3928294 | 151526 | None | Item-01 | Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required to complete the work | Cum | 107.1 | 107.1 | 36.0 | False | None | None | False | None | False | 3855.6 | 0 |
3928295 | 151526 | None | Item-02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation The anite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 5.4 | False | None | None | False | None | False | 32114.88 | 0 |
3928296 | 151526 | None | Item-03 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) Beside Anganwadi | Cum | 6708.45 | 6708.45 | 10.8 | False | None | None | False | None | False | 72451.26 | 0 |
3928297 | 151526 | None | Item-04 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) In front of Anganwadi | Cum | 6708.45 | 6708.45 | 10.8 | False | None | None | False | None | False | 72451.26 | 0 |
3928298 | 151526 | None | Item-05 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6568.8 | 6568.8 | 4.05 | False | None | None | False | None | False | 26603.64 | 0 |
3928299 | 151526 | None | Item-06 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m | Cum | 279.3 | 279.3 | 7.65 | False | None | None | False | None | False | 2136.645 | 0 |
3928300 | 151526 | None | Item-07 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work In front of Anganwadi | Cum | 8376.9 | 8376.9 | 26.22 | False | None | None | False | None | False | 219642.318 | 0 |
3928301 | 151526 | None | Item-08 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. In front of Anganwadi | Cum | 404.25 | 404.25 | 285.0 | False | None | None | False | None | False | 115211.25 | 0 |
3928302 | 151526 | None | Item-09 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Cum | 55.65 | 55.65 | 344.62 | False | None | None | False | None | False | 19178.103 | 0 |
3928303 | 151526 | None | Item-10 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Cum | 93.45 | 93.45 | 285.0 | False | None | None | False | None | False | 26633.25 | 0 |
3928304 | 151526 | None | Item-11 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately). | Kg | 96.6 | 96.6 | 400.0 | False | None | None | False | None | False | 38640.0 | 0 |
3928305 | 151526 | None | Item-12 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 593.25 | 593.25 | 66.0 | False | None | None | False | None | False | 39154.5 | 0 |
3928306 | 151526 | None | Item-13 | Providing and fixing submercible pump of capacity 1 HP of approved make including cost of fixing wiring with motor starter (si no 2 (1/0.75) p no XLV | No | 14148.75 | 14148.75 | 1.0 | False | None | None | False | None | False | 14148.75 | 0 |
3928307 | 151526 | None | Item-14 | Providing and placing on terrace, Polyethylene water Storage tanks with manhole lid and suitable locking arrangements,making holes of suitable diameter for inlet, outlet and overflow pipes including cost of all materials, labour, transport charges, HOM of equipments and testing complete as per specifications. Specification No.KBS 13.22 (FOR 1000LTR CAPACITY) | Ltr | 9.45 | 9.45 | 1000.0 | False | None | None | False | None | False | 9450.0 | 0 |
3928308 | 151526 | None | Item-15 | Providing and fixing of mosquito net to the opening area, cost of work includes installation, erection, with standard material as per the specifications | Sqm | 1417.5 | 1417.5 | 4.0 | False | None | None | False | None | False | 5670.0 | 0 |
3928309 | 151526 | None | Item-16 | Plumbing work : Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests | Each | 4458.03 | 4458.03 | 1.0 | False | None | None | False | None | False | 4458.03 | 0 |
3928310 | 151526 | None | Item-17 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous China Flat back wash basin size 450x 300 mm with single 15mm C.P. brass pillar tap | Each | 1686.3 | 1686.3 | 1.0 | False | None | None | False | None | False | 1686.3 | 0 |
3928311 | 151526 | None | Item-18 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete. (external work). - 25mm nominal OD pipes with all leads & lifts, loading and unloading, hire charges of machinaries, all labour charges, and all other incidental charges, etc., complete as per detailed specifications and as directed by the Engineer-in-charge of the work. | Mtr | 187.95 | 187.95 | 25.0 | False | None | None | False | None | False | 4698.75 | 0 |
3928312 | 151526 | None | Item-19 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, including fixing of pipes with clamp at 1.00 mtr. spacing. This incluide jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete ( Internal work exposed on wall) 20mm dia | Mtr | 164.85 | 164.85 | 36.0 | False | None | None | False | None | False | 5934.6 | 0 |
3928313 | 151526 | None | Item-20 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, including fixing of pipes with clamp at 1.00 mtr. spacing. This incluide jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete ( Internal work exposed on wall) 15mm dia | Mtr | 136.5 | 136.5 | 22.0 | False | None | None | False | None | False | 3003.0 | 0 |
3928314 | 151526 | None | Item-21 | KSRB13-6.1-1 : Making and fixing in position brass stop cock of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification No.KBS 13.2.2 / 13.3 with all leads & lifts, loading and unloading, hire charges of machinaries, all labour charges, and all other incidental charges, etc., complete as per detailed specifications and as directed by the Engineer-in-charge of the work. | Nos | 199.5 | 199.5 | 4.0 | False | None | None | False | None | False | 798.0 | 0 |
3928315 | 151526 | None | Item-22 | KSRB 13-11.1: Providing and placing on terrace, polyethylene water storage tanks as per IS 12701 : 1996 with manhole lid and suitable locking aggangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of materials, labour, transport charges, HOM of equipments and testing complete as per specifications. (For 1000 litre capacity) Specification No. KBS 13.22 | Nos | 7169.4 | 7169.4 | 1.0 | False | None | None | False | None | False | 7169.4 | 0 |
3928316 | 151526 | None | Item-23 | Electrification works: Supplying heavy gauge PVC Conduit Pipe ….dia .......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25mm dia 2mm thick | Mtr | 80.0 | 80.0 | 55.0 | False | None | None | False | None | False | 4400.0 | 0 |
3928317 | 151526 | None | Item-24 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 2 X 1.5MM2 (Phase & Neutral) & 1 x 1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming of IS-694: and latest amendments ) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in wood / PVC round block completed for each outlet Short point upto 3Mtr from tapping point to out let via switch | Point | 276.0 | 276.0 | 4.0 | False | None | None | False | None | False | 1104.0 | 0 |
3928318 | 151526 | None | Item-25 | Point wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 2 X 1.5MM2 (Phase & Neutral) & 1 x 1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming of IS-694: and latest amendments ) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in wood / PVC round block completed for each outlet Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch | Point | 286.0 | 286.0 | 2.0 | False | None | None | False | None | False | 572.0 | 0 |
3928319 | 151526 | None | Item-26 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12mm thick wood, after due groove cutting, Finishing with necessary cement plastering complete. 8"x6"x3" (203x152x76mm) | Each | 75.0 | 75.0 | 3.0 | False | None | None | False | None | False | 225.0 | 0 |
3928320 | 151526 | None | Item-27 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. 1.5 sqmm | Mtr | 26.0 | 26.0 | 183.0 | False | None | None | False | None | False | 4758.0 | 0 |
3928321 | 151526 | None | Item-28 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A. 2.5 sqmm | Mtr | 40.0 | 40.0 | 150.0 | False | None | None | False | None | False | 6000.0 | 0 |
3928322 | 151526 | None | Item-29 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. Double Door 4 Wa SP & N | Each | 1368.0 | 1368.0 | 1.0 | False | None | None | False | None | False | 1368.0 | 0 |
3928323 | 151526 | None | Item-30 | Supplying of 2 feet - PVC Batten with integrated LED tube ...2 with high quality diffuser with Life of 25000 burning hours & 70 lumen maintenance with CRI 80. Power Input: 220-240V 5/600Hz & Power factor 0.9 along with CE approved drivers. 2 years Warranty against any manufacturing defect working under standard electrical condition LED hih fitting 1 4 20/22 W | Each | 740.0 | 740.0 | 12.0 | False | None | None | False | None | False | 8880.0 | 0 |
3928324 | 151526 | None | Item-31 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model | Each | 2085.0 | 2085.0 | 2.0 | False | None | None | False | None | False | 4170.0 | 0 |
3928325 | 151526 | None | Item-32 | Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. 6A Lamp Holder | Each | 63.0 | 63.0 | 12.0 | False | None | None | False | None | False | 756.0 | 0 |
3928326 | 151526 | None | Item-33 | Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. | Each | 119.0 | 119.0 | 12.0 | False | None | None | False | None | False | 1428.0 | 0 |
3928327 | 151526 | None | Item-34 | Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. | Each | 162.0 | 162.0 | 2.0 | False | None | None | False | None | False | 324.0 | 0 |
3928328 | 151526 | None | Item-35 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 6A 3/5 Way | Each | 143.0 | 143.0 | 5.0 | False | None | None | False | None | False | 715.0 | 0 |
3928329 | 151526 | None | Item-36 | Mural Painging on Walll: Mural Painting on wall with acrylic paint of approved brand and manufacture to give an even shade including preparing the surface after thoroughly cleaning the surface to removel all dirt, dust and foregin matter, cost of materials, labour etc. complete | Sqm | 5000.0 | 5000.0 | 13.88 | False | None | None | False | None | False | 69400.0 | 0 |