createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1725453745312
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd318000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose08-10-2024 16:00:00
tenderQueryClose01-10-2024 16:00:00
technicalBidOpen09-10-2024 16:05:00
publishedDate05-09-2024 12:54:42
publishedByPostBESCOM_GM_CIV_BNG
publishedByUserKPE16137 - T G RAMAKRISHNA
bidValidityPeriod90
noOfCalls1
preBidMeetingDate18-09-2024 15:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonT G Ramakrishna
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber8277892569
tenderSupplierListNone
tenderSchedule
createdTs1725453745344
version6
createdDateNone
modifiedDateNone
tenderNumberBESCOM/2024-25/BD/WORK_INDENT204
titleConstruction of Rural sub division office building at Yeluvahalli, Chikkaballapura
descriptionConstruction of Rural sub division office building at Yeluvahalli, Chikkaballapura
categoryWORKS
categoryTextWorks
ecv21185256.31
deptNameBangalore Electricity Supply Company Limited
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3834
locationNameBESCOM Corporate Office Civil Section Bengaluru
provisionalAmount25000000.0
groupOverheadTotal0.0
fileNumberBESCOM/GM/Civil/2024-25/52
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17254537450000NoneNoneBuildingsConstruction of Rural sub division office building at Yeluvahalli, Chikkaballapura21185256.31
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3921841151273NoneBOQ1Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. By Manual Means a) In area of light jungleha1155.661155.662.0473FalseNoneNoneFalseNoneFalse2365.9827180
3921842151273NoneBOQ2Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.Cum93.7393.7361.419FalseNoneNoneFalseNoneFalse5756.802870
3921843151273NoneBOQ3Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum249.26249.26155.0FalseNoneNoneFalseNoneFalse38635.30
3921844151273NoneBOQ4Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth exceeding 1.5m, but not exceeding 3 mCum266.77266.7743.0FalseNoneNoneFalseNoneFalse11471.110
3921845151273NoneBOQ5Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum273.98273.98145.0FalseNoneNoneFalseNoneFalse39727.10
3921846151273NoneBOQ6Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials, usage & all other appurtenaces required to complete the work.Cum488.22488.22172.0FalseNoneNoneFalseNoneFalse83973.840
3921847151273NoneBOQ7Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C / Lindane 20% E.C @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm121.54121.54174.0FalseNoneNoneFalseNoneFalse21147.960
3921848151273NoneBOQ8Providing and laying in position Cement Concrete for levelling course for all works in foundation The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregatesCum5833.925833.9229.0FalseNoneNoneFalseNoneFalse169183.680
3921849151273NoneBOQ9Providing and laying in position Cement Concrete for levelling course for all works in foundation The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates a) Stilt FloorCum6403.516403.516.0FalseNoneNoneFalseNoneFalse38421.060
3921850151273NoneBOQ10Providing and laying in position Cement Concrete for levelling course for all works in foundation The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates b) First FloorCum6467.556467.551.0FalseNoneNoneFalseNoneFalse6467.550
3921851151273NoneBOQ11Providing and laying in position Cement Concrete for levelling course for all works in foundation The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates c) Second FloorCum6531.586531.581.0FalseNoneNoneFalseNoneFalse6531.580
3921852151273NoneBOQ12Providing and laying in position Cement Concrete for levelling course for all works in foundation The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates d) Terrace FloorCum6595.626595.622.0FalseNoneNoneFalseNoneFalse13191.240
3921853151273NoneBOQ13Providing and laying Cement concrete pavement with 1:2:4 for commercial & residential building floors, hardpaths, footpaths using 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size, including finishing complete as per Engineer incharge.Cum6865.986865.9811.0FalseNoneNoneFalseNoneFalse75525.780
3921854151273NoneBOQ14Extra for making chequers of approved pattern on 1:2:4 cement concrete floors, steps, landing, pavements etc.Sqm56.6556.65110.0FalseNoneNoneFalseNoneFalse6231.50
3921855151273NoneBOQ15Providing and laying in position Reinforced cement concrete for all Foundation works The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6526.086526.0846.0FalseNoneNoneFalseNoneFalse300199.680
3921856151273NoneBOQ16Shuttering Work for Isolated FootingCum522.09522.0923.0FalseNoneNoneFalseNoneFalse12008.070
3921857151273NoneBOQ17Shuttering Work for Combined FootingCum195.78195.789.0FalseNoneNoneFalseNoneFalse1762.020
3921858151273NoneBOQ18Shuttering Work for Columns Upto Plinth BeamCum4568.264568.266.0FalseNoneNoneFalseNoneFalse27409.560
3921859151273NoneBOQ19Shuttering Work for Plinth BeamCum3263.043263.048.0FalseNoneNoneFalseNoneFalse26104.320
3921860151273NoneBOQ20Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts,cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6674.46674.427.5FalseNoneNoneFalseNoneFalse183546.00
3921861151273NoneBOQ21Shuttering Work for WallCum667.44667.4427.5FalseNoneNoneFalseNoneFalse18354.60
3921862151273NoneBOQ22Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7048.297048.2944.0FalseNoneNoneFalseNoneFalse310124.760
3921863151273NoneBOQ23Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates b) First FloorCum7118.777118.7745.0FalseNoneNoneFalseNoneFalse320344.650
3921864151273NoneBOQ24Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates c) Second FloorCum7189.267189.2645.0FalseNoneNoneFalseNoneFalse323516.70
3921865151273NoneBOQ25Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates d) Terrace FloorCum7259.747259.7411.0FalseNoneNoneFalseNoneFalse79857.140
3921866151273NoneBOQ26Shuttering Work for Columns - Stilt FloorCum4933.84933.88.0FalseNoneNoneFalseNoneFalse39470.40
3921867151273NoneBOQ27Shuttering Work for Columns - First FloorCum4983.144983.148.0FalseNoneNoneFalseNoneFalse39865.120
3921868151273NoneBOQ28Shuttering Work for Columns - Second FloorCum5032.485032.488.0FalseNoneNoneFalseNoneFalse40259.840
3921869151273NoneBOQ29Shuttering Work for Columns- Terrace FloorCum5081.825081.823.81FalseNoneNoneFalseNoneFalse19361.73420
3921870151273NoneBOQ30Shuttering Work for Roof Beam, Lintel Beam -Stilt FloorCum4228.974228.978.0FalseNoneNoneFalseNoneFalse33831.760
3921871151273NoneBOQ31Shuttering Work for Roof Beam, Lintel Beam - First FloorCum4271.264271.269.0FalseNoneNoneFalseNoneFalse38441.340
3921872151273NoneBOQ32Shuttering Work for Roof Beam, Lintel Beam - Second FloorCum4313.554313.559.0FalseNoneNoneFalseNoneFalse38821.950
3921873151273NoneBOQ33Shuttering Work for Roof Beam, Lintel Beam -Terrace FloorCum4355.844355.842.5FalseNoneNoneFalseNoneFalse10889.60
3921874151273NoneBOQ34Shuttering Work for Roof Slab - Stilt FloorCum3524.143524.1423.0FalseNoneNoneFalseNoneFalse81055.220
3921875151273NoneBOQ35Shuttering Work for Roof Slab - First FloorCum3559.393559.3922.0FalseNoneNoneFalseNoneFalse78306.580
3921876151273NoneBOQ36Shuttering Work for Roof Slab - Second FloorCum3594.633594.6322.0FalseNoneNoneFalseNoneFalse79081.860
3921877151273NoneBOQ37Shuttering Work for Roof Slab-Terrace FloorCum3629.873629.875.0FalseNoneNoneFalseNoneFalse18149.350
3921878151273NoneBOQ38Shuttering Work for Staircase Stilt FloorCum3524.153524.154.0FalseNoneNoneFalseNoneFalse14096.60
3921879151273NoneBOQ39Shuttering Work for Staircase - First FloorCum3559.393559.394.0FalseNoneNoneFalseNoneFalse14237.560
3921880151273NoneBOQ40Shuttering Work for Staircase - Second FloorCum3594.633594.634.0FalseNoneNoneFalseNoneFalse14378.520
3921881151273NoneBOQ41Shuttering Work for Chajja Stilt FloorCum3171.733171.730.5FalseNoneNoneFalseNoneFalse1585.8650
3921882151273NoneBOQ42Shuttering Work for Chajja - First FloorCum3203.453203.452.0FalseNoneNoneFalseNoneFalse6406.90
3921883151273NoneBOQ43Shuttering Work for Chajja - Second FloorCum3235.173235.172.0FalseNoneNoneFalseNoneFalse6470.340
3921884151273NoneBOQ44Shuttering Work for Chajja- Terrace FloorCum3266.883266.880.2FalseNoneNoneFalseNoneFalse653.3760
3921885151273NoneBOQ45Supplying, fitting and B32placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification separately) a) Stilt FloorTonne92140.7192140.7115.28FalseNoneNoneFalseNoneFalse1407910.04880
3921886151273NoneBOQ46Supplying, fitting and B32placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification separately) b) First FloorTonne93062.1293062.126.76FalseNoneNoneFalseNoneFalse629099.93120
3921887151273NoneBOQ47Supplying, fitting and B32placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification separately) c) Second FloorTonne93983.5293983.526.76FalseNoneNoneFalseNoneFalse635328.59520
3921888151273NoneBOQ48Supplying, fitting and B32placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification separately) d) Terrace FloorTonne94904.9394904.932.0468FalseNoneNoneFalseNoneFalse194251.4107240
3921889151273NoneBOQ49Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1349.31349.3144.0FalseNoneNoneFalseNoneFalse194299.20
3921890151273NoneBOQ50Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. b) First FloorSqm1362.791362.79218.0FalseNoneNoneFalseNoneFalse297088.220
3921891151273NoneBOQ51Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. c) Second FloorSqm1376.291376.29189.0FalseNoneNoneFalseNoneFalse260118.810
3921892151273NoneBOQ52Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. d) Terrace FloorSqm1389.781389.78109.0FalseNoneNoneFalseNoneFalse151486.020
3921893151273NoneBOQ53Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specificationsSqm1137.121137.128.0FalseNoneNoneFalseNoneFalse9096.960
3921894151273NoneBOQ54Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications b) First FloorSqm1148.491148.4944.0FalseNoneNoneFalseNoneFalse50533.560
3921895151273NoneBOQ55Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications c) Second FloorSqm1159.861159.8654.0FalseNoneNoneFalseNoneFalse62632.440
3921896151273NoneBOQ56Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications d) Terrace FloorSqm1171.231171.232.0FalseNoneNoneFalseNoneFalse2342.460
3921897151273NoneBOQ57Providing and fixing M.S grills of required pattern in frames of windows etc with M.S flats, square or round bars etc including priming coat with approved steel primer all complete Fixed to openings / wooden frames with rawl plugs screws etc.Kg188.49188.4994.0FalseNoneNoneFalseNoneFalse17718.060
3921898151273NoneBOQ58Providing and fixing M.S grills of required pattern in frames of windows etc with M.S flats, square or round bars etc including priming coat with approved steel primer all complete Fixed to openings / wooden frames with rawl plugs screws etc. b) First FloorKg190.37190.37422.0FalseNoneNoneFalseNoneFalse80336.140
3921899151273NoneBOQ59Providing and fixing M.S grills of required pattern in frames of windows etc with M.S flats, square or round bars etc including priming coat with approved steel primer all complete Fixed to openings / wooden frames with rawl plugs screws etc. c) Second FloorKg192.26192.26420.0FalseNoneNoneFalseNoneFalse80749.20
3921900151273NoneBOQ60Providing and fixing M.S grills of required pattern in frames of windows etc with M.S flats, square or round bars etc including priming coat with approved steel primer all complete Fixed to openings / wooden frames with rawl plugs screws etc. d) Terrace FloorKg194.14194.1443.0FalseNoneNoneFalseNoneFalse8348.020
3921901151273NoneBOQ61Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock Wall thickness of frame & sash shall be of 2mm-2.5mm Maximum possible size 2419mm x 2200mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm6936.026936.023.0FalseNoneNoneFalseNoneFalse20808.060
3921902151273NoneBOQ62Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock Wall thickness of frame & sash shall be of 2mm-2.5mm Maximum possible size 2419mm x 2200mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) b) First FloorSqm7005.387005.3819.0FalseNoneNoneFalseNoneFalse133102.220
3921903151273NoneBOQ63Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock Wall thickness of frame & sash shall be of 2mm-2.5mm Maximum possible size 2419mm x 2200mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) c) Second FloorSqm7074.747074.7419.0FalseNoneNoneFalseNoneFalse134420.060
3921904151273NoneBOQ64Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock Wall thickness of frame & sash shall be of 2mm-2.5mm Maximum possible size 2419mm x 2200mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) d) Terrace FloorSqm7144.17144.13.0FalseNoneNoneFalseNoneFalse21432.30
3921905151273NoneBOQ65Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) b) First FloorSqm5949.485949.481.5FalseNoneNoneFalseNoneFalse8924.220
3921906151273NoneBOQ66Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) c) Second FloorSqm6008.386008.381.5FalseNoneNoneFalseNoneFalse9012.570
3921907151273NoneBOQ67Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg581.95581.95115.0FalseNoneNoneFalseNoneFalse66924.250
3921908151273NoneBOQ68Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. b) First FloorKg587.77587.77115.0FalseNoneNoneFalseNoneFalse67593.550
3921909151273NoneBOQ69Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc. of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. c) Second FloorKg593.59593.59115.0FalseNoneNoneFalseNoneFalse68262.850
3921910151273NoneBOQ70Providing and fixing hand rail of approved size by welding etc to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer M.S tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. d) Terrace FloorKg146.4146.4295.0FalseNoneNoneFalseNoneFalse43188.00
3921911151273NoneBOQ71FULLY GLAZED PARTITION WITH TOUGHENED GLASS & ALUMINIUM CHANNELS Providing and fixing full height glass partition with 12mm thick clear toughened glass as per design fitted over aluminium channels bottom and at top as detailed The partition frame work above false ceiling to be fitted firmly to the true ceiling with necessary anchor fasteners All the edges of glass shall have pencil nosing and machine polished The joints in glass shall be filled with colourless silicone sealant as per manufacturer specifications. including necessary scaffolding support etc Make: Saint Gobain Series - SGG ET 725 SGU/ EquivalentSqm6850.06850.055.0FalseNoneNoneFalseNoneFalse376750.00
3921912151273NoneBOQ72Providing and fixing Single shutter glass door of 12mm thick frosted toughened glass of approved make The door is fixed by using any approved make hardware fitting like patch fitting, pivot floor machine, locking arrangements and suitable SS door rails with floral glass etching for 113 portion of door area etc complete The rate includes cost of all materials, labour, hire of tools & machineries, as per specification.Sqm9669.649669.6412.0FalseNoneNoneFalseNoneFalse116035.680
3921913151273NoneBOQ73Providing, fabricating and fixing of stick type structural glazing using Alluminium Extrusions of 63.5 mm x 58.00 mmx 2.25 mm of 1.73 kgs/ mtr for vertical and Horizontal members and 63.5 mm x 38.1 x 1.33 mm of 0.759 kg/Mtr, as outer frame with Electro Anodized Paint coated block finishing, using 6mm thick imported glass reflective hard coatedocean blue raw glass with all necessary accesories like ultra glass Silicon sealant of Space tape, Masking tape, Galvanized Anchaor bolt, machine screws, 6mm thick M.S angle 50mm x 150mm x 6mm M.S Galvanized L Brackets, structural sealent setting clocks, fasteners, wall connection etc. complete.Sqm6852.596852.5912.0FalseNoneNoneFalseNoneFalse82231.080
3921914151273NoneBOQ74Providing, fabricating and fixing of stick type structural glazing using Alluminium Extrusions of 63.5 mm x 58.00 mmx 2.25 mm of 1.73 kgs/ mtr for vertical and Horizontal members and 63.5 mm x 38.1 x 1.33 mm of 0.759 kg/Mtr, as outer frame with Electro Anodized Paint coated block finishing, using 6mm thick imported glass reflective hard coatedocean blue raw glass with all necessary accesories like ultra glass Silicon sealant of Space tape, Masking tape, Galvanized Anchaor bolt, machine screws, 6mm thick M.S angle 50mm x 150mm x 6mm M.S Galvanized L Brackets, structural sealent setting clocks, fasteners, wall connection etc. complete. b) First FloorSqm6858.776858.7734.0FalseNoneNoneFalseNoneFalse233198.180
3921915151273NoneBOQ75Providing, fabricating and fixing of stick type structural glazing using Alluminium Extrusions of 63.5 mm x 58.00 mmx 2.25 mm of 1.73 kgs/ mtr for vertical and Horizontal members and 63.5 mm x 38.1 x 1.33 mm of 0.759 kg/Mtr, as outer frame with Electro Anodized Paint coated block finishing, using 6mm thick imported glass reflective hard coatedocean blue raw glass with all necessary accesories like ultra glass Silicon sealant of Space tape, Masking tape, Galvanized Anchaor bolt, machine screws, 6mm thick M.S angle 50mm x 150mm x 6mm M.S Galvanized L Brackets, structural sealent setting clocks, fasteners, wall connection etc. complete. c) Second FloorSqm6864.956864.9534.0FalseNoneNoneFalseNoneFalse233408.30
3921916151273NoneBOQ76Providing and Fixing Baguette Terracotta tile with aluminium support bars and frame work complete as per instructions of engineer in chargeSqm3500.03500.013.0FalseNoneNoneFalseNoneFalse45500.00
3921917151273NoneBOQ77Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications..Cum142216.22142216.220.4FalseNoneNoneFalseNoneFalse56886.4880
3921918151273NoneBOQ78Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.. b) First FloorCum143638.38143638.380.3FalseNoneNoneFalseNoneFalse43091.5140
3921919151273NoneBOQ79Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.. c) Second FloorCum145060.54145060.540.2FalseNoneNoneFalseNoneFalse29012.1080
3921920151273NoneBOQ80Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.. d) Terrace FloorCum146482.71146482.710.1FalseNoneNoneFalseNoneFalse14648.2710
3921921151273NoneBOQ81Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications ( excluding cost of fixtures )Sqm7103.917103.918.0FalseNoneNoneFalseNoneFalse56831.280
3921922151273NoneBOQ82Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications ( excluding cost of fixtures ) b) First floorSqm7174.957174.953.5FalseNoneNoneFalseNoneFalse25112.3250
3921923151273NoneBOQ83Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications ( excluding cost of fixtures ) c) Second FloorSqm7245.997245.993.5FalseNoneNoneFalseNoneFalse25360.9650
3921924151273NoneBOQ84Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991 from manufacturer complete as per spcification. -do- 35 mm thick both side teakSqm4667.964667.962.5FalseNoneNoneFalseNoneFalse11669.90
3921925151273NoneBOQ85Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991 from manufacturer complete as per spcification. -do- 35 mm thick both side teak b) First FloorSqm4714.644714.646.0FalseNoneNoneFalseNoneFalse28287.840
3921926151273NoneBOQ86Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991 from manufacturer complete as per spcification. -do- 35 mm thick both side teak c) Second FloorSqm4761.324761.3238.5FalseNoneNoneFalseNoneFalse183310.820
3921927151273NoneBOQ87Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991 from manufacturer complete as per spcification. -do- 35 mm thick both side teak d) Terrace FloorSqm4807.994807.992.0FalseNoneNoneFalseNoneFalse9615.980
3921928151273NoneBOQ88Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge (Fixtures shall be paid for separately) Size 62 x 100mm b) First FloorRmtr730.29730.2915.0FalseNoneNoneFalseNoneFalse10954.350
3921929151273NoneBOQ89Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge (Fixtures shall be paid for separately) Size 62 x 100mm c) Second FloorRmtr737.52737.5210.0FalseNoneNoneFalseNoneFalse7375.20
3921930151273NoneBOQ90Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thickness b) First FloorSqm3625.453625.455.5FalseNoneNoneFalseNoneFalse19939.9750
3921931151273NoneBOQ91Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood Polymer Composite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thickness c) Second FloorSqm3661.343661.343.5FalseNoneNoneFalseNoneFalse12814.690
3921932151273NoneBOQ92Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m including cost of materials, labour charges, complete as per specifications.Nos1046.481046.483.0FalseNoneNoneFalseNoneFalse3139.440
3921933151273NoneBOQ93Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m including cost of materials, labour charges, complete as per specifications. b) First FloorNos1056.941056.944.0FalseNoneNoneFalseNoneFalse4227.760
3921934151273NoneBOQ94Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m including cost of materials, labour charges, complete as per specifications. c) Second FloorNos1067.411067.413.0FalseNoneNoneFalseNoneFalse3202.230
3921935151273NoneBOQ95Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m including cost of materials, labour charges, complete as per specifications. d) Terrace FloorNos1077.871077.871.0FalseNoneNoneFalseNoneFalse1077.870
3921936151273NoneBOQ96Providing supply and fixing SS 304 Aldrop - 200mm x 16mm for door shutters including SS screws cost of materials, labour etc. complete as per specifications of vendor and as per architects details Make: GODREJ / 8539 Stilt Floor ---- ETC..AS PER SPECIFICATION & DIRECTION OF ENGINEER IN CHARGENos1919.01919.017.0FalseNoneNoneFalseNoneFalse32623.00
3921937151273NoneBOQ97Providing supply and fixing Cylindrical Lock-SS-Key less with 5 years warranty suitable for Flush door shutters including cost of materials, labour etc. complete as per specifications of vendor and as per architects details Make: GODREJ / 9843 Stilt Floor ---- ETC..AS PER SPECIFICATION & DIRECTION OF ENGINEER IN CHARGENos2000.02000.011.0FalseNoneNoneFalseNoneFalse22000.00
3921938151273NoneBOQ98Providing and fixing bright finished brass handles with screws etc complete: Brass handles 125 mm with plate 175x32 mmNos256.47256.478.0FalseNoneNoneFalseNoneFalse2051.760
3921939151273NoneBOQ99Providing and fixing bright finished brass handles with screws etc complete: Brass handles 125 mm with plate 175x32 mm b) First FloorNos259.03259.0316.0FalseNoneNoneFalseNoneFalse4144.480
3921940151273NoneBOQ100Providing and fixing bright finished brass handles with screws etc complete: Brass handles 125 mm with plate 175x32 mm c) Second FloorNos261.6261.610.0FalseNoneNoneFalseNoneFalse2616.00
3921941151273NoneBOQ101Providing and fixing bright finished brass handles with screws etc complete: Brass handles 125 mm with plate 175x32 mm d) Terrace FloorNos264.16264.162.0FalseNoneNoneFalseNoneFalse528.320
3921942151273NoneBOQ102Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc to suit shutter thickness completeNos243.08243.084.0FalseNoneNoneFalseNoneFalse972.320
3921943151273NoneBOQ103Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc to suit shutter thickness complete b) First FloorNos245.51245.515.0FalseNoneNoneFalseNoneFalse1227.550
3921944151273NoneBOQ104Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc to suit shutter thickness complete c) Second FloorNos247.94247.944.0FalseNoneNoneFalseNoneFalse991.760
3921945151273NoneBOQ105Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc to suit shutter thickness complete d) Terrace FloorNos250.37250.371.0FalseNoneNoneFalseNoneFalse250.370
3921946151273NoneBOQ106Providing and fixing bright finished brass butt hinges with necessary screws etc complete : 125x85x5.5 mm (heavy type)Nos283.25283.2512.0FalseNoneNoneFalseNoneFalse3399.00
3921947151273NoneBOQ107Providing and fixing bright finished brass butt hinges with necessary screws etc complete : 125x85x5.5 mm (heavy type) b) First FloorNos286.08286.0824.0FalseNoneNoneFalseNoneFalse6865.920
3921948151273NoneBOQ108Providing and fixing bright finished brass butt hinges with necessary screws etc complete : 125x85x5.5 mm (heavy type) c) Second FloorNos288.91288.9118.0FalseNoneNoneFalseNoneFalse5200.380
3921949151273NoneBOQ109Providing and fixing bright finished brass butt hinges with necessary screws etc complete : 125x85x5.5 mm (heavy type) d) Terrace FloorNos291.7291.73.0FalseNoneNoneFalseNoneFalse875.10
3921950151273NoneBOQ110Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc complete : 250x10mmNos448.05448.0510.0FalseNoneNoneFalseNoneFalse4480.50
3921951151273NoneBOQ111Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc complete : 250x10mm b) First FloorNos452.53452.5313.0FalseNoneNoneFalseNoneFalse5882.890
3921952151273NoneBOQ112Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc complete : 250x10mm c) Second FloorNos457.01457.019.0FalseNoneNoneFalseNoneFalse4113.090
3921953151273NoneBOQ113Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc complete : 250x10mm d) Terrace FloorNos461.49461.493.0FalseNoneNoneFalseNoneFalse1384.470
3921954151273NoneBOQ114Providing supply and fixing MS Holdfast of size 260mm x 25mm x 5mm thk for fixing door frame to walls including cost of materials, cutting masonry pockets for receiving MS Holdfast, one coat of shop primer , concrete filling of pockets, disposal of debris,keeping the area clean,curing, labour etc. complete as per specifications of vendor and as per architects details Stilt Floor ---- ETC..AS PER SPECIFICATION & DIRECTION OF ENGINEER IN CHARGENos45.045.066.0FalseNoneNoneFalseNoneFalse2970.00
3921955151273NoneBOQ115Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412 The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. d) Terrace FloorSqm866.76866.76193.5FalseNoneNoneFalseNoneFalse167718.060
3921956151273NoneBOQ116Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 L/m2, and spreading 60 gsm geotextile between two top coats completely as per specification The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. b) First FloorSqm766.7766.716.0FalseNoneNoneFalseNoneFalse12267.20
3921957151273NoneBOQ117Providing and Applying PU based Elastomeric Liquid Applied PU Waterproofing Membrane single component, cold applied, water based acrylic PU dispersion with highly elastic and UV resistant water proofing treatment to the Existing Roof surface/Chajjas/Sunken portion of WC:Bathroom applied @ 1.2L/per m2,having tensile strength greater than 1.5N/mm2, elongation greater than 300% with solid content not less than 60% in 2 coats including surface preparation, priming the surface with water based acrylic primer @0.1 L/m2, and spreading 60 gsm geotextile between two top coats completely as per specification The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. c) Second floorSqm774.29774.2920.0FalseNoneNoneFalseNoneFalse15485.80
3921958151273NoneBOQ118Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs,laid to slope compacting, including cost of materials, labour, curing complete as per specifications b) First FloorCum2098.292098.293.0FalseNoneNoneFalseNoneFalse6294.870
3921959151273NoneBOQ119Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs,laid to slope compacting, including cost of materials, labour, curing complete as per specifications c) Second floorCum2119.062119.063.5FalseNoneNoneFalseNoneFalse7416.710
3921960151273NoneBOQ120Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates b) First FloorCum6897.196897.190.5FalseNoneNoneFalseNoneFalse3448.5950
3921961151273NoneBOQ121Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates c) Second floorCum6965.486965.480.6FalseNoneNoneFalseNoneFalse4179.2880
3921962151273NoneBOQ122Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates d) Terrace FloorCum7033.777033.7714.0FalseNoneNoneFalseNoneFalse98472.780
3921963151273NoneBOQ123Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent.Sqm2539.982539.9838.1FalseNoneNoneFalseNoneFalse96773.2380
3921964151273NoneBOQ124Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent. b) First FloorSqm2565.382565.3825.0FalseNoneNoneFalseNoneFalse64134.50
3921965151273NoneBOQ125Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite stone slab Black, Cat Eye, River Pink or equivalent. c) Second floorSqm2590.782590.7825.0FalseNoneNoneFalseNoneFalse64769.50
3921966151273NoneBOQ126Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.Sqm2937.562937.566.5FalseNoneNoneFalseNoneFalse19094.140
3921967151273NoneBOQ127Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc complete as per design approved by Engineer-in-charge.Rmtr337.84337.8435.0FalseNoneNoneFalseNoneFalse11824.40
3921968151273NoneBOQ128Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc complete as per design approved by Engineer-in-charge. b) First floorRmtr341.22341.2235.0FalseNoneNoneFalseNoneFalse11942.70
3921969151273NoneBOQ129Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc complete as per design approved by Engineer-in-charge. c) Second floorRmtr344.6344.635.0FalseNoneNoneFalseNoneFalse12061.00
3921970151273NoneBOQ130Providing and laying Polished Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).. Size of Tile 600x1200 mmSqm2049.72049.718.0FalseNoneNoneFalseNoneFalse36894.60
3921971151273NoneBOQ131Providing and laying Polished Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).. Size of Tile 600x1200 mm b) First FloorSqm2070.22070.2128.0FalseNoneNoneFalseNoneFalse264985.60
3921972151273NoneBOQ132Providing and laying Polished Glazed Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).. Size of Tile 600x1200 mm c) Second floorSqm2090.692090.69127.0FalseNoneNoneFalseNoneFalse265517.630
3921973151273NoneBOQ133Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge.Sqm215.27215.2718.0FalseNoneNoneFalseNoneFalse3874.860
3921974151273NoneBOQ134Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. b) First FloorSqm217.42217.42128.0FalseNoneNoneFalseNoneFalse27829.760
3921975151273NoneBOQ135Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix of 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg), including filling / grouting and finishing complete as per direction of Engineer-in-charge. c) Second floorSqm219.58219.58127.0FalseNoneNoneFalseNoneFalse27886.660
3921976151273NoneBOQ136Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc. complete. b) First FloorSqm924.83924.8310.0FalseNoneNoneFalseNoneFalse9248.30
3921977151273NoneBOQ137Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc. complete. c) Second floorSqm933.98933.9812.0FalseNoneNoneFalseNoneFalse11207.760
3921978151273NoneBOQ138Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. b) First FloorSqm1507.391507.3942.0FalseNoneNoneFalseNoneFalse63310.380
3921979151273NoneBOQ139Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. c) Second floorSqm1522.321522.3249.0FalseNoneNoneFalseNoneFalse74593.680
3921980151273NoneBOQ140Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) greater than 78, solar reflection greater than 0.70 and initial emittance greater than 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner as per direction of incharge. d) Terrace FloorSqm1490.561490.56178.0FalseNoneNoneFalseNoneFalse265319.680
3921981151273NoneBOQ141Providing and fixing of clay tiles for cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface and the surface is painted with red apex paint and black apex paint into the groves The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc. complete as per specification.Sqm1959.061959.0619.5FalseNoneNoneFalseNoneFalse38201.670
3921982151273NoneBOQ142Providing and fixing of clay tiles for cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface and the surface is painted with red apex paint and black apex paint into the groves The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc. complete as per specification. b) First floorSqm1978.651978.6525.5FalseNoneNoneFalseNoneFalse50455.5750
3921983151273NoneBOQ143Providing and fixing of clay tiles for cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface and the surface is painted with red apex paint and black apex paint into the groves The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc. complete as per specification. c) Second floorSqm1998.241998.2437.0FalseNoneNoneFalseNoneFalse73934.880
3921984151273NoneBOQ144Providing and fixing of clay tiles for cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface and the surface is painted with red apex paint and black apex paint into the groves The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc. complete as per specification. d) Terrace FloorSqm2017.832017.8315.5FalseNoneNoneFalseNoneFalse31276.3650
3921985151273NoneBOQ145Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal wall plasteringSqm287.37287.37245.0FalseNoneNoneFalseNoneFalse70405.650
3921986151273NoneBOQ146Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal wall plastering b) First FloorSqm290.24290.24430.0FalseNoneNoneFalseNoneFalse124803.20
3921987151273NoneBOQ147Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal wall plastering c) Second floorSqm293.12293.12421.0FalseNoneNoneFalseNoneFalse123403.520
3921988151273NoneBOQ148Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal wall plastering d) Terrace FloorSqm295.99295.9970.0FalseNoneNoneFalseNoneFalse20719.30
3921989151273NoneBOQ149Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Rough plastering b) First FloorSqm306.89306.8942.0FalseNoneNoneFalseNoneFalse12889.380
3921990151273NoneBOQ150Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Rough plastering c) Second floorSqm309.93309.9349.0FalseNoneNoneFalseNoneFalse15186.570
3921991151273NoneBOQ151Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External PlasteringSqm396.55396.55187.0FalseNoneNoneFalseNoneFalse74154.850
3921992151273NoneBOQ152Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Plastering b) First FloorSqm400.52400.52212.5FalseNoneNoneFalseNoneFalse85110.50
3921993151273NoneBOQ153Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Plastering c) Second floorSqm404.48404.48215.5FalseNoneNoneFalseNoneFalse87165.440
3921994151273NoneBOQ154Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Plastering d) Terrace FloorSqm408.45408.45179.0FalseNoneNoneFalseNoneFalse73112.550
3921995151273NoneBOQ155Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling PlasteringSqm332.69332.69171.0FalseNoneNoneFalseNoneFalse56889.990
3921996151273NoneBOQ156Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling Plastering b) First FloorSqm336.02336.02165.0FalseNoneNoneFalseNoneFalse55443.30
3921997151273NoneBOQ157Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling Plastering c) Second floorSqm339.34339.34165.0FalseNoneNoneFalseNoneFalse55991.10
3921998151273NoneBOQ158Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling Plastering d) Terrace FloorSqm342.67342.6729.0FalseNoneNoneFalseNoneFalse9937.430
3921999151273NoneBOQ159Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications ( length of mesh only be measured for payment Plaster mesh 100mm wideRmtr45.3245.32228.5FalseNoneNoneFalseNoneFalse10355.620
3922000151273NoneBOQ160Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications ( length of mesh only be measured for payment Plaster mesh 100mm wide b) First FloorRmtr45.7745.77448.5FalseNoneNoneFalseNoneFalse20527.8450
3922001151273NoneBOQ161Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications ( length of mesh only be measured for payment Plaster mesh 100mm wide c) Second floorRmtr46.2346.23412.0FalseNoneNoneFalseNoneFalse19046.760
3922002151273NoneBOQ162Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications ( length of mesh only be measured for payment Plaster mesh 100mm wide d) Terrace FloorRmtr46.6846.68166.0FalseNoneNoneFalseNoneFalse7748.880
3922003151273NoneBOQ163Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (a) Stilt FloorSqm103.0103.0416.0FalseNoneNoneFalseNoneFalse42848.00
3922004151273NoneBOQ164Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. b) First FloorSqm104.03104.03595.0FalseNoneNoneFalseNoneFalse61897.850
3922005151273NoneBOQ165Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. c) Second floorSqm105.06105.06595.0FalseNoneNoneFalseNoneFalse62510.70
3922006151273NoneBOQ166Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. d) Terrace FloorSqm106.09106.0999.0FalseNoneNoneFalseNoneFalse10502.910
3922007151273NoneBOQ167Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour Two coats as per specifications and as per directions of Engineer in charge. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge.Sqm167.89167.89416.0FalseNoneNoneFalseNoneFalse69842.240
3922008151273NoneBOQ168Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour Two coats as per specifications and as per directions of Engineer in charge. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. b) First FloorSqm169.57169.57595.0FalseNoneNoneFalseNoneFalse100894.150
3922009151273NoneBOQ169Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour Two coats as per specifications and as per directions of Engineer in charge. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. c) Second floorSqm171.25171.25595.0FalseNoneNoneFalseNoneFalse101893.750
3922010151273NoneBOQ170Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour Two coats as per specifications and as per directions of Engineer in charge. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre as per specifications and as per directions of Engineer in charge. d) Terrace FloorSqm172.93172.9399.0FalseNoneNoneFalseNoneFalse17120.070
3922011151273NoneBOQ171Providing textured paint of approved quality, colour and shade to wall surface after cleaning and rubbing the wall surface with wire brush of medium size emery stone to remove all the loosely adhering particles, the surface is then cleaned with water and ensured that it is in line and level The textured material is then mixed with 40-50% of clean water until a homogeneous thick slurry is formed, the slurry is left for 5-10 min, to react completely with ingredients The textured finish prepared as above is then applied to the wall surface with suitable roller/spray gun/putty/ blade/ trowel to get the desired finish The finished surface shall be applied with two coats of exterior apex paint of approved shade The rate includes providing and removing scaffolding, all lead and lift and all other incidental charges etc. complete as per directions of the Engineer-in-charge of the work.Sqm452.17452.1729.0FalseNoneNoneFalseNoneFalse13112.930
3922012151273NoneBOQ172Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m² Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm160.68160.68138.5FalseNoneNoneFalseNoneFalse22254.180
3922013151273NoneBOQ173Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m² Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. b) First FloorSqm173.04173.04187.0FalseNoneNoneFalseNoneFalse32358.480
3922014151273NoneBOQ174Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m² Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. c) Second floorSqm185.4185.4150.0FalseNoneNoneFalseNoneFalse27810.00
3922015151273NoneBOQ175Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m² Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. d) Terrace FloorSqm197.76197.76163.5FalseNoneNoneFalseNoneFalse32333.760
3922016151273NoneBOQ176Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. b) First FloorSqm173.73173.7321.0FalseNoneNoneFalseNoneFalse3648.330
3922017151273NoneBOQ177Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. c) Second floorSqm175.45175.4521.0FalseNoneNoneFalseNoneFalse3684.450
3922018151273NoneBOQ178Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. d) Terrace FloorSqm177.17177.1714.0FalseNoneNoneFalseNoneFalse2480.380
3922019151273NoneBOQ179Painting wood work with Deluxe Multi Surface Paint of required shade Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm142.14142.1425.0FalseNoneNoneFalseNoneFalse3553.50
3922020151273NoneBOQ180Painting wood work with Deluxe Multi Surface Paint of required shade Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. b) First FloorSqm143.56143.5622.0FalseNoneNoneFalseNoneFalse3158.320
3922021151273NoneBOQ181Painting wood work with Deluxe Multi Surface Paint of required shade Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. c) Second floorSqm144.98144.9817.0FalseNoneNoneFalseNoneFalse2464.660
3922022151273NoneBOQ182Painting wood work with Deluxe Multi Surface Paint of required shade Two coat applied @ 0.90L/10 m² over an under coat of primer applied @0.75 L/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. d) Terrace FloorSqm146.4146.45.0FalseNoneNoneFalseNoneFalse732.00
3922023151273NoneBOQ183Providing and fixing Gypsum false ceiling as per India Gypsum specification for ceiling with drops as per drawing including of providing and fixing G.I Frame work as per specification of India gypsum at a distance of 2'0" clc both ways complete with 12.5mm board (IS-2095-1982) had all necessary perimeter channels etc No extra payment will be made for the cutting of light points, stain glass, cove lighting etc The measurement will be taken in one level , rate should include the drops also no extra amount will be paid for the drops The joints to be properly mended with paper tapes and gypsum compound all complete The rate should include the full completion of the ceiling At the time of handing over the site all necessary repairing work to be considered if required The work to be completed as per specification ,design and approval of the Architect.Sqm1200.01200.011.0FalseNoneNoneFalseNoneFalse13200.00
3922024151273NoneBOQ184Providing & Fixing of Mineral Fibre Acoustical Suspended Ceiling System in module size of 600 x 600 x 20mm with Exposed Grid for Hospitals, Shopping malls, Commercial establishments and office complexes The tiles should have Humidity Resistance (RH) of 99%, NRC 0.7, Light Reflectance 85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 I Class 1 (BS 476 pt- 6 & 7)with sand texture finish andsuitable for Green Building application with Recycled content of 47% The tile shall be laid on 24 mm wide T- section flanges colour white having rotary stitching on all T sections i.e the Main Runner, 1200 mm & 600 mm Cross Tees with a web height of 38mm and a load carrying capacity of 15 kg/m2 &pull out strength of minimum 100 kg The T Sections should have a Galvanizing of 90 g/m2 and need to be installed with Suspension systemSqm2770.72770.732.0FalseNoneNoneFalseNoneFalse88662.40
3922025151273NoneBOQ185Non Sharing workstation Size : 1200 mmW x 600mm D x 1200 mm ht (Non Sharing-Edgebinding table top): single unitNos14000.014000.016.0FalseNoneNoneFalseNoneFalse224000.00
3922026151273NoneBOQ186FREE STANDING TABLE FOR CABIN - WITHOUT FRAMES Providing and fixing Free Standing Table for Cabin- without frames consisting of 25 mm thick PLPB table top , 25 mm thick PLPB with edge bomded End table,18 mm thick PLPB with edge bonded Modesty, Wire manager -ABS plastic grommet one number per table Hardware-Minifix assembly and screw leg. as per specifications, drawings and as directed by Engineer in charge Main Table : 1200 mmW x 540mm D x 750 mm ht (Main table with post formed table top)Nos25000.025000.05.0FalseNoneNoneFalseNoneFalse125000.00
3922027151273NoneBOQ187Providing and fixing L-shape table made with prelaminated particle board Table top made with 25mm and understructure made with 18mm board.storage box made with 18mm prelaminated board This is including Credenza of Two drawer and double door box comes in this storage box. Size: 1500mm x 1500mm x 600mm Make: Featherlite / EquivalentNos15000.015000.01.0FalseNoneNoneFalseNoneFalse15000.00
3922028151273NoneBOQ188Providing and fixing conference table consisting of 19 mm double thick Ply table top edge bounded with 6 mm thick CORIAN top finish at top area and at sides with 45mm depth corian finish, 19 mm double thick Ply with edge bonded End table with 2 mm Acrylic laminate finish on Exposed area of table at both sides, Vertical supports underneath the top table (for Inside compartments) with 19 mm thick ply and 0.8mm thick laminate Finish Each individual provided with mic arrangements (Audio Visual works) on table top with hidden wiring Hardware- Minifix assembly and screw leg. as per specifications, drawings and as directed by instructions Conference Table total length 11.50 m Main chair table dimensions: 2.1m X 0.9m X 0.75m Sub chair Table dimensions- 2 sides- 4.7m X 0.75m X 0.75m Seating capacity - 1 nos Main chairs and 14 Nos of Sub ChairsNos200000.0200000.01.0FalseNoneNoneFalseNoneFalse200000.00
3922029151273NoneBOQ189Supplying Black Medium Back Mesh chair of size 585mm(L)x585mm(W)x1040mm(H) with cushion seat and mesh back with cushion arms and nylon base with Pnuematic height adjustable system with wheel rollers complete as per specification Make: Featherlite/EquivalentNos8000.08000.038.0FalseNoneNoneFalseNoneFalse304000.00
3922030151273NoneBOQ190Supplying Liberate High Back Mesh chair of size 660mm(L)x660mm(W)x1250mm(H) with cushion seat and mesh back with cushion arms and chrome plated metal base with Pnuematic height adjustable system with wheel rollers complete as per specification Make: Featherlite/EquivalentNos15000.015000.04.0FalseNoneNoneFalseNoneFalse60000.00
3922031151273NoneBOQ191Supplying and placing of 3 Seater sofa of Leatherite finish of size, Length-1200mm, Width-710mm, Height-780 mm, and seating height 410mm, of approved make & color etc. complete as per specifications. Make: Approved makeNos40000.040000.02.0FalseNoneNoneFalseNoneFalse80000.00
3922032151273NoneBOQ192Supplying and placing of 3 Seater sofa of Leatherite finish of size, Length-1800mm, Width-710mm, Height-780 mm, and seating height 410mm, of approved make & color etc. complete as per specifications. Make: Approved makeNos55000.055000.01.0FalseNoneNoneFalseNoneFalse55000.00
3922033151273NoneBOQ193Providing and fixing storage unit made out of 19mm thick Approved commercial ply for shutters, sides, bottom, Compartments and Drawers finished with Acrylic laminate (Approved make and shade) of 2 mm thick at external surface and 0.8 mm thick at internal surface of storage unit 6mm thick Commercial ply back for Wall side Shutters and Drawers provided with approved aluminium channels, SS handles, Hinges, Lock arrangements, etc. complete the rate includes cost of all materials, labour charges, complete as per specificationSqm20000.020000.07.0FalseNoneNoneFalseNoneFalse140000.00
3922034151273NoneBOQ1945 BAY MOBILE RACK COMPACTOR Total no.of Racks of size 1980mm H X 1000mm W X 380mm D with 5 compartment-80 Nos, Capacity of Flat Files considering 25mm thickness-16000 files (OR) Capacity of Box Files considering 90mm thickness-4480 files, Epoxy Powder Coated Finish, Load Bearing Capacity per Shelf (UDL): 150 Kgs Single Faced Fixed(A) (5mx0.38mx2.1m)Nos108000.0108000.01.0FalseNoneNoneFalseNoneFalse108000.00
3922035151273NoneBOQ195BAY MOBILE RACK COMPACTOR Total no.of Racks of size 1980mm H X 1000mm W X 380mm D with 5 compartment-80 Nos, Capacity of Flat Files considering 25mm thickness-16000 files (OR) Capacity of Box Files considering 90mm thickness-4480 files, Epoxy Powder Coated Finish, Load Bearing Capacity per Shelf (UDL): 150 Kgs Double Faced Movable (B) (5mx0.76mx2.1m)Nos210000.0210000.05.0FalseNoneNoneFalseNoneFalse1050000.00
3922036151273NoneBOQ1965 BAY MOBILE RACK COMPACTOR Total no.of Racks of size 1980mm H X 1000mm W X 380mm D with 5 compartment-80 Nos, Capacity of Flat Files considering 25mm thickness-16000 files (OR) Capacity of Box Files considering 90mm thickness-4480 files, Epoxy Powder Coated Finish, Load Bearing Capacity per Shelf (UDL): 150 Kgs Single Faced Movable (C ) (5mx0.45mx2.1m)Nos118200.0118200.01.0FalseNoneNoneFalseNoneFalse118200.00
3922037151273NoneBOQ197Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum249.26249.2641.0FalseNoneNoneFalseNoneFalse10219.660
3922038151273NoneBOQ198Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth exceeding 1.5m, but not exceeding 3 mCum266.77266.7741.0FalseNoneNoneFalseNoneFalse10937.570
3922039151273NoneBOQ199Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum273.98273.9827.0FalseNoneNoneFalseNoneFalse7397.460
3922040151273NoneBOQ200Providing and laying in position Cement Concrete for levelling course for all works in foundation The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregatesCum5833.925833.923.0FalseNoneNoneFalseNoneFalse17501.760
3922041151273NoneBOQ201Providing and laying in position Reinforced cement concrete for all Foundation works The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6526.086526.0818.5FalseNoneNoneFalseNoneFalse120732.480
3922042151273NoneBOQ202Shuttering Work for combined FootingCum195.78195.786.91FalseNoneNoneFalseNoneFalse1352.83980
3922043151273NoneBOQ203Shuttering Work for retaining wallCum652.61652.618.23FalseNoneNoneFalseNoneFalse5370.98030
3922044151273NoneBOQ204Shuttering Work for SlabCum3263.043263.042.9FalseNoneNoneFalseNoneFalse9462.8160
3922045151273NoneBOQ205Supplying, fitting and B32placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification separately) a) Stilt FloorTonne92140.7192140.711.966FalseNoneNoneFalseNoneFalse181148.635860
3922046151273NoneBOQ206Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification.Sqm522.21522.2156.0FalseNoneNoneFalseNoneFalse29243.760
3922047151273NoneBOQ207Providing and laying in position Cement Concrete for levelling course for all works in foundation The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates a) Stilt FloorCum6403.516403.512.0FalseNoneNoneFalseNoneFalse12807.020
3922048151273NoneBOQ208Supplying and fixing of heavy duty SFRC manhole cover with frame 560MM size for underground tank.Each5500.05500.02.0FalseNoneNoneFalseNoneFalse11000.00
3922049151273NoneBOQ209Providing and fixing of PVC Rungs footrest in under ground tanks / manhole using M20 concrete bed blocks for masonry walls or during construction for RCC surfaces, including cost of materials, labour, curing etc. complete as per specifications.Each300.0300.08.0FalseNoneNoneFalseNoneFalse2400.00
3922050151273NoneBOQ210UGT/OHT (inside) waterproofing with Anti-microbial Coating Providing and Applying two component, water-based food grade epoxy resin coating on inside surface of Potable water tank having anti-algae, antifungal, Non-toxic, hygiene cum damp-proof coating Certified by CFTRI as per 21 CFR 175 300 of US FDA, having mixing Ratio (Base: Hardener: Water) 1:1:1 to be applied @ 0.35 Kg/m2 in 2 coats Ensure that this coating is applied over the protective plaster, and that Item No 4 is completed across the entire surface prior to applying the protective plaster The Waterproofing material shall have Specific Gravity: 1.2, Water vapor permeance: 244.48 g/m2/24 hrs, as per IS 7809/Pt 2/1977, Adhesion strength: 2 N/mm2 as per ASTM D 4541: 02 The finished cost to include surface preparation completely as per specification.Sqm1723.191723.1956.0FalseNoneNoneFalseNoneFalse96498.640
3922051151273NoneBOQ211Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum249.26249.2644.0FalseNoneNoneFalseNoneFalse10967.440
3922052151273NoneBOQ212Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth exceeding 1.5m, but not exceeding 3 mCum266.77266.7748.0FalseNoneNoneFalseNoneFalse12804.960
3922053151273NoneBOQ213Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum273.98273.9848.0FalseNoneNoneFalseNoneFalse13151.040
3922054151273NoneBOQ214Concrete, Formwork & reinforcement Providing and laying in position Cement Concrete for levelling course for all works in foundation The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregatesCum5833.925833.923.56FalseNoneNoneFalseNoneFalse20768.75520
3922055151273NoneBOQ215Providing and laying in position Cement Concrete for levelling course for all works in foundation The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates a) Stilt FloorCum6403.516403.510.5FalseNoneNoneFalseNoneFalse3201.7550
3922056151273NoneBOQ216Providing and laying in position Reinforced cement concrete for all Foundation works The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6526.086526.0815.5535FalseNoneNoneFalseNoneFalse101503.385280
3922057151273NoneBOQ217Addtionalities for Form Work for Combined Footing @3%Cum199.58199.585.0465FalseNoneNoneFalseNoneFalse1007.180470
3922058151273NoneBOQ218Addtionalities for Form Work for Wall@ 10%Cum627.8627.87.27FalseNoneNoneFalseNoneFalse4564.1060
3922059151273NoneBOQ219Addtionalities for Form Work for Roof Beam, Lintel Beam @ 60%Cum3766.773766.770.36FalseNoneNoneFalseNoneFalse1356.03720
3922060151273NoneBOQ220Addtionalities for Form Work for Roof Slab @ 50%Cum3138.983138.982.872FalseNoneNoneFalseNoneFalse9015.150560
3922061151273NoneBOQ221Supplying, fitting and B32placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification separately) a) Stilt FloorTonne92140.7192140.711.73FalseNoneNoneFalseNoneFalse159403.42830
3922062151273NoneBOQ222Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specificationsSqm1267.931267.936.41FalseNoneNoneFalseNoneFalse8127.43130
3922063151273NoneBOQ223Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour, rolling, water, all materials, usage & all other appurtenaces required to complete the work.Cum488.22488.2229.89FalseNoneNoneFalseNoneFalse14592.89580
3922064151273NoneBOQ224Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling PlasteringSqm332.69332.699.99FalseNoneNoneFalseNoneFalse3323.57310
3922065151273NoneBOQ225Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm359.47359.4795.29FalseNoneNoneFalseNoneFalse34253.89630
3922066151273NoneBOQ226Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification.Sqm522.21522.2195.29FalseNoneNoneFalseNoneFalse49761.39090
3922067151273NoneBOQ227Providing and fixing of PVC Rungs footrest in under ground tanks / manhole using M20 concrete bed blocks for masonry walls or during construction for RCC surfaces, including cost of materials, labour, curing etc. complete as per specifications.Nos300.0300.08.0FalseNoneNoneFalseNoneFalse2400.00
3922068151273NoneBOQ228Supplying and fixing of heavy duty SFRC manhole cover with frame 560MM size for underground tank.Nos5500.05500.06.0FalseNoneNoneFalseNoneFalse33000.00
3922069151273NoneBOQ229Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum249.26249.26133.0FalseNoneNoneFalseNoneFalse33151.580
3922070151273NoneBOQ230Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum273.98273.9864.0FalseNoneNoneFalseNoneFalse17534.720
3922071151273NoneBOQ231Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C / Lindane 20% E.C @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm121.54121.54109.0FalseNoneNoneFalseNoneFalse13247.860
3922072151273NoneBOQ232Providing and laying in position Cement Concrete for levelling course for all works in foundation The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregatesCum5833.925833.9211.0FalseNoneNoneFalseNoneFalse64173.120
3922073151273NoneBOQ233Providing and laying in position Cement Concrete for levelling course for all works in foundation The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates a) Stilt FloorCum6403.516403.514.0FalseNoneNoneFalseNoneFalse25614.040
3922074151273NoneBOQ234Providing and laying in position Reinforced cement concrete for all Foundation works The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum6526.086526.0813.0FalseNoneNoneFalseNoneFalse84839.040
3922075151273NoneBOQ235Addtionalities for Form Work for Isolated Footing @8%Cum522.09522.0910.0FalseNoneNoneFalseNoneFalse5220.90
3922076151273NoneBOQ236Addtionalities for Form Work for Columns @ 70%Cum4310.864310.863.0FalseNoneNoneFalseNoneFalse12932.580
3922077151273NoneBOQ237Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7048.297048.299.0FalseNoneNoneFalseNoneFalse63434.610
3922078151273NoneBOQ238Addtionalities for Form Work for Plinth Beam @ 50%Cum3524.143524.144.0FalseNoneNoneFalseNoneFalse14096.560
3922079151273NoneBOQ239Addtionalities for Form Work for Columns @ 70%Cum4310.864310.865.0FalseNoneNoneFalseNoneFalse21554.30
3922080151273NoneBOQ240Supplying, fitting and B32placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification separately) a) Stilt FloorTonne92140.7192140.712.105FalseNoneNoneFalseNoneFalse193956.194550
3922081151273NoneBOQ241Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6580.676580.6729.0FalseNoneNoneFalseNoneFalse190839.430
3922082151273NoneBOQ242Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge.Sqm262.65262.6554.0FalseNoneNoneFalseNoneFalse14183.10
3922083151273NoneBOQ243Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specificationsSqm1267.931267.93132.72FalseNoneNoneFalseNoneFalse168279.66960
3922084151273NoneBOQ244Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc as required In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg140.08140.081802.0FalseNoneNoneFalseNoneFalse252424.160
3922085151273NoneBOQ245Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External wall plasteringSqm287.37287.37341.0FalseNoneNoneFalseNoneFalse97993.170
3922086151273NoneBOQ246Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. & Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge External Wall PaintSqm146.26146.26341.0FalseNoneNoneFalseNoneFalse49874.660
3922087151273NoneBOQ247Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm118.45118.4536.04FalseNoneNoneFalseNoneFalse4268.9380
3922088151273NoneBOQ248Supplying heavy gauge PVC conduit pipe ……mm dia......mm thick confirming to IS 2509 with suitable size bends, metals/PVC junction boxes, adhesives paste etc. and running before concreting the slab The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures run with 18SWG GI fish wire wherever necessary a) 19/20 mm dia 2mm thickRmtr67.9867.98300.0FalseNoneNoneFalseNoneFalse20394.00
3922089151273NoneBOQ249Supplying heavy gauge PVC conduit pipe ……mm dia......mm thick confirming to IS 2509 with suitable size bends, metals/PVC junction boxes, adhesives paste etc. and running before concreting the slab The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures run with 18SWG GI fish wire wherever necessary b) 25mm dia 2mm thickRmtr80.3480.34600.0FalseNoneNoneFalseNoneFalse48204.00
3922090151273NoneBOQ250Supplying heavy gauge PVC conduit pipe ……mm dia......mm thick confirming to IS 2509 with suitable size bends, metals/PVC junction boxes, adhesives paste etc. and running before concreting the slab The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures run with 18SWG GI fish wire wherever necessary c) 32mm dia 2.5mm thickRmtr106.09106.0950.0FalseNoneNoneFalseNoneFalse5304.50
3922091151273NoneBOQ251Supplying heavy gauge PVC conduit pipe ……dia....mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesives paste etc. and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws a) 19/20 mm dia 2mm thickRmtr71.0771.0760.0FalseNoneNoneFalseNoneFalse4264.20
3922092151273NoneBOQ252Supplying heavy gauge PVC conduit pipe ……dia....mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesives paste etc. and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws b) 25mm dia 2mm thickRmtr83.4383.43150.0FalseNoneNoneFalseNoneFalse12514.50
3922093151273NoneBOQ253Supplying heavy gauge PVC conduit pipe ……dia....mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesives paste etc. and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws c) 32mm dia 2.5mm thickRmtr109.18109.1830.0FalseNoneNoneFalseNoneFalse3275.40
3922094151273NoneBOQ254Supplying heavy gauge PVC conduit pipe ……dia....mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesives paste etc. and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws d) 40mm dia 2.5mm thickRmtr153.47153.4720.0FalseNoneNoneFalseNoneFalse3069.40
3922095151273NoneBOQ255Supplying heavy gauge PVC conduit pipe……dia.....mm thick with suitable size bends, metal junction boxes, adhesive paste etc By groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary a) 19/20 mm dia 2mm thickRmtr70.0470.0475.0FalseNoneNoneFalseNoneFalse5253.00
3922096151273NoneBOQ256Supplying heavy gauge PVC conduit pipe……dia.....mm thick with suitable size bends, metal junction boxes, adhesive paste etc By groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary b) 25mm dia 2mm thickRmtr81.3781.37125.0FalseNoneNoneFalseNoneFalse10171.250
3922097151273NoneBOQ257Supplying heavy gauge PVC conduit pipe……dia.....mm thick with suitable size bends, metal junction boxes, adhesive paste etc By groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary c) 32mm dia 2.5mm thickRmtr101.97101.9710.0FalseNoneNoneFalseNoneFalse1019.70
3922098151273NoneBOQ258Supplying heavy gauge PVC conduit pipe……dia.....mm thick with suitable size bends, metal junction boxes, adhesive paste etc By groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary d) 40mm dia 2.5mm thickRmtr143.17143.1710.0FalseNoneNoneFalseNoneFalse1431.70
3922099151273NoneBOQ259Supplying and fixing PVC/metal conduit deep junction box. a) 19/20mm deep junction boxEach50.4750.4725.0FalseNoneNoneFalseNoneFalse1261.750
3922100151273NoneBOQ260Supplying and fixing PVC/metal conduit deep junction box. b) 25mm deep junction boxEach57.6857.6865.0FalseNoneNoneFalseNoneFalse3749.20
3922101151273NoneBOQ261Supplying and fixing PVC/metal conduit deep junction box. c) 32mm deep junction boxEach62.8362.835.0FalseNoneNoneFalseNoneFalse314.150
3922102151273NoneBOQ262Extra for Groove cutting in brick wall/cc floor to the suitable depth for concealing of Conduit/GI pipe and plastering, finishing the wall upto wall surface complete a) upto 50mm conduit in CC FloorRmtr71.0771.0750.0FalseNoneNoneFalseNoneFalse3553.50
3922103151273NoneBOQ263Supplying PVC flexible conduit pipe….mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm..using NF screws and on either end of the pipe terminated completely a) 25 mmRmtr22.6622.6675.0FalseNoneNoneFalseNoneFalse1699.50
3922104151273NoneBOQ264Supplying and fixing Metal fan box with round hookNos120.51120.5115.0FalseNoneNoneFalseNoneFalse1807.650
3922105151273NoneBOQ265Point wiring using copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet (For Light, fan point) a) Short point up to 3Mtr from tapping point to out let via switch boxPoint277.07277.0715.0FalseNoneNoneFalseNoneFalse4156.050
3922106151273NoneBOQ266Point wiring using copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet (For Light, fan point) b) Medium point above 3Mtr up to 6Mtrs from tapping point to out let via switch boxPoint390.37390.3720.0FalseNoneNoneFalseNoneFalse7807.40
3922107151273NoneBOQ267Point wiring using copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet (For Light, fan point) c) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch boxPoint571.65571.6535.0FalseNoneNoneFalseNoneFalse20007.750
3922108151273NoneBOQ268Point wiring using copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet (For Light, fan point) d) Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switch boxPoint697.31697.3130.0FalseNoneNoneFalseNoneFalse20919.30
3922109151273NoneBOQ269Point wiring using copper wire without switch Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1 x1.0Sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS 694: and latest amendments) with out control switch shall be fixed on the existing plastic sheet / gland box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet (For Light, fan point) e) Three outlet in a row, above 6Mtr up to 10Mtr from tapping point to out let via switches boxPoint1018.671018.6710.0FalseNoneNoneFalseNoneFalse10186.70
3922110151273NoneBOQ270Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments The cost should inlcude Crimping lugs and termination a) 1.5 sqmmRmtr26.7826.78300.0FalseNoneNoneFalseNoneFalse8034.00
3922111151273NoneBOQ271Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments The cost should inlcude Crimping lugs and termination b) 2.5 sqmmRmtr43.2643.261100.0FalseNoneNoneFalseNoneFalse47586.00
3922112151273NoneBOQ272Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments The cost should inlcude Crimping lugs and termination c) 4 sqmmRmtr64.8964.89700.0FalseNoneNoneFalseNoneFalse45423.00
3922113151273NoneBOQ273Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments The cost should inlcude Crimping lugs and termination d) 6 sqmmRmtr94.7694.76100.0FalseNoneNoneFalseNoneFalse9476.00
3922114151273NoneBOQ274Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V Grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with as per IS-694: confirming to latest amendments The cost should inlcude Crimping lugs and termination e) 10 sqmmRmtr172.01172.01100.0FalseNoneNoneFalseNoneFalse17201.00
3922115151273NoneBOQ275Supplying and Drawing flexible multicore cable manufactured with electrolytic grade flexible copper with low conductor confirming to table 3 class 5 of IS:8130-1984 and (virgin) PVC insulation and sheathed suitable for working voltage upto 1100volts as per IS-694:1990 The cost should inlcude Crimping lugs and termination. a) 4Cx6.0SqmmRmtr231.75231.7550.0FalseNoneNoneFalseNoneFalse11587.50
3922116151273NoneBOQ276SWITCHES, SOCKETS & ACCESSORIES Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall a) 1-2 WayEach142.14142.1430.0FalseNoneNoneFalseNoneFalse4264.20
3922117151273NoneBOQ277Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall b) 1-3 WayEach163.77163.7725.0FalseNoneNoneFalseNoneFalse4094.250
3922118151273NoneBOQ278Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall c) 4 WayEach182.31182.315.0FalseNoneNoneFalseNoneFalse911.550
3922119151273NoneBOQ279Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall d) 6 WayEach226.6226.615.0FalseNoneNoneFalseNoneFalse3399.00
3922120151273NoneBOQ280Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall e) 8 WayEach268.83268.8335.0FalseNoneNoneFalseNoneFalse9409.050
3922121151273NoneBOQ281Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall f) 10-12 WayEach328.57328.575.0FalseNoneNoneFalseNoneFalse1642.850
3922122151273NoneBOQ282Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall g) 18 WayEach417.15417.155.0FalseNoneNoneFalseNoneFalse2085.750
3922123151273NoneBOQ283Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws, bolts nuts etc. complete on the existing metal/ metal PVC box a) 1 to 2 ModuleEach141.11141.1130.0FalseNoneNoneFalseNoneFalse4233.30
3922124151273NoneBOQ284Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws, bolts nuts etc. complete on the existing metal/ metal PVC box b) 3 ModuleEach165.83165.8325.0FalseNoneNoneFalseNoneFalse4145.750
3922125151273NoneBOQ285Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws, bolts nuts etc. complete on the existing metal/ metal PVC box c) 4 ModuleEach180.25180.255.0FalseNoneNoneFalseNoneFalse901.250
3922126151273NoneBOQ286Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws, bolts nuts etc. complete on the existing metal/ metal PVC box d) 6 ModuleEach241.02241.0215.0FalseNoneNoneFalseNoneFalse3615.30
3922127151273NoneBOQ287Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws, bolts nuts etc. complete on the existing metal/ metal PVC box e) 8 ModuleEach292.52292.5235.0FalseNoneNoneFalseNoneFalse10238.20
3922128151273NoneBOQ288Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws, bolts nuts etc. complete on the existing metal/ metal PVC box f) 10-12 ModuleEach354.32354.325.0FalseNoneNoneFalseNoneFalse1771.60
3922129151273NoneBOQ289Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos of machine screws, bolts nuts etc. complete on the existing metal/ metal PVC box g)18 ModuleEach470.71470.715.0FalseNoneNoneFalseNoneFalse2353.550
3922130151273NoneBOQ290Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 a) 6 Amps one wayEach105.06105.06150.0FalseNoneNoneFalseNoneFalse15759.00
3922131151273NoneBOQ291Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 b) 6 Amps Two wayEach170.98170.9810.0FalseNoneNoneFalseNoneFalse1709.80
3922132151273NoneBOQ292Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 c) 6Amps 3way socketEach176.13176.13105.0FalseNoneNoneFalseNoneFalse18493.650
3922133151273NoneBOQ293Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 d) Stepped fan regulator Two moduleEach367.71367.7115.0FalseNoneNoneFalseNoneFalse5515.650
3922134151273NoneBOQ294Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 e) 32A,DP,SwitchEach335.78335.785.0FalseNoneNoneFalseNoneFalse1678.90
3922135151273NoneBOQ295Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 f) 16Amps one way switchEach185.4185.445.0FalseNoneNoneFalseNoneFalse8343.00
3922136151273NoneBOQ296Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 g) 6/16Amps universal socketEach243.08243.0820.0FalseNoneNoneFalseNoneFalse4861.60
3922137151273NoneBOQ297CONTROL SWITCH GEARS & ACCESSORIES Supplying push button operated, direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet steel or iron clad enclosure and fixing the same to suitable capacity wires for 400/440 volts 3 phase motor/single phase motor upto 5 HPEach1984.811984.812.0FalseNoneNoneFalseNoneFalse3969.620
3922138151273NoneBOQ298Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. a) 6-32Amps SPEach427.45427.4550.0FalseNoneNoneFalseNoneFalse21372.50
3922139151273NoneBOQ299Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. b) 40Amps DPEach1091.81091.84.0FalseNoneNoneFalseNoneFalse4367.20
3922140151273NoneBOQ300Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. c) 5-32Amps TP / TPNEach1768.511768.513.0FalseNoneNoneFalseNoneFalse5305.530
3922141151273NoneBOQ301Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. d) 40Amps TPNEach3135.323135.322.0FalseNoneNoneFalseNoneFalse6270.640
3922142151273NoneBOQ302Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. e) 63Amps TPNEach3180.643180.641.0FalseNoneNoneFalseNoneFalse3180.640
3922143151273NoneBOQ303Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts ,nuts etc. with provision for fixing suitable type capacity MCB'S single phase / 3 phase / single door with powder coated painting Made out of 14 SWG MS Enclosure a) Double Door 4 Way SP & NEach1569.721569.721.0FalseNoneNoneFalseNoneFalse1569.720
3922144151273NoneBOQ304Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts ,nuts etc. with provision for fixing suitable type capacity MCB'S single phase / 3 phase / single door with powder coated painting Made out of 14 SWG MS Enclosure b) Double Door 8 Way SP & NEach1909.621909.621.0FalseNoneNoneFalseNoneFalse1909.620
3922145151273NoneBOQ305Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts ,nuts etc. with provision for fixing suitable type capacity MCB'S single phase / 3 phase / single door with powder coated painting Made out of 14 SWG MS Enclosure c) Double Door 12 Way SP & NEach2398.872398.872.0FalseNoneNoneFalseNoneFalse4797.740
3922146151273NoneBOQ306Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts ,nuts etc. with provision for fixing suitable type capacity MCB'S single phase / 3 phase / single door with powder coated painting Made out of 14 SWG MS Enclosure d) Double Door 4 Way TP & NEach4159.144159.142.0FalseNoneNoneFalseNoneFalse8318.280
3922147151273NoneBOQ307Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. a) 40Amps 2 poleEach4695.774695.772.0FalseNoneNoneFalseNoneFalse9391.540
3922148151273NoneBOQ308Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. b) 32-40Amps 4 poleEach5301.415301.412.0FalseNoneNoneFalseNoneFalse10602.820
3922149151273NoneBOQ309Supplying and fixing angle iron frame work fabricated out of M.S angle iron ….and M.S flat with bolts, washers etc… and painted with 2 coats of red oxide and then two coats of approved paint. 40x40x6Rmtr314.15314.1515.0FalseNoneNoneFalseNoneFalse4712.250
3922150151273NoneBOQ310EARTHING AND L.T U.G CABLES Supplying fixing and wiring earth electrode for grounding of DG Sets etc using 40mm dia 2.9mm thick 2.5mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber The connection from the electrode is to be established through GI strip using GI bolts and nuts.Each4383.684383.684.0FalseNoneNoneFalseNoneFalse17534.720
3922151151273NoneBOQ311Supplying and running of GI / Copper strips for grounding connections, using necessary fixing materials as required. a) GI strip 25x3mmRmtr84.4684.4680.0FalseNoneNoneFalseNoneFalse6756.80
3922152151273NoneBOQ312Supplying and running of GI / Copper strips for grounding connections, using necessary fixing materials as required. b) 600x600x3mm GI PlateRmtr901.25901.254.0FalseNoneNoneFalseNoneFalse3605.00
3922153151273NoneBOQ313Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc.. 8 SWG GI wire.MT77291.277291.20.1FalseNoneNoneFalseNoneFalse7729.120
3922154151273NoneBOQ314Supplying of 1.1KV LT UG Aluminium cable XLPE insulated, PVC extruded inner sheathed, armourd UG LT cable as per the IS - 1554 (part-1) or IS-7098 part-1, Armoring strip thickness in average + 5% and resistivity 14 Ohms/Kms (Max) as per IS -3975. a) 3.5 core 25 sq.mmKm143735.47143735.470.05FalseNoneNoneFalseNoneFalse7186.77350
3922155151273NoneBOQ315Labour charges for laying of 1.1 KV class UG cable in the existing trench GI pipe / stoneware pipe / on wall / on pole as required. On wall / Structure. a) 2.5 sqmm to 25 sqmmKm21512.5821512.580.05FalseNoneNoneFalseNoneFalse1075.6290
3922156151273NoneBOQ316Supplying and fixing of heavy duty cable glands suitable for UG cable of1.1 KV class (metal only) a) 25mmEach81.3781.372.0FalseNoneNoneFalseNoneFalse162.740
3922157151273NoneBOQ317Aluminium End Terminal (Lug) a) 2.5 to 10 sq.mmEach2.062.06150.0FalseNoneNoneFalseNoneFalse309.00
3922158151273NoneBOQ318Supplying and termination of Heavy Duty Copper Terminal long barrel. a) 25 sq.mm Long barrelEach27.8127.8110.0FalseNoneNoneFalseNoneFalse278.10
3922159151273NoneBOQ319Supplying and fixing 2mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required. a) 150x50mmRmtr476.89476.895.0FalseNoneNoneFalseNoneFalse2384.450
3922160151273NoneBOQ320Fixing all types and all capacities fluorescent /false ceiling/spot light/CFL/LED fittings indoor on the wall / ceiling / rafters / girders using 23 / 0.00076 " twin twisted PVC insulated wires, required nos of round blocks and clamps On wall / ceiling / Rafters / GirdersEach125.66125.66130.0FalseNoneNoneFalseNoneFalse16335.80
3922161151273NoneBOQ321Using 2 Mtr long 19mm 18SWG enamelled braised conduit of two nos rod pendent with ball socket with check nuts all nickel painted.Each587.1587.110.0FalseNoneNoneFalseNoneFalse5871.00
3922162151273NoneBOQ322Extra length of GI pipe of class b 19mm dia for down rod.Each202.91202.9110.0FalseNoneNoneFalseNoneFalse2029.10
3922163151273NoneBOQ323Fixing a ceiling/wall mounting fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing a 5 amps ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each324.45324.4515.0FalseNoneNoneFalseNoneFalse4866.750
3922164151273NoneBOQ324Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire.Each506.76506.7610.0FalseNoneNoneFalseNoneFalse5067.60
3922165151273NoneBOQ325FIRE SAFETY WORKS Supplying of two buckets standalong with bucketsEach1133.01133.01.0FalseNoneNoneFalseNoneFalse1133.00
3922166151273NoneBOQ326Supplying of HAND GLOVESPair1004.251004.251.0FalseNoneNoneFalseNoneFalse1004.250
3922167151273NoneBOQ327Supplying of first aid boxEach618.0618.01.0FalseNoneNoneFalseNoneFalse618.00
3922168151273NoneBOQ328Supplying of SAFETY MASKEach154.5154.51.0FalseNoneNoneFalseNoneFalse154.50
3922169151273NoneBOQ329Supplying of FIRST AID CHART with laminationEach412.0412.01.0FalseNoneNoneFalseNoneFalse412.00
3922170151273NoneBOQ330Supplying and installation of RUBBER MAT 1mtx1mt-10mm ThickEach1957.01957.01.0FalseNoneNoneFalseNoneFalse1957.00
3922171151273NoneBOQ331FIRE EXTINGUISHERS - Supply & Providing 4.5Kg C02 Gas Type aluminium body Squeeze grip Fire Extinugisher, Trolley Mounted, Easy Weight Management, Used Unused Mechanism, Squeeze Grip, Gross Weight 11.16Kg empty Weight 6.66Kg Can Height 860MM Diameter 140MM, Discharge Time less than10 Sees, Controllable discharge mechanism, Applicable on Class 8&C Fire, 8 Rating 138, Can Constuction : Cold Impact Extrusion, Valve Construction : Forging & Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Aluminium metal ISO & PESO Approved, 3 Year Warranty including cost of materials, labour, usage charges of machinery complete as per specifications complete.Each7725.07725.01.0FalseNoneNoneFalseNoneFalse7725.00
3922172151273NoneBOQ332LIGHT FIXTURES , FANS Supplying and fixing of LED Bulkhead of 10W with IP65 protection and IK 08 impact resistance suitable for surface and wall mounting applications.Each867.26867.2615.0FalseNoneNoneFalseNoneFalse13008.90
3922173151273NoneBOQ333Supplying of 2' feet - LED PVC Square Batten …W with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with CRI greater than 8 Power Input : 220-240V @ 50 Hz & power factor 0.9 along with CE approved drivers 2 years warranty against any manufacturing defect working under standard electrical condition. a) Led light fitting 2' - 9 / 10 wattsEach567.53567.5310.0FalseNoneNoneFalseNoneFalse5675.30
3922174151273NoneBOQ334Supplying of 2' feet - LED PVC Square Batten …W with high quality diffuser with life of 25000 burning hours & 70% lumen maintenance with CRI greater than 8 Power Input : 220-240V @ 50 Hz & power factor 0.9 along with CE approved drivers 2 years warranty against any manufacturing defect working under standard electrical condition. b) Led light fitting 4' - 20 / 22 wattsEach710.7710.720.0FalseNoneNoneFalseNoneFalse14214.00
3922175151273NoneBOQ335Supply of round/square recess/surface mounted rolling type LED Down light with.....W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80 Power Input: 220-240V @50/60Hz & Power factor greater than0.9 along with CE approved 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 5-6WEach588.13588.1310.0FalseNoneNoneFalseNoneFalse5881.30
3922176151273NoneBOQ336Supply of round/square recess/surface mounted rolling type LED Down light with.....W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained by circular wire spring, with Life of 25000 burning hours & 70% lumen maintenance with CRI greater than 80 Power Input: 220-240V @50/60Hz & Power factor greater than0.9 along with CE approved 2years Warranty against any manufacturing defect working under standard electrical condition LED square or round down light 15-18WEach1363.721363.7225.0FalseNoneNoneFalseNoneFalse34093.00
3922177151273NoneBOQ337Supply of 2'X2' LED recessed / surface luminaire with watts system wattage Housing shall be with pressure die cast aluminum alloy with corrosion proof resistant polyester powder coated Driver operates with voltage range from 100V to 270V 50/60Hz with short circuit, overloaded, & miswiring Lumen maintenance of 70% @ 50000 Hrs injection moulded polycarbonate diffuser for better mechanical stability, light transmission & avoid pot hole effect Junction temperature shall be lesser than 70 deg Celsius Driver is on constant current driver driver @ 0.06A with PF greater than 0.92 with line voltage @220-240V @ 50/60Hz, driver efficiency greater than85% & THDlesser than15% LEd efficiency greater than 130ml/w at 1w and fixture efficiency greater than 75ml/w with CRI greater than 75 with injection moulded polycarbonate lens 5 years warranty against any manufacturing defect working under standard electrical condition LED MODULAR DOWN LIGHT 2'x2' 36WEach4689.594689.5935.0FalseNoneNoneFalseNoneFalse164135.650
3922178151273NoneBOQ338FANS Supplying exhaust fan of 1440RPM heavy duty with bracket blades complete for lighting duty suitable to operate on 230V 50Hz, AC supply. 12" sweep (300mm)Each3058.073058.0710.0FalseNoneNoneFalseNoneFalse30580.70
3922179151273NoneBOQ339Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/79 and also comply with IS:1709/1984 with latest amendment, Rated voltage 220 V/ 50 Hz, Rated power input 48 W +/- 10 %, Rated current As per IS:374/79, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value greater or equal to 4.2 CMM / Watt, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201 , as per IS specification, Motor wdg Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 Volts, Insulation resistance Shall not be less than Two Mega Ohms (2 M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, watt& current , Air Delivery & Fan Speed as per IS:374/1979 with latest amendment, 2 year manufacturer Warranty.. 5 STAR 48" Sweep 5 Star (1200mm)Each2757.312757.3115.0FalseNoneNoneFalseNoneFalse41359.650
3922180151273NoneBOQ340Supplying of Surface / recess mounting non integrated type LED down light …W luminaire comprising of pressure decast/extruded aluminum housing, with spring loaded false ceiling clamps, LED of Power / COB with CCT 6500 degree K, CRI greater than70% efficacy greater than100 lumen per watt, 120degree beam spread, lifegreater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80 The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly. with PF greater than 0.95, power loss should lesser than 5% of lamp wattage. short circuit & open circuit protection to be integrated in the circuit THD Less then 20%, Life as per LM 79, The operating input voltage should be between 130 to 275 volts, BIS Approved and tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 10-12WEach1307.071307.078.0FalseNoneNoneFalseNoneFalse10456.560
3922181151273NoneBOQ341Supply of 2'X2' LED recessed / surface luminaire with watts system wattage Housing shall be with pressure die cast aluminum alloy with corrosion proof resistant polyester powder coated Driver operates with voltage range from 100V to 270V 50/60Hz with short circuit, overloaded, & miswiring Lumen maintenance of 70% @ 50000 Hrs injection moulded polycarbonate diffuser for better mechanical stability, light transmission & avoid pot hole effect Junction temperature shall be lesser than 70 deg Celsius Driver is on constant current driver driver @ 0.06A with PF greater than 0.92 with line voltage @220-240V @ 50/60Hz, driver efficiency greater than85% & THDlesser than15% LEd efficiency greater than 130ml/w at 1w and fixture efficiency greater than 75ml/w with CRI greater than 75 with injection moulded polycarbonate lens 5 years warranty against any manufacturing defect working under standard electrical condition LED modular down light 2'x2' 36 WEach4689.594689.594.0FalseNoneNoneFalseNoneFalse18758.360
3922182151273NoneBOQ342LT Panel Works Fabricating supplying and mounting MS box made out … SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint and Powder coating etc. complete 14SWGSq CM0.520.5235000.0FalseNoneNoneFalseNoneFalse18200.00
3922183151273NoneBOQ343Supplying and fixing angle iron frame work fabricated out of M.S angle iron… and M S flat …….With bolts, washers etc. and painted with 2 coats of red oxide and then two coats of approved paint 75 x 150 x 75 x 6 mm C channelRmtr953.78953.782.0FalseNoneNoneFalseNoneFalse1907.560
3922184151273NoneBOQ344Supplying …….amps rated 3 phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M S flat frame work in existing panel board The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc. complete. 100Amps 4x30x10mm Aluminum Strips.Rmtr2538.952538.951.0FalseNoneNoneFalseNoneFalse2538.950
3922185151273NoneBOQ345Supplying of multi function Meter digital three line back light LCD type display of voltage, Current, frequency, Power, power factor, KVA, KWH, KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required wit communication Port and class 0.5s accuracy.Each9594.459594.451.0FalseNoneNoneFalseNoneFalse9594.450
3922186151273NoneBOQ346Supplying, fixing and wiring 50/5 to 400/4Amps 5VA burden Current Transformer Class 0.5 accuracy with tape wound.Each578.86578.862.0FalseNoneNoneFalseNoneFalse1157.720
3922187151273NoneBOQ347Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220V AC, 50Hz 12/24V DCEach530.45530.453.0FalseNoneNoneFalseNoneFalse1591.350
3922188151273NoneBOQ348Supplying, fixing and wiring 3 Digit Digital Ammeter/VoltmeterEach1467.751467.751.0FalseNoneNoneFalseNoneFalse1467.750
3922189151273NoneBOQ349Supplying of on load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply (Open Execution) 63AmpsEach5644.45644.41.0FalseNoneNoneFalseNoneFalse5644.40
3922190151273NoneBOQ350Supply and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete Protection of overload and short circuit with thermal magnetic/micro processor releases and earth fault as per IS-13947 (Icu=Ics) FOUR POLE 63-100Amps 25kAEach6268.586268.581.0FalseNoneNoneFalseNoneFalse6268.580
3922191151273NoneBOQ351Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60899 6-32 Amps SPEach427.45427.454.0FalseNoneNoneFalseNoneFalse1709.80
3922192151273NoneBOQ352Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60899 40 Amps DPEach1091.81091.83.0FalseNoneNoneFalseNoneFalse3275.40
3922193151273NoneBOQ353Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60899 6-32 Amps TPNEach1768.511768.514.0FalseNoneNoneFalseNoneFalse7074.040
3922194151273NoneBOQ354Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' type curve, indicator ON/OFF, energy cross-3 with short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60899 40 Amps TPNEach3135.323135.323.0FalseNoneNoneFalseNoneFalse9405.960
3922195151273NoneBOQ355UPS, BATTERIES. Supplying, erecting, testing and commissioning of ON-LINE UPS System suitable for operation on 230V Input and 230V, Output, 50Hz, A/C supply with Isolation Transformer all accessories complete and excluding batteries and wiring complete. 5 KVA ONLINE UPSEach70434.4970434.491.0FalseNoneNoneFalseNoneFalse70434.490
3922196151273NoneBOQ356Supplying installation testing and commissioning of 12V DC, AH batteries in poly propylene container for U.P.S sealed maintenance free batteries 100 AH CapacityEach12802.912802.96.0FalseNoneNoneFalseNoneFalse76817.40
3922197151273NoneBOQ357CAMERAS & ACCESSORIES Supply, Installation, Testing & Commissioning of 1/3" progressive scan CMOS, Fixed 4.0 megapixel, IP based Colour camera, Up to 30 m IR range, Color: 0.01Lux, 1000TVL, Digital WDR (Wide Dynamic Range), 3D DNR (Digital Noise Reduction), PoE (Power over Ethernet/1 RJ45 10M/100M self-adaptive Ethernet port), IP67, Motion detection, Alarms (Video tampering, network disconnected, IP address conflicted), Protocols (TCP/IP, ICMP, HTTP, HTTPS, FTP, DHCP, DNS, DDNS, RTP, RTSP, RTCP, NTP, UPnP, SMTP, IGMP, 802.1X, QoS, IPv6, Bonjour), Standard (ONVIF(PROFILE S,PROFILE G),PSIA,CGI,ISAPI), General Function (Anti-flicker, heartbeat, mirror, password protection, privacy mask, watermark), with base box, other necessary accessories The cost shall includes end terminationsNos5665.05665.05.0FalseNoneNoneFalseNoneFalse28325.00
3922198151273NoneBOQ358Supply, Installation, Testing & Commissioning of 8port 10/100/1000 Smart POE Switch with 4 SFP (192W)for camera connection including all necessary accessories.Nos9785.09785.01.0FalseNoneNoneFalseNoneFalse9785.00
3922199151273NoneBOQ359Supply, Installation, Testing and Commissioning of NVR (Networkable Video Recorder) 8Channel NVR, Up to 8ch IP cameras input, Up to 5 Megapixels resolution recording, HDMI and VGA output at up to 1920x1080P resolution, HDD quota and group management 4 SATA, 3 USB, interface, 1 RJ 45 10 /100 /1000 Mbps self adaptive Ethernet interface, 4TB HDD/30Days recording storage, whichever is higher, support 10TB external HDD connected through SATA Ports DVR should have 2 external SATA Port, Alarm in 8 Alarm out 8, 100 240VAC, 6.3A, 50 60Hz, rack mountable, Password protection, Upto 8 simultaneous views from different DVRS on same LAN on single screen, etc with all necessary Accessories.Nos15450.015450.01.0FalseNoneNoneFalseNoneFalse15450.00
3922200151273NoneBOQ360Supply, Installation, Testing & Commissioning of HDMI, Display Monitor 32" high resolution, Monitor with all mounting bracket accessoriesNos25750.025750.01.0FalseNoneNoneFalseNoneFalse25750.00
3922201151273NoneBOQ361Supplying and drawing UTP-CAT 6E LAN cable.Rmtr39.1439.14150.0FalseNoneNoneFalseNoneFalse5871.00
3922202151273NoneBOQ362NETWORKING AND COMMUNICATION : Supplying and fixing of modular switch/Socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 Supplying and drawing UTP-CAT 6 LAN cable.Rmtr39.1439.14800.0FalseNoneNoneFalseNoneFalse31312.00
3922203151273NoneBOQ363Supplying and Drawing PVC flexible one pair telephone unarmoured tinned copper cable. a) 2 PairRmtr21.6321.63250.0FalseNoneNoneFalseNoneFalse5407.50
3922204151273NoneBOQ364Supplying and Drawing PVC flexible one pair telephone unarmoured tinned copper cable. b) 5 PairRmtr47.3847.3850.0FalseNoneNoneFalseNoneFalse2369.00
3922205151273NoneBOQ365Supplying and Drawing PVC flexible one pair telephone unarmoured tinned copper cable. c) 20 PairRmtr154.5154.510.0FalseNoneNoneFalseNoneFalse1545.00
3922206151273NoneBOQ366Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable RG-6.Rmtr45.3245.3260.0FalseNoneNoneFalseNoneFalse2719.20
3922207151273NoneBOQ367Supplying and Fixing of MDF Krone junction box with KRONE module / Telephone cable termination. 30 pairEach585.04585.042.0FalseNoneNoneFalseNoneFalse1170.080
3922208151273NoneBOQ368LIFT Design, supplying, erecting testing and commissioning of - passenger/ Bed-cum-passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional / international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc. With Out Machine Room - SS Finish ( 8 Passangers , 3 Stops)Each1502246.721502246.721.0FalseNoneNoneFalseNoneFalse1502246.720
3922209151273NoneBOQ369AIR CONDITION WORKS - Supplying erection, testing, commissioning of cassette type split air conditioners suitable for operation on single/three phase AC supply, hermetically sealed compressor with air cooled condenser motor capacitor start, capacitor run, relay and over load protection, one ceiling mounted indoor unit and one outdoor condenser unit including standard accessories covered with insulation tube including battery operated cordless unit. 3 TR Cassette 3 PhNos108270.51108270.512.0FalseNoneNoneFalseNoneFalse216541.020
3922210151273NoneBOQ370Installation charges of split/cassette type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support up to 4.0 ton split/cassette type A/C.Nos3270.253270.252.0FalseNoneNoneFalseNoneFalse6540.50
3922211151273NoneBOQ371Supplying and installation of insulated refrigrent copper tubing of 5/8" and 3/8" with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit Leak testing oil and gas charging for additional piping length of tube CassetteRmtr1688.171688.1750.0FalseNoneNoneFalseNoneFalse84408.50
3922212151273NoneBOQ372Extra for fabrication supply and fixing of stand fabricated using slotted angle/L.angle of size 6mmx50mm for mounting out door/indoor A C unit/BatteriesNos4951.214951.212.0FalseNoneNoneFalseNoneFalse9902.420
3922213151273NoneBOQ373Providing and fixing wash basin with C.I brackets, 15 mm C.P brass pillar taps, 32 mm C.P brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P brass pillar taps First FloorEach2981.52981.53.0FalseNoneNoneFalseNoneFalse8944.50
3922214151273NoneBOQ374Providing and fixing wash basin with C.I brackets, 15 mm C.P brass pillar taps, 32 mm C.P brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P brass pillar taps Second FloorEach3011.023011.022.0FalseNoneNoneFalseNoneFalse6022.040
3922215151273NoneBOQ375Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover,and cistern fittings, nuts, bolts and gasket etc complete First FloorEach11676.3311676.333.0FalseNoneNoneFalseNoneFalse35028.990
3922216151273NoneBOQ376Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover,and cistern fittings, nuts, bolts and gasket etc complete. Second FloorEach11791.9311791.932.0FalseNoneNoneFalseNoneFalse23583.860
3922217151273NoneBOQ377Providing and fixing CP Health faucet with flexible hose,CP Bibcock with 2 in 1 connectvity, wall flange, supporting hook with screws, fixing materials and sealant to all sides of wall flange complete. Make :Nos3000.03000.05.0FalseNoneNoneFalseNoneFalse15000.00
3922218151273NoneBOQ378Providing and fixing C.P brass bib cock of approved quality conforming to IS:8931 First FloorEach660.59660.592.0FalseNoneNoneFalseNoneFalse1321.180
3922219151273NoneBOQ379Providing and fixing C.P brass bib cock of approved quality conforming to IS:8931 Second FloorEach667.13667.132.0FalseNoneNoneFalseNoneFalse1334.260
3922220151273NoneBOQ380Providing and fixing C.P brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. First FloorEach754.22754.226.0FalseNoneNoneFalseNoneFalse4525.320
3922221151273NoneBOQ381Providing and fixing C.P brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. Second FloorEach761.69761.696.0FalseNoneNoneFalseNoneFalse4570.140
3922222151273NoneBOQ382Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P brass screws and washers complete. First FloorEach1269.171269.173.0FalseNoneNoneFalseNoneFalse3807.510
3922223151273NoneBOQ383Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P brass screws and washers complete. Second FloorEach1281.731281.732.0FalseNoneNoneFalseNoneFalse2563.460
3922224151273NoneBOQ384Supplying , shifting to the place of installation and fixing testing and commissioning of stainless steel soap dish 150 x 150mm including cutting and setting in walls with cement joints and making good the wall Make : JAQUAR Model No- ACN -1131NNos834.0834.05.0FalseNoneNoneFalseNoneFalse4170.00
3922225151273NoneBOQ385Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : 510x1040 mm bowl depth 250 mmNos5902.275902.271.0FalseNoneNoneFalseNoneFalse5902.270
3922226151273NoneBOQ386Providing and fixing Sink cock with swivel spout & wall flange, wall mountable made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class ( Premium )Nos3032.033032.034.0FalseNoneNoneFalseNoneFalse12128.120
3922227151273NoneBOQ387Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P brass flush pipe, spreaders with unions and clamps (all in C.P brass) with waste fitting as per IS : 2556, C.I trap with outlet grating and other couplings in C.P brass,including painting of fittings and cutting and making good the walls and floors wherever required Single half stall urinal with 5 litre P.V.C automatic flushing cistern each First FloorEach8990.278990.271.0FalseNoneNoneFalseNoneFalse8990.270
3922228151273NoneBOQ388Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P brass flush pipe, spreaders with unions and clamps (all in C.P brass) with waste fitting as per IS : 2556, C.I trap with outlet grating and other couplings in C.P brass,including painting of fittings and cutting and making good the walls and floors wherever required Single half stall urinal with 5 litre P.V.C automatic flushing cistern each Second FloorEach9079.299079.291.0FalseNoneNoneFalseNoneFalse9079.290
3922229151273NoneBOQ389Providing and fixing P.V.C waste pipe for sink or wash basin including P.V.C waste fittings complete. 40mm Dia First FloorRmtr91.5591.557.19FalseNoneNoneFalseNoneFalse658.24450
3922230151273NoneBOQ390Providing and fixing P.V.C waste pipe for sink or wash basin including P.V.C waste fittings complete. 40mm Dia Second FloorRmtr92.4592.459.6FalseNoneNoneFalseNoneFalse887.520
3922231151273NoneBOQ391Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excavation etc complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc for: PVC pipes 75mm dia. 6 kg/sqcm & class 3 First FloorRmtr228.87228.8712.0FalseNoneNoneFalseNoneFalse2746.440
3922232151273NoneBOQ392Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excavation etc complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc for: PVC pipes 75mm dia. 6 kg/sqcm & class 3 Second FloorRmtr231.13231.1312.0FalseNoneNoneFalseNoneFalse2773.560
3922233151273NoneBOQ393Supply and delivery at site special moulded variety 75 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments First FloorEach69.769.72.0FalseNoneNoneFalseNoneFalse139.40
3922234151273NoneBOQ394Supply and delivery at site special moulded variety 75 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments Second FloorEach70.3970.392.0FalseNoneNoneFalseNoneFalse140.780
3922235151273NoneBOQ395Supply and delivery at site special moulded variety 75 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments First FloorNos199.74199.742.0FalseNoneNoneFalseNoneFalse399.480
3922236151273NoneBOQ396Supply and delivery at site special moulded variety 75 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments Second FloorNos201.72201.722.0FalseNoneNoneFalseNoneFalse403.440
3922237151273NoneBOQ397Supply and delivery at site special moulded variety 75 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments First FloorNos121.72121.722.0FalseNoneNoneFalseNoneFalse243.440
3922238151273NoneBOQ398Supply and delivery at site special moulded variety 75 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments Second FloorNos122.92122.922.0FalseNoneNoneFalseNoneFalse245.840
3922239151273NoneBOQ399Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excavation etc complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc for: PVC pipes 110mm dia. 6 kg/sqcm & class 3Rmtr427.56427.5612.0FalseNoneNoneFalseNoneFalse5130.720
3922240151273NoneBOQ400Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excavation etc complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc for: PVC pipes 110mm dia. 6 kg/sqcm & class 3 Second FloorRmtr431.8431.812.0FalseNoneNoneFalseNoneFalse5181.60
3922241151273NoneBOQ401Supply and delivery at site special moulded variety 110 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments First FloorNos177.89177.892.0FalseNoneNoneFalseNoneFalse355.780
3922242151273NoneBOQ402Supply and delivery at site special moulded variety 110 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments Second FloorNos179.65179.652.0FalseNoneNoneFalseNoneFalse359.30
3922243151273NoneBOQ403Supply and delivery at site special moulded variety 110mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments First FloorNos314.17314.172.0FalseNoneNoneFalseNoneFalse628.340
3922244151273NoneBOQ404Supply and delivery at site special moulded variety 110mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments Second FloorNos317.28317.282.0FalseNoneNoneFalseNoneFalse634.560
3922245151273NoneBOQ405Supply and delivery at site special moulded variety 110 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments First FloorNos261.12261.122.0FalseNoneNoneFalseNoneFalse522.240
3922246151273NoneBOQ406Supply and delivery at site special moulded variety 110 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments Second FloorNos275.26275.262.0FalseNoneNoneFalseNoneFalse550.520
3922247151273NoneBOQ407Providing & fixing, testing and commissioning u PVC multi inlet floor trap 75mm dia conforming to IS 13592 with required P C C support placed to required level as per site condition complete..Nos552.0552.08.0FalseNoneNoneFalseNoneFalse4416.00
3922248151273NoneBOQ408Supplying and fixing PVC 'P' trap 110mm dia, of self cleansing design with or without vent arm complete including cutting and making good the walls and floorsNos732.0732.02.0FalseNoneNoneFalseNoneFalse1464.00
3922249151273NoneBOQ409Providing & Fixing in position heavy duty C P grating 125mm dia, with frame of below mentioned sizes including jointing and fixing material completeNos282.0282.010.0FalseNoneNoneFalseNoneFalse2820.00
3922250151273NoneBOQ410Providing and grouting sleeves made in beam/ slab to draw waste and soil lines at all floor level of the below mentioned sizes , including condcting water ponding test to ensure zero leakage with all leads and lifts complete Size : 150 mm diaNos720.0720.016.0FalseNoneNoneFalseNoneFalse11520.00
3922251151273NoneBOQ411Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete,As per direction of engineer in charge Concealed work including cutting chases and good the walls etc. 20 mm dia pipe nominal OD pipes First FloorRmtr394.27394.2724.0FalseNoneNoneFalseNoneFalse9462.480
3922252151273NoneBOQ412Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete,As per direction of engineer in charge Concealed work including cutting chases and good the walls etc. 20 mm dia pipe nominal OD pipes Second FloorRmtr398.18398.1824.0FalseNoneNoneFalseNoneFalse9556.320
3922253151273NoneBOQ413Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20mm nominal bore First FloorEach326.65326.656.0FalseNoneNoneFalseNoneFalse1959.90
3922254151273NoneBOQ414Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20mm nominal bore Second FloorEach9.619.615.0FalseNoneNoneFalseNoneFalse48.050
3922255151273NoneBOQ415Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete As per direction of engineer in charge (external work) 20 mm dia pipe nominal OD pipes First FloorRmtr225.75225.7512.0FalseNoneNoneFalseNoneFalse2709.00
3922256151273NoneBOQ416Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete As per direction of engineer in charge (external work) 20 mm dia pipe nominal OD pipes Second FloorRmtr227.98227.9824.0FalseNoneNoneFalseNoneFalse5471.520
3922257151273NoneBOQ417Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete As per direction of engineer in charge (external work 25 mm dia pipe nominal OD pipes First FloorRmtr307.93307.9310.0FalseNoneNoneFalseNoneFalse3079.30
3922258151273NoneBOQ418Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete As per direction of engineer in charge (external work 25 mm dia pipe nominal OD pipes Second FloorRmtr310.98310.9824.0FalseNoneNoneFalseNoneFalse7463.520
3922259151273NoneBOQ419Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete As per direction of engineer in charge (external work 32 mm dia pipe nominal OD pipes First FloorRmtr386.99386.9930.0FalseNoneNoneFalseNoneFalse11609.70
3922260151273NoneBOQ420Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete As per direction of engineer in charge (external work 32 mm dia pipe nominal OD pipes Second FloorRmtr390.82390.8256.0FalseNoneNoneFalseNoneFalse21885.920
3922261151273NoneBOQ421Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete As per direction of engineer in charge (external work 40 mm dia pipe nominal OD pipesRmtr496.22496.2250.0FalseNoneNoneFalseNoneFalse24811.00
3922262151273NoneBOQ422Providing and fixing chlorinated poly vinyl chloride ( CPVC) pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete As per direction of engineer in charge (external work 50 mm dia pipe nominal OD pipesRmtr757.48757.4840.0FalseNoneNoneFalseNoneFalse30299.20
3922263151273NoneBOQ423Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 20mm nominal boreEach329.89329.894.0FalseNoneNoneFalseNoneFalse1319.560
3922264151273NoneBOQ424Providing and fixing Brass full way valve gate with C.I wheel of approved quality (screwed end) : 25mm nominal boreEach576.78576.784.0FalseNoneNoneFalseNoneFalse2307.120
3922265151273NoneBOQ425Providing and fixing Brass full way valve gate with C.I wheel of approved quality (screwed end) : 32mm nominal boreEach628.26628.264.0FalseNoneNoneFalseNoneFalse2513.040
3922266151273NoneBOQ426Providing and fixing Brass full way valve gate with C.I wheel of approved quality (screwed end) : 40mm nominal boreEach737.52737.524.0FalseNoneNoneFalseNoneFalse2950.080
3922267151273NoneBOQ427Providing and fixing Brass full way valve gate with C.I wheel of approved quality (screwed end) : 50mm nominal boreEach898.26898.263.0FalseNoneNoneFalseNoneFalse2694.780
3922268151273NoneBOQ428Providing and placing on terrace, polyethylene water storage tanks As per IS 12701 Marked with cover and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes But with out fittings and the base support for the tankLtr9.469.464000.0FalseNoneNoneFalseNoneFalse37840.00
3922269151273NoneBOQ429Supplying & fixing suction Y'/ pot stainer with MS flange of suitable length fabricated from 16 gauge brass sheet with 3mm slots 50 mm diaNos4344.04344.02.0FalseNoneNoneFalseNoneFalse8688.00
3922270151273NoneBOQ430Supplying , fixing, testing and commissioning of PVC welded rain water head / khurras dome type grating with puddle flange to fix head in RCC slab specially fabricated from minimum 4mm thick PVC sheet, including removable heavy duty PVC grating of 50 x 3 mm thick PVC flats (Round or Square) as per approved design The quoted rate shall include for necessary grouting the khurras base with approved sealant complete all as shown in the drawing and as specified. 150 x 150mm PVC GratingNos830.0830.06.0FalseNoneNoneFalseNoneFalse4980.00
3922271151273NoneBOQ431Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excavation etc complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc for: PVC pipes 75mm dia. 6 kg/sqcm & class 3 First FloorRmtr228.87228.8754.0FalseNoneNoneFalseNoneFalse12358.980
3922272151273NoneBOQ432Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excavation etc complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc for: PVC pipes 75mm dia. 6 kg/sqcm & class 3 Second FloorRmtr70.3970.3980.0FalseNoneNoneFalseNoneFalse5631.20
3922273151273NoneBOQ433Supply and delivery at site special moulded variety 75 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments First FloorNos69.769.75.0FalseNoneNoneFalseNoneFalse348.50
3922274151273NoneBOQ434Supply and delivery at site special moulded variety 75 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments Second FloorNos73.5473.545.0FalseNoneNoneFalseNoneFalse367.70
3922275151273NoneBOQ435Supply and delivery at site special moulded variety 75 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments First FloorNos199.74199.745.0FalseNoneNoneFalseNoneFalse998.70
3922276151273NoneBOQ436Supply and delivery at site special moulded variety 75 mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments Second FloorNos201.71201.715.0FalseNoneNoneFalseNoneFalse1008.550
3922277151273NoneBOQ437Supply and delivery at site special moulded variety 75 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments First FloorNos121.71121.715.0FalseNoneNoneFalseNoneFalse608.550
3922278151273NoneBOQ438Supply and delivery at site special moulded variety 75 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments Second FloorNos122.92122.925.0FalseNoneNoneFalseNoneFalse614.60
3922279151273NoneBOQ439Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excavation etc complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc for: PVC pipes 110mm dia. 6 kg/sqcm & class 3 First FloorRmtr427.56427.5650.0FalseNoneNoneFalseNoneFalse21378.00
3922280151273NoneBOQ440Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excavation etc complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc for: PVC pipes 110mm dia. 6 kg/sqcm & class 3 Second FloorRmtr431.8431.848.0FalseNoneNoneFalseNoneFalse20726.40
3922281151273NoneBOQ441Supply and delivery at site special moulded variety 110 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments. 110mm dia PVC couplers First FloorRmtr177.89177.895.0FalseNoneNoneFalseNoneFalse889.450
3922282151273NoneBOQ442Supply and delivery at site special moulded variety 110 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments. 110mm dia PVC couplers Second FloorRmtr179.65179.655.0FalseNoneNoneFalseNoneFalse898.250
3922283151273NoneBOQ443Supply and delivery at site special moulded variety 110mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments First FloorNos314.17314.175.0FalseNoneNoneFalseNoneFalse1570.850
3922284151273NoneBOQ444Supply and delivery at site special moulded variety 110mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments Second FloorNos317.28317.285.0FalseNoneNoneFalseNoneFalse1586.40
3922285151273NoneBOQ445Supply and delivery at site special moulded variety 110 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments First FloorNos261.12261.125.0FalseNoneNoneFalseNoneFalse1305.60
3922286151273NoneBOQ446Supply and delivery at site special moulded variety 110 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments Second FloorNos261.12261.125.0FalseNoneNoneFalseNoneFalse1305.60
3922287151273NoneBOQ447Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms with soft gravel or selected earth available from the excavation etc complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc for: 160mm dia PVC pipeRmtr636.54636.5420.0FalseNoneNoneFalseNoneFalse12730.80
3922288151273NoneBOQ448Supply and delivery at site special moulded variety 160 mm dia PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendmentsNos345.05345.052.0FalseNoneNoneFalseNoneFalse690.10
3922289151273NoneBOQ449Supply and delivery at site special moulded variety 160mm dia PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendmentsNos485.13485.132.0FalseNoneNoneFalseNoneFalse970.260
3922290151273NoneBOQ450Supply and delivery at site special moulded variety 160 mm dia PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendmentsNos479.98479.982.0FalseNoneNoneFalseNoneFalse959.960
3922291151273NoneBOQ451Providing And fixing Square mouth stone ware gully trap SP-1 Complete With CI Grating Brick Masonry Chamber 100x100mm Size P trap With Non modular common burnt bricks of designation 3.5, with water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 KG, and frame to be not less than 2.70Kg as per the standard designEach2607.962607.962.0FalseNoneNoneFalseNoneFalse5215.920
3922292151273NoneBOQ452Constructing brick masonry chamber for underground C.I inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C top slab with 1:1.5:3 mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc complete as per standard design: Inside dimensions 455x610 mm and 45 cm deep for single pipe line : With common burnt clay (non modular) bricks of class designation 3.5Nos5811.265811.261.0FalseNoneNoneFalseNoneFalse5811.260
3922293151273NoneBOQ453Providing and constructing “WIRE CUT BRICK MACHINEHOLE CHAMBERS” using Portland/Pozzolana cement, conical in shape at top, with CC 1:3:6 foundation using 40mm and down size graded metal of approved quality and with an offset of 0.15M alround the chamber Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm Slope inside to be 1:6 in the concrete towards central drain and finished smooth Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size Supplying and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4 Supplying and fixing footsteps made of 12mm dia steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910) The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc as per the drawing etc as per technical specifications and for the following diameters and depth etc for 1.2mm diaCirc B M.H:Nos35729.6735729.671.0FalseNoneNoneFalseNoneFalse35729.670
3922294151273NoneBOQ454Earth work in surface excavation for stripping, seating of bund, Road way by manual means for lowering & levelling the ground for all works other than foundation & depth in Ordinary rock and soft rock upto 300mm depth as per drawing and technical specifications, including setting out, barricading, caution lights, including dressing of excavated surfaces,disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.Cum592.25592.2518.3FalseNoneNoneFalseNoneFalse10838.1750
3922295151273NoneBOQ455DOMESTIC WATER TRANSFAR PUMP Supplying, installing, testing and commissioning of submersible / Mono blockelectrical driven pump 1set (1 working & standby) domestic water pumps for pumping domestic water from U.G sump to over head water tank, with all necessary arrangements to operate on 3HP 50 HZ, 440V AC supply fitted on a common base frame accessories to lift the pump during maintenance , necessary power connections, the supplier shall include the control panel and wiring from TPN switch to control panel and wiring upto pumps, the control panel comprising of O/L relays, single phase preventor,separate overload trip and relayset, ON/OFF/TRIP indicating lamps,start/stop push buttons, With liquid level controlers, etc. complete as complete Duty of the Pump 4 cum per hour at 20 TO 25 m head Make : Kirloskar/ suguna/texmo/CRI two set industrial type electronic automatic liquid level controllers, with stainless steel probes / sensors.Nos24000.024000.02.0FalseNoneNoneFalseNoneFalse48000.00
3922296151273NoneBOQ456Providing and fixing gun metal non- return valve of approved quality (screwed end) 32 mm nominal boreNos952.75952.751.0FalseNoneNoneFalseNoneFalse952.750
3922297151273NoneBOQ457Providing and fixing gun metal non- return valve of approved quality (screwed end) 40 mm nominal boreEach1274.01274.01.0FalseNoneNoneFalseNoneFalse1274.00
3922298151273NoneBOQ458Construction of brick masonry catch basin chamber chambers of internal clear dimension as mentioned below by using first class table moulded modular bricks 230 mm thick wall in cement mortor joints in 1:4, over CC 1:4:8 bed 150 mm thick including Supplying precast RCC perforated top slab in 1:2:4 Mix (1 cement: 2 coarse coarse sand: 8 graded stone aggregate), with angle iron frame, inside plastering15mm thick with CM 1:3 (1 cement::3 fine sand) finished very smooth with floating coat of neat cement & making benching and channelling in cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 gradedstone aggregate) neatly finished complete as per standard design and as per drawing and specifications.Inside size of 600 x 600mm & depth not exceeding 600 x 600mm including Supplying 450 x 450mm RCC cover with MS L angle frameNos6920.46920.48.0FalseNoneNoneFalseNoneFalse55363.20
3922299151273NoneBOQ459Construction of percolation well / rain water harvest pit of 2 m dia and 3m deep with precast RCC rings, coveringthe top with RCC slab including supply and fixing 600 x 600 RCC MH cover CI / MS rungs etc The quoted rate shall include earth work excavation, back filling, removing excess earth and making good the floor The percolation well harvest pit shall be constructed as per the detail drawings and specification shall consists of: Allernate layers of brick bats, activated charcoal, gravel, pebbles and toped with fine sand for good infiltration 3 Nos bore holes of 160 mm dia from the bottom of percolation pit for a depth of 6m, drilled by using auger manually.Bore hole to be filled with medium sized pebbles to provide mechanical strength to the holes and enhance infiltration. Rate quoted shall be inclusive of earth work excavation, back filling, removing of excess earth as per the instructions of engineer - in charge.Nos27883.027883.02.0FalseNoneNoneFalseNoneFalse55766.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17254537460000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17254537460000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17254537460000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17254537460000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17254537460000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17254537680000NoneNoneELIGIBILITYThe rates quoted shall includes provision for payment towards Employees welfare cess as per prevailing GOK Act.None
17254537810000NoneNoneELIGIBILITYThe Contractor should quote the item wise rates Excluding GST.None
17254537940001NoneNoneELIGIBILITYThe contractor shall quote item wise rates in the tender and the same shall holds good till the works are completed. The rates should include provision for payment of Royalty or any other such taxes due to the Corporation/Government notified by the Government time to time other than GST. The rates quoted should be inclusive of all lead and lift for materials etc.None
17254538060000NoneNoneELIGIBILITYAll other terms and conditions as per NIT and KW4None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneThe bidders shall upload the work done certificate for having executed One building work of value not less than Rs. 106.00 lakhs and completed satisfactorily as a prime contractor within stipulated time period in the past 5 years (i.e., F/Y 2019-20 to 2023-24). Work done certificate shall be duly signed by the officer not below the rank of Executive Engineer or equivalent.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneThe bidders shall upload a valid registered KPWD Civil contractor Licence of Class II and above.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneThe bidders shall achieved turnover for an amount not less than Rs.424.00 lakhs achieved in any two financial years in the past 5 years (i.e. F/Y 2019-20 to 2023-24) (in all classes of civil engineering construction works only). The Turnover certificate along with Balance sheet and P & L statement of past 5 years for the Civil Engineering works only (i.e. F/Y 2019-20 to 2023-24) issued from a Registered Chartered Accountant (Registered Chartered Accountant PIN and UDIN number must be mentioned failing which bid will considered Non-Responsive) should be uploaded.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Annual Turnover Certificate Along with P&L statements of past 5 years as per NIT and KW4 Workdone certificate as per NIT and KW4
NoneNoneNoneNoneThe bidders shall upload the work done certificate for minimum quantities of work executed in any one year, for following quantities (In a continuous period of 12 months from April to March) in the last 5 years (i.e. F/Y 2019-20 to 2023-24) the certificate shall be issued by the officer not below the rank of Executive Engineer or equivalent. a.PCC/RCC -275.00 Cum b.Burnt brick masonry/Solid block masonry -168.00Cum / 730.00 Sqm c.TMT steel reinforcement- 28.00 Tonnes d.Vitrified / Ceramic / Granite flooring -605.00 SqmOthersMinimum Quantities Certificate as per NIT and KW4
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Minimum Quantities Certificate as per NIT and KW4
NoneNoneNoneNoneThe bidder/tenderer or his identified Sub contractor should upload required valid electrical licence along with consent / undertaking letter for executing building electrification works and should have executed similar electrical works totalling for Rs.16.00 lakhs in any one year in the last 5 years, (i.e. F/Y 2019-20 to 2023-24) signed by the officer not below the rank of Executive Engineer or equivalent for Electrical works.OthersElectrical licence, consent letter and Electrical workdone as per NIT and KW4
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Electrical licence, consent letter and Electrical workdone as per NIT and KW4
NoneNoneNoneNoneThe banker certificate pertaining to Liquid Assets for availability of fund requirement for the work not less Rs.63.50 Lakhs issued by Nationalised / Scheduled Bank for the subject work addressed to General Manager (Civil), Corporate office, BESCOM after 31.08.2024 in the enclosed format.OthersBanker certificate As per Enclosed format as per NIT and KW4
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Banker certificate As per Enclosed format as per NIT and KW4
NoneNoneNoneNoneBidders who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The bidder should calculate and upload available tender capacity as per the formula :Assessed available tender capacity : (AXNX1.5 - B) where, A -Maximum value of civil engineering works executed in any one year during the last five years updated to 2024-25 price level taking into account the completed as well as works in progress.N -Number of years prescribed for completion of the works for which tenders are invited.B -Value, at 2024-25 price level, of existing commitments and on-going works to be completed during the next 12 Months.OthersBid Capacity as per NIT and KW4
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Bid Capacity as per NIT and KW4
NoneNoneNoneNoneBidder shall upload the self-declaration affidavit as per the enclosed format on the stamp paper of value not less than Rs. 500/- duly notarizedOthersSelf-declaration affidavit as per the enclosed format on the stamp paper as per NIT and KW4
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Self-declaration affidavit as per the enclosed format on the stamp paper as per NIT and KW4
NoneNoneNoneNoneAll other terms and conditions as per NIT and KW4OthersAll other terms and conditions as per NIT and KW4
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- All other terms and conditions as per NIT and KW4
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
KPWD Registration Certificate as per NIT and KW4TrueTechnical Bid
Annual Turnover Certificate Along with P&L statements of past 5 years as per NIT and KW4TrueTechnical Bid
Workdone certificate as per NIT and KW4TrueTechnical Bid
Minimum Quantities Certificate as per NIT and KW4TrueTechnical Bid
Electrical licence, consent letter and Electrical workdone as per NIT and KW4TrueTechnical Bid
Banker certificate As per Enclosed format as per NIT and KW4TrueTechnical Bid
Bid Capacity as per NIT and KW4TrueTechnical Bid
Self-declaration affidavit as per the enclosed format on the stamp paper as per NIT and KW4TrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1725456733000
version0
createdDateNone
modifiedDateNone
blockNumberFirst floor, Belaku Bhavana, BESCOM Corporate office, K R Circle, Bengaluru
streetNone
cityBengaluru
stateKarnataka
pin560001
tenderRecallDTONone