1723643147000 | 1 | None | None | Water supply/sewage lines | Existing borewell for Supplying & installation of Motor Pump, Cable & other necessaries material & Laying of pipeline Laying of HDPI Pipeline, Laying of PVC Pipeline in Kolar CMC limit | 14823409.78 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3782021 | 142865 | None | code01 | Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. etc. complete(BWSSDB SR 2023-24, V-05, Pg no:153,Item code : 13.15.7)7.50 HP - 90 LPM @ 165 m = 16 STG Outlet Dia - 2.00" | Each | 42034.3 | 42034.3 | 1.0 | False | None | None | False | None | False | 42034.3 | 0 | 3782022 | 142865 | None | code02 | Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. etc. complete(BWSSDB SR 2023-24, V-05, Pg no:153,Item code : 13.20.5)20.00 HP - 135 LPM @ 350 m = 25 STG Outlet Dia - 2.00" | Each | 83522.7 | 83522.7 | 27.0 | False | None | None | False | None | False | 2255112.9 | 0 | 3782023 | 142865 | None | code03 | Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. etc. complete (BWSSDB SR 2023-24, V-05, Pg no:153,Item code : 13.21.5) 25.00 HP - 135 LPM @ 420 m = 30 STG Outlet Dia - 2.00 | Each | 85097.57 | 85097.57 | 1.0 | False | None | None | False | None | False | 85097.57 | 0 | 3782024 | 142865 | None | code04 | Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For: GI Pipe etc. complete.(BWSSDB SR 2023-24, V-05, Pg no:128 ,Item code : 11.2.6) Medium Duty GI pipe of 50mm dia | Mtr | 601.52 | 601.52 | 7120.0 | False | None | None | False | None | False | 4282822.4 | 0 | 3782025 | 142865 | None | code05 | Supplying and drawing 3 core flat PVC sheathed submersible pumpcable manufactured with electrolytic grade copper with flexible copperwith low resistance conductor confirming to13:8130-1984 and virgingrade PVC insulation and powder coating extruded PVC sheathedsuitable for working voltage upto 1100 Volts as per IS-694:1990.(BESCOM SR 2023-24, V-06,Pg No:02, Item No:-2.6.3)3C x 6 mm2 | Mtr | 252.35 | 252.35 | 12620.0 | False | None | None | False | None | False | 3184657.0 | 0 | 3782026 | 142865 | None | code06 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.(BWSSDB SR 2023-24, V-5, Pg No:156, Code:13.32) | Job | 6695.0 | 6695.0 | 29.0 | False | None | None | False | None | False | 194155.0 | 0 | 3782027 | 142865 | None | code07 | Supply, installing,testing andcommissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete.(BWSSDB SR 2023-24, V-05, Pg no:155 ,Item code :13.24.3) 6 to 15 HP pumps | Each | 18025.0 | 18025.0 | 26.0 | False | None | None | False | None | False | 468650.0 | 0 | 3782028 | 142865 | None | code08 | Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work. (BWSSDB SR 2023-24, V-05, Pg no:156 ,Item code : 13.34) | Each | 1493.5 | 1493.5 | 25.0 | False | None | None | False | None | False | 37337.5 | 0 | 3782029 | 142865 | None | code09 | Fabricating supplying and mounting MS box made out ....SWGsuitable for floor /wall mounting, fully weather proof with provisionfor better heat dissipation, provided with hinged front cover,equipped with tamper proof locking arrangements, with suitablesize clamps with necessary cable entry pipe with gland and boxshould be finished with 7tanks treatment with powder coated paintand finally finished with approved colour etc., complete.(PWD ELE SR 2023-24, V-6, Pg No:20, Code:5.42.2)16 SWG | Sq CM | 0.44 | 0.44 | 324000.0 | False | None | None | False | None | False | 142560.0 | 0 | 3782030 | 142865 | None | code10 | Supplying & fixing of Porcelain fuse channel with cut out onexisting wooden/panel using necessary nuts, bolts and washers.(PWD ELE SR 2023-24, V-6, Pg No:14, Code:5.7.5, )200 A | Each | 1471.87 | 1471.87 | 81.0 | False | None | None | False | None | False | 119221.47 | 0 | 3782031 | 142865 | None | code11 | Wiring for lighting/power circuit using one of FRLS PVC insulated1100V grade, multistrand copper wire with low conductor resistancesingle core in open or concealed system of wiring with specified IS 694:2010(PWD ELE SR 2023-24, V-6, Pg No:05, Code:2.3.6 )10 mm2 | Mtr | 172.01 | 172.01 | 198.0 | False | None | None | False | None | False | 34057.98 | 0 | 3782032 | 142865 | None | code12 | 16 Sqmm Aluminium Single Core/Multi Core of Grade 650/1100V (BESCOM SR 2021-22, Part :- 05 , Pg No:- 17, SL NO:-3) | Mtr | 42.18 | 42.18 | 900.0 | False | None | None | False | None | False | 37962.0 | 0 | 3782033 | 142865 | None | code13 | Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments. (BWSSDB 2023-24 SR RATE Pg no:154,code: 13.25.1).Size 50mm | Each | 1287.5 | 1287.5 | 26.0 | False | None | None | False | None | False | 33475.0 | 0 | 3782034 | 142865 | None | code14 | Supply and delivery at site wrought middle steel (galvanized) GI elbow confirming to IS 1239-II, 1991 with latest amendments if any for: (BWSSDB SR 2023-24 Pg no:129,code:- 11.7.6).For 50 mm dia GI elbow | Each | 275.01 | 275.01 | 51.0 | False | None | None | False | None | False | 14025.51 | 0 | 3782035 | 142865 | None | code15 | Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments(BWSSDB SR 2023-24 Vol-5,P. No:154, I.No:13.24.3)Size 80mm | Each | 1699.5 | 1699.5 | 2.0 | False | None | None | False | None | False | 3399.0 | 0 | 3782036 | 142865 | None | code16 | Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments(BWSSDB SR 2023-24 Vol-5,P. No:154, I.No:13.24.1)Size 50mm | Each | 1287.5 | 1287.5 | 46.0 | False | None | None | False | None | False | 59225.0 | 0 | 3782037 | 142865 | None | code17 | Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments(BWSSDB SR 2023-24 Vol-5,P. No:154, I.No:13.24.2)Size 65mm | Each | 1493.5 | 1493.5 | 12.0 | False | None | None | False | None | False | 17922.0 | 0 | 3782038 | 142865 | None | code18 | Providing wrought mild steel (galvanized) GI collar confirming to IS 1239-II, 1991 with latest amendments if any.(BWSSDB SR 2023-24 Vol-5,P. No:129 , I.No:11.6.6)For 50 mm dia GI collar: | Each | 275.01 | 275.01 | 1033.0 | False | None | None | False | None | False | 284085.33 | 0 | 3782039 | 142865 | None | code19 | Cutting Asphalt /Concrete road surface using machine cutter for leakage pit with earth work excavation in all classifications of soil including all lead and lifts bailing out water with pumps including barricading, danger lighting etc., as per requirement and disposing of the excavated stuff as directed. After attending the leak, refilling the trench for 30 cm depth quarry dust above and around pipelines and balance with available earth in layers not exceeding 20 cms in depth, compacting Each deposited layer by ramming including watering and consolidation by mechanical means approved by Engineer Incharge. (Work to be carried out as per leak repair manual and the rate includes hire charges of dewatering Pump, tractor, Jeep with all kinds of Labour in a Complete manner).(BWSSDB SR 2023-24, V-5,Pg No:- 48, Item No:-3.3) | Cum | 1191.71 | 1191.71 | 254.1 | False | None | None | False | None | False | 302813.511 | 0 | 3782040 | 142865 | None | code20 | Earth work excavation for pipelines/cables by Manual means upto 600mm trench width, as per drawing and technical specifications, includingsetting out, shoring, strutting, barricading, caution lights, removal ofstumps and other deleterious matter, including dressing of excavatedsurfaces, disposing off or leveling the excavated earth or sorting& stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides offoundations etc. in layers not exceeding 20cm in depth, consolidatingeach deposited layer by ramming and watering and lift upto 1.5 mincluding cost of labour, tools, usage& other appurtenances requiredto complete the work.(PWD SR 2023-24, V-1, Pg No: 6,Item Code:1.6.1)In all kinds of soils. Depth upto 1.50m | Cum | 498.52 | 498.52 | 1605.2625 | False | None | None | False | None | False | 800255.4615 | 0 | 3782041 | 142865 | None | code21 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc.(BWSSDB SR 2023-24, V-5, Pg No:113, Item code:10.1.4) PVC PIPES 63MM DIA, 6KG/SQCM & CLASS3 | Mtr | 165.83 | 165.83 | 1450.0 | False | None | None | False | None | False | 240453.5 | 0 | 3782042 | 142865 | None | code22 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc.(BWSSDB SR 2023-24, V-5, Pg No:113, Item code:10.1.6) PVC pipes 90mm dia., 6 kg/sqcm & class 5 | Mtr | 302.82 | 302.82 | 745.0 | False | None | None | False | None | False | 225600.9 | 0 | 3782043 | 142865 | None | code23 | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0(BWSSDB SR 2023-24, V-05, Pg No:95 ,Item Code:9.1.1) HDPE Grade PE80-PN6.0, 63mm dia | Mtr | 194.67 | 194.67 | 198.0 | False | None | None | False | None | False | 38544.66 | 0 | 3782044 | 142865 | None | code24 | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0(BWSSDB SR 2023-24, V-05, Pg No:95 ,Item Code:9.1.2) HDPE Grade PE80-PN6.0, 75mm dia | Mtr | 252.35 | 252.35 | 1108.0 | False | None | None | False | None | False | 279603.8 | 0 | 3782045 | 142865 | None | code25 | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0(BWSSDB SR 2023-24, V-05, Pg No:95 ,Item Code:9.1.3) HDPE Grade PE80-PN6.0, 90mm dia | Mtr | 330.63 | 330.63 | 390.0 | False | None | None | False | None | False | 128945.7 | 0 | 3782046 | 142865 | None | code26 | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used. For :HDPE PE 80 PN 6.0 160MM DIA(BWSSDB SR 2023-24, V-05, Pg No:95 ,Item Code:9.1.7) | Mtr | 987.77 | 987.77 | 799.0 | False | None | None | False | None | False | 789228.23 | 0 | 3782047 | 142865 | None | code27 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. (PWD SR 2023-24, V-II, Pg No:-26, Item Code:-4.17) | Cum | 2635.77 | 2635.77 | 17.55 | False | None | None | False | None | False | 46257.7635 | 0 | 3782048 | 142865 | None | code28 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. Thegranite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) (PWD SR 2023-24, V-1, Pg No:-15, Item Code:2.1.6) Mix 1:2:4 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6430.29 | 6430.29 | 99.9 | False | None | None | False | None | False | 642385.971 | 0 | 3782049 | 142865 | None | code29 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cm in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5m. Including cost of all labour complete as per specifications (PWD SR 2023-24, V-II, Pg No:-26, Item Code:-4.17) | Cum | 164.8 | 164.8 | 203.4 | False | None | None | False | None | False | 33520.32 | 0 |
|