1725437978000 | 1 | None | None | Buildings | Continued Rennovation Work of Old Taluk Office Building which Handed Over to Huvinahadagali TMC And Construction Of Toilet At Muslim Khabarstan in TMC Huvinahadagali Limits | 1497395.23 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3916022 | 151064 | None | code01 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. I.No.13.32.4, Page No.122, Vol-2, 2023-24 CSR | Mtr | 584.85 | 584.85 | 150.0 | False | None | None | False | None | False | 87727.5 | 0 | 3916023 | 151064 | None | code02 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. I.No.13.34, Page No.123, Vol-2, 2023-24 CSR | Ltr | 9.45 | 9.45 | 3000.0 | False | None | None | False | None | False | 28350.0 | 0 | 3916024 | 151064 | None | code03 | Providing and fixing Bib cock with wall flange made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class, I.No.14.55 a, Page No.139, Vol-2, 2023-24 CSR (Premium) | Each | 2547.3 | 2547.3 | 10.0 | False | None | None | False | None | False | 25473.0 | 0 | 3916025 | 151064 | None | code04 | Painting with oil type wood preservative of approved brand and manufacture: Old work (one coats) as per specifications and as per directions of Engineer in charge. I.No.8.62, Page No.51, Vol-2, 2023-24 CSR | Sqm | 32.55 | 32.55 | 298.92 | False | None | None | False | None | False | 9729.846 | 0 | 3916026 | 151064 | None | code05 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.. I.No.12.55.1, Page No.104, Vol-2, 2023-24 CSR | Sqm | 2484.3 | 2484.3 | 23.625 | False | None | None | False | None | False | 58691.5875 | 0 | 3916027 | 151064 | None | code06 | Removing of existing old or broken wash basin / urinals/ Indian Water closet/ European Water closet and disposing it with all cost and conveyance labour for all items of work, HOM with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. I.No.20.123, Page No.209, Vol-2, 2023-24 CSR | Each | 423.15 | 423.15 | 6.0 | False | None | None | False | None | False | 2538.9 | 0 | 3916028 | 151064 | None | code07 | Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Orissa pattern W.C Pan of size 580x440 mm. Common SR 2021-22 (V-2), I.No.20.44.2, Page No 202 | Each | 3724.35 | 3724.35 | 6.0 | False | None | None | False | None | False | 22346.1 | 0 | 3916029 | 151064 | None | code08 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550x400 mm with a pair of 15mm C.P. brass pillar taps, Common SR 2021-22 (V-2), I.No.14.17.3, Page No 132 | Each | 3009.3 | 3009.3 | 2.0 | False | None | None | False | None | False | 6018.6 | 0 | 3916030 | 151064 | None | code09 | Open Conduit System Supplying heavy gauge PVC conduit pipe 25 mm dia confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. (P.No.2, I.No.1. 1.3) PWD ELECTRICAL DSR. 2019-20 | Mtr | 96.6 | 96.6 | 680.0 | False | None | None | False | None | False | 65688.0 | 0 | 3916031 | 151064 | None | code10 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. (P.No.5, I.No.2.3) PWD ELECTRICAL DSR. 2019-20 I. 1 sqmm. (Copper wire) | Mtr | 14.7 | 14.7 | 500.0 | False | None | None | False | None | False | 7350.0 | 0 | 3916032 | 151064 | None | code11 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. (P.No.5, I.No.2.3) PWD ELECTRICAL DSR. 2019-20 I. 2.5 sqmm (Copper wire) | Mtr | 33.6 | 33.6 | 400.0 | False | None | None | False | None | False | 13440.0 | 0 | 3916033 | 151064 | None | code12 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. (P.No.5, I.No.2.3) PWD ELECTRICAL DSR. 2019-20 I. 4 sqmm (Copper wire) | Mtr | 47.25 | 47.25 | 400.0 | False | None | None | False | None | False | 18900.0 | 0 | 3916034 | 151064 | None | code13 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. (P.No.5, I.No.2.3) PWD ELECTRICAL DSR. 2019-20 I. 6 sqmm (Copper wire) | Mtr | 73.5 | 73.5 | 200.0 | False | None | None | False | None | False | 14700.0 | 0 | 3916035 | 151064 | None | code14 | Supplying and fixing PBBC bakelite straight or slant batten holder and wiring, within 60w/230 Volts lamps. Group 'A' (P.No.20, I.No.4.2) PWD ELECTRICAL DSR. 2019-20 | Each | 92.4 | 92.4 | 80.0 | False | None | None | False | None | False | 7392.0 | 0 | 3916036 | 151064 | None | code15 | Supply patty type fluorescent tube light fitting of 4'- 36/40 watts fluorescent tube fitting, made out of M.S sheet and stove enameled with low loss open construction copper wound ferromagnetic ballast, starter, locking type brass contact holders mounted on double fold type sheet base fully wired for use on 230 Volts A C Supply including 1No 4'-36/40Watts fluorescent tube. a.Group 'A' (P.No.20, I.No.4.6) PWD ELECTRICAL DSR. 2019-20 | Each | 702.45 | 702.45 | 3.0 | False | None | None | False | None | False | 2107.35 | 0 | 3916037 | 151064 | None | code16 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides with planks made out of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws etc. a) 20"x20"x2.5" (P.NO.44, I.No.6.6.6) PWD ELECTRICAL DSR. 2019-20 | Each | 317.1 | 317.1 | 66.0 | False | None | None | False | None | False | 20928.6 | 0 | 3916038 | 151064 | None | code17 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers etc., complete. 32Amps (P.No.44, I.No.6.7.2) PWD ELECTRICAL DSR. 2019-20 | Each | 189.0 | 189.0 | 14.0 | False | None | None | False | None | False | 2646.0 | 0 | 3916039 | 151064 | None | code18 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve , indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required. e) 5-32Amps Group 'A' (P.No.54, I.No.6.16.4 & 6.16.1) PWD ELECTRICAL DSR. 2019-20 | Each | 2032.8 | 2032.8 | 22.0 | False | None | None | False | None | False | 44721.6 | 0 | 3916040 | 151064 | None | code19 | Supplying and fixing PVC/metal conduit Deep junction box. PWD ELECTRICAL DSR. 2019-20, I.No.1.5.3, Page No.3 | Each | 63.0 | 63.0 | 88.0 | False | None | None | False | None | False | 5544.0 | 0 | 3916041 | 151064 | None | code20 | Extra for supplying 4mm thick white plastic plate and covering for junction boxes of size ……mm conduit using necessary machine screws. PWD ELECTRICAL DSR. 2019-20, I.No.3.10, Page No.10 | Each | 11.55 | 11.55 | 88.0 | False | None | None | False | None | False | 1016.4 | 0 | 3916042 | 151064 | None | code21 | Mechanical Means: Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. (Page no: 8 item no:1.12) V-1, 2023-24 | Cum | 99.75 | 99.75 | 59.94 | False | None | None | False | None | False | 5979.015 | 0 | 3916043 | 151064 | None | code22 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse (Page no: 15 item no:2.1.3) V-1, 2023-24 | Cum | 6288.45 | 6288.45 | 6.66 | False | None | None | False | None | False | 41881.077 | 0 | 3916044 | 151064 | None | code23 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) (Page no: 18 item no:2.11a) V-1, 2023-24 | Kg | 93.93 | 93.93 | 1299.2 | False | None | None | False | None | False | 122033.856 | 0 | 3916045 | 151064 | None | code24 | Add 35% Additionalities for Formwork, Centering & Scaffolding Percentage on finished rate of concrete per m3 | Cum | 2323.7 | 2323.7 | 21.46 | False | None | None | False | None | False | 49866.602 | 0 | 3916046 | 151064 | None | code25 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, rrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paidseparately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Page no:17 item no:2.4.2) | Cum | 6639.15 | 6639.15 | 21.46 | False | None | None | False | None | False | 142476.159 | 0 | 3916047 | 151064 | None | code26 | Loosening, levelling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. PWD SR 2023-24 Vol:3 P.NO.17 I.No:3.7 | Cum | 110.25 | 110.25 | 54.9525 | False | None | None | False | None | False | 6058.513125 | 0 | 3916048 | 151064 | None | code27 | Removal of Unserviceable Soil with Disposal up to a suitable distance as directed by the Engineer in charge of work, PWD SR 2023-24 Vol:3 P.NO.17 I.No:3.1 | Cum | 89.25 | 89.25 | 54.9525 | False | None | None | False | None | False | 4904.510625 | 0 | 3916049 | 151064 | None | code28 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. PWD SR 2023-24 Vol:3 P.NO.26 I.No: 4.17 | Cum | 2686.95 | 2686.95 | 54.9525 | False | None | None | False | None | False | 147654.619875 | 0 | 3916050 | 151064 | None | code29 | Providing and constructing un-reinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, , primer, sealant , curing of concrete slabs for 14-days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading & unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineer-in-charge of the work. PWD SR 2023-24 Vol:3 P.NO.149 I.No: 16.28 | Cum | 7091.7 | 7091.7 | 54.9525 | False | None | None | False | None | False | 389706.64425 | 0 | 3916051 | 151064 | None | code30 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Common SR 2023-24 (V-1), I.No.1.9, Page No.7 | Cum | 279.3 | 279.3 | 7.872 | False | None | None | False | None | False | 2198.6496 | 0 | 3916052 | 151064 | None | code31 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (Common SR 2023-24, I.No.2.11a, P.No.18) | Tonne | 93929.85 | 93929.85 | 0.1449 | False | None | None | False | None | False | 13610.435265 | 0 | 3916053 | 151064 | None | code32 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. Common SR 2023-24 (V-2), I.No.11.34B, Page No85 | Kg | 192.15 | 192.15 | 46.575 | False | None | None | False | None | False | 8949.38625 | 0 | 3916054 | 151064 | None | code33 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Common SR 2023-24 (V-2), I.No.11.34B, Page No85 | Kg | 142.8 | 142.8 | 400.0 | False | None | None | False | None | False | 57120.0 | 0 | 3916055 | 151064 | None | code34 | Providing & fixing corrugated G.S. sheet roofing including vertical /curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. Common SR 2023-24 (V-2), I.No.11.34B, Page No85 | Sqm | 922.95 | 922.95 | 15.75 | False | None | None | False | None | False | 14536.4625 | 0 | 3916056 | 151064 | None | code35 | Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. I.No.11.5.2, Page No.77, Vol-2, 2023-24 CSR | Sqm | 4454.1 | 4454.1 | 1.89 | False | None | None | False | None | False | 8418.249 | 0 | 3916057 | 151064 | None | code36 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.. I.No.12.55.1, Page No.104, Vol-2, 2023-24 CSR | Sqm | 2484.3 | 2484.3 | 4.725 | False | None | None | False | None | False | 11738.3175 | 0 | 3916058 | 151064 | None | code37 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. I.No.13.32.4, Page No.122, Vol-2, 2023-24 CSR | Mtr | 584.85 | 584.85 | 21.0 | False | None | None | False | None | False | 12281.85 | 0 | 3916059 | 151064 | None | code38 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. I.No.13.34, Page No.123, Vol-2, 2023-24 CSR | Ltr | 9.45 | 9.45 | 500.0 | False | None | None | False | None | False | 4725.0 | 0 | 3916060 | 151064 | None | code39 | Providing and fixing PTMT bib cock of approved quality and colour. 15mm nominal bore, 86 mm long, weighing not less than 88 g, I.No.13.17.1, Page No.120, Vol-2, 2023-24 CSR | Each | 165.9 | 165.9 | 3.0 | False | None | None | False | None | False | 497.7 | 0 | 3916061 | 151064 | None | code40 | Providing & fixing White vitreous china water closet squatting pan (Indian type) along with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site complete with all operations including all necessary materials, labour and disposal of dismantled material i/c malba, all complete as per the direction of Engineer-in charge. Orissa pattern W.C Pan of size 580x440 mm. Common SR 2021-22 (V-2), I.No.20.44.2, Page No 202 | Each | 3724.35 | 3724.35 | 2.0 | False | None | None | False | None | False | 7448.7 | 0 |
|