createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1725361084123
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee2480.00
emd99000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose17-09-2024 16:30:00
tenderQueryClose14-09-2024 16:30:00
technicalBidOpen18-09-2024 17:00:00
publishedDate05-09-2024 15:55:11
publishedByPostCMC_MCOM_DND
publishedByUserKPE11906 - RAJARAM S PAWAR
bidValidityPeriod90
noOfCalls1
preBidMeetingDate13-09-2024 11:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonMr. VS Kulkarni
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9986615078
tenderSupplierListNone
tenderSchedule
createdTs1725361084149
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/BD/WORK_INDENT21084
titleConstructionn Proposed 08 TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY SHED) SWM site At Dandeli
descriptionConstructionn Proposed 08 TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY SHED) SWM site At Dandeli
categoryWORKS
categoryTextWorks
ecv9896612.27
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2417
locationNameDMA City Municipal Council Dandeli
provisionalAmount9900000.0
groupOverheadTotal1509652.72
fileNumberCMC/DND/TECH/SBM2-0/JE/1
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17253610840000NoneNoneBuildingsConstructionn Proposed 08 TPD MRF Centre (Material Recovery Facility) of PEB Structure (PRIMARY SHED) SWM site At Dandeli8386959.55
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3907828150711NoneItem No. 1.4.1 Page No.5 Vol.1 PWD SREarth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum249.26249.26104.82FalseNoneNoneFalseNoneFalse26127.43320
3907829150711NoneItem No. 2.1.3 Page No. 15 Vol.1 PWD SRProviding and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6168.676168.6791.49FalseNoneNoneFalseNoneFalse564371.61830
3907830150711NoneItem No. 2.1.4 Page No. 15 Vol.1 PWD SRProviding and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum6838.326838.32114.26FalseNoneNoneFalseNoneFalse781346.44320
3907831150711NoneItem No. 2.3.2 Page No. 16 Vol.1 PWD SRVol-1 Item Code :2.3.2 P.No:16 Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum9789.129789.129.99FalseNoneNoneFalseNoneFalse97793.30880
3907832150711NoneItem No. 2.11 Page No. 18 Vol.1 PWD SRSteel Fabrication: Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening,cutting, bending, hooking, laping/welding joints, tying with binding wire / softannealed steel wire and other ancilary operations complete as per drawing and technical specificationt92140.7192140.719.76FalseNoneNoneFalseNoneFalse899293.32960
3907833150711NoneItem No. 5.4 Page No. 9 Vol.2 PWD SR)Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6580.676580.6747.45FalseNoneNoneFalseNoneFalse312252.79150
3907834150711NoneItem No. 1.8 Page No. 7 Vol.1 PWD SRConstruction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the workCum474.0474.0524.57FalseNoneNoneFalseNoneFalse248646.180
3907835150711NoneItem No. 6.33 Page No. 17 Vol.2 PWD SRProviding and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1267.931267.9328.49FalseNoneNoneFalseNoneFalse36123.32570
3907836150711NoneItem No. 8.3.1, Page No. 41, Vol.2Providing 15mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm303.85303.85412.42FalseNoneNoneFalseNoneFalse125313.8170
3907837150711NoneItem No. 11.2, Page No. 77, Vol.2Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inChargeKgs116.39116.3929155.0FalseNoneNoneFalseNoneFalse3393350.450
3907838150711NoneItem No. 7.38, Page No. 26, Vol.2Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.Sqm585.04585.041290.23FalseNoneNoneFalseNoneFalse754836.15920
3907839150711NoneItem No. 8.51, Page No. 50, Vol.2Providing and applying white cement based putty of average thickness1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in chargeSqm103.0103.0412.41FalseNoneNoneFalseNoneFalse42478.230
3907840150711NoneItem No. 8.54.1, Page No. 50, Vol.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in charge.Sqm75.1975.19205.91FalseNoneNoneFalseNoneFalse15482.37290
3907841150711NoneItem No. 8.54.1, Page No. 50, Vol.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. One coat as per specifications and as per directions of Engineer in chargeSqm75.1975.19188.69FalseNoneNoneFalseNoneFalse14187.60110
3907842150711NoneItem No. 11.6.1, Page No. 76, Vol.2Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm2711.992711.9967.5FalseNoneNoneFalseNoneFalse183059.3250
3907843150711NoneItem No. 11.8.4, Page No. 77, Vol.2Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.No25426.5825426.583.0FalseNoneNoneFalseNoneFalse76279.740
3907844150711NoneItem No. 11.35.1.1, Page No. 87, Vol.2Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specificationsKg465.56465.56480.0FalseNoneNoneFalseNoneFalse223468.80
3907845150711NoneVol-1 Item Code :2.3.2 P.No:16Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11346.4811346.489.11FalseNoneNoneFalseNoneFalse103366.43280
3907846150711NoneVOL -6 SR 2023-24 ITEM NO.1.1.1Supplying heavy gauge PVC conduit pipe . dia . mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.m69.069.0300.0FalseNoneNoneFalseNoneFalse20700.00
3907847150711NoneVOL -6 SR 2023-24 ITEM NO.1.5.1Supplying and fixing PVC/metal conduit Deep junction boxEach49.049.025.0FalseNoneNoneFalseNoneFalse1225.00
3907848150711NoneVOL -6 SR 2023-24 ITEM NO.1.11Supplying And Fixing "S" Hook made out of 14 mm dia M.S.Rod.No52.052.03.0FalseNoneNoneFalseNoneFalse156.00
3907849150711NoneVOL -6 SR 2023-24 ITEM NO.2.1.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switchPoint285.0285.010.0FalseNoneNoneFalseNoneFalse2850.00
3907850150711NoneVOL -6 SR 2023-24 ITEM NO.2.1.2Supplying and wiring adopting loop system in existing PVCConduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to out let via switchPoint394.0394.05.0FalseNoneNoneFalseNoneFalse1970.00
3907851150711NoneVOL -6 SR 2023-24 ITEM NO.2.1.3Supplying and wiring adopting loop system in existing PVCConduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to out let via switchPoint570.0570.05.0FalseNoneNoneFalseNoneFalse2850.00
3907852150711NoneVOL -6 SR 2023-24 ITEM NO.3.4.3Supplying and fixing surface/flush mounting unbreakable PVCmodular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs,Machine/NF screws etc., complete.EEach177.0177.05.0FalseNoneNoneFalseNoneFalse885.00
3907853150711NoneVOL -6 SR 2023-24 ITEM NO.3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC boxEach175.0175.05.0FalseNoneNoneFalseNoneFalse875.00
3907854150711NoneVOL -6 SR 2023-24 ITEM NO 3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16A Universal SocketEach236.0236.05.0FalseNoneNoneFalseNoneFalse1180.00
3907855150711NoneVOL -6 SR 2023-24 ITEM NO.3.6.9Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32A DP SwitchEach326.0326.05.0FalseNoneNoneFalseNoneFalse1630.00
3907856150711NoneVOL -6 SR 2023-24 ITEM NO.3.8Supplying 4mm thick plastic sheet with necessary nitches forfixing switches, regulators etc, and fixing on existing wooden ormetal box using N.F. screws2 Cmtr0.410.411000.0FalseNoneNoneFalseNoneFalse410.00
3907857150711NoneVOL -6 SR 2023-24 ITEM NO. 5.4.3Fixing a shunt capacitor of . kVAR capacity with necessary clamps,bolts, and nuts on existing wooden or metal board including banking of more than one capacitor 11 to 20 KvarEach344.0344.03.0FalseNoneNoneFalseNoneFalse1032.00
3907858150711NoneVOL -6 SR 2023-24 ITEM NO.5.12.4Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution)Each15249.015249.01.0FalseNoneNoneFalseNoneFalse15249.00
3907859150711NoneVOL -6 SR 2023-24 ITEM NO.5.13.7Supply and fixing of 3pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 200 AEach20012.020012.04.0FalseNoneNoneFalseNoneFalse80048.00
3907860150711NoneVOL -6 SR 2023-24 ITEM NO. 5.14.10Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947 200 AEach39118.039118.04.0FalseNoneNoneFalseNoneFalse156472.00
3907861150711NoneVOL -6 SR 2023-24 ITEM NO. 5.15.12Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts,necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 . (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism 200 A 25kA FOUR PoleEach17301.017301.01.0FalseNoneNoneFalseNoneFalse17301.00
3907862150711NoneVOL -6 SR 2023-24 ITEM NO.5.16Supplying and fixing of Shunt trip suitable for MCCB.CBCTEach1703.01703.01.0FalseNoneNoneFalseNoneFalse1703.00
3907863150711NoneVOL -6 SR 2023-24 ITEM NO.5.18.9Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 50-63 A TPNEach3088.03088.04.0FalseNoneNoneFalseNoneFalse12352.00
3907864150711NoneVOL -6 SR 2023-24 ITEM NO.5.21Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel boardEach9255.09255.01.0FalseNoneNoneFalseNoneFalse9255.00
3907865150711NoneVOL -6 SR 2023-24 ITEM NO. 5.33Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracyEach9315.09315.01.0FalseNoneNoneFalseNoneFalse9315.00
3907866150711NoneVOL -6 SR 2023-24 ITEM NO.5.34Supplying, fixing and wiring 50/5 to 400/5A 5VA burden Current Transformer Class 0.5 accuracy with Tape Wound.Each562.0562.01.0FalseNoneNoneFalseNoneFalse562.00
3907867150711NoneVOL -6 SR 2023-24 ITEM NO.5.37Supplying, fixing and wiring heavy duty low voltage capacitorsconforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor.Kvar480.0480.01.0FalseNoneNoneFalseNoneFalse480.00
3907868150711NoneVOL -6 SR 2023-24 ITEM NO. 5.38Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each515.0515.03.0FalseNoneNoneFalseNoneFalse1545.00
3907869150711NoneVOL -6 SR 2023-24 ITEM NO.5.39Supplying, fixing and wiring Automatic Power Factor controller circuit unit fully, static units controlled by 14 stage microprocessor operation, relays LED display, self programming function for power stages and operating logic checking facility for healthy and efficient of each individual capacitor bank, measurement of network harmonics with indication when limit values are exceeded, Comprehensive displays with large, three phase LED display, Long term memory for settings, protection for over voltage, power factor correction fault and no voltage, to connect/ disconnect banks, with automatic recognition or with standard programsEach21640.021640.01.0FalseNoneNoneFalseNoneFalse21640.00
3907870150711NoneVOL -6 SR 2023-24 ITEM NO. 5.40.2Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 30 x 10 mm Aluminium Stripsm3435.03435.010.0FalseNoneNoneFalseNoneFalse34350.00
3907871150711NoneVOL -6 SR 2023-24 ITEM NO.5.41.5Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. Flat.with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint 75 x 150 x 75 x 6 mm C channelm926.0926.010.0FalseNoneNoneFalseNoneFalse9260.00
3907872150711NoneVOL -6 SR 2023-24 ITEM NO.5.42.1Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete 14 SWG2 Cmtr0.50.530000.0FalseNoneNoneFalseNoneFalse15000.00
3907873150711NoneVOL -6 SR 2023-24 ITEM NO. 6.4.2Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans 56" Sweep 5 Star (1400 mm)Each3754.03754.02.0FalseNoneNoneFalseNoneFalse7508.00
3907874150711NoneVOL -6 SR 2023-24 ITEM NO. 11.6.1Supplying of recess mounting non integral type . LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. LED modular down light 1x1 18WEach3138.03138.05.0FalseNoneNoneFalseNoneFalse15690.00
3907875150711NoneVOL -6 SR 2023-24 ITEM NO. 11.3.2Supplying of .feet -PVC Batten with integrated LED tube . W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition LED light fitting 1 x 4' - 20/22 WEach690.0690.05.0FalseNoneNoneFalseNoneFalse3450.00
3907876150711NoneVOL -6 SR 2023-24 ITEM NO 13.17.3Fixing a shunt capacitor of . kVAR capacity with necessary clamps, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor. 11 to 20kVAREach122.0122.012.0FalseNoneNoneFalseNoneFalse1464.00
3907877150711NoneVOL -6 SR 2023-24 ITEM NO 13.17.3Fixing a shunt capacitor of . kVAR capacity with necessary clamps, bolts, and nuts on existing wooden or metal board including banking of more than one capacitor. 11 to 20kVAREach410.0410.01.0FalseNoneNoneFalseNoneFalse410.00
3907878150711NoneVOL -6 Hescom SR 2023-24 ITEM NO 32.10 1.1kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 35 Sqmm, 4 Core, (15 GI Strips - 4 x 0.8 mm) .Km176070.0176070.00.1FalseNoneNoneFalseNoneFalse17607.00
3907879150711NoneVOL -6 Hescom SR 2023-24 ITEM NO 32.12 1.1kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 50 Sqmm, 4 Core, (17 GI Strips - 4 x 0.8 mm)Km207192.0207192.00.1FalseNoneNoneFalseNoneFalse20719.20
3907880150711NoneVOL -6 Hescom SR 2023-24 ITEM NO 51.01,51.02Grounding Material GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 K, Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg eachNo1419.01419.01.0FalseNoneNoneFalseNoneFalse1419.00
3907881150711NoneVOL -6 Hescom SR 2023-24 ITEM NO 51.03Grounding Material Good Quality Salt for grounding purposes packed in 50 Kg gunny bagBag310.0310.02.0FalseNoneNoneFalseNoneFalse620.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17253610850000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17253610850000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17253610850000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17253610850000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17253610850000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17253614440000NoneNoneELIGIBILITYAS PER KW3 TENDER DOCUMENTNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs.79.2 LAKHS(80% of estimated cost of tender)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete/PCC - 224.85 cum, TMT STEEL/STR. STEEL 9.76MT, etc) (80% of peak rate of construction)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs.198Lakhs)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. 29.70 Lakhs WITH INDENT NO MENTIONED (estimated cash flow for 3 months of peak construction period)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. 4.90 (not less than 50% of electrical works) n any one yearOthersRegistration certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneOwning the following key and critical equipment for this work (MENTIONED IN KW3 TENDER DOCUMENT)OthersEQUIPMENTS/MACHINERY REQUIREMENTS
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- EQUIPMENTS/MACHINERY REQUIREMENTS
NoneNoneNoneNoneList of existing commitments and ongoing worksOthersexisting commitments and ongoing works
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- existing commitments and ongoing works
NoneNoneNoneNoneList of works for which tenders already submittedOthersList of works of Tenders already submitted
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- List of works of Tenders already submitted
NoneNoneNoneNoneBanker Details for referenceOthersBanker Details
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Banker Details
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover Certificate Last Five YearsTrueTechnical Bid
Registration CertificateTrueTechnical Bid
similar nature of workdone BOQTrueTechnical Bid
Liquid asset certificateTrueTechnical Bid
GST Registration certificateTrueTechnical Bid
List Of Machines and EquipmentsTrueTechnical Bid
List of Tenders SubmittedTrueTechnical Bid
List of Ongoing Commitment WorksTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1725364202000
version0
createdDateNone
modifiedDateNone
blockNumberCMC OFFICE MEETING HALL , CMC DANDELI JN ROAD
streetNone
cityDANDELI
stateKarnataka
pin583125
tenderRecallDTONone