tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1725451154000 | 0 | None | None | Buildings | Construction to medicine Storeroom at DD veterinary compound i n Belagavi City in Belagavi District. | 4033295.56 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3920823 | 151228 | None | code01 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work (PWD CSR V-1 2023-24 / P.No. 8 I.No.1.12)with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 99.75 | 99.75 | 43.198 | False | None | None | False | None | False | 4309.0005 | 0 | 3920824 | 151228 | None | code02 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & otherappurtenaces required to complete the work.In all kinds of soils Depth upto 1.5 m (PWD CSR V-1 2023-24 / P.No. 5 I.No.1.4.1)with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Cum | 254.1 | 254.1 | 74.951 | False | None | None | False | None | False | 19045.0491 | 0 | 3920825 | 151228 | None | code03 | Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications.(PWD CSR V-1 2023-24 / P.No. 11.No.1.23) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Cum | 2816.1 | 2816.1 | 22.8878 | False | None | None | False | None | False | 64454.33358 | 0 | 3920826 | 151228 | None | code04 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:5:10 (M5)Using 40 mm nominal size graded crushed coarse aggregates(PWD CSR V-1 2021-22 / P.No. 15 I.No.2.1.1)with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Cum | 5604.9 | 5604.9 | 22.6878 | False | None | None | False | None | False | 127162.85022 | 0 | 3920827 | 151228 | None | code05 | Providing Random rubble masonry with hard stone in foundation andplinth including levelling up with cement concrete 1:6:12 (1 cement : 6coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinthlevel with Cement mortar 1:6 (1 cement : 6 coarse sand (PWD SR V-2 2023-24 / P.No. 9I.No.5.1)with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Cum | 5891.55 | 5891.55 | 22.04 | False | None | None | False | None | False | 129849.762 | 0 | 3920828 | 151228 | None | code06 | Providing ruled pointing to cursed stone masonry with lime mortar 1:3, 20mm deep, after raking joints to depth of 20mm nicely lining, including cost all materials, labour, usage charges of machinery, curing complete as pre specification(PWD SR V-2 2023-24 / P.No. 190 I.No.21.10)with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Sqm | 313.95 | 313.95 | 32.49 | False | None | None | False | None | False | 10200.2355 | 0 | 3920829 | 151228 | None | code07 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork to be paid separately)-M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR V-1 2023-24 / P.No. 15 I.No.2.2.1)with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Cum | 7129.46 | 7129.46 | 10.9073 | False | None | None | False | None | False | 77763.159058 | 0 | 3920830 | 151228 | None | code08 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. Thegranite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR V-1 2023-24 / P.No. 17 I.No.2.4.1) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Cum | 11431.14 | 11431.14 | 2.707 | False | None | None | False | None | False | 30944.09598 | 0 | 3920831 | 151228 | None | code09 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(PWD CSR V-1 2021-22 / P.No.7 I.No.1.9) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work.with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . . | Cum | 279.3 | 279.3 | 36.69 | False | None | None | False | None | False | 10247.517 | 0 | 3920832 | 151228 | None | code10 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. Thegranite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR V-1 2023-24 / P.No. 17 I.No.2.4.1)with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Cum | 10086.3 | 10086.3 | 5.8745 | False | None | None | False | None | False | 59251.96935 | 0 | 3920833 | 151228 | None | code11 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR V-1 2021-22 / P.No. 17 I.No.2.5.1) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Cum | 11834.55 | 11834.55 | 12.583 | False | None | None | False | None | False | 148914.14265 | 0 | 3920834 | 151228 | None | code12 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR V-1 2021-22 / P.No. 17 I.No.2.5.1)with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Cum | 11138.4 | 11138.4 | 18.835 | False | None | None | False | None | False | 209791.764 | 0 | 3920835 | 151228 | None | code13 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR V-1 2021-22 / P.No. 17 I.No.2.5.1) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Cum | 10442.25 | 10442.25 | 33.3155 | False | None | None | False | None | False | 347888.779875 | 0 | 3920836 | 151228 | None | code14 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(PWD CSR V-1 2021-22 / P.No. 17 I.No.2.5.1)with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Cum | 10094.18 | 10094.18 | 1.2488 | False | None | None | False | None | False | 12605.611984 | 0 | 3920837 | 151228 | None | code15 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.(PWD CSR V-1 2023-24 / P.No.11 I.No.1.11)with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Cum | 454.65 | 454.65 | 162.05 | False | None | None | False | None | False | 73676.0325 | 0 | 3920838 | 151228 | None | code16 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.(PWD SR V-2 2023-24 / P.No. 1 I.No.6.8) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Cum | 8367.45 | 8367.45 | 46.1765 | False | None | None | False | None | False | 386379.554925 | 0 | 3920839 | 151228 | None | code17 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Building (PWD SR V-1 2023-24 / P.No. 18 I.No.2.11 a) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Kg | 93929.85 | 93929.85 | 10.94 | False | None | None | False | None | False | 1027592.559 | 0 | 3920840 | 151228 | None | code18 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(PWD SR V-2 22023-24 / P.No. 41 I.No.8.1.1)with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Sqm | 267.75 | 267.75 | 414.79 | False | None | None | False | None | False | 111060.0225 | 0 | 3920841 | 151228 | None | code19 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge(PWD SR V-2 2023-24 / P.No. 42 I.No.8.8)with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Sqm | 389.55 | 389.55 | 463.6 | False | None | None | False | None | False | 180595.38 | 0 | 3920842 | 151228 | None | code20 | Flooring with 25mm thick polished tandur blue stone slabs using cementmortar 1:6, 25mm thick over existing cement concrete bed or top of rooflaid to line and level and jointed with cement slurry mixed with pigmentto match the shade of the slab, , including cost of materials, labour, curing,polishing complete as per specifications. (PWD SR V-2 2023-24 / P.No. 64 I.No.9.34)with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Sqm | 1622.25 | 1622.25 | 173.5275 | False | None | None | False | None | False | 281504.986875 | 0 | 3920843 | 151228 | None | code21 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(PWD SR V-2 23-24/ P.No. 50 I.No.8.51)with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Sqm | 105.0 | 105.0 | 349.57 | False | None | None | False | None | False | 36704.85 | 0 | 3920844 | 151228 | None | code22 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC (Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and ead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 50mm width x 42mmheight with reinforcement of 1mm thickness and Sash with overall size of 31mm X 57mm with Gi reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 21.5mm x 9.5 mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 1.8-0.2 mm. Maximum possible size 1519mm x 1519mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) )(PWD CSR V-2 2023-24 / P.No.110 I.No.12.86)with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Sqm | 5659.5 | 5659.5 | 15.84 | False | None | None | False | None | False | 89646.48 | 0 | 3920845 | 151228 | None | code23 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding(PWD SR V-2 2023-24 / P.No. 85 I.No.11.34A)with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Kg | 110.25 | 110.25 | 332.64 | False | None | None | False | None | False | 36673.56 | 0 | 3920846 | 151228 | None | code24 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade:New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt,dust,mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(PWD SR V-2 2023-24 / P.No. 45 I.No.8.25)with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Sqm | 143.85 | 143.85 | 349.57 | False | None | None | False | None | False | 50285.6445 | 0 | 3920847 | 151228 | None | code25 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR V-2 2023-24 / P.No. 45 I.No.8.25)with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Sqm | 55.65 | 55.65 | 419.35 | False | None | None | False | None | False | 23336.8275 | 0 | 3920848 | 151228 | None | code26 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67L/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.(PWD SR V-2 2023-24 / P.No. 45 I.No.8.30)with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Sqm | 182.7 | 182.7 | 419.35 | False | None | None | False | None | False | 76615.245 | 0 | 3920849 | 151228 | None | code27 | Supplying and fixing rolling shutters of approved make, made of requiredsize M.S. laths, interlocked together through their entire length andjointed together at the end by end locks, mounted on speciallydesigned pipe shaft with brackets, side guides and arrangements forinside and outside locking with push and pull operation complete,including the cost of providing and fixing necessary 27.5 cm long wiresprings manufactured from high tensile steel wire of adequate strengthconforming to IS: 4454 - part 1 and M.S. top cover of required thicknessfor rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top coverincluding cost of materials, labour, usage charges of machinery completeas per specifications and as per directions of the Engineer-in-Charge. )(PWD SR V-2 2023-242 / P.No. 100 I.No.11.6.1)with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Sqm | 2764.65 | 2764.65 | 12.6 | False | None | None | False | None | False | 34834.59 | 0 | 3920850 | 151228 | None | code28 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-charge. (PWD SR V-2 2023-24 / P.No.77 I.No.11.5.2)with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Sqm | 4454.1 | 4454.1 | 2.982 | False | None | None | False | None | False | 13282.1262 | 0 | 3920851 | 151228 | None | code29 | Painting (one coats) with black Japan paint of approved brand and manufacture to give an even shade. including preparing the surface after thoroughly cleaning the surface to remove all dirt, dust and foreign matter , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge..(PWD SR 2023-24, I.No.8.70)with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Sqm | 71.4 | 71.4 | 41.64 | False | None | None | False | None | False | 2973.096 | 0 | 3920852 | 151228 | None | code30 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 m² over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR V-2 2023-24 / P.No. 47 I.No.8.33.3)with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Sqm | 145.95 | 145.95 | 41.64 | False | None | None | False | None | False | 6077.358 | 0 | 3920853 | 151228 | None | code31 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (PWD SR V-2 2023-24 / P.No.82 I.No.11.16.1) with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Kg | 142.8 | 142.8 | 158.21 | False | None | None | False | None | False | 22592.388 | 0 | 3920854 | 151228 | None | code32 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.m2 568.007.39 (PWD SR V-2 2023-24 / P.No. 26 I.No.7.38)with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Sqm | 596.4 | 596.4 | 11.45 | False | None | None | False | None | False | 6828.78 | 0 | 3920855 | 151228 | None | code33 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes of 150mm dia conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. (PWD SR V-2 2023-24/ P.No. 125 I.No.13.49)with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Cum | 596.4 | 596.4 | 16.0 | False | None | None | False | None | False | 9542.4 | 0 | 3920856 | 151228 | None | code34 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer in-charge. 19.9.2 In cement mortar (PWD SR V-2 2023-24 / P.No. 187 I.No.19.9.2)with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Cum | 1768.2 | 1768.2 | 162.855 | False | None | None | False | None | False | 287960.211 | 0 | 3920857 | 151228 | None | code35 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the ma terial to the appropriate disposal area as per direction of engineer inc harge (PWD SR V-2 2023-24 / P.No. 189 with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. . | Sqm | 53.55 | 53.55 | 424.0 | False | None | None | False | None | False | 22705.2 | 0 |
| 1725451154000 | 0 | None | None | Buildings | Electrical estimate | 165635.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3920858 | 151229 | None | code01 | Supplying heavy gauge PVC conduit pipe mm diamm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Rmtr | 78.0 | 78.0 | 402.0 | False | None | None | False | None | False | 31356.0 | 0 | 3920859 | 151229 | None | code02 | Supplying heavy gauge PVC Conduit Pipe dia mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Rmtr | 79.0 | 79.0 | 402.0 | False | None | None | False | None | False | 31758.0 | 0 | 3920860 | 151229 | None | code03 | Supplying and fixing PVC metal conduit Deep junction box with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Rmtr | 56.0 | 56.0 | 402.0 | False | None | None | False | None | False | 22512.0 | 0 | 3920861 | 151229 | None | code04 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete.with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 112.0 | 112.0 | 6.0 | False | None | None | False | None | False | 672.0 | 0 | 3920862 | 151229 | None | code05 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 86.0 | 86.0 | 6.0 | False | None | None | False | None | False | 516.0 | 0 | 3920863 | 151229 | None | code06 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete.with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 74.0 | 74.0 | 2.0 | False | None | None | False | None | False | 148.0 | 0 | 3920864 | 151229 | None | code07 | Point wiring using Copper wire with switch Supplying and wiring adopting loop system in existing PVC Conduit casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Point | 285.0 | 285.0 | 6.0 | False | None | None | False | None | False | 1710.0 | 0 | 3920865 | 151229 | None | code08 | Point wiring using Copper wire with switch Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Point | 394.0 | 394.0 | 6.0 | False | None | None | False | None | False | 2364.0 | 0 | 3920866 | 151229 | None | code09 | Point wiring using Copper wire with switch Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2 X1.5Sq.mm Cable confirming to the GTP, with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. GROUP A with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Point | 570.0 | 570.0 | 6.0 | False | None | None | False | None | False | 3420.0 | 0 | 3920867 | 151229 | None | code10 | Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Rmtr | 26.0 | 26.0 | 60.0 | False | None | None | False | None | False | 1560.0 | 0 | 3920868 | 151229 | None | code11 | Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Rmtr | 42.0 | 42.0 | 50.0 | False | None | None | False | None | False | 2100.0 | 0 | 3920869 | 151229 | None | code12 | Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. )with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Rmtr | 92.0 | 92.0 | 60.0 | False | None | None | False | None | False | 5520.0 | 0 | 3920870 | 151229 | None | code13 | Supplying and mounting 2 Nos. of 2 way 6 amps flush type switches either surface/flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as per IS 1293 with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 170.0 | 170.0 | 10.0 | False | None | None | False | None | False | 1700.0 | 0 | 3920871 | 151229 | None | code14 | Supplying and mounting 2 Nos. of 2 way 6 amps flush type switches either surface flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush Supplying and fixing PBBC/Bakelite straight or slant batten holder and wiring with 60w230 volts lamps. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 78.0 | 78.0 | 8.0 | False | None | None | False | None | False | 624.0 | 0 | 3920872 | 151229 | None | code15 | Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc., and fixing on existing wooden or metal box using N.F. screws with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Sqm | 0.41 | 0.41 | 1200.0 | False | None | None | False | None | False | 492.0 | 0 | 3920873 | 151229 | None | code16 | Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:37419 and also comply with IS: 17091984 with latest amendment, Rated voltage 220 V 50 Hz, Rated power upto 35 W - Rated current As per IS:37419, Rated power factor 0.9 lagging(min), Rated speed 350 0 RPM, Rated air delivery 210 - 10 Cubic Meter Minimum, Rated service value 6.2 CMM W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:3742019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 48 Sweep 5 Star (1200 mm) )with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work | Each | 2984.0 | 2984.0 | 10.0 | False | None | None | False | None | False | 29840.0 | 0 | 3920874 | 151229 | None | code17 | Extra length of GI pipe of class B 19mm dia for down rod. ( )with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Rmtr | 197.0 | 197.0 | 10.0 | False | None | None | False | None | False | 1970.0 | 0 | 3920875 | 151229 | None | code18 | Supplying of feet -PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.11.3.2 LED light fitting 1 x 4' - 20/22 W with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 690.0 | 690.0 | 14.0 | False | None | None | False | None | False | 9660.0 | 0 | 3920876 | 151229 | None | code19 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 3088.0 | 3088.0 | 2.0 | False | None | None | False | None | False | 6176.0 | 0 | 3920877 | 151229 | None | code20 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 415.0 | 415.0 | 3.0 | False | None | None | False | None | False | 1245.0 | 0 | 3920878 | 151229 | None | code21 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 739.0 | 739.0 | 2.0 | False | None | None | False | None | False | 1478.0 | 0 | 3920879 | 151229 | None | code22 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit … The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Nos | 3510.0 | 3510.0 | 2.0 | False | None | None | False | None | False | 7020.0 | 0 | 3920880 | 151229 | None | code23 | Supplying and running GICopper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas spacers etc. GI Wire )with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Rmtr | 19.0 | 19.0 | 10.0 | False | None | None | False | None | False | 190.0 | 0 | 3920881 | 151229 | None | code24 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. (Elec SR - 2022-23 - Item No. - 5.7.3 )(Page No. - 44 )with all lead, lifts, loading & unloading charges including cost and conveyance of all materials, labour, equipments and other incidental charges required for successfull completion of work etc., complete as per specifications and as per the directions of the Engineer incharge of the work. | Each | 401.0 | 401.0 | 4.0 | False | None | None | False | None | False | 1604.0 | 0 |
|
|
---|