1725432788000 | 0 | None | None | Other Works | Construction of Cistern to Drilled Borewell At Sewage Treatment Plant In TMC Huvinahadagali Limits | 86972.97 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3914254 | 150970 | None | code01 | Submericable cables Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. Item No.13.22.2, Page No, 154, Volume - V | Mtr | 89.25 | 89.25 | 50.0 | False | None | None | False | None | False | 4462.5 | 0 | 3914255 | 150970 | None | code02 | Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box. Item No.13.26, Page No, 155, Volume - V | Each | 1207.5 | 1207.5 | 1.0 | False | None | None | False | None | False | 1207.5 | 0 | 3914256 | 150970 | None | code03 | Labour charges for erection of indoor type panel board and meter board units with all necessary materials and labour tools and equipments including cement concrete for foundation/bed etc,complete as per specification, with testing of as per instructions of engineer incharge of work. Item No.13.33, Page No, 156, Volume - V | Each | 1417.5 | 1417.5 | 1.0 | False | None | None | False | None | False | 1417.5 | 0 | 3914257 | 150970 | None | code04 | Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554/ 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit. Item No.13.36, Page No, 156, Volume - V | Each | 141.75 | 141.75 | 50.0 | False | None | None | False | None | False | 7087.5 | 0 | 3914258 | 150970 | None | code05 | Indoor Type Board, Consist of 2 units meter Board unit & Panel board unit (a), One number of MS Box of size 350X380X150 mm fabricated out of 2mm thick sheet metal with sealable door and arrangement for mounting CT's (if any) to connect 3Ph/4 wire energy meter cable Box etc., complete a transperent glass peace should be provided for the protection where the energy meter reading could be read out, Up to 6 HP | Set | 8242.5 | 8242.5 | 1.0 | False | None | None | False | None | False | 8242.5 | 0 | 3914259 | 150970 | None | code06 | Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia. Item No.13.39, Page No, 157, Volume - V | Job | 3937.5 | 3937.5 | 1.0 | False | None | None | False | None | False | 3937.5 | 0 | 3914260 | 150970 | None | code07 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. I.No.1.4.1, Page No 05, Vol 1 PWD Common SR 2023-24 for Engineering Departments | Cum | 254.1 | 254.1 | 2.376 | False | None | None | False | None | False | 603.7416 | 0 | 3914261 | 150970 | None | code08 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates. Volume No.-I, ITEM NO-2.1.2, PAGE NO-15. | Cum | 5947.2 | 5947.2 | 0.864 | False | None | None | False | None | False | 5138.3808 | 0 | 3914262 | 150970 | None | code09 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand), Volume No.-II, ITEM NO-5.4, PAGE NO-9. | Cum | 6708.45 | 6708.45 | 2.97 | False | None | None | False | None | False | 19924.0965 | 0 | 3914263 | 150970 | None | code10 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lining, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge. I.No.8.19.1, Page No. 44, PWD Vol 2 Schedule of Rates for Buildings 2023-24 | Sqm | 267.75 | 267.75 | 3.15 | False | None | None | False | None | False | 843.4125 | 0 | 3914264 | 150970 | None | code11 | Providing and Filling in foundation with granite / trap broken metal 100mm. and
down size & with approved sand including hand packing, ramming, watering,
including cost of all materials and labour with all lead and lift complete as per
specifications. (V-1, 2023-24, I.No.1.23, P.No.11) | Cum | 2816.1 | 2816.1 | 0.294 | False | None | None | False | None | False | 827.9334 | 0 | 3914265 | 150970 | None | code12 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. I.No.2.4.1, P.No.16, Vol-1, 2023-24, Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6724.2 | 6724.2 | 0.657 | False | None | None | False | None | False | 4417.7994 | 0 | 3914266 | 150970 | None | code13 | RCC hume pipe Circular pump house: Providing precast RCC Circular Hume pipe pump house with M.S door and RCC conical roof as per specification and drawings - Internal dia Mtr. 1200 mm & height of 2.5 Mtr. With Wall thickness 65mm etc. complete. Item No.10.6, Page No, 116, 2023-24 Volume - V | No | 17221.05 | 17221.05 | 1.0 | False | None | None | False | None | False | 17221.05 | 0 | 3914267 | 150970 | None | code14 | Erection and positioning of RCC Hume pipe pump house/Cistern on size stone masory platform including transportation charges and handling, finishing with all necessary tools ,plants and materials etc.,complete as directed by the Engineer in charge of the work. Item No.10.7, Page No, 116, 2023-24 Volume - V | No | 1976.1 | 1976.1 | 1.0 | False | None | None | False | None | False | 1976.1 | 0 | 3914268 | 150970 | None | code15 | Distempering with dry distemper of approved brand and manufacture (two coats) of required shade on new work, over and including water thinnable priming coat to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. I.No.8.24, Page No. 45, PWD Vol 2 Schedule of Rates for Buildings 2023-24 | Sqm | 113.4 | 113.4 | 22.05 | False | None | None | False | None | False | 2500.47 | 0 | 3914269 | 150970 | None | code16 | Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For Medium Duty GI pipe of 80mm dia, Item No.11.2.8, Page No, 127, 2023-24 Volume - V | Mtr | 935.55 | 935.55 | 4.0 | False | None | None | False | None | False | 3742.2 | 0 | 3914270 | 150970 | None | code17 | Providing, Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For Medium Duty GI pipe of 32mm dia, Item No.11.2.4, Page No, 127, 2023-24 Volume - V | Mtr | 400.05 | 400.05 | 1.8 | False | None | None | False | None | False | 720.09 | 0 | 3914271 | 150970 | None | code18 | Supply and delivery at site wrought middle steel (galvanized) GI bend confirming to IS 1239-II, 1991 with latest amendments if any. For 80 mm dia GI BEND, Item No.11.8.8, Page No, 127, 2023-24 Volume - V | Each | 514.5 | 514.5 | 1.0 | False | None | None | False | None | False | 514.5 | 0 | 3914272 | 150970 | None | code19 | Providing wrought mild steel (galvanized) GI collar confirming to IS 1239-II, 1991 with latest amendments if any. For 32 mm dia GI collar:Item No.11.6.4, Page No, 129, 2023-24 Volume - V | Each | 184.8 | 184.8 | 4.0 | False | None | None | False | None | False | 739.2 | 0 | 3914273 | 150970 | None | code20 | Providing and fixing C.P. Brass bibcock 15 mm of approved quality : I.No.163, Page No. A-6, Vol 2 Schedule of Rates for Buildings 2023-24 | Each | 362.25 | 362.25 | 4.0 | False | None | None | False | None | False | 1449.0 | 0 |
|