets -grey colour having isolated drainage and with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement
of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows
shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The
cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)(KPWD 2023-24 Page No.110.Vol-2 I.no-12.90) | Sqm | 6936.02 | 6936.02 | 9.0 | False | None | None | False | None | False | 62424.18 | 0 |
3807424 | 144565 | None | code72 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and
lead free, gaskets -grey colour having isolated drainage and with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement
of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows
shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The
cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)(KPWD 2023-24 Page No.110.Vol-2 I.no-12.90) | Sqm | 7003.36 | 7003.36 | 18.0 | False | None | None | False | None | False | 126060.48 | 0 |
3807425 | 144565 | None | code73 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free
with gaskets -grey colour having isolated drainage and with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness.
Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)(KPWD 2023-24 Page No.109.Vol-2 I.no-12.85) | Sqm | 5890.57 | 5890.57 | 1.799 | False | None | None | False | None | False | 10597.13543 | 0 |
3807426 | 144565 | None | code74 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free
with gaskets -grey colour having isolated drainage and with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness.
Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)(KPWD 2023-24 Page No.109.Vol-2 I.no-12.85) | Sqm | 5947.76 | 5947.76 | 0.72 | False | None | None | False | None | False | 4282.3872 | 0 |
3807427 | 144565 | None | code75 | Applying priming coat: With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(KPWD 2023-24 Page No.47.Vol-2 I.no-8.34.2) | Sqm | 59.74 | 59.74 | 4.2 | False | None | None | False | None | False | 250.908 | 0 |
3807428 | 144565 | None | code76 | Applying priming coat: With ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(KPWD 2023-24 Page No.47.Vol-2 I.no-8.34.2) | Sqm | 60.32 | 60.32 | 4.2 | False | None | None | False | None | False | 253.344 | 0 |
3807429 | 144565 | None | code77 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade
including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge(KPWD 2023-24 Page No.46.Vol-2 I.no-8.33.2) | Sqm | 142.14 | 142.14 | 4.2 | False | None | None | False | None | False | 596.988 | 0 |
3807430 | 144565 | None | code78 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade
including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge(KPWD 2023-24 Page No.46.Vol-2 I.no-8.33.2) | Sqm | 143.52 | 143.52 | 4.2 | False | None | None | False | None | False | 602.784 | 0 |
3807431 | 144565 | None | code79 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :New work (two coats) including a coat of approved steel primer but excluding a coat of
mordant solution including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge(KPWD 2023-24 Page No.48.Vol-2 I.no-8.37) | Sqm | 134.93 | 134.93 | 10.8 | False | None | None | False | None | False | 1457.244 | 0 |
3807432 | 144565 | None | code80 | Painting on G.S. sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :New work (two coats) including a coat of approved steel primer but excluding a coat of
mordant solution including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge(KPWD 2023-24 Page No.48.Vol-2 I.no-8.37) | Sqm | 136.24 | 136.24 | 18.72 | False | None | None | False | None | False | 2550.4128 | 0 |
3807433 | 144565 | None | code81 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as(KPWD 2023-24 Page No.85.Vol-2 I.no-11.28) | Kg | 581.95 | 581.95 | 180.0 | False | None | None | False | None | False | 104751.0 | 0 |
3807434 | 144565 | None | code82 | Loading and Unloading of Stone Boulder/Stone aggregates/Sand/Kankar/Moorum.(Tipper 5.5 m3).(PWD SR 2023-24 Vol:3 P.NO.5 I.No.1.1A) | Cum | 139.05 | 139.05 | 327.305 | False | None | None | False | None | False | 45511.76025 | 0 |
3807435 | 144565 | None | code83 | Open Conduit System SupplyingheavygaugePVCconduitpipe.......dia.......mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws.19/20 mm dia 2 mm thick(CSR-KPWD - Electrical SR, 2023-24: Page No.02, Item No. 1.1.1) | m | 71.07 | 71.07 | 425.0 | False | None | None | False | None | False | 30204.75 | 0 |
3807436 | 144565 | None | code84 | Open Conduit System SupplyingheavygaugePVCconduitpipe.......dia.......mmthickconfirmingtoIS2509withsuitablesizebends,junctionboxes,adhesivepasteetc,andfixingusinginvertedwoodplugsincaseofRCCceilingandRCCwall/stonestructureorrawlplugsincaseofbrickwallsandcementplasteringthedamagedportionusingheavygauge saddles at an interval of 700mm using NF screws.25 mm dia 2 mm thick(CSR-KPWD - Electrical SR, 2023-24: Page No.02, Item No. 1.1.2) | m | 83.43 | 83.43 | 375.0 | False | None | None | False | None | False | 31286.25 | 0 |
3807437 | 144565 | None | code85 | SupplyingheavygaugePVCConduitPipe....dia.......mmthickwithsuitablesizebends,metaljunctionboxesadhesivepasteetc.,bygroovecuttinginthewallandfixingbybracingUorJhooksandcementplasteringuptothewallsurfaceandrunwith18SWGGIfishwire run throughout the conduit wherever necessary.19/20 mm dia 2 mm thick(CSR-KPWD - Electrical SR, 2023-24: Page No.02, Item No. 1.3.1) | m | 70.04 | 70.04 | 425.0 | False | None | None | False | None | False | 29767.0 | 0 |
3807438 | 144565 | None | code86 | SupplyingheavygaugePVCConduitPipe....dia.......mmthickwithsuitablesizebends,metaljunctionboxesadhesivepasteetc.,bygroovecuttinginthewallandfixingbybracingUorJhooksandcementplasteringuptothewallsurfaceandrunwith18SWGGIfishwire run throughout the conduit wherever necessary.25 mm dia 2 mm thick(CSR-KPWD - Electrical SR, 2023-24: Page No.02, Item No. 1.3.2) | m | 81.37 | 81.37 | 325.0 | False | None | None | False | None | False | 26445.25 | 0 |
3807439 | 144565 | None | code87 | Concealed Conduit System
SupplyingheavygaugePVCconduitpipe......mmdia..........mmthickconfirmingtoIS2509withsuitablesizebends,metal/PVCJunctionboxes,adhesivepasteetc.,andrunningbeforeconcretingtheslab.TheconduitshouldbetiedtothereinforcementrodsbyusingbindingwiresandunusedwaysofjunctionboxesandpipeendsshouldbecoveredusingPVCendenclosures,runwith18SWGGIfishwirewherever necessary.32 mm dia 2.5 mm thick(CSR-KPWD - Electrical SR, 2023-24: Page No.01, Item No. 1.2.3) | m | 106.09 | 106.09 | 325.0 | False | None | None | False | None | False | 34479.25 | 0 |
3807440 | 144565 | None | code88 | SupplyingheavygaugePVCConduitPipe....dia.......mmthickwithsuitablesizebends,metaljunctionboxesadhesivepasteetc.,bygroovecuttinginthewallandfixingbybracingUorJhooksandcementplasteringuptothewallsurfaceandrunwith18SWGGIfishwire run throughout the conduit wherever necessary.32 mm dia 2.5 mm thick(CSR-KPWD - Electrical SR, 2023-24: Page No.01, Item No. 1.3.3) | m | 101.97 | 101.97 | 225.0 | False | None | None | False | None | False | 22943.25 | 0 |
3807441 | 144565 | None | code89 | Supplying.........Arated3phasewithneutralbusbarusingrequiredcapacityelectrolyticaluminiumstripscoveredwithheatshrinkablecolouredPVCsleeve,mountedonphenolic/FRP/DMCinsulatorwhicharemountedonpowdercoated40x6mmM.S.flatframeworkinexistingpanelboard.ThebusbarshallhavesuitableholesforterminationofincomingandoutgoingcablesasperISspecification with necessary bolts, nuts and washers etc., complete250 A 4 x 30 x 10 mm Aluminium Strips(CSR-KPWD - Electrical SR, 2023-24: Page No.20, Item No. 5.40.2) | m | 3538.05 | 3538.05 | 60.0 | False | None | None | False | None | False | 212283.0 | 0 |
3807442 | 144565 | None | code90 | WIRES & CABLES
Point wiring using Copper wire with switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral)& 1x1.0 mm2(Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS-694: and latest amendments) witha 6A flush type SP control switch shall be fixed on the existingplastic sheet/ gang box, the other end of the wires shall beterminated with sufficient loose length in a wood/PVC roundblock. complete for each outlet. Short point upto 3m from tapping point to out let via switch(CSR-KPWD - Electrical SR, 2023-24: Page No.05, Item No. 2.1.1) | Point | 293.55 | 293.55 | 275.0 | False | None | None | False | None | False | 80726.25 | 0 |
3807443 | 144565 | None | code91 | WIRES & CABLES
Point wiring using Copper wire with switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral)& 1x1.0 mm2(Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS-694: and latest amendments) witha 6A flush type SP control switch shall be fixed on the existingplastic sheet/ gang box, the other end of the wires shall beterminated with sufficient loose length in a wood/PVC roundblock. complete for each outlet.edium point above 3m upto 6m from tapping point to out let via switch.(CSR-KPWD - Electrical SR, 2023-24: Page No.05, Item No. 2.1.2) | Point | 405.82 | 405.82 | 150.0 | False | None | None | False | None | False | 60873.0 | 0 |
3807444 | 144565 | None | code92 | WIRES & CABLES
Point wiring using Copper wire with switch Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral)& 1x1.0 mm2(Earth wire) FRLS multi strand PVC insulatedcopper wire (confirming to IS-694: and latest amendments) witha 6A flush type SP control switch shall be fixed on the existingplastic sheet/ gang box, the other end of the wires shall beterminated with sufficient loose length in a wood/PVC roundblock. complete for each outlet. Long point above 6m upto 10m from tapping point to out let via switch(CSR-KPWD - Electrical SR, 2023-24: Page No.05, Item No. 2.1.3) | Point | 587.1 | 587.1 | 150.0 | False | None | None | False | None | False | 88065.0 | 0 |
3807445 | 144565 | None | code93 | Supplying6Aflushtypesocketand6AflushtypeSPswitcheithersurface/flushmountinginexistinggangboxorin4mmthickplasticsheetandfixingoveraflushmountedwoodenboxandwiringusingnecessary capacity wires as required as per IS 1293 and IS 3854 6 Amps 3/5 way(CSR-KPWD - Electrical SR, 2023-24: Page No.08, Item No. 3.1.2) | Each | 151.41 | 151.41 | 120.0 | False | None | None | False | None | False | 18169.2 | 0 |
3807446 | 144565 | None | code94 | Supplyingandmounting2Nos.of2Way6Aflushtypeswitcheseithersurface/flushmountedonexistinggangboxorin4mmthickplasticsheetandmountedonaflushmountedwoodenboxandwiringas per IS 3854(CSR-KPWD - Electrical SR, 2023-24: Page No.08, Item No. 3.2) | Each | 175.1 | 175.1 | 55.0 | False | None | None | False | None | False | 9630.5 | 0 |
3807447 | 144565 | None | code95 | Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 1 mm2(CSR-KPWD - Electrical SR, 2023-24: Page No.05, Item No. 2.3.1) | m | 19.57 | 19.57 | 1400.0 | False | None | None | False | None | False | 27398.0 | 0 |
3807448 | 144565 | None | code96 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments- 2.5 mm2 (CSR-KPWD - Electrical SR,2023-24: Page No.05, Item No. 2.3.3) | m | 43.26 | 43.26 | 300.0 | False | None | None | False | None | False | 12978.0 | 0 |
3807449 | 144565 | None | code97 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments- 4.00 mm2 (CSR-KPWD - Electrical SR, 2023-24: Page No.05, Item No. 2.3.4) | m | 64.89 | 64.89 | 3500.0 | False | None | None | False | None | False | 227115.0 | 0 |
3807450 | 144565 | None | code98 | Wiring for lighting/power circuit using one of FRLS PVC
insulated 1100V grade, multistrand copper wire with low
conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments- 10.00 mm2 (CSR-KPWD - Electrical SR, 2023-24: Page No.03, Item No. 2.3.6) | m | 172.01 | 172.01 | 250.0 | False | None | None | False | None | False | 43002.5 | 0 |
3807451 | 144565 | None | code99 | Supplying capacitor type ceiling fan complete with down rodblades, shackle, canopies etc, for operation on 230 V, 50 cycles.Single phase AC supply conforming to ISS-374- 1979 and withdouble ball bearing system.48" Sweep (1200 mm) Regular model(CSR-KPWD - Electrical SR, 2023-24: Page No.30, Item No. 6.3.1) | Each | 3073.52 | 3073.52 | 35.0 | False | None | None | False | None | False | 107573.2 | 0 |
3807452 | 144565 | None | code100 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to theexistingboard together with supplying and fixing 5 A. ceiling rose,necessary length of 23 / 0.0076 inch PVC insulated twintwisted copper wire and wiring(CSR-KPWD - Electrical SR, 2023-24: Page No.57, Item No. 13.10) | Nos | 176.13 | 176.13 | 30.0 | False | None | None | False | None | False | 5283.9 | 0 |
3807453 | 144565 | None | code101 | Supplying And fixing/replacing of 6/16/32A electrical
accessories on existing switch board.-6A Pendant Holder(CSR-KPWD - Electrical SR, 2023-24: Page No.10, Item No. 3.14.6) | Nos | 73.13 | 73.13 | 75.0 | False | None | None | False | None | False | 5484.75 | 0 |
3807454 | 144565 | None | code102 | Supplying And fixing/replacing of 6/16/32A electrical
accessories on existing switch board.- 6A Bakelite Ceiling Rose(CSR-KPWD - Electrical SR, 2023-24: Page No10, Item No. 3.14.5) | Nos | 73.13 | 73.13 | 42.5 | False | None | None | False | None | False | 3108.025 | 0 |
3807455 | 144565 | None | code103 | Supplying of recess mounting non integrated type LED
down light15-18W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceilingclA, LED of Power/COB with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread,life 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosedwith anti glare opal diffuser which enhances the lightinglevel. LED's are driven by HF electronic driver integrated in aseparate control gear assembly., with PF 0.95, power lossshould 5% of lamp Wage, short circuit & open circuitprotection to be integrated in the circuit, THD less than 20%,Life as per LM 79. The operating input voltage should bebetween 130 to 275 V. BIS Approved and Tested byNABL/CPRI accredited laboratory with 2 years Warrantyagainst any manufacturing defect working under standard electrical condition.(CSR-KPWD - Electrical SR, 2023-24: Page No.43, Item No.11.1) | Each | 1329.73 | 1329.73 | 40.0 | False | None | None | False | None | False | 53189.2 | 0 |
3807456 | 144565 | None | code104 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.- 15" Sweep (450 mm)(CSR-KPWD - Electrical SR, 2023-24: Page No.30, Item No. 6.2.2) | Each | 4579.38 | 4579.38 | 7.5 | False | None | None | False | None | False | 34345.35 | 0 |
3807457 | 144565 | None | code105 | Fixing one exhaust fan after making a suitable notch in the
wall and finishing with cement mortar and colouring to matchthe existing wall or brackets, with bolts and nuts and a 5 A,ceiling rose with sufficient length of 23 / 0.0076 inch PVCinsulated twin core wire of approved make with wire meshand wooden frame.(CSR-KPWD - Electrical SR, 2023-24: Page No.57, Item No. 13.13) | Each | 728.21 | 728.21 | 17.5 | False | None | None | False | None | False | 12743.675 | 0 |
3807458 | 144565 | None | code106 | Supplying & fixing of porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers etc., complete. 63 Amps(CSR-KPWD - Electrical SR, 2023-24: Page No.14, Item No. 5.7.3) | Each | 413.03 | 413.03 | 56.0 | False | None | None | False | None | False | 23129.68 | 0 |
3807459 | 144565 | None | code107 | Supplying & fixing of porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers etc., complete. 100 Amps(CSR-KPWD - Electrical SR, 2023-24: Page No.14, Item No. 5.7.4) | Each | 711.73 | 711.73 | 40.0 | False | None | None | False | None | False | 28469.2 | 0 |
3807460 | 144565 | None | code108 | Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross-3withShortcircuitbreakingcapacityof10KandcompletewiringasrequiredconfirmingtoIEC60898. 6 - 32 Amps DP(CSR-KPWD - Electrical SR, 2023-24: Page No.17, Item No. 5.18.4) | Each | 761.17 | 761.17 | 40.0 | False | None | None | False | None | False | 30446.8 | 0 |
3807461 | 144565 | None | code109 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50 - 63 Amps DP(CSR-KPWD - Electrical SR, 2023-24: Page No.17, Item No. 5.18.6) | Each | 1135.06 | 1135.06 | 40.0 | False | None | None | False | None | False | 45402.4 | 0 |
3807462 | 144565 | None | code110 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6 - 32 Amps TPN(CSR-KPWD - Electrical SR, 2023-24: Page No.17, Item No. 5.18.7) | Each | 1768.51 | 1768.51 | 15.0 | False | None | None | False | None | False | 26527.65 | 0 |
3807463 | 144565 | None | code111 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.50 - 63 Amps TPN(CSR-KPWD - Electrical SR, 2023-24: Page No.18, Item No. 5.18.9) | Each | 3180.64 | 3180.64 | 31.0 | False | None | None | False | None | False | 98599.84 | 0 |
3807464 | 144565 | None | code112 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated
painting Made out of 14 SWG MS enclosure.I - Single Door -16 Way SP & N (CSR-KPWD - Electrical SR, 2023-24: Page No.18, Item No. 5.19.5) | Each | 3019.96 | 3019.96 | 12.0 | False | None | None | False | None | False | 36239.52 | 0 |
3807465 | 144565 | None | code113 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coatedpainting Made out of 14 SWG MS enclosure.II - Double Door-12 Way SP & N(CSR-KPWD - Electrical SR, 2023-24: Page No.18, Item No. 5.19.9) | Each | 2398.87 | 2398.87 | 7.5 | False | None | None | False | None | False | 17991.525 | 0 |
3807466 | 144565 | None | code114 | Supplying,fixingandwiringResidualcurrentcircuitbreaker(RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 16A-25A 2 pole(CSR-KPWD - Electrical SR, 2023-24: Page No.18, Item No. 5.20.1) | Each | 4405.31 | 4405.31 | 2.5 | False | None | None | False | None | False | 11013.275 | 0 |
3807467 | 144565 | None | code115 | Supplying,fixingandwiringResidualcurrentcircuitbreaker(RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 32-40 A 2 pole(CSR-KPWD - Electrical SR, 2023-24: Page No.18, Item No. 5.20.4) | Each | 4695.77 | 4695.77 | 2.5 | False | None | None | False | None | False | 11739.425 | 0 |
3807468 | 144565 | None | code116 | Supplying,fixingandwiringResidualcurrentcircuitbreaker(RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 32-40 A 4 pole(CSR-KPWD - Electrical SR, 2023-24: Page No.18, Item No. 5.20.8) | Each | 5301.41 | 5301.41 | 4.0 | False | None | None | False | None | False | 21205.64 | 0 |
3807469 | 144565 | None | code117 | Supplying,fixingandwiringResidualcurrentcircuitbreaker(RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 63 A 4 pole(CSR-KPWD - Electrical SR, 2023-24: Page No.18, Item No. 5.20.10) | Each | 5711.35 | 5711.35 | 4.5 | False | None | None | False | None | False | 25701.075 | 0 |
3807470 | 144565 | None | code118 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall1-3 Way(CSR-KPWD - Electrical SR,2023-24: Page No.8, Item No. 3.4.2) | Each | 163.77 | 163.77 | 20.0 | False | None | None | False | None | False | 3275.4 | 0 |
3807471 | 144565 | None | code119 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall4-5 Way(CSR-KPWD - Electrical SR, 2023-24: Page No.08, Item No. 3.4.3) | Each | 182.31 | 182.31 | 20.0 | False | None | None | False | None | False | 3646.2 | 0 |
3807472 | 144565 | None | code120 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall6 Way(CSR-KPWD - Electrical SR, 2023-24: Page No.08, Item No. 3.4.4) | Each | 226.6 | 226.6 | 20.0 | False | None | None | False | None | False | 4532.0 | 0 |
3807473 | 144565 | None | code121 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall8 Way(CSR-KPWD - Electrical SR, 2023-24: Page No.08, Item No. 3.4.5) | Each | 268.83 | 268.83 | 20.0 | False | None | None | False | None | False | 5376.6 | 0 |
3807474 | 144565 | None | code122 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall10-12 Way (CSR-KPWD - Electrical SR, 2022-23: Page No.08, Item No. 3.4.6) | Each | 328.57 | 328.57 | 20.0 | False | None | None | False | None | False | 6571.4 | 0 |
3807475 | 144565 | None | code123 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 16 Way(CSR-KPWD - Electrical SR, 2023-24: Page No.08, Item No. 3.4.7) | Each | 373.89 | 373.89 | 20.0 | False | None | None | False | None | False | 7477.8 | 0 |
3807476 | 144565 | None | code124 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 3 Module(CSR-KPWD - Electrical SR,2023-24: Page No.08, Item No. 3.5.2) | Each | 165.83 | 165.83 | 20.0 | False | None | None | False | None | False | 3316.6 | 0 |
3807477 | 144565 | None | code125 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 4 Module(CSR-KPWD - Electrical SR, 2023-24: Page No.08, Item No. 3.5.3) | Each | 180.25 | 180.25 | 20.0 | False | None | None | False | None | False | 3605.0 | 0 |
3807478 | 144565 | None | code126 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 6 Module(CSR-KPWD - Electrical SR, 2023-24: Page No.08, Item No. 3.5.4) | Each | 241.02 | 241.02 | 20.0 | False | None | None | False | None | False | 4820.4 | 0 |
3807479 | 144565 | None | code127 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 8 Module(CSR-KPWD - Electrical SR, 2023-24: Page No.08, Item No. 3.5.5) | Each | 292.52 | 292.52 | 20.0 | False | None | None | False | None | False | 5850.4 | 0 |
3807480 | 144565 | None | code128 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box10-12 Module(CSR-KPWD - Electrical SR, 2023-24: Page No.08, Item No. 3.5.6) | Each | 354.32 | 354.32 | 20.0 | False | None | None | False | None | False | 7086.4 | 0 |
3807481 | 144565 | None | code129 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 16 Module(CSR-KPWD - Electrical SR, 2023-24: Page No.08, Item No. 3.5.7) | Each | 408.91 | 408.91 | 20.0 | False | None | None | False | None | False | 8178.2 | 0 |
3807482 | 144565 | None | code130 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A One Way Switch (CSR-KPWD - Electrical SR,2023-24: Page No.09, Item No. 3.6.1) | Each | 105.06 | 105.06 | 22.5 | False | None | None | False | None | False | 2363.85 | 0 |
3807483 | 144565 | None | code131 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Two Way Switch(CSR-KPWD - Electrical SR, 2023-24: Page No.09, Item No. 3.6.2) | Each | 170.98 | 170.98 | 20.0 | False | None | None | False | None | False | 3419.6 | 0 |
3807484 | 144565 | None | code132 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Three Way socket(CSR-KPWD - Electrical SR, 2023-24: Page No.09, Item No. 3.6.3) | Each | 176.13 | 176.13 | 9.0 | False | None | None | False | None | False | 1585.17 | 0 |
3807485 | 144565 | None | code133 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16A One Way Switch(CSR-KPWD - Electrical SR, 2023-24: Page No.09, Item No. 3.6.7) | Each | 185.4 | 185.4 | 22.5 | False | None | None | False | None | False | 4171.5 | 0 |
3807486 | 144565 | None | code134 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6/16A Universal Socket(CSR-KPWD - Electrical SR, 2023-24: Page No.09, Item No. 3.6.10) | Each | 243.08 | 243.08 | 23.0 | False | None | None | False | None | False | 5590.84 | 0 |
3807487 | 144565 | None | code135 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP Switch(CSR-KPWD - Electrical SR, 2023-24: Page No.09, Item No. 3.6.9) | Each | 335.78 | 335.78 | 23.0 | False | None | None | False | None | False | 7722.94 | 0 |
3807488 | 144565 | None | code136 | Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. PowerInput: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 2' - 9/10 W(CSR-KPWD - Electrical SR, 2023-24: Page No.43, Item No. 11.3.1) | Each | 567.53 | 567.53 | 22.5 | False | None | None | False | None | False | 12769.425 | 0 |
3807489 | 144565 | None | code137 | Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. PowerInput: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 20/22 W(CSR-KPWD - Electrical SR, 2023-24: Page No.43, Item No. 11.3.2) | Each | 710.7 | 710.7 | 22.5 | False | None | None | False | None | False | 15990.75 | 0 |
3807490 | 144565 | None | code138 | Supplying of .....feet -PVC Batten with integrated LED tube ....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. PowerInput: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 36/40 W(CSR-KPWD - Electrical SR, 2023-24: Page No.43, Item No. 11.3.3) | Each | 1307.07 | 1307.07 | 22.5 | False | None | None | False | None | False | 29409.075 | 0 |
3807491 | 144565 | None | code139 | Supply of round/square recess/surface mounted rolling
type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained bycircular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical conditionLED square or round down light 5-6W(CSR-KPWD - Electrical SR, 2023-24: Page No.44, Item No. 11.5.1) | Each | 588.13 | 588.13 | 25.0 | False | None | None | False | None | False | 14703.25 | 0 |
3807492 | 144565 | None | code140 | Supply of round/square recess/surface mounted rolling
type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained bycircular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 10-12W(CSR-KPWD - Electrical SR, 2023-24: Page No.44, Item No. 11.5.2) | Each | 911.55 | 911.55 | 25.0 | False | None | None | False | None | False | 22788.75 | 0 |
3807493 | 144565 | None | code141 | Supply of round/square recess/surface mounted rolling
type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained bycircular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @50/60Hz & Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical conditionLED square or round down light 15-18W(CSR-KPWD - Electrical SR, 2023-24: Page No.44, Item No. 11.5.3) | Each | 1363.72 | 1363.72 | 25.0 | False | None | None | False | None | False | 34093.0 | 0 |
3807494 | 144565 | None | code142 | Removal of Unserviceable Soil with Disposal upto a suitable
distance as directed by the Engineer incharge of work(KPWD SR 2023-24 V-3 P.No. 17, I.No. 3.1) | Cum | 87.55 | 87.55 | 1586.77 | False | None | None | False | None | False | 138921.7135 | 0 |
3807495 | 144565 | None | code143 | Cutting and removing jauliflora bushes above 1.50 m upto 3.00 m girth excluding removal of stumps and including burning or disposing off the materials as directed with all other ancillary operations complete.(MI-WRD SR 2023-24 V-4 P.No. 101, I.No. WRD-8.2.2) | Each | 52.02 | 52.02 | 600.0 | False | None | None | False | None | False | 31212.0 | 0 |
3807496 | 144565 | None | code144 | Cutting and burning or disposing off Apu / Jondu from marshy areas as directed with all other ancillary operations complete (MI-WRD SR 2023-24 V-4 P.No. 101, I.No. WRD-8.3) | Sqm | 9.68 | 9.68 | 21156.965 | False | None | None | False | None | False | 204799.4212 | 0 |
3807497 | 144565 | None | code145 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including Cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.(KPWD 2023-24 Page No.37,Vol-1 I.no.1.14.1) | Cum | 105.06 | 105.06 | 183.6 | False | None | None | False | None | False | 19289.016 | 0 |
3807498 | 144565 | None | code146 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.(KPWD 2023-24 Page No.44,Vol-2 I.no.8.19.1) | Sqm | 262.65 | 262.65 | 379.919 | False | None | None | False | None | False | 99785.72535 | 0 |
3807499 | 144565 | None | code147 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work..(KPWD 2023-24 Page No.7,Vol-1 I.no.1.8) | Cum | 488.22 | 488.22 | 902.901 | False | None | None | False | None | False | 440814.32622 | 0 |
3807500 | 144565 | None | code148 | Providing and laying in position cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other. Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates(KPWD 2023-24 Page No.16,Vol-1 I.no.2.4.1) | Cum | 6596.12 | 6596.12 | 54.53 | False | None | None | False | None | False | 359686.4236 | 0 |
3807501 | 144565 | None | code149 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(KPWD 2023-24 Page No.82,Vol-2 I.no.11.16.2) | Kg | 151.41 | 151.41 | 532.0 | False | None | None | False | None | False | 80550.12 | 0 |
3807502 | 144565 | None | code150 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using selfdrilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required(KPWD 2023-24 Page No.26,Vol-2 I.no.7.38) | Sqm | 585.04 | 585.04 | 40.0 | False | None | None | False | None | False | 23401.6 | 0 |
3807503 | 144565 | None | code151 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density.(KPWD 2023-24 Page No.26,Vol-3 I.no.4.17) | Cum | 2635.77 | 2635.77 | 268.425 | False | None | None | False | None | False | 707506.56225 | 0 |
3807504 | 144565 | None | code152 | Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge.
(The cost of PCC shall be paid extra)-600 x 300 x 150 mm size(KPWD 2023-24 Page No.74,Vol-3 I.no.8.42.3) | m | 476.89 | 476.89 | 1760.0 | False | None | None | False | None | False | 839326.4 | 0 |
3807505 | 144565 | None | code153 | Providing and laying 80mm thick factory made precast M -30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Commercial Traffic Axle load repetitions upto 10MSA & for Residential Streets of approved shape and colour, laid in required pattern and including over 40mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. (WMM/WBM Base to be paid separately as per relevant technical specification)(PWD SR 2023-24 Vol:3 P.NO.51 I.No.6.8.2) | Sqm | 1195.83 | 1195.83 | 1928.5 | False | None | None | False | None | False | 2306158.155 | 0 |
3807506 | 144565 | None | code154 | Supplyinganddrawing3coreflatPVCsheathedsubmersiblepumpcablemanufacturedwithelectrolyticgradecopperwithflexiblecopperwithlowresistanceconductorconfirmingto13:8130,1984andvirgingradePVCinsulationandpowdercoatingextrudedPVCsheathedsuitable for working voltage upto 1100 Volts as per IS-694:1990.3C x 2.5 mm2(PWD Ele SR 2023-24 Vol:6 P.NO.07 I.No.2.6.1) | m | 120.51 | 120.51 | 2000.0 | False | None | None | False | None | False | 241020.0 | 0 |
3807507 | 144565 | None | code155 | Fabricating,supplyinganderectionof...mslonghotdipGalvanizedConicalhotdipPolewithBSEN10025gradeS355JOsteelplateforshaft,IS2062forbaseplatewithdooropeningarrangements,includingsuitableboards,BakelitesheetandMCBsasperISspecificationssuitabletowithstandthewindspeedof47m/sfor.......mPoleinsinglesectionandsinglejointweldedasperIS9595/IS10178AWShavingdimensionsbottom.....mm,top...mmwith3mmthick,suitablebaseplateand4Nosof.........longJboltsalongwithtemplateandthePoleshallbehotdipgalvanizedinsingledippingwithnotlessthan65micronasperASTM-A123and153etc.,(excluding foundation) as per drawing appended.3 m - Top 77 mm and Bottom 105 mm dia(KPWD Ele 2023-24 Page No.12.Vol-6 I.no.4.4.1) | Each | 6798.0 | 6798.0 | 14.0 | False | None | None | False | None | False | 95172.0 | 0 |
3807508 | 144565 | None | code156 | Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.14 SWG(S.R.page 55 SL NO 5.42.1 of Electrical S.R 2021-22) | Sq CM | 0.52 | 0.52 | 42000.0 | False | None | None | False | None | False | 21840.0 | 0 |
3807509 | 144565 | None | code157 | SupplyingandfixingMouldedCaseCircuitBreaker(MCCB)overtheexistingwood/panelboardusingnecessaryscrews,bolts,nuts,necessaryphaseseparators,handleandwiringcomplete.ProtectionofOverloadandShortcircuitwithadjustablethermalmagneticrelease,MicroprocessorreleaseshallhaveEarthFaultasperIS/IEC60947-2.(Icu=100%lcs).In4PMCCB,allPolesshouldhaveprotectionforShort-Cicrcuit/OverLoad.ForMicroprocessorMCCBSFacilityforsegregatingPriorityandNon-PriorityloadsmustbeavailableintheMCCB.MCCBshallbeprovidedwithdoubleinsulation(insulationbetweenfrontcoverandinternalpowercircuitstoavoidanyaccidentalcontactwithlivecurrentcarryingpathwiththefrontcoveropen).Multi-polebreakersshallbedesignedtobreakallthepolessimultaneously and they shall have a single mechanism.-THREE Pole-100 A 25 kA(KPWD Ele 2023-24 Page No.17.Vol-6 I.no.5.15.1) | Each | 6268.58 | 6268.58 | 4.0 | False | None | None | False | None | False | 25074.32 | 0 |
3807510 | 144565 | None | code158 | Supplying and fixing of Shunt trip suitable for MCCB.CBCT(KPWD Ele 2023-24 Page No.17.Vol-6 I.no.5.16) | Each | 1754.09 | 1754.09 | 4.0 | False | None | None | False | None | False | 7016.36 | 0 |
3807511 | 144565 | None | code159 | Supplying and fixing of solar Lux level street light control switch three phase including suitable capacity contactor-12 kW(KPWD Ele 2023-24 Page No.21.Vol-6 I.no.5.50.3) | Each | 17134.05 | 17134.05 | 9.0 | False | None | None | False | None | False | 154206.45 | 0 |
3807512 | 144565 | None | code160 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification(KPWD 2023-24 Page No.18,Vol-1 I.no.2.11H) | Tonne | 81381.33 | 81381.33 | 0.0481 | False | None | None | False | None | False | 3914.441973 | 0 |
3807513 | 144565 | None | code161 | SupplyingandfixingangleironframeworkfabricatedoutofM.S.angleiron..andM.S.Flat......withbolts,washersetc.,andpaintedwith 2 coats of red oxide and then two coats of approved paint.40 x 40 x 6 mm (KPWD Ele 2023-24 Page No.20.Vol-6 I.no.5.41.1) | m | 314.15 | 314.15 | 40.0 | False | None | None | False | None | False | 12566.0 | 0 |
3807514 | 144565 | None | code162 | Supplyingandfixinghylumplasticsheet3mmthickwithnecessarynitchesforfixingswitches,regulatorsetc.,andfixingonexistingwood or metal box using N. F. screws.(KPWD Ele 2023-24 Page No.09.Vol-6 I.no.3.9) | Sq CM | 0.36 | 0.36 | 16000.0 | False | None | None | False | None | False | 5760.0 | 0 |
3807515 | 144565 | None | code163 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947-40 A(KPWD Ele 2023-24 Page No.16.Vol-6 I.no.5.14.3) | Each | 6302.57 | 6302.57 | 1.0 | False | None | None | False | None | False | 6302.57 | 0 |
3807516 | 144565 | None | code164 | SupplyingandfixingMicroprocessorbasedElectronictimer(withoutcontactor,DinMountingusingnecessarybolts,nutsandwashersetc.,.)3-120sec setting. (KPWD Ele 2023-24 Page No.21.Vol-6 I.no.5.47) | Each | 2384.45 | 2384.45 | 1.0 | False | None | None | False | None | False | 2384.45 | 0 |
3807517 | 144565 | None | code165 | Supplyandfixingpolishedwoodboardmadeofnotlessthan15mmthickplankonbothsidesofnotmorethan2piecesandfixingthesametothewallusingtaperedinvertedwoodenplugsscrews. 12" x 12" x 2"(KPWD Ele 2023-24 Page No.14.Vol-6 I.no.5.6.4) | Each | 186.43 | 186.43 | 1.0 | False | None | None | False | None | False | 186.43 | 0 |
3807518 | 144565 | None | code166 | Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010-6 mm2(KPWD Ele 2023-24 Page No.05.Vol-6 I.no.2.3.5) | m | 94.76 | 94.76 | 505.0 | False | None | None | False | None | False | 47853.8 | 0 |
3807519 | 144565 | None | code167 | SupplyinganddrawingFlexibleMulticoreCablemanufacturedwithelectrolyticgradeflexiblecopperwithlowconductorconfirmingtoIS81301984and(Virgin)PVCinsulationsheathedsuitableforworking voltage upto 1100 Volts as per IS-694:1990--3C x 2.5 mm2(KPWD Ele 2023-24 Page No.06.Vol-6 I.no.2.5.8) | m | 116.39 | 116.39 | 120.0 | False | None | None | False | None | False | 13966.8 | 0 |
3807520 | 144565 | None | code168 | Fabrication,Supplying,Erection,TestingandCommissioningof......mslongPolygonhighmastwithSingle/Multipletelescopicsectionshaving,(minimumoverlapdistanceof1.5timesoftopsection)thicknessasperBSEN10025grades355JO/ASTMA572.50steelsheetplateforshaftsuitabletowithstandawindvelocityof47m/sasperIS875part3(asperGADrawing).BaseplateasperIS2062/ASTMA572,50.ThemastshallbeGalvanizedinsingleHotdipasperBSENISO1461/ASTMA123withanaverage70micronsasperIS2629,andweldedasperBS5135SingleL,SeamjointThemastshallhave2WayheadframewithdiecastLM,6pulleys,stainlesssteelaxle,PhosphorusBronzebearingbushpress,fittedwithseparateguidesfor2runsof5mmdia,stainlesssteelwireropeofAISI304grade7/19,core,(FactorofSafetyasperTRno,7).2.5mm2EPRinsulatedPCPsheathedtrailingpowercablehousedinsidethebottomshaftofmastwithdoorhavinglockingarrangementThemastshallhavemanual/powertool(Suitablereversiblegearedmotoroperatingon230/415V,50Hz,shallbeprovideabove15Mtrmast)Themastshallhavelanternof2segments,suitablediawithmaxloadcarryingcapacityasperIS1239.ThemastshallbeerectedonexistingRCCfooting.Themastshallbesuppliedwith3mmthicktemplate,lightningarresterof1.2mlengthgalvanizedpipewithtoparrowfittedontopoftheheadframecoverandGLStypeaviationtwinlAfittingwithwiringcomplete.(excludingfoundation)asper technical data.12 m/12.5 m - Top 100 mm and Bottom 310 mm dia(KPWD Ele 2023-24 Page No.13.Vol-6 I.no.4.5.1) | Each | 134930.0 | 134930.0 | 1.0 | False | None | None | False | None | False | 134930.0 | 0 |
3807521 | 144565 | None | code169 | Supplying,fixingandwiring3PhaseDigitalAmmeter/Voltmeter (KPWD Ele 2023-24 Page No.19.Vol-6 I.no.5.29) | Each | 1467.75 | 1467.75 | 11.0 | False | None | None | False | None | False | 16145.25 | 0 |
3807522 | 144565 | None | code170 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975-16 Sqmm, 4 Core,-(287206) (11 GI Strips - 4 x 0.8 mm)(KPWD Ele 2023-24 Page No.13.Vol-6 I.no.32.05) | Km | 146097.26 | 146097.26 | 0.4 | False | None | None | False | None | False | 58438.904 | 0 |
3807523 | 144565 | None | code171 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975-25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm) (KPWD Ele 2023-24 Page No.13.Vol-6 I.no.32.07) | Km | 143735.47 | 143735.47 | 0.4 | False | None | None | False | None | False | 57494.188 | 0 |
3807524 | 144565 | None | code172 | Optical Fibre Cable (OFC) and its Accessories-HDPE/PLB Pipe 50/42 mm(KPWD Ele 2023-24 Page No.30.Vol-6 I.no.66.04) | Km | 87564.42 | 87564.42 | 0.4 | False | None | None | False | None | False | 35025.768 | 0 |
3807525 | 144565 | None | code173 | Supplying,fixing,wiring,earthelectrodeforgroundingconduits,I.C.cutoutsandotherequipment'sonthemeterboardusing40mmdia2.90mmthickGIpipe2.5mlongburiedinapit.Thepitshouldbefilledwithequalproportionofsaltandcharcoal150mmall-roundthepipetocompletedepth.Theconnectionfromthepipetotheconduitetc.,istobeestablishedthroughGIwireofsizeasperlSIspecification7.3.3.ofIS732using12mmdiabolts,nuts,washersandchecknutsetc., the pipe shall have 16 through holes of 12 mm dia(KPWD Ele 2023-24 Page No.54.Vol-6 I.no.12.56) | Nos | 3615.3 | 3615.3 | 5.0 | False | None | None | False | None | False | 18076.5 | 0 |
3807526 | 144565 | None | code174 | Guy Wire & GI Wire as per IS-2141 -8 SWG GI Wire(4.064 mm Dia), Std Wt: 131 Kg/KM(KPWD Ele 2023-24 Page No.05.Vol-6 I.no.8.02) | MT | 77291.2 | 77291.2 | 0.05 | False | None | None | False | None | False | 3864.56 | 0 |
3807527 | 144565 | None | code175 | Pipe-GI-iv) 50 mm dia B class(KPWD Ele 2023-24 Page No.159.Vol-4 I.no.39) | m | 314.15 | 314.15 | 20.0 | False | None | None | False | None | False | 6283.0 | 0 |
3807528 | 144565 | None | code176 | Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. ESCOM Part 4 11kv Labour SR 2023-24 Pg No: 63 Item No:29.01 | Cum | 249.26 | 249.26 | 150.0 | False | None | None | False | None | False | 37389.0 | 0 |
3807529 | 144565 | None | code177 | Transporting Cable from Store to work spot including loading and unloading (including Crane and other equipment charges if any) 2.5 to 25 Sqmm (Single/3.5/4 Core) ESCOM Part 4 11kv Labour SR 2023-24 Pg No: 52 Item No:20.05 | Km | 1222.0 | 1222.0 | 0.4 | False | None | None | False | None | False | 488.8 | 0 |
3807530 | 144565 | None | code178 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff-LT Cable-2.5 to 25 Sqmm(KPWD Ele 2023-24 Page No.52.Vol-6 I.no.21.05) | Km | 21512.58 | 21512.58 | 0.4 | False | None | None | False | None | False | 8605.032 | 0 |
3807531 | 144565 | None | code179 | Clearing Grass and Removal of Rubbish & dumping to outside periphery by manual means(KPWD 2023-24 Page No.9.Vol-3 I.no.2.3) | 100 Sqm | 381.1 | 381.1 | 33.905 | False | None | None | False | None | False | 12921.1955 | 0 |
3807532 | 144565 | None | code180 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing
off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth(KPWD 2023-24 Page No.8.Vol-1 I.no.1.12) | Cum | 97.85 | 97.85 | 1186.675 | False | None | None | False | None | False | 116116.14875 | 0 |
3807533 | 144565 | None | code181 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in Charge(KPWD CSR-2023-24-Vol-02-P.NO-84,I.NO-11.25.2) | Kgs | 140.08 | 140.08 | 3774.618 | False | None | None | False | None | False | 528748.48944 | 0 |
3807534 | 144565 | None | code182 | Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on steel frame work complete.(KPWD CSR-2023-24-Vol-02-P.NO-26 I.NO-7.35) | Sqm | 302.82 | 302.82 | 162.92 | False | None | None | False | None | False | 49335.4344 | 0 |
3807535 | 144565 | None | code183 | Providing Mangalore Ridge tiles set in C.M. 1:2 and pointed with C.M. 1:2.(KPWD CSR-2023-24-Vol-02-P.NO-107 I.NO-20.98) | m | 256.47 | 256.47 | 40.0 | False | None | None | False | None | False | 10258.8 | 0 |
3807536 | 144565 | None | code184 | Painting Two Coats on New Concrete Surfaces Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces(PWD SR 2023-24 Vol:3 P.NO.66 I.No.8.10) | Sqm | 112.27 | 112.27 | 273.0 | False | None | None | False | None | False | 30649.71 | 0 |
3807537 | 144565 | None | code185 | Fabricating,supplyinganderectionof...mslonghotdipGalvanizedConicalhotdipPolewithBSEN10025gradeS355JOsteelplateforshaft,IS2062forbaseplatewithdooropeningarrangements,includingsuitableboards,BakelitesheetandMCBsasperISspecificationssuitabletowithstandthewindspeedof47m/sfor.......mPoleinsinglesectionandsinglejointweldedasperIS9595/IS10178AWShavingdimensionsbottom.....mm,top...mmwith3mmthick,suitablebaseplateand4Nosof.........longJboltsalongwithtemplateandthePoleshallbehotdipgalvanizedinsingledippingwithnotlessthan65micronasperASTM-A123and153etc.,(excluding foundation) as per drawing appended.4 m - Top 75 mm and Bottom 115 mm dia(PWD Ele SR 2023-24 Vol:6 P.NO.11 I.No.4.4.2) | Each | 8755.0 | 8755.0 | 30.0 | False | None | None | False | None | False | 262650.0 | 0 |
3807538 | 144565 | None | code186 | CROSS WALKERN Providing, Supplying, fixing, Installation, commissioning and trial run of Cross Walker. Metal:All tubular steel of 2.5mm thickness are galvanized and zinc dipped joints are robotic welded.All welded joints are scalloped as necessary and welded to an approved MIG process.All welds are dressed off removing all sharpedges and burns.Zinc primer paint is applied at all the welded points prior to finishing. All metal parts are powder coated using AKZO nobel-Great wall powder to the thickness of 80-120 microns.All metal Parts are to be testedin salt spraymachine that uses a 5% NaO solution in accordance to ISO 7227 to handle corrosion for 3000Hrs. Rubber:High quality grip rubber is used for the handles. Bearings Maintenance free ball bearings.Scope of delivery:1 Completely pre- assembled equipment model, Maintenance: Maintain according to EN 16630 and as per maintenance guide,Safety: All products must be tested and certified to meet EN 16630 safety standards with GS test mark.The EN 16630 certificates must be issued by a reputed notified international certifying agency such as IPEMA, TUV, CPSC or SGS only.The GS mark EN 16630 Certificates must be in the name of tendering party and not any 3rd Party. All products must clearly display the GS mark as issued in the EN 16630 safety certificates. Size LxWxH: 2015 x615x1360mm (min) Weight: 93 KG (min) Safety Area: 5015x3015mm (min), Capacity 2 persons. The work includes all other incidental works required to complete the work in all respects for smooth functioning of the equipment at all times in all respects for its intended use. The works required in fixing the eqlupment on site as per the site condition. The cost includes, cost of transportation, cost of labour, HOM of machinery etc., required to complete the work. As per the direction of Engineer-in-charge | Nos | 188720.0 | 188720.0 | 1.0 | False | None | None | False | None | False | 188720.0 | 0 |
3807539 | 144565 | None | code187 | LEG PRESS -Providing, Supplying, fixing, installation, commissioning and trial run of Leg Press. Metal:All tubular steel of 2.5mm thickness are galvanized and zinc dipped,joints are robotic welded. All welded joints Jare scalloped as necessary and welded to an approved MIG process.All welds are dressed off removing all sharpedges and burns.Zinc primer paint is applied at all the welded points prior to finishing. All metal parts are powder coated using AKZO nobel-Great wall powder to the thickness of 80-120 microns.All metal Parts are to be testedin salt spraymachine that uses a 5% NaCl solution in accordance to 1507227 to handle corrosion for 3000Hrs. Rubber:High quality grip rubber is used for the handles. Bearings Maintenance free ball bearings Scope of delivery:1 Completely pre-assembled equipment model, Maintenance: Maintain according to EN 16630 and as per maintenance guide,Safety: All products must be tested and certified to meet EN 16630 safety standards with GS Nos test mark. The EN 16630 certificates must be issued by a reputed notified international certifying agency such as IPEMA, TUV, CPSC or SGS only.The GS mark EN 16630 Certificates must be in the name of tendering party and not any 3rd Party. All products must clearly display the GS mark as issued in the EN 16630 safety certificates, Size LxWxH: 2270 x635x1640mm (min) Weight: 60.20KG (min) Safety Area: 5300x3685mm (min), Capacity 2 persons. The work includes all other incidental works required to complete the work in all respects for smooth functioning of the equipment at all times in all respects for its intended use. The works required in fixing the eqiupment on site as per the site condition. The cost includes, cost of transportation, cost of labour, HOM of machinery etc., required to complete the work. As per the direction of Engineer-in-charge | Nos | 178301.0 | 178301.0 | 2.0 | False | None | None | False | None | False | 356602.0 | 0 |
3807540 | 144565 | None | code188 | Leg & Thigh Excercise/Air Walker-Providing Supplying fixing, installation, commissioning and trial run of Air Walker. Metai All tubular steel of 2.5mm thickness are galvanized and zinc dipped joints are robotic weided. All welded joints are scalloped as necessary and welded to an approved MIG process. All welds are dressed off removing all sharpedges and burns. Zinc primer paint is applied at all the welded points prior to finishing. All metal parts are powder coated using AKZO nobel-Great wall powder to the thickness of 80-120 microns. All metal Parts are to be testedin salt spraymachine that uses a 5% NaCl solution in accordance to ISO7227 to handle corrosion for 3000Hrs. Rubber High quality grip rubber is used for the handies. Bearings Maintenance free ball bearings Scope of delivery 1 Completely pre-assembled equipment model, Maintenance Maintain according to EN 16630 and as per maintenance guide, Safety: All products must be tested and certified to meet EN 16630 safety standards with GS test mark The EN 16630 certificates must be issued by a reputed notified international certifying agency such as IPEMA, TUV, CPSC or SGS only. The GS mark EN 16630 Certificates must be in the name of tendering party and not any 3rd Party. All products must clearly display the GS mark as issued in the EN 16630 safety certificates. Size LxWxH: 1065 x615x1364mm (min) Weight 51KG (min) Safety Area: 4090x3555mm (min), Capacity 1 persons The work includes all other incidental works required to complete the work in all respects for smooth functioning of the equipment at all times in all respects for its intended use. The works required in fixing the eqiupment on site as per the site condition. The cost includes, cost of transportation, cost of labour,HOM of machinery etc., required to complete the work. As per the direction of Engineer-in-charge | Nos | 119768.0 | 119768.0 | 2.0 | False | None | None | False | None | False | 239536.0 | 0 |
3807541 | 144565 | None | code189 | Seated Chest Press
Providing. Supplying, fixing, installation, commissioning and trial run of Seated chest Press. Metal All tubular steel of 2.5mm thickness are galvanized and zinc dipped joints are robotic welded.All welded joints are scalloped as necessary and welded to an approved MIG process.All welds are dressed off removing all sharpedges and burns.Zinc primer paint is applied at all the welded points prior to finishing. All metal parts are powder coated using AKZO nobel-Great wall powder to the thickness of 80-120 microns.All metal Parts are to be testedin salt spraymachine that uses a 5%Na solution in accordance to ISO7227 to handle corrosion for 3000Hrs. Rubber High quality grip rubber is used for the handles. Bearings Maintenance free ball bearings.Scope of delivery:1 Completely pre-assembled equipment model, Maintenance: Maintain according to EN 16630 and as per maintenance guide,Safety: All products must be tested and certified to meet EN 16630 safety standards with GS test mark. The EN 16630 certificates must be issued by a reputed notified intemational certifying agency such as IPEMA, TUV, CPSC or SGS only.The GS mark EN 16630 Certificates must be in the name of tendering party and not any 3rd Party. All products must clearly display the GS mark as issued in the EN 16630 safety certificates. Size LxWxH: 1955 x733x2058mm (min) Weight: 86 60KG (min) Safety Area: 5545x4470mm (min),Capacity 2 persons The work includes all other incidental works required to complete the work in all respects for smooth functioning of the equipment at all times in all respects for its intended use. The works required in fixing the eqiupment on site as per the site condition. The cost includes, cost of transportation, cost of labour, HOM of machinery etc., required to complete the work. As per the direction of Engineer-in-charge | Nos | 189106.0 | 189106.0 | 2.0 | False | None | None | False | None | False | 378212.0 | 0 |
3807542 | 144565 | None | code190 | TAI CHI WHEEL-Providing Supplying, fixing installation, commissioning and trial run of Thi chi Wheel. Metal:All tubular steel of 2.5mm thickness are galvanized and zinc dipped joints are robotic welded.All welded joints are scalloped as necessary and welded to an approved MIG process.All welds are dressed off removing all sharpedges and burns.Zinc primer paint is applied at all the welded points prior to finishing. All metal parts are powder coated using AKZO nobel-Great wall powder to the thickness of 80-120 microns.All metal Parts are to be testedin salt spraymachine that uses a 5% NaC solution in accordance to 1507227 to handle corrosion for 3000Hrs. Rubber:High quality grip rubber is used for the handles. Bearings Maintenance free ball bearings.Scope of delivery:1 Completely pre- assembled equipment model, Maintenance: Maintain according to EN 16630 and as per maintenance guide Safety: All products must be tested and certified to meet EN 16630 safety standards with GS test mark. The EN 16630 certificates must be issued by a reputed notified international certifying agency such as IPEMA, TUV, CPSC or SGS only.The GS mark EN 16630 Certificates must be in the name of tendering party and not any 3rd Party. All products must clearly display the GS mark as issued in the EN 16630 safety certificates. Size LxWxH: 1120x1150x1620mm (min) Weight: 39.00KG (min) Safety Area: 3520x3550mm (min),Capacity 3 persons The work includes all other incidental works required to complete the work in all respects for smooth functioning of the equipment at all times in all respects for its intended use. The works required in fixing the eqiupment on site as per the site condition. The cost includes, cost of transportation, cost of labour, HOM of machinery etc., required to complete the work. As per the direction of Engineer-in-charge | Nos | 92753.0 | 92753.0 | 2.0 | False | None | None | False | None | False | 185506.0 | 0 |
3807543 | 144565 | None | code191 | SITTING BENCHES
Providing and laying Surface Mount Reinforcement Bench Conforming to RDSO spect, without Arm rest and Back support with material specification of RCC M-30 Grade con le mix in accordance with 15: 10269/Latest in gray cement by using vibro-compaction technique and with reinforcement as detailed in Govng, speen. TMT reinforcement bars conforming to IS: 1786/1 of dia 10 mm used as main reinforcement bar and 4 mm dia mild steel bars used as stirrups as per drawing, Stirrups of 10 nos.-4 mm dia bar @ 150 mm C/C and Main Reinforcement 4 nos.-10 mm din bar. Each seating plank (bottom) of bench bolted with leg by help of 12 mm dia. x 65 mm length galvanized steel countersunk bolts with EVA washer - Backrest planks fitted with half threaded carriage bolts and nuts of size 165 mm X 8 mm dia with EVA & steel washer. Plank Dimension-1500mm x 440mm, Seat height from the ground 450mm, Distance between both legs. 340mm Architect drawing and direction. The work includes all other incidental works required to complete the work in all respects for smooth functioning of the equipment at all times in all respects for its intended use. The works required in fixing the eqiupment on site as per the site condition. The cost includes, cost of transportation, cost of labour, HOM of machinery etc., required to complete the work. As per the direction of Engineer-in-charge | Nos | 15340.0 | 15340.0 | 30.0 | False | None | None | False | None | False | 460200.0 | 0 |