createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1725516556973
version10
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee7500.00
emd3937000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose23-09-2024 17:30:00
tenderQueryClose11-09-2024 16:30:00
technicalBidOpen25-09-2024 11:30:00
publishedDate05-09-2024 12:07:26
publishedByPostRGUHSK_REG_BNG
publishedByUserKPE12366 - SHIVAPRASAD P R
bidValidityPeriod120
noOfCalls2
preBidMeetingDate12-09-2024 12:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnTrue
percentageRateTypeTextNone
contactPersonOffice of the Registrar
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08029601928
mobileNumber9902319092
tenderSupplierListNone
tenderSchedule
createdTs1725516556976
version19
createdDateNone
modifiedDateNone
tenderNumberRGUHSK/2023-24/BD/WORK_INDENT4/CALL-2
titleConstruction of Regional centre along with Skill Labs, Research Labs and Indoor sports facilities for RGUHS at Mangaluru
descriptionConstruction of Regional centre along with Skill Labs, Research Labs and Indoor sports facilities for RGUHS at Mangaluru
categoryWORKS
categoryTextWorks
ecv393602177.20
deptNameRajiv Gandhi University of Health Sciences Bengaluru
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location8492
locationNameRajiv Gandhi University of Health Sciences
provisionalAmount497500000.0
groupOverheadTotalNone
fileNumberRGU/ENG/CON/REG/CEN/MAG/34/2020-21
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17255165570000NoneNoneBuildingsConstruction of Regional centre along with Skill Labs, Research Labs and Indoor sports facilities for RGUHS at Mangaluru393602177.2
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3924497151381NoneMan01Earth work in surface excavation by mechanical means for lowering & leveling the ground without blasting for all works other than foundation in Ordinary/Soft rock & depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In Ordinary/Soft rock upto 300 mm depthCum380.1380.11230.0FalseNoneNoneFalseNoneFalse467523.00
3924498151381NoneMan02Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work. In ordinary soft rock without blasting including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. : (i). DEPTH : 0 to 1.50 mts DEPTHCum381.15381.154367.0FalseNoneNoneFalseNoneFalse1664482.050
3924499151381NoneMan03Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work. In ordinary soft rock without blasting including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. : (ii). DEPTH : 1.50 to 3.00 mts DEPTHCum446.25446.253747.0FalseNoneNoneFalseNoneFalse1672098.750
3924500151381NoneMan04Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work. In ordinary soft rock without blasting including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. : (ii). DEPTH: 3.00 to 4.50mCum486.15486.152621.0FalseNoneNoneFalseNoneFalse1274199.150
3924501151381NoneMan05Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work. In ordinary soft rock without blasting including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. : (iii). DEPTH: 4.50 to 6.00mCum510.46510.462043.0FalseNoneNoneFalseNoneFalse1042869.780
3924502151381NoneMan06Earth work excavation for Foundation by mechanical means for all works and depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting and stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery and other appurtenaces required to complete the work. In ordinary soft rock without blasting including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. : (iv). DEPTH: 6.00 to 6.30mCum515.32515.32380.0FalseNoneNoneFalseNoneFalse195821.60
3924503151381NoneMan07Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery and all other appurtenaces required to complete the work including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. In Hard Rock ( requiring blasting) : (i). DEPTH : 0 1.50 mts DEPTHCum581.7581.7390.0FalseNoneNoneFalseNoneFalse226863.00
3924504151381NoneMan08Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery and all other appurtenaces required to complete the work including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. In Hard Rock ( requiring blasting) : (ii). DEPTH : 1.50 3.00 mts DEPTHCum654.15654.15350.0FalseNoneNoneFalseNoneFalse228952.50
3924505151381NoneMan09Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery and all other appurtenaces required to complete the work including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. In Hard Rock ( requiring blasting) : (ii). DEPTH: 3.00 to 4.50mCum746.55746.55210.0FalseNoneNoneFalseNoneFalse156775.50
3924506151381NoneMan10Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery and all other appurtenaces required to complete the work including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. In Hard Rock (requiring blasting) : (iii). DEPTH: 4.50 to 6.00mCum783.88783.88180.0FalseNoneNoneFalseNoneFalse141098.40
3924507151381NoneMan11Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery and all other appurtenaces required to complete the work including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. In Hard Rock (requiring blasting) : (iv). DEPTH: 6.00 to 6.30mCum791.34791.3440.0FalseNoneNoneFalseNoneFalse31653.60
3924508151381NoneMan12Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel vibratory roller in stages to proper grade and camber, applying and brooming requisite type of screening binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. Mechanical means GradingII (53 mm to 22.4 mm) Using Screening Crushable type such as Moorum or Gravel : (i). Ground Floor: (Level 02):Cum2272.22272.2420.0FalseNoneNoneFalseNoneFalse954324.00
3924509151381NoneMan13Wet Mix Macadam (Plant mix method): KSRRB Wet Mix Macadam (Plant mix method) Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver grader in subbase base course on well prepared surface and compacting with vibratory roller to achieve the desired density. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. : (ii). Ground Floor: (Level 02):Cum2686.952686.95310.0FalseNoneNoneFalseNoneFalse832954.50
3924510151381NoneMan14Disposal of debris : Loading and Unloading of Stone Boulder Stone aggregates Sand Kanker Moorum. Loading and Unloading of Stone Boulder Stone aggregates Sand Kankar Moorum. (Tipper 10 m3) Cost of Haulage Excluding Loading and Unloading Case 1: Surface Road. A. Taking output 10 t load and lead 10 km = 100 t.kmw including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. .10 KMCum137.55137.558604.0FalseNoneNoneFalseNoneFalse1183480.20
3924511151381NoneMan15Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m including with all labour, all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works.Cum279.3279.37466.0FalseNoneNoneFalseNoneFalse2085253.80
3924512151381NoneMan16Providing and injecting chemical emulsion for Preconstructional AntiTermite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20percent E.C. Lindane 20percent E.C. at 3.19 l m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Plinth area of the building at ground floor only shall be measured)Sqm123.9123.91985.0FalseNoneNoneFalseNoneFalse245941.50
3924513151381NoneMan17Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately)including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates FOUNDATIONCum6723.696723.69144.0FalseNoneNoneFalseNoneFalse968211.360
3924514151381NoneMan18Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately)including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. PLINTH BEAMCum6723.696723.6923.0FalseNoneNoneFalseNoneFalse154644.870
3924515151381NoneMan19Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately)including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. Sub Base: Lower Basement 01: (Level 01):Cum6723.696723.69289.0FalseNoneNoneFalseNoneFalse1943146.410
3924516151381NoneMan20Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately)including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. Flagging and Above Entry StepsCum6723.696723.6916.0FalseNoneNoneFalseNoneFalse107579.040
3924517151381NoneMan21Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately)including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. Below SSM:Cum6723.696723.693.0FalseNoneNoneFalseNoneFalse20171.070
3924518151381NoneMan22Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately)including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. CILL:Cum6723.696723.691.0FalseNoneNoneFalseNoneFalse6723.690
3924519151381NoneMan23READY MIX CONCRETE : Providing and laying in position Reinforced cement concrete for all Foundation works. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately) M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum] RAFT SLABCum7369.877369.87107.0FalseNoneNoneFalseNoneFalse788576.090
3924520151381NoneMan24READY MIX CONCRETE : Providing and laying in position Reinforced cement concrete for all Foundation works. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 340 Kgs Cum]: RAFT SLAB Foundation : (M 25 GRADE)Cum7185.027185.02867.0FalseNoneNoneFalseNoneFalse6229412.340
3924521151381NoneMan25Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.[Cement 360 Kgs Cum]: RETAINING WALL (M 30 GRADE): SUB STRUCTURE : (a). UP TO 1.40m LVLCum7787.017787.01202.0FalseNoneNoneFalseNoneFalse1572976.020
3924522151381NoneMan26Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates.[Cement 360 Kgs Cum]: For COLUMNS : (M 30 GRADE): SUB STRUCTURE FLOOR:Cum12034.4712034.4752.0FalseNoneNoneFalseNoneFalse625792.440
3924523151381NoneMan27Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum] : RETAINING WALL (M 30 GRADE): LOWER BASEMENT 01: LEVEL 01Cum7628.787628.78390.0FalseNoneNoneFalseNoneFalse2975224.20
3924524151381NoneMan28Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 340 Kgs Cum] : RETAINING WALL (M 25 GRADE): Collection SumpCum7484.47484.437.0FalseNoneNoneFalseNoneFalse276922.80
3924525151381NoneMan29Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum] : COLUMNS: (M 30 GRADE): LOWER BASEMENT 01: LEVEL 01Cum11789.9311789.9354.0FalseNoneNoneFalseNoneFalse636656.220
3924526151381NoneMan30Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works and other parallel works from 0.50m to 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The Cost of formwork included but steel reinforcement cost shall be paid separately but formwork cost included). [Cement 340 Kgs Cum] M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. COLUMNS M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11309.7611309.761.0FalseNoneNoneFalseNoneFalse11309.760
3924527151381NoneMan31Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum] : For PLINTH Beams : Regular (M 30 GRADE): Lower Basement 01(Level 01):Cum10402.8810402.8832.0FalseNoneNoneFalseNoneFalse332892.160
3924528151381NoneMan32Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately but formwork cost included) PLINTH BEAM: M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10206.010206.01.0FalseNoneNoneFalseNoneFalse10206.00
3924529151381NoneMan33Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum] : For Beams : Regular (M 30 GRADE): Lower Basement 01 (Level 01):Cum11096.411096.4196.0FalseNoneNoneFalseNoneFalse2174894.40
3924530151381NoneMan34Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum] : For Lintels: (M 30 GRADE): Lower Basement 01 (Level 01):Cum11096.411096.43.0FalseNoneNoneFalseNoneFalse33289.20
3924531151381NoneMan35Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum] : For Slabs (M 30 GRADE): Lower Basement 01 (Level 01):Cum10402.8810402.88378.0FalseNoneNoneFalseNoneFalse3932288.640
3924532151381NoneMan36Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 340 Kgs Cum] : For Slabs (M 25 GRADE): Lower Basement 01 (Level 01):Cum10206.010206.04.0FalseNoneNoneFalseNoneFalse40824.00
3924533151381NoneMan37Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum] : for CILL (M 30 GRADE): Lower Basement 01(Level 01):Cum10402.8810402.881.0FalseNoneNoneFalseNoneFalse10402.880
3924534151381NoneMan38Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum] : for Staircase (M 30 GRADE): Lower Basement 01 (Level 01):Cum10402.8810402.8810.0FalseNoneNoneFalseNoneFalse104028.80
3924535151381NoneMan39Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum] : for Ramp Beam (M 30 GRADE): Lower Basement 01:Cum11096.411096.422.0FalseNoneNoneFalseNoneFalse244120.80
3924536151381NoneMan40Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum] : for Ramp Slab (M 30 GRADE) : Lower Basement 01:Cum10402.8810402.8846.0FalseNoneNoneFalseNoneFalse478532.480
3924537151381NoneMan41Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum] : for Ramp Parapet Wall (M 30 GRADE) : Lower Basement 01:Cum7628.787628.7820.0FalseNoneNoneFalseNoneFalse152575.60
3924538151381NoneMan42Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum] : for Grade Slab (M 30GRADE): Lower Basement 01: (Level 01):Cum7143.317143.31270.0FalseNoneNoneFalseNoneFalse1928693.70
3924539151381NoneMan43Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]: RETAINING WALL (M 30 GRADE): GROUND FLOOR: Level 02Cum8093.098093.0915.0FalseNoneNoneFalseNoneFalse121396.350
3924540151381NoneMan44Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]: RETAINING WALL (M 30 GRADE): FIRST FLOOR: Level 03Cum8174.028174.0215.0FalseNoneNoneFalseNoneFalse122610.30
3924541151381NoneMan45Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]: RETAINING WALL (M 30 GRADE): SECOND FLOOR: Level 04Cum8255.768255.7680.0FalseNoneNoneFalseNoneFalse660460.80
3924542151381NoneMan46Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]: RETAINING WALL (M 30 GRADE): THIRD FLOOR: Level 05Cum8338.328338.3215.0FalseNoneNoneFalseNoneFalse125074.80
3924543151381NoneMan47Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]: RETAINING WALL (M 30 GRADE): FOURTH FLOOR: Level 06Cum8421.78421.715.0FalseNoneNoneFalseNoneFalse126325.50
3924544151381NoneMan48Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]: RETAINING WALL (M 30 GRADE): FIFTH FLOOR: Level 07Cum8505.928505.925.0FalseNoneNoneFalseNoneFalse42529.60
3924545151381NoneMan49Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]: RETAINING WALL (M 30 GRADE): SIXTH FLOOR: Level 07Cum8590.988590.9825.0FalseNoneNoneFalseNoneFalse214774.50
3924546151381NoneMan50Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For COLUMNS : (M 30 GRADE) : GROUND FLOOR: LEVEL 02Cum12507.512507.560.0FalseNoneNoneFalseNoneFalse750450.00
3924547151381NoneMan51Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The Cost of formwork included but steel reinforcement cost shall be paid separately) M 20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 320 Kgs Cum]. . M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates : For COLUMNS : GROUND FLOORCum12214.7612214.762.0FalseNoneNoneFalseNoneFalse24429.520
3924548151381NoneMan52Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For COLUMNS : (M 30 GRADE) : First FLOOR: LEVEL 03:Cum12632.5812632.5860.0FalseNoneNoneFalseNoneFalse757954.80
3924549151381NoneMan53Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For COLUMNS : (M 30 GRADE) : SECOND Floor: Level 04:Cum12758.9112758.9160.0FalseNoneNoneFalseNoneFalse765534.60
3924550151381NoneMan54Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For COLUMNS : (M 30 GRADE) : THIRD Floor: Level 05:Cum12886.512886.560.0FalseNoneNoneFalseNoneFalse773190.00
3924551151381NoneMan55Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For COLUMNS : (M 30 GRADE) : Fourth Floor: Level 06: UP TO 3.50m LVLCum13015.3713015.3744.0FalseNoneNoneFalseNoneFalse572676.280
3924552151381NoneMan56Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For COLUMNS : (M 30 GRADE) : Fourth Floor: Level 06: ABOVE 3.50m Up to 7.00 LVLCum13145.5213145.5222.0FalseNoneNoneFalseNoneFalse289201.440
3924553151381NoneMan57Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For COLUMNS : (M 30 GRADE) : Fourth Floor: Level 06: ABOVE 7.00m Up to 10.50 LVLCum13276.9813276.9818.0FalseNoneNoneFalseNoneFalse238985.640
3924554151381NoneMan58Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For COLUMNS : (M 30 GRADE) : Fifth Floor: Level 07:Cum13145.5213145.5230.0FalseNoneNoneFalseNoneFalse394365.60
3924555151381NoneMan59Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For COLUMNS : (M 30 GRADE) : SIXTH Floor: Level 08:Cum13276.9813276.9814.0FalseNoneNoneFalseNoneFalse185877.720
3924556151381NoneMan60Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Beams : Regular (M 30 GRADE): Ground Floor (Level 02):Cum11771.7611771.76100.0FalseNoneNoneFalseNoneFalse1177176.00
3924557151381NoneMan61Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Beams : Regular (M 30 GRADE): First Floor (Level 03):Cum11889.4811889.48115.0FalseNoneNoneFalseNoneFalse1367290.20
3924558151381NoneMan62Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Beams : Regular (M 30 GRADE): Second Floor (Level 04):Cum12008.3712008.37130.0FalseNoneNoneFalseNoneFalse1561088.10
3924559151381NoneMan63Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Beams : Regular (M 30 GRADE): Third Floor (Level 05):Cum12128.4512128.45135.0FalseNoneNoneFalseNoneFalse1637340.750
3924560151381NoneMan64Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Beams : Regular (M 30 GRADE): Fourth Floor (Level 06):Cum12249.7312249.7355.0FalseNoneNoneFalseNoneFalse673735.150
3924561151381NoneMan65Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Beams : Regular (M 30 GRADE): Fifth Floor (Level 08):Cum12372.2312372.235.0FalseNoneNoneFalseNoneFalse61861.150
3924562151381NoneMan66Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Beams : Regular (M 30 GRADE): Sixth Floor (Level 09):Cum12495.9512495.955.0FalseNoneNoneFalseNoneFalse62479.750
3924563151381NoneMan67Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars to be paid separately but cost of formwork included) M 20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 320 Kgs Cum]. . M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates :: GROUND FLOOR: REGULAR BEAMS ::Cum11496.2411496.241.0FalseNoneNoneFalseNoneFalse11496.240
3924564151381NoneMan68Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Lintels: (M 30 GRADE): Ground Floor (Level 02):Cum11771.7611771.764.0FalseNoneNoneFalseNoneFalse47087.040
3924565151381NoneMan69Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M 20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 320 Kgs Cum]. . M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates :: GROUND FLOOR: : LINTELS : GROUND FLOORCum11496.2411496.241.0FalseNoneNoneFalseNoneFalse11496.240
3924566151381NoneMan70Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Lintels: (M 30 GRADE): .First Floor (Level 03):Cum11889.4811889.484.0FalseNoneNoneFalseNoneFalse47557.920
3924567151381NoneMan71Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Lintels: (M 30 GRADE): Second Floor (Level 04):Cum12008.3712008.376.0FalseNoneNoneFalseNoneFalse72050.220
3924568151381NoneMan72Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Lintels: (M 30 GRADE): Third Floor (Level 05):Cum12128.4512128.456.0FalseNoneNoneFalseNoneFalse72770.70
3924569151381NoneMan73Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Lintels: (M 30 GRADE): Fourth Floor (Level 06):Cum12249.7312249.736.0FalseNoneNoneFalseNoneFalse73498.380
3924570151381NoneMan74Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Lintels: (M 30 GRADE): Fifth Floor (Level 07):Cum12372.2312372.236.0FalseNoneNoneFalseNoneFalse74233.380
3924571151381NoneMan75Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Slabs (M 30 GRADE): Ground Floor : (Level 02):Cum11036.0311036.03330.0FalseNoneNoneFalseNoneFalse3641889.90
3924572151381NoneMan76Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M 20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 320 Kgs Cum]. . M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates :: GROUND FLOOR: : SLABS : GROUND FLOOR :Cum10777.7310777.732.0FalseNoneNoneFalseNoneFalse21555.460
3924573151381NoneMan77Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Slabs (M 30 GRADE): First Floor : (Level 03):Cum11146.3911146.39365.0FalseNoneNoneFalseNoneFalse4068432.350
3924574151381NoneMan78Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Slabs (M 30 GRADE): Second Floor (Level 04):Cum11257.8511257.85330.0FalseNoneNoneFalseNoneFalse3715090.50
3924575151381NoneMan79Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Slabs (M 30 GRADE): Third Floor (Level 05):Cum11370.4311370.43360.0FalseNoneNoneFalseNoneFalse4093354.80
3924576151381NoneMan80Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Slabs (M 30 GRADE): Fourth Floor (Level 06):Cum11484.1311484.13400.0FalseNoneNoneFalseNoneFalse4593652.00
3924577151381NoneMan81Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Slabs (M 30 GRADE): Fifth Floor (Level 07):Cum11598.9711598.9725.0FalseNoneNoneFalseNoneFalse289974.250
3924578151381NoneMan82Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : For Slabs (M 30 GRADE): Sixth Floor (Level 08):Cum11714.9611714.9630.0FalseNoneNoneFalseNoneFalse351448.80
3924579151381NoneMan83Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : SLOPED SLAB: Second Floor (Level 04):Cum10882.5910882.5970.0FalseNoneNoneFalseNoneFalse761781.30
3924580151381NoneMan84Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M 25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 320 Kgs Cum]. . M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates :: GROUND FLOOR: CHAJJA : GROUND FLOOR :Cum10418.4710418.472.0FalseNoneNoneFalseNoneFalse20836.940
3924581151381NoneMan85Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : for CILL (M 30 GRADE): Ground Floor (Level 02):Cum11036.0311036.031.0FalseNoneNoneFalseNoneFalse11036.030
3924582151381NoneMan86Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : for CILL (M 30 GRADE): First Floor (Level 03):Cum11146.3911146.391.0FalseNoneNoneFalseNoneFalse11146.390
3924583151381NoneMan87Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : for CILL (M 30 GRADE): Second Floor (Level 04):Cum11257.8511257.8569.0FalseNoneNoneFalseNoneFalse776791.650
3924584151381NoneMan88Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : for CILL (M 30 GRADE): Third Floor (Level 05):Cum11370.4311370.431.0FalseNoneNoneFalseNoneFalse11370.430
3924585151381NoneMan89Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : for CILL (M 30 GRADE): Fourth Floor (Level 06):Cum11484.1311484.131.0FalseNoneNoneFalseNoneFalse11484.130
3924586151381NoneMan90Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : for CILL (M 30 GRADE): Fifth Floor (Level 07):Cum11598.9711598.971.0FalseNoneNoneFalseNoneFalse11598.970
3924587151381NoneMan91Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : COPING: GROUND FLOOR:Cum11036.0311036.031.0FalseNoneNoneFalseNoneFalse11036.030
3924588151381NoneMan92Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : COPING: First FLOOR:Cum11146.3911146.391.0FalseNoneNoneFalseNoneFalse11146.390
3924589151381NoneMan93Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : COPING: Second FLOOR:Cum11257.8511257.853.0FalseNoneNoneFalseNoneFalse33773.550
3924590151381NoneMan94Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : COPING: Third FLOOR:Cum11370.4311370.432.0FalseNoneNoneFalseNoneFalse22740.860
3924591151381NoneMan95Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : COPING: Fourth FLOOR:Cum11484.1311484.134.0FalseNoneNoneFalseNoneFalse45936.520
3924592151381NoneMan96Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : COPING: Fifth FLOOR:Cum11598.9711598.976.0FalseNoneNoneFalseNoneFalse69593.820
3924593151381NoneMan97Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : for Staircase (M 30 GRADE): Ground Floor: (Level 02)Cum11036.0311036.0310.0FalseNoneNoneFalseNoneFalse110360.30
3924594151381NoneMan98Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : for Staircase (M 30 GRADE): First Floor: (Level 03)Cum11146.3911146.3910.0FalseNoneNoneFalseNoneFalse111463.90
3924595151381NoneMan99Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : for Staircase (M 30 GRADE): Second Floor: (Level 04)Cum11257.8511257.8510.0FalseNoneNoneFalseNoneFalse112578.50
3924596151381NoneMan100Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all height.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : for Staircase (M 30 GRADE): Third Floor: (Level 05)Cum11370.4311370.4310.0FalseNoneNoneFalseNoneFalse113704.30
3924597151381NoneMan101Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications at all heights.(The cost of Formwork added but the reinforcement cost will be paid seperately) M 30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 360 Kgs Cum]. : for Staircase (M 30 GRADE): Fourth Floor: (Level 06)Cum11484.1311484.1312.0FalseNoneNoneFalseNoneFalse137809.560
3924598151381NoneMan102PLAIN CEMENT CONCRETE : Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates DUMMY RETAINING WALL: FIFTH FLOOR: Level 06Cum7546.927546.925.0FalseNoneNoneFalseNoneFalse37734.60
3924599151381NoneMan103PLAIN CEMENT CONCRETE : Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates DUMMY RETAINING WALL: For COLUMNS : Fifth Floor: Level 07Cum11663.4211663.428.0FalseNoneNoneFalseNoneFalse93307.360
3924600151381NoneMan104STEEL: Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping welding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification (The laps and wastages shall not be measured separately).: Sub Structure Floor :Tonne93929.8593929.8590.7FalseNoneNoneFalseNoneFalse8519437.3950
3924601151381NoneMan105STEEL: Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping welding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification at all heights. (The laps and wastages shall not be measured separately).:Lower Basement 01 (Level 01)Tonne93929.8593929.85117.5FalseNoneNoneFalseNoneFalse11036757.3750
3924602151381NoneMan106STEEL: Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping welding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification at all heights. (The laps and wastages shall not be measured separately).: Ground Floor: (Level 02) :Tonne93929.8593929.8591.0FalseNoneNoneFalseNoneFalse8547616.350
3924603151381NoneMan107STEEL: Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping welding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification at all heights. (The laps and wastages shall not be measured separately).: First Floor: (Level 03):Tonne94869.1594869.15127.0FalseNoneNoneFalseNoneFalse12048382.050
3924604151381NoneMan108STEEL: Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping welding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification at all heights. (The laps and wastages shall not be measured separately).: Second Floor: (Level 04):Tonne95817.8495817.8497.0FalseNoneNoneFalseNoneFalse9294330.480
3924605151381NoneMan109STEEL: Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping welding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification at all heights. (The laps and wastages shall not be measured separately).: Third Floor: (Level 05):Tonne96776.0296776.0281.0FalseNoneNoneFalseNoneFalse7838857.620
3924606151381NoneMan110STEEL: Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping welding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification at all heights. (The laps and wastages shall not be measured separately).: Fourth Floor: (Level 06):Tonne97743.7897743.7871.0FalseNoneNoneFalseNoneFalse6939808.380
3924607151381NoneMan111STEEL: Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping welding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification at all heights. (The laps and wastages shall not be measured separately).: Fifth Floor: (Level 07):Tonne98721.2298721.2213.0FalseNoneNoneFalseNoneFalse1283375.860
3924608151381NoneMan112STEEL: Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping welding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification at all heights. (The laps and wastages shall not be measured separately).: Sixth Floor: (Level 08):Tonne99708.4399708.4311.0FalseNoneNoneFalseNoneFalse1096792.730
3924609151381NoneMan113Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge (Note: Approval to be taken by submitting Shop drawings before executing the work) . CANOPY AREA: GROUND FLOOR:Kgs142.8142.811980.0FalseNoneNoneFalseNoneFalse1710744.00
3924610151381NoneMan114Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge (Note: Approval to be taken by submitting Shop drawings before executing the work). CANOPY AREA: Fourth Floor:Kgs148.6148.651330.0FalseNoneNoneFalseNoneFalse7627638.00
3924611151381NoneMan115Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings wooden frames with rawl plugs screws etc. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Weight of Grill 18 Kgs Sq.m)Kgs192.15192.15270.0FalseNoneNoneFalseNoneFalse51880.50
3924612151381NoneMan116MASONRY WORKS: Providing Size Stone masonry with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. Cement Mortar 1:6.Cum6708.456708.4515.0FalseNoneNoneFalseNoneFalse100626.750
3924613151381NoneMan117Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg m3 and minimum compressive strength of 4.00 N mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. with SOLID CONCRETE BLOCKS of Sizes 400 x 200 x 200mm: Basement Floor:Sqm1375.51375.5245.0FalseNoneNoneFalseNoneFalse336997.50
3924614151381NoneMan118Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg m3 and minimum compressive strength of 4.00 N mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. with SOLID CONCRETE BLOCKS of Sizes 400 x 200 x 200mm: Ground Floor: Level 02:Sqm1375.51375.51455.0FalseNoneNoneFalseNoneFalse2001352.50
3924615151381NoneMan119Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg m3 and minimum compressive strength of 4.00 N mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. with SOLID CONCRETE BLOCKS of Sizes 400 x 200 x 200mm: First Floor: Level 03:Sqm1389.261389.261295.0FalseNoneNoneFalseNoneFalse1799091.70
3924616151381NoneMan120Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg m3 and minimum compressive strength of 4.00 N mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. with SOLID CONCRETE BLOCKS of Sizes 400 x 200 x 200mm: Second Floor: Level 04:Sqm1403.151403.151435.0FalseNoneNoneFalseNoneFalse2013520.250
3924617151381NoneMan121Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg m3 and minimum compressive strength of 4.00 N mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. with SOLID CONCRETE BLOCKS of Sizes 400 x 200 x 200mm: Third Floor: Level 05:Sqm1417.181417.181360.0FalseNoneNoneFalseNoneFalse1927364.80
3924618151381NoneMan122Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg m3 and minimum compressive strength of 4.00 N mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. with SOLID CONCRETE BLOCKS of Sizes 400 x 200 x 200mm: Fourth Floor: Level 06:Sqm1431.351431.351035.0FalseNoneNoneFalseNoneFalse1481447.250
3924619151381NoneMan123Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg m3 and minimum compressive strength of 4.00 N mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. with SOLID CONCRETE BLOCKS of Sizes 400 x 200 x 200mm: Fifth Floor: Level 06:Sqm1445.661445.661850.0FalseNoneNoneFalseNoneFalse2674471.00
3924620151381NoneMan124Providing and Constructing Load Bearing Wall with SOLID CONCRETE BLOCKS having block density not less than 1800 Kg Cu.m having a minimum average compressive strength of 5.00 N Sq.mm confirming to IS 2185 (Part I):2005 and constructed with CM 1:4, as per IS 2572:2005 including cost of all materials labour charges, scaffolding, curing, hire charges of machineries, etc., complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. with SOLID CONCRETE BLOCKS of Sizes 400 x 150 x 200mm: Ground Floor:Sqm1292.551292.55805.0FalseNoneNoneFalseNoneFalse1040502.750
3924621151381NoneMan125Providing and Constructing Load Bearing Wall with SOLID CONCRETE BLOCKS having block density not less than 1800 Kg Cu.m having a minimum average compressive strength of 5.00 N Sq.mm confirming to IS 2185 (Part I):2005 and constructed with CM 1:4, as per IS 2572:2005 including cost of all materials labour charges, scaffolding, curing, hire charges of machineries, etc., complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. KBS No. 5.4 with SOLID CONCRETE BLOCKS of Sizes 400 x 150 x 200mm: First Floor:Sqm1305.481305.48410.0FalseNoneNoneFalseNoneFalse535246.80
3924622151381NoneMan126Providing and Constructing Load Bearing Wall with SOLID CONCRETE BLOCKS having block density not less than 1800 Kg Cu.m having a minimum average compressive strength of 5.00 N Sq.mm confirming to IS 2185 (Part I):2005 and constructed with CM 1:4, as per IS 2572:2005 including cost of all materials labour charges, scaffolding, curing, hire charges of machineries, etc., complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. KBS No. 5.4 with SOLID CONCRETE BLOCKS of Sizes 400 x 150 x 200mm: Second Floor:Sqm1318.531318.53485.0FalseNoneNoneFalseNoneFalse639487.050
3924623151381NoneMan127Providing and Constructing Load Bearing Wall with SOLID CONCRETE BLOCKS having block density not less than 1800 Kg Cu.m having a minimum average compressive strength of 5.00 N Sq.mm confirming to IS 2185 (Part I):2005 and constructed with CM 1:4, as per IS 2572:2005 including cost of all materials labour charges, scaffolding, curing, hire charges of machineries, etc., complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. KBS No. 5.4 with SOLID CONCRETE BLOCKS of Sizes 400 x 150 x 200mm: Third Floor:Sqm1331.721331.72710.0FalseNoneNoneFalseNoneFalse945521.20
3924624151381NoneMan128Providing and Constructing Load Bearing Wall with SOLID CONCRETE BLOCKS having block density not less than 1800 Kg Cu.m having a minimum average compressive strength of 5.00 N Sq.mm confirming to IS 2185 (Part I):2005 and constructed with CM 1:4, as per IS 2572:2005 including cost of all materials labour charges, scaffolding, curing, hire charges of machineries, etc., complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. KBS No. 5.4 with SOLID CONCRETE BLOCKS of Sizes 400 x 150 x 200mm: Fourth Floor:Sqm1345.041345.04710.0FalseNoneNoneFalseNoneFalse954978.40
3924625151381NoneMan129Providing and Constructing Load Bearing Wall with SOLID CONCRETE BLOCKS having block density not less than 1800 Kg Cu.m having a minimum average compressive strength of 5.00 N Sq.mm confirming to IS 2185 (Part I):2005 and constructed with CM 1:4, as per IS 2572:2005 including cost of all materials labour charges, scaffolding, curing, hire charges of machineries, etc., complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. KBS No. 5.4 with SOLID CONCRETE BLOCKS of Sizes 400 x 150 x 200mm: Fifth Floor:Sqm1358.491358.49710.0FalseNoneNoneFalseNoneFalse964527.90
3924626151381NoneMan130Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg m3 and minimum compressive strength of 4.00 N mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer incharge of the works.: Ground Floor:Sqm1159.21159.2890.0FalseNoneNoneFalseNoneFalse1031688.00
3924627151381NoneMan131Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg m3 and minimum compressive strength of 4.00 N mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer incharge of the works.: First Floor:Sqm1170.791170.79395.0FalseNoneNoneFalseNoneFalse462462.050
3924628151381NoneMan132Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg m3 and minimum compressive strength of 4.00 N mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer incharge of the works.: Second Floor:Sqm1182.51182.51515.0FalseNoneNoneFalseNoneFalse1791487.50
3924629151381NoneMan133Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg m3 and minimum compressive strength of 4.00 N mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer incharge of the works.: Third Floor:Sqm1194.331194.331515.0FalseNoneNoneFalseNoneFalse1809409.950
3924630151381NoneMan134Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg m3 and minimum compressive strength of 4.00 N mm2 conforming to IS 2185 (Part I) 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer incharge of the works.: Fourth Floor:Sqm1206.271206.271515.0FalseNoneNoneFalseNoneFalse1827499.050
3924631151381NoneMan135PLASTERING: Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Ceiling Plastering) : Lower Basement 01:Sqm309.75309.753694.0FalseNoneNoneFalseNoneFalse1144216.50
3924632151381NoneMan136PLASTERING: Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Ceiling Plastering) : Ground Floor:Sqm309.75309.753277.0FalseNoneNoneFalseNoneFalse1015050.750
3924633151381NoneMan137PLASTERING: Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Ceiling Plastering): First Floor:Sqm312.85312.854090.0FalseNoneNoneFalseNoneFalse1279556.50
3924634151381NoneMan138PLASTERING: Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Ceiling Plastering): Second Floor:Sqm315.98315.983395.0FalseNoneNoneFalseNoneFalse1072752.10
3924635151381NoneMan139PLASTERING: Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Ceiling Plastering): Third Floor:Sqm319.14319.144080.0FalseNoneNoneFalseNoneFalse1302091.20
3924636151381NoneMan140PLASTERING: Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Ceiling Plastering): Fourth Floor:Sqm322.33322.331970.0FalseNoneNoneFalseNoneFalse634990.10
3924637151381NoneMan141PLASTERING: Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Ceiling Plastering): Fifth Floor:Sqm325.55325.55780.0FalseNoneNoneFalseNoneFalse253929.00
3924638151381NoneMan1421. Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 Fine sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Water Proof Plastering Ceilings and Walls) 2. Extra for providing and mixing water proofing materials in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. [NOTE: Dosage at 1Kgs per Bag of Cement]: LOWER BASEMENT 01Sqm396.93396.932029.0FalseNoneNoneFalseNoneFalse805370.970
3924639151381NoneMan1431. Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 Fine sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Water Proof Plastering Ceilings and Walls) 2. Extra for providing and mixing water proofing materials in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. [NOTE: Dosage at 1Kgs per Bag of Cement]: GROUND FLOORSqm396.93396.93134.0FalseNoneNoneFalseNoneFalse53188.620
3924640151381NoneMan144Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Internal Plastering)Sqm366.45366.45140.0FalseNoneNoneFalseNoneFalse51303.00
3924641151381NoneMan1451. Providing 15mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.. (Water Proof Plastering Walls + Floor of Lift and Toilets) 2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. [NOTE: Dosage at 1Kgs per Bag of Cement].: LOWER BASEMENT 01Sqm376.4376.4415.0FalseNoneNoneFalseNoneFalse156206.00
3924642151381NoneMan1461. Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 Fine sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Ceiling Plastering): BASEMENT FLOOR:Sqm384.3384.320.0FalseNoneNoneFalseNoneFalse7686.00
3924643151381NoneMan1471. Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 Fine sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Ceiling Plastering): GROUND FLOOR:Sqm384.3384.323.0FalseNoneNoneFalseNoneFalse8838.90
3924644151381NoneMan1481. Providing 15mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.. (Water Proof Plastering Walls + Floor of Lift and Toilets) 2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. [NOTE: Dosage at 1Kgs per Bag of Cement].: Ground Floor:Sqm376.4376.4170.0FalseNoneNoneFalseNoneFalse63988.00
3924645151381NoneMan1491. Providing 15mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.. (Water Proof Plastering Walls + Floor of Lift and Toilets) 2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. [NOTE: Dosage at 1Kgs per Bag of Cement].: First Floor:Sqm380.16380.16165.0FalseNoneNoneFalseNoneFalse62726.40
3924646151381NoneMan1501. Providing 15mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.. (Water Proof Plastering Walls + Floor of Lift and Toilets) 2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. [NOTE: Dosage at 1Kgs per Bag of Cement].: Second Floor:Sqm383.96383.96185.0FalseNoneNoneFalseNoneFalse71032.60
3924647151381NoneMan1511. Providing 15mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.. (Water Proof Plastering Walls + Floor of Lift and Toilets) 2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. [NOTE: Dosage at 1Kgs per Bag of Cement].: Third Floor:Sqm387.8387.8165.0FalseNoneNoneFalseNoneFalse63987.00
3924648151381NoneMan1521. Providing 15mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.. (Water Proof Plastering Walls + Floor of Lift and Toilets) 2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. [NOTE: Dosage at 1Kgs per Bag of Cement].: Fourth Floor:Sqm391.68391.68195.0FalseNoneNoneFalseNoneFalse76377.60
3924649151381NoneMan153Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Internal Plastering): LOWER BASEMENT 01Sqm366.45366.451475.0FalseNoneNoneFalseNoneFalse540513.750
3924650151381NoneMan154Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Internal Plastering): Ground Floor:Sqm366.45366.453438.0FalseNoneNoneFalseNoneFalse1259855.10
3924651151381NoneMan155Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Internal Plastering): FIRST FLOOR:Sqm370.11370.113075.0FalseNoneNoneFalseNoneFalse1138088.250
3924652151381NoneMan156Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Internal Plastering): SECOND FLOOR:Sqm373.81373.812815.0FalseNoneNoneFalseNoneFalse1052275.150
3924653151381NoneMan157Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Internal Plastering): THIRD FLOOR:Sqm377.55377.552740.0FalseNoneNoneFalseNoneFalse1034487.00
3924654151381NoneMan158Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Internal Plastering): Fourth FLOOR:Sqm381.33381.332000.0FalseNoneNoneFalseNoneFalse762660.00
3924655151381NoneMan159Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Internal Plastering): Fifth FLOOR:Sqm385.14385.141510.0FalseNoneNoneFalseNoneFalse581561.40
3924656151381NoneMan160Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. Rough Cement Plastering.: Lower Basement 01Sqm309.75309.7585.0FalseNoneNoneFalseNoneFalse26328.750
3924657151381NoneMan161Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. Rough Cement Plastering.: Ground Floor:Sqm309.75309.75455.0FalseNoneNoneFalseNoneFalse140936.250
3924658151381NoneMan162Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. Rough Cement Plastering.: FIRST FLOOR:Sqm312.85312.85405.0FalseNoneNoneFalseNoneFalse126704.250
3924659151381NoneMan163Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. Rough Cement Plastering.: SECOND FLOOR:Sqm315.98315.98575.0FalseNoneNoneFalseNoneFalse181688.50
3924660151381NoneMan164Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. Rough Cement Plastering.: THIRD FLOOR:Sqm319.14319.14405.0FalseNoneNoneFalseNoneFalse129251.70
3924661151381NoneMan165Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. Rough Cement Plastering.: FOURTH FLOOR:Sqm322.33322.33430.0FalseNoneNoneFalseNoneFalse138601.90
3924662151381NoneMan166Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. Rough Cement Plastering.: FIFTH Floor:Sqm325.55325.5575.0FalseNoneNoneFalseNoneFalse24416.250
3924663151381NoneMan1671. Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.. (External Plastering Water Proof Plastering) Walls Including CONCRETE Members and Stone Masonry) (External Plastering) 2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. [NOTE: Dosage at 1Kgs per Bag of Cement] (External Plastering Water Proof Plastering) Walls (Including CONCRETE Members and Stone Masonry): 1. Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.. (External Plastering Water Proof Plastering) Walls Including CONCRETE Members and Stone Masonry) (External Plastering) 2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. [NOTE: Dosage at 1Kgs per Bag of Cement] (External Plastering Water Proof Plastering) Walls (Including CONCRETE Members and Stone Masonry): Sub Structure:Sqm415.2415.21330.0FalseNoneNoneFalseNoneFalse552216.00
3924664151381NoneMan1681. Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.. (External Plastering Water Proof Plastering) Walls Including CONCRETE Members and Stone Masonry) (External Plastering) 2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. [NOTE: Dosage at 1Kgs per Bag of Cement] (External Plastering Water Proof Plastering) Walls (Including CONCRETE Members and Stone Masonry): LOWER BASEMENT 01:Sqm415.2415.21410.0FalseNoneNoneFalseNoneFalse585432.00
3924665151381NoneMan169Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. (External Surface, Lift Shaft and Duct Plastering): Lower Basement 01:Sqm404.25404.25210.0FalseNoneNoneFalseNoneFalse84892.50
3924666151381NoneMan170Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. (External Surface, Lift Shaft and Duct Plastering): Ground Floor:Sqm404.25404.251215.0FalseNoneNoneFalseNoneFalse491163.750
3924667151381NoneMan171Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. (External Surface, Lift Shaft and Duct Plastering): First Floor:Sqm408.29408.291205.0FalseNoneNoneFalseNoneFalse491989.450
3924668151381NoneMan172Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. (External Surface, Lift Shaft and Duct Plastering): SECOND FLOOR:Sqm412.37412.37975.0FalseNoneNoneFalseNoneFalse402060.750
3924669151381NoneMan173Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. (External Surface, Lift Shaft and Duct Plastering): THIRD FLOOR:Sqm416.49416.49915.0FalseNoneNoneFalseNoneFalse381088.350
3924670151381NoneMan174Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. (External Surface, Lift Shaft and Duct Plastering): FOURTH FLOOR:Sqm420.65420.65915.0FalseNoneNoneFalseNoneFalse384894.750
3924671151381NoneMan175Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. (External Surface, Lift Shaft and Duct Plastering): FIFTH FLOOR:Sqm424.86424.86915.0FalseNoneNoneFalseNoneFalse388746.90
3924672151381NoneMan176Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof including cost of material, labour, scaffolding etc as per specifications and as per directions of the EngineerinCharge at all levels.Sqm64.0164.013280.0FalseNoneNoneFalseNoneFalse209952.80
3924673151381NoneMan1771. Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Water Proof Plastering Floor and Ceiling) 2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. [NOTE: Dosage at 1Kgs per Bag of Cement] : Sixth Floor:Sqm421.35421.35330.0FalseNoneNoneFalseNoneFalse139045.50
3924674151381NoneMan178WATER PROOFING: Providing and laying water proofing treatment to the Rafts, Below grade slab, Lift pits, water retaining structures with fully bonded High Density Polyethlene Membrane (HDPE) of 1.2mm composite thickness and having tensile strength of 25 MPa (as per ASTM D 412), elongation of 500percent (as per ASTM D 412), puncture resistance of 1000N (as per ASTM E 154), peel adhesion to concrete 1200N m (as per ASTM D 903), hydrostatic head resistance 70m (as per ASTM D 5385). The system should be fully bonded to the RCC thereby conforming to IS 16471:2017 requirements of UG waterproofing structures. The membrane should be minimum 2.4m wide to reduce the number of joints with minimum 75mm factory made selvedge’s and comprising of an HDPE layer and a pressure sensitive adhesive layer which is covered by a weather proof protective and trafficable granular layer to protect selfadhesive polymer layer, etc, including surface preparation completely as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge. Sub Structure:Sqm635.25635.251810.0FalseNoneNoneFalseNoneFalse1149802.50
3924675151381NoneMan179WATER PROOFING: Providing and laying water proofing treatment to the Retaining wall area with PU Elastomeric Single component liquid applied, cold applied, moisture cured high tensile elastomeric PU waterproofing membrane having elongation of more than 400percent and having solid content of above 90percent at 1.6kg per m2 in 2 coats to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g m2. The cost is inclusive of surface preparation, crack filling, repair of loose mortar etc. completely as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge. Retaining wall: Sub Structure:Sqm932.4932.4545.0FalseNoneNoneFalseNoneFalse508158.00
3924676151381NoneMan180WATER PROOFING: Providing and laying water proofing treatment to the Retaining wall area with PU Elastomeric Single component liquid applied, cold applied, moisture cured high tensile elastomeric PU waterproofing membrane having elongation of more than 400percent and having solid content of above 90percent at 1.6kg per m2 in 2 coats to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g m2. The cost is inclusive of surface preparation, crack filling, repair of loose mortar etc. completely as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge. Retaining wall: Lower Basement 01: (Level 01):Sqm932.4932.41684.0FalseNoneNoneFalseNoneFalse1570161.60
3924677151381NoneMan181TERRACE WATER PROOFING: Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace Chajjas Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percent and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g per m2 and protection with 120gsm Geotextile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely at all levels as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge.: Ground Floor:Sqm857.85857.85506.0FalseNoneNoneFalseNoneFalse434072.10
3924678151381NoneMan182TERRACE WATER PROOFING: Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace Chajjas Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percent and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g per m2 and protection with 120gsm Geotextile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely at all levels as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge.: Second Floor:Sqm875.09875.09445.0FalseNoneNoneFalseNoneFalse389415.050
3924679151381NoneMan183TERRACE WATER PROOFING: Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace Chajjas Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percent and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g per m2 and protection with 120gsm Geotextile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely at all levels as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge.: Terrace Floor:Sqm910.63910.631860.0FalseNoneNoneFalseNoneFalse1693771.80
3924680151381NoneMan184TERRACE WATER PROOFING: Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace Chajjas Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percent and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g per m2 and protection with 120gsm Geotextile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely at all levels as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge.: Terrace Floor: Head RoomSqm919.74919.74235.0FalseNoneNoneFalseNoneFalse216138.90
3924681151381NoneMan185Water retaining Structures: Retaining Structures: Providing and laying water proofing treatment to the Retaining wall area with PU Elastomeric Single component liquid applied, cold applied, moisture cured high tensile elastomeric PU waterproofing membrane having elongation of more than 400percent and having solid content of above 90percent at 1.6kg per m2 in 2 coats to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g m2. The cost is inclusive of surface preparation, crack filling, repair of loose mortar etc. completely as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge. WALL : LOWER BASEMENT 01Sqm932.4932.450.0FalseNoneNoneFalseNoneFalse46620.00
3924682151381NoneMan186FOR TOILETS SUNK PORTIONS: Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace Chajjas Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percent and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g per m2 and protection with 120gsm Geotextile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge. Sunken portion of WC:Bathroom: Ground Floor:Sqm857.85857.85170.0FalseNoneNoneFalseNoneFalse145834.50
3924683151381NoneMan187FOR TOILETS SUNK PORTIONS: Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace Chajjas Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percent and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g per m2 and protection with 120gsm Geotextile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge. Sunken portion of WC:Bathroom: First Floor:Sqm866.43866.43105.0FalseNoneNoneFalseNoneFalse90975.150
3924684151381NoneMan188FOR TOILETS SUNK PORTIONS: Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace Chajjas Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percent and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g per m2 and protection with 120gsm Geotextile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge. Sunken portion of WC:Bathroom: Second Floor:Sqm875.09875.09180.0FalseNoneNoneFalseNoneFalse157516.20
3924685151381NoneMan189FOR TOILETS SUNK PORTIONS: Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace Chajjas Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percent and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g per m2 and protection with 120gsm Geotextile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge. Sunken portion of WC:Bathroom: Third Floor:Sqm883.84883.84180.0FalseNoneNoneFalseNoneFalse159091.20
3924686151381NoneMan190FOR TOILETS SUNK PORTIONS: Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace Chajjas Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400percent and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats at 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer at150 g per m2 and protection with 120gsm Geotextile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification and with a 10 years warranty on product and work from certified manufacturers as per the direction of the Engineer In charge. Sunken portion of WC:Bathroom: Fourth Floor:Sqm892.68892.68180.0FalseNoneNoneFalseNoneFalse160682.40
3924687151381NoneMan191Swellable rapid expansion water proofing for construction joints in all types of concrete works composite works: Providing and fixing PVC water stopper of suitable type of 230 mm width and 5 mm thickness for construction joints as per detailed technical specifications and as directed by Engineerin charge: Sub Structure Floor:: UP TO Foundation LVLRmtr325.5325.51245.0FalseNoneNoneFalseNoneFalse405247.50
3924688151381NoneMan192Swellable rapid expansion water proofing for construction joints in all types of concrete works composite works: Providing and fixing PVC water stopper of suitable type of 230 mm width and 5 mm thickness for construction joints as per detailed technical specifications and as directed by Engineerin charge: Lower Basement FLOOR: Level 01:Rmtr325.5325.51800.0FalseNoneNoneFalseNoneFalse585900.00
3924689151381NoneMan193Swellable rapid expansion water proofing for construction joints in all types of concrete works composite works: Providing and fixing PVC water stopper of suitable type of 230 mm width and 5 mm thickness for construction joints as per detailed technical specifications and as directed by Engineerin charge: GROUND FLOOR: Level 02:Rmtr325.5325.550.0FalseNoneNoneFalseNoneFalse16275.00
3924690151381NoneMan194Swellable rapid expansion water proofing for construction joints in all types of concrete works composite works: Providing and fixing PVC water stopper of suitable type of 230 mm width and 5 mm thickness for construction joints as per detailed technical specifications and as directed by Engineerin charge: First FLOOR: Level 03:Rmtr328.76328.7650.0FalseNoneNoneFalseNoneFalse16438.00
3924691151381NoneMan195Swellable rapid expansion water proofing for construction joints in all types of concrete works composite works: Providing and fixing PVC water stopper of suitable type of 230 mm width and 5 mm thickness for construction joints as per detailed technical specifications and as directed by Engineerin charge: Second FLOOR: Level 04:Rmtr332.05332.0550.0FalseNoneNoneFalseNoneFalse16602.50
3924692151381NoneMan196Swellable rapid expansion water proofing for construction joints in all types of concrete works composite works: Providing and fixing PVC water stopper of suitable type of 230 mm width and 5 mm thickness for construction joints as per detailed technical specifications and as directed by Engineerin charge: Third FLOOR: Level 05:Rmtr335.37335.3750.0FalseNoneNoneFalseNoneFalse16768.50
3924693151381NoneMan197Swellable rapid expansion water proofing for construction joints in all types of concrete works composite works: Providing and fixing PVC water stopper of suitable type of 230 mm width and 5 mm thickness for construction joints as per detailed technical specifications and as directed by Engineerin charge: Fourth FLOOR: Level 05:Rmtr338.72338.7265.0FalseNoneNoneFalseNoneFalse22016.80
3924694151381NoneMan198Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment ) including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. suitable plaster mesh 150mm wide.: Lower Basement 01Rmtr39.939.9458.0FalseNoneNoneFalseNoneFalse18274.20
3924695151381NoneMan199Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment ) including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. suitable plaster mesh 150mm wide.: Ground FloorRmtr39.939.9680.0FalseNoneNoneFalseNoneFalse27132.00
3924696151381NoneMan200Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment ) including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. suitable plaster mesh 150mm wide.: First FloorRmtr40.340.3630.0FalseNoneNoneFalseNoneFalse25389.00
3924697151381NoneMan201Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment ) including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. suitable plaster mesh 150mm wide.: Second FloorRmtr40.740.7755.0FalseNoneNoneFalseNoneFalse30728.50
3924698151381NoneMan202Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment ) including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. suitable plaster mesh 150mm wide.: Third FloorRmtr41.1141.11755.0FalseNoneNoneFalseNoneFalse31038.050
3924699151381NoneMan203Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment ) including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. suitable plaster mesh 150mm wide.: Fourth FloorRmtr41.5241.52715.0FalseNoneNoneFalseNoneFalse29686.80
3924700151381NoneMan204Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment ) including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. suitable plaster mesh 150mm wide.: Fifth FloorRmtr41.9441.94555.0FalseNoneNoneFalseNoneFalse23276.70
3924701151381NoneMan205FLOORING WORKS: Providing and laying Cement concrete flooring 100 mm thick with 20mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete. 100mm Thick Ground Floor: (Level 02):Sqm1183.881183.88540.0FalseNoneNoneFalseNoneFalse639295.20
3924702151381NoneMan206FLOORING WORKS: Providing and laying Cement concrete flooring 75 mm thick with 20mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete. 75mm ThickSqm473.6473.6219.0FalseNoneNoneFalseNoneFalse103718.40
3924703151381NoneMan207Vaccum dewatering with vaccum pump and suction mat and compaction with skin floater clubbed with floating disc including cost of generator, HOM of machinery, Screed Vibratory, Power Floater, blade and disc etc., with all lead and lift. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : (i). Lower Basement 01: (Level 01):Sqm71.471.42010.0FalseNoneNoneFalseNoneFalse143514.00
3924704151381NoneMan208Vaccum dewatering with vaccum pump and suction mat and compaction with skin floater clubbed with floating disc including cost of generator, HOM of machinery, Screed Vibratory, Power Floater, blade and disc etc., with all lead and lift. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : (ii). Ground Floor: (Level 02):Sqm71.471.4400.0FalseNoneNoneFalseNoneFalse28560.00
3924705151381NoneMan209Providing groove cutting for width of 5mm to 10mm and depth 80mm 100mm including cost of cutting machine, generator and HOM, including cost of blade,coolant etc., including cleaning of groove and providing sand and hot bitumen fillars, and filler metal etc., including cost of conveyance of all materials, labour, lead and lift charges and all other incidental charges as per drawing and as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. for concrete pavement : (i). Lower Basement 01: (Level 01):Rmtr141.75141.75750.0FalseNoneNoneFalseNoneFalse106312.50
3924706151381NoneMan210Providing groove cutting for width of 5mm to 10mm and depth 80mm 100mm including cost of cutting machine, generator and HOM, including cost of blade,coolant etc., including cleaning of groove and providing sand and hot bitumen fillars, and filler metal etc., including cost of conveyance of all materials, labour, lead and lift charges and all other incidental charges as per drawing and as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. for concrete pavement : (ii). Ground Floor: (Level 02):Rmtr141.75141.75175.0FalseNoneNoneFalseNoneFalse24806.250
3924707151381NoneMan211Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Average 100mm Thick. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin Charge.: Lower Basement 01: (Level 01):Sqm1126.231126.232010.0FalseNoneNoneFalseNoneFalse2263722.30
3924708151381NoneMan212Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates TERRACE SCREED and LOWER BASEMENT FLOOR. Average 100mm Thick. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin Charge.: Ground Floor:Sqm1126.231126.23140.0FalseNoneNoneFalseNoneFalse157672.20
3924709151381NoneMan213Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Average 100mm Thick. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin Charge.: SECOND Floor:Sqm1148.861148.86445.0FalseNoneNoneFalseNoneFalse511242.70
3924710151381NoneMan214Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Average 100mm Thick. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin Charge.: THIRD Floor:Sqm1160.351160.35445.0FalseNoneNoneFalseNoneFalse516355.750
3924711151381NoneMan215Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Average 100mm Thick. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin Charge.: Terrace Floor:Sqm1183.671183.671860.0FalseNoneNoneFalseNoneFalse2201626.20
3924712151381NoneMan216Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Average 100mm Thick. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineerin Charge.: Terrace Floor: Head RoomSqm1195.511195.51235.0FalseNoneNoneFalseNoneFalse280944.850
3924713151381NoneMan217Providing and fixing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement: 4 coarse sand) mixed with 2percent integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete. (Basic Cost of Pressed Clay Tiles 20mm thick 250 x 250mm Size Rs. 9030 for 1000 Nos.): Ground Floor:Sqm593.25593.25140.0FalseNoneNoneFalseNoneFalse83055.00
3924714151381NoneMan218Providing and fixing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement: 4 coarse sand) mixed with 2percent integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete. (Basic Cost of Pressed Clay Tiles 20mm thick 250 x 250mm Size Rs. 9030 for 1000 Nos.): SECOND Floor:Sqm605.17605.17445.0FalseNoneNoneFalseNoneFalse269300.650
3924715151381NoneMan219Providing and fixing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement: 4 coarse sand) mixed with 2percent integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete. (Basic Cost of Pressed Clay Tiles 20mm thick 250 x 250mm Size Rs. 9030 for 1000 Nos.): THIRD Floor:Sqm611.22611.22445.0FalseNoneNoneFalseNoneFalse271992.90
3924716151381NoneMan220Providing and fixing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement: 4 coarse sand) mixed with 2percent integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete. (Basic Cost of Pressed Clay Tiles 20mm thick 250 x 250mm Size Rs. 9030 for 1000 Nos.): Terrace Floor:Sqm623.5623.51860.0FalseNoneNoneFalseNoneFalse1159710.00
3924717151381NoneMan221Providing and fixing and laying pressed clay tiles (as per approved pattern 20 mm nominal thickness of approved size) on roofs jointed with cement mortar 1:4 (1 cement: 4 coarse sand) mixed with 2percent integral water proofing compound, laid over a bed of 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) and finished neat complete. (Basic Cost of Pressed Clay Tiles 20mm thick 250 x 250mm Size Rs. 9030 for 1000 Nos.): Terrace Floor: Head RoomSqm629.74629.74235.0FalseNoneNoneFalseNoneFalse147988.90
3924718151381NoneMan222ANTI SKID VITRIFIED TILES: Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08percent and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry at 3.3 kg m2 including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. ANTI SKID VITRIFIED TILES 600mm x 600mm: Ground Floor:Sqm1202.251202.25110.0FalseNoneNoneFalseNoneFalse132247.50
3924719151381NoneMan223ANTI SKID VITRIFIED TILES: Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08percent and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry at 3.3 kg m2 including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. ANTI SKID VITRIFIED TILES 600mm x 600mm: First Floor:Sqm1214.271214.27110.0FalseNoneNoneFalseNoneFalse133569.70
3924720151381NoneMan224ANTI SKID VITRIFIED TILES: Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08percent and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry at 3.3 kg m2 including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. ANTI SKID VITRIFIED TILES 600mm x 600mm: Second Floor:Sqm1226.411226.41125.0FalseNoneNoneFalseNoneFalse153301.250
3924721151381NoneMan225ANTI SKID VITRIFIED TILES: Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08percent and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry at 3.3 kg m2 including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. ANTI SKID VITRIFIED TILES 600mm x 600mm: Third Floor:Sqm1238.671238.67110.0FalseNoneNoneFalseNoneFalse136253.70
3924722151381NoneMan226ANTI SKID VITRIFIED TILES: Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08percent and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry at 3.3 kg m2 including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. ANTI SKID VITRIFIED TILES 600mm x 600mm: Fourth Floor:Sqm1251.061251.06190.0FalseNoneNoneFalseNoneFalse237701.40
3924723151381NoneMan227Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Tiles 300 x 600. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Ground Floor:Sqm1161.31161.3320.0FalseNoneNoneFalseNoneFalse371616.00
3924724151381NoneMan228Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Tiles 300 x 600. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : FIRST FLOOR:Sqm1172.911172.91320.0FalseNoneNoneFalseNoneFalse375331.20
3924725151381NoneMan229Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Tiles 300 x 600. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : SECOND FLOOR:Sqm1184.641184.64490.0FalseNoneNoneFalseNoneFalse580473.60
3924726151381NoneMan230Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Tiles 300 x 600. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : THIRD FLOOR:Sqm1196.491196.49320.0FalseNoneNoneFalseNoneFalse382876.80
3924727151381NoneMan231Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Tiles 300 x 600. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : FOURTH FLOOR:Sqm1208.451208.45355.0FalseNoneNoneFalseNoneFalse428999.750
3924728151381NoneMan232Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. VITRIFIED Tiles 300 x 450. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: Lower Basement 01Sqm1161.31161.380.0FalseNoneNoneFalseNoneFalse92904.00
3924729151381NoneMan233Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. VITRIFIED Tiles 300 x 450. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: Ground Floor:Sqm1161.31161.375.0FalseNoneNoneFalseNoneFalse87097.50
3924730151381NoneMan234Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. VITRIFIED Tiles 300 x 450. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: FIRST FLOOR:Sqm1172.911172.9180.0FalseNoneNoneFalseNoneFalse93832.80
3924731151381NoneMan235Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. VITRIFIED Tiles 300 x 450. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: SECOND FLOOR:Sqm1184.641184.6480.0FalseNoneNoneFalseNoneFalse94771.20
3924732151381NoneMan236Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. VITRIFIED Tiles 300 x 450. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: THIRD FLOOR:Sqm1196.491196.4980.0FalseNoneNoneFalseNoneFalse95719.20
3924733151381NoneMan237Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer inCharge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry at 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. VITRIFIED Tiles 300 x 450. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: FOURTH FLOOR:Sqm1208.451208.4580.0FalseNoneNoneFalseNoneFalse96676.00
3924734151381NoneMan238Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.: Lower Basement 01:Sqm5594.45594.4120.0FalseNoneNoneFalseNoneFalse671328.00
3924735151381NoneMan239Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.: Ground Floor:Sqm5594.45594.4160.0FalseNoneNoneFalseNoneFalse895104.00
3924736151381NoneMan240Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.: FIRST FLOORSqm5650.345650.3485.0FalseNoneNoneFalseNoneFalse480278.90
3924737151381NoneMan241Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.: SECOND FLOORSqm5706.845706.8480.0FalseNoneNoneFalseNoneFalse456547.20
3924738151381NoneMan242Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.: THIRD FLOORSqm5763.915763.9180.0FalseNoneNoneFalseNoneFalse461112.80
3924739151381NoneMan243Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.: FOURTH FLOORSqm5821.555821.5590.0FalseNoneNoneFalseNoneFalse523939.50
3924740151381NoneMan244Providing and laying Flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineerinCharge : ** Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.: GROUND FLOOR:Sqm2589.32589.3190.0FalseNoneNoneFalseNoneFalse491967.00
3924741151381NoneMan245Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08percent and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry at 3.3 kg m2 including grouting the joints with white cement and matching pigments etc., complete. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Size of the Tiles : 600 x 600: GROUND FLOOR:Sqm1202.251202.251518.0FalseNoneNoneFalseNoneFalse1825015.50
3924742151381NoneMan246Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08percent and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry at 3.3 kg m2 including grouting the joints with white cement and matching pigments etc., complete. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Size of the Tiles : 600 x 600: FIRST FLOORSqm1214.271214.271450.0FalseNoneNoneFalseNoneFalse1760691.50
3924743151381NoneMan247Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08percent and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry at 3.3 kg m2 including grouting the joints with white cement and matching pigments etc., complete. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Size of the Tiles : 600 x 600: SECOND FLOOR:Sqm1226.411226.411690.0FalseNoneNoneFalseNoneFalse2072632.90
3924744151381NoneMan248Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08percent and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry at 3.3 kg m2 including grouting the joints with white cement and matching pigments etc., complete. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Size of the Tiles : 600 x 600: THIRD FLOORSqm1238.671238.67935.0FalseNoneNoneFalseNoneFalse1158156.450
3924745151381NoneMan249Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08percent and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry at 3.3 kg m2 including grouting the joints with white cement and matching pigments etc., complete. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Size of the Tiles : 600 x 600: FOURTH FLOORSqm1251.061251.06385.0FalseNoneNoneFalseNoneFalse481658.10
3924746151381NoneMan250Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineerinCharge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.: Lower Basement 01:Sqm2994.62994.650.0FalseNoneNoneFalseNoneFalse149730.00
3924747151381NoneMan251Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineerinCharge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.: Ground Floor:Sqm2994.62994.6375.0FalseNoneNoneFalseNoneFalse1122975.00
3924748151381NoneMan252Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineerinCharge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.: First Floor:Sqm3024.553024.55280.0FalseNoneNoneFalseNoneFalse846874.00
3924749151381NoneMan253Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineerinCharge. Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.: Second Floor:Sqm3054.83054.8660.0FalseNoneNoneFalseNoneFalse2016168.00
3924750151381NoneMan254Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineerinCharge. Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.: THIRD Floor:Sqm3085.353085.35680.0FalseNoneNoneFalseNoneFalse2098038.00
3924751151381NoneMan255Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the EngineerinCharge. Polished Granite stone slab Black, Cat Eye, River Pink or equivalent.: Fourth Floor:Sqm3116.23116.255.0FalseNoneNoneFalseNoneFalse171391.00
3924752151381NoneMan256Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. LIFT PORTION: Lower Basement 01Sqm3787.353787.3525.0FalseNoneNoneFalseNoneFalse94683.750
3924753151381NoneMan257Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. LIFT PORTION: Ground Floor:Sqm3787.353787.3525.0FalseNoneNoneFalseNoneFalse94683.750
3924754151381NoneMan258Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. LIFT PORTION: FIRST FLOOR:Sqm3825.223825.2225.0FalseNoneNoneFalseNoneFalse95630.50
3924755151381NoneMan259Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. LIFT PORTION: SECOND FLOOR:Sqm3863.473863.4725.0FalseNoneNoneFalseNoneFalse96586.750
3924756151381NoneMan260Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. LIFT PORTION: THIRD FLOOR:Sqm3902.13902.125.0FalseNoneNoneFalseNoneFalse97552.50
3924757151381NoneMan261Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. LIFT PORTION: Fourth Floor:Sqm3941.123941.1225.0FalseNoneNoneFalseNoneFalse98528.00
3924758151381NoneMan262Providing and fixing of wall cladding using 20mm thick gang saw water cut Shiva gold granite, grey granite in CM 1:3 (1 cement : 3 coarse sand) proportion cut to required shape, pattern with paper joints, finished with cement mortal using white cement and colour pigments to match the colour of slab making through jointing with sealant, making holes 25mmx12mm grooves in joints including cost of all materials, mortar, labour, curing etc., complete. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. FRONT ENTRY PORTION : Ground Floor:Sqm3526.953526.95120.0FalseNoneNoneFalseNoneFalse423234.00
3924759151381NoneMan263Supplying, fabricating and fixing of Stainless steel cladding for walls using 304 grade Stainless steel 16 guage sheet wall cladding of thickness over the frame made out of 50x50mmx3mm thickness anodized aluminium frame work at an equal distance of 2 ft vertifically fixed to the wall using 100mm screws, guttas, anchor bolts and fastners with all necessary bending and cutting as per the desing and site condition. The frame work finally to be finished with 12mm BWP plywood to receive the SS sheet on it uniformly. Including cost of all materials, mortar, labour, curing etc., complete as per specification. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Lower Basement 01Sqm13097.213097.25.0FalseNoneNoneFalseNoneFalse65486.00
3924760151381NoneMan264Supplying, fabricating and fixing of Stainless steel cladding for walls using 304 grade Stainless steel 16 guage sheet wall cladding of thickness over the frame made out of 50x50mmx3mm thickness anodized aluminium frame work at an equal distance of 2 ft vertifically fixed to the wall using 100mm screws, guttas, anchor bolts and fastners with all necessary bending and cutting as per the desing and site condition. The frame work finally to be finished with 12mm BWP plywood to receive the SS sheet on it uniformly. Including cost of all materials, mortar, labour, curing etc., complete as per specification. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Ground Floor:Sqm12967.512967.55.0FalseNoneNoneFalseNoneFalse64837.50
3924761151381NoneMan265Supplying, fabricating and fixing of Stainless steel cladding for walls using 304 grade Stainless steel 16 guage sheet wall cladding of thickness over the frame made out of 50x50mmx3mm thickness anodized aluminium frame work at an equal distance of 2 ft vertifically fixed to the wall using 100mm screws, guttas, anchor bolts and fastners with all necessary bending and cutting as per the desing and site condition. The frame work finally to be finished with 12mm BWP plywood to receive the SS sheet on it uniformly. Including cost of all materials, mortar, labour, curing etc., complete as per specification. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : FIRST FLOOR:Sqm13097.213097.25.0FalseNoneNoneFalseNoneFalse65486.00
3924762151381NoneMan266Supplying, fabricating and fixing of Stainless steel cladding for walls using 304 grade Stainless steel 16 guage sheet wall cladding of thickness over the frame made out of 50x50mmx3mm thickness anodized aluminium frame work at an equal distance of 2 ft vertifically fixed to the wall using 100mm screws, guttas, anchor bolts and fastners with all necessary bending and cutting as per the desing and site condition. The frame work finally to be finished with 12mm BWP plywood to receive the SS sheet on it uniformly. Including cost of all materials, mortar, labour, curing etc., complete as per specification. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : SECOND FLOOR:Sqm13226.913226.95.0FalseNoneNoneFalseNoneFalse66134.50
3924763151381NoneMan267Supplying, fabricating and fixing of Stainless steel cladding for walls using 304 grade Stainless steel 16 guage sheet wall cladding of thickness over the frame made out of 50x50mmx3mm thickness anodized aluminium frame work at an equal distance of 2 ft vertifically fixed to the wall using 100mm screws, guttas, anchor bolts and fastners with all necessary bending and cutting as per the desing and site condition. The frame work finally to be finished with 12mm BWP plywood to receive the SS sheet on it uniformly. Including cost of all materials, mortar, labour, curing etc., complete as per specification. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : THIRD FLOOR:Sqm13356.613356.65.0FalseNoneNoneFalseNoneFalse66783.00
3924764151381NoneMan268Supplying, fabricating and fixing of Stainless steel cladding for walls using 304 grade Stainless steel 16 guage sheet wall cladding of thickness over the frame made out of 50x50mmx3mm thickness anodized aluminium frame work at an equal distance of 2 ft vertifically fixed to the wall using 100mm screws, guttas, anchor bolts and fastners with all necessary bending and cutting as per the desing and site condition. The frame work finally to be finished with 12mm BWP plywood to receive the SS sheet on it uniformly. Including cost of all materials, mortar, labour, curing etc., complete as per specification. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Fourth FLOOR:Sqm13486.213486.25.0FalseNoneNoneFalseNoneFalse67431.00
3924765151381NoneMan269Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineerin charge and finished smooth.: Ground Floor:Sqm2928.452928.455.0FalseNoneNoneFalseNoneFalse14642.250
3924766151381NoneMan270Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineerin charge and finished smooth.: First Floor:Sqm2957.732957.735.0FalseNoneNoneFalseNoneFalse14788.650
3924767151381NoneMan271Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineerin charge and finished smooth.: Second Floor:Sqm2987.312987.3110.0FalseNoneNoneFalseNoneFalse29873.10
3924768151381NoneMan272Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineerin charge and finished smooth.: Third Floor:Sqm3017.183017.1810.0FalseNoneNoneFalseNoneFalse30171.80
3924769151381NoneMan273Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineerin charge and finished smooth.: Fourth Floor:Sqm3047.353047.3510.0FalseNoneNoneFalseNoneFalse30473.50
3924770151381NoneMan274Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 including cost of all materials, mortar, labour, curing etc., complete as per specification. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Ground Floor:Sqm4133.854133.8515.0FalseNoneNoneFalseNoneFalse62007.750
3924771151381NoneMan275Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 including cost of all materials, mortar, labour, curing etc., complete as per specification. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : First Floor:Sqm4175.194175.1910.0FalseNoneNoneFalseNoneFalse41751.90
3924772151381NoneMan276Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 including cost of all materials, mortar, labour, curing etc., complete as per specification. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Second Floor:Sqm4216.944216.9415.0FalseNoneNoneFalseNoneFalse63254.10
3924773151381NoneMan277Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 including cost of all materials, mortar, labour, curing etc., complete as per specification. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Third Floor:Sqm4259.114259.1115.0FalseNoneNoneFalseNoneFalse63886.650
3924774151381NoneMan278Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2 including cost of all materials, mortar, labour, curing etc., complete as per specification. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Fourth Floor:Sqm4301.74301.715.0FalseNoneNoneFalseNoneFalse64525.50
3924775151381NoneMan279Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Ground Floor:Cum2117.852117.85110.0FalseNoneNoneFalseNoneFalse232963.50
3924776151381NoneMan280Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : First Floor:Cum2139.032139.03110.0FalseNoneNoneFalseNoneFalse235293.30
3924777151381NoneMan281Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Second Floor:Cum2160.422160.42125.0FalseNoneNoneFalseNoneFalse270052.50
3924778151381NoneMan282Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Third Floor:Cum2182.022182.02110.0FalseNoneNoneFalseNoneFalse240022.20
3924779151381NoneMan283Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Fourth Floor:Cum2203.842203.84190.0FalseNoneNoneFalseNoneFalse418729.60
3924780151381NoneMan284Providing and laying Cement concrete flooring 75 mm thick with 20mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete. 75mm Thick: Lower Basement 01:Sqm887.91887.9135.0FalseNoneNoneFalseNoneFalse31076.850
3924781151381NoneMan285Providing and laying Cement concrete flooring 75 mm thick with 20mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete. 75mm Thick: Ground Floor:Sqm887.91887.9195.0FalseNoneNoneFalseNoneFalse84351.450
3924782151381NoneMan286Providing and laying Cement concrete flooring 75 mm thick with 20mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete. 75mm Thick: First Floor:Sqm896.79896.7935.0FalseNoneNoneFalseNoneFalse31387.650
3924783151381NoneMan287Providing and laying Cement concrete flooring 75 mm thick with 20mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete. 75mm Thick: Second Floor:Sqm905.76905.7635.0FalseNoneNoneFalseNoneFalse31701.60
3924784151381NoneMan288Providing and laying Cement concrete flooring 75 mm thick with 20mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete. 75mm Thick: Third Floor:Sqm914.82914.8235.0FalseNoneNoneFalseNoneFalse32018.70
3924785151381NoneMan289Providing and laying Cement concrete flooring 75 mm thick with 20mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete. 75mm Thick: Fourth Floor:Sqm923.97923.971485.0FalseNoneNoneFalseNoneFalse1372095.450
3924786151381NoneMan290Providing and laying cement concrete using 20mm and down size granite coarse aggregates and fine aggregates of ready mixed concrete for RCC works laid in 15 cm thick layers and well compacted including vibrating curing etc., for all super structure works with all lead and lift etc., complete. (exculsive of cost of steel and fabrication charges) including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Ready mixed Cement concrete M20. [Screed for Rays ways]. [Screed for Rays ways, Above Cinder and Concrete Band for 100mm Wall] : (i). Ground Floor:Cum6961.56961.5148.0FalseNoneNoneFalseNoneFalse1030302.00
3924787151381NoneMan291Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates TERRACE FLOOR. Average 100mm Thick.Cum6961.56961.524.0FalseNoneNoneFalseNoneFalse167076.00
3924788151381NoneMan292Providing and laying cement concrete using 20mm and down size granite coarse aggregates and fine aggregates of ready mixed concrete for RCC works laid in 15 cm thick layers and well compacted including vibrating curing etc., for all super structure works with all lead and lift etc., complete. (exculsive of cost of steel and fabrication charges) including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Ready mixed Cement concrete M20. [Screed for Rays ways]. [Screed for Rays ways, Above Cinder and Concrete Band for 100mm Wall] : (ii). First Floor:Cum7031.127031.12140.0FalseNoneNoneFalseNoneFalse984356.80
3924789151381NoneMan293Providing and laying cement concrete using 20mm and down size granite coarse aggregates and fine aggregates of ready mixed concrete for RCC works laid in 15 cm thick layers and well compacted including vibrating curing etc., for all super structure works with all lead and lift etc., complete. (exculsive of cost of steel and fabrication charges) including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Ready mixed Cement concrete M20. [Screed for Rays ways]. [Screed for Rays ways, Above Cinder and Concrete Band for 100mm Wall] : (iii). Second Floor:Cum7101.437101.4315.0FalseNoneNoneFalseNoneFalse106521.450
3924790151381NoneMan294Providing and laying cement concrete using 20mm and down size granite coarse aggregates and fine aggregates of ready mixed concrete for RCC works laid in 15 cm thick layers and well compacted including vibrating curing etc., for all super structure works with all lead and lift etc., complete. (exculsive of cost of steel and fabrication charges) including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Ready mixed Cement concrete M20. [Screed for Rays ways]. [Screed for Rays ways, Above Cinder and Concrete Band for 100mm Wall] : (iii). Third Floor:Cum7172.447172.4415.0FalseNoneNoneFalseNoneFalse107586.60
3924791151381NoneMan295Providing and laying cement concrete using 20mm and down size granite coarse aggregates and fine aggregates of ready mixed concrete for RCC works laid in 15 cm thick layers and well compacted including vibrating curing etc., for all super structure works with all lead and lift etc., complete. (exculsive of cost of steel and fabrication charges) including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Ready mixed Cement concrete M20. [Screed for Rays ways]. [Screed for Rays ways, Above Cinder and Concrete Band for 100mm Wall] : (iii). Fourth Floor:Cum7244.167244.1625.0FalseNoneNoneFalseNoneFalse181104.00
3924792151381NoneMan296Providing and fixing corrugated G.S. sheet roofing including vertical curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. 0.63 mm thick with zinc coating not less than 275 g m²Sqm950.92950.922031.0FalseNoneNoneFalseNoneFalse1931318.520
3924793151381NoneMan297Providing and fixing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete as per design drawings. 0.63 mm thick with zinc coating not less than 275 g m²Rmtr691.28691.28750.0FalseNoneNoneFalseNoneFalse518460.00
3924794151381NoneMan298Providing and fixing 15 cm wide, 45 cm overall semicircular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. (0.63 mm thick with zinc coating not less than 275 g m²)Rmtr697.77697.77213.0FalseNoneNoneFalseNoneFalse148625.010
3924795151381NoneMan299DOORS, WINDOWS: and VENTILATORS: Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. red salCum105851.72105851.728.0FalseNoneNoneFalseNoneFalse846813.760
3924796151381NoneMan300Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Fixing of Door FrameNos1088.351088.35140.0FalseNoneNoneFalseNoneFalse152369.00
3924797151381NoneMan301Providing and fixing factory made single extruded Wood Polymer Composite (WPC) solid door window Ceosetory windows and Frames Chowkhat of Frame size 65 x 125 mm including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.Rmtr818.4818.4305.0FalseNoneNoneFalseNoneFalse249612.00
3924798151381NoneMan302Providing and fixing to existing door frames. Providing and fixing factory made 100percent Carpenter friendly ready to use Single Solid Plain Wood Polymer composite (WPC) flush shutter of 35mm thickness which is anti termite and having high water absorption property. The cost includes cost of materials, transportation, Labour and fixing charges. 35 mm thick including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.Sqm4328.764328.76145.0FalseNoneNoneFalseNoneFalse627670.20
3924799151381NoneMan303Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (partI) 1991. from manufacturer complete as per spcification. 40 mm thick both side Teak Single Double Leaf DoorSqm4331.984331.98190.0FalseNoneNoneFalseNoneFalse823076.20
3924800151381NoneMan304Providing and fixing Double Shutter Glass Door of 12mm Thick Plain Toughened Glass of approved makke. The door is fixed by using any approved make hardware fitting like patch fitting, pivot, floor machine, locking arrangements and suitable SS Door rails with floral Glass etching for 1 3 Portion of door area etc.,,, complete. The rate includes cost of all materials, labour, hire of tools and machineries, as per the specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.Sqm5058.265058.26125.0FalseNoneNoneFalseNoneFalse632282.50
3924801151381NoneMan305SPECIFICATION for UPVC VENTILATOR with FIXED LOUVERS: Providing and fixing of Louvered Ventilator made out of multi chambered UPVC (Matching to RAL9016) sections and with minimum TiO2 (Titanium Dioxide) at 6PHR with TPV (Thermo Plastic Vulcanized) and lead free with gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile thoroughout the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (Powder Coated in White) will be used on the frame along with plastic parts for fixing the 4mm pin head glass. Wall thickness of frame shall be 2mm. Maximum Possible size 1500mm x 1000mm. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.Sqm6126.266126.2632.0FalseNoneNoneFalseNoneFalse196040.320
3924802151381NoneMan306FIRE RATED DOOR: WOODEN FIRE RATED FLUSH DOOR:Providing , supply and fixing of Two Hours Fire rated timber door of specified size as per drawing with timber frame made out of Teak Wood Hard Wood (as per the Architect Suggestion and approval) with frame profile of 140 x 70mm with SINGLE REBATE FRAME with heat activated intumescent fire seal strip of 10mm x 4mm and two coat of anti termite with synthetic enamel paint of approved shade and shutters of 55mm thick asbestos freecomposite Fire Smoke check wooden shuttersof 120minutes fire resistance rating confirming to BS:476 Part 22 and IS: 2614 Part II. comprising of 12mm thick Calicium sillicate board sandwiching 25mm thickn proprietary fire resistane insulation material faced with 3mm commercial Ply on both side with heat activated inducement fire seal strip of size 10mm x 4mm mounted on grooves on three sides except bottom and two coats of anti termite fire retardant primer and anti termite primer, 1mm thick approved shade and pattern Laminate standard grade of approved colour (highland pine shade) and 4mm approved shade and pattern Veneer and Marquetry pattern. shall be faced with 1mm thick laminate standard grade of approved colour (highland pine shade) finish on both faces including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. The Hardware set for the Door are mentioned below: FD1 1500mm x 2400mm Wall openings size with VISION PANEL of Size 200 x 450mm as per Dwg. for Auditorium 1 Ball bearing butt hinge,SS304, of size 100 X 75 X 3mm with screws in SSS Homann 8 Nos 2. Mortice Sash Lock, H9GUBKS 2160, 65 BS 72 9mm, Rd.forend, strile, CE, CE, Silver finish,(LH) Hormann 1 No 3. Euro profile 5 pin cylinder 5702, 70mm key x key, NP finish Homann 1 No 4. Lever Handle LT 001, 19 Dia with roses and escutcheion, SS 304 , SSS finsih Homann 1 No 5. Surface door closer TS68, size EN2 3 4, with standard arm, Silver finish Dorma 2 Nos 6. Gravity door coordinator 390G , Dorma 1 No 7. Concealed flush bolt RB10 body Guardian 2 Nos 8. Rod for flush bolt 570mm Guardian 1 No 9. Surface auto door bottom 914mm, Aluminium finsih Hormann 2 No 10. Rod for flush bolt 265mm Guardian 1 No 11. Gasket, Fire rated 4mm Thick x 12mm, Black 7 Nos 12. Fire clear glass6mm 200x450mm 2 No 13. Fire and smoke seal C421 (Art. no. 315092), black Hormann sales 7 Nos 14. Installation Kit: Nylon Achor and other Misc items 1 NoSqm9660.09660.018.0FalseNoneNoneFalseNoneFalse173880.00
3924803151381NoneMan307120Mins with 30Mins. Insulated fire door as per IS 3614 Powder coated Providing and fixing of Heavy Duty hollow metal fire rated doors as per IS 3614, for stability,integrity and insulation. Pressed galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall be tested to IS 3614 part 2, IS ISO 8341, BS 476 Part 20 and 22, CBRI Cerifire, for maximum rating of 120mins with 30minutes of insulation. Labled fire doors shall be with fire rated hardware and vision panel all as a complete assembly. Manufacturer test certificate shall cover sizes of all doors supplied, deviation in sheet thickness other than what is mentioned in the BOQ are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Door frame must be single rebate grooved profile of size 125 x 55mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be mitered only. Frames shall be field assembled with self tabs. Bolted and butted joints are not acceptable. Frames to have inbuild grooved sealing system and shall be site fitted with fire rated EPDM C421 gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening.Once frame installed should be filled with PUF as recomended by the manufacturer or engineer incharge. Door leaf shall be minimum 46mm thick fully flush double skin door, Insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware of make Dorma Hormann Hafele. The infill material shall be high density insulation material. Intumescent seals 15x1.5mm to be provided all around the door in addition to the grooved smoke seal. The edges should be interlocked with a bending radius of 1.4mm, without any tak welding on edges. For pair of doors integral astragals has to be provided on the meeting stile for both active and inactive leaf. No surface mounted or weld joint astragals are acceptable. Vision lite wherever applicable should be 6mm clear borosilicate fire rated glass as per manufacturers recommendation with a clipon arrangement. Door and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of frame and shutter as a complete assembly including hardware. FD1 1500mm x 2400mm Wall openings size with VISION PANEL of Size 200 x 450mm as per Dwg. for Services Room The Hardware set for the Door are mentioned below: 1 Ball bearing butt hinge,SS304, of size 100 X 75 X 3mm with screws in SSS Homann 8 Nos 2. Mortice Sash Lock, H9GUBKS 2160, 65 BS 72 9mm, Rd.forend, strile, CE, CE, Silver finish,(LH) Hormann 1 No 3. Euro profile 5 pin cylinder 5702, 70mm key x key, NP finish Homann 1 No 4. Lever Handle LT 001, 19 Dia with roses and escutcheion, SS 304 , SSS finsih Homann 1 No 5. Surface door closer TS68, size EN2 3 4, with standard arm, Silver finish Dorma 2 Nos 6. Gravity door coordinator 390G , Dorma 1 No 7. Concealed flush bolt RB10 body Guardian 2 Nos 8. Rod for flush bolt 570mm Guardian 1 No 9. Surface auto door bottom 914mm, Aluminium finsih Hormann 2 No 10. Rod for flush bolt 265mm Guardian 1 No 11. Gasket, Fire rated 4mm Thick x 13mm, Black 7 Nos 12. Fire clear glass6mm 200x450mm 2 No 13. Fire and smoke seal C421 (Art. no. 315092), black Hormann sales 7 Nos 14. Installation Kit: Nylon Achor and other Misc items 1 NoSqm11839.011839.022.0FalseNoneNoneFalseNoneFalse260458.00
3924804151381NoneMan308120Mins with 30Mins. Insulated fire door as per IS 3614 Powder coated Providing and fixing of Heavy Duty hollow metal fire rated doors as per IS 3614, for stability,integrity and insulation. Pressed galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall be tested to IS 3614 part 2, IS ISO 8341, BS 476 Part 20 and 22, CBRI Cerifire, for maximum rating of 120mins with 30minutes of insulation. Labled fire doors shall be with fire rated hardware and vision panel all as a complete assembly. Manufacturer test certificate shall cover sizes of all doors supplied, deviation in sheet thickness other than what is mentioned in the BOQ are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Door frame must be single rebate grooved profile of size 125 x 55mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be mitered only. Frames shall be field assembled with self tabs. Bolted and butted joints are not acceptable. Frames to have inbuild grooved sealing system and shall be site fitted with fire rated EPDM C421 gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening.Once frame installed should be filled with PUF as recomended by the manufacturer or engineer incharge. Door leaf shall be minimum 46mm thick fully flush double skin door, Insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware of make Dorma Hormann Hafele. The infill material shall be high density insulation material. Intumescent seals 15x1.5mm to be provided all around the door in addition to the grooved smoke seal. The edges should be interlocked with a bending radius of 1.4mm, without any tak welding on edges. For pair of doors integral astragals has to be provided on the meeting stile for both active and inactive leaf. No surface mounted or weld joint astragals are acceptable. Vision lite wherever applicable should be 6mm clear borosilicate fire rated glass as per manufacturers recommendation with a clipon arrangement. Door and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of frame and shutter as a complete assembly including hardware. FD2 1800x2400mm Wall opening size with VISION PANEL of size 200 x 450mm as per Dwg. for Staircases. The Hardware set for the Door are mentioned below: 1 Ball bearing butt hinge,SS304, of size 100 X 75 X 3mm with screws in SSS Homann 8 Nos 2. Mortice Sash Lock, H9GUBKS 2160, 65 BS 72 9mm, Rd.forend, strile, CE, CE, Silver finish,(LH) Hormann 1 No 3. Euro profile 5 pin cylinder 5702, 70mm key x key, NP finish Homann 1 No 4. Lever Handle LT 001, 19 Dia with roses and escutcheion, SS 304 , SSS finsih Homann 1 No 5. Surface door closer TS68, size EN2 3 4, with standard arm, Silver finish Dorma 2 Nos 6. Gravity door coordinator 390G , Dorma 1 No 7. Concealed flush bolt RB10 body Guardian 2 Nos 8. Rod for flush bolt 570mm Guardian 1 No 9. Surface auto door bottom 914mm, Aluminium finsih Hormann 2 No 10. Rod for flush bolt 265mm Guardian 1 No 11. Gasket, Fire rated 4mm Thick x 13mm, Black 7 Nos 12. Fire clear glass6mm 200x450mm 2 No 13. Fire and smoke seal C421 (Art. no. 315092), black Hormann sales 7 Nos 14. Installation Kit: Nylon Achor and other Misc items 1 NoSqm10333.010333.052.0FalseNoneNoneFalseNoneFalse537316.00
3924805151381NoneMan309120Mins with 30Mins. Insulated fire door as per IS 3614 Powder coated Providing and fixing of Heavy Duty hollow metal fire rated doors as per IS 3614, for stability,integrity and insulation. Pressed galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall be tested to IS 3614 part 2, IS ISO 8341, BS 476 Part 20 and 22, CBRI Cerifire, for maximum rating of 120mins with 30minutes of insulation. Labled fire doors shall be with fire rated hardware and vision panel all as a complete assembly. Manufacturer test certificate shall cover sizes of all doors supplied, deviation in sheet thickness other than what is mentioned in the BOQ are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Door frame must be single rebate grooved profile of size 125 x 55mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be mitered only. Frames shall be field assembled with self tabs. Bolted and butted joints are not acceptable. Frames to have inbuild grooved sealing system and shall be site fitted with fire rated EPDM C421 gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening.Once frame installed should be filled with PUF as recomended by the manufacturer or engineer incharge. Door leaf shall be minimum 46mm thick fully flush double skin door, Insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware of make Dorma Hormann Hafele. The infill material shall be high density insulation material. Intumescent seals 15x1.5mm to be provided all around the door in addition to the grooved smoke seal. The edges should be interlocked with a bending radius of 1.4mm, without any tak welding on edges. For pair of doors integral astragals has to be provided on the meeting stile for both active and inactive leaf. No surface mounted or weld joint astragals are acceptable. Vision lite wherever applicable should be 6mm clear borosilicate fire rated glass as per manufacturers recommendation with a clipon arrangement. Door and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of frame and shutter as a complete assembly including hardware. FD2 1800x2400mm Wall opening size with VISION PANEL of size 200 x 450mm as per Dwg. for Staircases. The Hardware set for the Door are mentioned below: 1.Ball bearing butt hinge, SS304, of size 100 X 75 X 3mm with screws in SSS Homann 8Nos 2. Surface door closer TS68, size EN2 3 4, with standard arm, Silver finish Dorma 2 No 3. Surface auto door bottom 914 mm, Aluminium finish Hormann 2 No 4. Single point surface panic push bar 1211, Silver finish Hormann 4 No 5. External lever handle , 1185, with locking arrangement, Silver finish Hormann 2 No 6. Gasket, Fire rated 4mm Thick x 13mm , Black 4 Nos 7. Fire clear glass 6mm 200 X 450mm 2 No 8. Fire and Smoke seal C421 (Art. No. 315092), black Hormann Sales 8 Nos 9. Installation kit: Nylon Achor and other Misc items 1 noSqm11839.011839.052.0FalseNoneNoneFalseNoneFalse615628.00
3924806151381NoneMan310120Mins with 30Mins. Insulated fire door as per IS 3614 Powder coated Providing and fixing of Heavy Duty hollow metal fire rated doors as per IS 3614, for stability,integrity and insulation. Pressed galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall be tested to IS 3614 part 2, IS ISO 8341, BS 476 Part 20 and 22, CBRI Cerifire, for maximum rating of 120mins with 30minutes of insulation. Labled fire doors shall be with fire rated hardware and vision panel all as a complete assembly. Manufacturer test certificate shall cover sizes of all doors supplied, deviation in sheet thickness other than what is mentioned in the BOQ are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Door frame must be single rebate grooved profile of size 125 x 55mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be mitered only. Frames shall be field assembled with self tabs. Bolted and butted joints are not acceptable. Frames to have inbuild grooved sealing system and shall be site fitted with fire rated EPDM C421 gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening.Once frame installed should be filled with PUF as recomended by the manufacturer or engineer incharge. Door leaf shall be minimum 46mm thick fully flush double skin door, Insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware of make Dorma Hormann Hafele. The infill material shall be high density insulation material. Intumescent seals 15x1.5mm to be provided all around the door in addition to the grooved smoke seal. The edges should be interlocked with a bending radius of 1.4mm, without any tak welding on edges. For pair of doors integral astragals has to be provided on the meeting stile for both active and inactive leaf. No surface mounted or weld joint astragals are acceptable. Vision lite wherever applicable should be 6mm clear borosilicate fire rated glass as per manufacturers recommendation with a clipon arrangement. Door and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of frame and shutter as a complete assembly including hardware. FD2 1200x2400mm Wall opening size with VISION PANEL of 200mm x 450mm as per dwg. for ELECTRICAL Room The Hardware set for the Door are mentioned below: 1. Ball bearing Butt Hinges, SS304, 100 x 75 x 3mm with Screws in SSS: Hormann 4 Nos. 2. Single Point Surface Panic Push bar 1211, Silver finish Hormann 1 Nos. 3.External Lever Handle, 1185, wtih locking arrangement, Silver finish Hormann 1 Nos.. 4. Surface Door Closure TS68, Size EN2 3 4, with Standard arm, Silver finish: Dorma 1 Nos. 5. Fire Clear Glass 6mm: 120 min. of size 200 x 450mm 1 Nos. 6. Fire and smoke seal C421 (Art No. 315092), Black Hormann Sales 6 Nos. 7. Surface Auto Door Bottom 914mm, Aluminium Finish Hormann 1 Nos. 8. Gasket, Fire rated 4mm Thick X 13mm, Black 4 Nos. 9. Installation Kit: Nylon Achor and other Miscellaneous Items 1 Nos.Sqm9550.09550.070.0FalseNoneNoneFalseNoneFalse668500.00
3924807151381NoneMan311120Mins with 30Mins. Insulated fire door as per IS 3614 Powder coated Providing and fixing of Heavy Duty hollow metal fire rated doors as per IS 3614, for stability,integrity and insulation. Pressed galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall be tested to IS 3614 part 2, IS ISO 8341, BS 476 Part 20 and 22, CBRI Cerifire, for maximum rating of 120mins with 30minutes of insulation. Labled fire doors shall be with fire rated hardware and vision panel all as a complete assembly. Manufacturer test certificate shall cover sizes of all doors supplied, deviation in sheet thickness other than what is mentioned in the BOQ are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Door frame must be single rebate grooved profile of size 125 x 55mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be mitered only. Frames shall be field assembled with self tabs. Bolted and butted joints are not acceptable. Frames to have inbuild grooved sealing system and shall be site fitted with fire rated EPDM C421 gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening.Once frame installed should be filled with PUF as recomended by the manufacturer or engineer incharge. Door leaf shall be minimum 46mm thick fully flush double skin door, Insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware of make Dorma Hormann Hafele. The infill material shall be high density insulation material. Intumescent seals 15x1.5mm to be provided all around the door in addition to the grooved smoke seal. The edges should be interlocked with a bending radius of 1.4mm, without any tak welding on edges. For pair of doors integral astragals has to be provided on the meeting stile for both active and inactive leaf. No surface mounted or weld joint astragals are acceptable. Vision lite wherever applicable should be 6mm clear borosilicate fire rated glass as per manufacturers recommendation with a clipon arrangement. Door and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of frame and shutter as a complete assembly including hardware. SD 01: 900x1800mm Wall opening size with VISION PANEL of Size 200 x 450mm as per Dwg. for FHC. The Hardware set for the Door are mentioned below: 1. Ball bearing butt hinge, SS304, of size 100 X 75 X 3mm with screws in SSS Homann 3 Nos 2. Mortise shaft lolck H7, 57mm BS, with Allen Key and escutcheons, sss Hormann 1 No 3. Flush handle, CH 120S, 120X40mm, SSS finish Hormann 4. Fire and Smoke seal C421 (Art. No. 315092), black Hormann Sales 5 Nos 5. Gasket, Fire rated 4mm Thick x 13mm , Black 4 Nos 6. Fire clear glass 6mm 200 X 300mm 1 No 7. Installation kit: Nylon Achor and other Misc items 1 noSqm9850.09850.034.0FalseNoneNoneFalseNoneFalse334900.00
3924808151381NoneMan312120Mins with 30Mins. Insulated fire door as per IS 3614 Powder coated Providing and fixing of Heavy Duty hollow metal fire rated doors as per IS 3614, for stability,integrity and insulation. Pressed galvanized steel confirming to IS 277 with the following specification. Recommended fire door shall be tested to IS 3614 part 2, IS ISO 8341, BS 476 Part 20 and 22, CBRI Cerifire, for maximum rating of 120mins with 30minutes of insulation. Labled fire doors shall be with fire rated hardware and vision panel all as a complete assembly. Manufacturer test certificate shall cover sizes of all doors supplied, deviation in sheet thickness other than what is mentioned in the BOQ are not allowed. Proper label confirming the type of door and the hourly rating is mandatory. Door frame must be single rebate grooved profile of size 125 x 55mm made out of 1.60mm (16gauge) minimum thick galvanized steel sheet. Frames shall be mitered only. Frames shall be field assembled with self tabs. Bolted and butted joints are not acceptable. Frames to have inbuild grooved sealing system and shall be site fitted with fire rated EPDM C421 gasket as standard. All provision should be mortised, drilled and tapped for receiving appropriate hardware. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening.Once frame installed should be filled with PUF as recomended by the manufacturer or engineer incharge. Door leaf shall be minimum 46mm thick fully flush double skin door, Insulated with or without vision lite. Door leaf shall be manufactured from 1.2mm (18guage) minimum thick galvanised steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware of make Dorma Hormann Hafele. The infill material shall be high density insulation material. Intumescent seals 15x1.5mm to be provided all around the door in addition to the grooved smoke seal. The edges should be interlocked with a bending radius of 1.4mm, without any tak welding on edges. For pair of doors integral astragals has to be provided on the meeting stile for both active and inactive leaf. No surface mounted or weld joint astragals are acceptable. Vision lite wherever applicable should be 6mm clear borosilicate fire rated glass as per manufacturers recommendation with a clipon arrangement. Door and frames shall be finished Pure Polyster Powder coated and shall have passed minimum 500 hours of salt sprey test. Rate shall include supply and installation of frame and shutter as a complete assembly including hardware. SD 02: 900x2100mm Wall opening size with VISION PANEL of Size 200 x 450mm as per Dwg. for SHAFT. The Hardware set for the Door are mentioned below: 1. Ball bearing butt hinge, SS304, of size 100 X 75 X 3mm with screws in SSS Homann 3 Nos 2. Mortise shaft lolck H7, 57mm BS, with Allen Key and escutcheons, sss Hormann 1 No 3. Flush handle, CH 120S, 120X40mm, SSS finish Hormann 4. Fire and Smoke seal C421 (Art. No. 315092), black Hormann Sales 5 Nos 5. Gasket, Fire rated 4mm Thick x 13mm , Black 4 Nos 6. Fire clear glass 6mm 200 X 300mm 1 No 7. Installation kit: Nylon Achor and other Misc items 1 noSqm9850.09850.058.0FalseNoneNoneFalseNoneFalse571300.00
3924809151381NoneMan313RAILING WORK: Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineerin charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Lower Basement 01:Kgs593.25593.25204.0FalseNoneNoneFalseNoneFalse121023.00
3924810151381NoneMan314RAILING WORK: Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineerin charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Ground Floor:Kgs593.25593.25444.0FalseNoneNoneFalseNoneFalse263403.00
3924811151381NoneMan315RAILING WORK: Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineerin charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : First Floor:Kgs599.18599.18204.0FalseNoneNoneFalseNoneFalse122232.720
3924812151381NoneMan316RAILING WORK: Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineerin charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Second Floor:Kgs605.17605.17204.0FalseNoneNoneFalseNoneFalse123454.680
3924813151381NoneMan317RAILING WORK: Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineerin charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Third Floor:Kgs611.22611.22204.0FalseNoneNoneFalseNoneFalse124688.880
3924814151381NoneMan318RAILING WORK: Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i c fixing the railing with necessary accessories and stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineerin charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Fourth Floor:Kgs617.33617.33204.0FalseNoneNoneFalseNoneFalse125935.320
3924815151381NoneMan319Providing and fixing STAINLESS STEEL MATT FINISHED 304 GRADE for Staircase GRIP RAILINGS, balconies, ramps, with hand rail, 50mm dia 16 guage hollow pipe fixed to hollow 25mm dia pipe of 16 guage and welded to 100mm x 100mm x 6mm Thick S.S. plate as per drawing, stainless steel supporting pipe and Plates spaced at 1.20m regular intervals. The entire assembly is fixed to Wall or concrete by using expansion bolts of 8mm Dia by drilling etc., complete including cost of materials, labour, HOM of machineries and electrical charges, etc., complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: Lower Basement 01:Rmtr1750.01750.046.0FalseNoneNoneFalseNoneFalse80500.00
3924816151381NoneMan320Providing and fixing STAINLESS STEEL MATT FINISHED 304 GRADE for Staircase GRIP RAILINGS, balconies, ramps, with hand rail, 50mm dia 16 guage hollow pipe fixed to hollow 25mm dia pipe of 16 guage and welded to 100mm x 100mm x 6mm Thick S.S. plate as per drawing, stainless steel supporting pipe and Plates spaced at 1.20m regular intervals. The entire assembly is fixed to Wall or concrete by using expansion bolts of 8mm Dia by drilling etc., complete including cost of materials, labour, HOM of machineries and electrical charges, etc., complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: Ground Floor:Rmtr1750.01750.044.0FalseNoneNoneFalseNoneFalse77000.00
3924817151381NoneMan321Providing and fixing STAINLESS STEEL MATT FINISHED 304 GRADE for Staircase GRIP RAILINGS, balconies, ramps, with hand rail, 50mm dia 16 guage hollow pipe fixed to hollow 25mm dia pipe of 16 guage and welded to 100mm x 100mm x 6mm Thick S.S. plate as per drawing, stainless steel supporting pipe and Plates spaced at 1.20m regular intervals. The entire assembly is fixed to Wall or concrete by using expansion bolts of 8mm Dia by drilling etc., complete including cost of materials, labour, HOM of machineries and electrical charges, etc., complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: First Floor:Rmtr1750.01750.046.0FalseNoneNoneFalseNoneFalse80500.00
3924818151381NoneMan322Providing and fixing STAINLESS STEEL MATT FINISHED 304 GRADE for Staircase GRIP RAILINGS, balconies, ramps, with hand rail, 50mm dia 16 guage hollow pipe fixed to hollow 25mm dia pipe of 16 guage and welded to 100mm x 100mm x 6mm Thick S.S. plate as per drawing, stainless steel supporting pipe and Plates spaced at 1.20m regular intervals. The entire assembly is fixed to Wall or concrete by using expansion bolts of 8mm Dia by drilling etc., complete including cost of materials, labour, HOM of machineries and electrical charges, etc., complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: Second Floor:Rmtr1750.01750.052.0FalseNoneNoneFalseNoneFalse91000.00
3924819151381NoneMan323Providing and fixing STAINLESS STEEL MATT FINISHED 304 GRADE for Staircase GRIP RAILINGS, balconies, ramps, with hand rail, 50mm dia 16 guage hollow pipe fixed to hollow 25mm dia pipe of 16 guage and welded to 100mm x 100mm x 6mm Thick S.S. plate as per drawing, stainless steel supporting pipe and Plates spaced at 1.20m regular intervals. The entire assembly is fixed to Wall or concrete by using expansion bolts of 8mm Dia by drilling etc., complete including cost of materials, labour, HOM of machineries and electrical charges, etc., complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: Third Floor:Rmtr1750.01750.052.0FalseNoneNoneFalseNoneFalse91000.00
3924820151381NoneMan324Providing and fixing STAINLESS STEEL MATT FINISHED 304 GRADE for Staircase GRIP RAILINGS, balconies, ramps, with hand rail, 50mm dia 16 guage hollow pipe fixed to hollow 25mm dia pipe of 16 guage and welded to 100mm x 100mm x 6mm Thick S.S. plate as per drawing, stainless steel supporting pipe and Plates spaced at 1.20m regular intervals. The entire assembly is fixed to Wall or concrete by using expansion bolts of 8mm Dia by drilling etc., complete including cost of materials, labour, HOM of machineries and electrical charges, etc., complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: Fourth Floor:Rmtr1750.01750.052.0FalseNoneNoneFalseNoneFalse91000.00
3924821151381NoneMan325Providing and fixing STAINLESS STEEL MATT FINISHED 304 GRADE for Staircase GRIP RAILINGS, balconies, ramps, with hand rail, 50mm dia 16 guage hollow pipe fixed to hollow 25mm dia pipe of 16 guage and welded to 100mm x 100mm x 6mm Thick S.S. plate as per drawing, stainless steel supporting pipe and Plates spaced at 1.20m regular intervals. The entire assembly is fixed to Wall or concrete by using expansion bolts of 8mm Dia by drilling etc., complete including cost of materials, labour, HOM of machineries and electrical charges, etc., complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: Fifth Floor:Rmtr1750.01750.052.0FalseNoneNoneFalseNoneFalse91000.00
3924822151381NoneMan326MISCELLANEOUS ITEMS: Toilet cubicles with door Providing and installing Cubicles as per the sizes mentioned in drawings of approved colour and pattern having cubicle height of 2000mm, cubicles made using solid grade high pressure laminate as per IS:2046 and EN 138, having scratch, abrasion, water resistance, heat, chemical, impact and moisture resistance with anti bacterial properties. All doors are single colour of 12mm thick compact HPL, each door supported by 3 SS hinges affixed to pilasters, SS Coat hook, SS door knob, all door will routed at the vertical ends and rubber sponge lining will be incorporated at the routed ends, Pilaster will be made of 12mm thick HPL with SS lock set ( comprised of thumb turn and occupancy indicator), pilaster will be anchored to floor with SS adjustable legs. all intermediate dividers partitions made of 12mm thick HPL affixed to SS U channel at their ends for stability, cubicle having accessories SS 304 grade top rail of size 55x42x1.6mm, SS Corner joinery section, Adjustable pedestal footing of 60mm dia SS 316 grade adjustable to 100150mm height, SS spring loaded butt hinges, SS coat hook with rubber stopper, SS round knob 30mm dia, SS rotating thumb knob locking system, anti noise rubber padding 2mm thk and 10mm wide, complete work at all levels and heights, lead, lift, scaffolding, clearing the debris, as directed by the Architects. ( MERINO TITAN STANDRAD Series or equivalent) : FOURTH FLOOR.Nos34500.034500.020.0FalseNoneNoneFalseNoneFalse690000.00
3924823151381NoneMan327Providing and laying heavy duty cobble stones 75mm thick interlock pavers, using cement and course sand for manufacture of blocks of approved size, shape and colour with a minimum compressive strength of 30MPa as per IRC SP 63:2018 and IS 1565B over 50mm thick sand bed ( average thickness ) and compacting with plate vibrator having 3 tons compaction force thereby forcing part of sand underneath to come up in between joints, final compaction of paver surface joints into its final level, including cost of materials, labour and Usage charges of machinery complete as per specifications including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Specification No. KBS heavy duty cobble stones 75mm thick: (i). Ground Floor: (Level 02):Sqm1219.051219.05385.0FalseNoneNoneFalseNoneFalse469334.250
3924824151381NoneMan328Providing and fixing M.S. Grill over existing compound wall as per using 16mm x 16mm M.S. Square rod at 150mm c c spacing and 6mm x 40mm M.S. flats at horizontal and 6mm x12mm M.S. flat for ornamental design and providing shop edge design at the vertex of every vertical rods, including welding, grinding wherever necessary. All the steel surface should be thoroughly cleaned free of rust and painted with anti corrosive paint (shop paint) etc., complete. The work includes cost of all materials, labour charges for all items of work, hire charges for welding, cutting and grinding equipment, and electricity charges, etc., complete as per specification. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.Sqm5637.455637.45206.0FalseNoneNoneFalseNoneFalse1161314.70
3924825151381NoneMan329Providing and fixing M.S. Gate as per Chief Architect Drawing, using 50mm x 50mm 14 guage M.S. hollow pipe frame work bent to ornamental shape as shown in the drawing and 35mm x 6mm and 16 x 16mm Square rods for verticals alternatively spaced at 4cms c c in two halves and 40mmx6mm M.S. flats for horizontal member and at the top cast iron spikes are provided at alternate vertical members as shown in the drawing etc., complete. All the steel surface should be thoroughly cleaned free of rust and painted with anti corrosive paint (shop paint) etc., complete. The work includes cost of all materials, labour charges for all items of work, hire charges for welding, cutting and grinding equipment, and electricity charges, with lead and lift, loading and unloading charges, etc., complete as per specification. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.Sqm3162.63162.636.0FalseNoneNoneFalseNoneFalse113853.60
3924826151381NoneMan330Cast in Situ Cement Concrete M 20 Kerb with Channel: Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 15 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409: PCC M15 grade for kerb baseRmtr389.55389.55484.0FalseNoneNoneFalseNoneFalse188542.20
3924827151381NoneMan331Cast in Situ Cement Concrete M 20 Kerb with Channel: Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 15 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 409: PCC M20 grade for kerb Cast in SituRmtr389.55389.55484.0FalseNoneNoneFalseNoneFalse188542.20
3924828151381NoneMan332Supplying and fixing M.S. Rectangular poles made out of 2 equal angles of 65x65x6 mm welded together and fixed in CC (1:2:4) WITH 2 NOS 16mm dia M.S. hold fast rods each of length 25 cms. Including cost of all materials cutting, bending scaffolding wherever necessary, nicely finishing the welded joints with all lead lifts and as per the directions of the Engineerin charge of the work and including providing 2 coats of approved quality paint over one coat of shop painting ( excluding cost of earthwork and concrete) including cost of materials, labour, HOM complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. including cost of materials, labour, HOM complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.Rmtr880.95880.95410.0FalseNoneNoneFalseNoneFalse361189.50
3924829151381NoneMan333Providing and fixing M.S. Block pipe of 38mm dia, of heavy guage of 14 including removing the bends, cutting the pipe, and fixing pipe in between the existing two verticle poles (M.S. rectangular poles) and spot welding the chain link with M.S. block pipe including cost of all materials wastage in cutting, and scaffolding wherever necessary with all lead and lift as directed by the Engineerincharge of work etc., complete including two coats of approved quality paint over one coat of shop paint, including cost of materials, labour, HOM complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. M.S. Block pipe of 38mm dia, of heavy guage of 14Rmtr428.4428.460.0FalseNoneNoneFalseNoneFalse25704.00
3924830151381NoneMan334Chain Link Fencing: Providing and fixing G.I. chain link fabric fencing of required width in mesh size 50x50 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineerincharge. (Made of G.I. wire of dia. 4 mm, PVC coated to achieve outer dia not less than 5 mm in required colour and shade)including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.Sqm883.05883.0525.0FalseNoneNoneFalseNoneFalse22076.250
3924831151381NoneMan335Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge.Kgs142.8142.8375.0FalseNoneNoneFalseNoneFalse53550.00
3924832151381NoneMan336Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Single leaf door ofsize 3.00 m x2.40 mSqm4701.94701.914.0FalseNoneNoneFalseNoneFalse65826.60
3924833151381NoneMan337PAINTING WORKS: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge including cost of all materials, cost of labour and scaffolding, etc., complete as per specifictions. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Area to be considered 100percent for fresh Surface. CEILING : Lower Basement 01Sqm105.0105.04205.0FalseNoneNoneFalseNoneFalse441525.00
3924834151381NoneMan338PAINTING WORKS: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge including cost of all materials, cost of labour and scaffolding, etc., complete as per specifictions. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Area to be considered 100percent for fresh Surface. CEILING : Ground FloorSqm105.0105.03295.0FalseNoneNoneFalseNoneFalse345975.00
3924835151381NoneMan339PAINTING WORKS: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge including cost of all materials, cost of labour and scaffolding, etc., complete as per specifictions. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Area to be considered 100percent for fresh Surface. CEILING : First FloorSqm106.05106.054090.0FalseNoneNoneFalseNoneFalse433744.50
3924836151381NoneMan340PAINTING WORKS: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge including cost of all materials, cost of labour and scaffolding, etc., complete as per specifictions. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Area to be considered 100percent for fresh Surface. CEILING : Second FloorSqm107.11107.113395.0FalseNoneNoneFalseNoneFalse363638.450
3924837151381NoneMan341PAINTING WORKS: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge including cost of all materials, cost of labour and scaffolding, etc., complete as per specifictions. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Area to be considered 100percent for fresh Surface. CEILING : Third FloorSqm108.18108.184080.0FalseNoneNoneFalseNoneFalse441374.40
3924838151381NoneMan342PAINTING WORKS: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge including cost of all materials, cost of labour and scaffolding, etc., complete as per specifictions. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Area to be considered 100percent for fresh Surface. CEILING : Fourth FloorSqm109.26109.261970.0FalseNoneNoneFalseNoneFalse215242.20
3924839151381NoneMan343PAINTING WORKS: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge including cost of all materials, cost of labour and scaffolding, etc., complete as per specifictions. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Area to be considered 100percent for fresh Surface. CEILING : Fifth FloorSqm110.35110.35780.0FalseNoneNoneFalseNoneFalse86073.00
3924840151381NoneMan344PAINTING WORKS: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge including cost of all materials, cost of labour and scaffolding, etc., complete as per specifictions. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Area to be considered 100percent for fresh Surface. WALL:Lower Basement 01Sqm105.0105.01475.0FalseNoneNoneFalseNoneFalse154875.00
3924841151381NoneMan345PAINTING WORKS: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge including cost of all materials, cost of labour and scaffolding, etc., complete as per specifictions. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Area to be considered 100percent for fresh Surface. WALL: Ground FloorSqm105.0105.03420.0FalseNoneNoneFalseNoneFalse359100.00
3924842151381NoneMan346PAINTING WORKS: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge including cost of all materials, cost of labour and scaffolding, etc., complete as per specifictions. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Area to be considered 100percent for fresh Surface. WALL: First FloorSqm106.05106.053075.0FalseNoneNoneFalseNoneFalse326103.750
3924843151381NoneMan347PAINTING WORKS: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge including cost of all materials, cost of labour and scaffolding, etc., complete as per specifictions. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Area to be considered 100percent for fresh Surface. WALL: Second FloorSqm107.11107.112815.0FalseNoneNoneFalseNoneFalse301514.650
3924844151381NoneMan348PAINTING WORKS: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge including cost of all materials, cost of labour and scaffolding, etc., complete as per specifictions. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Area to be considered 100percent for fresh Surface. WALL: Third FloorSqm108.18108.182740.0FalseNoneNoneFalseNoneFalse296413.20
3924845151381NoneMan349PAINTING WORKS: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge including cost of all materials, cost of labour and scaffolding, etc., complete as per specifictions. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Area to be considered 100percent for fresh Surface. WALL: Fourth FloorSqm109.26109.262000.0FalseNoneNoneFalseNoneFalse218520.00
3924846151381NoneMan350PAINTING WORKS: Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge including cost of all materials, cost of labour and scaffolding, etc., complete as per specifictions. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Area to be considered 100percent for fresh Surface. WALL: Fifth FloorSqm110.35110.351510.0FalseNoneNoneFalseNoneFalse166628.50
3924847151381NoneMan3511. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams litre as per specifications and as per directions of Engineer in charge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargeincluding with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Wall : Lower Basement 01Sqm171.15171.152005.0FalseNoneNoneFalseNoneFalse343155.750
3924848151381NoneMan3521. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams litre as per specifications and as per directions of Engineer in charge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargeincluding with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Wall : Ground FloorSqm171.15171.153465.0FalseNoneNoneFalseNoneFalse593034.750
3924849151381NoneMan3531. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams litre as per specifications and as per directions of Engineer in charge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargeincluding with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Wall : First FloorSqm172.86172.863075.0FalseNoneNoneFalseNoneFalse531544.50
3924850151381NoneMan3541. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams litre as per specifications and as per directions of Engineer in charge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargeincluding with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Wall : Second FloorSqm174.59174.592815.0FalseNoneNoneFalseNoneFalse491470.850
3924851151381NoneMan3551. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams litre as per specifications and as per directions of Engineer in charge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargeincluding with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Wall : Third FloorSqm176.34176.342740.0FalseNoneNoneFalseNoneFalse483171.60
3924852151381NoneMan3561. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams litre as per specifications and as per directions of Engineer in charge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargeincluding with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Wall : Fourth FloorSqm178.1178.12000.0FalseNoneNoneFalseNoneFalse356200.00
3924853151381NoneMan3571. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams litre as per specifications and as per directions of Engineer in charge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargeincluding with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. Wall : Fifth FloorSqm179.88179.881510.0FalseNoneNoneFalseNoneFalse271618.80
3924854151381NoneMan3581. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams litre as per specifications and as per directions of Engineer in charge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. CEILING painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargeincluding with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. CEILING: Lower Basement 01Sqm171.15171.153675.0FalseNoneNoneFalseNoneFalse628976.250
3924855151381NoneMan3591. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams litre as per specifications and as per directions of Engineer in charge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. CEILING painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargeincluding with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. CEILING: Ground FloorSqm171.15171.153250.0FalseNoneNoneFalseNoneFalse556237.50
3924856151381NoneMan3601. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams litre as per specifications and as per directions of Engineer in charge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. CEILING painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargeincluding with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. CEILING: First FloorSqm172.86172.864090.0FalseNoneNoneFalseNoneFalse706997.40
3924857151381NoneMan3611. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams litre as per specifications and as per directions of Engineer in charge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. CEILING painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargeincluding with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. CEILING: Second FloorSqm174.59174.593395.0FalseNoneNoneFalseNoneFalse592733.050
3924858151381NoneMan3621. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams litre as per specifications and as per directions of Engineer in charge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. CEILING painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargeincluding with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. CEILING: Third FloorSqm176.34176.344080.0FalseNoneNoneFalseNoneFalse719467.20
3924859151381NoneMan3631. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams litre as per specifications and as per directions of Engineer in charge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. CEILING painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargeincluding with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. CEILING: Fourth FloorSqm178.1178.11970.0FalseNoneNoneFalseNoneFalse350857.00
3924860151381NoneMan3641. Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 grams litre as per specifications and as per directions of Engineer in charge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. CEILING painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in chargeincluding with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. CEILING: Fifth FloorSqm179.88179.88780.0FalseNoneNoneFalseNoneFalse140306.40
3924861151381NoneMan365Finishing walls with textured exterior paint of required shade :New work (Two coats applied at 3.28 ltr 10 m²) over and including priming coat of exterior primer applied at 2.20kg 10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Lower Basement 01Sqm297.15297.15210.0FalseNoneNoneFalseNoneFalse62401.50
3924862151381NoneMan366Finishing walls with textured exterior paint of required shade :New work (Two coats applied at 3.28 ltr 10 m²) over and including priming coat of exterior primer applied at 2.20kg 10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Ground FloorSqm297.15297.151257.0FalseNoneNoneFalseNoneFalse373517.550
3924863151381NoneMan367Finishing walls with textured exterior paint of required shade :New work (Two coats applied at 3.28 ltr 10 m²) over and including priming coat of exterior primer applied at 2.20kg 10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : First FloorSqm300.12300.121205.0FalseNoneNoneFalseNoneFalse361644.60
3924864151381NoneMan368Finishing walls with textured exterior paint of required shade :New work (Two coats applied at 3.28 ltr 10 m²) over and including priming coat of exterior primer applied at 2.20kg 10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Second FloorSqm303.12303.12975.0FalseNoneNoneFalseNoneFalse295542.00
3924865151381NoneMan369Finishing walls with textured exterior paint of required shade :New work (Two coats applied at 3.28 ltr 10 m²) over and including priming coat of exterior primer applied at 2.20kg 10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Third FloorSqm306.15306.15915.0FalseNoneNoneFalseNoneFalse280127.250
3924866151381NoneMan370Finishing walls with textured exterior paint of required shade :New work (Two coats applied at 3.28 ltr 10 m²) over and including priming coat of exterior primer applied at 2.20kg 10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Fourth FloorSqm309.21309.21915.0FalseNoneNoneFalseNoneFalse282927.150
3924867151381NoneMan371Finishing walls with textured exterior paint of required shade :New work (Two coats applied at 3.28 ltr 10 m²) over and including priming coat of exterior primer applied at 2.20kg 10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Fifth FloorSqm312.3312.3915.0FalseNoneNoneFalseNoneFalse285754.50
3924868151381NoneMan372Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer incharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. (Shaft Internal): Lower Basement 01:Sqm27.327.3295.0FalseNoneNoneFalseNoneFalse8053.50
3924869151381NoneMan373Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer incharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. (Shaft Internal): Ground Floor:Sqm27.327.3580.0FalseNoneNoneFalseNoneFalse15834.00
3924870151381NoneMan374Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer incharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. (Shaft Internal): First Floor:Sqm27.5727.57565.0FalseNoneNoneFalseNoneFalse15577.050
3924871151381NoneMan375Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer incharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. (Shaft Internal): SECOND FLOOR:Sqm27.8527.85545.0FalseNoneNoneFalseNoneFalse15178.250
3924872151381NoneMan376Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer incharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. (Shaft Internal): THIRD FLOOR:Sqm28.1328.13545.0FalseNoneNoneFalseNoneFalse15330.850
3924873151381NoneMan377Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer incharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. (Shaft Internal): FOURTH FLOOR:Sqm28.4128.41545.0FalseNoneNoneFalseNoneFalse15483.450
3924874151381NoneMan378Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer incharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. (Shaft Internal): FIFTH FLOOR:Sqm28.6928.69545.0FalseNoneNoneFalseNoneFalse15636.050
3924875151381NoneMan379Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerinchargeincluding cost of materials, labour, complete as per specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works at all Levels.Sqm175.35175.35386.0FalseNoneNoneFalseNoneFalse67685.10
3924876151381NoneMan380Door Fixtures: Providing and fixing chromium plated brass butt hinges with necessary chromium plated brass screws etc. complete. 125x70x4 mm (ordinary type)Each178.5178.5456.0FalseNoneNoneFalseNoneFalse81396.00
3924877151381NoneMan381Providing and fixing bright finished brass flush bolts with necessary brass screws etc. complete : (a). 250 mmEach257.25257.2520.0FalseNoneNoneFalseNoneFalse5145.00
3924878151381NoneMan382Providing and fixing bright finished brass flush bolts with necessary brass screws etc. complete : (b). 150 mmEach222.6222.620.0FalseNoneNoneFalseNoneFalse4452.00
3924879151381NoneMan383Providing and fixing bright finished brass flush bolts with necessary brass screws etc. complete : ( c). 100 mmEach172.2172.25.0FalseNoneNoneFalseNoneFalse861.00
3924880151381NoneMan384Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.Nos126.0126.048.0FalseNoneNoneFalseNoneFalse6048.00
3924881151381NoneMan385Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.Nos1039.51039.577.0FalseNoneNoneFalseNoneFalse80041.50
3924882151381NoneMan386Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.Nos1104.61104.667.0FalseNoneNoneFalseNoneFalse74008.20
3924883151381NoneMan387Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.Nos1169.71169.7114.0FalseNoneNoneFalseNoneFalse133345.80
3924884151381NoneMan388Providing and fixing chromium plated brass handles of 100 125 mm with necessary screws etc. completeNos248.85248.85114.0FalseNoneNoneFalseNoneFalse28368.90
3924885151381NoneMan389Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : (a). 200x10mmNos367.5367.570.0FalseNoneNoneFalseNoneFalse25725.00
3924886151381NoneMan390Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : (b). 150x10mmNos303.45303.45118.0FalseNoneNoneFalseNoneFalse35807.10
3924887151381NoneMan391Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125 mm with plate 175x32 mmEach261.45261.45134.0FalseNoneNoneFalseNoneFalse35034.30
3924888151381NoneMan392Providing and fixing Rectangular High Desnity Polyethylene water Storage Loft Tank with Cover, conforming to IS:12701, Colour of Opeque White or as approved by Engineerincharge. The rate includes making necessary holes for inlet, outlet and Over flow pipes. The base i c fittings and fixures for tank shall be paid seperately.Ltr9.459.4530000.0FalseNoneNoneFalseNoneFalse283500.00
3924889151381NoneMan393Providing and Fixing 2.5 Tonne Capacity Fiber Reinforced Polymer manhole cover (Recessed Type) of Size 600mm X 600mm X 33mm with locking arrangements including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.Nos6650.06650.015.0FalseNoneNoneFalseNoneFalse99750.00
3924890151381NoneMan394Supply and Fixing of PVC Rungs OF 300mm wide for Foot Rest in Water Tank at 400 mm c c. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.Nos450.0450.0225.0FalseNoneNoneFalseNoneFalse101250.00
3924891151381NoneMan395Providing and fixing 450mm puddle flanges inside walls of water tank including making opening water tight complete. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : 150mmNos3000.03000.06.0FalseNoneNoneFalseNoneFalse18000.00
3924892151381NoneMan396Providing and fixing 450mm puddle flanges inside walls of water tank including making opening water tight complete. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : 100mmNos2050.02050.06.0FalseNoneNoneFalseNoneFalse12300.00
3924893151381NoneMan397Providing and fixing 450mm puddle flanges inside walls of water tank including making opening water tight complete. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : 80mmNos1675.01675.06.0FalseNoneNoneFalseNoneFalse10050.00
3924894151381NoneMan398Providing and fixing 450mm puddle flanges inside walls of water tank including making opening water tight complete. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : 63mmNos1350.01350.06.0FalseNoneNoneFalseNoneFalse8100.00
3924895151381NoneMan399Providing and fixing 450mm puddle flanges inside walls of water tank including making opening water tight complete. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : 50mmNos1250.01250.06.0FalseNoneNoneFalseNoneFalse7500.00
3924896151381NoneMan400Providing and fixing 450mm puddle flanges inside walls of water tank including making opening water tight complete. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : 32mmNos900.0900.06.0FalseNoneNoneFalseNoneFalse5400.00
3924897151381NoneMan4011. Providing 12 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Water Proof Plastering Terrace and Coving) 2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (One Kg Bag of Cement) 3. Extra for making chequers of approved pattern on 1:2:4 cement concrete floors, steps, landing, pavements etc.Sqm409.53409.53265.0FalseNoneNoneFalseNoneFalse108525.450
3924898151381NoneMan4021. Providing 12 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Water Proof Plastering Terrace and Coving) 2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (One Kg Bag of Cement)Sqm351.78351.7820.0FalseNoneNoneFalseNoneFalse7035.60
3924899151381NoneMan403Providing and constructing SAUCER DRAIN : 1. Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works and super structure works of bridges upto 3.50 m height. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead and lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars and formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates 100mm ThickSqm1045.921045.9218.0FalseNoneNoneFalseNoneFalse18826.560
3924900151381NoneMan4041. Providing 15mm cement plaster onr ough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2. Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. [NOTE: Dosage at 1Kg per Bag of Cement] . For EXTERNAL PLASTERING: SUB STRUCTURESqm337.55337.55187.0FalseNoneNoneFalseNoneFalse63121.850
3924901151381NoneMan4051. Providing 12 mm cement plaster with cement mortar 1:3 (1 cement: 3 Fine sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (Water Proof Plastering Floor) 2. Extra for providing and mixing water proofing materials in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. [NOTE: Dosage at 1Kgs per Bag of Cement] (Water Proof Plastering FLOORS): SUB STRUCTURE (SEWAGE TREATMENT PLANT)Sqm349.77349.7761.0FalseNoneNoneFalseNoneFalse21335.970
3924902151381NoneMan406Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. For FLAGGINGSqm309.75309.7560.0FalseNoneNoneFalseNoneFalse18585.00
3924903151381NoneMan407Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works. (External Plastering)Sqm366.45366.4541.0FalseNoneNoneFalseNoneFalse15024.450
3924904151381NoneMan408DOORS, WINDOWS: and VENTILATORS: Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. RED SAL WOOD FRAMES.Cum104580.0104580.00.1FalseNoneNoneFalseNoneFalse10458.00
3924905151381NoneMan409Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.Nos1066.81066.81.0FalseNoneNoneFalseNoneFalse1066.80
3924906151381NoneMan410Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (partI) 1991. from manufacturer complete as per spcification. 40 mm thick both side TeakSqm4246.24246.23.0FalseNoneNoneFalseNoneFalse12738.60
3924907151381NoneMan411Providing and fixing of 3track x 2panel sliding windows made out of multi chambered UPVC(Matching to RAL9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardwareand Multi point locking system with touch lock. Wall thickness of frame and sash shall be of 2mm2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor TandP s shall not be made) PARTLY FIXED AND PARTLY SLIDING: GROUND FLOOR :Sqm7070.77070.713.0FalseNoneNoneFalseNoneFalse91919.10
3924908151381NoneMan4121. Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood) including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineerincharge.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. 2.Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge.Sqm176.4176.44.0FalseNoneNoneFalseNoneFalse705.60
3924909151381NoneMan413Providing and fixing 75mm thick 300 mm height and 1500 mm dia RCC ring with reinforcement using cement mortar 1:3 including all materials , labour , lead and lift, loading and unloading , scaffolding etc., complete including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.at all levelsNos1500.01500.040.0FalseNoneNoneFalseNoneFalse60000.00
3924910151381NoneMan414Gravel packing in tube well construction in accordance with IS: 4097, including providing gravel fine medium coarse, in required grading and sizes as per actual requirement, all complete as per direction of Engineerin charge.Cum1405.951405.955.0FalseNoneNoneFalseNoneFalse7029.750
3924911151381NoneMan415Supplying, filling, spreading and leveling broken bricks of size range 15 cm to 20 cm, in recharge pit, in the required thickness, for all leads and lifts, all complete as per direction of Engineerincharge.Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m including with all labour, all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools,plants and other incidental charges to the specification as per the directions of the engineer incharge of the works.Cum1200.01200.04.0FalseNoneNoneFalseNoneFalse4800.00
3924912151381NoneMan416Sand Filling in Wells complete as per Drawing and Technical Specifications. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.Cum2710.052710.053.0FalseNoneNoneFalseNoneFalse8130.150
3924913151381NoneMan417Providing and Filling in foundation with granite trap broken metal 100mm and down size with approved MSand including hand packing, ramming, watering including cost of all materials and labour with all lead and lift complete as per specifications.including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.Cum2816.12816.13.0FalseNoneNoneFalseNoneFalse8448.30
3924914151381NoneMan418Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead and lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4 : Pipes of SN4, 160mm dia.Rmtr604.8604.850.0FalseNoneNoneFalseNoneFalse30240.00
3924915151381NoneMan419Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead and lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN4 : Pipes of SN4, 110mm dia.Rmtr302.4302.450.0FalseNoneNoneFalseNoneFalse15120.00
3924916151381NoneMan420Providing and laying in Reinforced cement concrete for all Basement and surface level works, return walls, retaining walls, sunken floors etc. The granite trap basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead and lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement and Form Work to be paid separately) M 20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. [Cement 320 Kgs Cum]. Average 50 mm Thick.(Benching Concrete)Cum6639.156639.157.0FalseNoneNoneFalseNoneFalse46474.050
3924917151381NoneMan421FACADE WORK: Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. GROUND FLOOR:Kgs142.8142.82630.0FalseNoneNoneFalseNoneFalse375564.00
3924918151381NoneMan422Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. At ALL LEVELS:Kgs147.16147.1610500.0FalseNoneNoneFalseNoneFalse1545180.00
3924919151381NoneMan423Structural Glazing Work: Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved drawings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 6080 microns conforming to AAMA 2604 of required colour and shade as approved by the EngineerinCharge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.: Ground Floor:Kgs555.56555.562555.0FalseNoneNoneFalseNoneFalse1419455.80
3924920151381NoneMan424Structural Glazing Work: Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved drawings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 6080 microns conforming to AAMA 2604 of required colour and shade as approved by the EngineerinCharge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.: First Floor:Kgs561.12561.122590.0FalseNoneNoneFalseNoneFalse1453300.80
3924921151381NoneMan425Structural Glazing Work: Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved drawings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 6080 microns conforming to AAMA 2604 of required colour and shade as approved by the EngineerinCharge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.: Second Floor:Kgs566.73566.731540.0FalseNoneNoneFalseNoneFalse872764.20
3924922151381NoneMan426Structural Glazing Work: Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved drawings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 6080 microns conforming to AAMA 2604 of required colour and shade as approved by the EngineerinCharge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.: Third Floor:Kgs572.4572.41645.0FalseNoneNoneFalseNoneFalse941598.00
3924923151381NoneMan427Structural Glazing Work: Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved drawings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 6080 microns conforming to AAMA 2604 of required colour and shade as approved by the EngineerinCharge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.: Fourth Floor:Kgs578.12578.122870.0FalseNoneNoneFalseNoneFalse1659204.40
3924924151381NoneMan428Structural Glazing Work: Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved drawings of Chief Architect, GoK.The aluminium quality shall be as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 6080 microns conforming to AAMA 2604 of required colour and shade as approved by the EngineerinCharge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account).The weight of aluminium extruded section shall be taken for purpose of payment.: Fifth Floor:Kgs583.9583.94340.0FalseNoneNoneFalseNoneFalse2534126.00
3924925151381NoneMan429Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis and design and preparation of shop drawings for the specified design loads conforming to IS 875 part III This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, TandP, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineerincharge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer inCharge. (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)cumsmoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation and drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC masonry structural steel framework of building structure using stainless steel anchor fasteners bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c)Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d)Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.(e) Making provision for drainage of moisture water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. As per schedule B.Sqm3665.033665.03365.0FalseNoneNoneFalseNoneFalse1337735.950
3924926151381NoneMan430Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis and design and preparation of shop drawings for the specified design loads conforming to IS 875 part III This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, TandP, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineerincharge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer inCharge. (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)cumsmoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation and drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC masonry structural steel framework of building structure using stainless steel anchor fasteners bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c)Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d)Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.(e) Making provision for drainage of moisture water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. As per schedule B.Sqm3701.683701.68370.0FalseNoneNoneFalseNoneFalse1369621.60
3924927151381NoneMan431Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis and design and preparation of shop drawings for the specified design loads conforming to IS 875 part III. As per schedule B.Sqm3738.73738.7220.0FalseNoneNoneFalseNoneFalse822514.00
3924928151381NoneMan432Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis and design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)cumsmoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation and drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC masonry structural steel framework of building structure using stainless steel anchor fasteners bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c)Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d)Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.(e) Making provision for drainage of moisture water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, TandP, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineerincharge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer inCharge. As per schedule B.Sqm3776.093776.09235.0FalseNoneNoneFalseNoneFalse887381.150
3924929151381NoneMan433Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis and design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)cumsmoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation and drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC masonry structural steel framework of building structure using stainless steel anchor fasteners bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c)Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d)Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.(e) Making provision for drainage of moisture water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, TandP, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineerincharge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer inCharge. As per schedule B.Sqm3813.853813.85410.0FalseNoneNoneFalseNoneFalse1563678.50
3924930151381NoneMan434Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis and design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)cumsmoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation and drainage and protection against fire hazard including:(b) Fabricating and supplying serrated M.S. hot dip galvanised Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC masonry structural steel framework of building structure using stainless steel anchor fasteners bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c)Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d)Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight.(e) Making provision for drainage of moisture water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, TandP, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineerincharge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineer inCharge. As per schedule B.Sqm3851.993851.99620.0FalseNoneNoneFalseNoneFalse2388233.80
3924931151381NoneMan435Providing, assembling and supplying vision glass panels (IGUs) comprising of hermeticallysealed 612 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the EngineerinCharge. The IGUs shall be assembled in the factory workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient (0.250.28) and U value of 3.0 to 3.3 W m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Saint Gobain 6mm thick Green Aura Nebula Envision SKN 454 HS soft coated heat strengthened reflective glass outside and 6mm thick plain float glass toughened inside. Ground Floor:Sqm4153.74153.7364.0FalseNoneNoneFalseNoneFalse1511946.80
3924932151381NoneMan436Providing, assembling and supplying vision glass panels (IGUs) comprising of hermeticallysealed 612 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the EngineerinCharge. The IGUs shall be assembled in the factory workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient (0.250.28) and U value of 3.0 to 3.3 W m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Saint Gobain 6mm thick Green Aura Nebula Envision SKN 454 HS soft coated heat strengthened reflective glass outside and 6mm thick plain float glass toughened inside.: FIRST FLOOR:Sqm4195.244195.24370.0FalseNoneNoneFalseNoneFalse1552238.80
3924933151381NoneMan437Providing, assembling and supplying vision glass panels (IGUs) comprising of hermeticallysealed 612 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the EngineerinCharge. The IGUs shall be assembled in the factory workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient (0.250.28) and U value of 3.0 to 3.3 W m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Saint Gobain 6mm thick Green Aura Nebula Envision SKN 454 HS soft coated heat strengthened reflective glass outside and 6mm thick plain float glass toughened inside.:SECOND FLOOR:Sqm4237.194237.19220.0FalseNoneNoneFalseNoneFalse932181.80
3924934151381NoneMan438Providing, assembling and supplying vision glass panels (IGUs) comprising of hermeticallysealed 612 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the EngineerinCharge. The IGUs shall be assembled in the factory workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient (0.250.28) and U value of 3.0 to 3.3 W m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Saint Gobain 6mm thick Green Aura Nebula Envision SKN 454 HS soft coated heat strengthened reflective glass outside and 6mm thick plain float glass toughened inside.:THIRD FLOOR:Sqm4279.564279.56235.0FalseNoneNoneFalseNoneFalse1005696.60
3924935151381NoneMan439Providing, assembling and supplying vision glass panels (IGUs) comprising of hermeticallysealed 612 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the EngineerinCharge. The IGUs shall be assembled in the factory workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient (0.250.28) and U value of 3.0 to 3.3 W m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Saint Gobain 6mm thick Green Aura Nebula Envision SKN 454 HS soft coated heat strengthened reflective glass outside and 6mm thick plain float glass toughened inside.:FOURTH FLOOR:Sqm4322.364322.36410.0FalseNoneNoneFalseNoneFalse1772167.60
3924936151381NoneMan440Providing, assembling and supplying vision glass panels (IGUs) comprising of hermeticallysealed 612 6 mm insulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick, of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc. all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the EngineerinCharge. The IGUs shall be assembled in the factory workshop of the glass processor. (Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.18.2)For payment, only the actual area of glass on face 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2.(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient (0.250.28) and U value of 3.0 to 3.3 W m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Saint Gobain 6mm thick Green Aura Nebula Envision SKN 454 HS soft coated heat strengthened reflective glass outside and 6mm thick plain float glass toughened inside.: FIFTH FLOOR:Sqm4365.584365.58620.0FalseNoneNoneFalseNoneFalse2706659.60
3924937151381NoneMan441Extra for openable side top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : Ground Floor:Sqm5675.675675.6795.0FalseNoneNoneFalseNoneFalse539188.650
3924938151381NoneMan442Extra for openable side top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: First Floor:Sqm5732.435732.4395.0FalseNoneNoneFalseNoneFalse544580.850
3924939151381NoneMan443Extra for openable side top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: Second Floor:Sqm5789.755789.7555.0FalseNoneNoneFalseNoneFalse318436.250
3924940151381NoneMan444Extra for openable side top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: Third Floor:Sqm5847.655847.6560.0FalseNoneNoneFalseNoneFalse350859.00
3924941151381NoneMan445Extra for openable side top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: Fourth Floor:Sqm5906.135906.13105.0FalseNoneNoneFalseNoneFalse620143.650
3924942151381NoneMan446Extra for openable side top hung vision glass panels (IGUs) including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer inCharge. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.: Fifth Floor:Sqm5965.195965.19155.0FalseNoneNoneFalseNoneFalse924604.450
3924943151381NoneMan447Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi rigid, inorganic, noncombustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface 1 of the fibre glass insulation layer), of black nonwoven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g m2,made of randomly oriented glass fibres distributed in a binder by a wetlay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete.: Ground Floor:Sqm2646.742646.74265.0FalseNoneNoneFalseNoneFalse701386.10
3924944151381NoneMan448Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi rigid, inorganic, noncombustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface 1 of the fibre glass insulation layer), of black nonwoven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g m2,made of randomly oriented glass fibres distributed in a binder by a wetlay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete.: First Floor:Sqm2673.212673.21280.0FalseNoneNoneFalseNoneFalse748498.80
3924945151381NoneMan449Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi rigid, inorganic, noncombustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface 1 of the fibre glass insulation layer), of black nonwoven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g m2,made of randomly oriented glass fibres distributed in a binder by a wetlay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete.: Second Floor:Sqm2699.942699.94450.0FalseNoneNoneFalseNoneFalse1214973.00
3924946151381NoneMan450Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi rigid, inorganic, noncombustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface 1 of the fibre glass insulation layer), of black nonwoven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g m2,made of randomly oriented glass fibres distributed in a binder by a wetlay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete.: Third Floor:Sqm2726.942726.94435.0FalseNoneNoneFalseNoneFalse1186218.90
3924947151381NoneMan451Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi rigid, inorganic, noncombustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface 1 of the fibre glass insulation layer), of black nonwoven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g m2,made of randomly oriented glass fibres distributed in a binder by a wetlay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete.: Fourth Floor:Sqm2754.212754.21370.0FalseNoneNoneFalseNoneFalse1019057.70
3924948151381NoneMan452Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi rigid, inorganic, noncombustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface 1 of the fibre glass insulation layer), of black nonwoven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g m2,made of randomly oriented glass fibres distributed in a binder by a wetlay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete.: Fifth Floor:Sqm2781.752781.75215.0FalseNoneNoneFalseNoneFalse598076.250
3924949151381NoneMan453Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer in Charge. For payment, only the actual area of glass on face 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, having properties as visible Light transmittance (VLT) of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient (0.25 0.28) and U value of 3.0 to 3.3 W m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Saint Gobain 6mm thick Green Aura Nebula Envision SKN 454 HS soft coated heat strengthened reflective glass outside and 6mm thick plain float glass toughened inside.: Ground Floor:Sqm2702.72702.7265.0FalseNoneNoneFalseNoneFalse716215.50
3924950151381NoneMan454Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer in Charge. For payment, only the actual area of glass on face 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, having properties as visible Light transmittance (VLT) of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient (0.25 0.28) and U value of 3.0 to 3.3 W m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Saint Gobain 6mm thick Green Aura Nebula Envision SKN 454 HS soft coated heat strengthened reflective glass outside and 6mm thick plain float glass toughened inside.: First Floor:Sqm2729.732729.73280.0FalseNoneNoneFalseNoneFalse764324.40
3924951151381NoneMan455Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer in Charge. For payment, only the actual area of glass on face 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, having properties as visible Light transmittance (VLT) of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient (0.25 0.28) and U value of 3.0 to 3.3 W m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Saint Gobain 6mm thick Green Aura Nebula Envision SKN 454 HS soft coated heat strengthened reflective glass outside and 6mm thick plain float glass toughened inside.: Second Floor:Sqm2757.032757.03450.0FalseNoneNoneFalseNoneFalse1240663.50
3924952151381NoneMan456Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer in Charge. For payment, only the actual area of glass on face 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, having properties as visible Light transmittance (VLT) of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient (0.25 0.28) and U value of 3.0 to 3.3 W m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Saint Gobain 6mm thick Green Aura Nebula Envision SKN 454 HS soft coated heat strengthened reflective glass outside and 6mm thick plain float glass toughened inside.: Third Floor:Sqm2784.62784.6435.0FalseNoneNoneFalseNoneFalse1211301.00
3924953151381NoneMan457Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer in Charge. For payment, only the actual area of glass on face 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, having properties as visible Light transmittance (VLT) of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient (0.25 0.28) and U value of 3.0 to 3.3 W m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Saint Gobain 6mm thick Green Aura Nebula Envision SKN 454 HS soft coated heat strengthened reflective glass outside and 6mm thick plain float glass toughened inside.: Fourth Floor:Sqm2812.452812.45370.0FalseNoneNoneFalseNoneFalse1040606.50
3924954151381NoneMan458Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer in Charge. For payment, only the actual area of glass on face 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, having properties as visible Light transmittance (VLT) of 25 to 35 percent, Light reflection internal 10 to 15percent, light reflection external 10 to 20 percent, shading coefficient (0.25 0.28) and U value of 3.0 to 3.3 W m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. Saint Gobain 6mm thick Green Aura Nebula Envision SKN 454 HS soft coated heat strengthened reflective glass outside and 6mm thick plain float glass toughened inside.: Fifth Floor:Sqm2840.572840.57215.0FalseNoneNoneFalseNoneFalse610722.550
3924955151381NoneMan459Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick Rcc stone walls and coloumns beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick nonhalogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E11912 and clause B, S1, do as per ENT 135011sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Straight Portion: Ground Floor:Sqm5444.995444.99100.0FalseNoneNoneFalseNoneFalse544499.00
3924956151381NoneMan460Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick Rcc stone walls and coloumns beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick nonhalogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E11912 and clause B, S1, do as per ENT 135011sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Straight Portion: First Floor:Sqm5499.445499.44100.0FalseNoneNoneFalseNoneFalse549944.00
3924957151381NoneMan461Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick Rcc stone walls and coloumns beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick nonhalogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E11912 and clause B, S1, do as per ENT 135011sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Straight Portion: Second Floor:Sqm5554.435554.4395.0FalseNoneNoneFalseNoneFalse527670.850
3924958151381NoneMan462Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick Rcc stone walls and coloumns beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick nonhalogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E11912 and clause B, S1, do as per ENT 135011sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Straight Portion: Third Floor:Sqm5609.975609.9795.0FalseNoneNoneFalseNoneFalse532947.150
3924959151381NoneMan463Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick Rcc stone walls and coloumns beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick nonhalogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E11912 and clause B, S1, do as per ENT 135011sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Straight Portion: Fourth Floor:Sqm5666.075666.0795.0FalseNoneNoneFalseNoneFalse538276.650
3924960151381NoneMan464Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick Rcc stone walls and coloumns beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick nonhalogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E11912 and clause B, S1, do as per ENT 135011sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete For Straight Portion: Fifth Floor:Sqm5722.735722.73225.0FalseNoneNoneFalseNoneFalse1287614.250
3924961151381NoneMan465Design supply and installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (PartIII). The Suspended System held with Spider Fittings of SS316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS 316 Grade Stainless steel Spider and bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab beams by means of SS 316 Grade stainless steel brackets and Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener and anchor bolts, non staining weather sealants of approved make, Teflon nylon bushes and separators to prevent bimetallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion and seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter and in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof and dust proof. The rate shall include submission of all design, Engineering and shop drawing including getting approval from structural designer, labour, TandP, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : GROUND FLOOR:Sqm10854.4810854.48175.0FalseNoneNoneFalseNoneFalse1899534.00
3924962151381NoneMan466Design supply and installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (PartIII). The Suspended System held with Spider Fittings of SS316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS 316 Grade Stainless steel Spider and bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab beams by means of SS 316 Grade stainless steel brackets and Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener and anchor bolts, non staining weather sealants of approved make, Teflon nylon bushes and separators to prevent bimetallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion and seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter and in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof and dust proof. The rate shall include submission of all design, Engineering and shop drawing including getting approval from structural designer, labour, TandP, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works. : FIRST FLOOR:Sqm10963.0210963.02145.0FalseNoneNoneFalseNoneFalse1589637.90
3924963151381NoneMan467Providing, fabricating and fixing of Glazed canopy system as per detailed architectural drawing in required architectural profile as per approved shop drawings inclusive of glass panels as specified below, supporting system, subframe assembly profiles, accessories, necessary scaffolding staging, performance guarantee for a period of ten years as per approved format etc. complete as per manufacturer s specifications, approved shop drawings and as directed by the Engineer and as detailed hereunder : The supporting structure for canopy system shall be of MS hollow rectangular square tubular box sections conforming to IS 4923 or MS hot rolled single builtup sections conforming to IS : 2062 or medium heavy class MS hollow pipe sections conforming to IS: 1161 as approved by the Engineer. The joints of the rolled sections pipe junctions shall be welded as required with good quality of electrodes and finished smooth by grinding. The structural steel sections shall be finished with two coats of acrylic polyurethane painting over a coat of noncorrosive epoxy primer including surface preparation etc. The supporting structure shall be anchored with MS base plates MS angles to the main RCC steel structure using foundation plates and bolts or alternatively the members shall be embedded in the concrete wherever possible . The size of the glazed canopy panels shall be as specified in the detailed drawing or as approved by the Engineer. The length shall be made to order to minimize wastage. The Glass canopy will be fixed as per the detailed drawing. The entire system shall be completely water tight and shall include for colourless structural silicone sealants, weather seals, spacers, desiccants, fasteners, staging scaffolding etc. complete all as per approved shop drawings, technical specifications and as directed by the Engineer. Note : Structural Steel supporting system including painting over the steel sections shall be measured and paid separately. including with all lead, lifts and deflits, loading and unloading with all cost of material HOM of machinaries, tools, plants and other incidental charges to the specification as per the directions of the engineer in charge of the works.Sqm18850.018850.0110.0FalseNoneNoneFalseNoneFalse2073500.00
3924964151381NoneMan468Funder Max Specification: Providing and fixing in position 6mm thk Century Ply s high density prelaminated exterior Cladding material in elevation at all locations straight or segmented as per the design and fixed to the aluminum MS frame work anchored with appropriate size anchor bolts screws in approved manner including providing scaffolding for the errection of the frame work, all materials, labour, cutting as per design instructions of the consulting engineer and architects including scaffolding, all materials, labour etc., completeSqm7500.07500.0420.0FalseNoneNoneFalseNoneFalse3150000.00
3924965151381NoneMan469ELECTRICAL WORK: HT PANELS: DAS RMU DAS Specification Compact RMU (VCB SF6 Type) as per IEC62271. The DAS RMUs shall have the following in addition to the Standards: DC motors, Numerical Relays, Multifunctional meters, fault passage indicator (FPI), Metering CTs, Protection CTs, Auxiliary transformers, Potential transformer, Batteries, Battery chargers (12V and 24V), AC power socket and light for illumination of Control panel. Control cable from each panel shall be wired and terminated to suitable 24 pin connectors in the control panel. Suitable space for fixing the Remote Terminal Unit (RTU) and Radio Modem in Control panel. Suitable clamps for fixing Antenna Pipe 3 Way RMU, 2OD + 1VL (One Incomer + One Breakers + One Outgoing) 630A with Copper Bus Bar.Nos827661.45827661.451.0FalseNoneNoneFalseNoneFalse827661.450
3924966151381NoneMan470METERING CUBICLE 11 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT and 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem and 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification. (Dwg No. BESCOM GM QSandS ....Dtd 24.11.2018) NOTE: CONTRACTOR TO OPERATE THIS ITEM, ONLY IF ELECTRICITY BOARD DO NOT SUPPLY THE SAME.Nos255645.6255645.61.0FalseNoneNoneFalseNoneFalse255645.60
3924967151381NoneMan471HT PANEL Conventional RMU (VCB Type) with Copper Busbar, 350 MVA, 630 Amps as per IEC 62271 IS3427 One Breaker (VL) Panel with Copper BusbarNos489260.1489260.11.0FalseNoneNoneFalseNoneFalse489260.10
3924968151381NoneMan472TRANSFORMERS Distribution Transformer 3 Phase, 11kV 433V Amorphous Core with Oil as per IS1180 (Part1): 2014 500 kVA, Aluminium Wdg, Star 2 (5 Star)Nos1023084.31023084.32.0FalseNoneNoneFalseNoneFalse2046168.60
3924969151381NoneMan473HT CABLES Supplying and laying of high tension 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS7098 (Part2) Armouring wires dia and Resistivity as per IS3975.: 240 Sqmm, (55 GI Wires 3.15 mm Dia).Km2222957.12222957.10.2FalseNoneNoneFalseNoneFalse444591.420
3924970151381NoneMan474Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size: Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable: 3C x 240 Sq.mmNos7698.67698.61.0FalseNoneNoneFalseNoneFalse7698.60
3924971151381NoneMan475Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size: Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable : 3C x 240 Sq.mmNos5703.65703.612.0FalseNoneNoneFalseNoneFalse68443.20
3924972151381NoneMan476PARTB: LT ELECTRICAL WORK LT PANELS Supply, installation, testing and commissioning of cubicle type medium voltage switch boards as per specifications and comprising of ACB, MCCB, switch fuse unit etc., enclosed in M.S. cubicle complete with angle iron frame work, panel doors, horizontal and vertical busbars and outgoing feeders, bakelite separators, phase barriers, gaskets for door, feeders designations, etc., complete as per specifications. Main Switch Board shall be capable of withstanding 50 KA fault level. The panel shall be suitable for erection on the floor using channel and fastners at regular intervals. Fabricating supplying and mounting MS box made out ....SWG suitable for floor wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., 14 SWGSq CM0.530.5318000.0FalseNoneNoneFalseNoneFalse9540.00
3924973151381NoneMan477Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic FRP DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 100 A 4 x 30 x 6 mm Aluminium Strips Typical Lighting Floor Panel (Total 6 Nos) Basement Floor SMSB Panel 1 Nos Lift Panel 1 Nos UPS Panel 2 Nos (Total 10 Nos)Mtr2588.252588.2520.0FalseNoneNoneFalseNoneFalse51765.00
3924974151381NoneMan478Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic FRP DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 250 A 4 x 30 x 10 mm Aluminium Strips Typical Power Floor Panel (Total 6 Nos) As Incomer MUPS Panel 1 (Total 7 Nos)Mtr3606.753606.7512.0FalseNoneNoneFalseNoneFalse43281.00
3924975151381NoneMan479Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic FRP DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 400 A 4 x 50 x 10 mm Aluminium StripsMtr4667.254667.252.0FalseNoneNoneFalseNoneFalse9334.50
3924976151381NoneMan480Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic FRP DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 600 A 4 x 75 x 10 mm Aluminium Strips ACCP Panel 1 NosMtr5906.255906.252.0FalseNoneNoneFalseNoneFalse11812.50
3924977151381NoneMan481Supplying ......... A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic FRP DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete 1000 A double run of 4 x 60 x 10 mm Aluminium Strips LT Panel 1 NosMtr11109.011109.050.0FalseNoneNoneFalseNoneFalse555450.00
3924978151381NoneMan482Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 75 x 6 mmMtr582.75582.7560.0FalseNoneNoneFalseNoneFalse34965.00
3924979151381NoneMan483Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 75 x 150 x 75 x 6 mm C channel.Mtr972.3972.310.0FalseNoneNoneFalseNoneFalse9723.00
3924980151381NoneMan48411 kV CT : Indoor Outdoor.: 11 kV CT : 1200800 111 A (for Incomer Bus Coupler of 25 kA SWG) : OUTDOORNo59713.559713.52.0FalseNoneNoneFalseNoneFalse119427.00
3924981151381NoneMan48511 kV CT : Indoor Outdoor.: 11 kV CT : 800400 111 A (for Incomer Bus Coupler of 25 kA SWG ) : INDOORNo38115.038115.02.0FalseNoneNoneFalseNoneFalse76230.00
3924982151381NoneMan486Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON OFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5063 A TPN For TVSS ConnectivityEach3242.43242.41.0FalseNoneNoneFalseNoneFalse3242.40
3924983151381NoneMan487Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230 440VAC. 50 Hz 12 24V D.C.Each540.75540.7524.0FalseNoneNoneFalseNoneFalse12978.00
3924984151381NoneMan488Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel wood board.Each474.6474.64.0FalseNoneNoneFalseNoneFalse1898.40
3924985151381NoneMan489Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay auto manual reset facility suitable to mount on DIN rail flush mounting on panel board.Each9717.759717.754.0FalseNoneNoneFalseNoneFalse38871.00
3924986151381NoneMan490Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, kVA, kWH, kVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracyEach9780.759780.754.0FalseNoneNoneFalseNoneFalse39123.00
3924987151381NoneMan491Supplying, fixing and wiring rotary selector switch suitable for VoltmeterEach168.0168.02.0FalseNoneNoneFalseNoneFalse336.00
3924988151381NoneMan492Supplying, fixing and wiring 3 Phase Digital Ammeter VoltmeterEach1496.251496.254.0FalseNoneNoneFalseNoneFalse5985.00
3924989151381NoneMan493Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ON OFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. As Isolator 5063 A TPNNo3242.43242.42.0FalseNoneNoneFalseNoneFalse6484.80
3924990151381NoneMan494LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 10 Sqmm, 4 Core, (10 GI Strips 4 x 0.8 mm)Km156042.6156042.65.02FalseNoneNoneFalseNoneFalse783333.8520
3924991151381NoneMan495LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 25 Sqmm, 4 Core, (13 GI Strips 4 x 0.8 mm)Km252853.65252853.650.36FalseNoneNoneFalseNoneFalse91027.3140
3924992151381NoneMan496LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 50 Sqmm, 4 Core, (17 GI Strips 4 x 0.8 mm)Km311550.75311550.750.03FalseNoneNoneFalseNoneFalse9346.52250
3924993151381NoneMan497LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 95 Sqmm, 3.5 Core, (21 GI Strips 4 x 0.8 mm)Km539742.0539742.00.57FalseNoneNoneFalseNoneFalse307652.940
3924994151381NoneMan498LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 120 Sqmm, 3.5 Core, (23 GI Strips 4 x 0.8 mm)Km664451.55664451.550.65FalseNoneNoneFalseNoneFalse431893.50750
3924995151381NoneMan499LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 240 Sqmm, 3.5 Core, (30 GI Strips 4 x 0.8 mm)Km1245374.551245374.550.16FalseNoneNoneFalseNoneFalse199259.9280
3924996151381NoneMan500LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 25 Sqmm, 3.5 Core, (12 GI Strips 4 x 0.8 mm)Km190524.6190524.60.25FalseNoneNoneFalseNoneFalse47631.150
3924997151381NoneMan501LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.:50 Sqmm, 3.5 Core, (16 GI Strips 4 x 0.8 mm)Km254531.55254531.550.5FalseNoneNoneFalseNoneFalse127265.7750
3924998151381NoneMan502LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 70 Sqmm, 3.5 Core, (18 GI Strips 4 x 0.8 mm)Km444855.6444855.60.03FalseNoneNoneFalseNoneFalse13345.6680
3924999151381NoneMan503LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 95 Sqmm, 3.5 Core, (21 GI Strips 4 x 0.8 mm)Km539742.0539742.00.11FalseNoneNoneFalseNoneFalse59371.620
3925000151381NoneMan504LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 185 Sqmm, 3.5 Core, (28 GI Strips 4 x 0.8 mm)Km725778.9725778.90.06FalseNoneNoneFalseNoneFalse43546.7340
3925001151381NoneMan505LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 300 Sqmm, 3.5 Core, (32 GI Strips 4 x 0.8 mm)Km1119314.71119314.70.2FalseNoneNoneFalseNoneFalse223862.940
3925002151381NoneMan506LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 400 Sqmm, 3.5 Core, (39 GI Strips 4 x 0.8 mm)Km1526142.451526142.450.3FalseNoneNoneFalseNoneFalse457842.7350
3925003151381NoneMan507LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 3C 10 Sq.mm 2XWY (Copper)Km379000.0379000.00.01FalseNoneNoneFalseNoneFalse3790.00
3925004151381NoneMan508LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 2C 16 Sq.mm 2XWY (Copper)Km395000.0395000.00.21FalseNoneNoneFalseNoneFalse82950.00
3925005151381NoneMan509LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 1C 16 Sq.mm 2XWY (Copper)Km195000.0195000.00.14FalseNoneNoneFalseNoneFalse27300.00
3925006151381NoneMan510LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 4 C 6 Sq.mm (Copper)Km171517.5171517.50.11FalseNoneNoneFalseNoneFalse18866.9250
3925007151381NoneMan511LT CABLES Supply, laying and Installation commisioning 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 (Part 1) or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975approved make by making necessary connection, testing etc. as required.: 4 Core 10 Sq mm (Copper)Km280612.5280612.50.01FalseNoneNoneFalseNoneFalse2806.1250
3925008151381NoneMan5124C 16 Sq.mm. flexible multicore with copper conductor, PVC insulated, PVC shealthed CableMtr661.0661.0210.0FalseNoneNoneFalseNoneFalse138810.00
3925009151381NoneMan5134C 25Sq.mm. flexible multicore with copper conductor, PVC insulated, PVC shealthed CableMtr1133.01133.026.0FalseNoneNoneFalseNoneFalse29458.00
3925010151381NoneMan5141C 10 Sq.mm flexible single core cable with annealed copper conductor, PVC insulated, PVC unsheathed cableMtr96.096.05.0FalseNoneNoneFalseNoneFalse480.00
3925011151381NoneMan5151C 25 Sq.mm flexible single core cable with annealed copper conductor, PVC insulated, PVC unsheathed cableMtr235.0235.05.0FalseNoneNoneFalseNoneFalse1175.00
3925012151381NoneMan5161C 95 Sq.mm flexible single core cable with annealed copper conductor, PVC insulated, PVC unsheathed cableMtr894.0894.0231.0FalseNoneNoneFalseNoneFalse206514.00
3925013151381NoneMan517Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 81301984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS694:1990: 3C x 2.5 Sq.mm.Mtr118.65118.651103.0FalseNoneNoneFalseNoneFalse130870.950
3925014151381NoneMan518Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 81301984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS694:1990: 3C x 4 Sq.mm.Mtr180.6180.6788.0FalseNoneNoneFalseNoneFalse142312.80
3925015151381NoneMan51912 C - 2.5 Sq.mm YFY (Copper)Mtr350.0350.074.0FalseNoneNoneFalseNoneFalse25900.00
3925016151381NoneMan52024 C - 2.5 Sq.mm YFY (Copper)Mtr525.0525.0158.0FalseNoneNoneFalseNoneFalse82950.00
3925017151381NoneMan521LAYING CHARGES FOR CABLES Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe stoneware pipe on wall on pole as required. In existing trench duct. 2.5 sqmm to 25 sqmmKm21930.321930.34.96FalseNoneNoneFalseNoneFalse108774.2880
3925018151381NoneMan522LAYING CHARGES FOR CABLES Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe stoneware pipe on wall on pole as required. In existing trench duct. 35 sqmm to 95 sqmmKm32695.9532695.951.12FalseNoneNoneFalseNoneFalse36619.4640
3925019151381NoneMan523LAYING CHARGES FOR CABLES Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe stoneware pipe on wall on pole as required. In existing trench duct. 120 sqmm to 240 sqmmKm33891.933891.90.91FalseNoneNoneFalseNoneFalse30841.6290
3925020151381NoneMan524LAYING CHARGES FOR CABLES Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe stoneware pipe on wall on pole as required. In existing trench duct. 300sqmm 400 SqmmKm35884.835884.80.3FalseNoneNoneFalseNoneFalse10765.440
3925021151381NoneMan525END TERMINATION Supplying and making end termination with brass Double compression gland and Copper lugs for following size of PVC insulated and PVC sheathed XLPE aluminium conductor cable of 1.1 KV grade as required.: Heavy Duty Copper Terminal Long Barrel 3C 2.5 Sq.mmNos100.8100.830.0FalseNoneNoneFalseNoneFalse3024.00
3925022151381NoneMan526END TERMINATION Supplying and making end termination with brass Double compression gland and Copper lugs for following size of PVC insulated and PVC sheathed XLPE aluminium conductor cable of 1.1 KV grade as required.: Heavy Duty Copper Terminal Long Barrel 3C 4 Sq.mmNos110.25110.2540.0FalseNoneNoneFalseNoneFalse4410.00
3925023151381NoneMan527END TERMINATION Supplying and making end termination with brass Double compression gland and Copper lugs for following size of PVC insulated and PVC sheathed XLPE aluminium conductor cable of 1.1 KV grade as required.: Heavy Duty Copper Terminal Long Barrel 3C -6 Sq.mmNos93.4593.452.0FalseNoneNoneFalseNoneFalse186.90
3925024151381NoneMan528END TERMINATION Supplying and making end termination with brass Double compression gland and Copper lugs for following size of PVC insulated and PVC sheathed XLPE aluminium conductor cable of 1.1 KV grade as required.: Heavy Duty Copper Terminal Long Barrel 3C -10 Sq.mmNos113.4113.42.0FalseNoneNoneFalseNoneFalse226.80
3925025151381NoneMan529END TERMINATION Supplying and making end termination with brass Double compression gland and Copper lugs for following size of PVC insulated and PVC sheathed XLPE aluminium conductor cable of 1.1 KV grade as required.: Heavy Duty Copper Terminal Long Barrel 2C -16 Sq.mmNos148.97148.9716.0FalseNoneNoneFalseNoneFalse2383.520
3925026151381NoneMan530END TERMINATION Supplying and making end termination with brass Double compression gland and Copper lugs for following size of PVC insulated and PVC sheathed XLPE aluminium conductor cable of 1.1 KV grade as required.: Heavy Duty Copper Terminal Long Barrel 4 C -6 Sq.mmNos100.8100.8120.0FalseNoneNoneFalseNoneFalse12096.00
3925027151381NoneMan531END TERMINATION Supplying and making end termination with brass Double compression gland and Copper lugs for following size of PVC insulated and PVC sheathed XLPE aluminium conductor cable of 1.1 KV grade as required.: Heavy Duty Copper Terminal Long Barrel 4C 10 Sq.mm.Nos121.8121.880.0FalseNoneNoneFalseNoneFalse9744.00
3925028151381NoneMan532END TERMINATION Supplying and making end termination with brass Double compression gland and Copper lugs for following size of PVC insulated and PVC sheathed XLPE aluminium conductor cable of 1.1 KV grade as required.: Heavy Duty Copper Terminal Long Barrel 4C 16 Sq.mm.Nos175.1175.120.0FalseNoneNoneFalseNoneFalse3502.00
3925029151381NoneMan533Heavy Duty Copper Terminal Long Barrel: 25 Sqmm Copper Terminal, Apprx Wt: 11 Gm: 4CNos236.25236.2520.0FalseNoneNoneFalseNoneFalse4725.00
3925030151381NoneMan534Heavy Duty Copper Terminal Long Barrel: 50 Sqmm Copper Terminal, Apprx Wt: 26 Gm: 4CNos366.45366.4528.0FalseNoneNoneFalseNoneFalse10260.60
3925031151381NoneMan535Heavy Duty Copper Terminal Long Barrel: 70 Sqmm Copper Terminal, Apprx Wt: 38 Gm: 4CNos577.5577.52.0FalseNoneNoneFalseNoneFalse1155.00
3925032151381NoneMan536Heavy Duty Copper Terminal Long Barrel: 95 Sqmm Copper Terminal, Apprx Wt: 58 Gm: 4CNos745.5745.518.0FalseNoneNoneFalseNoneFalse13419.00
3925033151381NoneMan537Heavy Duty Copper Terminal Long Barrel: 120 Sqmm Copper Terminal, Apprx Wt: 64 Gm: 4CNos855.75855.7512.0FalseNoneNoneFalseNoneFalse10269.00
3925034151381NoneMan538Heavy Duty Copper Terminal Long Barrel: 185 Sqmm Copper Terminal, Apprx Wt: 158 Gm: 4CNos1279.951279.952.0FalseNoneNoneFalseNoneFalse2559.90
3925035151381NoneMan539Heavy Duty Copper Terminal Long Barrel: 240 Sqmm Copper Terminal, Apprx Wt: 218 Gm: 3.5CNos1898.41898.44.0FalseNoneNoneFalseNoneFalse7593.60
3925036151381NoneMan540Heavy Duty Copper Terminal Long Barrel: 300 Sqmm Copper Terminal : 3.5CNos2683.82683.812.0FalseNoneNoneFalseNoneFalse32205.60
3925037151381NoneMan541Heavy Duty Copper Terminal Long Barrel: 400 Sqmm Copper Terminal, Apprx Wt: 395 Gm : 3 1/2 CNos4637.854637.856.0FalseNoneNoneFalseNoneFalse27827.10
3925038151381NoneMan542Aluminium End Terminal (Lug): 10 Sq.mm : 1 CNos90.390.320.0FalseNoneNoneFalseNoneFalse1806.00
3925039151381NoneMan543Aluminium End Terminal (Lug): 16 Sq.mm : 1 CNos90.390.340.0FalseNoneNoneFalseNoneFalse3612.00
3925040151381NoneMan544Aluminium End Terminal (Lug): 95 Sq.mm : 1 CNos219.45219.4518.0FalseNoneNoneFalseNoneFalse3950.10
3925041151381NoneMan54512 C -2.5 Sq.mm YFY (Copper)Nos107.44107.444.0FalseNoneNoneFalseNoneFalse429.760
3925042151381NoneMan54624 C -2.5 Sq.mm YFY (Copper)Nos144.88144.884.0FalseNoneNoneFalseNoneFalse579.520
3925043151381NoneMan547CABLE TRAY (PERFORATED TYPE) Supplying and installing 2 mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts nuts and washer or welding as required. etc with all accessories like bends, reducers, Tee s, cross members, etc. complete as required. 150 x 50 mmMtr486.15486.15473.0FalseNoneNoneFalseNoneFalse229948.950
3925044151381NoneMan548CABLE TRAY (PERFORATED TYPE) Supplying and installing 2 mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts nuts and washer or welding as required. etc with all accessories like bends, reducers, Tee s, cross members, etc. complete as required. 300 x 50 mmMtr616.35616.35200.0FalseNoneNoneFalseNoneFalse123270.00
3925045151381NoneMan549CABLE TRAY (LADDER TYPE) Supply and erection of the following sizes of prefabricated, factory assembled, bottled rung type ladder trays made out of 2mm thick Pre galvanised steel runners and slotted rungs at every 300mm interval, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc with all accessories like bends, reducers, Tee s, cross members, etc. complete as required. 150 mm x 50mmMtr270.0270.0420.0FalseNoneNoneFalseNoneFalse113400.00
3925046151381NoneMan550CABLE TRAY (LADDER TYPE) Supply and erection of the following sizes of prefabricated, factory assembled, bottled rung type ladder trays made out of 2mm thick Pre galvanised steel runners and slotted rungs at every 300mm interval, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc with all accessories like bends, reducers, Tee s, cross members, etc. complete as required. 250 mm x 50mmMtr375.0375.0158.0FalseNoneNoneFalseNoneFalse59250.00
3925047151381NoneMan551CABLE TRAY (LADDER TYPE) Supply and erection of the following sizes of prefabricated, factory assembled, bottled rung type ladder trays made out of 2mm thick Pre galvanised steel runners and slotted rungs at every 300mm interval, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc with all accessories like bends, reducers, Tee s, cross members, etc. complete as required. 300 mm x 50mmMtr430.0430.0131.0FalseNoneNoneFalseNoneFalse56330.00
3925048151381NoneMan552CABLE TRAY (LADDER TYPE) Supply and erection of the following sizes of prefabricated, factory assembled, bottled rung type ladder trays made out of 2mm thick Pre galvanised steel runners and slotted rungs at every 300mm interval, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc with all accessories like bends, reducers, Tee s, cross members, etc. complete as required. 450 mm x 75mmMtr475.0475.026.0FalseNoneNoneFalseNoneFalse12350.00
3925049151381NoneMan553CABLE TRAY (LADDER TYPE) Supply and erection of the following sizes of prefabricated, factory assembled, bottled rung type ladder trays made out of 2mm thick Pre galvanised steel runners and slotted rungs at every 300mm interval, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc with all accessories like bends, reducers, Tee s, cross members, etc. complete as required. 600 mm x 75mmMtr962.0962.063.0FalseNoneNoneFalseNoneFalse60606.00
3925050151381NoneMan554MCB and MCCB Distribution BoardS, MCCB, MCB and ELMCB Supplying and fixing regular MCB distribution boards on wall ood board flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB s single phase 3 phase single door with powder coated painting Made out of 14 SWG MS enclosure. 8 Way SPN MCB DBNos1566.61566.614.0FalseNoneNoneFalseNoneFalse21932.40
3925051151381NoneMan555MCB and MCCB Distribution BoardS, MCCB, MCB and ELMCB Supplying and fixing regular MCB distribution boards on wall ood board flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB s single phase 3 phase single door with powder coated painting Made out of 14 SWG MS enclosure. 12 Way SPN MCB DBNos1956.151956.1515.0FalseNoneNoneFalseNoneFalse29342.250
3925052151381NoneMan556MCB and MCCB Distribution BoardS, MCCB, MCB and ELMCB Supplying and fixing regular MCB distribution boards on wall ood board flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB s single phase 3 phase single door with powder coated painting Made out of 14 SWG MS enclosure. 16 Way SPN MCB DBNos3078.63078.623.0FalseNoneNoneFalseNoneFalse70807.80
3925053151381NoneMan557MCB and MCCB Distribution BoardS, MCCB, MCB and ELMCB Supplying and fixing regular MCB distribution boards on wall ood board flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB s single phase 3 phase single door with powder coated painting Made out of 14 SWG MS enclosure. 4 Way TPN MCB DBNos4239.94239.91.0FalseNoneNoneFalseNoneFalse4239.90
3925054151381NoneMan558MCB and MCCB Distribution BoardS, MCCB, MCB and ELMCB Supplying and fixing regular MCB distribution boards on wall ood board flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB s single phase 3 phase single door with powder coated painting Made out of 14 SWG MS enclosure. 6 Way TPN MCB DBNos5187.05187.015.0FalseNoneNoneFalseNoneFalse77805.00
3925055151381NoneMan559MCB and MCCB Distribution BoardS, MCCB, MCB and ELMCB Supplying and fixing regular MCB distribution boards on wall ood board flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB s single phase 3 phase single door with powder coated painting Made out of 14 SWG MS enclosure. 8 Way TPN MCB DBNos6395.556395.5515.0FalseNoneNoneFalseNoneFalse95933.250
3925056151381NoneMan560Supplying and fixing regular MCCB distribution Panel confirming to IS IEC 61439 3 and IK09 tested as per IS IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall wood board flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB s as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single three phase suitable capacity MCB s as outgoings confirming to IS IEC 60898 2.. 8WAYNos13235.2513235.251.0FalseNoneNoneFalseNoneFalse13235.250
3925057151381NoneMan561Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick Stone C.C wall : 1 2 WayNos144.9144.917.0FalseNoneNoneFalseNoneFalse2463.30
3925058151381NoneMan562Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal PVC box.: 1 2 ModulaNos143.85143.8517.0FalseNoneNoneFalseNoneFalse2445.450
3925059151381NoneMan563Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as perIS IEC609472.(Icu=100percentlcs). In 4P MCCB, all Poles should have protection for ShortCicrcuit Over Load. For Microprocessor MCCB S Facility for segregating Priority and NonPriority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multipole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR Pole 100 A 25 kA 1. Typical Lighting Floor Panel(Total 6 Nos) As Incomer 1 Nos 6 Nos. 2. Basement Floor SMSB Panel As Incomer 1 Nos. 3. Lift Panel As Incomer and Out Going 2 Nos. 4. LT Panel Out going Floor Lighting Panel 6 Nos ,PHE , STP, SMSB 1 Basement Floor,Lift Panel 10 Nos. 5. LT Panel Out going Spare 3 Nos.Nos8911.358911.3522.0FalseNoneNoneFalseNoneFalse196049.70
3925060151381NoneMan564Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as perIS IEC609472.(Icu=100percentlcs). In 4P MCCB, all Poles should have protection for ShortCicrcuit Over Load. For Microprocessor MCCB S Facility for segregating Priority and NonPriority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multipole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 125 A 25 kA 1. ACCP Panel As Out goings 2 Nos. 2. MUPS Panel 1 Nos. 3. LT Panel Out going Spare 1 Nos.Nos10858.0510858.054.0FalseNoneNoneFalseNoneFalse43432.20
3925061151381NoneMan565Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as perIS IEC609472.(Icu=100percentlcs). In 4P MCCB, all Poles should have protection for ShortCicrcuit Over Load. For Microprocessor MCCB S Facility for segregating Priority and NonPriority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multipole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 160 A 25 kA 1. LT Panel Out going Floor Power Panel 6 Nos and Fire Fighting Panel 7 Nos. 2. LT Panel Out going Spare1 Nos. 3. Typical Power Floor Panel(Total 6 Nos) As Incomer 1 Nos 6 Nos.Nos14119.3514119.3514.0FalseNoneNoneFalseNoneFalse197670.90
3925062151381NoneMan566Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as perIS IEC609472.(Icu=100percentlcs). In 4P MCCB, all Poles should have protection for ShortCicrcuit Over Load. For Microprocessor MCCB S Facility for segregating Priority and NonPriority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multipole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 250 A 25 kA 1. HVAC Panel as Incomer 1 Nos.Nos22460.5522460.551.0FalseNoneNoneFalseNoneFalse22460.550
3925063151381NoneMan567Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as perIS IEC609472.(Icu=100percentlcs). In 4P MCCB, all Poles should have protection for ShortCicrcuit Over Load. For Microprocessor MCCB S Facility for segregating Priority and NonPriority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multipole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 200 A 36 kA 1. LT Panel Out going AC1,2,3 3 Nos. 2. LT Panel Out going UPS 1 and 2 2 Nos. 3. LT Panel Out going Spare 2 Nos.Nos22495.222495.27.0FalseNoneNoneFalseNoneFalse157466.40
3925064151381NoneMan568Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as perIS IEC609472.(Icu=100percentlcs). In 4P MCCB, all Poles should have protection for ShortCicrcuit Over Load. For Microprocessor MCCB S Facility for segregating Priority and NonPriority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multipole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 250 A 36 kA 1. LT Panel Out going HVAC Panel 1 Nos.Nos24722.2524722.251.0FalseNoneNoneFalseNoneFalse24722.250
3925065151381NoneMan569Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as perIS IEC609472.(Icu=100percentlcs). In 4P MCCB, all Poles should have protection for ShortCicrcuit Over Load. For Microprocessor MCCB S Facility for segregating Priority and NonPriority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multipole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 400 A 36 kA 1. ACCP Panel As Incomer 1 Nos.Nos29626.829626.81.0FalseNoneNoneFalseNoneFalse29626.80
3925066151381NoneMan570Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as perIS IEC609472.(Icu=100percentlcs). In 4P MCCB, all Poles should have protection for ShortCicrcuit Over Load. For Microprocessor MCCB S Facility for segregating Priority and NonPriority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multipole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 320400 A 50 kA 1. DG Incomer to Breaker Panel and Outgoings to LT Panel 5 Nos. 2. LT Panel Out going ACCP Panel 1 Nos.Nos31616.5531616.556.0FalseNoneNoneFalseNoneFalse189699.30
3925067151381NoneMan571Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit with adjustable thermal magnetic release, Microprocessor release shall have Earth Fault as perIS IEC609472.(Icu=100percentlcs). In 4P MCCB, all Poles should have protection for ShortCicrcuit Over Load. For Microprocessor MCCB S Facility for segregating Priority and NonPriority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multipole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 400500 A 50 kA 1. ACCP Panel As Out goingsNos43571.8543571.851.0FalseNoneNoneFalseNoneFalse43571.850
3925068151381NoneMan572Supplying and fixing of Shunt trip suitable for MCCB.CBCT 1. Basement Floor SMSB Panel As Out goingsNos1788.151788.153.0FalseNoneNoneFalseNoneFalse5364.450
3925069151381NoneMan573RCCBs: Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240 450V upto 300mA sensitivity on existing wood panel board. 16A25A 2 poleNos4490.854490.8533.0FalseNoneNoneFalseNoneFalse148198.050
3925070151381NoneMan574RCCBs: Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240 450V upto 300mA sensitivity on existing wood panel board. 3240A 2 poleNos4786.954786.9526.0FalseNoneNoneFalseNoneFalse124460.70
3925071151381NoneMan575RCCBs: Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240 450V upto 300mA sensitivity on existing wood panel board. 63 A 2 poleNos5520.95520.93.0FalseNoneNoneFalseNoneFalse16562.70
3925072151381NoneMan576RCCBs: Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240 450V upto 300mA sensitivity on existing wood panel board. 1625A 4 poleNos5319.35319.31.0FalseNoneNoneFalseNoneFalse5319.30
3925073151381NoneMan577Supply and fixing of 3pole Capacitor switching contactor with NO NC contacts and inbuilt damping resistor to protect the contactor and capacitor from highest in rush current, fixed on existing wood panel board using necessary bolts, nuts, washers and wiring etc., complete with AC690V Rating operational voltage, 50HZ frequency and as per IS 6094741. 12.5 KVAR: ACCP PanelNos3046.053046.054.0FalseNoneNoneFalseNoneFalse12184.20
3925074151381NoneMan578Supply and fixing of 3pole Capacitor switching contactor with NO NC contacts and inbuilt damping resistor to protect the contactor and capacitor from highest in rush current, fixed on existing wood panel board using necessary bolts, nuts, washers and wiring etc., complete with AC690V Rating operational voltage, 50HZ frequency and as per IS 6094741. 30 KVAR : ACCP PanelNos5527.25527.21.0FalseNoneNoneFalseNoneFalse5527.20
3925075151381NoneMan579Supply and fixing of 3pole Capacitor switching contactor with NO NC contacts and inbuilt damping resistor to protect the contactor and capacitor from highest in rush current, fixed on existing wood panel board using necessary bolts, nuts, washers and wiring etc., complete with AC690V Rating operational voltage, 50HZ frequency and as per IS 6094741. 50 KVAR : ACCP PanelNos15820.3515820.352.0FalseNoneNoneFalseNoneFalse31640.70
3925076151381NoneMan580SUB MAIN CIRCUIT CIRCUIT MAINS Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.0 Sq.mmMtr19.9519.955000.0FalseNoneNoneFalseNoneFalse99750.00
3925077151381NoneMan581Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 Sq.mmMtr27.327.37000.0FalseNoneNoneFalseNoneFalse191100.00
3925078151381NoneMan582Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 2.5 Sq.mmMtr44.144.117000.0FalseNoneNoneFalseNoneFalse749700.00
3925079151381NoneMan583Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 Sq.mmMtr66.1566.1520000.0FalseNoneNoneFalseNoneFalse1323000.00
3925080151381NoneMan584Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 6 Sq.mmMtr96.696.68000.0FalseNoneNoneFalseNoneFalse772800.00
3925081151381NoneMan585Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 10 Sq.mmMtr175.35175.35250.0FalseNoneNoneFalseNoneFalse43837.50
3925082151381NoneMan586Supplying heavy gauge PVC Conduit Pipe....dia.......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hook sand cement plastering upto the wall surface and run with18SWG GI fish wire run throughout the conduit wherever necessary. 19 20mm dia 2mm thickMtr71.471.413500.0FalseNoneNoneFalseNoneFalse963900.00
3925083151381NoneMan587Supplying heavy gauge PVC Conduit Pipe....dia.......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hook sand cement plastering upto the wall surface and run with 18SWG GI fish wire run throughout the conduit wherever necessary. 25mm dia 2mm thickMtr82.9582.9520000.0FalseNoneNoneFalseNoneFalse1659000.00
3925084151381NoneMan588Supplying heavy gauge PVC Conduit Pipe....dia.......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hook sand cement plastering upto the wall surface and run with18SWG GI fish wire run throughout the conduit wherever necessary. 32mm dia 2.5mm thickMtr103.95103.959750.0FalseNoneNoneFalseNoneFalse1013512.50
3925085151381NoneMan589Supplying heavy gauge PVC Conduit Pipe....dia.......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hook sand cement plastering upto the wall surface and run with18SWG GI fish wire run throughout the conduit wherever necessary. 40mm dia 2.5mm thickMtr145.95145.95200.0FalseNoneNoneFalseNoneFalse29190.00
3925086151381NoneMan590OPEN CONDUIT SYSTEM Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19 20 mm dia 2 mm thick.Mtr72.4572.455000.0FalseNoneNoneFalseNoneFalse362250.00
3925087151381NoneMan591OPEN CONDUIT SYSTEM Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25 mm dia 2 mm thick.Mtr85.0585.051450.0FalseNoneNoneFalseNoneFalse123322.50
3925088151381NoneMan592OPEN CONDUIT SYSTEM Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 32 mm dia 2.5mm thick.Mtr111.3111.3350.0FalseNoneNoneFalseNoneFalse38955.00
3925089151381NoneMan593OPEN CONDUIT SYSTEM Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 40 mm dia 2.5mm thick.Mtr156.45156.4575.0FalseNoneNoneFalseNoneFalse11733.750
3925090151381NoneMan594Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 19 20 mm dia 2 mm thickMtr69.369.315000.0FalseNoneNoneFalseNoneFalse1039500.00
3925091151381NoneMan595Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 25 mm dia 2 mm thick.Mtr81.981.918000.0FalseNoneNoneFalseNoneFalse1474200.00
3925092151381NoneMan596Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 32 mm dia 2.5mm thick.Mtr108.15108.151000.0FalseNoneNoneFalseNoneFalse108150.00
3925093151381NoneMan597Concealed Conduit System Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 40 mm dia 2.5mm thick.Mtr154.35154.351000.0FalseNoneNoneFalseNoneFalse154350.00
3925094151381NoneMan598POINT WIRING: PRIMARY POINT (Long Points) Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2x1.5 Sqmm (PhaseandNeutral) and 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS694: and latest amendments) without control switch shall be fixed on the existing plastic sheet gang box ,the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to outlet via switch box Note: 1) Rates for all the point wiring items are inclusive of necessary circuit mains from the distribution board to the first switch board and also sub circuits from one switch board to the subsequent switch boards in the same circuit. 2) All the Chases made in the wall, ceiling, etc., at the time of laying of conduits shall be filled up neatly after erection of conduit.Point582.75582.751300.0FalseNoneNoneFalseNoneFalse757575.00
3925095151381NoneMan599SECONDARY POINT (MEDIUM POINT) Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2x1.5 Sqmm (PhaseandNeutral) and 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS694: and latest amendments) without control switch shall be fixed on the existing plastic sheet gang box ,the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch box Note: 1) Rates for all the point wiring items are inclusive of necessary circuit mains from the distribution board to the first switch board and also sub circuits from one switch board to the subsequent switch boards in the same circuit. 2) All the Chases made in the wall, ceiling, etc., at the time of laying of conduits shall be filled up neatly after erection of conduit.No397.95397.951000.0FalseNoneNoneFalseNoneFalse397950.00
3925096151381NoneMan600SECONDARY POINT (Short Points) Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2x1.5 Sqmm (PhaseandNeutral) and 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS694: and latest amendments) without control switch shall be fixed on the existing plastic sheet gang box ,the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box Note: 1) Rates for all the point wiring items are inclusive of necessary circuit mains from the distribution board to the first switch board and also sub circuits from one switch board to the subsequent switch boards in the same circuit. 2) All the Chases made in the wall, ceiling, etc., at the time of laying of conduits shall be filled up neatly after erection of conduit.No282.45282.45250.0FalseNoneNoneFalseNoneFalse70612.50
3925097151381NoneMan601Supplying and fixing PVC metal conduit Deep junction box 19 20 mm deep Junction boxNo51.4551.45900.0FalseNoneNoneFalseNoneFalse46305.00
3925098151381NoneMan602SECONDARY POINT (Short Points) Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2x1.5 Sqmm (PhaseandNeutral) and 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS694: and latest amendments) without control switch shall be fixed on the existing plastic sheet gang box ,the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box Note: 1) Rates for all the point wiring items are inclusive of necessary circuit mains from the distribution board to the first switch board and also sub circuits from one switch board to the subsequent switch boards in the same circuit. 2) All the Chases made in the wall, ceiling, etc., at the time of laying of conduits shall be filled up neatly after erection of conduit. Supplying and fixing PVC metal conduit Deep junction box 25 mm deep Junction boxNo58.858.8800.0FalseNoneNoneFalseNoneFalse47040.00
3925099151381NoneMan603SECONDARY POINT (Short Points) Supplying and wiring adopting loop system in existing PVC Conduit casing capping casing capping using 2x1.5 Sqmm (PhaseandNeutral) and 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS694: and latest amendments) without control switch shall be fixed on the existing plastic sheet gang box ,the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box Note: 1) Rates for all the point wiring items are inclusive of necessary circuit mains from the distribution board to the first switch board and also sub circuits from one switch board to the subsequent switch boards in the same circuit. 2) All the Chases made in the wall, ceiling, etc., at the time of laying of conduits shall be filled up neatly after erection of conduit. Supplying and fixing PVC metal conduit Deep junction box 32 mm deep Junction boxNo64.0564.05800.0FalseNoneNoneFalseNoneFalse51240.00
3925100151381NoneMan604CEILING FAN POINT Supplying of Ceiling Fan with Capacitor rating As per guide line of BEE 5 star rating and IS:374 19 and also comply with IS:1709 1984 with latest amendment, Rated voltage 220V 50Hz, Rated power upto 35W+ 10percent, Rated current As per IS:374 19, Rated power factor 0.9 lagging (min), Rated speed 350+ 10percentRPM, Ratedairdelivery210+ 10percentCubicMeter Minimum, Rated service value 6.2 CMM W, Three Blades of blade leaf 1.05mm thick Aluminium Alloy sheet, ClassB motor insulation, Bearing Two ball bearings, Top6202, Bottom6201, as per IS specification, Motor winding. Temprise Shall not exceed 75deg Cover and ambient of 400C by resistance method at 245V, Insulation resistance Shall not be less than Two Mega Ohms (2MOhms), Leakage current Should not exceed 210Micro Amp, Power input, Wandcurrent, Air Delivery and Fan Speed as per IS:374 2019 with latest amendment, 2 year manufacturer Warranty. (BLDC fans) 48inches Sweep 5 Star (1200 mm) Note: In case of roof slab MS rod inchesUinches hooks shall be provided in place of fan hook box.No2810.852810.8570.0FalseNoneNoneFalseNoneFalse196759.50
3925101151381NoneMan605Fixing a ceiling Wall mounting fan of all capacities and all types to the existing Sinches hook with fan regulator to the existing board to gether with supplying and fixing 5A. ceiling rose, necessary length of 23 0.0076 inch PVC insulated twin twisted copper wire and wiring.Each179.55179.55105.0FalseNoneNoneFalseNoneFalse18852.750
3925102151381NoneMan606EXHAUST FAN POINT Supplyingof1440rpmheavydutyexhaustfanwithbracketbladessuitable to operate on 230V 50Hz, AC Supply complete. 12inches Sweep (300 mm)No3117.453117.4511.0FalseNoneNoneFalseNoneFalse34291.950
3925103151381NoneMan607Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5A, ceiling rose with sufficient length of 23 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.Each742.35742.3511.0FalseNoneNoneFalseNoneFalse8165.850
3925104151381NoneMan608TWO WAY STAIRCASE LIGHT POINT Supplying and fixing of modular switch and connected accessories on existing modular switch plate as per IS 3854 and IS 1293.No174.3174.315.0FalseNoneNoneFalseNoneFalse2614.50
3925105151381NoneMan609BUZZER POINT Supplying And fixing replacing of 6 16 32A electrical accessories on existing switch board. 6A Bell BuzzerNo136.5136.510.0FalseNoneNoneFalseNoneFalse1365.00
3925106151381NoneMan610SWITCHES, SOCKETS and ACCESSORIES: Supplying and fixing surface flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick C.C wall, including necessary rawl plugs, Machine NF screws etc., complete. 12 WayNo108.15108.1510.0FalseNoneNoneFalseNoneFalse1081.50
3925107151381NoneMan611SWITCHES, SOCKETS and ACCESSORIES: Supplying and fixing surface flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick C.C wall, including necessary rawl plugs, Machine NF screws etc., complete. 3 WayNo130.2130.250.0FalseNoneNoneFalseNoneFalse6510.00
3925108151381NoneMan612SWITCHES, SOCKETS and ACCESSORIES: Supplying and fixing surface flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick C.C wall, including necessary rawl plugs, Machine NF screws etc., complete. 45 WayNo143.85143.8575.0FalseNoneNoneFalseNoneFalse10788.750
3925109151381NoneMan613SWITCHES, SOCKETS and ACCESSORIES: Supplying and fixing surface flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick C.C wall, including necessary rawl plugs, Machine NF screws etc., complete. 6 WayNo181.65181.6575.0FalseNoneNoneFalseNoneFalse13623.750
3925110151381NoneMan614SWITCHES, SOCKETS and ACCESSORIES: Supplying and fixing surface flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick C.C wall, including necessary rawl plugs, Machine NF screws etc., complete. 8 WayNo229.95229.95100.0FalseNoneNoneFalseNoneFalse22995.00
3925111151381NoneMan615SWITCHES, SOCKETS and ACCESSORIES: Supplying and fixing surface flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick C.C wall, including necessary rawl plugs, Machine NF screws etc., complete. 1012 WayNo274.05274.05100.0FalseNoneNoneFalseNoneFalse27405.00
3925112151381NoneMan616SWITCHES, SOCKETS and ACCESSORIES: Supplying and fixing surface flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick C.C wall, including necessary rawl plugs, Machine NF screws etc., complete. 16 WayNo308.7308.7100.0FalseNoneNoneFalseNoneFalse30870.00
3925113151381NoneMan617SWITCHES, SOCKETS and ACCESSORIES: Supplying and fixing surface flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick C.C wall, including necessary rawl plugs, Machine NF screws etc., complete. 18 WayNo355.95355.9520.0FalseNoneNoneFalseNoneFalse7119.00
3925114151381NoneMan618Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick Stone C.C wall. 12 WayNo144.9144.910.0FalseNoneNoneFalseNoneFalse1449.00
3925115151381NoneMan619Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick Stone C.C wall. 3 WayNo166.95166.9550.0FalseNoneNoneFalseNoneFalse8347.50
3925116151381NoneMan620Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick Stone C.C wall. 4 5 WayNo185.85185.8575.0FalseNoneNoneFalseNoneFalse13938.750
3925117151381NoneMan621Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick Stone C.C wall. 6 WayNo231.0231.075.0FalseNoneNoneFalseNoneFalse17325.00
3925118151381NoneMan622Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick Stone C.C wall. 8 WayNo274.05274.05100.0FalseNoneNoneFalseNoneFalse27405.00
3925119151381NoneMan623Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick Stone C.C wall. 1012 WayNo334.95334.95100.0FalseNoneNoneFalseNoneFalse33495.00
3925120151381NoneMan624Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick Stone C.C wall. 16 WayNo381.15381.15100.0FalseNoneNoneFalseNoneFalse38115.00
3925121151381NoneMan625Supplying and flush mounting powder coated galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick Stone C.C wall. 18 WayNo425.25425.2520.0FalseNoneNoneFalseNoneFalse8505.00
3925122151381NoneMan6266A One Way SwitchNo107.1107.1700.0FalseNoneNoneFalseNoneFalse74970.00
3925123151381NoneMan6276A Two Way SwitchNo174.3174.320.0FalseNoneNoneFalseNoneFalse3486.00
3925124151381NoneMan6286 16A Universal SocketNo247.8247.8500.0FalseNoneNoneFalseNoneFalse123900.00
3925125151381NoneMan629TV Telephone SocketNo163.8163.8100.0FalseNoneNoneFalseNoneFalse16380.00
3925126151381NoneMan630RJ45 I.O Outlet Cat6No353.85353.8550.0FalseNoneNoneFalseNoneFalse17692.50
3925127151381NoneMan6316A Bell PushNo185.85185.8525.0FalseNoneNoneFalseNoneFalse4646.250
3925128151381NoneMan632Supplying and fixing modular blanking plate on the existing modular plate and switch box excluding modular plate as required.No42.042.0188.0FalseNoneNoneFalseNoneFalse7896.00
3925129151381NoneMan633WIRE WAYS and RACEWAYS Supply and laying of under floor junction boxes shall be of threepiece construction -Base box, frame and load plate. Base box shall be robust in its construction manufactured from 1.5 mm thick zero spangle pre galvanized sheet steel with 275 GSM ( 36.67 microns) coating mass. The load plate and frame thicknesses shall be 3 mm and 2 mm respectively to provide adequate load bearing capacity of 5 kN with deflection not greater than 6mm while loading and permanent deflection not exceeding 3 mm as per EN 5008522. The trap and frame shall be Epoxy coated to protect from corrosion. The junction boxes shall be 10 mm or 20 mm recess to accommodate floor covering suitable for Tile Carpet marble granite according to site conditions. The junction box has height of 60mm up to finished floor level. The base of junction boxes should have prepunched sealing arrangements on all four sides to accept either 25 mm or 38 mm of metal raceways. For (50100x38mm) duct. Dimensions: 172x172x60mm. 10 mm RecessMtr1822.81822.810.0FalseNoneNoneFalseNoneFalse18228.00
3925130151381NoneMan634WIRE WAYS and RACEWAYS Supply and laying of of RFT raised floor trunking systemJunction, for raised Flooring For (50100x38mm) duct. Dimensions: 170 mm x 170 mm x 56mmMtr1376.551376.5510.0FalseNoneNoneFalseNoneFalse13765.50
3925131151381NoneMan635Supply and laying of underfloor (concealed) raceways manufactured from 1.5 mm thick cover and base (including partitions for multi compartment raceways), zero spangle pregalvanized sheet steel with 275 GSM ( 36.67 microns) coating mass, cover and base MIG welded together. the length of raceways shall be 2.5 meters per length with single accessories acting as duct connector including fastening clamps and vertical access boxes and with all required connected accessories complete and load bearing capacity in line with EN 5008522. 50 x 38mmMtr662.55662.5575.0FalseNoneNoneFalseNoneFalse49691.250
3925132151381NoneMan636Supply and laying of underfloor (concealed) raceways manufactured from 1.5 mm thick cover and base (including partitions for multi compartment raceways), zero spangle pregalvanized sheet steel with 275 GSM ( 36.67 microns) coating mass, cover and base MIG welded together. the length of raceways shall be 2.5 meters per length with single accessories acting as duct connector including fastening clamps and vertical access boxes and with all required connected accessories complete and load bearing capacity in line with EN 5008522. 100 x 38mmMtr937.65937.65150.0FalseNoneNoneFalseNoneFalse140647.50
3925133151381NoneMan637Supply and laying of underfloor (concealed) raceways manufactured from 1.5 mm thick cover and base (including partitions for multi compartment raceways), zero spangle pregalvanized sheet steel with 275 GSM ( 36.67 microns) coating mass, cover and base MIG welded together. the length of raceways shall be 2.5 meters per length with single accessories acting as duct connector including fastening clamps and vertical access boxes and with all required connected accessories complete and load bearing capacity in line with EN 5008522. 150 x 38mmMtr1587.61587.6150.0FalseNoneNoneFalseNoneFalse238140.00
3925134151381NoneMan638Supply and laying of underfloor (concealed) raceways manufactured from 1.5 mm thick cover and base (including partitions for multi compartment raceways), zero spangle pregalvanized sheet steel with 275 GSM ( 36.67 microns) coating mass, cover and base MIG welded together. the length of raceways shall be 2.5 meters per length with single accessories acting as duct connector including fastening clamps and vertical access boxes and with all required connected accessories complete and load bearing capacity in line with EN 5008522. 200 x 38mmMtr2268.02268.026.0FalseNoneNoneFalseNoneFalse58968.00
3925135151381NoneMan639Supply and laying of underfloor (concealed) raceways manufactured from 1.5 mm thick cover and base (including partitions for multi compartment raceways), zero spangle pregalvanized sheet steel with 275 GSM ( 36.67 microns) coating mass, cover and base MIG welded together. the length of raceways shall be 2.5 meters per length with single accessories acting as duct connector including fastening clamps and vertical access boxes and with all required connected accessories complete and load bearing capacity in line with EN 5008522. 300 x 38mmMtr3213.03213.068.0FalseNoneNoneFalseNoneFalse218484.00
3925136151381NoneMan640Supply and Installation of pregalvanised factory made junction boxes with 3.15mm thick cover plate and with counter sunk type screws of following sizes. The JBs Side plates shall be suitable for fixing metal and PVC raceways and knockouts to fit 20 25 32mm conduit entry. For (50100x38mm) duct.Dimensions:172x172x60mm. 10 mm RecessNo1822.81822.8100.0FalseNoneNoneFalseNoneFalse182280.00
3925137151381NoneMan641Supply and Installation of pregalvanised factory made junction boxes with 3.15mm thick cover plate and with counter sunk type screws of following sizes. The JBs Side plates shall be suitable for fixing metal and PVC raceways and knockouts to fit 20 25 32mm conduit entry. For (50200x38mm) duct.Dimensions:272x272x60mm. 10 mm RecessNo2678.552678.55150.0FalseNoneNoneFalseNoneFalse401782.50
3925138151381NoneMan642Supply and Installation of pregalvanised factory made junction boxes with 3.15mm thick cover plate and with counter sunk type screws of following sizes. The JBs Side plates shall be suitable for fixing metal and PVC raceways and knockouts to fit 20 25 32mm conduit entry. For (50300x38mm) duct.Dimensions:372x372x60mm. 10 mm RecessNo3696.03696.0100.0FalseNoneNoneFalseNoneFalse369600.00
3925139151381NoneMan643SUPPLY and INSTALLATION OF LIGHT FIXTURES Supply, fixing, wiring and Installation commisioning LED light fitting with driver having efficiency 85percent and in compliance to IEC standards suitable for continuous operation with THD 10percent, power factor 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. The fittings shall be made from die Cast aluminum housing, Heat sink for heat dissipation, high purity reflector, lumen efficeancy of 70 lm Watt output. Fixture shall be CE compliance. Supplying of ......feet PVC Batten with integrated LED tube.....W with high quality diffuser with Life of 25000 burning hours and 70percent lumen maintenance with CRI 80. Power Input: 220240V at 50 60Hz and Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x 2 9 10w (Similar to Wipro make Trim Neo LED LL20111XXX65NE3).Nos578.55578.5547.0FalseNoneNoneFalseNoneFalse27191.850
3925140151381NoneMan644SUPPLY and INSTALLATION OF LIGHT FIXTURES Supply, fixing, wiring and Installation commisioning LED light fitting with driver having efficiency 85percent and in compliance to IEC standards suitable for continuous operation with THD 10percent, power factor 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. The fittings shall be made from die Cast aluminum housing, Heat sink for heat dissipation, high purity reflector, lumen efficeancy of 70 lm Watt output. Fixture shall be CE compliance. Supplying of ......feet PVC Batten with integrated LED tube.....W with high quality diffuser with Life of 25000 burning hours and 70percent lumen maintenance with CRI 80. Power Input: 220240V at 50 60Hz and Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4 20 22 w (Similar to Wipro make Trim Neo LED LL20221XXX65NE3).Nos724.5724.5478.0FalseNoneNoneFalseNoneFalse346311.00
3925141151381NoneMan645SUPPLY and INSTALLATION OF LIGHT FIXTURES Supply, fixing, wiring and Installation commisioning LED light fitting with driver having efficiency 85percent and in compliance to IEC standards suitable for continuous operation with THD 10percent, power factor 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. The fittings shall be made from die Cast aluminum housing, Heat sink for heat dissipation, high purity reflector, lumen efficeancy of 70 lm Watt output. Fixture shall be CE compliance. Supplying of ......feet PVC Batten with integrated LED tube.....W with high quality diffuser with Life of 25000 burning hours and 70percent lumen maintenance with CRI 80. Power Input: 220240V at 50 60Hz and Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. Fixing all types and all capacities of 1 x4 2 x2 LED Light fittings indoor on the wall ceiling rafters girders with necessary supporting frame, using 2310.0076inches twin twisted PVC insulated wires, required Nos of round blocks and clamps.Each514.5514.5525.0FalseNoneNoneFalseNoneFalse270112.50
3925142151381NoneMan646Supplying of recess mounting non integral type ........LED ...... W luminaire comprising of pressure diecast extruded aluminium housing, with spring loaded fase ceiling clamps,Power LEDs with CCT 6500 degree K, CRI 70percent. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322 IEC 60598, LM 79 and LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5percent of lamp wattage., short circuit and open circuit protection to be integrated in the circuit, , THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. a) LED Down light 1518W (Similar to Wipro make Elate CRCO10S038HP57GL1).Nos1754.551754.55100.0FalseNoneNoneFalseNoneFalse175455.00
3925143151381NoneMan647Supplying of recess mounting non integral type ........LED ...... W luminaire comprising of pressure diecast extruded aluminium housing, with spring loaded fase ceiling clamps,Power LEDs with CCT 6500 degree K, CRI 70percent. efficacy 100 lumen per watt, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322 IEC 60598, LM 79 and LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5percent of lamp wattage., short circuit and open circuit protection to be integrated in the circuit, , THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. b) LED Down light 24 W (Similar to Wipro make Elate CRCO10S038HP57GL1).Nos1819.651819.65105.0FalseNoneNoneFalseNoneFalse191063.250
3925144151381NoneMan648Supplying of Recess Surface mounting non integrated type LED down light...... W luminaire comprising of pressure decast extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power COB with CCT 6500 degree K, CRI 70percent. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS10322 IEC 60598, LM 79 and LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED s are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5percent of lamp Wage, short circuit and open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical Condition. 1) 56W (Similar to Wipro make Garnet D650640 D640640).Nos845.25845.25158.0FalseNoneNoneFalseNoneFalse133549.50
3925145151381NoneMan649Supplying of Recess Surface mounting non integrated type LED Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power COB with CCT 6500 degree K, CRI 70percent. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS10322 IEC 60598, LM 79 and LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED s are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5percent of lamp Wage, short circuit and open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical Condition. 2) LED 10 12 watts (Similar to wipro Garnet DN D731040 Surface D641240).Nos1332.451332.45683.0FalseNoneNoneFalseNoneFalse910063.350
3925146151381NoneMan650Supplying of Recess Surface mounting non integrated type LED down light...... W luminaire comprising of pressure decast extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power COB with CCT 6500 degree K, CRI 70percent. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS10322 IEC 60598, LM 79 and LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED s are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5percent of lamp Wage, short circuit and open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical Condition. 3) LED 15 18 watts (Similar to wipro Garnet DN D731540 Surface D641840).Nos1754.551754.55252.0FalseNoneNoneFalseNoneFalse442146.60
3925147151381NoneMan651Supplying of Recess Surface mounting non integrated type LED down light...... W luminaire comprising of pressure decast extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power COB with CCT 6500 degree K, CRI 70percent. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS10322 IEC 60598, LM 79 and LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED s are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5percent of lamp Wage, short circuit and open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical Condition. 3) 24 W watts Similar to wipro Halo DN CRDL11R033HP57** Surface Vertica LD3030136B40SSNos1819.651819.6547.0FalseNoneNoneFalseNoneFalse85523.550
3925148151381NoneMan652Supply of LED FLOOD LIGHT luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percent, CCT 5500K, IP 66 optical and electrical compartment and impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltage Overload, short circuit misswiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50 60Hz application. Compliance to IS 10322 IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency 1301m w, nominal CRI 75. Luminaire manufacturer should have in house facility accredited by NABL CPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008. Housing with supplier word mark name shall be Engraved Embossing on the die cast housing Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and Cree Nichia Lumileds Osram make LED Source.: Recess Mounted 150W LED Flood light : Squash Table Tennis. Similar to Wipro LH 14 192XXX57G2Nos13114.513114.524.0FalseNoneNoneFalseNoneFalse314748.00
3925149151381NoneMan653Supply of LED FLOOD LIGHT luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percent, CCT 5500K, IP 66 optical and electrical compartment and impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltage Overload, short circuit misswiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50 60Hz application. Compliance to IS 10322 IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency 1301m w, nominal CRI 75. Luminaire manufacturer should have in house facility accredited by NABL CPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008. Housing with supplier word mark name shall be Engraved Embossing on the die cast housing Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and Cree Nichia Lumileds Osram make LED Source.: Recess Mounted 180W LED Flood light : (badminton Enterence Terrace). Similar to Wipro LF2019206057G2Nos16237.216237.244.0FalseNoneNoneFalseNoneFalse714436.80
3925150151381NoneMan654Supply of LED FLOOD LIGHT luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percent, CCT 5500K, IP 66 optical and electrical compartment and impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltage Overload, short circuit misswiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50 60Hz application. Compliance to IS 10322 IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System Power consumption. LED Efficiency 1301m w, nominal CRI 75. Luminaire manufacturer should have in house facility accredited by NABL CPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008. Housing with supplier word mark name shall be Engraved Embossing on the die cast housing Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and Cree Nichia Lumileds Osram make LED Source.: Recess Mounted 240W LED Flood light : (Multi Purpose Hall). Similar to wipro LF2034206057G2Nos23171.423171.436.0FalseNoneNoneFalseNoneFalse834170.40
3925151151381NoneMan655LED Post Top Lantern GARDEN.: Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate clear glass material, delivering superior light outputRated life Burning Hrs 50000 hr at Lumen Maintenance of 70percent, CCT 5500K, IP 66 optical and electrical compartment and impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltage Overload, short circuit misswiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50 60Hz application. Compliance to IS 10322 1 EC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB LED Efficiency 1301m w, nominal CRI 75. Luminaire manufacturer should have in house facility accredited by NABL CPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008. Housing with supplier word mark name shall be Engraved Embossing on the die cast housing Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and Cree Nichia Lumileds Osram make LED Source.: LED Post Top Lantern with 35 40 W (Similar to Wipro make LP07431XXX57CL)Nos10103.110103.129.0FalseNoneNoneFalseNoneFalse292989.90
3925152151381NoneMan656Supply of LED Bollard light fitting of ...W with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate clear glass material, delivering superior light output. Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percent, CCT 5500K, IP 66 optical and electrical compartment and impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection Min 5KV along with Over voltage Overload, short circuit misswiring protection. Universal Voltage driver to operate wide voltage range from 100V to 270V 50 60Hz application. Compliance to IS 10322 IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB, with 2 years Warranty against any manufacturing defect working under standard electrical condition.: 8W 1 Mtr Height (Similar to Wipro make Whistling Oyster LB12131XXX6508).Nos4755.44755.411.0FalseNoneNoneFalseNoneFalse52309.40
3925153151381NoneMan657Supplying and fixing of LED Bulk head of 10W with IP65 protection and IK 08 impact resistance suitable for surface and wall mounting applications. (similar to Wipro Make Moon Squre Round)Each884.1884.132.0FalseNoneNoneFalseNoneFalse28291.20
3925154151381NoneMan658Supplying and fixing of retrofit type LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70percent. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322 IEC 60598, LM 79 and LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5percent of lamp Wage., short circuit and open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.: 18W, 6500K ( Similar to Wipro Make GCF 30128).Each447.3447.32.0FalseNoneNoneFalseNoneFalse894.60
3925155151381NoneMan659Supplying and fixing of retrofit type LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70percent. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322 IEC 60598, LM 79 and LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5percent of lamp Wage., short circuit and open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.: 3 W 6500K: (Similar to Wipro Make Garnet D110327).Each130.2130.22.0FalseNoneNoneFalseNoneFalse260.40
3925156151381NoneMan660Supply of round square recess surface mounted rolling type LED Down light with ...... W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powder coated prewired to mains connector and has swivelling unit of aluminium die cast eye ball and LED Lamp position retained by circular wire spring, with Life of 25000 burning hours and 70percent lumen maintenance with CRI 80. Power Input: 220240V at50 60Hz and Power factor 0.9 along with CE approved. 2years Warranty against any manufacturing defect working under standard electrical conditiondriver, etc. with all necessary accessories as required complete (auditorium): LED square or round down light 56W. (Similar to Wipro Make Garnet Step Light)Nos599.55599.5532.0FalseNoneNoneFalseNoneFalse19185.60
3925157151381NoneMan661Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power COB with CCT 6500 degree K, CRI 70percent. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS10322 IEC 60598, LM 79 and LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED s are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5percent of lamp Wage, short circuit and open circuit protection to be integrated in the circuit, THD less than 20percent, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical. : 1012W: (Similar to Flos make Ares Leila 536016)Nos1332.451332.4532.0FalseNoneNoneFalseNoneFalse42638.40
3925158151381NoneMan662FIXING OF LIGHT FIXTURES Fixing all types and all capacities of 1 x4 2 x2 LED Light fittings indoor on the wall ceiling rafters girders with necessary supporting frame, using 2310.0076inches twin twisted PVC insulated wires, required Nos of round blocks and clamps. a) On wall ceiling Rafter GirdersEach514.5514.51589.0FalseNoneNoneFalseNoneFalse817540.50
3925159151381NoneMan663CHEMICAL EARTHING : For body application Supplying and Fixing Chemical earthling for grounding. Conduits, IC cutouts and other equipments backfill compound which is noncorrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance and capable of achieving ohmic value less than one ohm : Using 10ft. Copper bonded rod with backfill compoundKit8918.78918.730.0FalseNoneNoneFalseNoneFalse267561.00
3925160151381NoneMan664CHEMICAL GEL EARTHING : For NEUTRAL APPLICATION Supplying and Fixing Chemical earthling for grounding. Conduits, IC cutouts and other equipments backfill compound which is noncorrosive, thermally conductive, potential to permissible limits, superior Fault conduction capacity, non toxic, weather resistance and capable of achieving ohmic value less than one ohm : Using 10ft. SS rod with backfill compoundKit6541.56541.511.0FalseNoneNoneFalseNoneFalse71956.50
3925161151381NoneMan665EARTHING CONDUCTORS GI Copper strips for grounding connections, using necessary fixing materials as required: 50 x 6 mm GI stripRmtr228.9228.9236.0FalseNoneNoneFalseNoneFalse54020.40
3925162151381NoneMan666EARTHING CONDUCTORS GI Copper strips for grounding connections, using necessary fixing materials as required: 40 x 6 mm GI stripRmtr190.05190.05368.0FalseNoneNoneFalseNoneFalse69938.40
3925163151381NoneMan667EARTHING CONDUCTORS GI Copper strips for grounding connections, using necessary fixing materials as required: 25 x 6 mm GI stripRmtr134.4134.41680.0FalseNoneNoneFalseNoneFalse225792.00
3925164151381NoneMan668Providing and fixing 8 SWG dia G.I. wire on surface or in recess for loop earthing as required.Rmtr19.9519.955.0FalseNoneNoneFalseNoneFalse99.750
3925165151381NoneMan669Providing and fixing 25 x 6 mm Copper strip on surface or in recess for connections etc. as required.Rmtr1155.01155.05.0FalseNoneNoneFalseNoneFalse5775.00
3925166151381NoneMan670Providing and fixing 25 x 3 mm Copper strip on surface or in recess for connections etc. as required.Rmtr598.5598.5168.0FalseNoneNoneFalseNoneFalse100548.00
3925167151381NoneMan671Providing and fixing 40 x 6 mm Copper strip on surface or in recess for connections etc. as required.Rmtr1725.151725.15168.0FalseNoneNoneFalseNoneFalse289825.20
3925168151381NoneMan672Providing and fixing 8 SWG dia Cu. wire on surface or in recess for loop earthing as required.Rmtr110.25110.25105.0FalseNoneNoneFalseNoneFalse11576.250
3925169151381NoneMan673Coil Earthing: Providing and Errection of spiral earthing using 8 SWG GI wire for street light pole etc. The GI wire shall be buried to a minimum depth of 1.5 m, with excavation, refilling of earth and connecting GI wire to pole using GI bolt and nut complete as per drawing no. CED ELE S 5 and complete as required.Nos250.95250.9550.0FalseNoneNoneFalseNoneFalse12547.50
3925170151381NoneMan674MISELANEOUS ITEMS Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. Angle iron 40 x 40 x 6 mmMtr320.25320.25250.0FalseNoneNoneFalseNoneFalse80062.50
3925171151381NoneMan675MISELANEOUS ITEMS Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. Angle iron 50 x 50 x 6 mmMtr414.75414.75125.0FalseNoneNoneFalseNoneFalse51843.750
3925172151381NoneMan676Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. In Hard SoilCum354.9354.920.0FalseNoneNoneFalseNoneFalse7098.00
3925173151381NoneMan677Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. Hard Rock Latterite Rock latterite SoilCum1273.651273.65150.0FalseNoneNoneFalseNoneFalse191047.50
3925174151381NoneMan678Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 MtrCum60.960.9113.9FalseNoneNoneFalseNoneFalse6936.510
3925175151381NoneMan679Spreading and forming with sand all round the cable to a depth of 75 mm and width of 500 mm. (Does not include cost of sand).Km12148.512148.51.0FalseNoneNoneFalseNoneFalse12148.50
3925176151381NoneMan680Supplying of SandCum1549.81549.840.0FalseNoneNoneFalseNoneFalse61992.00
3925177151381NoneMan681Providing and laying Table Moulded Bricks as per the norms.Cum5500.05500.030.0FalseNoneNoneFalseNoneFalse165000.00
3925178151381NoneMan682Fabricating, supplying and erection of …Mtrs long hot dip Galvanized Octagonal pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47 m sec for …….Mtrs pole in single section and single joint welded as per IS 9595 IS 10178AWS having dimensions bottom …..mm, top….mm with 3mm thick, suitable base plate and 4Nos of ..... long J bolts along with template and the pole shall be hot dip galvanized in single dipping with not less than 65micron as per ASTMA123 and 153 etc., (excluding foundation) as per drawing appended.: 3meters Top 70mm and bottom 130mm diaEach6615.06615.028.0FalseNoneNoneFalseNoneFalse185220.00
3925179151381NoneMan683Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole wall drain crossing with necessary clamping arrangements for UG cable of 1.1 KV class. (a) 50 mm diaMtr650.0650.010.0FalseNoneNoneFalseNoneFalse6500.00
3925180151381NoneMan684Supply, Installation and commissioning of 8mm dia Aluminum Solid Round Conductor for building terrace as a air terminal and down condcutor as per required LPL, to meet the requirements for IS IEC 62305. Tested for Electrical Resistivity test (0.0293 ) as per IEC 62561 1and 2, Mechanical Load Test (216 Mpa) as per IEC 62561 2 and Salt Mist Test at 628 hrs with No sign of corrosion as per IEC 62561 2 and IEC 60068.2.52. The rate shall include required conductor holders (including suitable for truss), Cross Connectors, Straight Connectors, Expansion Piece with connector, etc. with all accessories complete as required. Similar to CAPE SRC 8 -ALMtr189.0189.0665.0FalseNoneNoneFalseNoneFalse125685.00
3925181151381NoneMan685Supply of 3000mm Vertical Airterminal of dia 1610 mm with Complete Support of 3no wall clamp selected as per angle of protection chart to meet the requirement of IS IEC 62305 .Tested for Electrical ,Mechanical and Chemical as per IEC 62561. CAPE Type: VATW3Nos6404.06404.07.0FalseNoneNoneFalseNoneFalse44828.00
3925182151381NoneMan686Supply of Lightning counter LCD screen shows the number of lightning strikes, hour and date of lightning events Buttons enable TIME DATE setting and log viewing. Replaceable battery, working life minimum five years, Complies with IEC EN 625616. CAPE Type: PRO LEC BasicNos41017.041017.01.0FalseNoneNoneFalseNoneFalse41017.00
3925183151381NoneMan687Supply of Stainless Steel Test Joint with enclosure to interconnect between 8 mm Al. round conductor to 10 mm copper bonded round conductor or 40x6 GI strip, Test Parameter:Salt Spray Test for test joint plate No sign of Corrosion Tested as per IEC 625611No1687.01687.020.0FalseNoneNoneFalseNoneFalse33740.00
3925184151381NoneMan688TEST LINK Test links as per specification grouted to wall at 1200mm above ground level complete with all fixing accessories etc., as required completeNo380.0380.014.0FalseNoneNoneFalseNoneFalse5320.00
3925185151381NoneMan689RUBBER MAT Supply of PVC grade Electrical insulation mat suitable for voltage rating upto 3.3 kV , confirming to IS: 15652:2006 with latest amendment , class A with thickness of 2 mm + 10percent, ISI marked complete as required.Mtr1768.01768.010.0FalseNoneNoneFalseNoneFalse17680.00
3925186151381NoneMan690Supplying and installing of CO22 Kgs capacity Fire Extinguishers for multipurpose (Servers, Panels, Computers, etc.). a) 4.5 ltre Kg.Each4810.04810.08.0FalseNoneNoneFalseNoneFalse38480.00
3925187151381NoneMan691Supplying of Two Bucket stand along with Buckets.Each630.0630.01.0FalseNoneNoneFalseNoneFalse630.00
3925188151381NoneMan692Supplying of HAND GLOVES.Pair170.0170.01.0FalseNoneNoneFalseNoneFalse170.00
3925189151381NoneMan693Supplying of First Aid Box.Kit215.0215.01.0FalseNoneNoneFalseNoneFalse215.00
3925190151381NoneMan694Supplying of First Aid Shock treatment Chart with Lamination.Each225.0225.01.0FalseNoneNoneFalseNoneFalse225.00
3925191151381NoneMan695Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required.Each585.0585.020.0FalseNoneNoneFalseNoneFalse11700.00
3925192151381NoneMan696Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.Each141.0141.01.0FalseNoneNoneFalseNoneFalse141.00
3925193151381NoneMan697PARTC: DG SET AND ALLIED WORKS DIESEL GENERATOR SET : Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating as per standard reference condition as perBS 5514 ISO 3046 ISO 8528 and IS 1002 ISO 3046 Generator set specifications. Engine: Diesel generating set are rated at 1500RPM and conform to ISO 8528 specifications. The engines are radiator cooled, four stroke and multi cylinder, conforming to ISO 3046. The scope of supply includes: Electrical starter motor12V DC Battery charging alternator, Bosch fuel system with mechanical governor, A1 Class. Spinon lube oil filter, Spinon dual fuel filter with water separator, Turbocharger, Charge air cooler, Silencer (Hospital grade), Dry type air cleaner, Shutoff coil, Flywheel and flywheel housing, First fill of lube oil and coolant, Safety for low lube oil pressure, Safety for high water temperature, Permissible overload of 10percent for one hour in 12 hours of operation, Capacity of Fuel Tank: Fuel tank suitable for 8 hours of operation. Alternator: Alternator is suitable for operation at 1500 RPM, 415 V, 0.8 pf (lag) suitable for 50 Hz, 3 phase, 4 wire systems, conforming to IS IEC 600341. The Alternator is brush less type, screen protected, revolving field, self excited, self regulated through an AVR. The alternator shall have 1.0 percent Voltage regulation (max) in static conditions IP: 23 protections with insulation class FandH Mounting arrangement: Engine and alternator are mounted on a common MS fabricated base frame with AVM pads. Control Panel: The control panel is manufactured with 14 16 gauge CRCA sheet and is powder coated for weatherproof and long lasting finish. The control panel consists of the following parts: PS0500 Controller, Aluminium bus bars with suitable capacity within outgoing terminals, Indicating lA for Load On and Set Running , Instrument fuses duly wired and ferruled, MCCB of suitable rating with overload and short circuit protections. As per schedule B.Set1999537.051999537.051.0FalseNoneNoneFalseNoneFalse1999537.050
3925194151381NoneMan698Supply, Erection, testing and commissioning of AMF panel suitable for .....kVA DG set. The panel is of cubical type base floor mounting control panel with hinged doors, undrilled bottom gland plate, aluminium Bus Bar with the accommodation for .....A 4 pole contactor for alternator with thermal O L relay,..... A 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor based AMF module with supply failure timer, Restoration timer, 3 impulse automatic engine start stop logic, Mains generator voltage, ....capacity bypass switch and frequency sensing, PCC 1301controller with water temperature Lube oil pressure engine speed, Voltage ampere Frequency kVA, Runninghour count, No of starts, Fault indication, over under speed, Fails to start, Low oil pleasure, High engine temperature, Under over voltage, over current, Earth fault relay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMF module by pass Mode, Battery charger unit with inbuilt Auto Manual and Flat Boost facility. The complete set shall have sufficient safety and adhere to NEC, NBC 2016, IEC, CPWD specifications, PCB norms and KSGEI Acts and Rules. 250 KVAEach295100.4295100.41.0FalseNoneNoneFalseNoneFalse295100.40
3925195151381NoneMan699Exhaust System (JOB WORK) Supply, receive at site, store, unpack, assemble and connect exhaust pipe with Class B MS pipe with flanges, fire fly gaskets, hardware, mineral wool and aluminium sheet cladding etc., as per specification inclusive of all supports of wall, ceiling, etc., complete as required. Individual Exhaust pipe including flexibles from set with mineral wool and Alu. clading etc., as required complete for 250 KVA DG set (diameter of the pipe shall be specified by the vendor) as per local norms.Mtr5500.05500.090.0FalseNoneNoneFalseNoneFalse495000.00
3925196151381NoneMan700Supplying and fixing of 75 MM thick, mineral wool insulation (of 150 Kg. Per cubic metre density) over the exhaust pipes of following diameter including cladding with aluminium sheet of 26 SWG and covering from outside complete, as required.Mtr575.0575.0100.0FalseNoneNoneFalseNoneFalse57500.00
3925197151381NoneMan701Supporting work for exhaust system Steel work as required to support the exhaust system. Related civil works shall be included. Painting with two coats of primer and two coats of approved enamel paint.Kgs138.0138.05000.0FalseNoneNoneFalseNoneFalse690000.00
3925198151381NoneMan702Lightning arrestor Vertical air termination.Nos3700.03700.01.0FalseNoneNoneFalseNoneFalse3700.00
3925199151381NoneMan703Supply, erection and testing of LED type Aviation obstruction light of comprising of cast aluminium housing with polycarbonate enclosure (similar to Bajaj make BGAV 302 LED) and completely wired for use on 230 250 V grade 50 cycle AC supply. Wipro Bajaj.Nos9000.09000.01.0FalseNoneNoneFalseNoneFalse9000.00
3925200151381NoneMan704Professional charges towards obtaining permission for installation as well as for running of Generator set from Chief Electrical Inspector, Chief of State Pollution Control Board and any other statutory body as may be required.LS125000.0125000.01.0FalseNoneNoneFalseNoneFalse125000.00
3925201151381NoneMan705PARTD: TELEPHONE, NETWORKING and TV SYSTEM: TELEPHONE SYSTEM Supply and fixing of RJ11 telephone socket in a suitable size modular MS Box covered with modular plate and concealed in wall including supply of all fixing materials, and associated civil works with interconnections etc. complete as required. Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable.Nos353.85353.8595.0FalseNoneNoneFalseNoneFalse33615.750
3925202151381NoneMan706TELEPHONE SYSTEM Supply and fixing of RJ11 telephone socket in a suitable size modular MS Box covered with modular plate and concealed in wall including supply of all fixing materials, and associated civil works with interconnections etc. complete as required. Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 2 pair unarmored cable.Mtr22.0522.054275.0FalseNoneNoneFalseNoneFalse94263.750
3925203151381NoneMan707TELEPHONE SYSTEM Supply and fixing of RJ11 telephone socket in a suitable size modular MS Box covered with modular plate and concealed in wall including supply of all fixing materials, and associated civil works with interconnections etc. complete as required. Supplying and drawing PVC flexible one pair telephone unarmoured tinned copper cable. 20 pair unarmored cable.Mtr157.5157.5175.0FalseNoneNoneFalseNoneFalse27562.50
3925204151381NoneMan708Supplying and fixing of MDF krone junction box with KRONE Module Telephone cable termination.: 20 pair.No402.15402.155.0FalseNoneNoneFalseNoneFalse2010.750
3925205151381NoneMan709UPS SYSTEM Supplying, erecting, testing and commissioning of ONLINE UPS system suitable for operation on 230V, 50Hz, A C supply, with isolation transformer all accessories complete and Excluding batteries and wiring complete. a) 10 kVA ON LINE UPSNos108748.5108748.52.0FalseNoneNoneFalseNoneFalse217497.00
3925206151381NoneMan710Supplying, installation, testing and commissioning of 12V DC, AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries.: 26 AH capacityNos3791.553791.55120.0FalseNoneNoneFalseNoneFalse454986.00
3925207151381NoneMan711PARTE: SUPPLY OF LIFTS: LIFTS Supply, installation, commissioning and testing of 13 passengers capacity elevators without machine room, etc., complete. Type of Elevator: Passenger Elevators Capacity of the Elevator (13 passengers) Speed: 1.50m s Number of floors to be served: Basement, ground to Fourth floor and Terrace Number of landing entrances: 7 (Seven) Number of Landing: 7 (Seven) Travel distance: 27.00m Size of Lift well available: 2700 mm x 2000mm Min. Lift pit depth available: 1600mm Lift car inside: 2300mm x 1550mm Lift car door finish: Stainless Steel Hairline finish Lift car finish for walls: Stainless Steel Hairline finish Type of car door: Automatic center opening Stainless steel hairline finish Type of landing door: Automatic center opening Stainless steel hairline finish Lift car ceiling and lighting: SS MoonlightNos2159416.352159416.351.0FalseNoneNoneFalseNoneFalse2159416.350
3925208151381NoneMan712PHE WORK: SANITARY FIXTURES and CP FITTINGS EUROPEAN WATER CLOSET : Supply, installation, testing and commissioning of approved make starWhite Coloured Wall mounting constellation model European water closet P trap outlet with 32 mm dia Concealed dual type Flush tank to enable flushing pipe work concealed behind wall supporting CI MS bracket with CP bolts and nuts, plastic seat cover of approved make and colour with rubber buffers, flap, CP hinges, CP bolts and nuts, all of approved make etc., complete. cost should include all accessories as required for installation. (Water closet Make : TOTO Hindware Parryware) (Flush tank Make : Geberit) (Hindware Cat. No for wc : 20069 (P22.5)Nos11785.211785.271.0FalseNoneNoneFalseNoneFalse836749.20
3925209151381NoneMan713HEALTH FAUCET : Supply, Installing, testing and commissioning of 15mm CP health faucet of approved make with necessary CP flexible hose 750mm long nozzle, CP angle Valve, CP wall flange complete. (Make : Jaquar Hindware Parryware)Nos1950.01950.071.0FalseNoneNoneFalseNoneFalse138450.00
3925210151381NoneMan714Providing and fixing Toilet paper holder made of Stainless steel with all concealed fitting arrangements and all necessary accesories complete Class Economy Make :Jaquar Cera ParrywareNos880.95880.9571.0FalseNoneNoneFalseNoneFalse62547.450
3925211151381NoneMan715WASH BASIN :Providing and fixing wash basin (basin above below semi counter) with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 630x450 mm with a 15 mm CP Brass single hole basin mixer, with 32mm dia CP waste coupling, 32 mm dia. CP bottle trap with PVC connecting pipe pipe, Bottle trap,M.S. wall brackets with a pair of SS screws to support the basin 1no. 15mm CP single lever Basin Mixer with , 2 no. 15mm CP angle valve with 450mm long CP inlet connection pipe, CP wall flange all of approved make, complete. (Wash Bain Make :TOTO Hindware Parryware) (CP fitting -Make :Jaquar Cera Parryware) (Hindware Cat. No for WB : 10049)Nos10368.7510368.7523.0FalseNoneNoneFalseNoneFalse238481.250
3925212151381NoneMan716WASH BASIN : Providing and fixing wash basin (basin above below semi counter) with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer, with 32mm dia CP waste coupling, 32 mm dia. CP bottle trap with PVC connecting pipe pipe, Bottle trap,M.S. wall brackets with a pair of SS screws to support the basin 1no. 15mm CP single lever Basin Mixer with , 2 no. 15mm CP angle valve with 450mm long CP inlet connection pipe, CP wall flange all of approved make, complete. (Wash Bain Make :TOTO Hindware Parryware) (CP fitting -Make :Jaquar Cera Parryware) (Hindware Cat. No for RWB: 10096)Nos9636.99636.940.0FalseNoneNoneFalseNoneFalse385476.00
3925213151381NoneMan717URINALS : Supply, installing, testing and commissioning of white glazed large small flat back Urinals SENSOR TYPE with 40mm dia CP waste coupling with dome type grating , 40mm dia CP bottle trap with extension pipe, urinal spreader, SS bolts and nuts to fix the urinal with all hangers and brackets complete with wall flanges. (Wash Bain Make :TOTO Hindware Parryware) (CP fitting -Make :Jaquar Cera Parryware) (Hindware Cat. No : 60018)Nos7108.57108.553.0FalseNoneNoneFalseNoneFalse376750.50
3925214151381NoneMan718Supply and fixing, testing and commissioning of solid state, no touch operting, fully hygienic hand drier of approved shade with blower, continuous repeat usage, time delay, summer and winter control, music while drying, volume ON OFF controls including providing necessary bracket, cable from drier to plug, plug top key and lock etc. complete as required. Make : Utec UT501Nos11300.011300.010.0FalseNoneNoneFalseNoneFalse113000.00
3925215151381NoneMan719Supply and fixing, testing and commissioning of approved make 15mm CP shower unit comprising of CP 15mm dia exposed single lever Divertor with CP spout, overhead shower set comprising of CP shower arm, rose, hand shower with flex tube etc.,complete with CP wall flanges.Nos8534.48534.48.0FalseNoneNoneFalseNoneFalse68275.20
3925216151381NoneMan720Supply and fixing, testing and commissioning of approved make 25 Liter GEYSER including necessary fittings etc,.Nos14425.014425.08.0FalseNoneNoneFalseNoneFalse115400.00
3925217151381NoneMan721Providing and fixing Double Towel rail 600mm length made of Stainless steel with all concealed fitting arrangements and all necessary accessories complete Class PREMIUMNos4057.24057.28.0FalseNoneNoneFalseNoneFalse32457.60
3925218151381NoneMan722Supply and fixing, testing and commissioning of approved make CP Double coat hook including necessary fittings.Nos294.0294.071.0FalseNoneNoneFalseNoneFalse20874.00
3925219151381NoneMan723Supply and fixing, testing and commissioning of approved make soap Tray including necessary fittings.Nos890.0890.08.0FalseNoneNoneFalseNoneFalse7120.00
3925220151381NoneMan724Supplying, fixing, testing and commissioning of approved make CP bib tap including necessary fittings.(for JANITOR ROOM)Nos1115.01115.02.0FalseNoneNoneFalseNoneFalse2230.00
3925221151381NoneMan725Providing and fixing Liquid soap dispenser made of Stainless steel with all concealed fitting arrangements and all necessary accesories complete of approved shade with continuous repeat usage, including providing necessary bracket, complete as required including cutting and making good the wall. ClassvPremium Make : Kimberly ClarkNos4005.754005.7514.0FalseNoneNoneFalseNoneFalse56080.50
3925222151381NoneMan726S.S.SINK: Collecting, Installing, testing and commissioning stainless steel sink with single bowl with drain board from 1 mm thick stainless steel, 18G high grade indestructable chrome nickel steel with top quality polish, 1 no. 50 mm dia CP waste coupling, with 1 no. 40mm dia CP bottle trap with extension pipe bottle trap with extension pipe, 15mm dia CP sink cock with swivel spout wall floor mounted type and necessary wall flanges. etc., complete. (Make Niral Franke Jaquar Cera Parryware)Nos9263.19263.17.0FalseNoneNoneFalseNoneFalse64841.70
3925223151381NoneMan727Providing and fixing in position SWR PVC Moulded (IS: 14735) Pinches, Sinches, floor trap of self cleaning design of following sizes for the embedded areas. Making proper connection with, cutting chase hole in floors slabs and bringing the same in proper condition in cement concrete 1:2:4 mix complete as required. including cost of cutting and making good the walls and floors where required. Make: Finolex Supreme: 100 mm inlet and 100 mm outlet (Urinal traps only)Nos825.0825.018.0FalseNoneNoneFalseNoneFalse14850.00
3925224151381NoneMan728Providing and fixing in position SWR PVC Moulded (IS: 14735) Pinches, Sinches, floor trap of self cleaning design of following sizes for the embedded areas. Making proper connection with, cutting chase hole in floors slabs and bringing the same in proper condition in cement concrete 1:2:4 mix complete as required. including cost of cutting and making good the walls and floors where required. Make: Finolex Supreme: 100 mm inlet and 75 mm outlet (Floor Trap only)Nos256.2256.285.0FalseNoneNoneFalseNoneFalse21777.00
3925225151381NoneMan729Supply and fixing of SS grating sutable for above mentioned floor trap (heavy quality Chilly make) and with necessary cement concrete. Make: Chilly Cat No: CCTSMHC140Nos825.0825.0103.0FalseNoneNoneFalseNoneFalse84975.00
3925226151381NoneMan730Supplying ,installation, testing and commissioning of approved make grab bar for handicap toilet including necessary fittings.Nos8566.958566.958.0FalseNoneNoneFalseNoneFalse68535.60
3925227151381NoneMan731SOIL WASTE VENT AND RAIN WATER PIPES: Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For inclusive of all necessary specials like multi floor traps (50mm water seal), bends 45 or 90 degree, Y s, tees, offsets, junctions, couplers screw type caps with rubber rings for cleanout pipe ends, etc., Running in the ceiling. All suspenders, saddles, pipe packs are to be quoted separately under relevant items. All including Toilets, Pantry s and Basement ceilings (Make :Astral , Supreme and Prince): : PVC pipes 75mm dia., 6 kg sqcm and class 3Rmtr231.0231.0750.0FalseNoneNoneFalseNoneFalse173250.00
3925228151381NoneMan732SOIL WASTE VENT AND RAIN WATER PIPES: Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For inclusive of all necessary specials like multi floor traps (50mm water seal), bends 45 or 90 degree, Y s, tees, offsets, junctions, couplers screw type caps with rubber rings for cleanout pipe ends, etc., Running in the ceiling. All suspenders, saddles, pipe packs are to be quoted separately under relevant items. All including Toilets, Pantry s and Basement ceilings (Make :Astral , Supreme and Prince): PVC pipes 110mm dia., 6 kg sqcm and class 3Rmtr431.55431.55900.0FalseNoneNoneFalseNoneFalse388395.00
3925229151381NoneMan733SOIL WASTE VENT AND RAIN WATER PIPES: Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For inclusive of all necessary specials like multi floor traps (50mm water seal), bends 45 or 90 degree, Y s, tees, offsets, junctions, couplers screw type caps with rubber rings for cleanout pipe ends, etc., Running in the ceiling. All suspenders, saddles, pipe packs are to be quoted separately under relevant items. All including Toilets, Pantry s and Basement ceilings (Make :Astral , Supreme and Prince): PVC pipes 160mm dia., 6 kg sqcm and class 3Rmtr648.9648.9100.0FalseNoneNoneFalseNoneFalse64890.00
3925230151381NoneMan734SOIL WASTE VENT AND RAIN WATER PIPES: Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead and lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For inclusive of all necessary specials like multi floor traps (50mm water seal), bends 45 or 90 degree, Y s, tees, offsets, junctions, couplers screw type caps with rubber rings for cleanout pipe ends, etc., Running in the ceiling. All suspenders, saddles, pipe packs are to be quoted separately under relevant items. All including Toilets, Pantry s and Basement ceilings (Make :Astral , Supreme and Prince): PVC pipes 200mm dia., 6 kg sqcm and class 3Rmtr1170.751170.751.0FalseNoneNoneFalseNoneFalse1170.750
3925231151381NoneMan735Supplying, fixing and testing PVC pressure pipes (6Kg sqcm) confirming to IS 4985 for waste connection from wash basin, kitchen sinks to floor trap, antisyphonage vent pipe with solvent cement joints, including all the fittings, suspended under floor slabs concealed in wall etc, the work shall include wall chase and making good the same in cement mortar. All suspenders, saddles, pipe packs are to be quoted separately under relevant items. (internal toilet) (Make :Astral , Supreme and Prince): 40mm dial (I.D.)Rmtr120.0120.0325.0FalseNoneNoneFalseNoneFalse39000.00
3925232151381NoneMan736Supplying, fixing and testing PVC pressure pipes (6Kg sqcm) confirming to IS 4985 for waste connection from wash basin, kitchen sinks to floor trap, antisyphonage vent pipe with solvent cement joints, including all the fittings, suspended under floor slabs concealed in wall etc, the work shall include wall chase and making good the same in cement mortar. All suspenders, saddles, pipe packs are to be quoted separately under relevant items. (internal toilet) (Make :Astral , Supreme and Prince): 50mm dia (I.D.)Rmtr106.05106.05180.0FalseNoneNoneFalseNoneFalse19089.00
3925233151381NoneMan737Supplying, fixing and testing PVC soil, waste, vent (SWR) confirming to IS13592 : 1990, Class A with rubber ring (confirming to IS 5382)with solvent joint inclusive of all necessary with all fittings like bends 45 or 90 degree, Y s, tees, offsets, door bends, junctions, screw type caps, vent cowl fixed in the pipe shafts on pipe racks (Vertical stacks for rain water) (Make :Astral , Supreme and Prince): 110mm dia (Type A)Rmtr480.0480.0182.0FalseNoneNoneFalseNoneFalse87360.00
3925234151381NoneMan738Supplying, fixing and testing PVC soil, waste, vent (SWR) confirming to IS13592 : 1990, Class A with rubber ring (confirming to IS 5382)with solvent joint inclusive of all necessary with all fittings like bends 45 or 90 degree, Y s, tees, offsets, door bends, junctions, screw type caps, vent cowl fixed in the pipe shafts on pipe racks (Vertical stacks for rain water) (Make :Astral , Supreme and Prince): 160mm dia (Type A)Rmtr950.0950.0315.0FalseNoneNoneFalseNoneFalse299250.00
3925235151381NoneMan739Supplying, fixing and testing PVC soil, waste, vent (SWR) confirming to IS13592 : 1990, Class A with rubber ring (confirming to IS 5382)with solvent joint inclusive of all necessary with all fittings like bends 45 or 90 degree, Y s, tees, offsets, door bends, junctions, screw type caps, vent cowl fixed in the pipe shafts on pipe racks (Vertical stacks for rain water) (Make :Astral , Supreme and Prince): 200mm dia (Type A)Rmtr1450.01450.0385.0FalseNoneNoneFalseNoneFalse558250.00
3925236151381NoneMan740Supplying, fixing and testing PVC soil, waste, vent (SWR) confirming to IS13592 : 1990, Class A with rubber ring (confirming to IS 5382)with solvent joint inclusive of all necessary with all fittings like bends 45 or 90 degree, Y s, tees, offsets, door bends, junctions, screw type caps, vent cowl fixed in the pipe shafts on pipe racks (Vertical stacks for rain water) (Make :Astral , Supreme and Prince): 250mm dia (Type A)Rmtr1655.01655.0110.0FalseNoneNoneFalseNoneFalse182050.00
3925237151381NoneMan741Supplying and fixing of PVC top grating of ACO Rainwater Roof Outlet Vertical Spigot with Dome Grate for below mentioned diameater rainwater outlets on Roof including all necessary grounting with sealants to make it absolutely water proof.: 110mm diaNos1600.01600.012.0FalseNoneNoneFalseNoneFalse19200.00
3925238151381NoneMan742Supplying and fixing of PVC top grating of ACO Rainwater Roof Outlet Vertical Spigot with Dome Grate for below mentioned diameater rainwater outlets on Roof including all necessary grounting with sealants to make it absolutely water proof.: 160mm diaNos1850.01850.012.0FalseNoneNoneFalseNoneFalse22200.00
3925239151381NoneMan743Supplying and fixing of PVC top grating of ACO Rainwater Roof Outlet Vertical Spigot with Dome Grate for below mentioned diameater rainwater outlets on Roof including all necessary grounting with sealants to make it absolutely water proof.: 200mm diaNos2150.02150.015.0FalseNoneNoneFalseNoneFalse32250.00
3925240151381NoneMan744INTERNAL WATER SUPPLY SYSTEM: Providing, fixing, jointing and testing in position the following CPVC pipes (up to 50mm SDR11 and above 50mm sch40 for sch40 pipes fittings shall be sch80) use, cut to required lengths including all necessary fittings and specials such as bends, tees, unions, reducers, flanges and plugs etc. fixing supported by M.S .angle Brackets with universal clamps,supports, etc. as per specification. And PVC pipe sleeve of larger diameter shall be provided wherever the pipes are crossing the walls chaseing floors slab and sealing the sleeves as per Consultant s requirement. Jointing, and making proper connections, cutting hole in wall floor slab and making good the same good with cement concrete 1:2:4, complete required as per specifications. ( For toilet Internal cold and Hot water Supply ) (Make :Astral, Supreme and Truflo): 20 mm diaRmtr227.85227.851320.0FalseNoneNoneFalseNoneFalse300762.00
3925241151381NoneMan745INTERNAL WATER SUPPLY SYSTEM: Providing, fixing, jointing and testing in position the following CPVC pipes (up to 50mm SDR11 and above 50mm sch40 for sch40 pipes fittings shall be sch80) use, cut to required lengths including all necessary fittings and specials such as bends, tees, unions, reducers, flanges and plugs etc. fixing supported by M.S .angle Brackets with universal clamps,supports, etc. as per specification. And PVC pipe sleeve of larger diameter shall be provided wherever the pipes are crossing the walls chaseing floors slab and sealing the sleeves as per Consultant s requirement. Jointing, and making proper connections, cutting hole in wall floor slab and making good the same good with cement concrete 1:2:4, complete required as per specifications. ( For toilet Internal cold and Hot water Supply ) (Make :Astral, Supreme and Truflo): 25 mm diaRmtr310.8310.8175.0FalseNoneNoneFalseNoneFalse54390.00
3925242151381NoneMan746INTERNAL WATER SUPPLY SYSTEM: Providing, fixing, jointing and testing in position the following CPVC pipes (up to 50mm SDR11 and above 50mm sch40 for sch40 pipes fittings shall be sch80) use, cut to required lengths including all necessary fittings and specials such as bends, tees, unions, reducers, flanges and plugs etc. fixing supported by M.S .angle Brackets with universal clamps,supports, etc. as per specification. And PVC pipe sleeve of larger diameter shall be provided wherever the pipes are crossing the walls chaseing floors slab and sealing the sleeves as per Consultant s requirement. Jointing, and making proper connections, cutting hole in wall floor slab and making good the same good with cement concrete 1:2:4, complete required as per specifications. ( For toilet Internal cold and Hot water Supply ) (Make :Astral, Supreme and Truflo): 32 mm diaRmtr390.6390.6135.0FalseNoneNoneFalseNoneFalse52731.00
3925243151381NoneMan747INTERNAL WATER SUPPLY SYSTEM: Providing, fixing, jointing and testing in position the following CPVC pipes (up to 50mm SDR11 and above 50mm sch40 for sch40 pipes fittings shall be sch80) use, cut to required lengths including all necessary fittings and specials such as bends, tees, unions, reducers, flanges and plugs etc. fixing supported by M.S .angle Brackets with universal clamps,supports, etc. as per specification. And PVC pipe sleeve of larger diameter shall be provided wherever the pipes are crossing the walls chaseing floors slab and sealing the sleeves as per Consultant s requirement. Jointing, and making proper connections, cutting hole in wall floor slab and making good the same good with cement concrete 1:2:4, complete required as per specifications. ( For toilet Internal cold and Hot water Supply ) (Make :Astral, Supreme and Truflo): 40 mm diaRmtr500.85500.85532.0FalseNoneNoneFalseNoneFalse266452.20
3925244151381NoneMan748INTERNAL WATER SUPPLY SYSTEM: Providing, fixing, jointing and testing in position the following CPVC pipes (up to 50mm SDR11 and above 50mm sch40 for sch40 pipes fittings shall be sch80) use, cut to required lengths including all necessary fittings and specials such as bends, tees, unions, reducers, flanges and plugs etc. fixing supported by M.S .angle Brackets with universal clamps,supports, etc. as per specification. And PVC pipe sleeve of larger diameter shall be provided wherever the pipes are crossing the walls chaseing floors slab and sealing the sleeves as per Consultant s requirement. Jointing, and making proper connections, cutting hole in wall floor slab and making good the same good with cement concrete 1:2:4, complete required as per specifications. ( For toilet Internal cold and Hot water Supply ) (Make :Astral, Supreme and Truflo): 50 mm diaRmtr757.05757.0518.0FalseNoneNoneFalseNoneFalse13626.90
3925245151381NoneMan749INTERNAL WATER SUPPLY SYSTEM: Providing, fixing, jointing and testing in position the following CPVC pipes (up to 50mm SDR11 and above 50mm sch40 for sch40 pipes fittings shall be sch80) use, cut to required lengths including all necessary fittings and specials such as bends, tees, unions, reducers, flanges and plugs etc. fixing supported by M.S .angle Brackets with universal clamps,supports, etc. as per specification. And PVC pipe sleeve of larger diameter shall be provided wherever the pipes are crossing the walls chaseing floors slab and sealing the sleeves as per Consultant s requirement. Jointing, and making proper connections, cutting hole in wall floor slab and making good the same good with cement concrete 1:2:4, complete required as per specifications. ( For toilet Internal cold and Hot water Supply ) (Make :Astral, Supreme and Truflo): 65 mm diaRmtr1470.01470.080.0FalseNoneNoneFalseNoneFalse117600.00
3925246151381NoneMan750INTERNAL WATER SUPPLY SYSTEM: Providing, fixing, jointing and testing in position the following CPVC pipes (up to 50mm SDR11 and above 50mm sch40 for sch40 pipes fittings shall be sch80) use, cut to required lengths including all necessary fittings and specials such as bends, tees, unions, reducers, flanges and plugs etc. fixing supported by M.S .angle Brackets with universal clamps,supports, etc. as per specification. And PVC pipe sleeve of larger diameter shall be provided wherever the pipes are crossing the walls chaseing floors slab and sealing the sleeves as per Consultant s requirement. Jointing, and making proper connections, cutting hole in wall floor slab and making good the same good with cement concrete 1:2:4, complete required as per specifications. ( For toilet Internal cold and Hot water Supply ) (Make :Astral, Supreme and Truflo): 80 mm diaRmtr1882.651882.6575.0FalseNoneNoneFalseNoneFalse141198.750
3925247151381NoneMan751Providing and fixing in position brass ball valve high or low pressure with plastic float of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipment with all leads complete as per specifications.: 20 mm diaNos329.7329.759.0FalseNoneNoneFalseNoneFalse19452.30
3925248151381NoneMan752Providing and fixing in position brass ball valve high or low pressure with plastic float of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipment with all leads complete as per specifications.: 25 mm diaNos348.6348.65.0FalseNoneNoneFalseNoneFalse1743.00
3925249151381NoneMan753Providing and fixing in position brass ball valve high or low pressure with plastic float of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipment with all leads complete as per specifications.: 32 mm diaNos795.0795.011.0FalseNoneNoneFalseNoneFalse8745.00
3925250151381NoneMan754Providing and fixing in position brass ball valve high or low pressure with plastic float of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipment with all leads complete as per specifications.: 40 mm diaNos850.0850.05.0FalseNoneNoneFalseNoneFalse4250.00
3925251151381NoneMan755Providing and fixing in position brass ball valve high or low pressure with plastic float of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipment with all leads complete as per specifications.: 50 mm diaNos985.0985.03.0FalseNoneNoneFalseNoneFalse2955.00
3925252151381NoneMan756Supplying, installing, testing and commissioning of heavy quality approved make butterfly valves with standard lever confirming to IS 13039 with necessary G.I. flanges, G.I. nuts, bolts, and washers, rubber gaskets etc., complete. : 65 mm diaRmtr1752.01752.02.0FalseNoneNoneFalseNoneFalse3504.00
3925253151381NoneMan757Supplying, installing, testing and commissioning of heavy quality approved make butterfly valves with standard lever confirming to IS 13039 with necessary G.I. flanges, G.I. nuts, bolts, and washers, rubber gaskets etc., complete. : 80 mm diaRmtr1850.01850.01.0FalseNoneNoneFalseNoneFalse1850.00
3925254151381NoneMan758Supplying, fixing and testing inlet, outlet, vent (puddle flanges for OHT) (2inches ASTM upvc sch.80 pipe + 1 Tee + 2 Elbow + 2 mosquito jali) and overflow pipes, fittings with heavy duty CI frame and man hole cover including painting with 3 coats of bitumastic paint to overhead water tank complete with SS lader PVC rungs as required by client as shown in drawing etc., complete, accessories comprising of the following for Fire and Domestic water supply. (Approx. depth = 1,5 Mts. complete for efficient maintenance of the tanks Note : All Heavy duty GI puddle flanges should be hotdip galvanised.)Set65000.065000.01.0FalseNoneNoneFalseNoneFalse65000.00
3925255151381NoneMan759Supplying, fixing, testing and commissioning of water level controler for OHT including cable etc,. Compleat.Nos18000.018000.02.0FalseNoneNoneFalseNoneFalse36000.00
3925256151381NoneMan760EXTERNAL WATER SUPPLY SYSTEM: Supplying, fixing and testing inlet, outlet, vent (puddle flange) (2inches ASTM upvc sch.80 pipe + 1 Tee + 2 Elbow + 2 mosquito jali) and overflow pipes, fittings with heavy duty circular CI frame and cover including painting with 3 coats of bitumastic paint complete with SS lader as required by client as shown in drawing etc., complete, accessories comprising of the following for Fire, Domestic and Flushing water supply.( Approx. depth = 4 5 Mts,complete all the Puddle flanges and details as given in the drawings,etc. complete for efficient maintenance of the tanks,Note : All Heavy duty GI puddle flanges should be hotdip galvanised.) (UNDERGROUND SUMP puddle flange detail)Set95000.095000.01.0FalseNoneNoneFalseNoneFalse95000.00
3925257151381NoneMan761KSRB 22 : Earthwork excavation by manual means for foundation of buildings, water supply and sanitary lines and electrical conduits etc, either in pits or in trenches 1.5m and above in width, in soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. including breaking of clods complete as per specifications.KSRB 22.1: in ordinary soil. No. KBS 2.1(a) 2.3.5Cum254.1254.125.0FalseNoneNoneFalseNoneFalse6352.50
3925258151381NoneMan762KSRB 22 : Earthwork excavation by manual means for foundation of buildings, water supply and sanitary lines and electrical conduits etc, either in pits or in trenches 1.5m and above in width, in soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. including breaking of clods complete as per specifications.KSRB 22.2 : in hard soil. No. KBS 2.1(b) 2.3.5Cum271.95271.9525.0FalseNoneNoneFalseNoneFalse6798.750
3925259151381NoneMan763Providing, fixing, jointing and testing in position the following UPVC pipes (Schd40 pipes ) cut to required lengths including all necessary fittings and specials such as bends, tees, unions, reducers, flanges and plugs etc. fixing for Terrace Ring level supported by M.S .angle Brackets with universal clamps,supports, etc. as per specification. And PVC pipe sleeve of larger diameter shall be provided wherever the pipes are crossing the walls floors slab and sealing the sleeves as per Consultant s requirement. Jointing, and making proper connections, cutting hole in wall floor slab and making good the same good with cement concrete 1:2:4, complete required as per specifications. a) 80 mm dia (Make :Astral, Supreme and Prince)Rmtr535.0535.050.0FalseNoneNoneFalseNoneFalse26750.00
3925260151381NoneMan764Providing, fixing, jointing and testing of water meter with stop cock, jam nut, sccket in GI pipe line including cutting and threading the pipe and making long screws including cost of all meteriala, labour, HOM of spesification.Nos1375.01375.01.0FalseNoneNoneFalseNoneFalse1375.00
3925261151381NoneMan765Constructing brick masonry valve chamber 450x450mm and 450 mm depth, (clear inside dimension) for single pipeline, using table moulded nonmodular bricks of class designation 50 in cement mortar 1:5, C.I cover with frame (light duty) 600x600 internal dimensions, total weight of cover with frame to be not less than 38kg (weight of cover 23kg and weight of frame 15 kg) R.C.C. Top slab with cement concrete M 15 with 20mm and downsize granite metal, foundation concrete M5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications. Specification No. KBSNos4416.04416.01.0FalseNoneNoneFalseNoneFalse4416.00
3925262151381NoneMan766EXTERNAL SEWERAGE SYSTEM: Earthwork excavation by manual means for foundation of buildings, water supply and sanitary lines and electrical conduits etc, either in pits or in trenches 1.5m and above in width, in soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. including breaking of clods complete as per specifications.: in ordinary soil. No.Cum254.1254.11.0FalseNoneNoneFalseNoneFalse254.10
3925263151381NoneMan767Earthwork excavation by manual means for foundation of buildings, water supply and sanitary lines and electrical conduits etc, either in pits or in trenches 1.5m and above in width, in soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. including breaking of clods complete as per specifications: in hard soil.Cum271.95271.951.0FalseNoneNoneFalseNoneFalse271.950
3925264151381NoneMan768Supplying, fixing and testing PVC soil, waste, vent(SWR) confirming to IS13592 : 1990, type B with solvent joint inclusive of all necessary specials like multi floor traps (50mm water seal), bends 45 or 90 degree, Y s, tees, offsets, junctions, couplers screw type caps with rubber rings for cleanout pipe ends, etc., Running in the ceiling. All suspenders, saddles, pipe packs are to be quoted separately under relevant items . (Main sewage header pipes to STP) (Make :Astral, Supreme and Truflo ): 160mm diaRmtr600.0600.01.0FalseNoneNoneFalseNoneFalse600.00
3925265151381NoneMan769Supplying, fixing and testing PVC soil, waste, vent(SWR) confirming to IS13592 : 1990, type B with solvent joint inclusive of all necessary specials like multi floor traps (50mm water seal), bends 45 or 90 degree, Y s, tees, offsets, junctions, couplers screw type caps with rubber rings for cleanout pipe ends, etc., Running in the ceiling. All suspenders, saddles, pipe packs are to be quoted separately under relevant items . (Main sewage header pipes to STP) (Make :Astral, Supreme and Truflo ): 110mm diaRmtr490.0490.01.0FalseNoneNoneFalseNoneFalse490.00
3925266151381NoneMan770Construction of 600mm X 600mm GULLY TRAP fixing with PVC inchesPinchesTrap. with 230mm best quality approved Table Moulded bricks in CM 1:4 over a bed of 100mm thick PCC 1:4:8, internal wall surfaces smooth plastered in CM 1:3 and external wall surfaces with CM 1:3 with sponge finish, benching and channelling in PCC 1:4:8. Supplying and fixing medium duty (10 MT load bearing capacity) FRP GRP square frame and cover of size suitable for a clear internal size of chamber of 600 x 600 mm The quoted rate shall also include necessary excavation and back filling. Clear internal size of the chamber 600 x 600 mm maximum depth not exceeding 900 mm.Nos8488.488488.481.0FalseNoneNoneFalseNoneFalse8488.480
3925267151381NoneMan771KSRB 128.1 : Constructing brick masonry inspection chamber 600x600mm and 1000mm depth, (clear inside dimension) for single pipeline, using table moulded nonmodular bricks of class designation 50 in cement mortar 1:5, C.I cover with frame (light duty) 600x600mm internal dimensions, total weight of cover with frame to be not less than 38kg (weight of cover 23kg and weight of frame 15 kg) R.C.C. Top slab with cement concrete M 15 with 20mm and downsize granite metal, foundation concrete M5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications.Specification No. KBSNos7075.07075.01.0FalseNoneNoneFalseNoneFalse7075.00
3925268151381NoneMan772EXTERNAL STORM WATER SYSTEM: Earthwork excavation by manual means for foundation of buildings, water supply and sanitary lines and electrical conduits etc, either in pits or in trenches 1.5m and above in width, in soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. including breaking of clods complete as per specifications: in ordinary soil. No.Cum254.1254.170.0FalseNoneNoneFalseNoneFalse17787.00
3925269151381NoneMan773Earthwork excavation by manual means for foundation of buildings, water supply and sanitary lines and electrical conduits etc, either in pits or in trenches 1.5m and above in width, in soil not exceeding 1.5 m. in depth including dressing the bottom and sides of pits and trenches, stacking the excavated soil clear from edges of excavation with lead upto 50 m. including breaking of clods complete as per specifications.Cum271.95271.9538.0FalseNoneNoneFalseNoneFalse10334.10
3925270151381NoneMan774Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead and lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for:. The quoted rate shall include necessary fittings, pipe to be laid below ground level in trenches upto required depth, dewatering, jointing of pipes, water testing and setting encasing the pipes in cement concrete M15 as per specifications 150mm thk. all around, refilling, and making good the same complete as required. (Make :Astral, Supreme and Prince ): Pipes of SN4, 110mm dia.Rmtr302.4302.42.0FalseNoneNoneFalseNoneFalse604.80
3925271151381NoneMan775Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead and lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for:. The quoted rate shall include necessary fittings, pipe to be laid below ground level in trenches upto required depth, dewatering, jointing of pipes, water testing and setting encasing the pipes in cement concrete M15 as per specifications 150mm thk. all around, refilling, and making good the same complete as required. (Make :Astral, Supreme and Prince ): Pipes of SN4, 160mm dia.Rmtr604.8604.82.0FalseNoneNoneFalseNoneFalse1209.60
3925272151381NoneMan776Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead and lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for:. The quoted rate shall include necessary fittings, pipe to be laid below ground level in trenches upto required depth, dewatering, jointing of pipes, water testing and setting encasing the pipes in cement concrete M15 as per specifications 150mm thk. all around, refilling, and making good the same complete as required. (Make :Astral, Supreme and Prince ): Pipes of SN4, 200mm dia.Rmtr872.55872.551.0FalseNoneNoneFalseNoneFalse872.550
3925273151381NoneMan777Constructing brick masonry catch basin for single pipeline, using table moulded nonmodular bricks of class designation 50 in cement mortar 1:5, C.I cover with frame (light duty) internal dimensions, total weight of cover with frame to be not less than 38kg (weight of cover 23kg and weight of frame 15 kg) R.C.C. Top slab with cement concrete M 15 with 20mm and downsize granite metal, foundation concrete M5 with 40mm and downsize granite metal inside plastering 12mm thick with cement mortar 1:3, finish smooth with a floating coat of cement on walls and bed concrete complete as per standard design including cost of materials, labour charges, curing complete as per specifications.a) 600mm x 600mm (clear internal dimension) (For catch basin)Nos7075.07075.01.0FalseNoneNoneFalseNoneFalse7075.00
3925274151381NoneMan778PUMPS AND ACCESSORIES: Providing and Supplying of Filter feed Centrifugal pumps or monoblock pump for domestic water from Treated water sump to OHT. The system shall comprises of 2 nos (1 working and 1 no. 100percent stand by pump) including with necessary unions, flanges, non return valves, other valves,. Make : DP pumps ITT GRUNDFOS 2.5 lps at 40 m Head.Nos38350.038350.04.0FalseNoneNoneFalseNoneFalse153400.00
3925275151381NoneMan779Fixing, testing and commissioning of Filter feed Centrifugal pumps or monoblock pump for domestic water from Treated water sump to OHT. The system shall comprises of 2 nos (1 working and 1 no. 100percent stand by pump) including with necessary unions, flanges, non return valves, other valves,. Make : DP pumps ITT GRUNDFOS 2.5 lps at 40 m Head.Nos2350.02350.04.0FalseNoneNoneFalseNoneFalse9400.00
3925276151381NoneMan780Providing and supplying of Filter feed Centrifugal pumps or monoblock pump for Flushing water from Flushing water sump(STP) to flushing OHT. The system shall comprises of 2 nos (1 working and 1 no. 100percent stand by pump) including with necessary unions, flanges, non return valves, other valves,. Make : DP pumps ITT GRUNDFOS 1.5 lps at 40 m Head.(1W +1S)Nos36500.036500.04.0FalseNoneNoneFalseNoneFalse146000.00
3925277151381NoneMan781Fixing, testing and commissioning of Filter feed Centrifugal pumps or monoblock pump for Flushing water from Flushing water sump(STP) to flushing OHT. The system shall comprises of 2 nos (1 working and 1 no. 100percent stand by pump) including with necessary unions, flanges, non return valves, other valves,. Make : DP pumps ITT GRUNDFOS 1.5 lps at 40 m Head.(1W +1S)Nos2350.02350.04.0FalseNoneNoneFalseNoneFalse9400.00
3925278151381NoneMan782Providing and supplying of dewatering lift pumps for PHE Fire Pump room (Submersible type) of adequate HP, capable of giving a required discharge at suitable head to work on 3Ph 50Hz, 400 440V with necessary unions, flanges, non return valves, other valves, with water level controller with cabling etc., complete. Make : DP pumps ITT GRUNDFOS 2.5 Lps at 15 m Head.(1W + 1S)Nos28320.028320.02.0FalseNoneNoneFalseNoneFalse56640.00
3925279151381NoneMan783Fixing, testing and commissioning of dewatering lift pumps for PHE Fire Pump room (Submersible type) of adequate HP, capable of giving a required discharge at suitable head to work on 3Ph 50Hz, 400 440V with necessary unions, flanges, non return valves, other valves, with water level controller with cabling etc., complete. Make : DP pumps ITT GRUNDFOS 2.5 Lps at 15 m Head.(1W + 1S)Nos2400.02400.02.0FalseNoneNoneFalseNoneFalse4800.00
3925280151381NoneMan784Providing and supplying of dewatering lift pumps for basement storm water collection sump(Submersible type) of adequate HP, capable of giving a required discharge at suitable head to work on 3Ph 50Hz, 400 440V with necessary unions, flanges, non return valves, other valves, with water level controller with cabling etc., complete. Make : DP pumps ITT GRUNDFOS 1.5 Lps at 10 m Head.(1W + 1S)Nos23320.023320.02.0FalseNoneNoneFalseNoneFalse46640.00
3925281151381NoneMan785Fixing, testing and commissioning of dewatering lift pumps for basement storm water collection sump(Submersible type) of adequate HP, capable of giving a required discharge at suitable head to work on 3Ph 50Hz, 400 440V with necessary unions, flanges, non return valves, other valves, with water level controller with cabling etc., complete. Make : DP pumps ITT GRUNDFOS 1.5 Lps at 10 m Head.(1W + 1S)Nos3180.03180.02.0FalseNoneNoneFalseNoneFalse6360.00
3925282151381NoneMan786Collecting, fixing, testing and commissioning of Filter feed Centrifugal pumps for domestic water from Raw water sump to treated water sump through the treatment Filter. The system shall comprises of 2 nos (1 working and 1 no. 100percent stand by pump) including with necessary unions, flanges, non return valves, other valves,. Make : DP pumps ITT GRUNDFOS 1.5 Lps at 30 m Head.(1W + 1S)Nos31592.031592.02.0FalseNoneNoneFalseNoneFalse63184.00
3925283151381NoneMan787Collecting, fixing, testing and commissioning of Filter feed Centrifugal pumps for domestic water from Raw water sump to treated water sump through the treatment Filter. The system shall comprises of 2 nos (1 working and 1 no. 100percent stand by pump) including with necessary unions, flanges, non return valves, other valves,. Make : DP pumps ITT GRUNDFOS 1.5 Lps at 30 m Head.(1W + 1S)Nos2350.02350.02.0FalseNoneNoneFalseNoneFalse4700.00
3925284151381NoneMan788Providing and supplying of Electrical Control panel starters for complete operation of Pumping system.LS291500.0291500.01.0FalseNoneNoneFalseNoneFalse291500.00
3925285151381NoneMan789Fixing, installaition, testing and commissioning of Electrical Control panel starters for complete operation of Pumping system.LS30000.030000.01.0FalseNoneNoneFalseNoneFalse30000.00
3925286151381NoneMan790WATER TREATMENT PLANT: Providing and Supplying of approved make pressure sand filter of MS construction with necessary equipment complete with Frontal piping, pneumatic valves, suitable supports for mounting, pressure guage, orifice plate etc..,complete as per the detailed specification for the efficient working of system. The maximum working Pressure shall be 3.5Kg Sqcm.(Note : Pump quantity included in part VII Pump and accessories) Capacity : Max flow rate = 5.0cum hrNos60060.060060.01.0FalseNoneNoneFalseNoneFalse60060.00
3925287151381NoneMan791Installing, testing and commissioning approved make pressure sand filter of MS construction with necessary equipment complete with Frontal piping, pneumatic valves, suitable supports for mounting, pressure guage, orifice plate etc..,complete as per the detailed specification for the efficient working of system. The maximum working Pressure shall be 3.5Kg Sqcm.(Note : Pump quantity included in part VII Pump and accessories) Capacity : Max flow rate = 5.0cum hrInstallationNos4500.04500.01.0FalseNoneNoneFalseNoneFalse4500.00
3925288151381NoneMan792Fixing, Supplying approved make Raw water Softener with necessary accessories complete with Frontal piping,valves,suitable supports for mounting pressure guages,orifice plates.The filter shall be made of FRP with necessary protective coating.The cost of filter shall also include initial charge of underbed and multigrade filter media to suit the requirement etc.,complete as per the standards. Max. working pressure = 3.5kg sqcm Max flow rate = 5.0cum hr,Nos112500.0112500.01.0FalseNoneNoneFalseNoneFalse112500.00
3925289151381NoneMan793Installing, testing and commissioning approved make Raw water Softener with necessary accessories complete with Frontal piping,valves,suitable supports for mounting pressure guages,orifice plates.The filter shall be made of FRP with necessary protective coating.The cost of filter shall also include initial charge of underbed and multigrade filter media to suit the requirement etc.,complete as per the standards. Max. working pressure = 3.5kg sqcm Max flow rate = 5.0cum hr, InstallationNos5260.05260.01.0FalseNoneNoneFalseNoneFalse5260.00
3925290151381NoneMan794Providing and Supplying of approved make activated carbon filter in MS vessel construction with internals, electrical control system complete with Frontal piping, valves, suitable supports for mounting, pressure gauge, orifice plate etc.., complete as per the detailed specification for the efficient working of system. The maximum working Pressure shall be 3.5 Kg Sqcm. Max flow rate = 5.0cum hr,Nos59310.059310.01.0FalseNoneNoneFalseNoneFalse59310.00
3925291151381NoneMan795Fixing and (nstalling, testing and commissioning approved make activated carbon filter in MS vessel construction with internals, electrical control system complete with Frontal piping, valves, suitable supports for mounting, pressure gauge, orifice plate etc.., complete as per the detailed specification for the efficient working of system. The maximum working Pressure shall be 3.5 Kg Sqcm. Max flow rate = 5.0cum hr,Nos4500.04500.01.0FalseNoneNoneFalseNoneFalse4500.00
3925292151381NoneMan796Providing and Supplying, installing, testing and commissioning of on line Automatic Electronic Metered Chlorine Dosing pump system including a 100L capacity storage tank etc., complete.Nos20700.020700.01.0FalseNoneNoneFalseNoneFalse20700.00
3925293151381NoneMan797Installing, testing and commissioning of on line Automatic Electronic Metered Chlorine Dosing pump system including a 100L capacity storage tank etc., complete.Nos1800.01800.01.0FalseNoneNoneFalseNoneFalse1800.00
3925294151381NoneMan798Supplying, installing, testing and commissioning inter unit piping with necessary flanges, bolts, nuts, neoprene gaskets, welding wherever necessary, with necessary control valves, non return valves etc and with one coat of primer and two coats of approved enamel paint etc., complete.Lot35200.035200.01.0FalseNoneNoneFalseNoneFalse35200.00
3925295151381NoneMan799Fiixing, testing and commissioning inter unit piping with necessary flanges, bolts, nuts, neoprene gaskets, welding wherever necessary, with necessary control valves, non return valves etc and with one coat of primer and two coats of approved enamel paint etc., complete.Lot4800.04800.01.0FalseNoneNoneFalseNoneFalse4800.00
3925296151381NoneMan800Supplying and providing of Level Switch for pump controlNos6200.06200.01.0FalseNoneNoneFalseNoneFalse6200.00
3925297151381NoneMan801Fixing and installation of Level Switch for pump controlNos650.0650.01.0FalseNoneNoneFalseNoneFalse650.00
3925298151381NoneMan802Supply, and Providing of water Flow meter to measure 0 5 cum hr, etc., completeNos14500.014500.01.0FalseNoneNoneFalseNoneFalse14500.00
3925299151381NoneMan803Fixing and installatopm of water Flow meter to measure 0 5 cum hr, etc., completeNos1500.01500.01.0FalseNoneNoneFalseNoneFalse1500.00
3925300151381NoneMan804Providing and supplying of Electrical Control panel starters for complete operation of WTP SystemLS69120.069120.01.0FalseNoneNoneFalseNoneFalse69120.00
3925301151381NoneMan805Fixing and Installation of Electrical Control panel starters for complete operation of WTP SystemLS7680.07680.01.0FalseNoneNoneFalseNoneFalse7680.00
3925302151381NoneMan80625 KLD SEWAGE TREATMENT PLANT(SBR) (stp capacity higher side considering future expansion) Raw Sewage transfer pumps, Vertical centrifugal submersiable pumpsets with CI body and SS Shaft and with mechanical seal type 1 working + 1 standby with Capacity Head of 2.5 cum h at 10 mtr head. (Make: Grundfos Kirlosakar) (Purpose:For uniform pumping of raw sewage to SBR reactor from Equalisation tank)Nos39650.039650.02.0FalseNoneNoneFalseNoneFalse79300.00
3925303151381NoneMan807Air blower (Driven by electric motor) Twin lobe air blowers type 1 working + 1 standby with Capacity Head of 70 cum hr. Max. operating pressure 0.50 kg sqcm. (Blower Make : Everest KPT KAY) (Motor Make : Kirlosakar) MOC :CI (Purpose:To provide aeration and carry out oxidation process and reduce BOD COD in SBR reactor, to provide mixing in equalization tank and sludge tank.)Nos113000.0113000.02.0FalseNoneNoneFalseNoneFalse226000.00
3925304151381NoneMan808Fine Bubble diffusers Imported fine bubble with silicon EPDM membrane in SBR tank, size 63 mm OD X 1000 mm long with SS clamps type (Make:Southern cogen ) (Purpose:Uniform air distribution into SBR tank )Nos3800.03800.08.0FalseNoneNoneFalseNoneFalse30400.00
3925305151381NoneMan809Coarse Bubble diffusers Imported Coarse bubble with silicon EPDM membrane in Equalisation tank and Sludge holding tank Size 63 mm OD X 1000 mm long with SS clamps type (Make:Southern cogen ) (Purpose:Uniform air distribution into equivalisation tank and sludge tank)Nos3400.03400.04.0FalseNoneNoneFalseNoneFalse13600.00
3925306151381NoneMan810Acoustic Enclosure :Supply, installation, testing and commissioning of acoustic enclosure for Air Blower fabricated out MS with 100mm thick Rockwool insulation so as to cut down the noise. The enclosure shall be provided with ventilating fan. The size of the enclosure shall be such that the enclosure can house two air blowers in one enclosure. Rate quoted shall be for 2 enclosuresNos150000.0150000.02.0FalseNoneNoneFalseNoneFalse300000.00
3925307151381NoneMan811Filter feed pumps Horizontal centrifugal non clog type pump set with CI impeller and mechnical Seal type, (1 working + 1 standby) with a Capacity Head of 2 cum hr at 35 mtr. Head ( Make : Kirlosakar) (Purpose : For pumping the clarified water for filteration through PSF and ACF with adequate pressure)Nos25000.025000.02.0FalseNoneNoneFalseNoneFalse50000.00
3925308151381NoneMan812Bar screen : Type of screen M.S. Epoxy painted construction manually cleaned with flats placed at 10mm C C with M.S. hard rake with handle all epoxy painted.(Make : GEPS) (Purpose :Screening of Non degradable floating solids from incoming sewage and protection of pumps, and other equipment s etc. )Nos11000.011000.01.0FalseNoneNoneFalseNoneFalse11000.00
3925309151381NoneMan813Pressure Sand filter : Flow 2 cum hr with working pressure of 3.5 kg sqcm, Dimensions 800 mm Dia X 1500 Height. MOC MS with Epoxy Coated and Silica Sand Media. (Make : GEPS) (Filtration and removal of trae suspended solids, carried over biomass etc. and improviding quality of treated water.)Nos90000.090000.01.0FalseNoneNoneFalseNoneFalse90000.00
3925310151381NoneMan814Activated Carbon Filter : Flow 2 cum hr with working pressure of 3.5 kg sqcm, Dimensions 800 mm Dia X 1500 Height. MOC MS with Epoxy Coated and Activated carbon IV900 grade (Make : GEPS) ( Purpose :Filtration and removal of trae suspended solids, trace organic matter, removal of color and odour, and improving quality of treated water.)Nos92000.092000.01.0FalseNoneNoneFalseNoneFalse92000.00
3925311151381NoneMan815Decantar System : Flow 2.5 cum hr with Flooting Tubler Type, Material PP, Dimensions 150mm. (Make : MAX)Nos48000.048000.01.0FalseNoneNoneFalseNoneFalse48000.00
3925312151381NoneMan816Screw pump : Capacity of 1 cum hr at 50 mtr. Head (Make : ALFA) ( Purpose :To pump sludge for sludge dewatering unit for suldge treatment.)Nos18000.018000.01.0FalseNoneNoneFalseNoneFalse18000.00
3925313151381NoneMan817Filter press : Size 470 mm x 470 mm 9 plates approx. Manual type, (Make : Royal precission ) ( Purpose : To dewater the sludge and to form dry sludge which can be easily disposeed off or can be used as manure.)Nos110000.0110000.01.0FalseNoneNoneFalseNoneFalse110000.00
3925314151381NoneMan818Hypo Chloride dosing system: Capacity 02 LPH (Make : Edose ) ( Purpose : For disinfection of treated water.)Nos9000.09000.01.0FalseNoneNoneFalseNoneFalse9000.00
3925315151381NoneMan819Supplying, installation, testing and commissioning of Ultra filtration system with suitable UF Membrane, UF Feed Pump (1W+1S), UF Backwash Pump (1W+1S), PLC based auto panel, UF Skid made of SS 304, Basket Stainer, necessary dosing system as per membrane manufacturer specificationSet500000.0500000.01.0FalseNoneNoneFalseNoneFalse500000.00
3925316151381NoneMan820a) Air blower line except submerged air piping, type GI C Class, (Make : Jindal TATA )Nos34000.034000.01.0FalseNoneNoneFalseNoneFalse34000.00
3925317151381NoneMan821b) All other pipe line for pumps UPVC type, (Makes of Astral Finolex Prince equivalent)Nos30000.030000.01.0FalseNoneNoneFalseNoneFalse30000.00
3925318151381NoneMan822c) Float level switch (Make : Laptron Minilec. equivalent )Nos8000.08000.01.0FalseNoneNoneFalseNoneFalse8000.00
3925319151381NoneMan823d) Sub merged air grid pipe and fittings CPVC type, (Makes Astral Prince Finolex equivalent )Nos14000.014000.01.0FalseNoneNoneFalseNoneFalse14000.00
3925320151381NoneMan824e) Pressure guage ( Make : H Guru Warre equivalent )Nos12000.012000.01.0FalseNoneNoneFalseNoneFalse12000.00
3925321151381NoneMan825f) Rotameter (Make : Aster Kranthi Pratham equivalent)Nos18000.018000.01.0FalseNoneNoneFalseNoneFalse18000.00
3925322151381NoneMan826g) Valves ( Make : Mark sant equivalent )Nos18000.018000.01.0FalseNoneNoneFalseNoneFalse18000.00
3925323151381NoneMan827h) Pipe supports : Galvanised M.S. section of required sizeNos17000.017000.01.0FalseNoneNoneFalseNoneFalse17000.00
3925324151381NoneMan828i) Anchor fastneners : Standard make of approved qualityNos10000.010000.01.0FalseNoneNoneFalseNoneFalse10000.00
3925325151381NoneMan829j) Welding rods: Standard make of approved qualityNos4000.04000.01.0FalseNoneNoneFalseNoneFalse4000.00
3925326151381NoneMan830Consumanbles : a) Nuts, Bolts, washers type M.S. hard dip GI Nut boltsNos16000.016000.01.0FalseNoneNoneFalseNoneFalse16000.00
3925327151381NoneMan831Consumanbles : b) Electrical Cables (Make:Poly cab Finolex Gloster)Nos20000.020000.01.0FalseNoneNoneFalseNoneFalse20000.00
3925328151381NoneMan832Consumanbles : c) Cable tray Z angle type M.S. hard dip GINos16000.016000.01.0FalseNoneNoneFalseNoneFalse16000.00
3925329151381NoneMan833Providing, supplying, commissioning and fixing of Electrical control panel :as per the detailed drawing and specification and the direction of engineer in charge of work.Job177000.0177000.01.0FalseNoneNoneFalseNoneFalse177000.00
3925330151381NoneMan834Erection and commissioning of the Sewage Treatment Plant including Transportation Charges as per the drawing, specification and instruction of engineer in charge of workJob180000.0180000.01.0FalseNoneNoneFalseNoneFalse180000.00
3925331151381NoneMan835FIRE FIGHTING WORKS: FIRE PUMP ROOM EQUIPMENT: Supply, installation, testing and Commissioning of approved make centrifugal pump end suction type couple to electrical motor of suitable HP, fitted on a common base frame and rated for for fire duty.The quoted price shall also include 2 nos. Pressure gauge fitted on suction and delivery side of the pump. The pump shall run on 400 440V,3ph.35Hz Electrical supply. Duty of pump 2280 Lpm at 70M Head.No230375.0230375.01.0FalseNoneNoneFalseNoneFalse230375.00
3925332151381NoneMan836Supply, installation, testing and Commissioning of Diesel Engine driven fire pump suitable for automatic operation comprising of the following and conforming to BS 649 IS 10002 all amended upto date. Supply, installation, testing and Commissioning of fire hydrant multi stage pump capable of delivering 2280 lpm at 70.0 m head coupled to water cooled diesel engine of adequiate HP. It shall be fitted with a radiator on a common base from with complete ancilalary units such as colling system,non return valve,y stainer,fuel tank of adequate capacity,pressure gauge,pressure switch.No395850.0395850.01.0FalseNoneNoneFalseNoneFalse395850.00
3925333151381NoneMan837Supplying, Installing, testing and commisioning electrically driven jockey pump of capacity 180.0 Lpm at 70.0m head with all the necessary accessories viz. Pressure guages etc. operating on 3Ph 50Hz, 400 440 V AC supply incldung foudnation, bolts etc. complete Control panel shall be per specification stated in Item No.87. including cost of materials, labour, HOM complete as per specifications. (Cost of controle pannel is not included)No61736.061736.01.0FalseNoneNoneFalseNoneFalse61736.00
3925334151381NoneMan838Common Pump Control panel (Complete suit as per above mentioned pump spesifications): Fabricating and Supply, installing, testing and commissioning of compartmentalised common control panel for Electrical motor driven pumps and Jockey driven pumps. INCOMING 1 no. 250A TPN MCCB (25 KA). 1 Set of 250 Amps. TPN Al. Bus bars with colour coded heat shrinkable PVC sleeves. 1 Set of RYB indicating lamps with individual HRC control fuses. 1 No. 144 Sq.mm 0250 Amps. Ammeter with selector selector switch and suitable rated current transformers. 1 No. 0500 144 Sq.mm Voltmeter with selector switch. OUTGOING Feeder for 55 HP main pumps 1 Nos. 1 No.160 A TPN SFU with back up fuses Star Delta starter with over load relay, single phase preventor and indicating lamps with ON OFF push buttons. Feeder for 6 HP Jockey pump 1 No. 1 No. 32A TPN SFU with back up fuses star delta starter with over load relay, single phase preventor and indicating lamps with ON OFF push buttons. 1 No. Automanual selector switchNo295000.0295000.01.0FalseNoneNoneFalseNoneFalse295000.00
3925335151381NoneMan8391100 V GRADE POWER CONTROL CABLES : Supplying, laying, testing and commissioning of PVC XLPE insulated PVC sheathed, steel armoured, aluminium copper conductor, 100v grade power cables.The cables shall be laid in tray Hume pipe in trenches on walls floor etc. as required. : 3.5C x 50 sq.mm Aluminium. XLPERmtr600.0600.050.0FalseNoneNoneFalseNoneFalse30000.00
3925336151381NoneMan8401100 V GRADE POWER CONTROL CABLES : Supplying, laying, testing and commissioning of PVC XLPE insulated PVC sheathed, steel armoured, aluminium copper conductor, 100v grade power cables.The cables shall be laid in tray Hume pipe in trenches on walls floor etc. as required. : 4C x 25 sq.mm Aluminium. XLPERmtr300.0300.040.0FalseNoneNoneFalseNoneFalse12000.00
3925337151381NoneMan8411100 V GRADE POWER CONTROL CABLES : Supplying, laying, testing and commissioning of PVC XLPE insulated PVC sheathed, steel armoured, aluminium copper conductor, 100v grade power cables.The cables shall be laid in tray Hume pipe in trenches on walls floor etc. as required. : 2C x 2.5 Sqmm. Aluminium PVCRmtr210.0210.050.0FalseNoneNoneFalseNoneFalse10500.00
3925338151381NoneMan842CABLE TRAY (PERFORATED TYPE) Supplying and installing following size of perforated cable trays made out of 2mm thick Pregalvanised sheet steel and 16SWG unperforated type covers perforation not more than 17.5percent, in convenient sections, joined with connectors, suspended from the ceiling with Galvanised M10 Hitech rod suspenders including bolts, Anchor fasteners and nuts, etc with all accessories like bends, reducers, Tee s, cross members, etc. complete as required. 300 mm width X 50 mm depth X 1.6 mm thicknessRmtr616.35616.3525.0FalseNoneNoneFalseNoneFalse15408.750
3925339151381NoneMan843G.I. Earthing strips of, strip shall be run on floor ceiling walls, from the equipment to the nearest Earth pit with neccessory accessories as required. (Earth pit shall be executed by other agencies).: 25mm x 6mm thickRmtr134.0134.025.0FalseNoneNoneFalseNoneFalse3350.00
3925340151381NoneMan844Supplying, installing, testing and commissioning of M.S. Pipes confirming to IS 3589,6.35 mm thick for Dia 150 mm and above and below 150 mm the pipe shall cfn IS 1239 part1 (heavy duty), with specials such as Tees, elbows, flanges. Including cutting, Welding, fixing in on walls, ceiling by using suitable supports etc, as per drawings.: 200mm nominal diaRmtr2100.02100.010.0FalseNoneNoneFalseNoneFalse21000.00
3925341151381NoneMan845Supplying, installing, testing and commissioning of M.S. Pipes confirming to IS 3589,6.35 mm thick for Dia 150 mm and above and below 150 mm the pipe shall cfn IS 1239 part1 (heavy duty), with specials such as Tees, elbows, flanges. Including cutting, Welding, fixing in on walls, ceiling by using suitable supports etc, as per drawings.: 150 mm Nominal diaRmtr2000.02000.020.0FalseNoneNoneFalseNoneFalse40000.00
3925342151381NoneMan846Supplying, installing, testing and commissioning of M.S. Pipes confirming to IS 3589,6.35 mm thick for Dia 150 mm and above and below 150 mm the pipe shall cfn IS 1239 part1 (heavy duty), with specials such as Tees, elbows, flanges. Including cutting, Welding, fixing in on walls, ceiling by using suitable supports etc, as per drawings.: 100mm nominal diaRmtr1188.01188.05.0FalseNoneNoneFalseNoneFalse5940.00
3925343151381NoneMan847Supplying, installing, testing and commissioning of M.S. Pipes confirming to IS 3589,6.35 mm thick for Dia 150 mm and above and below 150 mm the pipe shall cfn IS 1239 part1 (heavy duty), with specials such as Tees, elbows, flanges. Including cutting, Welding, fixing in on walls, ceiling by using suitable supports etc, as per drawings.: 80 mm nominal diaRmtr1024.01024.05.0FalseNoneNoneFalseNoneFalse5120.00
3925344151381NoneMan848Supplying, Installing, testing and commissioning CI butterfly valves(PN 1.6) slim seal standared lever operated type confirming to BS:5155 with required flanges, nuts, bolts etc. complete.: 200mm nominal diaNos12680.012680.01.0FalseNoneNoneFalseNoneFalse12680.00
3925345151381NoneMan849Supplying, Installing, testing and commissioning CI butterfly valves(PN 1.6) slim seal standared lever operated type confirming to BS:5155 with required flanges, nuts, bolts etc. complete.: 150mm nominal diaNos9500.09500.04.0FalseNoneNoneFalseNoneFalse38000.00
3925346151381NoneMan850Supplying, Installing, testing and commissioning CI butterfly valves(PN 1.6) slim seal standared lever operated type confirming to BS:5155 with required flanges, nuts, bolts etc. complete.: 100mm nominal diaNos7000.07000.02.0FalseNoneNoneFalseNoneFalse14000.00
3925347151381NoneMan851Supplying, installing, testing and commissioning approved make Cast Iron body brass pot and Y strainer with necessary flanges, nuts and bolts etc., complete on to the suction line.: 200mm nominal dia Pot strainerNos30200.030200.01.0FalseNoneNoneFalseNoneFalse30200.00
3925348151381NoneMan852Supplying, installing, testing and commissioning of C.I. Nonreturn valves as per IS:5312( PN 10) swing check type with required flanges, nuts, bolts and gaskets etc. complete.: 200 mm nominal diaNos12600.012600.01.0FalseNoneNoneFalseNoneFalse12600.00
3925349151381NoneMan853Supplying, installing, testing and commissioning of C.I. Nonreturn valves as per IS:5312( PN 10) swing check type with required flanges, nuts, bolts and gaskets etc. complete.: 150 mm Nominal diaNos9005.09005.02.0FalseNoneNoneFalseNoneFalse18010.00
3925350151381NoneMan854Supplying, installing, testing and commissioning of C.I. Nonreturn valves as per IS:5312( PN 10) swing check type with required flanges, nuts, bolts and gaskets etc. complete.: 100 mm nominal diaNos6900.06900.01.0FalseNoneNoneFalseNoneFalse6900.00
3925351151381NoneMan855EXTERNAL HYDRANT SYSTEM: Supply, Installation testing and commissioning of approved make heavy tubes (Class ‘C’) confirming to as per IS1239 Part I (25mm Nominal bore 4.05mm thick at 2.97 Kg m, 32mm Nominal bore 4.05mm thick at 3.84 Kg m,40mm Nominal bore 4.05mm thick at 4.43 Kg m,50mm Nominal bore 4.47mm thick at 6.17 Kg m, 65mm Nominal bore 4.47mm thick at 7.90 Kg m, 80mm Nominal bore 4.85mm thick at 10.10 Kg m, 100mm Nominal bore5.40mm thick at 14.40 Kg m,150mm Nominal bore 5.40mm thick at 21.20 Kg m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41Tech pipe M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications.: 150mm nominal diaRmtr1755.01755.016.0FalseNoneNoneFalseNoneFalse28080.00
3925352151381NoneMan856Supply, Installation testing and commissioning of approved make heavy tubes (Class ‘C’) confirming to as per IS1239 Part I (25mm Nominal bore 4.05mm thick at 2.97 Kg m, 32mm Nominal bore 4.05mm thick at 3.84 Kg m,40mm Nominal bore 4.05mm thick at 4.43 Kg m,50mm Nominal bore 4.47mm thick at 6.17 Kg m, 65mm Nominal bore 4.47mm thick at 7.90 Kg m, 80mm Nominal bore 4.85mm thick at 10.10 Kg m, 100mm Nominal bore5.40mm thick at 14.40 Kg m,150mm Nominal bore 5.40mm thick at 21.20 Kg m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41Tech pipe M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications.: 80mm nominal diaRmtr1056.01056.015.0FalseNoneNoneFalseNoneFalse15840.00
3925353151381NoneMan857Supplying and wrapping the anticorrosive material for buried pipes with coating of Primer and wrapping with 4 mm thick polymer corrosion resistnt tape as per IS : 10221 with 15 mm overlap as per specifications. : 150mm nominal diaRmtr105.0105.016.0FalseNoneNoneFalseNoneFalse1680.00
3925354151381NoneMan858Supplying and wrapping the anticorrosive material for buried pipes with coating of Primer and wrapping with 4 mm thick polymer corrosion resistnt tape as per IS : 10221 with 15 mm overlap as per specifications.: 80mm nominal diaRmtr80.080.015.0FalseNoneNoneFalseNoneFalse1200.00
3925355151381NoneMan859Supplying, installing and commissioning of fire brigade inlet inlet connection of 2 way with 2 nos. 63 mm dia. built in Gun metal Non return valves instantaneous coupling type arranged on 150 mm dia. Pipe manifold and connected to wet riser main. Qouted rate shall be included with C.I. Butterfly valve, C.I. check valve and M.S. cabinet of suitable size with mounting supports etc. complete.Nos9850.09850.01.0FalseNoneNoneFalseNoneFalse9850.00
3925356151381NoneMan860Supplying, installing and commissioning of fire brigade inlet inlet connection of 4 way with 4 nos. 63 mm dia. built in Gun metal Non return valves instantaneous coupling type arranged on 150 mm dia. Pipe manifold and connected to wet riser main. Qouted rate shall be included with C.I. Butterfly valve, C.I. check valve and M.S. cabinet of suitable size with mounting supports etc. complete.Nos12500.012500.01.0FalseNoneNoneFalseNoneFalse12500.00
3925357151381NoneMan861Supplying, installing, testing and commissioning of yard hydrant comprising of a) Supplying Installing, testing and commissioning of 63mm mm dia single headed Gun mental Hydrant Valve with flanged inlet, stop valve, spindle and cast iron hand wheel. It has a female instantaneous outlet with Blank Cap and is Hydrostatically tested to 21 Kgf cm2 pressure having a flow rate of 900 LPM at 7 Kgf cm 2 of pressure with blank cap and wheel as per IS 5290 etc. complete. Make : WINCO NEW Age including cost of materials, labour, HOM, Complete as per specifications. (Make : WINCO NEW Age)Nos5244.05244.05.0FalseNoneNoneFalseNoneFalse26220.00
3925358151381NoneMan862Supplying, installing, testing and commissioning of yard hydrant comprising of b) Supplying Installing, testing and commissioning of Reinforced Rubber Lined RRL Fire hose of 63mm dia 15m length as per IS 8423 binded with one set of male and Female Instantainious Gun metal coupling as per IS 903 WINCO NEW AGE complete including cost of materials, labour, HOM complete as per specifications Make : WINCO NEW AgeNos5242.05242.010.0FalseNoneNoneFalseNoneFalse52420.00
3925359151381NoneMan863Supplying, installing, testing and commissioning of yard hydrant comprising of c) Supplying Installing, testing and commissioning of Gun metal Branch pipe size of 63mm dia x19mm dia as per IS 903 Make: WINCO NEW AGE complete including cost of materials, labour, HOM complete as per specifications. Make : WINCO NEW AgeNos2232.02232.05.0FalseNoneNoneFalseNoneFalse11160.00
3925360151381NoneMan864Supplying Installing, testing and commissioning of Hose cabinet made out of 18 gauge M.S.sheet with double glass door with locing arrangement and painted with two coats of Fire red Enamel paint at outer ise of the Box and two coats of white enamel paint at inner side of the box is to accomodated 2 Nos. of Fire hose box size 20”x24”x10” complete including cost of materials, labour, HOM complete as per specifications.Nos3199.03199.05.0FalseNoneNoneFalseNoneFalse15995.00
3925361151381NoneMan865CIVIL WORKS: Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings and bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting and stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools and other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum254.1254.195.0FalseNoneNoneFalseNoneFalse24139.50
3925362151381NoneMan866Providing and laying Reinforced Cement Concrete pipe light duty NP2 for culverts, roadway utilitiesand crossingsas per IS 458:2003 in Single row including pointing ends and fixing collars with cement mortar 1:2 including cost of all materials, labour, curing completeas per specifications 300mm DiaRmtr895.65895.6520.0FalseNoneNoneFalseNoneFalse17913.00
3925363151381NoneMan867INTERNAL HYDRANT SYSTEM: Supplying, erecting and commissioning of internal Hydrants comprising of the following in the Fire duct: a) Supplying Installing, testing and commissioning of 63mm mm dia single headed Gun mental Hydrant Valve with flanged inlet, stop valve, spindle and cast iron hand wheel. It has a female instantaneous outlet with Blank Cap and is Hydrostatically tested to 21 Kgf cm2 pressure having a flow rate of 900 LPM at 7 Kgf cm 2 of pressure with blank cap and wheel as per IS 5290 etc. complete. Make : WINCO NEW Age including cost of materials, labour, HOM complete as per specifications. (Make : WINCO NEW Age)Nos5244.05244.010.0FalseNoneNoneFalseNoneFalse52440.00
3925364151381NoneMan868Supplying, erecting and commissioning of internal Hydrants comprising of the following in the Fire duct: b) Supplying Installing, testing and commissioning of Reinforced Rubber Lined RRL Fire hose of 63mm dia 15m length as per IS 8423 binded with one set of male and Female Instantainious Gun metal coupling as per IS 903 WINCO NEW AGE complete including cost of materials, labour, HOM complete as per specifications Make : WINCO NEW AgeNos5242.05242.020.0FalseNoneNoneFalseNoneFalse104840.00
3925365151381NoneMan869Supplying, erecting and commissioning of internal Hydrants comprising of the following in the Fire duct: c) Supplying Installing, testing and commissioning of Gun metal Branch pipe size of 63mm dia x19mm dia as per IS 903 Make: WINCO NEW AGE complete including cost of materials, labour, HOM complete as per specifications. Make : WINCO NEW AgeNo2232.02232.010.0FalseNoneNoneFalseNoneFalse22320.00
3925366151381NoneMan870Supplying, erecting and commissioning of internal Hydrants comprising of the following in the Fire duct: d) Supplying Installing, testing and commissioning of Hose reel cabin M.S.Pressed reel of 600mm dia swinging type motion which allows a 180 degree swing and conforms to IS:884 85. including cost of materials, labour, HOM complete as per specifications.Nos3869.03869.010.0FalseNoneNoneFalseNoneFalse38690.00
3925367151381NoneMan871Supplying, erecting and commissioning of internal Hydrants comprising of the following in the Fire duct: e) Supplying Installing, testing and commissioning of 19mm dia 36.50m length hose with rubber lining smooth bore, reinforced of natural synthetic fibres, a rubber cover finish shall be smooth, fluted or fabric marked with minimum thickness of 1.50mm and to with stand a working pressure of 10Kgf sqcm confirms and tested as per IS 444 including cost of materials, labour, HOM complete as per specifications.Nos3869.03869.016.0FalseNoneNoneFalseNoneFalse61904.00
3925368151381NoneMan872Supplying, erecting and commissioning of internal Hydrants comprising of the following in the Fire duct: f) Supplying, installing, testing and commissioning of Fire duct Shutter fabricated out of M.S. sheet of 16 swg., door shall be 900mm x 1200 mm min. and fixed with 4 mm thick Glass, suitable Rubber beeding and Locking arrangement. Quoted rate shall be includes all fasteners etc, and complete shutter shall be powder coated of approved colour both inside and out side.Nos6200.06200.010.0FalseNoneNoneFalseNoneFalse62000.00
3925369151381NoneMan873Supplying and fixing approved make 25mm dia. With automatic air release valve with unions, ball valve etc. complete.: 25mm dia.Nos1562.01562.02.0FalseNoneNoneFalseNoneFalse3124.00
3925370151381NoneMan874Supplying, Installing, testing and commissioning CI butterfly valves(PN 16) slim seal standared lever operated type confirming to BS:5155 with required flanges, nuts, bolts etc. complete.: 100mm nominal diaNos7000.07000.02.0FalseNoneNoneFalseNoneFalse14000.00
3925371151381NoneMan875Supplying, installing, testing and commissioning approved make Cast Iron body brass pot and Y strainer with necessary flanges, nuts and bolts etc., complete on to the suction line.: 100mm nominal dia Y strainerNos26000.026000.01.0FalseNoneNoneFalseNoneFalse26000.00
3925372151381NoneMan876Supplying, installing, testing and commissioning of C.I. Nonreturn valves as per IS:5312(PN 16) swing check type with required flanges, nuts, bolts and gaskets etc. complete.: 100 mm nominal diaNos9005.09005.01.0FalseNoneNoneFalseNoneFalse9005.00
3925373151381NoneMan877Supplying, installing, testing and commissioning of GI Pipes conforming to IS 1239Part1 Heavy grade with 2 cote primer and painting, suitable type of supports(Shall be fabricated by MS Channel Angle Flat for above 50 mm dia), anchor fasteners, bolts nuts, inchesUinches clamps, bolt, M.S.angles malleable specials such as Reducers, Tees, elbows, flanges. Including cutting, Welding, fixing in on walls, ceiling by using suitable supports etc, as per drawings. The quoted rate shall also include for chasing chipping walls, making bore holes in walls floor and making them good with filler material and finished in cement mortar including two coats of metal primer and two coates of red enamel paint etc. complete.: a) 150mm nominal diaRmtr1755.01755.0195.0FalseNoneNoneFalseNoneFalse342225.00
3925374151381NoneMan878Supplying, installing, testing and commissioning of GI Pipes conforming to IS 1239Part1 Heavy grade with 2 cote primer and painting, suitable type of supports(Shall be fabricated by MS Channel Angle Flat for above 50 mm dia), anchor fasteners, bolts nuts, inchesUinches clamps, bolt, M.S.angles malleable specials such as Reducers, Tees, elbows, flanges. Including cutting, Welding, fixing in on walls, ceiling by using suitable supports etc, as per drawings. The quoted rate shall also include for chasing chipping walls, making bore holes in walls floor and making them good with filler material and finished in cement mortar including two coats of metal primer and two coates of red enamel paint etc. complete.: b) 100mm nominal diaRmtr1575.01575.011.0FalseNoneNoneFalseNoneFalse17325.00
3925375151381NoneMan879Supplying, installing, testing and commissioning of GI Pipes conforming to IS 1239Part1 Heavy grade with 2 cote primer and painting, suitable type of supports(Shall be fabricated by MS Channel Angle Flat for above 50 mm dia), anchor fasteners, bolts nuts, inchesUinches clamps, bolt, M.S.angles malleable specials such as Reducers, Tees, elbows, flanges. Including cutting, Welding, fixing in on walls, ceiling by using suitable supports etc, as per drawings. The quoted rate shall also include for chasing chipping walls, making bore holes in walls floor and making them good with filler material and finished in cement mortar including two coats of metal primer and two coates of red enamel paint etc. complete.: c) 80mm nominal diaRmtr1056.01056.070.0FalseNoneNoneFalseNoneFalse73920.00
3925376151381NoneMan880SPRINKLER SYSTEM: Supplying Installing, testing and commissioning of approved make 15mm dia sprinkler bulb pendent wall mounted type designed to operate 68 degrees centegrad Make Tyco HD FIRE complete (Colour code of bulb liquid inside Glass bulb type Pendents As per IS 9972: 57 degree C Orange, 68 degree C Red, 79 degree C Yellow, 93 degree C Green, 141 degree C Blue, 182 degree C Mauve, 227 260 degree C Black) including cost of materials, labour, HOM complete as per specifications.: a) (Pendant Type)Nos530.0530.0556.0FalseNoneNoneFalseNoneFalse294680.00
3925377151381NoneMan881Supplying Installing, testing and commissioning of approved make 15mm dia sprinkler bulb pendent wall mounted type designed to operate 68 degrees centegrad Make Tyco HD FIRE complete (Colour code of bulb liquid inside Glass bulb type Pendents As per IS 9972: 57 degree C Orange, 68 degree C Red, 79 degree C Yellow, 93 degree C Green, 141 degree C Blue, 182 degree C Mauve, 227 260 degree C Black) including cost of materials, labour, HOM complete as per specifications.: b) (Upright Type)Nos530.0530.0650.0FalseNoneNoneFalseNoneFalse344500.00
3925378151381NoneMan882Supplying Installing, testing and commissioning of approved make 15mm dia sprinkler bulb pendent wall mounted type designed to operate 68 degrees centegrad Make Tyco HD FIRE complete (Colour code of bulb liquid inside Glass bulb type Pendents As per IS 9972: 57 degree C Orange, 68 degree C Red, 79 degree C Yellow, 93 degree C Green, 141 degree C Blue, 182 degree C Mauve, 227 260 degree C Black) including cost of materials, labour, HOM complete as per specifications.: c) (Side through)Nos530.0530.052.0FalseNoneNoneFalseNoneFalse27560.00
3925379151381NoneMan883Supply, Installation testing and commissioning of approved make heavy tubes (Class ‘C’) confirming to as per IS1239 Part I (25mm Nominal bore 4.05mm thick at 2.97 Kg m, 32mm Nominal bore 4.05mm thick at 3.84 Kg m, 40mm Nominal bore 4.05mm thick at 4.43 Kg m,50mm Nominal bore 4.47mm thick at 6.17 Kg m, 65mm Nominal bore 4.47mm thick at 7.90 Kg m, 80mm Nominal bore 4.85mm thick at 10.10 Kg m, 100mm Nominal bore5.40mm thick at 14.40 Kg m,150mm Nominal bore 5.40mm thick at 21.20 Kg m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41Tech pipe M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications.: a) 150mm nominal diaRmtr1755.01755.075.0FalseNoneNoneFalseNoneFalse131625.00
3925380151381NoneMan884Supply, Installation testing and commissioning of approved make heavy tubes (Class ‘C’) confirming to as per IS1239 Part I (25mm Nominal bore 4.05mm thick at 2.97 Kg m, 32mm Nominal bore 4.05mm thick at 3.84 Kg m, 40mm Nominal bore 4.05mm thick at 4.43 Kg m,50mm Nominal bore 4.47mm thick at 6.17 Kg m, 65mm Nominal bore 4.47mm thick at 7.90 Kg m, 80mm Nominal bore 4.85mm thick at 10.10 Kg m, 100mm Nominal bore5.40mm thick at 14.40 Kg m,150mm Nominal bore 5.40mm thick at 21.20 Kg m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41Tech pipe M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications.: b) 100mm nominal diaRmtr1575.01575.080.0FalseNoneNoneFalseNoneFalse126000.00
3925381151381NoneMan885Supply, Installation testing and commissioning of approved make heavy tubes (Class ‘C’) confirming to as per IS1239 Part I (25mm Nominal bore 4.05mm thick at 2.97 Kg m, 32mm Nominal bore 4.05mm thick at 3.84 Kg m, 40mm Nominal bore 4.05mm thick at 4.43 Kg m,50mm Nominal bore 4.47mm thick at 6.17 Kg m, 65mm Nominal bore 4.47mm thick at 7.90 Kg m, 80mm Nominal bore 4.85mm thick at 10.10 Kg m, 100mm Nominal bore5.40mm thick at 14.40 Kg m,150mm Nominal bore 5.40mm thick at 21.20 Kg m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41Tech pipe M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications.: c) 80mm nominal diaRmtr1056.01056.0150.0FalseNoneNoneFalseNoneFalse158400.00
3925382151381NoneMan886Supply, Installation testing and commissioning of approved make heavy tubes (Class ‘C’) confirming to as per IS1239 Part I (25mm Nominal bore 4.05mm thick at 2.97 Kg m, 32mm Nominal bore 4.05mm thick at 3.84 Kg m, 40mm Nominal bore 4.05mm thick at 4.43 Kg m,50mm Nominal bore 4.47mm thick at 6.17 Kg m, 65mm Nominal bore 4.47mm thick at 7.90 Kg m, 80mm Nominal bore 4.85mm thick at 10.10 Kg m, 100mm Nominal bore5.40mm thick at 14.40 Kg m,150mm Nominal bore 5.40mm thick at 21.20 Kg m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41Tech pipe M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications.: d) 65mm nominal diaRmtr942.0942.0175.0FalseNoneNoneFalseNoneFalse164850.00
3925383151381NoneMan887Supply, Installation testing and commissioning of approved make heavy tubes (Class ‘C’) confirming to as per IS1239 Part I (25mm Nominal bore 4.05mm thick at 2.97 Kg m, 32mm Nominal bore 4.05mm thick at 3.84 Kg m, 40mm Nominal bore 4.05mm thick at 4.43 Kg m,50mm Nominal bore 4.47mm thick at 6.17 Kg m, 65mm Nominal bore 4.47mm thick at 7.90 Kg m, 80mm Nominal bore 4.85mm thick at 10.10 Kg m, 100mm Nominal bore5.40mm thick at 14.40 Kg m,150mm Nominal bore 5.40mm thick at 21.20 Kg m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41Tech pipe M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications.: e) 50mm nominal diaRmtr827.0827.0360.0FalseNoneNoneFalseNoneFalse297720.00
3925384151381NoneMan888Supply, Installation testing and commissioning of approved make heavy tubes (Class ‘C’) confirming to as per IS1239 Part I (25mm Nominal bore 4.05mm thick at 2.97 Kg m, 32mm Nominal bore 4.05mm thick at 3.84 Kg m, 40mm Nominal bore 4.05mm thick at 4.43 Kg m,50mm Nominal bore 4.47mm thick at 6.17 Kg m, 65mm Nominal bore 4.47mm thick at 7.90 Kg m, 80mm Nominal bore 4.85mm thick at 10.10 Kg m, 100mm Nominal bore5.40mm thick at 14.40 Kg m,150mm Nominal bore 5.40mm thick at 21.20 Kg m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41Tech pipe M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications.: f) 40mm nominal diaRmtr731.0731.0365.0FalseNoneNoneFalseNoneFalse266815.00
3925385151381NoneMan889Supply, Installation testing and commissioning of approved make heavy tubes (Class ‘C’) confirming to as per IS1239 Part I (25mm Nominal bore 4.05mm thick at 2.97 Kg m, 32mm Nominal bore 4.05mm thick at 3.84 Kg m, 40mm Nominal bore 4.05mm thick at 4.43 Kg m,50mm Nominal bore 4.47mm thick at 6.17 Kg m, 65mm Nominal bore 4.47mm thick at 7.90 Kg m, 80mm Nominal bore 4.85mm thick at 10.10 Kg m, 100mm Nominal bore5.40mm thick at 14.40 Kg m,150mm Nominal bore 5.40mm thick at 21.20 Kg m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41Tech pipe M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications.: g) 32mm nominal diaRmtr683.0683.085.0FalseNoneNoneFalseNoneFalse58055.00
3925386151381NoneMan890Supply, Installation testing and commissioning of approved make heavy tubes (Class ‘C’) confirming to as per IS1239 Part I (25mm Nominal bore 4.05mm thick at 2.97 Kg m, 32mm Nominal bore 4.05mm thick at 3.84 Kg m, 40mm Nominal bore 4.05mm thick at 4.43 Kg m,50mm Nominal bore 4.47mm thick at 6.17 Kg m, 65mm Nominal bore 4.47mm thick at 7.90 Kg m, 80mm Nominal bore 4.85mm thick at 10.10 Kg m, 100mm Nominal bore5.40mm thick at 14.40 Kg m,150mm Nominal bore 5.40mm thick at 21.20 Kg m, Such as Tees elbows check nuts unions, Flanger, Nipples etc. including cutting welding, Trending fixing on walls, ceiling (Using 41Tech pipe M.S.angle supports work includes two coats of metal primer and two coats of Red enamel paint etc. including cost of materials, labour, HOM complete as per specifications.: h) 25mm nominal diaRmtr635.0635.0800.0FalseNoneNoneFalseNoneFalse508000.00
3925387151381NoneMan891Supplying, installing, testing and commissioning of hydraulically operated 150mm Sprinkler control valve, with water motor gong bell and trims as required, pressure gauges, drain valves, ball valves, check valves, strainers etc. complete.Nos19800.019800.01.0FalseNoneNoneFalseNoneFalse19800.00
3925388151381NoneMan892Sprinkler Annunciation panel of 20 window capacity, for indicating the status of Flow switch mounted on the Sprinkler distribution main. Panel shall be solid state type with LED indicating lamps, push buttons like accept, reset, ON OFF etc. as reuqired with battery back up.Nos52000.052000.01.0FalseNoneNoneFalseNoneFalse52000.00
3925389151381NoneMan893Supplying, installing, testing and commissioning flow switch on sprinkler distribution header on each floor and shall be connected to Annunciation panel through cable. Cable shall be measured seperately.: a) 150mm nominal diaNos5000.05000.08.0FalseNoneNoneFalseNoneFalse40000.00
3925390151381NoneMan894Supplying, installing, testing and commissioning flow switch on sprinkler distribution header on each floor and shall be connected to Annunciation panel through cable. Cable shall be measured seperately.: b) 100mm nominal diaNos4100.04100.02.0FalseNoneNoneFalseNoneFalse8200.00
3925391151381NoneMan895Supplying, installation, testing and commissioning of 2 runs of 1.5 sq.mm cross section armored cable.Rmtr110.0110.0350.0FalseNoneNoneFalseNoneFalse38500.00
3925392151381NoneMan896Supplying Installing, testing and commissioning of Gun metal AIR RELEASE VALVE SIZE OF 25mm dia including cost of materials, labour, HOM complete as per specifications. CompleteNos1562.01562.03.0FalseNoneNoneFalseNoneFalse4686.00
3925393151381NoneMan897Supplying, Installing, testing and commissioning CI butterfly valves (PN 1.6) slim seal standared lever operated type confirming to BS:5155 with required flanges, nuts, bolts etc. complete: . a) 150 mm nominal diaNos9500.09500.06.0FalseNoneNoneFalseNoneFalse57000.00
3925394151381NoneMan898Supplying, Installing, testing and commissioning CI butterfly valves (PN 1.6) slim seal standared lever operated type confirming to BS:5155 with required flanges, nuts, bolts etc. complete: .b) 100 mm nominal diaNos7000.07000.02.0FalseNoneNoneFalseNoneFalse14000.00
3925395151381NoneMan899SIGNAGES: Providing and fixing Fire Exit Sign Board (Size:15inchesx6inches)Nos1150.01150.012.0FalseNoneNoneFalseNoneFalse13800.00
3925396151381NoneMan900Providing and fixing of Floor Name Board (Size:15inchesx6inches)Nos1150.01150.012.0FalseNoneNoneFalseNoneFalse13800.00
3925397151381NoneMan901Providing and fixing of Use Staircase incase Fire (Size:18inchesx8inches)Nos1450.01450.012.0FalseNoneNoneFalseNoneFalse17400.00
3925398151381NoneMan902FIRE EXTINGUISHERS: Supplying, installing and commissioning Portable Fire extinguishers of following type and capacity. Providing CO2 Aluminium 4.5kg Providing 4.5Kg CO2 Gas Type aluminium body Squeeze grip Fire Extinugisher, Trolley Mounted, Easy Weight Management, Used Unused Mechanism, Squeeze Grip, Gross Weight 11.16Kg. empty Weight 6.66Kg. Can Height 860MM Diameter 140MM, Discharge Time less than10 Secs, Controllable discharge mechanism, Applicable on Class BandC Fire, B Rating 13B, Can Constuction : Cold Impact Extrusion, Valve Construction : Forging and Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Aluminium metal ISO and PESO Approved, 3 Year Warranty. including cost of materials, labour, HOM complete as per specifications. completeNos11785.011785.010.0FalseNoneNoneFalseNoneFalse117850.00
3925399151381NoneMan903Providing CO2 Aluminium 2.0kg Providing 2Kg CO2 Gas aluminium body Squeeze grip Fire Extinugisher, Used Unused Mechanism, Squeeze Grip, Gross Weight 5.16 Kg. empty Weight 3.16Kg. Can Height 615MM Diameter 111MM, Discharge Time less than 8 Secs, Controllable discharge mechanism, Applicable on Class BandC Fire, B Rating 13B, Can Constuction : Cold Impact Extrusion, Valve Construction : Forging and Machining, Internal Coating of Can : Not Applicable, External coating of Can : Spray Painting, Aluminium metal ISO and PESO Approved, 3 Year Warranty. including cost of materials, labour, HOM complete as per specifications. completeNos8102.08102.08.0FalseNoneNoneFalseNoneFalse64816.00
3925400151381NoneMan904Providing green Mist 9ltr Providing 9 Ltr Fire Extinugisher Aqueous FilmForming Foam Type, Stored Pressure Type, Pressure Gauge, Gross Weight 15.10kg. empty weight 6.10kg Can Height 615MM, Diameter 175 MM, Discharge Time less than 60 Secs, Controllable discharge mechanism (Squeeze grip with easy snap safety seal), Range minimum 6 Meters, applicable on Class A,B,C A Rating 13A, B Rating 55B, Can Construction Deep drawn and CO, Mig welded, Valve Construction: Forging and Machining, Internal Coating of Can : Epoxy Powder coating, External Coating of Can : Epoxy Polyster Powder coating, Sheet metal thickness: 2.0MM, ISI and EN Approved, Helium Leak Detection Tested, 1 Years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, HOM complete as per specifications. completeNos6055.06055.08.0FalseNoneNoneFalseNoneFalse48440.00
3925401151381NoneMan905Providing ABC Powder based MAP 50, 6.0KG Providing 6kg Fire Extinguisher Mono Ammonium Phosphate Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight 9.5 Kg, empty weight 3.5 Kg, Can Height 435MM, Diameter 160MM, Discharge Time less than 9 Secs, Controllable discharge mechanism(Squeeze grip with easy snap safety seal), Range minimum 4 meters, applicable on Class A,B,C and electrically started Fire, A Rating 3A, B Rating 21B, Can construction : Deep drawn and Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster power coating, Sheet metal thickness: 1.60MM, Helium Leak Detection Tested, ISI and EN Approved, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, HOM complete as per specifications. completeNos4849.04849.08.0FalseNoneNoneFalseNoneFalse38792.00
3925402151381NoneMan906Providing ABC Powder based MAP 50, 2.0KG Providing 2kg Fire Extinguisher Mono Ammonium Phosphate Powder 50, Stored Pressure Type, Pressure Gauge, Gross Weight 3.6 Kg, empty weight 1.6 Kg, Can Height 344MM, Diameter 108MM, Discharge Time less than 8 Secs, Controllable discharge mechanism(Squeeze grip with easy snap safety seal), Range minimum 2 meters, applicable on Class A,B,C and electrically started Fire, A Rating 1A, B Rating 8B, Can construction : Deep drawn and Co., Mig welded, valve Construciton : Forging and Mechining, Internal Coating of Can: Epoxy powder coating, External Coating of Can: Epoxy Polyster power coatng, Sheet metal thickness: 1.60MM, 5 years Warranty with instalert system with Superior quality EPDM Rubber Hosepipe etc., including cost of materials, labour, HOM complete as per specifications. complete.No2872.02872.026.0FalseNoneNoneFalseNoneFalse74672.00
3925403151381NoneMan907Supply of 2 bucket stand along with 2 buckets.Nos469.0469.08.0FalseNoneNoneFalseNoneFalse3752.00
3925404151381NoneMan908HVAC WORKS: AIRCONDITIONING SYSTEMS: VRV VRF units Air Conditioning Units : Supply, Installation, Testing and Commissioning of Variable Refrigerant Flow modular type airconditioning system complete with indoor and outdoor units with individual controller as per the following capacities of the IDU and ODU. VRF AIR CONDITIONING UNITS Efficiency as per ASHRAE 90.1 (HiCOP units) COP to be specified along with quote. VRV OUTDOOR UNITS: Micro proceessor controlled VRV Outdoor unit with hermetically sealed Scroll Rotary inverter type compressor and pre charged with HFC refrigerant ( capable of modulating capacity from 20percent 100percent. The unit shall be completely factory wired and tested with necessary controls. Unit shall be equipped with oil recovery system to ensure stable operation with long refrigerant piping. The unit shall be factory charged and any topup gas oil required for first charge should be included in the individual price quoted below. This shall include the nitrogen leak testing, oil charging, vaccumisation. The unit shall be compatible for (Modbus Bacnet Lonwork) BMS operation. VRF with each module of outdoor unit should have multiple compressors and minimum 50percent of them should be inverter type compressor all inverter type compressors. Vendor to submit detailed derating calculations of the VRV unit, Equipment performance data, Refrigerant piping and control schemes along with the offer. The ODU shall have condenser fan capable of minmum 7 speeds for saving energy at various loading conditions. The outdoor unit shall be weather proof casing constructed from heavy gauge mild steel panels and coated with anticorrosive enamel finish. Aluminum fins for condenser coils shall be provided with anticorrosive Hydrophilic coating equivalent. ODU shall be mounted on the suitable Vibration isolators. The outdoor and indoor units shall be integrated with special super wiring system with a central monitoring remote controller into one common wiring. No false ceiling is provided hence workmanship shall be of highest quality : 6 HPNo135000.0135000.01.0FalseNoneNoneFalseNoneFalse135000.00
3925405151381NoneMan909VRV VRF units Air Conditioning Units : Supply, Installation, Testing and Commissioning of Variable Refrigerant Flow modular type airconditioning system complete with indoor and outdoor units with individual controller as per the following capacities of the IDU and ODU. VRF AIR CONDITIONING UNITS Efficiency as per ASHRAE 90.1 (HiCOP units) COP to be specified along with quote. VRV OUTDOOR UNITS: Micro proceessor controlled VRV Outdoor unit with hermetically sealed Scroll Rotary inverter type compressor and pre charged with HFC refrigerant ( capable of modulating capacity from 20percent 100percent. The unit shall be completely factory wired and tested with necessary controls. Unit shall be equipped with oil recovery system to ensure stable operation with long refrigerant piping. The unit shall be factory charged and any topup gas oil required for first charge should be included in the individual price quoted below. This shall include the nitrogen leak testing, oil charging, vaccumisation. The unit shall be compatible for (Modbus Bacnet Lonwork) BMS operation. VRF with each module of outdoor unit should have multiple compressors and minimum 50percent of them should be inverter type compressor all inverter type compressors. Vendor to submit detailed derating calculations of the VRV unit, Equipment performance data, Refrigerant piping and control schemes along with the offer. The ODU shall have condenser fan capable of minmum 7 speeds for saving energy at various loading conditions. The outdoor unit shall be weather proof casing constructed from heavy gauge mild steel panels and coated with anticorrosive enamel finish. Aluminum fins for condenser coils shall be provided with anticorrosive Hydrophilic coating equivalent. ODU shall be mounted on the suitable Vibration isolators. The outdoor and indoor units shall be integrated with special super wiring system with a central monitoring remote controller into one common wiring. No false ceiling is provided hence workmanship shall be of highest quality : 8 HPNo168000.0168000.01.0FalseNoneNoneFalseNoneFalse168000.00
3925406151381NoneMan910VRV VRF units Air Conditioning Units : Supply, Installation, Testing and Commissioning of Variable Refrigerant Flow modular type airconditioning system complete with indoor and outdoor units with individual controller as per the following capacities of the IDU and ODU. VRF AIR CONDITIONING UNITS Efficiency as per ASHRAE 90.1 (HiCOP units) COP to be specified along with quote. VRV OUTDOOR UNITS: Micro proceessor controlled VRV Outdoor unit with hermetically sealed Scroll Rotary inverter type compressor and pre charged with HFC refrigerant ( capable of modulating capacity from 20percent 100percent. The unit shall be completely factory wired and tested with necessary controls. Unit shall be equipped with oil recovery system to ensure stable operation with long refrigerant piping. The unit shall be factory charged and any topup gas oil required for first charge should be included in the individual price quoted below. This shall include the nitrogen leak testing, oil charging, vaccumisation. The unit shall be compatible for (Modbus Bacnet Lonwork) BMS operation. VRF with each module of outdoor unit should have multiple compressors and minimum 50percent of them should be inverter type compressor all inverter type compressors. Vendor to submit detailed derating calculations of the VRV unit, Equipment performance data, Refrigerant piping and control schemes along with the offer. The ODU shall have condenser fan capable of minmum 7 speeds for saving energy at various loading conditions. The outdoor unit shall be weather proof casing constructed from heavy gauge mild steel panels and coated with anticorrosive enamel finish. Aluminum fins for condenser coils shall be provided with anticorrosive Hydrophilic coating equivalent. ODU shall be mounted on the suitable Vibration isolators. The outdoor and indoor units shall be integrated with special super wiring system with a central monitoring remote controller into one common wiring. No false ceiling is provided hence workmanship shall be of highest quality : 10HPNo195500.0195500.01.0FalseNoneNoneFalseNoneFalse195500.00
3925407151381NoneMan911VRV VRF units Air Conditioning Units : Supply, Installation, Testing and Commissioning of Variable Refrigerant Flow modular type airconditioning system complete with indoor and outdoor units with individual controller as per the following capacities of the IDU and ODU. VRF AIR CONDITIONING UNITS Efficiency as per ASHRAE 90.1 (HiCOP units) COP to be specified along with quote. VRV OUTDOOR UNITS: Micro proceessor controlled VRV Outdoor unit with hermetically sealed Scroll Rotary inverter type compressor and pre charged with HFC refrigerant ( capable of modulating capacity from 20percent 100percent. The unit shall be completely factory wired and tested with necessary controls. Unit shall be equipped with oil recovery system to ensure stable operation with long refrigerant piping. The unit shall be factory charged and any topup gas oil required for first charge should be included in the individual price quoted below. This shall include the nitrogen leak testing, oil charging, vaccumisation. The unit shall be compatible for (Modbus Bacnet Lonwork) BMS operation. VRF with each module of outdoor unit should have multiple compressors and minimum 50percent of them should be inverter type compressor all inverter type compressors. Vendor to submit detailed derating calculations of the VRV unit, Equipment performance data, Refrigerant piping and control schemes along with the offer. The ODU shall have condenser fan capable of minmum 7 speeds for saving energy at various loading conditions. The outdoor unit shall be weather proof casing constructed from heavy gauge mild steel panels and coated with anticorrosive enamel finish. Aluminum fins for condenser coils shall be provided with anticorrosive Hydrophilic coating equivalent. ODU shall be mounted on the suitable Vibration isolators. The outdoor and indoor units shall be integrated with special super wiring system with a central monitoring remote controller into one common wiring. No false ceiling is provided hence workmanship shall be of highest quality : 12HPNo231500.0231500.01.0FalseNoneNoneFalseNoneFalse231500.00
3925408151381NoneMan912VRV VRF units Air Conditioning Units : Supply, Installation, Testing and Commissioning of Variable Refrigerant Flow modular type airconditioning system complete with indoor and outdoor units with individual controller as per the following capacities of the IDU and ODU. VRF AIR CONDITIONING UNITS Efficiency as per ASHRAE 90.1 (HiCOP units) COP to be specified along with quote. VRV OUTDOOR UNITS: Micro proceessor controlled VRV Outdoor unit with hermetically sealed Scroll Rotary inverter type compressor and pre charged with HFC refrigerant ( capable of modulating capacity from 20percent 100percent. The unit shall be completely factory wired and tested with necessary controls. Unit shall be equipped with oil recovery system to ensure stable operation with long refrigerant piping. The unit shall be factory charged and any topup gas oil required for first charge should be included in the individual price quoted below. This shall include the nitrogen leak testing, oil charging, vaccumisation. The unit shall be compatible for (Modbus Bacnet Lonwork) BMS operation. VRF with each module of outdoor unit should have multiple compressors and minimum 50percent of them should be inverter type compressor all inverter type compressors. Vendor to submit detailed derating calculations of the VRV unit, Equipment performance data, Refrigerant piping and control schemes along with the offer. The ODU shall have condenser fan capable of minmum 7 speeds for saving energy at various loading conditions. The outdoor unit shall be weather proof casing constructed from heavy gauge mild steel panels and coated with anticorrosive enamel finish. Aluminum fins for condenser coils shall be provided with anticorrosive Hydrophilic coating equivalent. ODU shall be mounted on the suitable Vibration isolators. The outdoor and indoor units shall be integrated with special super wiring system with a central monitoring remote controller into one common wiring. No false ceiling is provided hence workmanship shall be of highest quality : 24HP (Combination of 12HP+12HP)No536000.0536000.01.0FalseNoneNoneFalseNoneFalse536000.00
3925409151381NoneMan913VRV VRF Ceiling Mounted Ductable Units : Supply, Installation, Testing and Commissioning of Ceiling mounted indoor units, Galvanized steel casing ( High external static) with cooling coil, electronic expansion valve and multispeed fan motor. The fan shall be aerodynamically designed turbo multiblade type. The blower shall be Statically and dynamically balanced for silent operation. The filters shall be Plasma and synthetic washable media type arranged for convenient cleaning and replacement, built in drain pump. The drain pan shall be fabricated out of heavy sheet steel insulated, 6mm expanded polythylene sheet with Anit Bacterial treatment. (Low Operating noise level to be considered for the units) suitable Vibration Isolators flexible canvas connection between indoor unit and duct. (a) Nominal capacity: 10.0TR, Dehumidified Air Qty : 4000CFM.Nos145050.0145050.01.0FalseNoneNoneFalseNoneFalse145050.00
3925410151381NoneMan914Cordless Wireless Remote Controllers which shall be sleek and self diagnostic type with necessary Controller.Nos3850.03850.01.0FalseNoneNoneFalseNoneFalse3850.00
3925411151381NoneMan915VRV VRF Ceiling Mounted 4 Way Cassette Unit Round Flow Type Units : Supply, Installation, Testing and Commissioning of Ceiling mounted 4way Type Round Flow Type cassette indoor units with cooling coil, electronic expansion valve and multispeed fan motor, with individual louver Airflow direction setting arrangement. The fan shall be aerodynamically designed turbo multiblade type. The blower shall be Statically and dynamically balanced for silent operation. The filters shall be Plasma and synthetic washable media type arranged for convenient cleaning and replacement, built in drain pump suitable to lift water not less than 600mm. The drain pan shall be fabricated out of heavy sheet steel insulated with 6mm expanded polythylene sheet. (Mounting of Units is on exposd concrete ceiling No false ceiling) : Nominal capacity: 1.1TR, Dehumidified Air Qty : 400CFMNos39500.039500.02.0FalseNoneNoneFalseNoneFalse79000.00
3925412151381NoneMan916VRV VRF Ceiling Mounted 4 Way Cassette Unit Round Flow Type Units : Supply, Installation, Testing and Commissioning of Ceiling mounted 4way Type Round Flow Type cassette indoor units with cooling coil, electronic expansion valve and multispeed fan motor, with individual louver Airflow direction setting arrangement. The fan shall be aerodynamically designed turbo multiblade type. The blower shall be Statically and dynamically balanced for silent operation. The filters shall be Plasma and synthetic washable media type arranged for convenient cleaning and replacement, built in drain pump suitable to lift water not less than 600mm. The drain pan shall be fabricated out of heavy sheet steel insulated with 6mm expanded polythylene sheet. (Mounting of Units is on exposd concrete ceiling No false ceiling) : Nominal capacity: 1.6TR, Dehumidified Air Qty : 600CFMNos40500.040500.02.0FalseNoneNoneFalseNoneFalse81000.00
3925413151381NoneMan917VRV VRF Ceiling Mounted 4 Way Cassette Unit Round Flow Type Units : Supply, Installation, Testing and Commissioning of Ceiling mounted 4way Type Round Flow Type cassette indoor units with cooling coil, electronic expansion valve and multispeed fan motor, with individual louver Airflow direction setting arrangement. The fan shall be aerodynamically designed turbo multiblade type. The blower shall be Statically and dynamically balanced for silent operation. The filters shall be Plasma and synthetic washable media type arranged for convenient cleaning and replacement, built in drain pump suitable to lift water not less than 600mm. The drain pan shall be fabricated out of heavy sheet steel insulated with 6mm expanded polythylene sheet. (Mounting of Units is on exposd concrete ceiling No false ceiling) : Nominal capacity: 2.0TR, Dehumidified Air Qty : 800CFMNos42850.042850.04.0FalseNoneNoneFalseNoneFalse171400.00
3925414151381NoneMan918Cordless Wireless Remote Controllers which shall be sleek and self diagnostic type FOR Cassette unit type.Nos4150.04150.08.0FalseNoneNoneFalseNoneFalse33200.00
3925415151381NoneMan919Cassette unit Decoration Panel Colour of the panel shall be as approved by Architect Client.Nos5700.05700.08.0FalseNoneNoneFalseNoneFalse45600.00
3925416151381NoneMan920VRV VRF Wall Mounted Hi WallUnit : Supply, installation, testing and commissioning of following minimum capacity VRV VRF High wall type Indoor unit equipped with washable synthetic media prefilter, fan section with low noisefan dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitablefor operation on 230 V 10percent, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System : Nominal capacity: 1.0TR, Dehumidified Air Qty : 400CFMNos36500.036500.02.0FalseNoneNoneFalseNoneFalse73000.00
3925417151381NoneMan921VRV VRF Wall Mounted Hi WallUnit : Supply, installation, testing and commissioning of following minimum capacity VRV VRF High wall type Indoor unit equipped with washable synthetic media prefilter, fan section with low noisefan dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitablefor operation on 230 V 10percent, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System : Nominal capacity: 1.6TR, Dehumidified Air Qty : 600CFMNos38450.038450.04.0FalseNoneNoneFalseNoneFalse153800.00
3925418151381NoneMan922VRV VRF Wall Mounted Hi WallUnit : Supply, installation, testing and commissioning of following minimum capacity VRV VRF High wall type Indoor unit equipped with washable synthetic media prefilter, fan section with low noisefan dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cord less remote control, drain pan, necessary accessories etc., suitablefor operation on 230 V 10percent, 50 Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System : Nominal capacity: 2.0TR, Dehumidified Air Qty : 800CFMNos41250.041250.02.0FalseNoneNoneFalseNoneFalse82500.00
3925419151381NoneMan923Supply and Installation of Floor mounted Double skin Air handling Unit with thermal break profile, 45 mm thick PUF Panel, DIDW backward curved fans, MERV8 Prefilter, Limit switches, Removable Access door, Return air and fresh air damper and 6 row interwind DX Cooling Coil of following capacity AHU Capacity : 20 TR , 8000 Cfm with 50 mm total static connected with 2 nos of 24HP VRF ODU Mixing Box Required. (Thermal break profile: Required, SA RA FA dampers shall be of GI aerofoil design, Motor Efficiency and FEG inline with ASHRAE 90.12013.Nos365000.0365000.01.0FalseNoneNoneFalseNoneFalse365000.00
3925420151381NoneMan924Bypass Starter panel for Above AHUNos24800.024800.01.0FalseNoneNoneFalseNoneFalse24800.00
3925421151381NoneMan925VFD for Above AHUNos38500.038500.01.0FalseNoneNoneFalseNoneFalse38500.00
3925422151381NoneMan926Supply of AHU kits to connect VRF ODU with third party AHU (Dx Controller + Expansion Valve Kit) Number of unit should be suitable to unit capacity.Nos48000.048000.01.0FalseNoneNoneFalseNoneFalse48000.00
3925423151381NoneMan927Supply of central remote controllerNos128000.0128000.01.0FalseNoneNoneFalseNoneFalse128000.00
3925424151381NoneMan928Supply and Installation of Power protection panel for the VRF outdoor units with suitable inter connecting cable from vrf indoor unit to vrf outdoor unit complete and as required.Lot31500.031500.02.0FalseNoneNoneFalseNoneFalse63000.00
3925425151381NoneMan929Lifting and Shifting of AHU and VRF Outdoor and Indoor units.Lot150000.0150000.01.0FalseNoneNoneFalseNoneFalse150000.00
3925426151381NoneMan930Supply and installation of suitable refnut joints to connect the VRF indoor units with outdoor unit.Lot21500.021500.02.0FalseNoneNoneFalseNoneFalse43000.00
3925427151381NoneMan93124HP Communication KitLot15800.015800.01.0FalseNoneNoneFalseNoneFalse15800.00
3925428151381NoneMan932REFRIGERANT PIPING: PIPES RUNNING THROUGH EXPOSED AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves and thickness of insulation as per Determine proper thickness recommendations (minimum Rvalue) for the thermal insulation as per latest edition of ASHRAE 90.1 or ECBC, whichever is stringent. This shall ensure minimum energy savings of 2040 BTU loss per hour per square foot. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement and proper self locking nylon zip ties black color in certain intervals. (Class 0 insulation to be used for outdoors will require protection from UV exposure). Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 41.28mm (OD)Rmtr1580.01580.040.0FalseNoneNoneFalseNoneFalse63200.00
3925429151381NoneMan933PIPES RUNNING THROUGH EXPOSED AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves and thickness of insulation as per Determine proper thickness recommendations (minimum Rvalue) for the thermal insulation as per latest edition of ASHRAE 90.1 or ECBC, whichever is stringent. This shall ensure minimum energy savings of 2040 BTU loss per hour per square foot. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement and proper self locking nylon zip ties black color in certain intervals. (Class 0 insulation to be used for outdoors will require protection from UV exposure). Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings: 38.1mm (OD)Rmtr1480.01480.04.0FalseNoneNoneFalseNoneFalse5920.00
3925430151381NoneMan934PIPES RUNNING THROUGH EXPOSED AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves and thickness of insulation as per Determine proper thickness recommendations (minimum Rvalue) for the thermal insulation as per latest edition of ASHRAE 90.1 or ECBC, whichever is stringent. This shall ensure minimum energy savings of 2040 BTU loss per hour per square foot. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement and proper self locking nylon zip ties black color in certain intervals. (Class 0 insulation to be used for outdoors will require protection from UV exposure). Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 34.93mm (OD)Rmtr1480.01480.04.0FalseNoneNoneFalseNoneFalse5920.00
3925431151381NoneMan935PIPES RUNNING THROUGH EXPOSED AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves and thickness of insulation as per Determine proper thickness recommendations (minimum Rvalue) for the thermal insulation as per latest edition of ASHRAE 90.1 or ECBC, whichever is stringent. This shall ensure minimum energy savings of 2040 BTU loss per hour per square foot. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement and proper self locking nylon zip ties black color in certain intervals. (Class 0 insulation to be used for outdoors will require protection from UV exposure). Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 31.8mm (OD)Rmtr1310.01310.04.0FalseNoneNoneFalseNoneFalse5240.00
3925432151381NoneMan936PIPES RUNNING THROUGH EXPOSED AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves and thickness of insulation as per Determine proper thickness recommendations (minimum Rvalue) for the thermal insulation as per latest edition of ASHRAE 90.1 or ECBC, whichever is stringent. This shall ensure minimum energy savings of 2040 BTU loss per hour per square foot. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement and proper self locking nylon zip ties black color in certain intervals. (Class 0 insulation to be used for outdoors will require protection from UV exposure). Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 28.58mm (OD)Rmtr1310.01310.060.0FalseNoneNoneFalseNoneFalse78600.00
3925433151381NoneMan937PIPES RUNNING THROUGH EXPOSED AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves and thickness of insulation as per Determine proper thickness recommendations (minimum Rvalue) for the thermal insulation as per latest edition of ASHRAE 90.1 or ECBC, whichever is stringent. This shall ensure minimum energy savings of 2040 BTU loss per hour per square foot. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement and proper self locking nylon zip ties black color in certain intervals. (Class 0 insulation to be used for outdoors will require protection from UV exposure). Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 25.4mm (OD)Rmtr1210.01210.04.0FalseNoneNoneFalseNoneFalse4840.00
3925434151381NoneMan938PIPES RUNNING THROUGH EXPOSED AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves and thickness of insulation as per Determine proper thickness recommendations (minimum Rvalue) for the thermal insulation as per latest edition of ASHRAE 90.1 or ECBC, whichever is stringent. This shall ensure minimum energy savings of 2040 BTU loss per hour per square foot. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement and proper self locking nylon zip ties black color in certain intervals. (Class 0 insulation to be used for outdoors will require protection from UV exposure). Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 22.23mm (OD)Rmtr1050.01050.060.0FalseNoneNoneFalseNoneFalse63000.00
3925435151381NoneMan939PIPES RUNNING THROUGH EXPOSED AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves and thickness of insulation as per Determine proper thickness recommendations (minimum Rvalue) for the thermal insulation as per latest edition of ASHRAE 90.1 or ECBC, whichever is stringent. This shall ensure minimum energy savings of 2040 BTU loss per hour per square foot. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement and proper self locking nylon zip ties black color in certain intervals. (Class 0 insulation to be used for outdoors will require protection from UV exposure). Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 19.05mm (OD)Rmtr900.0900.04.0FalseNoneNoneFalseNoneFalse3600.00
3925436151381NoneMan940PIPES RUNNING THROUGH EXPOSED AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves and thickness of insulation as per Determine proper thickness recommendations (minimum Rvalue) for the thermal insulation as per latest edition of ASHRAE 90.1 or ECBC, whichever is stringent. This shall ensure minimum energy savings of 2040 BTU loss per hour per square foot. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement and proper self locking nylon zip ties black color in certain intervals. (Class 0 insulation to be used for outdoors will require protection from UV exposure). Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 15.88mm (OD)Rmtr750.0750.060.0FalseNoneNoneFalseNoneFalse45000.00
3925437151381NoneMan941PIPES RUNNING THROUGH EXPOSED AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves and thickness of insulation as per Determine proper thickness recommendations (minimum Rvalue) for the thermal insulation as per latest edition of ASHRAE 90.1 or ECBC, whichever is stringent. This shall ensure minimum energy savings of 2040 BTU loss per hour per square foot. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement and proper self locking nylon zip ties black color in certain intervals. (Class 0 insulation to be used for outdoors will require protection from UV exposure). Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 12.70mm (OD)Rmtr580.0580.060.0FalseNoneNoneFalseNoneFalse34800.00
3925438151381NoneMan942REFRIGERANT PIPING: PIPES RUNNING INSIDE BUILDING AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves or sheet and thickness of insulation as per Design Basis Report. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement. Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 41.28mm (OD)Rmtr1400.01400.020.0FalseNoneNoneFalseNoneFalse28000.00
3925439151381NoneMan943PIPES RUNNING INSIDE BUILDING AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves or sheet and thickness of insulation as per Design Basis Report. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement. Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 38.1mm (OD)Rmtr1300.01300.01.0FalseNoneNoneFalseNoneFalse1300.00
3925440151381NoneMan944PIPES RUNNING INSIDE BUILDING AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves or sheet and thickness of insulation as per Design Basis Report. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement. Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 34.93mm (OD)Rmtr1300.01300.01.0FalseNoneNoneFalseNoneFalse1300.00
3925441151381NoneMan945PIPES RUNNING INSIDE BUILDING AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves or sheet and thickness of insulation as per Design Basis Report. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement. Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 31.8mm (OD)Rmtr1150.01150.01.0FalseNoneNoneFalseNoneFalse1150.00
3925442151381NoneMan946PIPES RUNNING INSIDE BUILDING AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves or sheet and thickness of insulation as per Design Basis Report. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement. Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 28.58mm (OD)Rmtr1150.01150.070.0FalseNoneNoneFalseNoneFalse80500.00
3925443151381NoneMan947PIPES RUNNING INSIDE BUILDING AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves or sheet and thickness of insulation as per Design Basis Report. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement. Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings: 25.4mm (OD)Rmtr1050.01050.01.0FalseNoneNoneFalseNoneFalse1050.00
3925444151381NoneMan948PIPES RUNNING INSIDE BUILDING AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves or sheet and thickness of insulation as per Design Basis Report. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement. Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 22.23mm (OD)Rmtr900.0900.080.0FalseNoneNoneFalseNoneFalse72000.00
3925445151381NoneMan949PIPES RUNNING INSIDE BUILDING AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves or sheet and thickness of insulation as per Design Basis Report. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement. Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 19.05mm (OD)Rmtr790.0790.01.0FalseNoneNoneFalseNoneFalse790.00
3925446151381NoneMan950PIPES RUNNING INSIDE BUILDING AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves or sheet and thickness of insulation as per Design Basis Report. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement. Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 15.88mm (OD)Rmtr655.0655.0140.0FalseNoneNoneFalseNoneFalse91700.00
3925447151381NoneMan951PIPES RUNNING INSIDE BUILDING AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves or sheet and thickness of insulation as per Design Basis Report. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement. Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 12.70mm (OD)Rmtr490.0490.0140.0FalseNoneNoneFalseNoneFalse68600.00
3925448151381NoneMan952PIPES RUNNING INSIDE BUILDING AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves or sheet and thickness of insulation as per Design Basis Report. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement. Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 9.53mm (OD)Rmtr390.0390.090.0FalseNoneNoneFalseNoneFalse35100.00
3925449151381NoneMan953PIPES RUNNING INSIDE BUILDING AREA : Supply, installation, testing and commisioning of hard soft drawn (Soft Annealed upto 15.9mm OD and Half Hard above 19.1mm OD) interconnecting refrigerant piping (Phosphoric Acid Deoxidized Seamless Copper Pipe) of various sizes as required for the full functionality of the VRF system (0.8mm 1.43mm). The thickness and material should comply with the design pressure 4.0Mpa (40bar). The brazing to be carried out with bleeding of nitrogen. The copper pipe to be insulated with Nitrile Rubber sleeves or sheet and thickness of insulation as per Design Basis Report. Ref pipes, cables etc to be laid in the G.I. Tray with proper supporting arrangement. Piping sizes (Liquid Line and Suction (Gas) Line) and lengths between indoor and outdoor units to be validated by VRV supplier based on the Shop Drawings : 6.35mm (OD)Rmtr370.0370.090.0FalseNoneNoneFalseNoneFalse33300.00
3925450151381NoneMan954CABLE TRAY FOR PIPE SUPPORTING : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5percent, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc as required. Cable tray lengths to be estimated by vendor : 600 mm width X 50 mm depth X 2.0 mm thicknessRmtr765.0765.040.0FalseNoneNoneFalseNoneFalse30600.00
3925451151381NoneMan955CABLE TRAY FOR PIPE SUPPORTING : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5percent, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc as required. Cable tray lengths to be estimated by vendor: 450 mm width X 62.5 mm depth X 2.0 mm thicknessRmtr700.0700.040.0FalseNoneNoneFalseNoneFalse28000.00
3925452151381NoneMan956CABLE TRAY FOR PIPE SUPPORTING : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5percent, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc as required. Cable tray lengths to be estimated by vendor : 300 mm width X 62.5 mm depth X 2.0 mm thicknessRmtr621.0621.090.0FalseNoneNoneFalseNoneFalse55890.00
3925453151381NoneMan957CABLE TRAY FOR PIPE SUPPORTING : Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5percent, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts and nuts, painting suspenders etc as required. Cable tray lengths to be estimated by vendor: 150 mm width X 50 mm depth X 1.6 mm thicknessRmtr531.0531.0110.0FalseNoneNoneFalseNoneFalse58410.00
3925454151381NoneMan958Supply of Multi Kits Connection Kits Refnet joints branch distributors for indoor and outdoor units.Nos1150.01150.040.0FalseNoneNoneFalseNoneFalse46000.00
3925455151381NoneMan959Gas charging, Testing and commissioning with R410AKgs1050.01050.0110.0FalseNoneNoneFalseNoneFalse115500.00
3925456151381NoneMan960Supply and installation of GI conduit for the interconecting above cable between indoor units and outdoor units, between indoor units and remote controllers.Lot27500.027500.04.0FalseNoneNoneFalseNoneFalse110000.00
3925457151381NoneMan961VRV CONTROLLERS : Master Central Controller Central Remote Controller Master Central Controller Central Remote Controller with open protocol as specified below and in Technical Specifications suitable for automatic operation of all indoor and outdoor units. The central controller shall have a liquid crystal display (LCD) and have the capability of controlling all indoor and outdoor units individually, in groups and unanimously. The central controller shall have the unique capability of arranging indoor units into groups (up to 16 groups per network). The central controller shall be time clocked by the 7dayYear round programmable timer supplied by the manufacturer or by an external time clock (supplied by others). When used in conjunction with the 7day programmable timer then different programme on off times for each group of indoor units shall be available. Incase of BMS system not in operation for any reason, the Master Controller   Central Controller shall be capable to work on stand alone basis and should be able to indicate and control all indoor and outdoor units as specified. The system shall have the capability to connect to external printer.Lot54450.054450.04.0FalseNoneNoneFalseNoneFalse217800.00
3925458151381NoneMan962Interface Unit between VRV VRF and BMS : Intelligent Central Touch controller to control (switchin on and switching off with read write permission) and monitor ON OFF status of all the IDUs from one place with control wiring from the central controllers to individual ODUs complete with Modbus, Bacnet and Lonwork gateway suitable for third party BMS Integration.Lot135250.0135250.04.0FalseNoneNoneFalseNoneFalse541000.00
3925459151381NoneMan963Supply, fabrication and installation of GI Ducting Along with flanges,supports and all fixing materials : Factory fabricated Galvanized sheet metal duct work including bends, stiffners, flanges, guide vanes and supporting system (with fully threaded G.I. rods and M.S. slotted angles upto 600mm and above with 25x25x3 or higher MS to consider) complete with flanges, gaskets and supports etc., ducts to be fabricated erected as per SMACNA. The minimum weight of zinc coating (total on both sides) shall be 120 GSM as per latest version of IS:277. Interlocking system from one branch duct to other branch duct with TDF Flanges or to be specified : Thickness 0.63 mm Sheet 24 gaugeSqm1901.551901.55300.0FalseNoneNoneFalseNoneFalse570465.00
3925460151381NoneMan964Supply,fabrication and installation of GI Ducting Along with flanges,supports and all fixing materials : Factory fabricated Galvanized sheet metal duct work including bends, stiffners, flanges, guide vanes and supporting system (with fully threaded G.I. rods and M.S. slotted angles upto 600mm and above with 25x25x3 or higher MS to consider) complete with flanges, gaskets and supports etc., ducts to be fabricated erected as per SMACNA. The minimum weight of zinc coating (total on both sides) shall be 120 GSM as per latest version of IS:277. Interlocking system from one branch duct to other branch duct with TDF Flanges or to be specified : Thickness 0.80 mm Sheet 22 gaugeSqm2227.052227.05275.0FalseNoneNoneFalseNoneFalse612438.750
3925461151381NoneMan965Supply,fabrication and installation of GI Ducting Along with flanges,supports and all fixing materials : Factory fabricated Galvanized sheet metal duct work including bends, stiffners, flanges, guide vanes and supporting system (with fully threaded G.I. rods and M.S. slotted angles upto 600mm and above with 25x25x3 or higher MS to consider) complete with flanges, gaskets and supports etc., ducts to be fabricated erected as per SMACNA. The minimum weight of zinc coating (total on both sides) shall be 120 GSM as per latest version of IS:277. Interlocking system from one branch duct to other branch duct with TDF Flanges or to be specified : Thickness 1.00 mm Sheet 20 gaugeSqm2410.02410.0150.0FalseNoneNoneFalseNoneFalse361500.00
3925462151381NoneMan966Supply,fabrication and installation of GI Ducting Along with flanges,supports and all fixing materials : Factory fabricated Galvanized sheet metal duct work including bends, stiffners, flanges, guide vanes and supporting system (with fully threaded G.I. rods and M.S. slotted angles upto 600mm and above with 25x25x3 or higher MS to consider) complete with flanges, gaskets and supports etc., ducts to be fabricated erected as per SMACNA. The minimum weight of zinc coating (total on both sides) shall be 120 GSM as per latest version of IS:277. Interlocking system from one branch duct to other branch duct with TDF Flanges or to be specified : Thickness 1.25 mm Sheet 18 gaugeSqm2610.02610.010.0FalseNoneNoneFalseNoneFalse26100.00
3925463151381NoneMan967Gripple Support : Supply, Fabrication, installation and testing of Gripple Hangers, Supports and Modular system -Wire rope Supports Gripple (double channel wedge lock, unlocking device should not be integral part of grip for added safety) complete with end fixing. Wire Hangers shall be independently tested by reputed third party testing organization to sustain safe working load for 120min at elevated temperature of 175 deg. C or above. System shall be in accordance with the approved shop drawings and as required by the specifications. Kit including wire for safe working to be considered, Precrimpted Wire rope to be used along with GHF kit and Accessories for installation completeLot13150.013150.02.0FalseNoneNoneFalseNoneFalse26300.00
3925464151381NoneMan968VOLUME CONTROL DAMPER : G.I Volume Control Damper, Motorized (ONOFF Type) duct mounted GI volume control damper with enthalpy sensor and necessary control wire (minimum 1.5 sqmm) for integration within AHU room Make: SYSTEMAIR, CAMDUCT, CARYAIRE.Sqm4300.04300.05.5FalseNoneNoneFalseNoneFalse23650.00
3925465151381NoneMan969Damper ActuatorNos4307.04307.010.0FalseNoneNoneFalseNoneFalse43070.00
3925466151381NoneMan970VOLUME CONTROL DAMPER FIRE DAMPER : Supplying Fixing, testing and commissioning of fire dampers in supply air dut main branch and return air path as and where required of required sizes i c control wiring, the damper shall be motorized and spring return so as to close the damper in the event of power failure automatically and open the same in case of power being restored. The spring return action shall be inbuilt mechanism and not externally mounted. The damper shall also be closed in the event of fire signal complete as required and as per specification Make: SYSTEMAIR, CARYAIRE, JAYDE UTILITY, AIRMASTER. Fire DamperSqm6854.06854.03.0FalseNoneNoneFalseNoneFalse20562.00
3925467151381NoneMan971Actuator 10 Nm Make: Johnson controls, BELIMO.Nos6307.06307.05.0FalseNoneNoneFalseNoneFalse31535.00
3925468151381NoneMan972Control panel and Temprature SensorNos2285.02285.06.0FalseNoneNoneFalseNoneFalse13710.00
3925469151381NoneMan973LINEAR GRILLES Diffusers : Supply and fixing of powder coated extruded alluminium grill suitable for supply return air including all fixing hardware etc,. Complete. Color of the grille as per approval of Architect Client: 6inches excluded aluminium grill with 15 deg to 30 deg louversRmtr1787.11787.140.0FalseNoneNoneFalseNoneFalse71484.00
3925470151381NoneMan974Supply and fixing of powder coated extruded alluminium grill suitable for supply return air including all fixing hardware etc,. Complete. Color of the grille as per approval of Architect Client : 6inches aluminium spot grill with 15 deg to 30 deg louvers of size (450X150)Nos800.0800.04.0FalseNoneNoneFalseNoneFalse3200.00
3925471151381NoneMan975Supply and fixing of powder coated extruded alluminium grill suitable for supply return air including all fixing hardware etc,. Complete. Color of the grille as per approval of Architect Client: 6inches aluminium spot grill with 15 deg to 30 deg louvers of size (600X150)Nos920.0920.04.0FalseNoneNoneFalseNoneFalse3680.00
3925472151381NoneMan976Powder coated, extruded aluminium, supply air Jet diffusers with adjustable vanes of aluminium construction of 250mm dia. The diffuser shall be mounted in the GI box, with inlet connector suitable for flexible duct. GI Box and Flexible duct quantified seperately.Nos6480.06480.030.0FalseNoneNoneFalseNoneFalse194400.00
3925473151381NoneMan977Spill Air Boxes Expansion Plenum 450x 450 x 400 mm High Sheet Metal Spill air boxes made out of 26 GI sheet for connecting the diffuser outlet and flexibleNos1300.01300.030.0FalseNoneNoneFalseNoneFalse39000.00
3925474151381NoneMan978Supply and installtion of Powder coated aluminium diffusers of size 595x595mm for supply and return air.Nos5331.95331.930.0FalseNoneNoneFalseNoneFalse159957.00
3925475151381NoneMan979FRESH AIR LOUVER : Supply, installation and testing of Aluminium opposed blades fresh air of inlet louvers, bird screen, volume control damper in accordance with approved shop drawings and specifications.Sqm11250.011250.02.0FalseNoneNoneFalseNoneFalse22500.00
3925476151381NoneMan980G.I collar dampers with opposed blades as follows. Rate per sq.mt of face area.Sqm2755.22755.24.0FalseNoneNoneFalseNoneFalse11020.80
3925477151381NoneMan981ACOUSTIC LINING (DUCTS): Supply, Installation and Acoustic lining of ducting with 15mm thick open cell nitrile rubber insulation Class inches1inches existing surface, adhesive (K414), accessories with aluminium tape complete as required.Sqm1050.01050.0200.0FalseNoneNoneFalseNoneFalse210000.00
3925478151381NoneMan982Supplying, fixing acoustic lining on wall and ceiling of AHU rooms with 50mm thick, density 32 kg cu.m resin bonded glass fiber insulation friction fixed in 610mm X 610mm frame work made of 25 X 50 X 50 X 50 X 25 mm made out of 0.6mm thick GI sheet u shaped channel and covered with reinforced fiber glass tissue and finished with 0.80 mm perforated aluminium sheet etc. complete as required and as per specifications.Sqm864.0864.075.0FalseNoneNoneFalseNoneFalse64800.00
3925479151381NoneMan983THERMAL INSULATION: Supply and fixing of Thermal insulation of following thickness aluminium foil of mat finish closed cell Nitrile rubber (Class inchesOinches) insulation on existing duct after applying two coats of cold setting adhesive (CPRX compound). The joints shall sealed with 50mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. Make: KFLEX, SUPREME, PARAMOUNT : 9mmSqm620.0620.0325.0FalseNoneNoneFalseNoneFalse201500.00
3925480151381NoneMan984THERMAL INSULATION: Supply and fixing of Thermal insulation of following thickness aluminium foil of mat finish closed cell Nitrile rubber (Class inchesOinches) insulation on existing duct after applying two coats of cold setting adhesive (CPRX compound). The joints shall sealed with 50mm wide and 3mm thick self adhesive nitrile rubber tape insulation complete as per specifications and as required. Make: KFLEX, SUPREME, PARAMOUNT : 15mmSqm728.0728.0350.0FalseNoneNoneFalseNoneFalse254800.00
3925481151381NoneMan985Supply and installation Underdeck (Insulation) of specified thickness of Elastromeric Rubber Insulation Joints should be sealed with 50 mm wide 3 mm thick self adhesive tape Class inchesOinches Material(16mm thick) Make: KFLEX, SUPREME, PARAMOUNT.Sqm560.0560.01100.0FalseNoneNoneFalseNoneFalse616000.00
3925482151381NoneMan986Supply and Instalation of UPVC Drain water piping with Closed Cell Nitrile rubber insulation of 6mm with suitable clamping and bonding material as per ECBC Complaince: 25mm UPVCRmtr260.0260.0140.0FalseNoneNoneFalseNoneFalse36400.00
3925483151381NoneMan987Supply and Instalation of UPVC Drain water piping with Closed Cell Nitrile rubber insulation of 6mm with suitable clamping and bonding material as per ECBC Complaince : 40mm UPVCRmtr350.0350.070.0FalseNoneNoneFalseNoneFalse24500.00
3925484151381NoneMan988Supply and Instalation of UPVC Drain water piping with Closed Cell Nitrile rubber insulation of 6mm with suitable clamping and bonding material as per ECBC Complaince : 50mm UPVCRmtr410.0410.050.0FalseNoneNoneFalseNoneFalse20500.00
3925485151381NoneMan989All necessary civil works like cutting and chasing of walls floor glass etc. and make them good thereof.Lot20000.020000.06.0FalseNoneNoneFalseNoneFalse120000.00
3925486151381NoneMan990Supplying of…TR split Air conditioners suitable for operation on A C supply single phase 50 Hz 230 Volts with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit. The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube. (High wall chorded chordless). 5 Star Rating : 1.0 TRNos43791.343791.33.0FalseNoneNoneFalseNoneFalse131373.90
3925487151381NoneMan991Supplying of…TR split Air conditioners suitable for operation on A C supply single phase 50 Hz 230 Volts with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit. The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube. (High wall chorded chordless). 5 Star Rating : 1.5 TRNos50067.1550067.152.0FalseNoneNoneFalseNoneFalse100134.30
3925488151381NoneMan992Supplying of…TR split Air conditioners suitable for operation on A C supply single phase 50 Hz 230 Volts with hermetically sealed compressor with air cooled condenser, motor capacitor and start run capacitors, relay and over load protector internal unit, with one indoor and one outdoor unit. The condenser unit will be placed outside the room on the terrace to avoid noise including standard length of suitable size copper tubing covered with insulation tube. (High wall chorded chordless). 5 Star Rating : 2.0 TRNos56750.456750.42.0FalseNoneNoneFalseNoneFalse113500.80
3925489151381NoneMan993Installation charges for split type air conditioner with allied works for one indoor and one outdoor unit is to be mounted on suitable Angle Iron support up to 3.0 ton split cassette type A C.No3333.753333.757.0FalseNoneNoneFalseNoneFalse23336.250
3925490151381NoneMan994Supplying and installation of insulated refrigrent copper tubing of 5 8inches and 3 8inches with polythene foam insulation 3 core 80 stand copper wiring between indoor and outdoor unit. Leak testing oil and gas charging for additional piping length of tube : Copper PipingRmtr1626.451626.45140.0FalseNoneNoneFalseNoneFalse227703.00
3925491151381NoneMan995Hi wall suitable size CablingRmtr1667.01667.0180.0FalseNoneNoneFalseNoneFalse300060.00
3925492151381NoneMan996Insulated Drain piping with 9mm thick nitrile rubberRmtr160.0160.050.0FalseNoneNoneFalseNoneFalse8000.00
3925493151381NoneMan997Stabilizer 3kva, 4kva and 5kva as requiredNos2150.02150.07.0FalseNoneNoneFalseNoneFalse15050.00
3925494151381NoneMan998Extra for Fabrication supply and fixing of Stand fabricated using slotted angle L.angle of size 6mm x 50mm for mounting outdoor Indoor AC unit.Kgs120.0120.035.0FalseNoneNoneFalseNoneFalse4200.00
3925495151381NoneMan999Supplying and filling refrigerent (F22 F 12) for air conditioning equipments. Which includes the labour and Nitrogen gas for pressure and leak testing.Kg635.25635.2560.0FalseNoneNoneFalseNoneFalse38115.00
3925496151381NoneMan1000VENTILATION SYSTEMS (TOILET EXHAUST SYSTEM) : Supply, Installation, Testing and Commissioning of the following items as per specifications, drawings and equipment schedule. Supply fans and Exhaust fans, Single skin ventilation unit with backward curved forward curved centrifugal DIDW fan, cleanable pre filter 90percent effieciency down to 10 micron and outlet dampers with fire retarding canvas connection. Outlet velocity shall be less than 9.5 m s and Suitable for out door applications. (Static pressures given in schedules are for guidance only. The Contractor shall calculate the external and internal static pressure of all fans and submit the same for approval prior to ordering. Any increase of fan static motor power required shall be at no additional cost to client.) : 1200 CFM and 30 mm.wc ESP (Exhaust Air)No27800.027800.08.0FalseNoneNoneFalseNoneFalse222400.00
3925497151381NoneMan1001VENTILATION SYSTEMS (TOILET EXHAUST SYSTEM) : Supply, Installation, Testing and Commissioning of the following items as per specifications, drawings and equipment schedule. Supply fans and Exhaust fans, Single skin ventilation unit with backward curved forward curved centrifugal DIDW fan, cleanable pre filter 90percent effieciency down to 10 micron and outlet dampers with fire retarding canvas connection. Outlet velocity shall be less than 9.5 m s and Suitable for out door applications. (Static pressures given in schedules are for guidance only. The Contractor shall calculate the external and internal static pressure of all fans and submit the same for approval prior to ordering. Any increase of fan static motor power required shall be at no additional cost to client.) : 1500 CFM and 30 mm.wc ESP (Exhaust Air)No24950.024950.05.0FalseNoneNoneFalseNoneFalse124750.00
3925498151381NoneMan1002Insulated Flexible Ducts with Inner core made of Aluminum laminate and Polyester film with latex adhesive supported by helically wound, springsteel wire Outer jacket made of UL 181, Class 1, fibrousglass insulation, Polyethylene vaporbarrier film necessary accossories. Thickness of insulation shall be as per ASHRAE 90.1. Minimum width of the supporting strap to be 25mm. For 150 to 300mm dia (PWD Ele SR 22324 Pg No. 558 of 635 6.29.4)Rmtr1776.61776.6150.0FalseNoneNoneFalseNoneFalse266490.00
3925499151381NoneMan1003Supply, installation, testing and balancing of square Rectangular Aluminium powder coated Exhaust air diffusers. All diffusers must be multislotted complete with air pattern controller, Removable key. 150mmx150mm Exhaust air.Nos1150.01150.0155.0FalseNoneNoneFalseNoneFalse178250.00
3925500151381NoneMan1004Supply, Installation, Testing and Commissioning of 250mmx250mmx300mm hight diffuser boxes Mixing Boxes made out of 24 g GI sheet suitable for 150mm x 150mm outlet grilles, compete with spigot, supporting chain. (PWD Ele SR 22324 Pg No. 558 of 635 6.29.3)Nos6588.756588.75155.0FalseNoneNoneFalseNoneFalse1021256.250
3925501151381NoneMan1005Supply and Installation and Commissioning of 22G GSS Butterfly damper a) 150mm DiaNos780.0780.0155.0FalseNoneNoneFalseNoneFalse120900.00
3925502151381NoneMan1006Supply, installation, testing and commissing of INLINE FANS for ventilation system. Each fan shall be complete with totally enclosed fan cooled motor drive, motor mount , vibration isolators and suitable weather protection arrangement. Fan static pressure at 20mm and 300CFM.Nos10800.010800.05.0FalseNoneNoneFalseNoneFalse54000.00
3925503151381NoneMan1007Supply, installation, testing and commissing of INLINE FANS for ventilation system. Each fan shall be complete with totally enclosed fan cooled motor drive, motor mount , vibration isolators and suitable weather protection arrangement. Fan static pressure at 20mm and 600CFMNos14800.014800.05.0FalseNoneNoneFalseNoneFalse74000.00
3925504151381NoneMan1008Supply and fixing of powder coated extruded alluminium grill suitable for supply return air including all fixing hardware etc,. Complete. Color of the grille as per approval of Architect Client : 6inches aluminium spot grill with 15 deg to 30 deg louvers of size (200X100)Nos600.0600.05.0FalseNoneNoneFalseNoneFalse3000.00
3925505151381NoneMan1009Door Air Curtains (DAC) : Air Velocity : 25 m s at the mouth of the Air Curtain and 4 m s at the floor, Sound Level 45DB at 1Meter above the Ground Level, 1 Phase Motor, 220 Volts, 50 Hz, 1440 RPM, Double end shaft Balanced on sealed Ball Bearings, Impellers 220 mm Dia, 42 Blades, 485 635 mm in length, Grade SS304, Stainless Steel Make, Dynamically balanced, Outer Casing C.R.C.A Sheet, Powder coated and of approved Colour, Louvers M.S.Make, Powder Coated and can be tilted at 7.5 Degrees inside or outside to adjust airflow, Bearings with approved make and sealed ball bearing : Door Air curtain suitable for a door width of 1.8 m. and height of 2.4 m.No38600.038600.09.0FalseNoneNoneFalseNoneFalse347400.00
3925506151381NoneMan1010Door Air Curtains (DAC) : Air Velocity : 25 m s at the mouth of the Air Curtain and 4 m s at the floor, Sound Level 45DB at 1Meter above the Ground Level, 1 Phase Motor, 220 Volts, 50 Hz, 1440 RPM, Double end shaft Balanced on sealed Ball Bearings, Impellers 220 mm Dia, 42 Blades, 485 635 mm in length, Grade SS304, Stainless Steel Make, Dynamically balanced, Outer Casing C.R.C.A Sheet, Powder coated and of approved Colour, Louvers M.S.Make, Powder Coated and can be tilted at 7.5 Degrees inside or outside to adjust airflow, Bearings with approved make and sealed ball bearing : Door Air curtain suitable for a door width of 4.0 m. and height of 2.4 m.No86500.086500.04.0FalseNoneNoneFalseNoneFalse346000.00
3925507151381NoneMan1011Prefabricated plenums made out of PUF panels of approved sizes. The plenums shall be constructed with 24G sheet as outer layer and 24G sheet as inner layer with 50mm thick injected PUF of 2432kg cubmet density. All the corners shall be provided with extruded aluminium section and necessary support for hanging the plenums in all the corners. All the opening made for connecting the ducts shall be sealed properly with necessary aluminium sections and riveted at regular intervals. The outer layer shall be pasteurized finish.Sqm2400.02400.070.0FalseNoneNoneFalseNoneFalse168000.00
3925508151381NoneMan1012Fire proof double layered silicon coated fabric, air tight, water proof (Outdoor type installation), to with stand high temprature, non flamable type, canvass cloth connection for above AHU outlet complete with drawn aluminum flanges on both sides for connection to AHU and duct complete with nuts, bolts etc. as per specification. Make:Nos2951.12951.15.0FalseNoneNoneFalseNoneFalse14755.50
3925509151381NoneMan1013BASEMENT VENTILATION SYSTEMS (FRESH AIR AND EXHAUST SYSTEM) : Supply, installing, testing and commissioning of Ductless Ventilation Jet fans Centrifugal as per specifications for normal ventilation and Smoke Extraction application. The complete fan assembly with its Casing, impeller and motor (not only the motor) shall be imported from manufacturer and certified as tested for 300 Deg C for 2 hours operation. The Jet fans casing shall be made of Hot Dipped Galvanized Steel. The Motorshall be dual speed and run on the electrical power suitable for 415V 3 Ph 50Hz. The Jet fans shall be of 3000 1500 CFM capacity.The Jet fan shallbe as per technical specification and of approved make Nicotra,Systemair, Greenheck.Nos48700.048700.018.0FalseNoneNoneFalseNoneFalse876600.00
3925510151381NoneMan1014CFD Analysis ( for basement for CO2 simulation)Lot110000.0110000.01.0FalseNoneNoneFalseNoneFalse110000.00
3925511151381NoneMan1015CO Sensors: Supply of CO Sensors shall be designed to detect CO gas in the air with sensing range between 0300 ppm with high accuracy at low connection( 1 Sensor for 2 fans). Basement 1.Nos13210.013210.09.0FalseNoneNoneFalseNoneFalse118890.00
3925512151381NoneMan1016Supply, Installation, Testing and Commissioning of Electrical Panel with built in PLC for Basement floors with necessary starters for 18Nos of Jet Fans 4Nos of Ventilation fans and 9Nos of CO Sensors. Each of the jet fans (Dual speed motors) for demand ventilation with a logic based on CO detectors. Should also enable auto on off of fans for power saving BASED ON SENSING OF CO LEVEL including all necessary cabling for the above fans and complete. make:GV Control panel, Emmanuel, VKA Power master.Nos352875.0352875.01.0FalseNoneNoneFalseNoneFalse352875.00
3925513151381NoneMan1017Axial Flow Ventilation Fans (Normal and Fire Mode) : SITC of AMCA rated Extract air fans of Tube axial type complete with direct drive fire rated motor with protection, fire rated electrical accessories and other ancillaries. The Fan, motor and each component shall be Fire rated and designed to with stand 300 degree C temperatures for 2 hours in the event of fire. Noise levels of the fans in pollution mode shall be within acceptable levels of 84 dba at 3m distance. Each fan shall be with fixing frame and supports for installation on wall inside the shaft. The scope shall include all ancillary works related to proper fixing of the fans. Fan construction and technical performance shall be with PLC panel for the below with necessary cabling to be considered during quoting in complete compliance with the technical specification issued in Tender.The Fan, motor and each component of the fan shall be Fire rated as per IEC EN NFPA standards and fully meet the F300 time temperature classifications of EN 121013 (250 degree C for 120 minutes). Test Certificates to be produced prior to delivery of the units. Fan motor shall be of 6pole, high efficiency and low noise design. The fan shall be acousticaly treated and Fan supplied with cushy foot(Spring isolator). Accessories , 2 nos of Matching Flanges and 2 Nos fire rated canvas connection. Make Axial flow fan: Nicotra, Systemair, Greenheck : Fan Capacity rating: 11500 23000 CFM at 30 mmwg Static Pressure (Dual Speed Motor)Nos217488.0217488.02.0FalseNoneNoneFalseNoneFalse434976.00
3925514151381NoneMan1018TUBE AXIAL FANS FOR FRESH AIR : Long cased Smokespill Tube Axial fan with AMCA certification (For AIR, SOUND Performance and FEG). The Long casing shall comprise of adjustable blade angles to deliver the design air quantity. The axial fan assembly shall be housed in a casing made of Powder coated Mild Steel, adjustable pitch die cast aluminium impeller (Hub and blades) suitable for 415V 3Ph 50Hz AC supply. Fan position shall be as per the tender drawings. The Motor shall be of TEFC TEOA, IP55 protection, Class F insulation, IE2 efficiency, suitable for 3 phase, 415volts, 50hz power supply. Fan position shall be as per the tender drawings. AMCA certificate to be provided along with technical submittals Long Casing should be made of powder coated Mild Steel. The unit shall be suitable for indoor application with necessary supports with necessary MS channels and threaded rods. Make Axial flow fan: Nicotra, Systemair, Greenheck : 23000 CFM 20 mm wc. ESP. Fresh Air (Motor rating 7.5 Kw 6 Pole)Nos175450.0175450.02.0FalseNoneNoneFalseNoneFalse350900.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17255165570000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17255165570000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17255165570000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of KPPP Portal on or before the last date and time of bid submission.None
17255165570000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17255165570000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17255165570000NoneNoneELIGIBILITYThe bidder shall bear all costs associated with the preparation and submission of his tender, and the employer will in no case be responsible and liable for those costs. The tender fee is non-refundable.None
17255165570000NoneNoneELIGIBILITYThe employer reserves the rights to reject one or all tenders without assigning any reason.None
17255165570000NoneNoneELIGIBILITYThe employer is not responsible for any delay in accessing KPPP portal.None
17255165570000NoneNoneELIGIBILITYTo qualify for award of this contract, each tenderer should give all details and documents as per Technical and Financial bid attached to this tender.None
17255165570000NoneNoneELIGIBILITYAs per Karnataka state Government order LD/300/LET/2006 Bangalore dated 01.01.07 and Government letter no PW/134/BMS/2007 dated 27.07.07, a sum amounting to 1% of the bill amount will be deducted towards constructions labour welfare fund.None
17255165570000NoneNoneELIGIBILITYAll the formats prescribed in the bid document shall be filled by the tenderer in complete manner otherwise it will be rejected.None
17255165570000NoneNoneELIGIBILITYAll the scanned documents pertaining to bidder to be uploaded shall be in original and same originals should be produced to the REGISTRAR, RGUHS (at the time of Technical Bid Opening) who reserves right to verify the original documents before approval.None
17255165570000NoneNoneELIGIBILITYAll the items in the tender include all lead, lifts, labour, loading, unloading, transportation, hire charges of machinery curing for concrete works, and all other incidental charges necessary for successful completion of works as per the direction of Engineer-in-charge of this work.None
17255165570000NoneNoneELIGIBILITYContractors should follow strictly prevailing rules of labour act.None
17255165570000NoneNoneELIGIBILITYIn case if the death of a contractor, after executing the agreement / commencement of the work, his legal heir, if an eligible registered contractor and is willing, can execute and complete the work, at the accepted tender rates, irrespective of the cost of the work.None
17255165570000NoneNoneELIGIBILITYThe Item rates quoted shall include cost of Royalty charges on construction materials and other taxes as per rates provided in prevailing Govt orders at the time of executionNone
17255165570000NoneNoneELIGIBILITYAll materials required for this work shall be procured by the bidder himself and should be got tested by the quality control authorities at his own cost before use on the work. Department will not supply any materials.None
17255165570000NoneNoneELIGIBILITYThe tenderer should submit proposed methodology and programme of construction backed with equipment and material planning, & deployment duly supported with broad calculation and quality management, plan, proposed to be adopted justifying their capability of execution and completion of the work as per technical specifications and within the stipulated period of completion.None
17255165570000NoneNoneELIGIBILITYMaterials like bitumen, steel, cement etc., required for the work shall be procured by the tenderer themselves and should get tested by the quality control authority at his cost before used on the work.None
17255165570000NoneNoneELIGIBILITYAll documents should be uploaded by the contractor is to be attested by the authorized notary or an officer not below the rank of Executive Engineer and should be produced for verification at any stage of process as and when sought for. Failure to produce original documents leads to rejection of Tender.None
17255165570000NoneNoneELIGIBILITYFinancial Year will be reckoned as the period between first day of April and Thirty-first day of March of succeeding year (both days inclusive).None
17255165570000NoneNoneELIGIBILITYAll safety precautions, warning signs, night illumination, reflectors, deployment of security guards has to be ensured so that no untoward incident happens on account of negligence or any project activity. Contractor should indemnify the client to that extent.None
17255165570000NoneNoneELIGIBILITYUnits, Rates & Prices shall be quoted by the tender in Indian Rupees onlyNone
17255165570000NoneNoneELIGIBILITYItem for which no rates or price has been entered in will not be paid for by the Employer when executed & shall be deemed covered by the other rates & prices in the bill of quantities.None
17255165570000NoneNoneELIGIBILITYTenderer shall obtain the Work done Certificate in the prescribed format from the Competent Authority not below the rank of Executive Engineer (District Level Officer) and scan the Original Certificate and attach the scanned file to the tender. The Original Certificate shall be produced at the time of opening of Technical Bids for physical verification.None
17255165570000NoneNoneELIGIBILITYThe field Lab /Mobile Lab shall be preferably located, adjacent to the site with the required amenities as per the clause. Failing which 1 percent of the amount of work done will be penalized.None
17255165570000NoneNoneELIGIBILITYTenderers are requested to read the Bid documents carefully and upload the necessary documents before submission of their bid.None
17255165570000NoneNoneELIGIBILITYTo qualify for award of this Contract, each tenderer should give all details and documents as per KW-4None
17255165570000NoneNoneELIGIBILITYConstruction of Regional Centre along with skill labs, research labs and Indoor sports Facilities for RGUHS at Mangalore is a Special Category Building Construction Work & the tenderer has to visit the site and has to submit the feasibility report to know the nature of work and working conditions. They should submit consent letter counter signed by Registrar, RGUHS Bangalore and should be uploaded it in the KPPP along with the bid. Failing to upload the consent letter will make the tenderer liable for rejection on Site Condition status. Consent letter counter signed by the Registrar, RGUHS is Mandatory.None
17255165570000NoneNoneELIGIBILITYFurther particulars, if any, required by the Contractor can be had from the Engineering Section of RGUHS, during office hours on all working days. It may be noted that if any of the dates mentioned above happened to be a general holiday the next working day will holds good in lieu of the dates mentioned.None
17255165570000NoneNoneELIGIBILITYThe contractor should maintain the work during the defect liability period, i.e. for 1 year after the completion of work at his own cost.None
17255165570000NoneNoneELIGIBILITYConsent letter of Building Construction Works expert in original with date shall be submitted duly signed in ink along with the technical bidsNone
17255165570000NoneNoneELIGIBILITYThe Bidders shall note that the information furnished in technical Bid will be evaluated with respect to the Technical requirement Criteria set forth in the Bid Document, which is uploaded separately. The Bids meeting the minimum Technical criteria at the discretion of the Engineer-in-Charge shall only be qualified for financial Evaluation of Financial Bids.None
17255165570000NoneNoneELIGIBILITYContractors should be registered with CPWD & KPWD as Class-I, Registration and the tenderer should submit the Registration Certificate along with technical bidNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneAs per Tender DocumentOthersAs per tender document
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- As per Tender Document
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Achieved in at least two financial years a Minimum financial turn over in all classes of civil engineering construction works only of Rs 8000.00 lakhs.TrueTechnical Bid
Satisfactorily completed, as a prime contractor, for at least one similar work comprising RCC framed structures multi storied Building with at least G Plus 3 floors having a built-up area of 8000 Sqm in a single Project building including Civil, Plumbing, Water Supply, sanitary, Electrical, Firefighting, Lift works and infrastructure development works to an extent of value not less than Rs. 3200.00 lakhs in a single work.TrueTechnical Bid
Executed in any one year, the following minimum quantities of work as per the schedule usually of the peak annual rate of constructionTrueTechnical Bid
The tenderer or his identified sub-contractor should possess valid License for executing building electrification work and should have executed One similar electrical works for buildings totaling not less than Rs. 275.00 lakhs in any one yearTrueTechnical Bid
The tenderer or his identified sub-contractor should possess valid license for executing water supply or sanitary Engineering works and should have executed One similar water supply or sanitary Engineering works for buildings totaling not less than Rs. 47.00 lakhs in any one year.TrueTechnical Bid
The tenderer or his identified sub-contractor should have executed one similar Firefighting works totaling not less than Rs. 25.00 lakhs in any one year.TrueTechnical Bid
The tenderer or his identified sub-contractor should have executed one similar HVAC works totaling not less than Rs. 85.00 lakhs in any one year.TrueTechnical Bid
liquid assets and or availability of credit facilities of not less than Rs. 1240.00 Lakhs Credit lines or letter of credit or certificates from nationalized banks for meeting the fund requirement etc. in the prescribed format.TrueTechnical Bid
Certification of registration in the labor department. All labor employed by the contractor shall be got registered with Karnataka Construction Labor Welfare Board, ESIC and EPF, etc,TrueTechnical Bid
As per tender documentTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1725517938000
version0
createdDateNone
modifiedDateNone
blockNumberOffice of the Registrar, RGUHS, Bengaluru
streetNone
cityBengaluru
stateKarnataka
pin560041
tenderRecallDTONone