1725276878000 | 0 | None | None | Buildings | Construction of Dinning hall for Powrakarmikas in KGF CMC under Amruth Nagarothana Phase 04 | 1694824.08 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3903630 | 150462 | None | code01 | RCC (M20) Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size gradedcrushed coarse aggregates [PWD SR 2021-22 Vol:1 P.NO.16 I.No:2.5.1] For Columns considered 70% | Cum | 11721.84 | 11721.84 | 5.38 | False | None | None | False | None | False | 63063.4992 | 0 | 3903631 | 150462 | None | code02 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates [PWD SR 2023-24 Vol:1 P.NO.17 I.No:2.5.1] For Roof Beam considered 60% | Cum | 11032.32 | 11032.32 | 12.54 | False | None | None | False | None | False | 138345.2928 | 0 | 3903632 | 150462 | None | code03 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates [PWD SR 2023-24 Vol:1 P.NO.17 I.No:2.5.1] For Roof Slab considered 50% | Cum | 10342.8 | 10342.8 | 31.42 | False | None | None | False | None | False | 324970.776 | 0 | 3903633 | 150462 | None | code04 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification [PWD SR 2023-24 Vol:1 P.NO.18 I.No: 2.11a] | Tonne | 93035.28 | 93035.28 | 5.77 | False | None | None | False | None | False | 536813.5656 | 0 | 3903634 | 150462 | None | code05 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications..[PWD SR 2023-24 Vol:2 P.NO.17I.No: 6.32] | Sqm | 1349.3 | 1349.3 | 213.99 | False | None | None | False | None | False | 288736.707 | 0 | 3903635 | 150462 | None | code06 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.[PWD SR 2023-24 Vol:2 P.NO.17I.No: 6.34] | Sqm | 1137.12 | 1137.12 | 76.15 | False | None | None | False | None | False | 86591.688 | 0 | 3903636 | 150462 | None | code07 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smoot rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge..[PWD SR 2023-24 Vol:2 P.NO.41 I.No: 8.1.2] | Sqm | 248.23 | 248.23 | 225.33 | False | None | None | False | None | False | 55933.6659 | 0 | 3903637 | 150462 | None | code08 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge..[PWD SR 2023-24 Vol:2 P.NO.41 I.No: 8.3.2] | Sqm | 342.99 | 342.99 | 239.84 | False | None | None | False | None | False | 82262.7216 | 0 | 3903638 | 150462 | None | code09 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @ 1.43 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade,after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.[PWD SR 2023-24 Vol:2 P.NO.46 I.No: 8.31] | Sqm | 183.34 | 183.34 | 239.84 | False | None | None | False | None | False | 43972.2656 | 0 | 3903639 | 150462 | None | code10 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately) Size of Tile 500x500 mm [PWD SR 2023-24 Vol:2 P.NO.62 I.No:9.12.1] | Sqm | 1114.46 | 1114.46 | 66.52 | False | None | None | False | None | False | 74133.8792 | 0 |
|