createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1725519580842
version3
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd965000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose05-10-2024 16:00:00
tenderQueryClose20-09-2024 16:00:00
technicalBidOpen07-10-2024 16:00:00
publishedDate05-09-2024 19:45:22
publishedByPostKHB_EE_CO_BNG
publishedByUserKPE11677 - SHIVASHANKARAPPA K H
bidValidityPeriod180
noOfCalls1
preBidMeetingDate21-09-2024 16:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonSHIVASHANKARAPPA K H
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08022273511
mobileNumber8022273511
tenderSupplierListNone
tenderSchedule
createdTs1725519580862
version4
createdDateNone
modifiedDateNone
tenderNumberKHB/2024-25/BD/WORK_INDENT268
titleConstruction of Hostel Building (G Plus 4) at Minority Welfare Department-Government Muslim Residential School at Srirangapattana Town, Srirangapattana Taluk, Mandya District
descriptionConstruction of Hostel Building (G Plus 4) at Minority Welfare Department-Government Muslim Residential School at Srirangapattana Town, Srirangapattana Taluk, Mandya District
categoryWORKS
categoryTextWorks
ecv64099329.63
deptNameKarnataka Housing Board
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location5488
locationNameKHB Central Office Bengaluru
provisionalAmount64099330.0
groupOverheadTotalNone
fileNumberKHB/CE/AE-1/MWD/323/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17255195810000NoneNoneBuildingsConstruction of Hostel Building (G Plus 4) at Minority Welfare Department-Government Muslim Residential School at Srirangapattana Town, Srirangapattana Taluk, Mandya District64099329.63
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3926204151422Nonecode01Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. - In all kinds of soils upto 300 mm depthCum97.8597.85276.0FalseNoneNoneFalseNoneFalse27006.60
3926205151422Nonecode02Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work - In all kinds of soils - Depth upto 3 mCum105.06105.061204.82FalseNoneNoneFalseNoneFalse126578.38920
3926206151422Nonecode03Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work- n all kinds of soils - In ordinary/soft rock without blasting upto 1.5 m depthCum373.89373.89225.21FalseNoneNoneFalseNoneFalse84203.76690
3926207151422Nonecode04Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. - In all kinds of soils Depth upto 1.5 mCum249.26249.26112.6FalseNoneNoneFalseNoneFalse28066.6760
3926208151422Nonecode05Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications.Sqm121.54121.54941.08FalseNoneNoneFalseNoneFalse114378.86320
3926209151422Nonecode06Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregatesCum5833.925833.9295.7498FalseNoneNoneFalseNoneFalse558596.6732160
3926210151422Nonecode07Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. - Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregatesCum6168.676168.6797.83FalseNoneNoneFalseNoneFalse603480.98610
3926211151422Nonecode08Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. - For FOOTINGSCum6526.086526.08229.68FalseNoneNoneFalseNoneFalse1498910.05440
3926212151422Nonecode09Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) -M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For PEDESTALCum6526.086526.0833.27FalseNoneNoneFalseNoneFalse217122.68160
3926213151422Nonecode10Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Columns, Plinth Beam, Roof Beam, Roof Slab, Staircase, Lintel, Cill and Chejja - GROUND FLOORCum7048.297048.29340.16FalseNoneNoneFalseNoneFalse2397546.32640
3926214151422Nonecode11Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Columns, Plinth Beam, Roof Beam, Roof Slab, Staircase, Lintel, Cill and Chejja - FIRST FLOORCum7118.777118.77239.51FalseNoneNoneFalseNoneFalse1705016.60270
3926215151422Nonecode12Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Columns, Plinth Beam, Roof Beam, Roof Slab, Staircase, Lintel, Cill and Chejja - SECOND FLOORCum7189.267189.26239.67FalseNoneNoneFalseNoneFalse1723049.94420
3926216151422Nonecode13Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Columns, Plinth Beam, Roof Beam, Roof Slab, Staircase, Lintel, Cill and Chejja - THIRD FLOORCum7259.747259.74238.01FalseNoneNoneFalseNoneFalse1727890.71740
3926217151422Nonecode14Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Columns, Roof Beam, Roof Slab, Staircase, Lintel, Cill and Chejja - FOURTH FLOORCum7330.227330.22238.01FalseNoneNoneFalseNoneFalse1744665.66220
3926218151422Nonecode15Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) - M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - For Columns, Roof Beam, Roof Slab, Staircase, Lintel, Cill and Chejja - TERRACE FLOORCum7400.77400.747.69FalseNoneNoneFalseNoneFalse352939.3830
3926219151422Nonecode16Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings - GROUND FLOORTonne92140.7192140.7153.54FalseNoneNoneFalseNoneFalse4933213.61340
3926220151422Nonecode17Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings - FIRST FLOORTonne93062.1293062.1216.89FalseNoneNoneFalseNoneFalse1571819.20680
3926221151422Nonecode18Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings - SECOND FLOORTonne93983.5293983.5216.79FalseNoneNoneFalseNoneFalse1577983.30080
3926222151422Nonecode19Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings - THIRD FLOORTonne94904.9394904.9316.79FalseNoneNoneFalseNoneFalse1593453.77470
3926223151422Nonecode20Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings - FOURTH FLOORTonne95826.3495826.3416.79FalseNoneNoneFalseNoneFalse1608924.24860
3926224151422Nonecode21Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings - TERRACE FLOORTonne96747.7596747.753.89FalseNoneNoneFalseNoneFalse376348.74750
3926225151422Nonecode22Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum273.98273.98813.84FalseNoneNoneFalseNoneFalse222975.88320
3926226151422Nonecode23Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum445.99445.99250.56FalseNoneNoneFalseNoneFalse111747.25440
3926227151422Nonecode24Loading and Unloading of Stone Boulder /Stone aggregates /Sand /Kankar /Moorum. (Tipper 14 m3) - Taking output 10 t load and lead 10 km = 100 kmCum108.36108.36312.19FalseNoneNoneFalseNoneFalse33828.90840
3926228151422Nonecode25Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - GROUND FLOORSqm1349.31349.3304.54FalseNoneNoneFalseNoneFalse410915.8220
3926229151422Nonecode26Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - FIRST FLOORSqm1362.791362.79326.67FalseNoneNoneFalseNoneFalse445182.60930
3926230151422Nonecode27Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - SECOND FLOORSqm1376.291376.29326.67FalseNoneNoneFalseNoneFalse449592.65430
3926231151422Nonecode28Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - THIRD FLOORSqm1389.781389.78326.67FalseNoneNoneFalseNoneFalse453999.43260
3926232151422Nonecode29Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - FOURTH FLOORSqm1403.271403.27326.67FalseNoneNoneFalseNoneFalse458406.21090
3926233151422Nonecode30Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - TERRACE FLOORSqm1416.771416.77209.44FalseNoneNoneFalseNoneFalse296728.30880
3926234151422Nonecode31Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - GROUND FLOORSqm1267.931267.93278.45FalseNoneNoneFalseNoneFalse353055.10850
3926235151422Nonecode32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - FIRST FLOORSqm1280.611280.61261.95FalseNoneNoneFalseNoneFalse335455.78950
3926236151422Nonecode33Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - SECOND FLOORCum1293.291293.29261.95FalseNoneNoneFalseNoneFalse338777.31550
3926237151422Nonecode34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - THIRD FLOORSqm1305.971305.97261.95FalseNoneNoneFalseNoneFalse342098.84150
3926238151422Nonecode35Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - FOURTH FLOORSqm1318.651318.65261.95FalseNoneNoneFalseNoneFalse345420.36750
3926239151422Nonecode36Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - GROUND FLOORSqm1137.121137.129.27FalseNoneNoneFalseNoneFalse10541.10240
3926240151422Nonecode37Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - FIRST FLOORSqm1148.491148.49112.63FalseNoneNoneFalseNoneFalse129354.42870
3926241151422Nonecode38Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - SECOND FLOORCum1159.861159.86112.63FalseNoneNoneFalseNoneFalse130635.03180
3926242151422Nonecode39Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - THIRD FLOORSqm1171.231171.23112.63FalseNoneNoneFalseNoneFalse131915.63490
3926243151422Nonecode40Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. - FOURTH FLOORSqm1182.61182.6112.63FalseNoneNoneFalseNoneFalse133196.2380
3926244151422Nonecode41Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling Plastering - GROUND FLOORSqm262.65262.65644.01FalseNoneNoneFalseNoneFalse169149.22650
3926245151422Nonecode42Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling Plastering - FIRST FLOORSqm265.28265.28465.09FalseNoneNoneFalseNoneFalse123379.07520
3926246151422Nonecode43Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling Plastering - SECOND FLOORSqm267.9267.9465.09FalseNoneNoneFalseNoneFalse124597.6110
3926247151422Nonecode44Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling Plastering - THIRD FLOORSqm270.53270.53465.09FalseNoneNoneFalseNoneFalse125820.79770
3926248151422Nonecode45Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling Plastering - FOURTH FLOORSqm273.16273.16465.09FalseNoneNoneFalseNoneFalse127043.98440
3926249151422Nonecode46Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ceiling Plastering - TERRACE FLOORSqm275.78275.7821.68FalseNoneNoneFalseNoneFalse5978.91040
3926250151422Nonecode47Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal Wall Plastering - GROUND FLOORSqm359.47359.471209.37FalseNoneNoneFalseNoneFalse434732.23390
3926251151422Nonecode48Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal Wall Plastering - FIRST FLOORSqm363.06363.061583.05FalseNoneNoneFalseNoneFalse574742.1330
3926252151422Nonecode49Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal Wall Plastering - SECOND FLOORSqm366.66366.661583.05FalseNoneNoneFalseNoneFalse580441.1130
3926253151422Nonecode50Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal Wall Plastering - THIRD FLOORSqm370.25370.251583.05FalseNoneNoneFalseNoneFalse586124.26250
3926254151422Nonecode51Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal Wall Plastering - FOURTH FLOORSqm373.85373.851583.05FalseNoneNoneFalseNoneFalse591823.24250
3926255151422Nonecode52Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Internal Wall Plastering - TERRACE FLOORSqm377.44377.4478.96FalseNoneNoneFalseNoneFalse29802.66240
3926256151422Nonecode53Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Wall Plastering - GROUND FLOORSqm382.13382.13722.84FalseNoneNoneFalseNoneFalse276218.84920
3926257151422Nonecode54Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Wall Plastering - FIRST FLOORSqm385.95385.95476.89FalseNoneNoneFalseNoneFalse184055.69550
3926258151422Nonecode55Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Wall Plastering - SECOND FLOORSqm389.77389.77476.89FalseNoneNoneFalseNoneFalse185877.41530
3926259151422Nonecode56Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Wall Plastering - THIRD FLOORSqm393.59393.59476.89FalseNoneNoneFalseNoneFalse187699.13510
3926260151422Nonecode57Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Wall Plastering - FOURTH FLOORSqm397.42397.42476.89FalseNoneNoneFalseNoneFalse189525.62380
3926261151422Nonecode58Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. External Wall Plastering - TERRACE FLOORSqm401.24401.24377.17FalseNoneNoneFalseNoneFalse151335.69080
3926262151422Nonecode59KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C. chajja with plastering ( labour charges only ) as per specifications. Specification No. KBS - GROUND FLOORm33.9933.9974.4FalseNoneNoneFalseNoneFalse2528.8560
3926263151422Nonecode60KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C. chajja with plastering ( labour charges only ) as per specifications. Specification No. KBS - FIRST FLOORm34.3334.3387.4FalseNoneNoneFalseNoneFalse3000.4420
3926264151422Nonecode61KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C. chajja with plastering ( labour charges only ) as per specifications. Specification No. KBS - SECOND FLOORm34.6734.6787.4FalseNoneNoneFalseNoneFalse3030.1580
3926265151422Nonecode62KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C. chajja with plastering ( labour charges only ) as per specifications. Specification No. KBS - THIRD FLOORm35.0135.0187.4FalseNoneNoneFalseNoneFalse3059.8740
3926266151422Nonecode63KSRB 4-2.12 : Extra for providing throating or drip moulding to R.C.C. chajja with plastering ( labour charges only ) as per specifications. Specification No. KBS - FOURTH FLOORm35.3535.3587.4FalseNoneNoneFalseNoneFalse3089.590
3926267151422Nonecode64KSRB 15.8 : Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment ) - KSRB 15.8.1 do suitable plaster mesh 100mm wide - GROUND FLOORm26.7826.78850.0FalseNoneNoneFalseNoneFalse22763.00
3926268151422Nonecode65KSRB 15.8 : Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment ) - KSRB 15.8.1 do suitable plaster mesh 100mm wide - FIRST FLOORm27.0527.051300.0FalseNoneNoneFalseNoneFalse35165.00
3926269151422Nonecode66KSRB 15.8 : Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment ) - KSRB 15.8.1 do suitable plaster mesh 100mm wide- SECOND FLOORm27.3227.321300.0FalseNoneNoneFalseNoneFalse35516.00
3926270151422Nonecode67KSRB 15.8 : Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment ) - KSRB 15.8.1 do suitable plaster mesh 100mm wide - THIRD FLOORm27.5827.581300.0FalseNoneNoneFalseNoneFalse35854.00
3926271151422Nonecode68KSRB 15.8 : Providing and fixing suitable plaster mesh manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment ) - KSRB 15.8.1 do suitable plaster mesh 100mm wide - FOURTH FLOORm27.8527.851300.0FalseNoneNoneFalseNoneFalse36205.00
3926272151422Nonecode69Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.- Size of Tile 600x600 mm - GROUND FLOORSqm1179.351179.3581.53FalseNoneNoneFalseNoneFalse96152.40550
3926273151422Nonecode70Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.- Size of Tile 600x600 mm - FIRST FLOORSqm1191.141191.14321.8FalseNoneNoneFalseNoneFalse383308.8520
3926274151422Nonecode71Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.- Size of Tile 600x600 mm - SECOND FLOORSqm1202.941202.94321.8FalseNoneNoneFalseNoneFalse387106.0920
3926275151422Nonecode72Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.- Size of Tile 600x600 mm - THIRD FLOORSqm1214.731214.73321.8FalseNoneNoneFalseNoneFalse390900.1140
3926276151422Nonecode73Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.- Size of Tile 600x600 mm - FOURTH FLOORSqm1226.521226.52321.8FalseNoneNoneFalseNoneFalse394694.1360
3926277151422Nonecode74Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. - GROUND FLOORSqm2147.552147.55460.23FalseNoneNoneFalseNoneFalse988366.93650
3926278151422Nonecode75Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. - FIRST FLOORSqm2169.032169.0394.86FalseNoneNoneFalseNoneFalse205754.18580
3926279151422Nonecode76Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. - SECOND FLOORSqm2190.52190.594.86FalseNoneNoneFalseNoneFalse207790.830
3926280151422Nonecode77Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. - THIRD FLOORSqm2211.982211.9894.86FalseNoneNoneFalseNoneFalse209828.42280
3926281151422Nonecode78Providing and laying Polished Sadarahalli Grey Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 20 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. - FOURTH FLOORSqm2233.452233.4594.86FalseNoneNoneFalseNoneFalse211865.0670
3926282151422Nonecode79Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. - GROUND FLOORSqm5487.845487.8434.23FalseNoneNoneFalseNoneFalse187848.76320
3926283151422Nonecode80Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. - FIRST FLOORSqm5542.725542.7223.39FalseNoneNoneFalseNoneFalse129644.22080
3926284151422Nonecode81Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. - SECOND FLOORSqm5597.65597.623.39FalseNoneNoneFalseNoneFalse130927.8640
3926285151422Nonecode82Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. - THIRD FLOORSqm5652.485652.4823.39FalseNoneNoneFalseNoneFalse132211.50720
3926286151422Nonecode83Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications. - FOURTH FLOORSqm5707.355707.3523.39FalseNoneNoneFalseNoneFalse133494.91650
3926287151422Nonecode84Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. - GROUND FLOORSqm915.67915.677.91FalseNoneNoneFalseNoneFalse7242.94970
3926288151422Nonecode85Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. - FIRST FLOORSqm924.83924.8374.51FalseNoneNoneFalseNoneFalse68909.08330
3926289151422Nonecode86Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. - SECOND FLOORSqm933.98933.9874.51FalseNoneNoneFalseNoneFalse69590.84980
3926290151422Nonecode87Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. - THIRD FLOORSqm943.14943.1474.51FalseNoneNoneFalseNoneFalse70273.36140
3926291151422Nonecode88Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. - FOURTH FLOORSqm952.3952.374.51FalseNoneNoneFalseNoneFalse70955.8730
3926292151422Nonecode89Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. - GROUND FLOORSqm1492.471492.4759.33FalseNoneNoneFalseNoneFalse88548.24510
3926293151422Nonecode90Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. - FIRST FLOORSqm1507.391507.39204.11FalseNoneNoneFalseNoneFalse307673.37290
3926294151422Nonecode91Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. - SECOND FLOORSqm1522.321522.32204.11FalseNoneNoneFalseNoneFalse310720.73520
3926295151422Nonecode92Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. - THIRD FLOORSqm1537.241537.24204.11FalseNoneNoneFalseNoneFalse313766.05640
3926296151422Nonecode93Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. - FOURTH FLOORSqm1552.171552.17204.11FalseNoneNoneFalseNoneFalse316813.41870
3926297151422Nonecode94Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. - GROUND FLOORCum102588.0102588.05.37FalseNoneNoneFalseNoneFalse550897.560
3926298151422Nonecode95Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. - FIRST FLOORCum103613.88103613.880.89FalseNoneNoneFalseNoneFalse92216.35320
3926299151422Nonecode96Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. - SECOND FLOORCum104639.76104639.760.89FalseNoneNoneFalseNoneFalse93129.38640
3926300151422Nonecode97Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. - THIRD FLOORCum105665.64105665.640.89FalseNoneNoneFalseNoneFalse94042.41960
3926301151422Nonecode98Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. - FOURTH FLOORCum106691.52106691.520.89FalseNoneNoneFalseNoneFalse94955.45280
3926302151422Nonecode99Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. - TERRACE FLOORCum107717.4107717.40.08FalseNoneNoneFalseNoneFalse8617.3920
3926303151422Nonecode100Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. - GROUND FLOORNo1046.481046.4810.0FalseNoneNoneFalseNoneFalse10464.80
3926304151422Nonecode101Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. - FIRST FLOORNo1056.941056.9413.0FalseNoneNoneFalseNoneFalse13740.220
3926305151422Nonecode102Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. - SECOND FLOORNo1067.411067.4113.0FalseNoneNoneFalseNoneFalse13876.330
3926306151422Nonecode103Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. - THIRD FLOORNo1077.871077.8713.0FalseNoneNoneFalseNoneFalse14012.310
3926307151422Nonecode104Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. - FOURTH FLOORNo1088.341088.3413.0FalseNoneNoneFalseNoneFalse14148.420
3926308151422Nonecode105Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. - TERRACE FLOORNo1098.81098.81.0FalseNoneNoneFalseNoneFalse1098.80
3926309151422Nonecode106Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick both side commercial - GROUND FLOORSqm3095.153095.1519.68FalseNoneNoneFalseNoneFalse60912.5520
3926310151422Nonecode107Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick both side commercial - FIRST FLOORSqm3126.13126.127.3FalseNoneNoneFalseNoneFalse85342.530
3926311151422Nonecode108Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick both side commercial - SECOND FLOORSqm3157.053157.0527.3FalseNoneNoneFalseNoneFalse86187.4650
3926312151422Nonecode109Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick both side commercial - THIRD FLOORSqm3188.03188.027.3FalseNoneNoneFalseNoneFalse87032.40
3926313151422Nonecode110Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick both side commercial - FOURTH FLOORSqm3218.963218.9627.3FalseNoneNoneFalseNoneFalse87877.6080
3926314151422Nonecode111Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 30 mm thick both side commercial - TERRACE FLOORSqm3249.913249.912.52FalseNoneNoneFalseNoneFalse8189.77320
3926315151422Nonecode112Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )Sqm7667.327667.3212.24FalseNoneNoneFalseNoneFalse93847.99680
3926316151422Nonecode113Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately). - Size 62 x 125mm - GROUND FLOORm786.92786.929.9FalseNoneNoneFalseNoneFalse7790.5080
3926317151422Nonecode114Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately). - Size 62 x 125mm - FIRST FLOORm794.79794.7999.0FalseNoneNoneFalseNoneFalse78684.210
3926318151422Nonecode115Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately). - Size 62 x 125mm - SECOND FLOORm802.66802.6699.0FalseNoneNoneFalseNoneFalse79463.340
3926319151422Nonecode116Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately). - Size 62 x 125mm - THIRD FLOORm810.53810.5399.0FalseNoneNoneFalseNoneFalse80242.470
3926320151422Nonecode117Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately). - Size 62 x 125mm - FOURTH FLOORm818.4818.499.0FalseNoneNoneFalseNoneFalse81021.60
3926321151422Nonecode118Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately). 30 mm thickness - GROUND FLOORSqm3589.553589.553.15FalseNoneNoneFalseNoneFalse11307.08250
3926322151422Nonecode119Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately). 30 mm thickness - FIRST FLOORSqm3625.453625.4531.5FalseNoneNoneFalseNoneFalse114201.6750
3926323151422Nonecode120Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately). 30 mm thickness - SECOND FLOORSqm3661.343661.3431.5FalseNoneNoneFalseNoneFalse115332.210
3926324151422Nonecode121Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately). 30 mm thickness - THIRD FLOORSqm3697.243697.2431.5FalseNoneNoneFalseNoneFalse116463.060
3926325151422Nonecode122Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges.(Cost of Fixtures to be paid separately). 30 mm thickness - FOURTH FLOORSqm3733.133733.1331.5FalseNoneNoneFalseNoneFalse117593.5950
3926326151422Nonecode123Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - GROUND FLOORSqm6936.026936.0244.78FalseNoneNoneFalseNoneFalse310594.97560
3926327151422Nonecode124Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - FIRST FLOORSqm7005.387005.3832.63FalseNoneNoneFalseNoneFalse228585.54940
3926328151422Nonecode125Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - SECOND FLOORSqm7074.747074.7432.63FalseNoneNoneFalseNoneFalse230848.76620
3926329151422Nonecode126Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - THIRD FLOORSqm7144.17144.132.63FalseNoneNoneFalseNoneFalse233111.9830
3926330151422Nonecode127Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - FOURTH FLOORSqm7213.467213.4632.63FalseNoneNoneFalseNoneFalse235375.19980
3926331151422Nonecode128Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - GROUND FLOORSqm5890.575890.572.64FalseNoneNoneFalseNoneFalse15551.10480
3926332151422Nonecode129Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - FIRST FLOORSqm5949.485949.4827.42FalseNoneNoneFalseNoneFalse163134.74160
3926333151422Nonecode130Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - SECOND FLOORSqm6008.386008.3827.42FalseNoneNoneFalseNoneFalse164749.77960
3926334151422Nonecode131Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - THIRD FLOORSqm6067.296067.2927.42FalseNoneNoneFalseNoneFalse166365.09180
3926335151422Nonecode132Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) - FOURTH FLOORSqm6126.196126.1927.42FalseNoneNoneFalseNoneFalse167980.12980
3926336151422Nonecode133Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. - GROUND FLOORNo1083.561083.5610.0FalseNoneNoneFalseNoneFalse10835.60
3926337151422Nonecode134Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. -FIRST FLOORNo1094.41094.413.0FalseNoneNoneFalseNoneFalse14227.20
3926338151422Nonecode135Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. - SECOND FLOORNo1105.231105.2313.0FalseNoneNoneFalseNoneFalse14367.990
3926339151422Nonecode136Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. -THIRD FLOORNo1116.071116.0713.0FalseNoneNoneFalseNoneFalse14508.910
3926340151422Nonecode137Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. - FOURTH FLOORNo1126.91126.913.0FalseNoneNoneFalseNoneFalse14649.70
3926341151422Nonecode138Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm - GROUND FLOOREach448.05448.0520.0FalseNoneNoneFalseNoneFalse8961.00
3926342151422Nonecode139Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm - FIRST FLOOREach452.53452.5326.0FalseNoneNoneFalseNoneFalse11765.780
3926343151422Nonecode140Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm - SECOND FLOOREach457.01457.0126.0FalseNoneNoneFalseNoneFalse11882.260
3926344151422Nonecode141Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm - THIRD FLOOREach461.49461.4926.0FalseNoneNoneFalseNoneFalse11998.740
3926345151422Nonecode142Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete : 250x10mm - FOURTH FLOOREach465.97465.9726.0FalseNoneNoneFalseNoneFalse12115.220
3926346151422Nonecode143Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete - GROUND FLOOREach243.08243.0810.0FalseNoneNoneFalseNoneFalse2430.80
3926347151422Nonecode144Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete - FIRST FLOOREach245.51245.5113.0FalseNoneNoneFalseNoneFalse3191.630
3926348151422Nonecode145Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete - SECOND FLOOREach247.94247.9413.0FalseNoneNoneFalseNoneFalse3223.220
3926349151422Nonecode146Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete - THIRD FLOOREach250.37250.3713.0FalseNoneNoneFalseNoneFalse3254.810
3926350151422Nonecode147Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete - FOURTH FLOOREach252.8252.813.0FalseNoneNoneFalseNoneFalse3286.40
3926351151422Nonecode148Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125 mm with plate 175x32 mm - GROUND FLOOREach256.47256.4720.0FalseNoneNoneFalseNoneFalse5129.40
3926352151422Nonecode149Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125 mm with plate 175x32 mm -FIRST FLOOREach259.03259.0326.0FalseNoneNoneFalseNoneFalse6734.780
3926353151422Nonecode150Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125 mm with plate 175x32 mm - SECOND FLOOREach261.6261.626.0FalseNoneNoneFalseNoneFalse6801.60
3926354151422Nonecode151Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125 mm with plate 175x32 mm -THIRD FLOOREach264.16264.1626.0FalseNoneNoneFalseNoneFalse6868.160
3926355151422Nonecode152Providing and fixing bright finished brass handles with screws etc. complete: Brass handles 125 mm with plate 175x32 mm - FOURTH FLOOREach266.73266.7326.0FalseNoneNoneFalseNoneFalse6934.980
3926356151422Nonecode153Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) - GROUND FLOORNo283.25283.2540.0FalseNoneNoneFalseNoneFalse11330.00
3926357151422Nonecode154Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) - FIRST FLOORNo286.08286.08156.0FalseNoneNoneFalseNoneFalse44628.480
3926358151422Nonecode155Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) - SECOND FLOORNo288.92288.92156.0FalseNoneNoneFalseNoneFalse45071.520
3926359151422Nonecode156Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) - THIRD FLOORNo291.75291.75156.0FalseNoneNoneFalseNoneFalse45513.00
3926360151422Nonecode157Providing and fixing bright finished brass butt hinges with necessary screws etc. complete : 125x85x5.5 mm (heavy type) - FOURTH FLOORNo294.58294.58156.0FalseNoneNoneFalseNoneFalse45954.480
3926361151422Nonecode158Teak wood beading - GROUND FLOORm61.861.846.8FalseNoneNoneFalseNoneFalse2892.240
3926362151422Nonecode159Teak wood beading - FIRST FLOORm62.4262.4267.6FalseNoneNoneFalseNoneFalse4219.5920
3926363151422Nonecode160Teak wood beading - SECOND FLOORm63.0463.0467.6FalseNoneNoneFalseNoneFalse4261.5040
3926364151422Nonecode161Teak wood beading - THIRD FLOORm63.6563.6567.6FalseNoneNoneFalseNoneFalse4302.740
3926365151422Nonecode162Teak wood beading - FOURTH FLOORm64.2764.2767.6FalseNoneNoneFalseNoneFalse4344.6520
3926366151422Nonecode163Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. - GROUND FLOORKgs188.49188.49853.47FalseNoneNoneFalseNoneFalse160870.56030
3926367151422Nonecode164Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. - FIRST FLOORKgs190.37190.371240.65FalseNoneNoneFalseNoneFalse236182.54050
3926368151422Nonecode165Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. - SECOND FLOORKgs192.26192.261240.65FalseNoneNoneFalseNoneFalse238527.3690
3926369151422Nonecode166Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. - THIRD FLOORKgs194.14194.141240.65FalseNoneNoneFalseNoneFalse240859.7910
3926370151422Nonecode167Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. - FOURTH FLOORKgs196.03196.031240.65FalseNoneNoneFalseNoneFalse243204.61950
3926371151422Nonecode168Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. - TERRACE FLOORKgs197.99197.9922.5FalseNoneNoneFalseNoneFalse4454.7750
3926372151422Nonecode169Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. - GROUND FLOORKgs581.95581.95249.2FalseNoneNoneFalseNoneFalse145021.940
3926373151422Nonecode170Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. - FIRST FLOORKgs587.77587.77101.58FalseNoneNoneFalseNoneFalse59705.67660
3926374151422Nonecode171Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. - SECOND FLOORKgs593.59593.59101.58FalseNoneNoneFalseNoneFalse60296.87220
3926375151422Nonecode172Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. - THIRD FLOORKgs599.41599.41101.58FalseNoneNoneFalseNoneFalse60888.06780
3926376151422Nonecode173Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. - FOURTH FLOORKgs605.23605.23101.58FalseNoneNoneFalseNoneFalse61479.26340
3926377151422Nonecode174Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. - GROUND FLOORSqm287.37287.3731.08FalseNoneNoneFalseNoneFalse8931.45960
3926378151422Nonecode175Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. - FIRST FLOORSqm290.24290.24213.78FalseNoneNoneFalseNoneFalse62047.50720
3926379151422Nonecode176Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. - SECOND FLOORSqm293.12293.12213.78FalseNoneNoneFalseNoneFalse62663.19360
3926380151422Nonecode177Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. - THIRD FLOORSqm295.99295.99213.78FalseNoneNoneFalseNoneFalse63276.74220
3926381151422Nonecode178Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.- FOURTH FLOORSqm298.86298.86213.78FalseNoneNoneFalseNoneFalse63890.29080
3926382151422Nonecode179Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. - GROUND FLOORSqm103.0103.01853.39FalseNoneNoneFalseNoneFalse190899.170
3926383151422Nonecode180Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. - FIRST FLOORSqm104.03104.032048.14FalseNoneNoneFalseNoneFalse213068.00420
3926384151422Nonecode181Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. - SECOND FLOORSqm105.06105.062048.14FalseNoneNoneFalseNoneFalse215177.58840
3926385151422Nonecode182Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. - THIRD FLOORSqm106.09106.092048.14FalseNoneNoneFalseNoneFalse217287.17260
3926386151422Nonecode183Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. - FOURTH FLOORSqm107.12107.122048.14FalseNoneNoneFalseNoneFalse219396.75680
3926387151422Nonecode184Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. - TERRACE FLOORSqm108.15108.15100.64FalseNoneNoneFalseNoneFalse10884.2160
3926388151422Nonecode185Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - GROUND FLOORSqm185.4185.41853.39FalseNoneNoneFalseNoneFalse343618.5060
3926389151422Nonecode186Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - FIRST FLOORSqm187.25187.252048.14FalseNoneNoneFalseNoneFalse383514.2150
3926390151422Nonecode187Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. -SECOND FLOORSqm189.11189.112048.14FalseNoneNoneFalseNoneFalse387323.75540
3926391151422Nonecode188Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. -THIRD FLOORSqm190.96190.962048.14FalseNoneNoneFalseNoneFalse391112.81440
3926392151422Nonecode189Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - FOURTH FLOORSqm192.82192.822048.14FalseNoneNoneFalseNoneFalse394922.35480
3926393151422Nonecode190Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge. - Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. -TERRACE FLOORSqm194.67194.67100.64FalseNoneNoneFalseNoneFalse19591.58880
3926394151422Nonecode191Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - GROUND FLOORSqm183.34183.34677.52FalseNoneNoneFalseNoneFalse124216.51680
3926395151422Nonecode192Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - FIRST FLOORSqm185.17185.17476.89FalseNoneNoneFalseNoneFalse88305.72130
3926396151422Nonecode193Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - SECOND FLOORSqm187.01187.01476.89FalseNoneNoneFalseNoneFalse89183.19890
3926397151422Nonecode194Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - THIRD FLOORSqm188.84188.84476.89FalseNoneNoneFalseNoneFalse90055.90760
3926398151422Nonecode195Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - FOURTH FLOORSqm190.67190.67476.89FalseNoneNoneFalseNoneFalse90928.61630
3926399151422Nonecode196Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives with pure Acrylic Resin, UV resistant, dirt & pick up resistant, Alkali & Water resistant of required shade: New work (Two coats applied @ 1.43 L/10 Sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 Sqm) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - TERRACE FLOORSqm192.51192.51377.17FalseNoneNoneFalseNoneFalse72608.99670
3926400151422Nonecode197Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - GROUND FLOORSqm172.01172.01196.95FalseNoneNoneFalseNoneFalse33877.36950
3926401151422Nonecode198Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - FIRST FLOORSqm173.73173.73137.75FalseNoneNoneFalseNoneFalse23931.30750
3926402151422Nonecode199Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. -SECOND FLOORSqm175.45175.45137.75FalseNoneNoneFalseNoneFalse24168.23750
3926403151422Nonecode200Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.. -THIRD FLOORSqm177.17177.17137.75FalseNoneNoneFalseNoneFalse24405.16750
3926404151422Nonecode201Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. - FOURTH FLOORSqm178.89178.89137.75FalseNoneNoneFalseNoneFalse24642.09750
3926405151422Nonecode202Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. -TERRACE FLOORSqm180.61180.617.3FalseNoneNoneFalseNoneFalse1318.4530
3926406151422Nonecode203Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. - GROUND FLOORCum6475.616475.611.78FalseNoneNoneFalseNoneFalse11526.58580
3926407151422Nonecode204Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. - FIRST FLOORCum6540.376540.377.89FalseNoneNoneFalseNoneFalse51603.51930
3926408151422Nonecode205Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. - SECOND FLOORCum6605.126605.127.89FalseNoneNoneFalseNoneFalse52114.39680
3926409151422Nonecode206Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. - THIRD FLOORCum6669.886669.887.89FalseNoneNoneFalseNoneFalse52625.35320
3926410151422Nonecode207Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. - FOURTH FLOORCum6734.636734.637.89FalseNoneNoneFalseNoneFalse53136.23070
3926411151422Nonecode208Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. - M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. - TERRACE FLOORCum6799.396799.3942.19FalseNoneNoneFalseNoneFalse286866.26410
3926412151422Nonecode209Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. - FIRST FLOORCum2098.292098.2923.66FalseNoneNoneFalseNoneFalse49645.54140
3926413151422Nonecode210Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. - SECOND FLOORCum2119.062119.0623.66FalseNoneNoneFalseNoneFalse50136.95960
3926414151422Nonecode211Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. - THIRD FLOORCum2139.842139.8423.66FalseNoneNoneFalseNoneFalse50628.61440
3926415151422Nonecode212Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. - FOURTH FLOORCum2160.612160.6123.66FalseNoneNoneFalseNoneFalse51120.03260
3926416151422Nonecode213Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. - TERRACE FLOORCum2181.392181.393.02FalseNoneNoneFalseNoneFalse6587.79780
3926417151422Nonecode214Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. - FIRST FLOORSqm849.93849.93134.85FalseNoneNoneFalseNoneFalse114613.06050
3926418151422Nonecode215Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. - SECOND FLOORSqm858.34858.34134.85FalseNoneNoneFalseNoneFalse115747.1490
3926419151422Nonecode216Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. - THIRD FLOORSqm866.76866.76134.85FalseNoneNoneFalseNoneFalse116882.5860
3926420151422Nonecode217Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. - FOURTH FLOORSqm875.17875.17134.85FalseNoneNoneFalseNoneFalse118016.67450
3926421151422Nonecode218Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. - TERRACE FLOORSqm883.59883.59551.93FalseNoneNoneFalseNoneFalse487679.82870
3926422151422Nonecode219Providing & applying high strength non shrink free flow grout (confirming to BS 1881-Part 116 : 1983)comprising of blend of portland cement, graded fillars and chemical additives which impart controlled expansion in the plastic state duly minimizing water demand. (Minimum 25mm thickness around the pipe)No252.35252.35125.0FalseNoneNoneFalseNoneFalse31543.750
3926423151422Nonecode220Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. - GROUND FLOORSqm4612.344612.341.5FalseNoneNoneFalseNoneFalse6918.510
3926424151422Nonecode221Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. - FIRST FLOORSqm4658.464658.461.5FalseNoneNoneFalseNoneFalse6987.690
3926425151422Nonecode222Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. - SECOND FLOORSqm4704.594704.591.5FalseNoneNoneFalseNoneFalse7056.8850
3926426151422Nonecode223Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. - THIRD FLOORSqm4750.714750.711.5FalseNoneNoneFalseNoneFalse7126.0650
3926427151422Nonecode224Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge. - FOURTH FLOORSqm4796.834796.831.5FalseNoneNoneFalseNoneFalse7195.2450
3926428151422Nonecode225Providing and laying Cement concrete flooring 40 mm thick with 20 mm nominal size stone aggregate using 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry complete.Sqm464.53464.53199.5FalseNoneNoneFalseNoneFalse92673.7350
3926429151422Nonecode226Providing and laying flooring with burnt stone slabs 10 cms thick rough chistle dressed on cement mortar bed 1:6, 25 mm thick, and pointed with cement mortar 1:3, , including cost of materials, mortar, labour, curing complete as per specifications.Sqm2459.642459.644.8FalseNoneNoneFalseNoneFalse11806.2720
3926430151422Nonecode227Providing and laying 60mm thick factory made cement concrete paver block of approved shape and colour of M -30 grade made of C&D waste by block making machine with vibratory compaction laid in required pattern and including over 50mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge.Sqm824.0824.0849.77FalseNoneNoneFalseNoneFalse700210.480
3926431151422Nonecode228Construction of Granular Sub-Base of required grading as per design spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with front end loader at OMC and compacting with vibratory roller to achieve the desired density, complete as per clause 401, For Grading -V MaterialCum2429.772429.77169.95FalseNoneNoneFalseNoneFalse412939.41150
3926432151422Nonecode229Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. - 20 mm nominal dia pipesm390.37390.37256.25FalseNoneNoneFalseNoneFalse100032.31250
3926433151422Nonecode230Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. - 25 mm nominal dia pipesm491.31491.31105.2FalseNoneNoneFalseNoneFalse51685.8120
3926434151422Nonecode231Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. - 32 mm nominal dia pipesm573.71573.7148.0FalseNoneNoneFalseNoneFalse27538.080
3926435151422Nonecode232Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for: Pipes of SN 4, 75mm dia.m223.51223.51327.0FalseNoneNoneFalseNoneFalse73087.770
3926436151422Nonecode233Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for: Pipes of SN 4, 110mm dia.m296.64296.64471.5FalseNoneNoneFalseNoneFalse139865.760
3926437151422Nonecode234Providing UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. complete for: Pipes of SN 4, 160mm dia.m717.91717.91200.0FalseNoneNoneFalseNoneFalse143582.00
3926438151422Nonecode235Providing and fixing brass bib cock of approved quality : 15 mm nominal boreNo294.58294.58204.0FalseNoneNoneFalseNoneFalse60094.320
3926439151422Nonecode236Providing and fixing brass bib cock of approved quality : 20 mm nominal boreNo314.15314.1531.0FalseNoneNoneFalseNoneFalse9738.650
3926440151422Nonecode237Providing and fixing brass stop cock of approved quality : 15 mm nominal boreNo307.97307.97204.0FalseNoneNoneFalseNoneFalse62825.880
3926441151422Nonecode238Providing and fixing brass stop cock of approved quality : 20 mm nominal boreNo314.15314.1531.0FalseNoneNoneFalseNoneFalse9738.650
3926442151422Nonecode239Providing and fixing floor mounted, white vitreous china single piece, double traps syphonic water closet of approved brand/make, shape, size and pattern including integrated white vitreous china cistern of capacity 10 litres with dual flushing system, including all fittings and fixtures with seat cover, cistern fittings, nuts, bolts and gasket etc including making connection with the existing P/S trap, complete in all respect as per directions of Engineer-in-Charge.Each14638.3614638.362.0FalseNoneNoneFalseNoneFalse29276.720
3926443151422Nonecode240Providing and fixing Single flow hand showers with Anti lime jets with 1.5m PVC tube and holder made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete - Class EconomyNo913.61913.6142.0FalseNoneNoneFalseNoneFalse38371.620
3926444151422Nonecode241Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer.No4244.634244.632.0FalseNoneNoneFalseNoneFalse8489.260
3926445151422Nonecode242Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories completeEach226.6226.699.0FalseNoneNoneFalseNoneFalse22433.40
3926446151422Nonecode243Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Each1256.61256.650.0FalseNoneNoneFalseNoneFalse62830.00
3926447151422Nonecode244Providing and fixing toilet paper holder : C P BrassEach626.24626.242.0FalseNoneNoneFalseNoneFalse1252.480
3926448151422Nonecode245Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 02mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 g.No103.0103.050.0FalseNoneNoneFalseNoneFalse5150.00
3926449151422Nonecode246Supply of PPR Gate valve confirming to IS 15801-2008 and DIN Standards 8077/8092 - PPR Gate valve 20mmEach389.34389.3423.0FalseNoneNoneFalseNoneFalse8954.820
3926450151422Nonecode247Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screwwith concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g.Each510.88510.8842.0FalseNoneNoneFalseNoneFalse21456.960
3926451151422Nonecode248Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge.Each5728.865728.862.0FalseNoneNoneFalseNoneFalse11457.720
3926452151422Nonecode249Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet :100 mm diameterNo264.71264.712.0FalseNoneNoneFalseNoneFalse529.420
3926453151422Nonecode250Providing and fixing Stainless Steel Grab Bar 600 mm Long with all concealed fitting arrangements & all necessary accesories complete - Class - b) PremiumNo8403.778403.773.0FalseNoneNoneFalseNoneFalse25211.310
3926454151422Nonecode251Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lidEach4983.144983.1440.0FalseNoneNoneFalseNoneFalse199325.60
3926455151422Nonecode252Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. Do with - 50 mm nominal dia Pipesm742.63742.63209.2FalseNoneNoneFalseNoneFalse155358.1960
3926456151422Nonecode253Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. Do with - 40 mm nominal dia Pipesm491.31491.31202.5FalseNoneNoneFalseNoneFalse99490.2750
3926457151422Nonecode254Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. Do with - 32 mm nominal dia Pipesm383.16383.16100.0FalseNoneNoneFalseNoneFalse38316.00
3926458151422Nonecode255Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. Do with - 25 mm nominal dia Pipesm304.88304.88257.0FalseNoneNoneFalseNoneFalse78354.160
3926459151422Nonecode256Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work. Do with - 20 mm nominal dia Pipesm223.51223.5147.0FalseNoneNoneFalseNoneFalse10504.970
3926460151422Nonecode257Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark - For 25 mm dia GM (Copper alloy) Gate valvesEach1204.071204.073.0FalseNoneNoneFalseNoneFalse3612.210
3926461151422Nonecode258Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark - For 32 mm dia GM (Copper alloy) Gate valvesEach1378.141378.144.0FalseNoneNoneFalseNoneFalse5512.560
3926462151422Nonecode259Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark - For 40 mm dia GM (Copper alloy) Gate valvesEach1545.01545.04.0FalseNoneNoneFalseNoneFalse6180.00
3926463151422Nonecode260Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark - For 50 mm dia GM (Copper alloy) Gate valvesEach1738.641738.644.0FalseNoneNoneFalseNoneFalse6954.560
3926464151422Nonecode261Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata. All kinds of soils. Depth upto 1.50 mCum269.86269.8664.1FalseNoneNoneFalseNoneFalse17298.0260
3926465151422Nonecode262Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.Each4363.084363.089.0FalseNoneNoneFalseNoneFalse39267.720
3926466151422Nonecode263Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and coverEach5617.625617.6213.0FalseNoneNoneFalseNoneFalse73029.060
3926467151422Nonecode264Supplying, installation, testing and commissioning of solar hot water heater comprising of solar Flat Plate Collector (FPC) of size 2120x1040x100mm and stainless steel hot water storage tank with stainless steel heat exchanger absorber made of copper sheet and copper tube of following capacity aluminium box collector with appropriate capacity electrical back up arrangement excluding inlet and out let pipes. SS Model with 100mm thick of 48Kg/M3 density Rock wool insulation with 22SWG Aluminium cladding. - 300 litresEach69986.069986.04.0FalseNoneNoneFalseNoneFalse279944.00
3926468151422Nonecode265Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm - Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.5M depth & SFRC Cover & FrameEach42815.0442815.042.0FalseNoneNoneFalseNoneFalse85630.080
3926469151422Nonecode266Construct Brick masonry in CM 1:4, 340 mm thick, with wirecut bricks of approved quality, plaster inside and out side with CM 1:3, 12mm thick, except for the conical surface outside where the plaster thickness shall be 20mm. Slope inside to be 1:6 in the concrete towards central drain and finished smooth. Fixing of pipes in CC 1:2:4 with graded metal of 20mm and down size. Providing and fixing SFRC Machinehole frame and cover (Heavy Duty) conforming to IS:12592 with latest amendment, in CC 1:2:4. Providing and fixing footsteps made of 12mm dia. steel bars (Fe-500) with 3mm thick plastic encapsulation (IS-10910). The footsteps shall be fixed 30cms apart and on CC block embeded to masonry wall. The whole works include watering, curing, barricading, danger lighting, pouring tar over MH frame and cover, cost of tar, shoring, strutting, de-watering, engraving Machinehole number with flow direction on the inner conical surface etc. as per the drawing etc. as per technical specifications and for the following diameters and depth etc. for 1.2mm - Constructing Brick Masonry Circular Machinehole 1.2 m internal dia. , 1.2 M depth & SFRC coverEach32311.132311.12.0FalseNoneNoneFalseNoneFalse64622.20
3926470151422Nonecode267Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5 Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) without controls which shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. - Short Point up to 3 mtrs from tapping point to outlet via switchPoint277.07277.0765.0FalseNoneNoneFalseNoneFalse18009.550
3926471151422Nonecode268Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5 Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) without controls which shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.. - Medium point above 3m upto 6m from tapping point to out let via switchPoint390.37390.37130.0FalseNoneNoneFalseNoneFalse50748.10
3926472151422Nonecode269Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5 Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694: and latest amendments) without controls which shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.. - Long point above 6m upto 10m from tapping point to out let via switchPoint571.65571.6560.0FalseNoneNoneFalseNoneFalse34299.00
3926473151422Nonecode270Supplying heavy gauge PVC conduit pipe......mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18 SWGGI fish wire wherever necessary - 19/20 mm dia 2 mm thickm67.9867.982250.0FalseNoneNoneFalseNoneFalse152955.00
3926474151422Nonecode271Supplying heavy gauge PVC conduit pipe......mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18 SWGGI fish wire wherever necessary - 25 mm dia 2 mm thickm80.3480.342800.0FalseNoneNoneFalseNoneFalse224952.00
3926475151422Nonecode272Supplying heavy gauge PVC Conduit Pipe.... dia.......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWGGI fish wire run throughout the conduit wherever necessary. - 19/20 mm dia 2 mm thickm70.0470.041200.0FalseNoneNoneFalseNoneFalse84048.00
3926476151422Nonecode273Supplying heavy gauge PVC Conduit Pipe.... dia.......mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWGGI fish wire run throughout the conduit wherever necessary. - 25 mm dia 2 mm thickm81.3781.37650.0FalseNoneNoneFalseNoneFalse52890.50
3926477151422Nonecode274Supplying and fixing PVC/metal conduit Deep junction box - 19/20 mm deep Junction boxEach50.4750.47175.0FalseNoneNoneFalseNoneFalse8832.250
3926478151422Nonecode275Supplying and fixing PVC/metal conduit Deep junction box - 25 mm deep Junction boxEach57.6857.6880.0FalseNoneNoneFalseNoneFalse4614.40
3926479151422Nonecode276Supplying And Fixing Metal Fan Box with Round Hook.No120.51120.51130.0FalseNoneNoneFalseNoneFalse15666.30
3926480151422Nonecode277Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.Cwall: 1-2 WayEach142.14142.1412.0FalseNoneNoneFalseNoneFalse1705.680
3926481151422Nonecode278Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.Cwall: 3 WayEach163.77163.7715.0FalseNoneNoneFalseNoneFalse2456.550
3926482151422Nonecode279Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.Cwall: 4 - 5 WayEach182.31182.3110.0FalseNoneNoneFalseNoneFalse1823.10
3926483151422Nonecode280Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.Cwall: 6 WayEach226.6226.610.0FalseNoneNoneFalseNoneFalse2266.00
3926484151422Nonecode281Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.Cwall: 8 WayEach268.83268.83104.0FalseNoneNoneFalseNoneFalse27958.320
3926485151422Nonecode282Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.Cwall: 10-12 WayEach328.57328.5712.0FalseNoneNoneFalseNoneFalse3942.840
3926486151422Nonecode283Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.: 1-2 ModuleEach141.11141.1112.0FalseNoneNoneFalseNoneFalse1693.320
3926487151422Nonecode284Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.: 3 ModuleEach165.83165.8315.0FalseNoneNoneFalseNoneFalse2487.450
3926488151422Nonecode285Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.: 4 ModuleEach180.25180.2510.0FalseNoneNoneFalseNoneFalse1802.50
3926489151422Nonecode286Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.: 6 ModuleEach241.02241.0210.0FalseNoneNoneFalseNoneFalse2410.20
3926490151422Nonecode287Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.: 8 ModuleEach292.52292.52104.0FalseNoneNoneFalseNoneFalse30422.080
3926491151422Nonecode288Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.: 10-12 ModuleEach354.32354.3212.0FalseNoneNoneFalseNoneFalse4251.840
3926492151422Nonecode289Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: 6A One Way SwitchEach105.06105.06552.0FalseNoneNoneFalseNoneFalse57993.120
3926493151422Nonecode290Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: 6A Two Way SwitchEach170.98170.9812.0FalseNoneNoneFalseNoneFalse2051.760
3926494151422Nonecode291Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: 6A Three Way socketEach176.13176.13140.0FalseNoneNoneFalseNoneFalse24658.20
3926495151422Nonecode292Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: Stepped Fan Regulator Two ModuleEach367.71367.71130.0FalseNoneNoneFalseNoneFalse47802.30
3926496151422Nonecode293Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: 16A One Way SwitchEach185.4185.46.0FalseNoneNoneFalseNoneFalse1112.40
3926497151422Nonecode294Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: 6A Bell PushEach182.31182.311.0FalseNoneNoneFalseNoneFalse182.310
3926498151422Nonecode295Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: 32A DP SwitchEach335.78335.784.0FalseNoneNoneFalseNoneFalse1343.120
3926499151422Nonecode296Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: 6/16A Universal SocketEach243.08243.0810.0FalseNoneNoneFalseNoneFalse2430.80
3926500151422Nonecode297Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: TV/Telephone SocketEach160.68160.684.0FalseNoneNoneFalseNoneFalse642.720
3926501151422Nonecode298Supplying and fixing of modular switch/socket/stepped electronic fan regulator/dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293: RJ45/I.O Outlet Cat-6Each347.11347.115.0FalseNoneNoneFalseNoneFalse1735.550
3926502151422Nonecode299Supplying and fixing one of 230V Ding dong bell and a flush type bell push with gang box fixed on necessary wooden or rawl plugs using NF screws with Remote. - Ding Dong BellEach253.38253.381.0FalseNoneNoneFalseNoneFalse253.380
3926503151422Nonecode300Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clA, bolts,nuts etc., with provision for fixing suitable type capacityMCB's single phase/3 phase/single door with powder coatedpainting Made out of 14 SWG MS enclosure. - III - Double Door, 12 Way SP & NEach2398.872398.871.0FalseNoneNoneFalseNoneFalse2398.870
3926504151422Nonecode301Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clA, bolts,nuts etc., with provision for fixing suitable type capacityMCB's single phase/3 phase/single door with powder coatedpainting Made out of 14 SWG MS enclosure. - III - Double Door, 6 Way TP & NEach5088.25088.25.0FalseNoneNoneFalseNoneFalse25441.00
3926505151422Nonecode302Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.: 32-40A 4 poleEach5301.415301.415.0FalseNoneNoneFalseNoneFalse26507.050
3926506151422Nonecode303Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.: 63A 4 poleEach5711.355711.351.0FalseNoneNoneFalseNoneFalse5711.350
3926507151422Nonecode304Supplying & fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 withShort circuit breaking capacity of 10K and complete wiring asrequired confirming to IEC 60898.: 6-32A SP MCBEach427.45427.4577.0FalseNoneNoneFalseNoneFalse32913.650
3926508151422Nonecode305Supplying & fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 withShort circuit breaking capacity of 10K and complete wiring asrequired confirming to IEC 60898.: 6-32A DP MCBEach761.17761.171.0FalseNoneNoneFalseNoneFalse761.170
3926509151422Nonecode306Supplying & fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 withShort circuit breaking capacity of 10K and complete wiring asrequired confirming to IEC 60898.: 40A TPN MCBEach3135.323135.329.0FalseNoneNoneFalseNoneFalse28217.880
3926510151422Nonecode307Supplying & fixing miniature circuit breakers on existingMCB distribution boards using necessary fixing materialsand 'C' Type curve, indicator ON/OFF, energy cross-3 withShort circuit breaking capacity of 10K and complete wiring asrequired confirming to IEC 60898.: 50-63A TPN MCBEach3180.643180.642.0FalseNoneNoneFalseNoneFalse6361.280
3926511151422Nonecode308Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010: 1.5 mSqmm26.7826.783500.0FalseNoneNoneFalseNoneFalse93730.00
3926512151422Nonecode309Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010: 2.5 mSqmm43.2643.266020.0FalseNoneNoneFalseNoneFalse260425.20
3926513151422Nonecode310Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010: 4.0 mSqmm64.8964.891200.0FalseNoneNoneFalseNoneFalse77868.00
3926514151422Nonecode311Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010: 6.0 mSqmm94.7694.76200.0FalseNoneNoneFalseNoneFalse18952.00
3926515151422Nonecode312Supplying of.....feet PVC Batten with integrated LED tube....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater Than 80. Power Input: 220-240V @ 50/60Hz & Power factor Greater Than 0.9 a long with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.: LED light fitting 1 x 4' - 20/22 WEach710.7710.7190.0FalseNoneNoneFalseNoneFalse135033.00
3926516151422Nonecode313Supplying of.....feet PVC Batten with integrated LED tube....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater Than 80. Power Input: 220-240V @ 50/60Hz & Power factor Greater Than 0.9 a long with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.: LED light fitting 1 x 4' - 36/40 WEach1307.071307.0730.0FalseNoneNoneFalseNoneFalse39212.10
3926517151422Nonecode314Fixing all types and all capacities of fluorescent/ false ceiling/ spotlight/ CFL/ LED fittings indoor on the wall/ ceiling/ rafters/ girders using 23/ 0.0076" twint wisted PVC insulated wires, required Nos of round blocks and clamps. - On wall/ ceiling / Rafter / GirdersEach125.66125.66220.0FalseNoneNoneFalseNoneFalse27645.20
3926518151422Nonecode315Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIGreater Than 70%. efficacy Greater Than80 lumen per W, lifeGreater Than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF Greater Than 0.95, power loss should Less Than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. Theoperating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.: 9W, 6500KEach158.62158.6235.0FalseNoneNoneFalseNoneFalse5551.70
3926519151422Nonecode316Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopiesetc, for operation on 230V, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. - 48" Sweep (1200 mm) Regular modelEach3073.523073.52130.0FalseNoneNoneFalseNoneFalse399557.60
3926520151422Nonecode317Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5A. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. - Fixing Ceiling FansEach176.13176.13130.0FalseNoneNoneFalseNoneFalse22896.90
3926521151422Nonecode318Supplying of 1440 rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. - 12" Sweep (300 mm)Each3058.073058.0720.0FalseNoneNoneFalseNoneFalse61161.40
3926522151422Nonecode319Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5A. Ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire.Each506.76506.7620.0FalseNoneNoneFalseNoneFalse10135.20
3926523151422Nonecode320Fabrication suppling and mountuing MS box, made out SWG suitable floor / wall mounting , fully weather proof with privision for better heat disspation , provided with hinged front cover, equipped with temper proof locking arrangements , with suitable size clamps with necessary cable entey pipe with gland and box should be finsihed with 7 tanks treatment with powder coated paint and finllay finished with approved colour etc,.. complete. - 16 SWGSq CM0.440.44337500.0FalseNoneNoneFalseNoneFalse148500.00
3926524151422Nonecode321Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.: FOUR Pole 100 A 25 kAEach8741.618741.611.0FalseNoneNoneFalseNoneFalse8741.610
3926525151422Nonecode322Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism.: FOUR Pole 160 A 25 kAEach13850.4113850.412.0FalseNoneNoneFalseNoneFalse27700.820
3926526151422Nonecode323Supplying.........A rated 3 phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/ FRP/ DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete: 250 A 4 x 30 x 10 mm Aluminium Stripsm3538.053538.0528.0FalseNoneNoneFalseNoneFalse99065.40
3926527151422Nonecode324Supply and fixing of angle iron frame work fabricated out of ms angle iron,.. With bolts , washer, etc, and painted with 2 coat of red oxide and then two coats of approved paint. - 50 x 100 x 50 x 6 mm C channelm778.68778.6812.0FalseNoneNoneFalseNoneFalse9344.160
3926528151422Nonecode325Supplying and fixing of Shunt trip suitable for MCCB.CBCTEach1754.091754.091.0FalseNoneNoneFalseNoneFalse1754.090
3926529151422Nonecode326Supplying, fixing and wiring 0 to 600V 96x96mm AC Voltmeter on existing panel/wood board.Each465.56465.561.0FalseNoneNoneFalseNoneFalse465.560
3926530151422Nonecode327Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230/440VAC. 50 Hz 12/24V D.C.Each530.45530.456.0FalseNoneNoneFalseNoneFalse3182.70
3926531151422Nonecode328Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50Hz AC with latest micro controller based, digital read out of percentage leakage current, programmable delay/ auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board.Each9532.659532.651.0FalseNoneNoneFalseNoneFalse9532.650
3926532151422Nonecode329Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm allround with alterate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.GI pipe earthing make-TATA/GENITH,JINDAL.No4383.684383.688.0FalseNoneNoneFalseNoneFalse35069.440
3926533151422Nonecode330Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required.: 25 x 3 mm GI stripm84.4684.46150.0FalseNoneNoneFalseNoneFalse12669.00
3926534151422Nonecode331Supplying and fixing of LED Bulk head of 10W with IP 65 protection and IK08 impact resistance suitable for surface and wall mounting applications.Each867.26867.265.0FalseNoneNoneFalseNoneFalse4336.30
3926535151422Nonecode332Supplying of on Auto load change over switches 4 poles, AC-23A Duty, 415V, 50Hz, AC Supply. With all accessories. (SM Enclosure Sheet Metal Execution): 200 AEach15706.4715706.471.0FalseNoneNoneFalseNoneFalse15706.470
3926536151422Nonecode333Fixing of..... A TPST / change overs witch / Contactor along with neutral link with screws, bolts, nuts and wiring using required capacity wires and circuit labelling. - 100A to 250A TPSTEach460.41460.411.0FalseNoneNoneFalseNoneFalse460.410
3926537151422Nonecode3341.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975: 95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm)Km384411.45384411.450.03FalseNoneNoneFalseNoneFalse11532.34350
3926538151422Nonecode3351.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975: 25 Sqmm, 3.5 Core, (12 GI Strips - 4 x 0.8 mm)Km143735.47143735.470.03FalseNoneNoneFalseNoneFalse4312.06410
3926539151422Nonecode3361.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975: 16 Sqmm, 4 Core, (11 GI Strips - 4 x 0.8 mm)Km146097.26146097.260.1FalseNoneNoneFalseNoneFalse14609.7260
3926540151422Nonecode337Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable - 3.5 x 70/95/120 SqmmSet393.46393.466.0FalseNoneNoneFalseNoneFalse2360.760
3926541151422Nonecode338Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable - Up to 4C x 50 SqmmSet333.72333.7210.0FalseNoneNoneFalseNoneFalse3337.20
3926542151422Nonecode339Aluminium End Terminal (Lug) - 95 SqmmNo15.4515.4524.0FalseNoneNoneFalseNoneFalse370.80
3926543151422Nonecode340Aluminium End Terminal (Lug) - 25 SqmmNo3.093.0916.0FalseNoneNoneFalseNoneFalse49.440
3926544151422Nonecode341Aluminium End Terminal (Lug) - 16 SqmmNo2.062.0616.0FalseNoneNoneFalseNoneFalse32.960
3926545151422Nonecode342Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable - 35 to 95 SqmmKm32073.1732073.170.03FalseNoneNoneFalseNoneFalse962.19510
3926546151422Nonecode343Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable - 2.5 to 25 SqmmKm21512.5821512.580.1FalseNoneNoneFalseNoneFalse2151.2580
3926547151422Nonecode344Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work. - In all kinds of soils. Depth upto 1.50mm498.52498.5220.0FalseNoneNoneFalseNoneFalse9970.40
3926548151422Nonecode345Fabricating, supplying and erection of...ms long hot dip Galvanized Octagonal hot dip Pole with BSEN10025 grade S355JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, Bakelite sheet and MCBs as per IS specifications suitable to with stand the wind speed of 47 m/s for.......m Pole in single section and single joint welded as per IS 9595 / IS 10178 AWS having dimensions bottom.....mm, top....mm with 3mm thick, suitable base plate and 4 Nos of..... long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65 micron as per ASTM- A 123 and 153 etc.,(excluding foundation) as per drawing appended. - 9 m - Top 70 mm and Bottom 155 mm diaEach20085.020085.01.0FalseNoneNoneFalseNoneFalse20085.00
3926549151422Nonecode346Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4" dia telescopic M.S. pipe, with 2" dia 1.5m long M.S. Bracket and are welded with suitable angle, using 6mm thick M.S.sheet, grip bolts & nuts, as required, suitable for 9 to 12ms. M.S. tubular pole, with necessary two coats of painting, with all other accessories. - Single bracket 1.5 m. LengthNo1504.831504.831.0FalseNoneNoneFalseNoneFalse1504.830
3926550151422Nonecode347Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT Greater Than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire Greater Than IK08. Power Factor Greater Than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED EfficiencyGreater Than130lm/w, nominal CRI Greater Than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. - LED Streetlight 90 WEach9125.89125.81.0FalseNoneNoneFalseNoneFalse9125.80
3926551151422Nonecode348Fixing halogen / metal halide / SVL / IL / LED flood light fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.Each166.86166.861.0FalseNoneNoneFalseNoneFalse166.860
3926552151422Nonecode349Supplying and drawing Flexible Multi core Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 - 3C x 1.5 mm2m74.1674.1612.0FalseNoneNoneFalseNoneFalse889.920
3926553151422Nonecode350Supplying and drawing UTP-CAT 6E LAN cable.m39.1439.14549.0FalseNoneNoneFalseNoneFalse21487.860
3926554151422Nonecode351Supplying & Fixing of ... ms Cat 6 Patch Cable - 2mEach264.71264.716.0FalseNoneNoneFalseNoneFalse1588.260
3926555151422Nonecode352Supplying & Fixing of switch mounting rack with power manager & Cable manager. - 12U with 450mm depthEach9100.059100.051.0FalseNoneNoneFalseNoneFalse9100.050
3926556151422Nonecode353Supplying & Fixing of Power stripEach1500.711500.711.0FalseNoneNoneFalseNoneFalse1500.710
3926557151422Nonecode354Supplying fixing of Network Switches: 8 port 10/100 SwitchEach1081.51081.51.0FalseNoneNoneFalseNoneFalse1081.50
3926558151422Nonecode355Supply Installation Testing 32Channel Digital Video Recorder with Video Input, Real Time recording DVR & AV compatible, improved clarity for better recognition, longer recording time, extended range of features, multiple interfacing options, image quality with all required accessories including all labour charges etc completeEach38000.038000.01.0FalseNoneNoneFalseNoneFalse38000.00
3926559151422Nonecode356Supply & Installation of indoor fixed dome camera with 720TVL ,1/3" Super HAD CCD colour, 3.6mm fixed lens,2 mega picsels, Day & Night IR LED & supports 15Mtr distance, enhanced picture quality, reliability mounted on ceilings or walls with all required accessories including all labour charges etc complete.Each9750.09750.010.0FalseNoneNoneFalseNoneFalse97500.00
3926560151422Nonecode357Supply & Installation of Outdoor bullet camera with 650TVL,Day & Night IR LED supports 60 Mtr distance, 4 mega piicsels , HD, enhanced picture quality, reliability mounted on ceiling or walls,with IP55 Enclosure with all required steel supports ,accessories including all labour charges etc complete.Each16247.016247.04.0FalseNoneNoneFalseNoneFalse64988.00
3926561151422Nonecode358Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. etc. complete.Each5446.645446.641.0FalseNoneNoneFalseNoneFalse5446.640
3926562151422Nonecode359Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: (Above 300m of drilling add 10% for every 50m depth): Borewell depth of 0 to 50 Mtrsm318.27318.2750.0FalseNoneNoneFalseNoneFalse15913.50
3926563151422Nonecode360Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: (Above 300m of drilling add 10% for every 50m depth): Borewell depth of 50 to 100 Mtrsm398.61398.6150.0FalseNoneNoneFalseNoneFalse19930.50
3926564151422Nonecode361Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: (Above 300m of drilling add 10% for every 50m depth): Borewell depth of 100 to 150 Mtrsm424.36424.3650.0FalseNoneNoneFalseNoneFalse21218.00
3926565151422Nonecode362Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: (Above 300m of drilling add 10% for every 50m depth): Borewell depth of 150 to 200 Mtrsm492.34492.3450.0FalseNoneNoneFalseNoneFalse24617.00
3926566151422Nonecode363Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: (Above 300m of drilling add 10% for every 50m depth): Borewell depth of 200 to 250 Mtrsm576.8576.850.0FalseNoneNoneFalseNoneFalse28840.00
3926567151422Nonecode364Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: (Above 300m of drilling add 10% for every 50m depth): Borewell depth of 250 to 300 Mtrsm610.79610.7950.0FalseNoneNoneFalseNoneFalse30539.50
3926568151422Nonecode365Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty.m1990.991990.9930.0FalseNoneNoneFalseNoneFalse59729.70
3926569151422Nonecode366Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge.Each168.92168.921.0FalseNoneNoneFalseNoneFalse168.920
3926570151422Nonecode367Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendmentsEach154.5154.52.0FalseNoneNoneFalseNoneFalse309.00
3926571151422Nonecode368Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. For 3 HP etc. complete. - 7.50 HP - 135 LPM @ 140 m = 12 STG Outlet Dia - 2.00"Each37718.637718.61.0FalseNoneNoneFalseNoneFalse37718.60
3926572151422Nonecode369Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar and other end fitted with protective cover). - 50 mmEach3141.53141.550.0FalseNoneNoneFalseNoneFalse157075.00
3926573151422Nonecode370Labour charges for Erection of new / repaired submersible pump set along with GI pipes (32mm / 50mm), cable (New submersible pump set if required will be supplied by the department free of cost and released pump set should be handed over to department) including transportation (Each length = 6 m)Job192.61192.6150.0FalseNoneNoneFalseNoneFalse9630.50
3926574151422Nonecode371Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. - 1x3x6 Sqm.m190.55190.55330.0FalseNoneNoneFalseNoneFalse62881.50
3926575151422Nonecode372Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments. - Size 50 mmEach1287.51287.51.0FalseNoneNoneFalseNoneFalse1287.50
3926576151422Nonecode373Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete. - for outdoor - 6 to 15 HP pumpsEach18025.018025.01.0FalseNoneNoneFalseNoneFalse18025.00
3926577151422Nonecode3741.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 - 16 Sqmm, 2 Core, (9 GI Strips - 4 x 0.8 mm)Km88418.088418.00.3FalseNoneNoneFalseNoneFalse26525.40
3926578151422Nonecode375Providing, Laying and Fixing of GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) For:Heavy Duty GI Pipe etc. complete. - Medium Duty GI pipe of 65mm diam740.57740.5710.0FalseNoneNoneFalseNoneFalse7405.70
3926579151422Nonecode376Epoxy Terminating Kit (Pothead) suitable for 1.1 kV, LTUG Cable. - Up to 4C x 50 SqmmSet324.0324.01.0FalseNoneNoneFalseNoneFalse324.00
3926580151422Nonecode377Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Final rate is including Shuttering) -M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. - UG SUMPCum6512.696512.6932.86FalseNoneNoneFalseNoneFalse214006.99340
3926581151422Nonecode378Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. - UG SUMPSqm321.36321.3677.0FalseNoneNoneFalseNoneFalse24744.720
3926582151422Nonecode379Providing and supplying crystalline integral concrete waterproofing admixture that waterproofs concrete by forming crystals deep in the pores, capillaries and microcracks of the concrete, self-seal waterproofing compound to bridge shrinkage cracks upto 0.5mm in width & resist hydro-static pressure upto 16bar for both positive & negative pressure confirming to DIN 1048 part 5 for 56% reduction in depth of penetration against control, resistance to chloride penetration confirming to ASTM C 1202 with 64% improvement against control & protecting steel reinforcement against corrosion mixed @ 1% by weight of cementitious content in concrete. ie., integral crystaline waterproofing admix @ 0.5 kg/bag of cement. (For calculation purpose 320 kg of Cement for M-20 grade of Concrete is considered in the analysis)Sqm633.45633.4557.5FalseNoneNoneFalseNoneFalse36423.3750
3926583151422Nonecode380Providing & fixing 455x610 mm cast iron cover with frame weight to be not less 38kgs (weight of cover 23 kgs and weight of frame 15 kgs)and necessary locking arrangements with M.S flats 32x6 mm etc & painting with two or more coats with black Japan paint etc. complete as directed by the engineer-in-charge.Each2020.862020.862.0FalseNoneNoneFalseNoneFalse4041.720
3926584151422Nonecode381Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete. - Upto 3 HP pumpsEach6695.06695.01.0FalseNoneNoneFalseNoneFalse6695.00
3926585151422Nonecode382Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch) suitable for bore well confirming to IS 8034-2000 specifications, to work site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete. - 3.00 HP/2.2KW - 9 STGEach20716.3920716.392.0FalseNoneNoneFalseNoneFalse41432.780
3926586151422Nonecode383Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments. - 1x3x6 Sqm.m190.55190.5530.0FalseNoneNoneFalseNoneFalse5716.50
3926587151422Nonecode384Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.Cum1032.061032.0612.56FalseNoneNoneFalseNoneFalse12962.67360
3926588151422Nonecode385Supplying, filling, spreading &leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineerin- charge.Cum1221.581221.5812.56FalseNoneNoneFalseNoneFalse15343.04480
3926589151422Nonecode386Supplying, filling, spreading &leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge.Cum1227.761227.7612.56FalseNoneNoneFalseNoneFalse15420.66560
3926590151422Nonecode387Providing and laying 100mm thick pre-cast cover slabs over drains & Rain pit of width not exceeding 800 mm using M20 concrete reinforced with Micro Alloyed High carbon steel with 3mm - 3ply wired steel @ 2.00 kg/m2, slabs jointed in CM 1:3 proportion and nicely finished Including providing holes in the Cover slabs wherever necessary for easy drainage of surface water including of labour, materials, scaffolding, usage of machinery, curing, lead and lift charges etc, Complete.Sqm955.84955.845.76FalseNoneNoneFalseNoneFalse5505.63840
3926591151422Nonecode388Design, supplying, erecting testing and commissioning of - Passenger/ Bed - cum - passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V3 phase 50 cycles AC supply, powder coated/ Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED carillumination, emergency light, inter comand fan as desired by the user, central opening/ side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fire mandrive, SS hand rails inside car, full length infra red curtain in car door, automatic rescue device with batteries, voice announcing in regional/ international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.,The total product and services shall adhere to IS 14665 /2016 (with latest amendments) part/ section 1 to 5 with regards to general guidelines of fire safety rated doors, MRLL beams, pressures witch, manual change over for doors during emergency, ARD of 10 times with sufficient battery backup and standard dimensions of chair car and door openings for all sizes and capacities of lifts including fitness certificate and duly observing all other safety norms prescribed and adhere to CPWD specifications, PCB Norms, National Electricity Code (NEC), NBC-2016, IEC and Karnataka State Lifts, Escalators and Passengers Conveyers Act 2012 and Rules 2014. The Supplier shall be registered in Government Electrical Inspectorate in the State of Karnataka. - D With Out Machine Room-SS Finish - Capacity of 13 Passengers - 5 StopsJob1884540.141884540.141.0FalseNoneNoneFalseNoneFalse1884540.140
3926592151422Nonecode389Waste water Treatment by Bio Sewage Treatment Plant (Bio STP) onsite construction [25 KLD and 50 KLD ]: Providing, installation and commissioning of anaerobic Bio Sewage Treatment Plant (Bio STP) for black water with all necessary accessories such as pre- filter, pipes for the onsite constructed ABD tank as per the prescribed specification, according to the capacity, with a baffle wall to control the flow of water and to increase the retention time in the RCC ABD Tank. It includes an internal matrix for enhanced growth of bacteria, rising and falling pipes. For grey water, pre - filter, oil skimmer is provided along with an aerator. Post filter such as sand and carbon filter are also included as per the enclosed detailed technical specification attached as Annexure-2, including cost of material, loading and unloading and as directed by the engineer in charge etc., complete, including annual maintenance of the system for 5 years. Note: 1. Above rates mentioned are for the preparation of estimate purpose only. 2. All items are of ISI standards. 3. After commissioning of plant necessary testing to be done for the Satisfaction of the Engineer in charge. 4. Design drawing of the system suitable for erection 50 KLD is given in figure for reference. - 50 KLDEach2621350.02621350.01.0FalseNoneNoneFalseNoneFalse2621350.00
3926593151422Nonecode390Cost of Haulage Excluding Loading and Unloading - Case-1 : Surfaced Road - a Taking output 10 t load and lead 10 km = 100 kmKm15.8215.82247.5FalseNoneNoneFalseNoneFalse3915.450
3926594151422Nonecode391Supplying and fixing M15 grade precast cement concrete Kerb stones for Roadway, Sidewalls and gutters fixed with CM 1:3 fixed and finsihed in line as per direction of Engineer in charge. (The cost of PCC shall be paid extra) - 600 x 300 x 100 mm sizem273.98273.98330.0FalseNoneNoneFalseNoneFalse90413.40
3926595151422Nonecode392Supply, Installation, Testing and Commissioning of ongrid Solar Photovoltaic Power Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 330 Wp or above, manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz +/- 2.5 Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. c) Data Monitoring System complete with accessories. d) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. e) Lightning and surge voltage protection. f) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required.Each61060.061060.05.0FalseNoneNoneFalseNoneFalse305300.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17255195820000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17255195820000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17255195820000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17255195820000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17255195820000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17255195840000NoneNoneELIGIBILITYThe tender document is part and parcel of the agreement.None
17255195870000NoneNoneELIGIBILITYThe contractor shall obtain insurance coverage for all the workers deployed for this work.None
17255195910000NoneNoneELIGIBILITYFurther details of the work or any clarifications can be obtained from the office of the Executive Engineer (Central office), KHB, Cauvery Bhavan, K.G. Road, Bangalore Ph: 080-22273511 ext-317,None
17255195950000NoneNoneELIGIBILITYThe intending bidders are requested to note that they should abide by the detailed instructions and conditions contained in the Tender documents and further modifications done if any.None
17255196230000NoneNoneELIGIBILITYKHB reserves the right to withdraw or cancel this invitation to BID/Tender without assigning any reason whatsoeverNone
17255196270000NoneNoneELIGIBILITYThe bidder shall study the Tender document Carefully and quote the ratesNone
17255196300000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and are to be produced to the Executive Engineer to verify the documents within 3 days from the day of opening of Technical bid for verification, if required.None
17255196340000NoneNoneELIGIBILITYDrawings uploaded are only for Tender Purpose only.None
17255196380000NoneNoneELIGIBILITYGST shall be added separately in the estimate.None
17255196400000NoneNoneELIGIBILITYGST shall be paid to the tendered amount separately.None
17255196430000NoneNoneELIGIBILITYThe bidder should maintain register of laborers deployed and wages paid for the workers and shall produce the documents whenever called for by the competent authority. Remittance towards PF shall be commensurate with the labour component of the work involved.None
17255196460000NoneNoneELIGIBILITYThe bidder shall give an undertaking that they would abide by the provisions of employees provident fund and shall remit PF of labourers to the respective PF offices or else KHB have the right to deduct the PF amount from the work bills and remit the same to respective PF offices.None
17255196510000NoneNoneELIGIBILITYThe contractor shall quote his rates inclusive of PF as per the applicable rate as issued by the PF department from time to timeNone
17255196550000NoneNoneELIGIBILITYThe successful bidder shall give an under taking that they would abide by the provisions of the Employees Provident Fund Act.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneScanned Copy of documentary proof for having executed similar nature of work not less than 50% of tender amount as defined in Government order No.FD 480 EXP-12/2014,Bangalore dated:19.07.2014Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneScanned copy of Pre-qualification letter issued by Karnataka Housing Board.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of Pre-qualification letter issued by Karnataka Housing Board.
NoneNoneNoneNoneAs per Tender Documents KW-4 clause 3.3 key & critical equipments available.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- As per Tender Documents KW-4 clause 3.3 key & critical equipments available.
NoneNoneNoneNoneExecuted in any one Financial year, the minimum quantities of work as mentioned in tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Executed in any one Financial year, the minimum quantities of work as mentioned in tender document
NoneNoneNoneNoneRequired valid electrical license for executing similar nature of work as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Required valid electrical license for executing similar nature of work as per tender document
NoneNoneNoneNoneThe Tenderer should have executed similar water supply/sanitary engineering works as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The Tenderer should have executed similar water supply/sanitary engineering works as per tender document
NoneNoneNoneNoneIncome Tax returns & PANFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneGST Registration CertificateFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneTo qualify for award of this contract , each tenderer in its name should have in the last five years achieved in at least two financial years a minimum financial turnover (In all classes of civil engineering construction works only)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneScanned copy of latest GST clearance certificate.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of latest GST clearance certificate.
NoneNoneNoneNoneScanned copy of Credit lines/ letter of credit /Bankers certificate for at least 20% of amount put to tender in the current financial year on the name of work put to tender.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneAssessed Available Bid Capacity as per tender documentFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Assessed Available Bid Capacity as per tender document
NoneNoneNoneNoneCovering letter.OthersCovering letter.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Covering letter.
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
Work done certificateTrueTechnical Bid
key and critical equipment LISTTrueTechnical Bid
Income Tax returns & PAN no.TrueTechnical Bid
Pre-qualification certificate issued by KHBTrueTechnical Bid
GST clearance certificateTrueTechnical Bid
Credit lines/ letter of credit/Bankers certificateTrueTechnical Bid
Assessed available tender capacity calculationTrueTechnical Bid
Electrical licenseTrueTechnical Bid
Work done certificate with quantitiesTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1725545046000
version0
createdDateNone
modifiedDateNone
blockNumberCAUVERY BHAVAN 3RD FLOOR
streetNone
cityBengaluru
stateKarnataka
pin560009
tenderRecallDTONone