createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1725453022878
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd483000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose08-10-2024 16:00:00
tenderQueryClose01-10-2024 16:00:00
technicalBidOpen09-10-2024 16:05:00
publishedDate05-09-2024 12:53:04
publishedByPostBESCOM_GM_CIV_BNG
publishedByUserKPE16137 - T G RAMAKRISHNA
bidValidityPeriod90
noOfCalls1
preBidMeetingDate18-09-2024 15:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonT G Ramakrishna
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber8277892569
tenderSupplierListNone
tenderSchedule
createdTs1725453022908
version6
createdDateNone
modifiedDateNone
tenderNumberBESCOM/2024-25/BD/WORK_INDENT203
titleConstruction of Residential quarters Block-I (8 tenaments) for Lineman at BESCOM New colony premises, Chitradurga.
descriptionConstruction of Residential quarters Block-I (8 tenaments) for Lineman at BESCOM New colony premises, Chitradurga.
categoryWORKS
categoryTextWorks
ecv32186700.04
deptNameBangalore Electricity Supply Company Limited
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location3834
locationNameBESCOM Corporate Office Civil Section Bengaluru
provisionalAmount38000000.0
groupOverheadTotal0.0
fileNumberBESCOM/GM/Civil/2024-25/51
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17254530230000NoneNoneBuildingsConstruction of Residential quarters Block-I (8 tenaments) for Lineman at BESCOM New colony premises, Chitradurga.32186700.04
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3921518151263NoneBOQ1Clearing and grubbing road land including uprooting rankvegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. (ii) By Mechanical Means using DozerSqm404.79404.799.0FalseNoneNoneFalseNoneFalse3643.110
3921519151263NoneBOQ2Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring,strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work In all kinds of soil upto 300 mm depthSqm93.7393.73904.0FalseNoneNoneFalseNoneFalse84731.920
3921520151263NoneBOQ3Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. Depth exceeding 1.5m, but not exceeding 3 mCum266.77266.771342.0FalseNoneNoneFalseNoneFalse358005.340
3921521151263NoneBOQ4Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm121.54121.541118.0FalseNoneNoneFalseNoneFalse135881.720
3921522151263NoneBOQ5Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading,grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work.Cum488.22488.22954.0FalseNoneNoneFalseNoneFalse465761.880
3921523151263NoneBOQ6Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth,consolidating Each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum273.98273.98100.0FalseNoneNoneFalseNoneFalse27398.00
3921524151263NoneBOQ7Providing and Filling in foundation with granite / trap broken metal 100mm. and down size, with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift. complete as per specifications. specification.Cum2762.462762.46206.0FalseNoneNoneFalseNoneFalse569066.760
3921525151263NoneBOQ8Providing Size STonnee masonry with hard sTonnee in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum6580.676580.6760.75FalseNoneNoneFalseNoneFalse399775.70250
3921526151263NoneBOQ9Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregatesCum6168.676168.67144.0FalseNoneNoneFalseNoneFalse888288.480
3921527151263NoneBOQ10Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7048.177048.1798.0FalseNoneNoneFalseNoneFalse690720.660
3921528151263NoneBOQ11do columns upto plinth (Including formwork charges).Cum11094.3411094.3421.0FalseNoneNoneFalseNoneFalse232981.140
3921529151263NoneBOQ12do Plinth Beam (Including formwork charges).Cum9789.129789.1231.0FalseNoneNoneFalseNoneFalse303462.720
3921530151263NoneBOQ13Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevantIS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm and down size graded crushed coarse aggregatesCum8792.138792.1347.0FalseNoneNoneFalseNoneFalse413230.110
3921531151263NoneBOQ14Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes finsishing concrete structure in line, all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm and down size graded crushed coarse aggregates do columns Ground Floor (Including formwork charges)Cum11982.0911982.0924.0FalseNoneNoneFalseNoneFalse287570.160
3921532151263NoneBOQ15do columns First Floor (Including formwork charges).Cum12101.9112101.9124.0FalseNoneNoneFalseNoneFalse290445.840
3921533151263NoneBOQ16do columns Second Floor (Including formwork charges).Cum12222.9312222.9324.0FalseNoneNoneFalseNoneFalse293350.320
3921534151263NoneBOQ17do columns Terrace Floor (Including formwork charges).Cum12345.1612345.162.0FalseNoneNoneFalseNoneFalse24690.320
3921535151263NoneBOQ18do beams Ground Floor (Including formwork charges).Cum11277.2611277.2640.5FalseNoneNoneFalseNoneFalse456729.030
3921536151263NoneBOQ19do beams First Floor (Including formwork charges).Cum11390.0411390.0446.0FalseNoneNoneFalseNoneFalse523941.840
3921537151263NoneBOQ20do beams Second Floor (Including formwork charges).Cum11503.9411503.9441.85FalseNoneNoneFalseNoneFalse481439.8890
3921538151263NoneBOQ21do beams Terrace Floor (Including formwork charges).Cum11618.9811618.982.0FalseNoneNoneFalseNoneFalse23237.960
3921539151263NoneBOQ22do slab Ground Floor (Including formwork charges).Cum10572.4410572.4445.0FalseNoneNoneFalseNoneFalse475759.80
3921540151263NoneBOQ23do slab First Floor (Including formwork charges).Cum10678.1610678.1673.0FalseNoneNoneFalseNoneFalse779505.680
3921541151263NoneBOQ24do slab Second Floor (Including formwork charges).Cum10784.9410784.9446.0FalseNoneNoneFalseNoneFalse496107.240
3921542151263NoneBOQ25do slab Terrace Floor (Including formwork charges).Cum10892.7910892.793.0FalseNoneNoneFalseNoneFalse32678.370
3921543151263NoneBOQ26Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.Do-Foundation workTonne92140.7192140.7120.0FalseNoneNoneFalseNoneFalse1842814.20
3921544151263NoneBOQ27Do-TMT reinforcement Ground FloorTonne92140.7192140.7115.0FalseNoneNoneFalseNoneFalse1382110.650
3921545151263NoneBOQ28Do-TMT reinforcement First FloorTonne93062.1293062.1215.0FalseNoneNoneFalseNoneFalse1395931.80
3921546151263NoneBOQ29Do-TMT reinforcement Second FloorTonne93992.7493992.7415.0FalseNoneNoneFalseNoneFalse1409891.10
3921547151263NoneBOQ30Do-TMT reinforcement Terrace FloorTonne94932.6794932.671.0FalseNoneNoneFalseNoneFalse94932.670
3921548151263NoneBOQ31Providing brickwork with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement: 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer in charge of work etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work. do-Ground FloorCum8467.638467.6321.0FalseNoneNoneFalseNoneFalse177820.230
3921549151263NoneBOQ32do- First Floor Brick workCum8552.318552.31159.0FalseNoneNoneFalseNoneFalse1359817.290
3921550151263NoneBOQ33do-Second Floor Brick workCum8637.838637.83159.0FalseNoneNoneFalseNoneFalse1373414.970
3921551151263NoneBOQ34do-Terrace Floor Brick workCum8724.218724.2156.0FalseNoneNoneFalseNoneFalse488555.760
3921552151263NoneBOQ35Providing 12 mm cement plaster (ceiling surface) with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.do-Ground FloorSqm262.65262.65400.0FalseNoneNoneFalseNoneFalse105060.00
3921553151263NoneBOQ36do- First Floor ceiling PlasteringSqm265.28265.28380.0FalseNoneNoneFalseNoneFalse100806.40
3921554151263NoneBOQ37do-Second Floor ceiling PlasteringSqm267.93267.93380.0FalseNoneNoneFalseNoneFalse101813.40
3921555151263NoneBOQ38do-Terrace Floor ceiling PlasteringSqm270.61270.6111.0FalseNoneNoneFalseNoneFalse2976.710
3921556151263NoneBOQ39Providing 20 mm cement plaster (internal surface) of mix :1:6 (1 cement: 6 fine sand) to brick/sTonnee masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. do-Ground FloorSqm342.99342.99381.0FalseNoneNoneFalseNoneFalse130679.190
3921557151263NoneBOQ40do- First Floor Internal surface PlasteringSqm346.42346.421252.0FalseNoneNoneFalseNoneFalse433717.840
3921558151263NoneBOQ41do-Second Floor Internal surface PlasteringSqm349.88349.881252.0FalseNoneNoneFalseNoneFalse438049.760
3921559151263NoneBOQ42do-Terrace Floor Internal surface PlasteringSqm353.38353.3840.0FalseNoneNoneFalseNoneFalse14135.20
3921560151263NoneBOQ43Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. do-Ground FloorSqm103.0103.0381.0FalseNoneNoneFalseNoneFalse39243.00
3921561151263NoneBOQ44do- First Floor puttySqm104.03104.031252.0FalseNoneNoneFalseNoneFalse130245.560
3921562151263NoneBOQ45do-Second Floor puttySqm105.07105.071252.0FalseNoneNoneFalseNoneFalse131547.640
3921563151263NoneBOQ46do-Terrace Floor puttySqm106.12106.1240.0FalseNoneNoneFalseNoneFalse4244.80
3921564151263NoneBOQ47Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 Sqm over and including one coat of Special primer applied @ 0.75 L/10 Sqm with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life)do-Ground FloorSqm162.74162.74381.0FalseNoneNoneFalseNoneFalse62003.940
3921565151263NoneBOQ48do- First Floor interior paintSqm164.37164.371252.0FalseNoneNoneFalseNoneFalse205791.240
3921566151263NoneBOQ49do-Second Floor interior paintSqm166.01166.011252.0FalseNoneNoneFalseNoneFalse207844.520
3921567151263NoneBOQ50do-Terrace Floor interior paintSqm167.67167.6740.0FalseNoneNoneFalseNoneFalse6706.80
3921568151263NoneBOQ51Providing 20 mm cement plaster of mix :1:4 (External surface) (1 cement: 4 fine sand) to brick/sTonnee masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge..do-Ground FloorSqm364.62364.62312.0FalseNoneNoneFalseNoneFalse113761.440
3921569151263NoneBOQ52do- First Floor 20 mm cement plaster of mix :1:4 (External surface)Sqm368.27368.27612.0FalseNoneNoneFalseNoneFalse225381.240
3921570151263NoneBOQ53do-Second Floor 20 mm cement plaster of mix :1:4 (External surface)Sqm371.95371.95612.0FalseNoneNoneFalseNoneFalse227633.40
3921571151263NoneBOQ54do-Terrace Floor 20 mm cement plaster of mix :1:4 (External surface)Sqm375.67375.67536.0FalseNoneNoneFalseNoneFalse201359.120
3921572151263NoneBOQ55Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. do-Ground FloorSqm179.22179.22312.0FalseNoneNoneFalseNoneFalse55916.640
3921573151263NoneBOQ56do- First Floor exterior paintingSqm181.01181.01612.0FalseNoneNoneFalseNoneFalse110778.120
3921574151263NoneBOQ57do-Second Floor exterior paintingSqm182.82182.82612.0FalseNoneNoneFalseNoneFalse111885.840
3921575151263NoneBOQ58do-Terrace Floor exterior paintingSqm184.65184.65536.0FalseNoneNoneFalseNoneFalse98972.40
3921576151263NoneBOQ59Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.. Size of Tile 600x600 mm do-First FloorSqm1384.321384.32305.0FalseNoneNoneFalseNoneFalse422217.60
3921577151263NoneBOQ60do-Second Floor vitrified floor Size of Tile 600x600 mmSqm1398.161398.16302.0FalseNoneNoneFalseNoneFalse422244.320
3921578151263NoneBOQ61Providing and laying Black Lapotra Granite sTonnee flooring in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18mm thick sTonnee slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. do-do- First FloorSqm2686.062686.0622.0FalseNoneNoneFalseNoneFalse59093.320
3921579151263NoneBOQ62do- Second Floor granite flooringSqm2712.922712.9222.0FalseNoneNoneFalseNoneFalse59684.240
3921580151263NoneBOQ63Providing and laying flooring and steps fine machine polished granite sTonnee slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. do-Ground FloorSqm5487.845487.8419.0FalseNoneNoneFalseNoneFalse104268.960
3921581151263NoneBOQ64do- First Floor stairs flooringSqm5542.725542.7219.0FalseNoneNoneFalseNoneFalse105311.680
3921582151263NoneBOQ65do- Second Floor stairs flooringSqm5598.155598.1519.0FalseNoneNoneFalseNoneFalse106364.850
3921583151263NoneBOQ66Providing full nosing for 20mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM of equipment etc., complete as per specification.m309.0309.0250.0FalseNoneNoneFalseNoneFalse77250.00
3921584151263NoneBOQ67Providing and fixing 1st quality ceramic glazed wall tiles conformingto IS: 15622 (thickness to be specified by the manufacturer), ofapproved make, in all colours, shades except burgundy, bottle green,black of any size as approved by Engineer- in-Charge, in skirting,risers of steps and dados, over 12 mm thick bed of cement mortar 1:3(1 cement : 3 coarse sand) and jointing with grey cement slurry @3.3kg per m2, including pointing in white cement mixed with pigmentof matching shade complete.do-First FloorSqm1150.571150.57199.0FalseNoneNoneFalseNoneFalse228963.430
3921585151263NoneBOQ68do- Second Floor ceramic glazed wall tilesSqm1162.081162.08199.0FalseNoneNoneFalseNoneFalse231253.920
3921586151263NoneBOQ69Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. do-First floorSqm924.83924.8335.0FalseNoneNoneFalseNoneFalse32369.050
3921587151263NoneBOQ70do- Second Floor Ceramic glazed floor tileSqm934.07934.0735.0FalseNoneNoneFalseNoneFalse32692.450
3921588151263NoneBOQ71Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs,laid to slope compacting, including cost of materials, labour, curing complete as per specificationsCum2077.512077.517.0FalseNoneNoneFalseNoneFalse14542.570
3921589151263NoneBOQ72Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded sTonnee aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded sTonnee aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge.Sqm824.0824.0400.0FalseNoneNoneFalseNoneFalse329600.00
3921590151263NoneBOQ73Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge etc., complete with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc.,Sqm841.51841.51558.0FalseNoneNoneFalseNoneFalse469562.580
3921591151263NoneBOQ74Providing and laying water proofing treatment to the Water tanks & Liquid Retaining structures with two component acrylic polymer modified cementitious waterproofing membrane with minimum elongation of 50% applied @ 1.5 kg/m2 for internal side waterproofing in two layers with waiting period of 4-6 hrs per layer and food grade epoxy coating in two coats certified by CFTRI Mysuru, including surface preparation completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm522.21522.2150.0FalseNoneNoneFalseNoneFalse26110.50
3921592151263NoneBOQ75Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.Cum142216.22142216.221.5FalseNoneNoneFalseNoneFalse213324.330
3921593151263NoneBOQ76Providing and fixing in position fully panelled Honne wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications.Sqm6334.56334.517.0FalseNoneNoneFalseNoneFalse107686.50
3921594151263NoneBOQ77Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets ( core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 ( part-I) 1991. from manufacturer complete as per spcification.--do- 30 mm thick one side teak and one side commercialSqm3597.793597.7967.0FalseNoneNoneFalseNoneFalse241051.930
3921595151263NoneBOQ78Polishing in high gloss/matt finish melamine clear polish on wood work in required color/wooden shade texture with following process in the sequence as detailed below: 1. The surface to be polished is rubbed with sand paper 80/120 no. and then with sand paper of 160/180 nos.2. Applying two coats of sealer with spray gun and allowing sufficientdrying time for 1st coat and 2nd coat is allowed to dry for 8 to 12 hrs.3. On drying of sealer coat, wet rubbing with emery cloth of finergrading with ample water to remove excess sealer layer and make the surface further smooth after this wet rubbing, then surface is applied with special grade melamine fillers to fill all the small and big holes/grooves etc. Filler coat to be allowed to dry for 4 to 6 hrs on which again a light wet rubbing is done this surface is further allowed to dry for 12 hrs. 4. On this, 1st coat of melamine polish is applied with spray gun using melamine clear polish and melamine thinner in required proportion.Sqm697.31697.31134.0FalseNoneNoneFalseNoneFalse93439.540
3921596151263NoneBOQ79Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1083.561083.5632.0FalseNoneNoneFalseNoneFalse34673.920
3921597151263NoneBOQ80Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.Nos123.6123.632.0FalseNoneNoneFalseNoneFalse3955.20
3921598151263NoneBOQ81Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNos244.11244.1164.0FalseNoneNoneFalseNoneFalse15623.040
3921599151263NoneBOQ82Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :250x10mmNos448.05448.0564.0FalseNoneNoneFalseNoneFalse28675.20
3921600151263NoneBOQ83Providing and fixing bright finished brass butt hinges with necessary screws etc. complete 125x85x5.5 mm (heavy type)Nos283.25283.25128.0FalseNoneNoneFalseNoneFalse36256.00
3921601151263NoneBOQ84Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge SS Aldrop 16mm dia, 200mmNos309.0309.010.0FalseNoneNoneFalseNoneFalse3090.00
3921602151263NoneBOQ85Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications etc., with all leads and lifts cost and conveyance of all materials, cost of labour, curing, hire charges of machinery equipment, transportation charges, loading and unloading charges and all other incidental charges etc., complete as per standard technical detailed specification and directions of the Engineer in charge of the work.Nos1046.481046.4832.0FalseNoneNoneFalseNoneFalse33487.360
3921603151263NoneBOQ86Providing & fixing Factory made single extruded Wood Polymer Composite (WPC) solid door/window, clerestory windows & frames /chowkhat of frame size 65 x 100mmRmtr723.06723.0694.0FalseNoneNoneFalseNoneFalse67967.640
3921604151263NoneBOQ87Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately) 35 mm thicknessSqm4162.234162.2320.0FalseNoneNoneFalseNoneFalse83244.60
3921605151263NoneBOQ88Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having a overall size of 60mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm X 58mm with GI reinforcement of 1mm for the frame and 1.5 mm for the sash. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with touch lock. Wall thickness of frame & sash shall be of 2-2.5 mm. Maximum possible size 1819mm x 1819mm (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm5551.75551.758.0FalseNoneNoneFalseNoneFalse321998.60
3921606151263NoneBOQ89Providing& fixing of Openable window made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 75mm and GI reinforcement of 1.5mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 5mm plain float glass, Standard hardware with friction hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm.Maximum possible size 900mm x 1819mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be madeSqm6243.866243.866.0FalseNoneNoneFalseNoneFalse37463.160
3921607151263NoneBOQ90Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kgs188.49188.491283.0FalseNoneNoneFalseNoneFalse241832.670
3921608151263NoneBOQ91Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm172.01172.0165.0FalseNoneNoneFalseNoneFalse11180.650
3921609151263NoneBOQ92Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. etc., complete as per specification with all lead and lift and as per directions of the Engineer-in-charge of the work.Kgs581.95581.95606.0FalseNoneNoneFalseNoneFalse352661.70
3921610151263NoneBOQ93Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg151.41151.41700.0FalseNoneNoneFalseNoneFalse105987.00
3921611151263NoneBOQ94Providing and fixing 6mm Clear/opal white/solar bronze/blue/green tinted Multi wall poly carbonate sheet for Tubular structure. The work including cost of all materials, labour charges, and hire charges of machinery for cutting, welding, grinding and erection equipments, with all lead and lifts, transportation, loading and unloading and all other incidental charges etc. complete as per specification and directions of the engineer in charge of the work.Sqm3218.753218.759.0FalseNoneNoneFalseNoneFalse28968.750
3921612151263NoneBOQ95Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm8524.288524.285.0FalseNoneNoneFalseNoneFalse42621.40
3921613151263NoneBOQ96Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm4612.344612.3424.0FalseNoneNoneFalseNoneFalse110696.160
3921614151263NoneBOQ97Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc complete 2.00 HP/1.5KW, 12 STGEach18146.5418146.542.0FalseNoneNoneFalseNoneFalse36293.080
3921615151263NoneBOQ98Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank.Ltr9.279.274000.0FalseNoneNoneFalseNoneFalse37080.00
3921616151263NoneBOQ99Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 110mm dia., 6 kg/sqcm & class 3Rmtr423.33423.33110.0FalseNoneNoneFalseNoneFalse46566.30
3921617151263NoneBOQ100PVC pipes 75mm dia., 6 kg/sqcm & class 3Rmtr226.6226.6230.0FalseNoneNoneFalseNoneFalse52118.00
3921618151263NoneBOQ101Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 40 mm nominal dia PipesRmtr552.08552.0880.0FalseNoneNoneFalseNoneFalse44166.40
3921619151263NoneBOQ10232 mm nominal dia PipesRmtr412.0412.080.0FalseNoneNoneFalseNoneFalse32960.00
3921620151263NoneBOQ10325 mm nominal dia PipesRmtr327.54327.54360.0FalseNoneNoneFalseNoneFalse117914.40
3921621151263NoneBOQ10420 mm nominal dia PipesRmtr249.26249.2680.0FalseNoneNoneFalseNoneFalse19940.80
3921622151263NoneBOQ105Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :25 mm nominal boreNos565.47565.475.0FalseNoneNoneFalseNoneFalse2827.350
3921623151263NoneBOQ10635 mm nominal boreNos615.94615.945.0FalseNoneNoneFalseNoneFalse3079.70
3921624151263NoneBOQ107Providing and fixing gun metal non- return valve of approved quality (screwed end) : 25 mm nominal boreNos638.6638.610.0FalseNoneNoneFalseNoneFalse6386.00
3921625151263NoneBOQ108Supplying of special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments to walk site etc. complete.140mm dia PVC couplersNos229.95229.9525.0FalseNoneNoneFalseNoneFalse5748.750
3921626151263NoneBOQ109110 mm dia PVC couplersNos179.55179.5525.0FalseNoneNoneFalseNoneFalse4488.750
3921627151263NoneBOQ11075 mm dia PVC couplersNos70.3570.3525.0FalseNoneNoneFalseNoneFalse1758.750
3921628151263NoneBOQ111Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 140 mm dia PVC ElbowsNos374.85374.8525.0FalseNoneNoneFalseNoneFalse9371.250
3921629151263NoneBOQ112110 mm dia PVC ElbowsNos317.1317.125.0FalseNoneNoneFalseNoneFalse7927.50
3921630151263NoneBOQ11375 mm dia PVC ElbowsNos201.6201.625.0FalseNoneNoneFalseNoneFalse5040.00
3921631151263NoneBOQ114Supply and delivery at site special moulded variety PVC tee as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 140 mm dia PVC TeeNos375.9375.925.0FalseNoneNoneFalseNoneFalse9397.50
3921632151263NoneBOQ115110 mm dia PVC TeeNos263.55263.5525.0FalseNoneNoneFalseNoneFalse6588.750
3921633151263NoneBOQ11675 mm dia PVC TeeNos122.85122.8525.0FalseNoneNoneFalseNoneFalse3071.250
3921634151263NoneBOQ117Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 140 mm dia PVC BENDNos626.85626.8525.0FalseNoneNoneFalseNoneFalse15671.250
3921635151263NoneBOQ118110 mm dia PVC BENDNos516.6516.625.0FalseNoneNoneFalseNoneFalse12915.00
3921636151263NoneBOQ11975 mm dia PVC BENDNos257.25257.2525.0FalseNoneNoneFalseNoneFalse6431.250
3921637151263NoneBOQ120Supply and delivery at site special moulded variety PVC reducer as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments 140 mm dia PVC BENDNos336.0336.025.0FalseNoneNoneFalseNoneFalse8400.00
3921638151263NoneBOQ121110 mm dia PVC BENDNos274.05274.0525.0FalseNoneNoneFalseNoneFalse6851.250
3921639151263NoneBOQ12275 mm dia PVC BENDNos109.2109.225.0FalseNoneNoneFalseNoneFalse2730.00
3921640151263NoneBOQ123Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :-W.C. pan with ISI marked white solid plastic seat and lidEach6156.316156.318.0FalseNoneNoneFalseNoneFalse49250.480
3921641151263NoneBOQ124Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm withintegral type foot restsEach5030.525030.528.0FalseNoneNoneFalseNoneFalse40244.160
3921642151263NoneBOQ125Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixerEach4244.634244.6316.0FalseNoneNoneFalseNoneFalse67914.080
3921643151263NoneBOQ126Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge.Each834.3834.316.0FalseNoneNoneFalseNoneFalse13348.80
3921644151263NoneBOQ127Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.Each5728.865728.868.0FalseNoneNoneFalseNoneFalse45830.880
3921645151263NoneBOQ128Providing and fixing 100 mm sand cast Iron grating for gully trap.Each48.4148.4120.0FalseNoneNoneFalseNoneFalse968.20
3921646151263NoneBOQ129Providing and fixing brass bib cock of approved quality :20 mm nominal boreEach314.15314.1532.0FalseNoneNoneFalseNoneFalse10052.80
3921647151263NoneBOQ130Providing and fixing brass stop cock of approved quality :20 mm nominal boreEach314.15314.1516.0FalseNoneNoneFalseNoneFalse5026.40
3921648151263NoneBOQ131600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.Each510.88510.8816.0FalseNoneNoneFalseNoneFalse8174.080
3921649151263NoneBOQ132Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Each1256.61256.616.0FalseNoneNoneFalseNoneFalse20105.60
3921650151263NoneBOQ133Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and coverEach4934.734934.735.0FalseNoneNoneFalseNoneFalse24673.650
3921651151263NoneBOQ134Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.Each5617.625617.625.0FalseNoneNoneFalseNoneFalse28088.10
3921652151263NoneBOQ135Providing and fixing kitchen sink including making all connections including cost of fittings with White glazed fire clay sink of size 600x450x250 mmEach2023.952023.958.0FalseNoneNoneFalseNoneFalse16191.60
3921653151263NoneBOQ136Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeEach220.0220.010.0FalseNoneNoneFalseNoneFalse2200.00
3921654151263NoneBOQ137ELECTRICAL WORK:Concealed Conduit System -Supplying heavy gauge PVC conduit pipe 19/20 mm dia 2 mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary-19/20mm dia 2mm thick.m66.066.0600.0FalseNoneNoneFalseNoneFalse39600.00
3921655151263NoneBOQ138Concealed Conduit System -Supplying heavy gauge PVC conduit pipe 25 mm dia 2 mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary- 25mm dia 2mm thickm78.078.0880.0FalseNoneNoneFalseNoneFalse68640.00
3921656151263NoneBOQ139Supplying heavy gauge PVC Conduit Pipe 19/20mm dia 2 mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary-19/20mm dia 2mm thick.m68.068.0400.0FalseNoneNoneFalseNoneFalse27200.00
3921657151263NoneBOQ140Supplying heavy gauge PVC Conduit Pipe 25mm dia 2 mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary-25mm dia 2mm thick -25mm dia 2mm thick.m79.079.0520.0FalseNoneNoneFalseNoneFalse41080.00
3921658151263NoneBOQ141Supplying and fixing of PVC casing and capping on the wall or ceilling using necessary materials like bends,junction box , elbows,screws at an interval of 300mm etc as required. 20mm sizem28.028.080.0FalseNoneNoneFalseNoneFalse2240.00
3921659151263NoneBOQ142Supplying and fixing of PVC casing and capping on the wall or ceilling using necessary materials like bends,junction box , elbows,screws at an interval of 300mm etc as required. 25mm sizem35.035.080.0FalseNoneNoneFalseNoneFalse2800.00
3921660151263NoneBOQ143Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase& Neutral) & 1x1.0 sqmm (Earth wire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated withsufficient loose length in a wood/PVC round block. complete for Each outlet.-Short point upto 3Mtr from tapping point to out let via switch .Point285.0285.040.0FalseNoneNoneFalseNoneFalse11400.00
3921661151263NoneBOQ144Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase& Neutral) & 1x1.0 sqmm (Earth wire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated withsufficient loose length in a wood/PVC round block. complete for Each outlet.-Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch.Point394.0394.080.0FalseNoneNoneFalseNoneFalse31520.00
3921662151263NoneBOQ145Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase& Neutral) & 1x1.0 sqmm (Earth wire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated withsufficient loose length in a wood/PVC round block. complete for Each outlet.Long point above 6Mtr upto 10Mtr from tapping point to out let via switch.Point570.0570.0162.0FalseNoneNoneFalseNoneFalse92340.00
3921663151263NoneBOQ146supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/sTonnee/c.c wall -3 way .Each159.0159.088.0FalseNoneNoneFalseNoneFalse13992.00
3921664151263NoneBOQ147supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/sTonnee/c.c wall- 4-5 way .Each177.0177.032.0FalseNoneNoneFalseNoneFalse5664.00
3921665151263NoneBOQ148supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/sTonnee/c.c wall- 6way .Each220.0220.022.0FalseNoneNoneFalseNoneFalse4840.00
3921666151263NoneBOQ149supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/sTonnee/c.c wall- 8way .Each261.0261.016.0FalseNoneNoneFalseNoneFalse4176.00
3921667151263NoneBOQ150supplying and flush mounting powder coated /galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/sTonnee/c.c wall- 10-12way.Each319.0319.082.0FalseNoneNoneFalseNoneFalse26158.00
3921668151263NoneBOQ151Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.- 1-3 module .Each161.0161.088.0FalseNoneNoneFalseNoneFalse14168.00
3921669151263NoneBOQ152Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.- 4 module.Each175.0175.032.0FalseNoneNoneFalseNoneFalse5600.00
3921670151263NoneBOQ153Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.- 6 module.Each234.0234.022.0FalseNoneNoneFalseNoneFalse5148.00
3921671151263NoneBOQ154Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.- 8 module.Each284.0284.016.0FalseNoneNoneFalseNoneFalse4544.00
3921672151263NoneBOQ155Supplying and fixing superior quality switch mounting poly carbonate plate with necessary supporting back plate with required nos of machine tools, bolts, nuts etc., complete on the existing metal/PVC box.- 10-12 moduleEach344.0344.082.0FalseNoneNoneFalseNoneFalse28208.00
3921673151263NoneBOQ156Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS-3854 and IS 1293. 6Amps one way Switch .Each102.0102.0472.0FalseNoneNoneFalseNoneFalse48144.00
3921674151263NoneBOQ157Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS-3854 and IS 1293.- 6Amps two way Switch.Each166.0166.040.0FalseNoneNoneFalseNoneFalse6640.00
3921675151263NoneBOQ158Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS-3854 and IS 1293.- 6Amps 3way socket .Each171.0171.0232.0FalseNoneNoneFalseNoneFalse39672.00
3921676151263NoneBOQ159Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS-3854 and IS 1293. -Stepped Fan Regulator.Each357.0357.048.0FalseNoneNoneFalseNoneFalse17136.00
3921677151263NoneBOQ160Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS-3854 and IS 1293. - 6/16Amps One way switchEach180.0180.056.0FalseNoneNoneFalseNoneFalse10080.00
3921678151263NoneBOQ161Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS-3854 and IS 1293. - 6/16Amps universal socket.Each236.0236.056.0FalseNoneNoneFalseNoneFalse13216.00
3921679151263NoneBOQ162Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS-3854 and IS 1293. - 6Amps Bell Push .Each177.0177.08.0FalseNoneNoneFalseNoneFalse1416.00
3921680151263NoneBOQ163Supplying and fixing one of 230 V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote.Each246.0246.08.0FalseNoneNoneFalseNoneFalse1968.00
3921681151263NoneBOQ164Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS-3854 and IS 1293. TV/Telephone socketEach156.0156.032.0FalseNoneNoneFalseNoneFalse4992.00
3921682151263NoneBOQ165Supplying and drawing PVC flexible one pair telephone unarmoured tinned Copper cable. 2 pairMtr21.021.0120.0FalseNoneNoneFalseNoneFalse2520.00
3921683151263NoneBOQ166Supplying and drawing PVC insulated gas injected physical foam jelly flooded co-axial TV cable.RG-6.Mtr44.044.0300.0FalseNoneNoneFalseNoneFalse13200.00
3921684151263NoneBOQ167Supplying and fixing superior quality of modular switch & connected acceessories on existing modular switch plate as per IS-3854 and IS 1293. TV/ socket.Each156.0156.032.0FalseNoneNoneFalseNoneFalse4992.00
3921685151263NoneBOQ168Wiring for lighting /Power Circuit using one FRLS/PVC insulated 1100v Grade , multistand Copper with Low conductor resistance single core wire in open or concealed system of wiring with specified IS 694 : 2010 confirming to latest amemndments-1.5 Sqmm. ( Lighting & Power Circuit Earthing) -Mtr26.026.02400.0FalseNoneNoneFalseNoneFalse62400.00
3921686151263NoneBOQ169Wiring for lighting /Power Circuit using one FRLS/PVC insulated 1100v Grade , multistand Copper with Low conductor resistance single core wire in open or concealed system of wiring with specified IS 694 confirming to latest amemndments- 2.5 Sqmm. ( Lighting & 15A Power Circuit Phase & Neutral + AC Circuit and Geyser earthing)Mtr42.042.03600.0FalseNoneNoneFalseNoneFalse151200.00
3921687151263NoneBOQ170Wiring for lighting /Power Circuit using one FRLS/PVC insulated 1100v Grade , multistand Copper with Low conductor resistance single core wire in open or concealed system of wiring with specified IS 694 confirming to latest amemndments-4 Sqmm.( AC and Geyser Phase & Neutral)Mtr63.063.01600.0FalseNoneNoneFalseNoneFalse100800.00
3921688151263NoneBOQ171Wiring for lighting /Power Circuit using one FRLS/PVC insulated 1100v Grade , multistand Copper with Low conductor resistance single core wire in open or concealed system of wiring with specified IS 694 confirming to latest amemndments-6 Sqmm.( Earthing from Metering panel to TPN DB )Mtr92.092.0400.0FalseNoneNoneFalseNoneFalse36800.00
3921689151263NoneBOQ172Wiring for lighting /Power Circuit using one FRLS/PVC insulated 1100v Grade , multistand Copper with Low conductor resistance single core wire in open or concealed system of wiring with specified IS 694 confirming to latest amemndments- 10Sqmm. ( For Main Incomer from Metering Panel to TPN DB)Mtr167.0167.0640.0FalseNoneNoneFalseNoneFalse106880.00
3921690151263NoneBOQ173Supplying and fixing of .4' feet PVC Batten with integrated LED tube 20/22.W with high quality diffuser with Life of 25000 burning hours & 70 lumen maintenance with CRI gretater 80. Power Input: 220-240V 50/60Hz & Power factor greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.4 feet LED Fitting.Each690.0690.0102.0FalseNoneNoneFalseNoneFalse70380.00
3921691151263NoneBOQ174Supplying and fixing of .2' feet - PVC Batten with integrated LED tube9/10.W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greater thaan 80. Power Input: 220-240V @ 50/60Hz & Power factor greater than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.2 feet LED Fitting Mirror lighting fitting .Each551.0551.016.0FalseNoneNoneFalseNoneFalse8816.00
3921692151263NoneBOQ175Supplying & fixing of retrofit type LED bulb .12W,65000k with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIgreater than 70%. efficacy greater than 80 lumen per W, life greater 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF greater than 0.95, power loss should lesser than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.( Cost including with necessary base fixing pedent type holder.)Each269.0269.080.0FalseNoneNoneFalseNoneFalse21520.00
3921693151263NoneBOQ176Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans)Each2677.02677.048.0FalseNoneNoneFalseNoneFalse128496.00
3921694151263NoneBOQ177Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5 A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each315.0315.048.0FalseNoneNoneFalseNoneFalse15120.00
3921695151263NoneBOQ178Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete.-12" Sweep (300mm)Each2969.02969.024.0FalseNoneNoneFalseNoneFalse71256.00
3921696151263NoneBOQ179Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each707.0707.024.0FalseNoneNoneFalseNoneFalse16968.00
3921697151263NoneBOQ180Supplying and fixing of round or oblong type bulk head fitting with glass cover and 12/15 watts LED lampEach900.0900.012.0FalseNoneNoneFalseNoneFalse10800.00
3921698151263NoneBOQ181Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely.Each971.0971.016.0FalseNoneNoneFalseNoneFalse15536.00
3921699151263NoneBOQ182Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. - 6-32A DPEach739.0739.016.0FalseNoneNoneFalseNoneFalse11824.00
3921700151263NoneBOQ183CONSUMER CONTROL TPN DB Supplying and fixing regular MCB distribution boards on wall/Wood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.- 6 WAY TP & N Double Door DB.Each4940.04940.09.0FalseNoneNoneFalseNoneFalse44460.00
3921701151263NoneBOQ184Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/panel board.( 63A 4 pole ).Each5545.05545.09.0FalseNoneNoneFalseNoneFalse49905.00
3921702151263NoneBOQ185Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC.Each3088.03088.09.0FalseNoneNoneFalseNoneFalse27792.00
3921703151263NoneBOQ1866-32 Amps Single pole MCB for Outgoing Circuits .(25A-2nos for AC + 20A - 2nos for Geyser + 16A -5nos for 15A power socket + 6A-10A -9 nos for lighting circuit.)Each415.0415.0162.0FalseNoneNoneFalseNoneFalse67230.00
3921704151263NoneBOQ187EB-METER BOARD Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.-600mm x 600mm x 170mmEach14520.014520.09.0FalseNoneNoneFalseNoneFalse130680.00
3921705151263NoneBOQ188Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440v A.C. 50 Hz 12/24v D.C.Each515.0515.027.0FalseNoneNoneFalseNoneFalse13905.00
3921706151263NoneBOQ189Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 32/63 A three phase 4 wire whole current class-1 Accuracy Energy Meter.Each5705.05705.09.0FalseNoneNoneFalseNoneFalse51345.00
3921707151263NoneBOQ190Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.-63A . (KPWD SR 2023-24 /Volume 6 / Part-3/ Item No: 5.7.3 /Pg.No: 14 of 105).Each401.0401.027.0FalseNoneNoneFalseNoneFalse10827.00
3921708151263NoneBOQ191Supplying of Switch disconnector fuse unit (TPN) HRC type (but without HRC fuses). With AC-23A duty and as per IS- 13947. - 63AEach2312.02312.09.0FalseNoneNoneFalseNoneFalse20808.00
3921709151263NoneBOQ192Supplying and fixing HRC fuse units base on existing switch / panel board.Each612.0612.027.0FalseNoneNoneFalseNoneFalse16524.00
3921710151263NoneBOQ193EARTHING Supplying, fixing, wiring, earth electrode for grounding conduits, I.C. cutouts and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit . The pit should be filled with equal proportion of salt and charcoal 150mm all-round the pipe to complete depth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3. of IS 732 using 12mm dia bolts, nuts, washers and check nuts etc., the pipe shall have 16 through holes of 12 mm dia.Each3510.03510.018.0FalseNoneNoneFalseNoneFalse63180.00
3921711151263NoneBOQ194Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.-25x3mm GI strip.Mtr82.082.0270.0FalseNoneNoneFalseNoneFalse22140.00
3921712151263NoneBOQ195Supplying and running GI/Copper conductor for grounding and (along with other wires in conduit system of wiring) using necessary suitable size clamps, nails, guttas/spacers etc. 8 SWG GI Wire.Mtr60.060.0225.0FalseNoneNoneFalseNoneFalse13500.00
3921713151263NoneBOQ196Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.- 35 sqmmEach50.050.072.0FalseNoneNoneFalseNoneFalse3600.00
3921714151263NoneBOQ197Supplying tinned copper lugs and crimping and wiring to terminal point for wire of the following sizes.- 50 sqmmEach80.080.08.0FalseNoneNoneFalseNoneFalse640.00
3921715151263NoneBOQ198Supplying and fixing of DANGER, NO-ADMISSION & NO SMOKING board made out of MS sheet metal with two coats of non corrosive enameled paintEach110.0110.018.0FalseNoneNoneFalseNoneFalse1980.00
3921716151263NoneBOQ199Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV.- 40mmm450.0450.015.0FalseNoneNoneFalseNoneFalse6750.00
3921717151263NoneBOQ200EB Incomer Cable -3.5C X 70 sq.mm XLPE Ar.Al.Cable Supply and Laying ( Cable QTY Approxmate only )Mtr450.0450.0100.0FalseNoneNoneFalseNoneFalse45000.00
3921718151263NoneBOQ201Supply and End termination of Above Cable Gland with 70sq.mm including required Alumminum Suitable legs and tape etcEach1200.01200.02.0FalseNoneNoneFalseNoneFalse2400.00
3921719151263NoneBOQ202EB Incomer Cable -3.5C X 25 sq.mm XLPE Ar.Al.Cable Supply and Laying ( Cable QTY Approxmate only )Mtr350.0350.0225.0FalseNoneNoneFalseNoneFalse78750.00
3921720151263NoneBOQ203Supply and End termination of Above Cable Gland with 25 sq.mm including required Alumminum Suitable legs and tape etcEach800.0800.026.0FalseNoneNoneFalseNoneFalse20800.00
3921721151263NoneBOQ204WARDROBE AND FURNISHING Providing and supplying cupboard shutter with 19mm thick one side Architect recommended decorative laminate (1mm thick) and other side balancing lamination(preferably white) on factory pressed BWP grade marine ply as per IS 710 of approved brand complete as per direction of engineer in-charge.(Payment for providing and fixing auto closing hinges shall be paid separately)(KPWD SR 2023-2024/Vol 2/Item No:22.3/Pg.No:217)Sqm3048.83048.877.0FalseNoneNoneFalseNoneFalse234757.60
3921722151263NoneBOQ205Providing and supplying Kitchen cabinet with 19mm thick one side Architect recommended decorative Acrylic Glossy or Matt finished laminate (1.5mm thick) and other side balancing lamination(preferably white) on factory pressed BWP grade marine ply as per IS 710 of approved brand . complete as per direction of engineer in-charge.Sqm3193.03193.050.0FalseNoneNoneFalseNoneFalse159650.00
3921723151263NoneBOQ206Providing and fixing stainless steel 304 grade fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-incharge.150 mm lengthNos1390.51390.580.0FalseNoneNoneFalseNoneFalse111240.00
3921724151263NoneBOQ207Providing and fixing stainless steel soft closing heavy type telescopic drawer channels of approved make 500 mm long with screws etc. complete as per directions of Engineer- in-charge.Nos267.8267.832.0FalseNoneNoneFalseNoneFalse8569.60
3921725151263NoneBOQ208Providing and fixing stainless steel 304 grade soft closing hinges with two hole fixing & 165 degrees turning option for Wardrobe, Doors, Kitchen & other utilities of reputed make with screws etc. complete as per directions of Engineer- in-chargeNos231.75231.75120.0FalseNoneNoneFalseNoneFalse27810.00
3921726151263NoneBOQ209Providing and fixing ready made 304 grade stainless steel Modular kitchen basket and accessories such as right angle basket (Plain Cup & Saucer, plant, Partition, Bottle rack, Thali, Cutlery) kitchen utensil basket,Dinner set basket, kitchen grain basket, Multipurpose basket as per site requirement including finishing (wherever required) and fittings. The same shall be fixed with necessary stainless steel nuts & bolts, Stainless Steel screws & telescopic channel etc. as per direction of Engineer-incharge. (For payment purpose only weight of Stainless steel basket shall be considered excluding weight of all fixing accessories such as nuts, bolts, fasteners telescopic basket channels etc. Payment of providing and fixing telescopic channel shall be paid separately )Nos3605.03605.016.0FalseNoneNoneFalseNoneFalse57680.00
3921727151263NoneBOQ210Providing and laying (Kitchen slab) flamed finish Granite sTonnee flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick sTonnee slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : ** Flamed finish granite sTonnee slab Black, Cat Eye, River Pink or equivalentSqm2539.982539.9850.0FalseNoneNoneFalseNoneFalse126999.00
3921728151263NoneBOQ211ROADWORK Plant Mix Method Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 For Grading -II MaterialCum2636.82636.8120.0FalseNoneNoneFalseNoneFalse316416.00
3921729151263NoneBOQ212Construction of un-reinforced plain cement concrete pavement using RMC M-30 grade with OPC @ 270 kg/m3 and GGBS@ 90 kg/m3 (75:25 proportion) as per approved mix design procedure and thickness as per design, over a prepared sub base. The superplastisiser confirming to IS 9103-1999 Reaffirmed-2008,Coarse aggregates and Fine aggregate confirming to IS:383-2016, transported to site, laid in approved fixed side form work (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the form work). Spreading the concrete with shovels, rackers and compacted using needle, suitable plate vibrator and finished in a continuous operation including provision of separation membrane and Hessian cloth finishing to lines and grades complete including cost of all materials, labour, all lead & lift, loading charges as per specification & direction of Engineer - incharge of the work.Cum6874.226874.2290.0FalseNoneNoneFalseNoneFalse618679.80
3921730151263NoneBOQ213Supplying and fixing M15 grade precast cement concrete Kerb sTonnees for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge..600 x 300 x 150 mm Kerb STonneem476.89476.89240.0FalseNoneNoneFalseNoneFalse114453.60
3921731151263NoneBOQ214Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per direction of Engineer-in-charge.Each1156.691156.69225.0FalseNoneNoneFalseNoneFalse260255.250
3921732151263NoneBOQ215BOREWELL Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) Borewell depth of 0 to 50 Mtrsm381.1381.150.0FalseNoneNoneFalseNoneFalse19055.00
3921733151263NoneBOQ216Borewell depth of 50 to 100 mm477.92477.9250.0FalseNoneNoneFalseNoneFalse23896.00
3921734151263NoneBOQ217Borewell depth of 100 to 150 mm507.79507.7950.0FalseNoneNoneFalseNoneFalse25389.50
3921735151263NoneBOQ218Borewell depth of 150 to 200 mm589.16589.1650.0FalseNoneNoneFalseNoneFalse29458.00
3921736151263NoneBOQ219Borewell depth of 200 to 250 mm691.13691.1350.0FalseNoneNoneFalseNoneFalse34556.50
3921737151263NoneBOQ220Borewell depth of 250 to 300 mm762.2762.250.0FalseNoneNoneFalseNoneFalse38110.00
3921738151263NoneBOQ221Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For:PVC pipes 160mm dia., 6 kg/sqcm & class 3m636.54636.5450.0FalseNoneNoneFalseNoneFalse31827.00
3921739151263NoneBOQ222Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.m1990.991990.9910.0FalseNoneNoneFalseNoneFalse19909.90
3921740151263NoneBOQ223Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendmentsEach154.5154.51.0FalseNoneNoneFalseNoneFalse154.50
3921741151263NoneBOQ224Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete. 10.00 HP - 90 LPM @ 220 m = 20 STG Outlet Dia - 2.00"Each56250.3656250.361.0FalseNoneNoneFalseNoneFalse56250.360
3921742151263NoneBOQ225Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work.Job6695.06695.01.0FalseNoneNoneFalseNoneFalse6695.00
3921743151263NoneBOQ226Rewinding of submersible pumpset with copper winding wires of appropriate guage, as per specifications and / or directions of the departmental officials, including all materials, labour, equipment and testing. for all types of submersible pumpsets etc.(with guarantee period not less than 6 months) for For all types of submersible pumpsets above 9.5 HP and upto 10.0H.P.Each4886.324886.321.0FalseNoneNoneFalseNoneFalse4886.320
3921744151263NoneBOQ227Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments..1x3x6sqmmm190.55190.55350.0FalseNoneNoneFalseNoneFalse66692.50
3921745151263NoneBOQ228Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete. 6 to 15 HP pumpsEach18025.018025.01.0FalseNoneNoneFalseNoneFalse18025.00
3921746151263NoneBOQ229Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work.Job1493.51493.51.0FalseNoneNoneFalseNoneFalse1493.50
3921747151263NoneBOQ230Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) Heavy Duty GI pipe of 65mm diam859.02859.02350.0FalseNoneNoneFalseNoneFalse300657.00
3921748151263NoneBOQ231Lowering, Laying and Jointing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) for etc. complete.65mm diam167.89167.89350.0FalseNoneNoneFalseNoneFalse58761.50
3921749151263NoneBOQ232Supply and delivery at site wrought middle steel (galvanized) GI elbow confirming to IS 1239-II, 1991 with latest amendments if any for:For 65 mm dia GI elbowEach305.91305.912.0FalseNoneNoneFalseNoneFalse611.820
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17254530270000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17254530270000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17254530270000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17254530270000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17254530270000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17254530700000NoneNoneELIGIBILITYThe rates quoted shall includes provision for payment towards Employees welfare cess as per prevailing GOK Act.None
17254530800000NoneNoneELIGIBILITYThe Contractor should quote the item wise rates Excluding GST.None
17254531470001NoneNoneELIGIBILITYThe contractor shall quote item wise rates in the tender and the same shall holds good till the works are completed. The rates should include provision for payment of Royalty or any other such taxes due to the Corporation/Government notified by the Government time to time other than GST. The rates quoted should be inclusive of all lead and lift for materials etc.None
17254562860000NoneNoneELIGIBILITYAll other terms and conditions as per NIT and KW4None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneThe bidders shall upload the work done certificate for having executed One building work of value not less than Rs. 161.00 lakhs and completed satisfactorily as a prime contractor within stipulated time period in the past 5 years (i.e., F/Y 2019-20 to 2023-24). Work done certificate shall be duly signed by the officer not below the rank of Executive Engineer or equivalent.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneThe bidders shall upload a valid registered KPWD Civil contractor Licence of Class II and above.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneThe bidders shall achieved turnover for an amount not less than Rs.644.00 lakhs achieved in any two financial years in the past 5 years (i.e. F/Y 2019-20 to 2023-24) (in all classes of civil engineering construction works only). The Turnover certificate along with Balance sheet and P & L statement of past 5 years for the Civil Engineering works only (i.e. F/Y 2019-20 to 2023-24) issued from a Registered Chartered Accountant (Registered Chartered Accountant PIN and UDIN number must be mentioned failing which bid will considered Non-Responsive) should be uploaded.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Annual Turnover Certificate Along with P&L statements of past 5 years as per NIT and KW4
NoneNoneNoneNoneThe bidders shall upload the work done certificate for minimum quantities of work executed in any one year, for following quantities (In a continuous period of 12 months from April to March) in the last 5 years (i.e. F/Y 2019-20 to 2023-24) the certificate shall be issued by the officer not below the rank of Executive Engineer or equivalent. a.PCC/RCC -570.00 Cum b.Burnt brick masonry/Solid block masonry -318.00Cum / 1380.00 Sqm c.TMT steel reinforcement -53.00 Tonnes d.Vitrified / Ceramic / Granite flooring -950.00 SqmOthersMinimum Quantities Certificate as per NIT and KW4
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Minimum Quantities Certificate as per NIT and KW4
NoneNoneNoneNoneThe bidder/tenderer or his identified Sub contractor should upload required valid electrical licence along with consent / undertaking letter for executing building electrification works and should have executed similar electrical works totalling for Rs.11.00 lakhs in any one year in the last 5 years, (i.e. F/Y 2019-20 to 2023-24) signed by the officer not below the rank of Executive Engineer or equivalent for Electrical works.OthersElectrical licence, consent letter and Electrical workdone as per NIT and KW4
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Electrical licence, consent letter and Electrical workdone as per NIT and KW4
NoneNoneNoneNoneThe banker certificate pertaining to Liquid Assets for availability of fund requirement for the work not less Rs.97.00 Lakhs issued by Nationalised / Scheduled Bank for the subject work addressed to General Manager (Civil), Corporate office, BESCOM after 31.08.2024 in the enclosed format.OthersBanker certificate As per Enclosed format as per NIT and KW4
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Banker certificate As per Enclosed format as per NIT and KW4
NoneNoneNoneNoneBidders who meet the above specified minimum qualifying criteria, will only be qualified, if their available tender capacity is more than the total tender value. The bidder should calculate and upload available tender capacity as per the formula :Assessed available tender capacity : (AXNX1.5 - B) where, A -Maximum value of civil engineering works executed in any one year during the last five years updated to 2024-25 price level taking into account the completed as well as works in progress.N -Number of years prescribed for completion of the works for which tenders are invited.B -Value, at 2024-25 price level, of existing commitments and on-going works to be completed during the next 12 Months.OthersBid Capacity as per NIT and KW4
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Bid Capacity as per NIT and KW4
NoneNoneNoneNoneBidder shall upload the self-declaration affidavit as per the enclosed format on the stamp paper of value not less than Rs. 500/- duly notarized.OthersSelf-declaration affidavit as per the enclosed format on the stamp paper as per NIT and KW4
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Self-declaration affidavit as per the enclosed format on the stamp paper as per NIT and KW4
NoneNoneNoneNoneAll other terms and conditions as per NIT and KW4OthersAll other terms and conditions as per NIT and KW4
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- All other terms and conditions as per NIT and KW4
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
KPWD Registration Certificate as per NIT and KW4TrueTechnical Bid
Annual Turnover Certificate Along with P&L statements of past 5 years as per NIT and KW4TrueTechnical Bid
Workdone certificate as per NIT and KW4TrueTechnical Bid
Minimum Quantities Certificate as per NIT and KW4TrueTechnical Bid
Electrical licence, consent letter and Electrical workdone as per NIT and KW4TrueTechnical Bid
Banker certificate As per Enclosed format as per NIT and KW4TrueTechnical Bid
Bid Capacity as per NIT and KW4TrueTechnical Bid
Self-declaration affidavit as per the enclosed format on the stamp paper as per NIT and KW4TrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1725456417000
version0
createdDateNone
modifiedDateNone
blockNumberFirst floor, Belaku Bhavana, BESCOM Corporate office, K R Circle, Bengaluru
streetNone
cityBengaluru
stateKarnataka
pin560001
tenderRecallDTONone