1725430495000 | 1 | None | None | Other Works | Drilling Of Borewell And Construction of Cistern At Scheduled Caste Burial Ground In TMC Huvinahadagali Limits | 271069.66 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3913686 | 150943 | None | code01 | Dismantling of cement concrete pavement by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 m3 in volume and stock piling at designated locations and disposal of dismantled materials and stacking serviceable and unserviceable
materials separately. PWD SR 2023-24 Vol:3 P.NO.12 I.No:2.19 | Cum | 591.15 | 591.15 | 3.78 | False | None | None | False | None | False | 2234.547 | 0 | 3913687 | 150943 | None | code02 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kinds of soils. Depth upto 1.50 m, I.No 1.17.1, Page No. 10 PWD Common SR-2023-24 (V-1) | Cum | 275.1 | 275.1 | 45.0 | False | None | None | False | None | False | 12379.5 | 0 | 3913688 | 150943 | None | code03 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For. PVC pipes 75mm dia., 6 kg/sqcm & class 3, (Page no:113 item no.10.1.5) 2023-24 Common SR, BWSSB And KUWS & DB,Volume - 5, | Mtr | 231.0 | 231.0 | 100.0 | False | None | None | False | None | False | 23100.0 | 0 | 3913689 | 150943 | None | code04 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications. I.No 1.10, Page No.7, PWD Common SR-2023-24 (V-1) | Cum | 168.0 | 168.0 | 45.0 | False | None | None | False | None | False | 7560.0 | 0 | 3913690 | 150943 | None | code05 | Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. PWD SR 2023-24 Vol:3 P.NO.149 I.No: 16.28 | Cum | 7091.7 | 7091.7 | 2.52 | False | None | None | False | None | False | 17871.084 | 0 | 3913691 | 150943 | None | code06 | Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. Item No.12.4, Page No, 140, Volume - V | Each | 5552.4 | 5552.4 | 1.0 | False | None | None | False | None | False | 5552.4 | 0 | 3913692 | 150943 | None | code07 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) for: Item No.1, SOR Code O010, Page No, 151, 2023-24 Volume - V | Mtr | 1.0 | 1.0 | 1.0 | False | None | None | False | None | False | 1.0 | 0 | 3913693 | 150943 | None | code08 | a) Borewell depth of 0 to 50 m, Item No.12.1.1, SOR Code O020D, Page No, 139, Volume - V | Mtr | 388.5 | 388.5 | 50.0 | False | None | None | False | None | False | 19425.0 | 0 | 3913694 | 150943 | None | code09 | b) Borewell depth of 50 to 100 m, Item No.12.1.2, SOR Code O020D, Page No, 139, Volume - V | Mtr | 487.2 | 487.2 | 50.0 | False | None | None | False | None | False | 24360.0 | 0 | 3913695 | 150943 | None | code10 | c) Borewell depth of 100 to 150 m Item No.12.1.3, SOR Code O020D, Page No, 139,olume - V | Mtr | 517.65 | 517.65 | 50.0 | False | None | None | False | None | False | 25882.5 | 0 | 3913696 | 150943 | None | code11 | Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of pecials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4, 160mm dia. Item No.10.2.4, Page no.114, Volume - V | Mtr | 604.8 | 604.8 | 18.0 | False | None | None | False | None | False | 10886.4 | 0 | 3913697 | 150943 | None | code12 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 5.00 HP - 300 LPM @ 39 m = 5 STG Outlet Dia - 2.50" Item No.13.13.1, Page No, 151, Volume - V | Each | 27625.5 | 27625.5 | 1.0 | False | None | None | False | None | False | 27625.5 | 0 | 3913698 | 150943 | None | code13 | Submericable cables Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. Item No.13.22.2, Page No, 154, Volume - V | Mtr | 89.25 | 89.25 | 50.0 | False | None | None | False | None | False | 4462.5 | 0 | 3913699 | 150943 | None | code14 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. Item No.13.32, Page No, 156, Volume - V | Each | 6825.0 | 6825.0 | 1.0 | False | None | None | False | None | False | 6825.0 | 0 | 3913700 | 150943 | None | code15 | Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box. Item No.13.26, Page No, 155, Volume - V | Each | 1207.5 | 1207.5 | 1.0 | False | None | None | False | None | False | 1207.5 | 0 | 3913701 | 150943 | None | code16 | Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. Item No.13.33, Page No, 156, Volume - V | Each | 1417.5 | 1417.5 | 1.0 | False | None | None | False | None | False | 1417.5 | 0 | 3913702 | 150943 | None | code17 | Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit. Item No.13.36, Page No, 156, Volume - V | Each | 141.75 | 141.75 | 50.0 | False | None | None | False | None | False | 7087.5 | 0 | 3913703 | 150943 | None | code18 | Providing,Supplying and fixing suitable for 1.1 KV class UG cable filled with necessary bitumen/insulating compound complete with terminals, clamps,bolts,nuts and washers etc. with necessary materials and labour tools and equipments as per instructions of engineer incharge of work. Item No.13.38.1, Page No, 156, Volume - V | Each | 393.75 | 393.75 | 1.0 | False | None | None | False | None | False | 393.75 | 0 | 3913704 | 150943 | None | code19 | Indoor Type Board, Consist of 2 units meter Board unit & Panel board unit (a), One number of MS Box of size 350X380X150 mm fabricated out of 2mm thick sheet metal with sealable door and arrangement for mounting CT's (if any) to connect 3Ph/4 wire energy meter cable Box etc., complete a transperent glass peace should be provided for the protection where the energy meter reading could be read out, Up to 6 HP | Set | 8242.5 | 8242.5 | 1.0 | False | None | None | False | None | False | 8242.5 | 0 | 3913705 | 150943 | None | code20 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. Item No.13.39, Page No, 157, Volume - V | Job | 3937.5 | 3937.5 | 1.0 | False | None | None | False | None | False | 3937.5 | 0 | 3913706 | 150943 | None | code21 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. I.No.1.4.1, Page No 05, Vol 1 PWD Common SR 2023-24 for Engineering Departments | Cum | 254.1 | 254.1 | 2.376 | False | None | None | False | None | False | 603.7416 | 0 | 3913707 | 150943 | None | code22 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates. Volume No.-I, ITEM NO-2.1.2, PAGE NO-15. | Cum | 5947.2 | 5947.2 | 0.864 | False | None | None | False | None | False | 5138.3808 | 0 | 3913708 | 150943 | None | code23 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand), Volume No.-II, ITEM NO-5.4, PAGE NO-9. | Cum | 6708.45 | 6708.45 | 2.97 | False | None | None | False | None | False | 19924.0965 | 0 | 3913709 | 150943 | None | code24 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. I.No.8.19.1, Page No. 44, PWD Vol 2 Schedule of Rates for Buildings 2023-24 | Sqm | 267.75 | 267.75 | 3.15 | False | None | None | False | None | False | 843.4125 | 0 | 3913710 | 150943 | None | code25 | Providing and Filling in foundation with granite / trap broken metal 100mm. and
down size & with approved sand including hand packing, ramming, watering,
including cost of all materials and labour with all lead and lift complete as per
specifications. (V-1, 2023-24, I.No.1.23, P.No.11) | Cum | 2816.1 | 2816.1 | 0.294 | False | None | None | False | None | False | 827.9334 | 0 | 3913711 | 150943 | None | code26 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. I.No.2.4.1, P.No.16, Vol-1, 2023-24, Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6724.2 | 6724.2 | 0.657 | False | None | None | False | None | False | 4417.7994 | 0 | 3913712 | 150943 | None | code27 | RCC hume pipe Circular pump house: Providing precast RCC Circular Hume pipe pump house with M.S door and RCC conical roof as per specification and drawings - Internal dia Mtr. 1200 mm & height of 2.5 Mtr. With Wall thickness 65mm etc. complete. Item No.10.6, Page No, 116, 2023-24 Volume - V | No | 17221.05 | 17221.05 | 1.0 | False | None | None | False | None | False | 17221.05 | 0 | 3913713 | 150943 | None | code28 | Erection and positioning of RCC Hume pipe pump house/Cistern on size stone masory platform including transportation charges and handling, finishing with all necessary tools ,plants and materials etc.,complete as directed by the Engineer in charge of the work. Item No.10.7, Page No, 116, 2023-24 Volume - V | No | 1976.1 | 1976.1 | 1.0 | False | None | None | False | None | False | 1976.1 | 0 | 3913714 | 150943 | None | code29 | Distempering with dry distemper of approved brand and manufacture (two coats) of required shade on new work, over and including water thinnable priming coat to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. I.No.8.24, Page No. 45, PWD Vol 2 Schedule of Rates for Buildings 2023-24 | Sqm | 113.4 | 113.4 | 22.05 | False | None | None | False | None | False | 2500.47 | 0 | 3913715 | 150943 | None | code30 | Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For Medium Duty GI pipe of 80mm dia, Item No.11.2.8, Page No, 127, 2023-24 Volume - V | Mtr | 935.55 | 935.55 | 4.0 | False | None | None | False | None | False | 3742.2 | 0 | 3913716 | 150943 | None | code31 | Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For Medium Duty GI pipe of 32mm dia, Item No.11.2.4, Page No, 127, 2023-24 Volume - V | Mtr | 400.05 | 400.05 | 1.8 | False | None | None | False | None | False | 720.09 | 0 | 3913717 | 150943 | None | code32 | Supply and delivery at site wrought middle steel (galvanized) GI bend confirming to IS 1239-II, 1991 with latest amendments if any. For 80 mm dia GI BEND, Item No.11.8.8, Page No, 127, 2023-24 Volume - V | Each | 514.5 | 514.5 | 1.0 | False | None | None | False | None | False | 514.5 | 0 | 3913718 | 150943 | None | code33 | Providing wrought mild steel (galvanized) GI collar confirming to IS 1239-II, 1991 with latest amendments if any. For 32 mm dia GI collar:Item No.11.6.4, Page No, 129, 2023-24 Volume - V | Each | 184.8 | 184.8 | 4.0 | False | None | None | False | None | False | 739.2 | 0 | 3913719 | 150943 | None | code34 | Providing and fixing C.P. Brass bibcock 15 mm of approved quality : I.No.163, Page No. A-6, Vol 2 Schedule of Rates for Buildings 2023-24 | Each | 362.25 | 362.25 | 4.0 | False | None | None | False | None | False | 1449.0 | 0 |
|