3907639 | 150692 | None | SBM-01 | KSRB 1-1.1: Earth work in surface excavation for stripping, seating of bund, Road way by manual means for lowering & levelling the ground for all works other than foundation & depth in Ordinary rock and soft rock upto 300mm depth as per drawing and technical specifications, including setting out, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. | Cum | 575.0 | 575.0 | 988.65 | False | None | None | False | None | False | 568473.75 | 0 |
3907640 | 150692 | None | SBM-02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In all kinds of soils Depth upto 3 m. | Cum | 102.0 | 102.0 | 201.28 | False | None | None | False | None | False | 20530.56 | 0 |
3907641 | 150692 | None | SBM-03 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications | Sqm | 118.0 | 118.0 | 621.65 | False | None | None | False | None | False | 73354.7 | 0 |
3907642 | 150692 | None | SBM-04 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant ISCodes machine mixed, laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates. | Cum | 5664.0 | 5664.0 | 114.52 | False | None | None | False | None | False | 648641.28 | 0 |
3907643 | 150692 | None | SBM-05 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . including cost of material, labour, usage charges complete as per specifications. | Cum | 6389.0 | 6389.0 | 62.33 | False | None | None | False | None | False | 398226.37 | 0 |
3907644 | 150692 | None | SBM-06 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar worksetc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to50 m and lift upto 1.5 m. | Cum | 266.0 | 266.0 | 290.55 | False | None | None | False | None | False | 77286.3 | 0 |
3907645 | 150692 | None | SBM-07 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates(The cost of steel reinforcement & formwork to be paid separately). | Cum | 6336.0 | 6336.0 | 54.31 | False | None | None | False | None | False | 344108.16 | 0 |
3907646 | 150692 | None | SBM-08 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works& super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement, dowel bars & formwork to be paid separately) | Cum | 6843.0 | 6843.0 | 3.16 | False | None | None | False | None | False | 21623.88 | 0 |
3907647 | 150692 | None | SBM-09 | Providing Removing of Foundations, footings bases of columns Shuttering & Form Work etc., complete. 8 Percentage on finished rate of concrete per m3(rate 6521.55x 8% = 532.22 ) | Sqm | 532.22 | 532.22 | 80.4 | False | None | None | False | None | False | 42790.488 | 0 |
3907648 | 150692 | None | SBM-10 | Providing Removing of vertical surface such as walls at any thickness, including attached pilasters, buttresses, plinth cills and string courses cost of all materials, Shuttering & Form Work etc., complete. 20 Percentage on finished rate of concrete per m3 (rate 6794.55x 20% = 1437.03 )
(Pg no 115, slno 16, PWD Common SR Volume-I 2023-24) | Sqm | 1437.03 | 1437.03 | 14.93 | False | None | None | False | None | False | 21454.8579 | 0 |
3907649 | 150692 | None | SBM-11 | Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) | Kg | 84.0 | 84.0 | 6705.87 | False | None | None | False | None | False | 563293.08 | 0 |
3907650 | 150692 | None | SBM-12 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and(PWD Common SR Volume-II 2023-24 Pg No17, Item No-6.32) | Sqm | 1310.0 | 1310.0 | 545.32 | False | None | None | False | None | False | 714369.2 | 0 |
3907651 | 150692 | None | SBM-13 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 295.0 | 295.0 | 689.84 | False | None | None | False | None | False | 203502.8 | 0 |
3907652 | 150692 | None | SBM-14 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 354.0 | 354.0 | 751.87 | False | None | None | False | None | False | 266161.98 | 0 |
3907653 | 150692 | None | SBM-15 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charges. | Sqm | 89.0 | 89.0 | 751.87 | False | None | None | False | None | False | 66916.43 | 0 |
3907654 | 150692 | None | SBM-16 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.(Internal Walls) | Sqm | 105.0 | 105.0 | 689.84 | False | None | None | False | None | False | 72433.2 | 0 |
3907655 | 150692 | None | SBM-17 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade: One coats on old work as per specifications and as per directions of Engineer in charge. (Internal Painting) | Sqm | 86.1 | 86.1 | 689.84 | False | None | None | False | None | False | 59395.224 | 0 |
3907656 | 150692 | None | SBM-18 | KSRB 11-11.5.1:Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.5.1, Page No. 75, Vol.2) | Sqm | 4478.0 | 4478.0 | 15.12 | False | None | None | False | None | False | 67707.36 | 0 |
3907657 | 150692 | None | SBM-19 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance 1mm) with wall thickness 2.0 mm ( 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm ( 0.1 mm) wall thickness and 3 nos stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge. 48x40 mm PVC Extruded section (Item No. 12.83 Page No. 110 Vol.2 PWD SR 2021-22) | Sqm | 198.0 | 198.0 | 14.7 | False | None | None | False | None | False | 2910.6 | 0 |
3907658 | 150692 | None | SBM-20 | KSRB 12-12.92:Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made). (Item No. 12.92 Page No.112 Vol.2 PWD SR 2021-22) | Sqm | 6245.0 | 6245.0 | 14.7 | False | None | None | False | None | False | 91801.5 | 0 |
3907659 | 150692 | None | SBM-21 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 988.0 | 988.0 | 2.88 | False | None | None | False | None | False | 2845.44 | 0 |
3907660 | 150692 | None | SBM-22 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e.at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications. | Kg | 489.0 | 489.0 | 1045.44 | False | None | None | False | None | False | 511220.16 | 0 |
3907661 | 150692 | None | SBM-23 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 912.0 | 912.0 | 19.2 | False | None | None | False | None | False | 17510.4 | 0 |
3907662 | 150692 | None | SBM-24 | KSRB 11-11.16.3:Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Electric resistance or induction butt welded tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 122.0 | 122.0 | 36000.0 | False | None | None | False | None | False | 4392000.0 | 0 |
3907663 | 150692 | None | SBM-25 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 183.0 | 183.0 | 840.0 | False | None | None | False | None | False | 153720.0 | 0 |
3907664 | 150692 | None | SBM-26 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all
complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 113.0 | 113.0 | 335.79 | False | None | None | False | None | False | 37944.27 | 0 |
3907665 | 150692 | None | SBM-27 | Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge. 0.63 mm thick with zinc coating not less than 275 g/ m². | Sqm | 879.0 | 879.0 | 1077.3 | False | None | None | False | None | False | 946946.7 | 0 |
3907666 | 150692 | None | SBM-28 | Providing and fixing Ricron Panel: 18mm thick including cost of materials, labour complete as per specifications and as per directions of Engineer in-charge. | Sqm | 1517.0 | 1517.0 | 7.2 | False | None | None | False | None | False | 10922.4 | 0 |
3907667 | 150692 | None | SBM-29 | Providing and laying Cement concrete pavement with 1:2:4 for commercial & residential building floors, hardpaths, footpaths using 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size, including finishing complete as per Engineer incharge. | Sqm | 6666.0 | 6666.0 | 182.44 | False | None | None | False | None | False | 1216145.04 | 0 |
3907668 | 150692 | None | SBM-30 | VDF Charges | Sqm | 150.0 | 150.0 | 182.44 | False | None | None | False | None | False | 27366.0 | 0 |
3907669 | 150692 | None | SBM-31 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand),jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 1000x1000 mm. | Sqm | 1864.0 | 1864.0 | 390.0 | False | None | None | False | None | False | 726960.0 | 0 |
3907670 | 150692 | None | SBM-32 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 1076.0 | 1076.0 | 30.0 | False | None | None | False | None | False | 32280.0 | 0 |
3907671 | 150692 | None | SBM-33 | Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1392.0 | 1392.0 | 88.8 | False | None | None | False | None | False | 123609.6 | 0 |
3907672 | 150692 | None | SBM-34 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 2633.0 | 2633.0 | 28.0 | False | None | None | False | None | False | 73724.0 | 0 |
3907673 | 150692 | None | SBM-35 | Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Each | 24686.0 | 24686.0 | 1.0 | False | None | None | False | None | False | 24686.0 | 0 |
3907674 | 150692 | None | SBM-36 | Providing and fixing M.S. angle 50x50x5 mm to act as nosing with lugs of M.S. flat 10x5 mm, 10 cm long, forked at end 60cm apart (minimum three lugs to be provided), including necessary welding and applying a priming coat of approved primer on exposed surface etc. complete. | Sqm | 140.0 | 140.0 | 40.0 | False | None | None | False | None | False | 5600.0 | 0 |
3907675 | 150692 | None | SBM-37 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: | Each | 4884.0 | 4884.0 | 2.0 | False | None | None | False | None | False | 9768.0 | 0 |
3907676 | 150692 | None | SBM-38 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps: | Each | 3082.0 | 3082.0 | 2.0 | False | None | None | False | None | False | 6164.0 | 0 |
3907677 | 150692 | None | SBM-39 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975,50 Sqmm, 3.5 Core, (16 GI Strips - 4 x 0.8 mm) | Km | 178973.0 | 178973.0 | 0.75 | False | None | None | False | None | False | 134229.75 | 0 |
3907678 | 150692 | None | SBM-40 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff. 35 to 95 Sqmm | Km | 31139.0 | 31139.0 | 0.75 | False | None | None | False | None | False | 23354.25 | 0 |
3907679 | 150692 | None | SBM-41 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. I - Single Door 4 Way SP and N | No | 1241.0 | 1241.0 | 1.0 | False | None | None | False | None | False | 1241.0 | 0 |
3907680 | 150692 | None | SBM-42 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. III - Double Door 4 Way TP and N | No | 1400.0 | 1400.0 | 2.0 | False | None | None | False | None | False | 2800.0 | 0 |
3907681 | 150692 | None | SBM-43 | Supplying,fixing and wiring Residual current circuit breaker(RCCB)240/450V upto 300mA sensitivity on existing wood/ panel board 63 A 4 Pole | No | 5545.0 | 5545.0 | 2.0 | False | None | None | False | None | False | 11090.0 | 0 |
3907682 | 150692 | None | SBM-44 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP | No | 3082.0 | 3082.0 | 2.0 | False | None | None | False | None | False | 6164.0 | 0 |
3907683 | 150692 | None | SBM-45 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 A TPN | No | 3044.0 | 3044.0 | 4.0 | False | None | None | False | None | False | 12176.0 | 0 |
3907684 | 150692 | None | SBM-46 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 25mm dia 2 mm thick | Mtr | 78.0 | 78.0 | 200.0 | False | None | None | False | None | False | 15600.0 | 0 |
3907685 | 150692 | None | SBM-47 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary 32mm dia 2.5 mm thick | Mtr | 103.0 | 103.0 | 200.0 | False | None | None | False | None | False | 20600.0 | 0 |
3907686 | 150692 | None | SBM-48 | Supplying PVC flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely. 25mm | Mtr | 22.0 | 22.0 | 60.0 | False | None | None | False | None | False | 1320.0 | 0 |
3907687 | 150692 | None | SBM-49 | Supplying PVC flexible conduit pipe .... mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF screws and on either end of the pipe terminated completely. 32mm | Mtr | 29.0 | 29.0 | 30.0 | False | None | None | False | None | False | 870.0 | 0 |
3907688 | 150692 | None | SBM-50 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 1.5mm2 | Mtr | 26.0 | 26.0 | 200.0 | False | None | None | False | None | False | 5200.0 | 0 |
3907689 | 150692 | None | SBM-51 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 2.5mm2 | Mtr | 42.0 | 42.0 | 400.0 | False | None | None | False | None | False | 16800.0 | 0 |
3907690 | 150692 | None | SBM-52 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:2010 4mm2 | Mtr | 63.0 | 63.0 | 180.0 | False | None | None | False | None | False | 11340.0 | 0 |
3907691 | 150692 | None | SBM-53 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT greater than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiencygreater than 1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI and any Government certified agency & Design and Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and Cree/Nichia/ Lumileds/Osram make LED Source. 70 W | Each | 6768.0 | 6768.0 | 10.0 | False | None | None | False | None | False | 67680.0 | 0 |
3907692 | 150692 | None | SBM-54 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires | Each | 162.0 | 162.0 | 5.0 | False | None | None | False | None | False | 810.0 | 0 |
3907693 | 150692 | None | SBM-55 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70precentage, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment and impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiency greater than 1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI and any Government certified agency and Design and Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and Cree / Nichia / Lumileds / Osram make LED Source 40 W | Each | 4024.0 | 4024.0 | 8.0 | False | None | None | False | None | False | 32192.0 | 0 |
3907694 | 150692 | None | SBM-56 | Fixing charges of post top/ Gate/ Garden fitting /LED on the existing CI/ GI or any other pipe using required size of reducer, wiring using suitable wires | Each | 198.0 | 198.0 | 8.0 | False | None | None | False | None | False | 1584.0 | 0 |
3907695 | 150692 | None | SBM-57 | Supplying and Fixing of........mm dia class A GI pipe bracket upto 2ms long bent at suitable angle and fixing to this bracket street light fitting of all capacities to GI or GI or railor RCC pole/ wall using suitable clamps, bolts, and nuts and wiring using suitable capacity wires Using 32mm dia G.I.Pipe | Each | 1045.0 | 1045.0 | 8.0 | False | None | None | False | None | False | 8360.0 | 0 |
3907696 | 150692 | None | SBM-58 | Supplying and fixing surface/ flush mounting unbreakable PVC modular boxe suitable for mounting modular switch plate swith due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete 8 Way | Each | 219.0 | 219.0 | 2.0 | False | None | None | False | None | False | 438.0 | 0 |
3907697 | 150692 | None | SBM-59 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws, bolts nut setc.,complete on the existing metal/ PVC box 8 Way | Each | 219.0 | 219.0 | 5.0 | False | None | None | False | None | False | 1095.0 | 0 |
3907698 | 150692 | None | SBM-60 | Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board 6A SP Switch | Each | 55.0 | 55.0 | 6.0 | False | None | None | False | None | False | 330.0 | 0 |
3907699 | 150692 | None | SBM-61 | Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board 6A Three Way 5 pin Socket | Each | 115.0 | 115.0 | 6.0 | False | None | None | False | None | False | 690.0 | 0 |
3907700 | 150692 | None | SBM-62 | Supplying And fixing/replacing of 6/16/32A electricalaccessories on existing switch board 32 A Bakelite DP | Each | 232.0 | 232.0 | 6.0 | False | None | None | False | None | False | 1392.0 | 0 |
3907701 | 150692 | None | SBM-63 | Supplying, fixing, wiring, earth electrode for grounding conduits, I.C.cutout sand other equipment's on the meter board using 40mm dia 2.90 mm thick GI pipe 2.5 m long buried in a pit. The pit should be filled with equal proportion of salt and char coal 150 mm all-round the pipe to completed epth. The connection from the pipe to the conduit etc., is to be established through GI wire of size as per lSI specification 7.3.3. of IS 732 using 12 mm dia bolts, nuts, washer sand check nuts etc., the pipe shall have 16 through holes of 12 mm dia | Each | 3510.0 | 3510.0 | 2.0 | False | None | None | False | None | False | 7020.0 | 0 |
3907702 | 150692 | None | SBM-64 | Supply of LED flood light luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of antiglare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light output Rated life Burning Hrs 50000hr @Lumen Maintenance of 70%, CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection - Min 5KV along with Over voltageOverload LED Floodlight 100W. | Each | 9486.0 | 9486.0 | 2.0 | False | None | None | False | None | False | 18972.0 | 0 |