3933776 | 152031 | None | PWD 1.14.1 | Earth work excavation for Foundation by mechanical means for all works &
depth upto 3 m, as per drawing and technical specifications, including setting
out, shoring, strutting, barricading, caution lights, including dressing of
excavated surfaces, disposing off or levelling the excavated earth or sorting
& stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5
m including cost of labour, tools, usage of machinery & other appurtenaces
required to complete the work | Cum | 107.1 | 107.1 | 12.5 | False | None | None | False | None | False | 1338.75 | 0 |
3933777 | 152031 | None | PWD 2.1.2 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 0.63 | False | None | None | False | None | False | 3746.736 | 0 |
3933778 | 152031 | None | PWD 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6931.42 | 6931.42 | 0.94 | False | None | None | False | None | False | 6515.5348 | 0 |
3933779 | 152031 | None | PWD 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10442.25 | 10442.25 | 12.7 | False | None | None | False | None | False | 132616.575 | 0 |
3933780 | 152031 | None | PWD 2.11a | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification. | Tonne | 93929.85 | 93929.85 | 0.04 | False | None | None | False | None | False | 3757.194 | 0 |
3933781 | 152031 | None | PWD 6.33 | Providing and constructing load bearing wall with Solid Concrete blocks
of size 400x150x200mm having block density more than 1800kg/m3
and minimum compressive strength of 4.00 N/mm2 conforming to IS
2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005
including cost of all materials, labour, scaffolding and curing, usage
charges of machinery etc complete as per specifications. | Sqm | 1292.55 | 1292.55 | 44.25 | False | None | None | False | None | False | 57195.3375 | 0 |
3933782 | 152031 | None | PWD 11.11.1 | Providing and fixing factory made ISI marked steel glazed doors, windows
and ventilators, side /top /centre hung, with beading and all members
such as F7D,F4B, K11 B and K12 B etc. complete of standard rolled steel
sections, joints mitred and flash butt welded and sash bars tenoned
and riveted, including providing and fixing of hinges, pivots, including
priming coat of approved steel primer, but excluding the cost of other
fittings, complete all as per approved design, (sectional weight of only
steel members shall be measured for payment).
Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete
block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone
aggregate 20 mm nominal size) including cost of materials, labour, usage
charges of machinery complete as per specifications and as per directions
of the Engineer-in-Charge. | Kg | 155.4 | 155.4 | 275.1 | False | None | None | False | None | False | 42750.54 | 0 |
3933783 | 152031 | None | PWD 15.1 | Providing and laying water proofing treatment to the Roof with PU based
single component elastomeric pure polyurethane based coating on New
terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU wa
terproofing membrane that is highly elastic with elongation greater than
400% and tensile strength greater than 2MPa as per ASTM D412. The
waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve
final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy
primer @150 g/m2 and protection with 120gsm Geo-textile over the wa
terproofing membrane. The finished cost to include surface preparation,
making coving at Junction, Bore Packing, treatment of construction joints
completely as per specification. | Sqm | 857.85 | 857.85 | 56.0 | False | None | None | False | None | False | 48039.6 | 0 |
3933784 | 152031 | None | PWD 12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with
a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam
sheet metered cut at corners & jointed 2 No.s of 150mm long brackets
of 15x15mm M.S Square tube, the entire door frame to be reinforced with
19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the
wall using M.S. Screws of 65/80mm size complete as per manufacturers
specification & direction of Engineer-in-charge. | Sqm | 333.9 | 333.9 | 5.4 | False | None | None | False | None | False | 1803.06 | 0 |
3933785 | 152031 | None | PWD 12.55.1 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled
Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and
15x15mm for top & bottom rails, covered with heat moulded Prelaminated
PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm
thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom
rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert
for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated
on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC
Designer beading on either side & joined together with solvent cement
adhesive etc., Complete as per manufacturers specification & direction of
Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. | Sqm | 2484.3 | 2484.3 | 1.62 | False | None | None | False | None | False | 4024.566 | 0 |
3933786 | 152031 | None | PWD 11.15.2 | Providing and fixing M.S. Tubular frames for doors, windows,
ventilators and cupboard with rectangular/ L-Type sections, made of
1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with
profiles of required size, including fixing of necessary butt hinges and
screws and applying a priming coat of approved steel primer: Fixing
with carbon steel galvanised dash fastener of required dia and size (to
be paid for separately) including cost of materials, labour, usage charges
of machinery complete as per specifications and as per directions of the
Engineer-in-Charge. | Kg | 123.9 | 123.9 | 280.35 | False | None | None | False | None | False | 34735.365 | 0 |
3933787 | 152031 | None | PWD 11.30.1 | Providing & fixing glass panes with putty and glazing clips in steel
doors, windows, clerestory windows, all complete with : 4.0 mm thick
glass panes including cost of materials, labour, usage charges of machinery
complete as per specifications and as per directions of the Engineer-in
Charge. | Sqm | 957.6 | 957.6 | 8.01 | False | None | None | False | None | False | 7670.376 | 0 |
3933788 | 152031 | None | PWD 8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement:
3 coarse sand) finished with a floating coat of neat cement on the rough
side of single or half brick wall including rounding off corners wherever
required smooth rendering, providing and removing scaffolding, including
cost of materials, labour, curing complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 384.3 | 384.3 | 187.33 | False | None | None | False | None | False | 71990.919 | 0 |
3933789 | 152031 | None | PWD 8.9 | Providing 18 mm cement plaster in two coats under layer 12 mm thick
cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a
top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement
: 3 coarse sand) finished rough with sponge to brick masonry including
rounding off corners wherever required smooth rendering, providing and
removing scaffolding, including cost of materials, labour, curing complete
as per specifications and as per directions of Engineer-in-charge. | Sqm | 404.25 | 404.25 | 174.82 | False | None | None | False | None | False | 70670.985 | 0 |
3933790 | 152031 | None | PWD 9.21.2 | Providing and laying Vitrified tiles with thickness 9-10 mm in floor with
different sizes with water absorption less than 0.08% and conforming to
IS:15622, of approved brand & manufacturer, in all colours and shade, laid
with cement based high polymer modified quick set tile adhesive (water
based) conforming to IS : 15477, in average 6 mm thickness, including
grouting of joints (Payment for grouting of joints to be made separately) Size of Tile 600x600 mm | Sqm | 1202.25 | 1202.25 | 118.74 | False | None | None | False | None | False | 142755.165 | 0 |
3933791 | 152031 | None | PWD 9.39 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm
thick on 10mm thick cement plaster 1:3 and jointed with white cement
slurry over existing rough plaster surface using glazed tiles of approved
make and size including cost of materials, labour, complete as per
specifications | Sqm | 1521.45 | 1521.45 | 23.07 | False | None | None | False | None | False | 35099.8515 | 0 |
3933792 | 152031 | None | PWD A-19 | Cuddapah Slab 2.5 Cms thick | Sqm | 485.1 | 485.1 | 5.82 | False | None | None | False | None | False | 2823.282 | 0 |
3933793 | 152031 | None | PWD 14.1.1 | Providing and fixing water closet squatting pan (Indian type W.C. pan )
with 100 mm sand cast Iron P or S trap, 10 litre low level white
P.V.C. flushing cistern, including flush pipe, with manually controlled
device (handle lever) conforming to IS : 7231, with all fittings and fixtures
complete, including cutting and making good the walls and floors wherever
required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with
integral type foot rests | Each | 4485.3 | 4485.3 | 1.0 | False | None | None | False | None | False | 4485.3 | 0 |
3933794 | 152031 | None | PWD 1.23 | Providing and Filling in foundation with granite / trap broken metal 100mm. and
down size & with approved sand including hand packing, ramming, watering,
including cost of all materials and labour with all lead and lift complete as per
specifications | Cum | 2689.05 | 2689.05 | 1.94 | False | None | None | False | None | False | 5216.757 | 0 |
3933795 | 152031 | None | PWD 1217 | RCC Perforted rings 1200 mm* 1250mm | Each | 7350.0 | 7350.0 | 1.0 | False | None | None | False | None | False | 7350.0 | 0 |
3933796 | 152031 | None | PWD 9.26 | Providing and laying flooring with burnt stone slabs 10 cms thick, rough
chistle dressed on sand bed 7.5 cms to 8 cms thick and pointed with cement
mortar 1:3, , including cost of materials, sand, labour, curing complete as
per specifications. | Each | 2488.5 | 2488.5 | 1.44 | False | None | None | False | None | False | 3583.44 | 0 |
3933797 | 152031 | None | PWD 10.1 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest
amendments and conveying to worksite, rolling and lowering into
trenches, laying true to line and level and perfect linking at joints, testing
and commissioning, including loading unloading at both destinations
and cuts of pipes wherever necessary including jointing of PVC pipes
and specials (excluding cost of specials) with jointing of approved
type, with all labour with all lead & lift including encasing the pipe
alround to a depth of not less than 15 cms. with soft gravel or selected
earth available from the excavation etc. complete and giving necessary
hydraulic test to the required pressure as per ISS (Contractor will make
his own arrangements for procuring water for testing) etc Complete for PVC pipes 110mm dia., 6 kg/sqcm & class 3 | Mtr | 411.0 | 411.0 | 40.0 | False | None | None | False | None | False | 16440.0 | 0 |
3933798 | 152031 | None | PWD 10.11 | Supply and delivery at site special moulded variety PVC bend as per IS
7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its
latest amendments 110 mm dia PVC BEND | Each | 492.0 | 492.0 | 7.0 | False | None | None | False | None | False | 3444.0 | 0 |
3933799 | 152031 | None | PWD 10.9 | Supply and delivery at site special moulded variety PVC elbows as per
IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with
its latest amendments 110 mm dia PVC Elbows | Each | 302.0 | 302.0 | 3.0 | False | None | None | False | None | False | 906.0 | 0 |
3933800 | 152031 | None | PWD 10.10.8 | Supply and delivery at site special moulded variety PVC tee as per IS
7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its
latest amendments 110 mm dia PVC Tee | Each | 251.0 | 251.0 | 4.0 | False | None | None | False | None | False | 1004.0 | 0 |
3933801 | 152031 | None | PWD 13.31.2 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, including fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step
CPVC solvent cement and testing of joints complete as per direction of
Engineer in Charge. Internal work - Exposed on wall 20 mm nominal dia Pipe | Mtr | 254.1 | 254.1 | 30.0 | False | None | None | False | None | False | 7623.0 | 0 |
3933802 | 152031 | None | PWD 13.31.3 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes,
having thermal stability for hot & cold water supply, including all CPVC
plain & brass threaded fittings, including fixing the pipe with clamps at
1.00 m spacing. This includes jointing of pipes & fittings with one step
CPVC solvent cement and testing of joints complete as per direction of
Engineer in Charge. Internal work - Exposed on wall 25 mm nominal dia Pipes | Mtr | 333.9 | 333.9 | 30.0 | False | None | None | False | None | False | 10017.0 | 0 |
3933803 | 152031 | None | PWD 13.3.1 | Providing and fixing brass stop cock of approved quality : 15 mm nominal bore | Each | 313.95 | 313.95 | 5.0 | False | None | None | False | None | False | 1569.75 | 0 |
3933804 | 152031 | None | PWD 14.32.2 | Providing and fixing mirror of superior glass (of approved quality) and
of required shape and size with plastic moulded frame of approved make
and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm | Each | 1068.9 | 1068.9 | 1.0 | False | None | None | False | None | False | 1068.9 | 0 |
3933805 | 152031 | None | PWD 17.7.7 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar
taps, 32 mm C.P. brass waste of standard pattern, including painting of
fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 450x 300 mm with single
15mm C.P. brass pillar tap | Each | 2203.95 | 2203.95 | 2.0 | False | None | None | False | None | False | 4407.9 | 0 |
3933806 | 152031 | None | PWD 13.34A | Providing and fixing rectangular high density polyethylene water storage
loft tank with cover, conforming to ISI : 12701, colour of opaque white or
as approved by Engineer-in-charge. The rate includes making necessary
holes for inlet, outlet & over flow pipes. The base support i/c fittings &
fixtures for tank shall be paid separately | Ltr | 9.45 | 9.45 | 1000.0 | False | None | None | False | None | False | 9450.0 | 0 |
3933807 | 152031 | None | PWD 2.1.4 | Providing and laying in position Cement Concrete for levelling course for
all works in foundation. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in
layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of
machinery, curing, and all the other appurtenances required to complete the
work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6527.85 | 6527.85 | 0.63 | False | None | None | False | None | False | 4112.5455 | 0 |
3933808 | 152031 | None | PWD 8.51 | Providing and applying white cement based putty of average thickness
1 mm, of approved brand and manufacturer, over the plastered
wall surface to prepare the surface even and smooth complete as per
specifications and as per directions of Engineer in charge. | Sqm | 105.0 | 105.0 | 149.27 | False | None | None | False | None | False | 15673.35 | 0 |
3933809 | 152031 | None | PWD 8.33.1 | Finishing with Deluxe Multi surface paint system for interiors and exteriors
using Primer as per manufacturers specifications: Two coats applied on
walls @ 1.25 L/10 m² over and including one coat of Special primer applied
@ 0.75 L/10 m² with paint of approved quality to give an even shade, after
thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree
angle with 10 years life) | Sqm | 165.9 | 165.9 | 156.07 | False | None | None | False | None | False | 25892.013 | 0 |
3933810 | 152031 | None | PWD 8.25 | Distempering with oil bound washable distemper of approved brand
and manufacture to give an even shade :New work (two coats) over and in
cluding water thinnable priming coat with cement primer after thoroughly
brooming the surface to remove all dirt, dust, mortar drops and foreign
matter including preparing the surface even and sand paper smooth, cost
of materials, labour complete as per specifications and as per directions
of Engineer-in-charge. | Sqm | 143.85 | 143.85 | 69.43 | False | None | None | False | None | False | 9987.5055 | 0 |
3933811 | 152031 | None | PWD 8.32 | Finishing walls with 100% Premium acrylic emulsion paint having VOC
less than 50 g/L and UV resistance as per IS 15489:2004, Alkali
& fungal resistance, dirt resistance exterior paint of required shade
(Company Depot Tinted) with silicon additives, New work (Two coats
applied @ 1.43 L/ 10 m². Over and including priming coat of exterior
primer applied @ 0.90 L/10 m² with paint of approved quality to give an
even shade, after thoroughly brooming the surface to remove all dirt, dust,
mortar drops and foreign matter including preparing the surface even and
sand paper smooth, cost of materials, labour complete as per specifications
and as per directions of Engineer-in-charge | Sqm | 163.8 | 163.8 | 190.46 | False | None | None | False | None | False | 31197.348 | 0 |
3933812 | 152031 | None | PWD 8.4 | Painting with synthetic enamel paint of approved brand and
manufacture to give an even shade :Two coats on new work after
thoroughly brooming the surface to remove all dirt, dust, mortar drops
and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 115.0 | 115.0 | 31.34 | False | None | None | False | None | False | 3604.1 | 0 |
3933813 | 152031 | None | PWD 8.84 | Providing wall black boards in 12mm thick with CM 1:3 and applied with
primer & two coats of acrylic emulsion black paint including finishing
etc.,complete | Sqm | 498.75 | 498.75 | 2.0 | False | None | None | False | None | False | 997.5 | 0 |
3933814 | 152031 | None | PWD Sl65 | Brass 100mm mortice latch and lock with 6 levers with pair of handles | No | 204.75 | 204.75 | 2.0 | False | None | None | False | None | False | 409.5 | 0 |
3933815 | 152031 | None | PWD A14 | Brass double acting sring hinges 150 mm | No | 504.0 | 504.0 | 6.0 | False | None | None | False | None | False | 3024.0 | 0 |
3933816 | 152031 | None | PWD 12.63 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic
coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to
required colour or shade, with necessary screws etc. complete | No | 136.5 | 136.5 | 6.0 | False | None | None | False | None | False | 819.0 | 0 |
3933817 | 152031 | None | PWD 11.28 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow
tubes, channels, plates etc., including welding, grinding, buffing, polishing
and making curvature (wherever required) and fitting the same with
necessary stainless steel nuts and bolts complete, i/c fixing the railing
with necessary accessories & stainless steel dash fasteners, stainless
steel bolts etc., of required size, on the top of the floor or the side of waist
slab with suitable arrangement as per approval of Engineer-in- charge,
(for payment purpose only weight of stainless steel members shall be
considered excluding fixing accessories such as nuts, bolts, fasteners etc.)
including cost of materials, labour, usage charges of machinery complete
as per specifications and as per directions of the Engineer-in-Charge | Kg | 593.25 | 593.25 | 121.29 | False | None | None | False | None | False | 71955.2925 | 0 |
3933818 | 152031 | None | PWD 9.4 | Providing and laying Cement concrete pavement with 1:2:4 for commercial
& residential building floors, hardpaths, footpaths using 1 cement : 2 coarse
sand : 4 graded stone aggregate 20 mm nominal size, including finishing
complete as per Engineer incharge. | Cum | 6999.3 | 6999.3 | 1.88 | False | None | None | False | None | False | 13158.684 | 0 |
3933819 | 152031 | None | PWD 13.48 | Providing and fixing on wall face unplasticised Rigid PVC rain water
pipes conforming to IS : 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm ga | Mtr | 305.55 | 305.55 | 24.0 | False | None | None | False | None | False | 7333.2 | 0 |
3933820 | 152031 | None | PWD 1.1.1 | Supplying heavygaugePVCconduit pipe ....... dia .......mmthick
confirming to IS 2509 with suitable size bends, junction boxes,
adhesive pasteetc , andfixingusinginvertedwoodplugs incaseof
RCCceilingandRCCwall/ stonestructureor rawl plugs incaseof
brickwalls andcement plastering thedamagedportionusingheavy
gauge saddles at an interval of 700mm using NF screws 19/20 mm dia 2 mm thick | Rmtr | 69.0 | 69.0 | 180.0 | False | None | None | False | None | False | 12420.0 | 0 |
3933821 | 152031 | None | PWD 1.9.1 | Supplying PVC flexible conduit pipe ....mmdiafixingonsurface
overinvertedtaperedwooden plugs orphill plugsorrawlplugsand
clampedusingheavygaugesaddlesatanintervalof300mmusingNF
screws and on either end of the pipe terminated completely 20mm | Rmtr | 19.0 | 19.0 | 80.0 | False | None | None | False | None | False | 1520.0 | 0 |
3933822 | 152031 | None | PWD 1.7.1 | ExtraforGroovecuttinginbrickwall/CCfloor tothesuitabledepth
for concealing of Conduit/GI pipe and plastering, finishing upto
wall surface complete. upto 50 mm conduit in brick wall | Rmtr | 29.0 | 29.0 | 100.0 | False | None | None | False | None | False | 2900.0 | 0 |
3933823 | 152031 | None | PWD 2.3.2 | Wiringfor lighting/powercircuitusingoneof FRLSPVCinsulated
1100Vgrade,multistrandcopperwirewithlowconductor resistance
singlecore inopenorconcealedsystemofwiringwithspecifiedIS
694:2010. 1.5 mm2 | Rmtr | 26.0 | 26.0 | 200.0 | False | None | None | False | None | False | 5200.0 | 0 |
3933824 | 152031 | None | PWD 2.3.3 | Wiringfor lighting/powercircuitusingoneof FRLSPVCinsulated
1100Vgrade,multistrandcopperwirewithlowconductor resistance
singlecore inopenorconcealedsystemofwiringwithspecifiedIS
694:2010. 2.5 mm2 | Rmtr | 42.0 | 42.0 | 150.0 | False | None | None | False | None | False | 6300.0 | 0 |
3933825 | 152031 | None | PWD 2.3.4 | Wiringfor lighting/powercircuitusingoneof FRLSPVCinsulated
1100Vgrade,multistrandcopperwirewithlowconductor resistance
singlecore inopenorconcealedsystemofwiringwithspecifiedIS
694:2010. Mm2 | Rmtr | 63.0 | 63.0 | 120.0 | False | None | None | False | None | False | 7560.0 | 0 |
3933826 | 152031 | None | PWD 2.1.1 | Supplying and wiring adopting loop system in existing PVC
Conduit /casingcapping using2x1.5Sqmm(Phase&Neutral) &
1x1.0 sqmm(Earthwire) FRLSmultistrand PVC insulated
copper wire (confirming toIS-694:andlatestamendments)with
a6AmpsflushtypeSPcontrolswitchshallbefixedontheexisting
plasticsheet/gangbox, theotherendof thewiresshallbeterminated
withsufficient looselengthinawood/PVCroundblock.completefor
each outlet. Short point upto 3Mtr from tapping point to out let via switch | Point | 285.0 | 285.0 | 4.0 | False | None | None | False | None | False | 1140.0 | 0 |
3933827 | 152031 | None | PWD 2.1.2 | Supplying and wiring adopting loop system in existing PVC
Conduit /casingcapping using2x1.5Sqmm(Phase&Neutral) &
1x1.0 sqmm(Earthwire) FRLSmultistrand PVC insulated
copper wire (confirming toIS-694:andlatestamendments)with
a6AmpsflushtypeSPcontrolswitchshallbefixedontheexisting
plasticsheet/gangbox, theotherendof thewiresshallbeterminated
withsufficient looselengthinawood/PVCroundblock.completefor
each outlet. Mediumpointabove3Mtrupto6Mtrfromtappingpoint toout letvia
switch | Point | 394.0 | 394.0 | 4.0 | False | None | None | False | None | False | 1576.0 | 0 |
3933828 | 152031 | None | PWD 2.1.3 | Supplying and wiring adopting loop system in existing PVC
Conduit /casingcapping using2x1.5Sqmm(Phase&Neutral) &
1x1.0 sqmm(Earthwire) FRLSmultistrand PVC insulated
copper wire (confirming toIS-694:andlatestamendments)with
a6AmpsflushtypeSPcontrolswitchshallbefixedontheexisting
plasticsheet/gangbox, theotherendof thewiresshallbeterminated
withsufficient looselengthinawood/PVCroundblock.completefor
each outlet. Longpoint above6Mtrupto10Mtr fromtappingpoint toout letvia
switch | Point | 570.0 | 570.0 | 4.0 | False | None | None | False | None | False | 2280.0 | 0 |
3933829 | 152031 | None | PWD 3.8 | Supplying 4mm thick plastic sheet with necessary nitches for
fixing switches, regulators etc, and fixing on existingwoodenor
metal box using N.F. screws. | Sq CM | 0.41 | 0.41 | 4800.0 | False | None | None | False | None | False | 1968.0 | 0 |
3933830 | 152031 | None | PWD 3.14.1 | Supplying And fixing/replacing of 6/16/32A electrical
accessories on existing switch board. 6A SP Switch | No | 55.0 | 55.0 | 8.0 | False | None | None | False | None | False | 440.0 | 0 |
3933831 | 152031 | None | PWD 3.14.3 | Supplying And fixing/replacing of 6/16/32A electrical
accessories on existing switch board. 6A Three Way 5 Pin Socket | No | 70.0 | 70.0 | 3.0 | False | None | None | False | None | False | 210.0 | 0 |
3933832 | 152031 | None | PWD 6.3.1 | Supplyingcapacitor typeceilingfancompletewithdownrodblades,
shackle,canopiesetc,foroperationon230V,50cycles. Singlephase
ACsupplyconforming toISS-374-1979andwithdoubleballbearing
system. 48" Sweep (1200 mm) Regular model | No | 2984.0 | 2984.0 | 2.0 | False | None | None | False | None | False | 5968.0 | 0 |
3933833 | 152031 | None | PWD 5.19.1 | Supplyingand fixing regularMCBdistributionboards onwall/ood
board/ flushmountingusingrequiredclamps, bolts, nuts etc.,with
provision for fixing suitable type capacityMCB's single phase/3
phase/singledoorwith powdercoatedpaintingMadeoutof14SWG
MS enclosure. 4 Way SP & N | No | 1241.0 | 1241.0 | 1.0 | False | None | None | False | None | False | 1241.0 | 0 |
3933834 | 152031 | None | PWD 13.4 | Providing, Single Phase Submersible Pump Sets of 100mm dia (4 inch)
suitable for bore well confirming to IS 8034-2000 specifications, to work
site with testing of as per instructions of engineer incharge of work and latest amendments etc. complete. | Each | 15120.0 | 15120.0 | 1.0 | False | None | None | False | None | False | 15120.0 | 0 |