1724420938000 | 0 | None | None | Buildings | Construction of Material Recovery Facility centre (MRF) OF 91 TPD for Ballari City Corporation at SWM site. | 71549506.45 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3850322 | 147063 | None | code01 | Clearing and Grubbing Road Land Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness. CM SR 202324 P.No. 9Vol3 2.5 iiA By Mechanical Means using Dozer, In area of light jungle | 100 Sqm | 412.65 | 412.65 | 45.0638 | False | None | None | False | None | False | 18595.57707 | 0 | 3850323 | 147063 | None | code02 | Earth work excavation for foundation of structure upto 3 mtrs. By mechanicle means as per drawing and technical specification, including setting out, providing shoring, strutting and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, filling back the excavated earth to the extent required and utilising transporting the remaining earth upto 1.00km lead. including cost of labour, materials and HOM of machineries etc., complete OrdinaryHard Soil. In all kinds of soils Depth upto 3 m CM SR 202324 P.No. 8Vol1 1.14.1 | Cum | 107.1 | 107.1 | 1720.53 | False | None | None | False | None | False | 184268.763 | 0 | 3850324 | 147063 | None | code03 | Earth work excavation for foundation of structure upto 3 mtrs. By mechanicle means as per drawing and technical specification, including setting out, providing shoring, strutting and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom, filling back the excavated earth to the extent required and utilising transporting the remaining earth upto 1.00km lead. including cost of labour, materials and HOM of machineries etc., complete In ordinarysoft rock without blasting upto 1.5 m depth. In all kinds of soils Depth upto 3 m CM SR 202324 P.No. 8Vol1 1.15.1 | Cum | 381.15 | 381.15 | 191.17 | False | None | None | False | None | False | 72864.4455 | 0 | 3850325 | 147063 | None | code04 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as pertechnical specifications. The cost of steel reinforcement formwork shall be paid separately Mix 136 M10 Using 40 mm nominal size graded crushed coarse aggregates CM SR 202324 P.No.15Vol12.1.3 | Cum | 6288.45 | 6288.45 | 148.688 | False | None | None | False | None | False | 935017.0536 | 0 | 3850326 | 147063 | None | code05 | Providing Size Stone masonry with hard stone in foundation plinth with Cement mortar 16 1 cement 6 coarse sand CM SR 202324P.No.9Vol25.4 item for both Uncoursed and Coursed masonry | Cum | 6708.45 | 6708.45 | 412.2007 | False | None | None | False | None | False | 2765227.785915 | 0 | 3850327 | 147063 | None | code06 | Providing and laying in position Cement Concrete for all Foundation works. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.CM SR 202324P.No.15Vol12.2.5 M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7369.87 | 7369.87 | 502.5 | False | None | None | False | None | False | 3703359.675 | 0 | 3850328 | 147063 | None | code07 | Providing and laying in cement concrete for all Basement surface level works, return walls, retaining walls, sunken floors etc. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. CM SR 202324P.No.16Vol12.3.3 M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10402.88 | 10402.88 | 92.8629 | False | None | None | False | None | False | 966041.605152 | 0 | 3850329 | 147063 | None | code08 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works super structure works of bridges upto 3.50 m height. The granite trapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications CM SR 202324P.No.16Vol12.5.3 M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11771.76 | 11771.76 | 162.09 | False | None | None | False | None | False | 1908084.5784 | 0 | 3850330 | 147063 | None | code09 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works super structure works of bridges upto 3.50 m height. The granite trapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications CM SR 202324P.No.16Vol12.5.3 M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 12507.5 | 12507.5 | 270.111 | False | None | None | False | None | False | 3378413.3325 | 0 | 3850331 | 147063 | None | code10 | Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works super structure works of bridges upto 3.50 m height. The granite trapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications CM SR 202324P.No.16Vol12.5.3 M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11036.03 | 11036.03 | 30.6753 | False | None | None | False | None | False | 338533.531059 | 0 | 3850332 | 147063 | None | code11 | Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapingwelding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. CM SR 202324P.No.18Vol12.11 a | Tonne | 93929.85 | 93929.85 | 131.004 | False | None | None | False | None | False | 12305186.0694 | 0 | 3850333 | 147063 | None | code12 | Filling approved earth excluding rock in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. CM SR 202324P.No.7Vol11.11 Filling. | Cum | 454.65 | 454.65 | 2778.7505 | False | None | None | False | None | False | 1263358.914825 | 0 | 3850334 | 147063 | None | code13 | Construction of Granular SubBase of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 CM SR 202324P.No.23Vol34.1v | Cum | 2611.35 | 2611.35 | 916.618 | False | None | None | False | None | False | 2393610.4143 | 0 | 3850335 | 147063 | None | code14 | Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with pavergrader in subbase base course on well prepared surface and compacting with vibratory roller to achieve the desired density. CM SR 202324P.No.26Vol34.17 | Cum | 2686.95 | 2686.95 | 849.7135 | False | None | None | False | None | False | 2283137.688825 | 0 | 3850336 | 147063 | None | code15 | Providing and constructing unreinforced plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 Grade, coarse and fine aggregates conforming to IS3832016, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing, spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including construction joints, primer, sealant, curing of concrete slabs for 14days, and water finishing to lines and grade as per drawing and technical specification clause 1501 with all lead, lifts, loading unloading charges, cost and conveyance of all materials, labour, equipments etc., complete. as per the directions of the Engineerincharge of the work. CM SR 202324P.No.149Vol316.28 | Cum | 7091.7 | 7091.7 | 1097.618 | False | None | None | False | None | False | 7783977.5706 | 0 | 3850337 | 147063 | None | code16 | Providing and fixing of self supported mechanically seamed roofing system such as proflex, green curve, Kialash roofing or equivalent made of high strength quality steel, having 340 MPA yield strength, pre coated galvalume sheet as per ASTM A792 M of base metal thickness 1.4 mm Tolerance 0.02 mm. high grade steel sheet should have 55 aluminium and 45 Zinc coating by hot dip process of minimum 25 micron on top side and 12 micron on back side with epoxy primer and polyester wash coat as per AZM 150. Roofing should be designed as per ASCE 720 international building code 2002. The analysis should carried out for span and centre arch rise considering the required live load, wind load, dead load and seismic factor. The analysis should also determine the thickness of steel and the end reaction at the beam level. Shop drawing of roofing system shall be submitted by contractor through consultant and same shall be checked and approved by the department. The roof panel formation shall be done as per the required length and curvature using hydraulic profile machine to give it the trapezoidal shape in required curvature. In this process the width of sheet the width of sheet reduces from 0.914 meter to 0.61 meter tolerance 0.02 mm. The roof panel shall be lifted using a suitable crane and using a spreader bar and a sling evenly placed to ensure no distortion of panel till the alignment is done and completed using plumb and a water tube and bolted into beam. These curved panels have interlocking formation and are crimped together using mechanical seaming machine which imposed a load of approximately five tonnes to ensure the seaming of required rigidity. After seaming a clear epoxy lacquer is applied on the inner side of panel and concrete beam. Theses panel are installed over water proof concrete gutter beams having bevelled edge to receive support curved panels. Beam shall designed for arch reaction and vertical loads. Plaster shall not be applied on the beam. Schmitt hammer test of concrete should be carried before erection to ensure that the anchor bolt can be securely fixed on the support. In case of steel structure a steel runner plate of 6 mm thickness and GI sheet gutter of suitable size shall be provided for installation of panels, G.I. anchor bolt of required sizes and type with G.I. washer and neoprene asher shall be as design. After installation of panels, rapezoidal voids are created between gutterbeam and panels which should be covered by a flashing fabricated or brick masonry which is to be paid separately. Area of this roof shall be measured along the periphery on hemtop between end to end panels. Ridge and valley shall not taken in to consideration for measuring length transverse to periphery. The rate includes supplying, fixing, loading unloading, hire charges of all plants machineries, anchors, fasteners, washers, bolt, epoxy, paint and all wastage etc. complete. Accessories and fixtures like hangers clamp for installation of lighting fixtures utilityduct as per requirement and ventilators, skylight can also be provided at crownridge by making cuts into the panels which is to be paid separately. This
item shall be executed only by the agency which has all required manufacturing machineries and
necessary expertise. | Sqm | 2205.0 | 2205.0 | 5500.0 | False | None | None | False | None | False | 12127500.0 | 0 | 3850338 | 147063 | None | code17 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kgm3 and minimum compressive strength of 4.00 Nmm2 conforming to IS 2185 Part I 2005 and constructed with CM 14 as per IS 25722005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. CM SR 202324 P.No.17Vol26.32 | Sqm | 1375.5 | 1375.5 | 1411.8 | False | None | None | False | None | False | 1941930.9 | 0 | 3850339 | 147063 | None | code18 | Providing 18mm cement plaster in two coats under layer 12mm thick cement plaster with cement mortar 15 1 cement 5 coarse sand finished with atuoplayer 6mm thick cement plaster with cement mortar 16 1 cement 6 fine sand to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineerincharge. CM SR 202324 V2,P.No.42, I8.8 | Sqm | 389.55 | 389.55 | 3111.9 | False | None | None | False | None | False | 1212240.645 | 0 | 3850340 | 147063 | None | code19 | Finishing walls with Acrylic Smooth exterior paint of required shade New work Two coat applied 1.67L10 m² over and including priming coat of exterior primer applied 2.20 kg10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. CM SR 202324P.No.46Vol28.30 | Sqm | 182.7 | 182.7 | 3111.9 | False | None | None | False | None | False | 568544.13 | 0 | 3850341 | 147063 | None | code20 | Providing and fixing Steel work welded in built up sections framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin Charge. CM SR 202324P.No.84Vol211.25.2 | Kgs | 142.8 | 142.8 | 63060.85 | False | None | None | False | None | False | 9005089.38 | 0 | 3850342 | 147063 | None | code21 | Providing and fixing precoated galvanised iron profile sheetssize, shapeand pitch of corrugation as approved by Engineerincharge 0.50 mm 0.05 total coated thickness with zinc coating 120 gm2 asper IS 277,in 240 mpa steel grade, 57 microns epoxy primer on both side of the sheet and polyester top coat 1518 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerincharge. The sheet shall be fixed using self drillingself tapping screws ofsize 5.5x 55 mm with EPDM seal, complete upto any pitch in horizontal
vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. CM SR 202324P.No.26Vol27.38 | Sqm | 596.4 | 596.4 | 2096.85 | False | None | None | False | None | False | 1250561.34 | 0 | 3850343 | 147063 | None | code22 | Providing and fixing G.I. chain link fabric fencing of required width in mesh size 25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia wire or nuts, bolts and washers as required complete as per the direction of Engineerincharge.CM SR 202324P.No.96Vol2Item No. 11.60 | Sqm | 937.65 | 937.65 | 1140.0 | False | None | None | False | None | False | 1068921.0 | 0 | 3850344 | 147063 | None | code23 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sectionsappropriate sections and other sections of approved make conforming toIS 733 and IS1285, fixing with dash fasteners of required dia andsize, including necessary filling up the gaps at junctions, i.e. at top,bottom and sides with required EPDM rubber neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitred and jointedmechanically wherever required including cleat angle, Aluminium snap
beading for glazing paneling, C.P. brass stainless steelscrews, allcomplete as per architectural drawings and the directions of Engineerincharge. Glazing, paneling and dash fasteners to be paid for separatelyFor Fixed Portion Anodised aluminium anodised transparent or dyedto required shade according to IS 1868, Minimum anodic coating of grade AC 15 including cost of materials, labour, usage charges of machinery complete as per specifications. pwd SR 20232P.No. 87Vol2Item no 11.35.1.1 | Kgs | 474.6 | 474.6 | 240.0 | False | None | None | False | None | False | 113904.0 | 0 | 3850345 | 147063 | None | code24 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS 4454 part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge.
CM SR 202324P.No.78Vol211.6.1 | Sqm | 2764.65 | 2764.65 | 90.2304 | False | None | None | False | None | False | 249455.47536 | 0 | 3850346 | 147063 | None | code25 | Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the EngineerinCharge. CM SR 202324P.No.79Vol211.8.4 | Each | 25920.3 | 25920.3 | 4.0 | False | None | None | False | None | False | 103681.2 | 0 | 3850347 | 147063 | None | code26 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied 0.90L10 m² over an under coat of primer applied 0.80 L10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. CM SR 202324P.No.47Vol28.33.3 | Sqm | 145.95 | 145.95 | 274.4608 | False | None | None | False | None | False | 40057.55376 | 0 | 3850348 | 147063 | None | code27 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets core veneer hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 partI 1991. from manufacturer complete as per spcification. 30 mm thick both side commercial CM SR 202324P.No.105Vol212.57.3 | Sqm | 3155.25 | 3155.25 | 7.35 | False | None | None | False | None | False | 23191.0875 | 0 | 3850349 | 147063 | None | code28 | Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete. CM SR 202324P.No.105Vol212.61 | Each | 1039.5 | 1039.5 | 8.0 | False | None | None | False | None | False | 8316.0 | 0 | 3850350 | 147063 | None | code29 | Providing and fixing chromium plated brass handles of 100125 mm with necessary screws etc. complete CM SR 202324P.No.105Vol212.62 | Each | 248.85 | 248.85 | 4.0 | False | None | None | False | None | False | 995.4 | 0 | 3850351 | 147063 | None | code30 | Providing and fixing Aluminium Turbo ventilator complete as per technical specifications Non Power Driven with 0.9mm thickness and 38 No.s of Vanes turbine doom thickness 1mm and total weight not less than 5.2kg for Industrial use CM SR 202324P.No.38Vol27.69.1 | Each | 5481.0 | 5481.0 | 24.0 | False | None | None | False | None | False | 131544.0 | 0 | 3850352 | 147063 | None | code31 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sectionsappropriate sections and other sections of approved make conforming to IS 733 and IS1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing paneling, C.P. brass stainless steel screws, all complete as per architectural drawings and the directions of Engineerin charge. Glazing, paneling and dash fasteners to be paid for separately For Fixed Portion Powder coated aluminium minimum thickness of powder coating 50 micron including cost of materials, labour, usage charges of machinery complete as per specifications. CM SR 202324P.No.87Vol211.35.1.2 | Kgs | 513.45 | 513.45 | 250.0 | False | None | None | False | None | False | 128362.5 | 0 | 3850353 | 147063 | None | code32 | Earth work in surface excavation by mechanical means for lowering leveling the ground for all works other than foundation in all kinds of soils upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or
levelling the excavated earth or sorting stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including Cost of labour, tools, usage of machinery other appurtenances required to complete the work.CM SR 202324Vol11.12 for ROAD WORK | Cum | 99.75 | 99.75 | 416.0 | False | None | None | False | None | False | 41496.0 | 0 | 3850354 | 147063 | None | code33 | Construction of Subgrade and earthen Shoulders Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of table No. 3002 CM SR 202324Vol33.6 | Cum | 517.65 | 517.65 | 286.0 | False | None | None | False | None | False | 148047.9 | 0 | 3850355 | 147063 | None | code38 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works other parallel works from 0.50m to 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement formwork to be paid separately M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates CM SR 202324P.No.16Vol12.4.2 | Cum | 7303.07 | 7303.07 | 4.54 | False | None | None | False | None | False | 33155.9378 | 0 | 3850356 | 147063 | None | code39 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works other parallel works from 0.50m to 3.50 m height. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement formwork to be paid separately M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates CM SR 202324P.No.16Vol12.4.2 | Cum | 9958.73 | 9958.73 | 0.825 | False | None | None | False | None | False | 8215.95225 | 0 | 3850357 | 147063 | None | code41 | Finishing walls with water proofing cement paint of required shade New work Two coats applied 4.84 kg10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineerincharge. CM SR 202324P.No.45Vol28.28 | Sqm | 93.45 | 93.45 | 17.2 | False | None | None | False | None | False | 1607.34 | 0 | 3850358 | 147063 | None | code42 | Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergerss method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE 1 Additional rate on item 12 is allowed for drilling in over burden and fixing Casing pipes beyond 20M for fixing Casing pipes only a Above 20 M and upto 30 M 15,
b Above 30 M 30 Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level. 2 A sum of Rs. 100 is to be deducted for Dry
Borewell towards yield test. etc. complete. Vol5 SR 202324, Item no 12.4, P.No.140 | Each | 5552.4 | 5552.4 | 1.0 | False | None | None | False | None | False | 5552.4 | 0 | 3850359 | 147063 | None | code43 | Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost
of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc. for Above 300m of drilling add 10 for every 50m depth Vol5 SR 202324 I.No.12.2.1,12.2.2, P.No 139 0.00 to 50.00 Mtrs item no12.2.1 | Rmtr | 324.45 | 324.45 | 50.0 | False | None | None | False | None | False | 16222.5 | 0 | 3850360 | 147063 | None | code44 | Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportation of rig and supporting vehicles, crew charges, cost of consumables, cost
of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc. for Above 300m of drilling add 10 for every 50m depth Vol5 SR 202324 I.No.12.2.1,12.2.2, P.No 139 50.00 to 100.00 Mtrs item no 12.2.2 | Rmtr | 406.35 | 406.35 | 30.0 | False | None | None | False | None | False | 12190.5 | 0 | 3850361 | 147063 | None | code45 | PVC pipe OD 160mm and 6 Kgsqcm Vol5 SR 202324 , Sl.no 649, page no A44 for casing | Rmtr | 441.0 | 441.0 | 20.0 | False | None | None | False | None | False | 8820.0 | 0 | 3850362 | 147063 | None | code46 | Providing, Single Phase Submersible Pump Sets of 100mm dia 4 inch suitable for bore well confirming to IS 80342000 specifications, to work site with testing of as per instructions of engineer incharge of work andand latest amendments. 1.00 HP0.75KW, 12 STG Vol5 SR 202324 , page no 149 , i no 13.8.3 2.00 HP1.5KW 12 STG | Each | 18498.9 | 18498.9 | 1.0 | False | None | None | False | None | False | 18498.9 | 0 | 3850363 | 147063 | None | code47 | Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core sheathed of nominal cross sectional area as per IS 6941990 with ISI Mark and as per its latest amendmentsSR 202324, Vol5, It.No 13.22.2 P.No.154 1x3x2.5 Sqm | Sqm | 89.25 | 89.25 | 85.0 | False | None | None | False | None | False | 7586.25 | 0 | 3850364 | 147063 | None | code48 | Supply and delivery at site brand new best make starter control panel suitable for following HP centrifugal pump confirming with ISI mark and its latest amendments.. Vol5 SR 202324 CHAPTER 15, item No.13.43.1 P.No.157 , Upto 7.5 HP centrifugal pump | Each | 9975.0 | 9975.0 | 1.0 | False | None | None | False | None | False | 9975.0 | 0 | 3850365 | 147063 | None | code49 | Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work. Vol5 SR 202324 , item No.13.34, , P.No.156, | Job | 1522.5 | 1522.5 | 1.0 | False | None | None | False | None | False | 1522.5 | 0 | 3850366 | 147063 | None | code50 | Supply and delivery at site best indigenous brand new power capacitor as per IS 28341986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets. Vol5 SR 202324 , , item No.13.25, P.No.155 | Kvar | 577.5 | 577.5 | 1.0 | False | None | None | False | None | False | 577.5 | 0 | 3850367 | 147063 | None | code51 | Supply and delivery at site delivery of best indigenous brand new MCB Miniature Circuit Breakers of required capacity as per IS 882281978 and its latest amendments and with ISI Mark of 61016202540 Amps with scalable box. Vol5 SR 202324 , item No.13.26, P.No.155 | Per 3 Poles | 1207.5 | 1207.5 | 1.0 | False | None | None | False | None | False | 1207.5 | 0 | 3850368 | 147063 | None | code52 | Providing main connection from pole PVC insulated sheathed steel wire cable in new trench as per IS 1554 1988 with latest amendments with ISI mark from KPTCL pole to meter board unit. Vol5 SR 202324 , item No.13.36, P.No.156 | Rmtr | 141.75 | 141.75 | 15.0 | False | None | None | False | None | False | 2126.25 | 0 | 3850369 | 147063 | None | code53 | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 49842016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete Contractor will make his own arrangements for procuring water for testing etc. complete.. Vol5 SR 202324 , item No.9.1.1, 9.1.3 P.No.95 | Rmtr | 198.45 | 198.45 | 100.0 | False | None | None | False | None | False | 19845.0 | 0 | 3850370 | 147063 | None | code54 | Earthing Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.Vol5 SR 202324, , item No.13.39 P.No.157 | Job | 3937.5 | 3937.5 | 1.0 | False | None | None | False | None | False | 3937.5 | 0 | 3850371 | 147063 | None | code55 | Providing and fixing brass bib cock of approved quality 20 mm nominal bore Vol2 SR 202324, , item No.13.2.2 P.No.117 | Job | 320.25 | 320.25 | 1.0 | False | None | None | False | None | False | 320.25 | 0 | 3850372 | 147063 | None | code57 | Fabricating supplying and mounting MS box made out … SWG suitable for floor wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 14SWG PWD Ele Common SR Vol 6 ,202324 Page No20 It.No5.42.1 | Sq CM | 0.53 | 0.53 | 247000.0 | False | None | None | False | None | False | 130910.0 | 0 | 3850373 | 147063 | None | code58 | Supplying and fixing Moulded Case Circuit Breaker MCCB over the existing woodpanel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS13947. Icu100 lcs. In 4P MCCB, all Poles should have protection for ShortCicrcuitOver Load. For Microprocessor MCCBS Facility for segregating Priority and NonPriority loads must be available in the MCCB. MCCB shall be provided with double insulation insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open. Multipole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. FOUR Pole 400500 A 50 kA PWD Ele Common SR Vol 6, 202324 Page No16 It.No5.14.14 | Each | 43571.85 | 43571.85 | 1.0 | False | None | None | False | None | False | 43571.85 | 0 | 3850374 | 147063 | None | code59 | Supplying A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolicFRPDMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 400 A 4 x 50 x 10 mm Aluminium Strips PWD Ele Common SR Vol 6, 202324 Page No20 It.No5.40.3 | Rmtr | 4667.25 | 4667.25 | 35.0 | False | None | None | False | None | False | 163353.75 | 0 | 3850375 | 147063 | None | code60 | Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, powerfactor ,kVA, kWH, kVAR suitable for 3phase,4 wire LT network with IP54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracy As per Specification in Common PWD Common Electrical SR Vol6,202324 Page No19 Item No5.33 | Each | 9780.75 | 9780.75 | 1.0 | False | None | None | False | None | False | 9780.75 | 0 | 3850376 | 147063 | None | code61 | Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 230440VAC. 50 Hz 1224V D.C.PWD Ele Common Vol 6,SR 202324 Page No19 It.No5.38 | Each | 540.75 | 540.75 | 10.0 | False | None | None | False | None | False | 5407.5 | 0 | 3850377 | 147063 | None | code62 | Supplying, fixing and wiring 505 to 4005A 5VA burden CurrentTransformer Class 0.5 accuracy with Tape Wound. PWD Ele Common Vol 6,SR 202324 Page No19 It.No5.34 | Each | 590.1 | 590.1 | 6.0 | False | None | None | False | None | False | 3540.6 | 0 | 3850378 | 147063 | None | code63 | Supplying and fixing angle iron frame work fabricated out of M.S. angle iron.. and M.S. Flat......with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint.50 x 100 x 50 x 6 mm C channel PWD Ele Common SR Vol6,202324 Page No20 It.No5.41.4 | Rmtr | 793.8 | 793.8 | 50.0 | False | None | None | False | None | False | 39690.0 | 0 | 3850379 | 147063 | None | code64 | Supplying of Switch disconnector fuse unit TPN HRC type but without HRC fuses. With AC23A duty and as per IS 13947.l PWD Ele Common SR Vol6 202324 Page No15 250 A Page No15 It.No5.8.6 | Each | 10445.4 | 10445.4 | 2.0 | False | None | None | False | None | False | 20890.8 | 0 | 3850380 | 147063 | None | code65 | Supplying of Switch disconnector fuse unit TPN HRC type but without HRC fuses. With AC23A duty and as per IS 13947.l PWD Ele Common SR Vol6 202324 Page No15 100 A Page No15 It.No5.8.2 | Each | 4728.15 | 4728.15 | 2.0 | False | None | None | False | None | False | 9456.3 | 0 | 3850381 | 147063 | None | code66 | Supplying of Switch disconnector fuse unit TPN HRC type but without HRC fuses. With AC23A duty and as per IS 13947.l PWD Ele Common SR Vol6 202324 Page No15 63 A Page No15 It.No5.8.1 | Each | 2427.6 | 2427.6 | 8.0 | False | None | None | False | None | False | 19420.8 | 0 | 3850382 | 147063 | None | code67 | Supplying and fixing HRC fuse units base on existing switch panel board. PWD Ele Common SR 202324 Page No15 It.No 100 to 300 A Page No15 It.No5.9.3 | Each | 964.95 | 964.95 | 4.0 | False | None | None | False | None | False | 3859.8 | 0 | 3850383 | 147063 | None | code68 | Supplying and fixing HRC fuse units base on existing switch panel board. PWD Ele Common SR 202324 Page No15 It.No 32 to 63 A Page No15 It.No5.9.2 | Each | 642.6 | 642.6 | 8.0 | False | None | None | False | None | False | 5140.8 | 0 | 3850384 | 147063 | None | code69 | Supplying and fixing HRC fuse link on existing switch fuse base with W loss as per IS13703. PWD Ele Common SR 202324 Above 200 A to 315 A Page No15 It.No5.10.3 | Each | 705.6 | 705.6 | 8.0 | False | None | None | False | None | False | 5644.8 | 0 | 3850385 | 147063 | None | code70 | Supplying and fixing HRC fuse link on existing switch fuse base with W loss as per IS13703. PWD Ele Common SR 202324 Above 63 A to 200 A Page No15 It.No5.10.2 | Each | 400.05 | 400.05 | 8.0 | False | None | None | False | None | False | 3200.4 | 0 | 3850386 | 147063 | None | code71 | Four Core 25 Sq mm Copper cable with glandslugsferrules KPTCL Ele Common SR 202324 Page No40 It.No13.11 | Rmtr | 909.3 | 909.3 | 60.0 | False | None | None | False | None | False | 54558.0 | 0 | 3850387 | 147063 | None | code72 | Open Conduit System Supplying heavy gauge PVC Conduit pipe 25 mm dia 2mm thick with suitable bends, metalPVC junction box, adhesive paste etc.by Groove Cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever r necessary. As per Specification in Common PWD Common Electrical SR Vol6,202324 Page No2 Item No1.3.2
2520mm dia 2mm thick | Rmtr | 82.95 | 82.95 | 500.0 | False | None | None | False | None | False | 41475.0 | 0 | 3850388 | 147063 | None | code73 | Wiring for lightingpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694confirming to latest amendments.PWD Ele Common Vol 6,SR 202324 Page No5 It.No 1.5 Sqmm P.no 05, I.no 2.3.2 | Rmtr | 27.3 | 27.3 | 360.0 | False | None | None | False | None | False | 9828.0 | 0 | 3850389 | 147063 | None | code74 | Wiring for lightingpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694confirming to latest amendments.PWD Ele Common Vol 6,SR 202324 Page No5 It.No 2.5 Sqmm P.no 05, I.no 2.3.3 | Rmtr | 44.1 | 44.1 | 600.0 | False | None | None | False | None | False | 26460.0 | 0 | 3850390 | 147063 | None | code75 | Wiring for lightingpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694confirming to latest amendments.PWD Ele Common Vol 6,SR 202324 Page No5 It.No 4 mm2 Sqmm P.no 06, I.no 2.3.4 | Rmtr | 66.15 | 66.15 | 600.0 | False | None | None | False | None | False | 39690.0 | 0 | 3850391 | 147063 | None | code76 | Wiring for lightingpower circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694confirming to latest amendments.PWD Ele Common Vol 6,SR 202324 Page No5 It.No 16 mm2 Sqmm P.no 06, I.no 2.3.7 | Rmtr | 333.9 | 333.9 | 200.0 | False | None | None | False | None | False | 66780.0 | 0 | 3850392 | 147063 | None | code77 | Supplying and fixing surfaceflush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in BrickC.C wall, including necessary rawl
plugs, MachineNF screws etc., complete..As per Specification in Common PWD Electrical SR 202122PWD Ele Common SR Vol6 202324 6 Module P.no 08, I.no.3.3.3 | Each | 143.85 | 143.85 | 15.0 | False | None | None | False | None | False | 2157.75 | 0 | 3850393 | 147063 | None | code78 | Supplying and fixing surfaceflush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in BrickC.C wall, including necessary rawl
plugs, MachineNF screws etc., complete..As per Specification in Common PWD Electrical SR 202122PWD Ele Common SR Vol6 202324 18 Module P.no 03, I.no.3.3.8 | Each | 355.95 | 355.95 | 20.0 | False | None | None | False | None | False | 7119.0 | 0 | 3850394 | 147063 | None | code79 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalPVC box. Common PWD Electrical SR Vol 6,202324 6 Module P.no 08, I.no.3.5.4 | Each | 245.7 | 245.7 | 15.0 | False | None | None | False | None | False | 3685.5 | 0 | 3850395 | 147063 | None | code80 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metalPVC box. Common PWD Electrical SR Vol 6,202324 18 Module P.no 03, I.no.3.5.8 | Each | 479.85 | 479.85 | 20.0 | False | None | None | False | None | False | 9597.0 | 0 | 3850396 | 147063 | None | code81 | Supplyingandfixingofmodularswitchconnectedaccessoriesonexisting modular switch plate as per IS 3854 and IS 1293. Common PWD Electrical SR Vol 6,202324 6 Amps One way SwitchP.no.9. I.no 3.6.1 | Each | 107.1 | 107.1 | 120.0 | False | None | None | False | None | False | 12852.0 | 0 | 3850397 | 147063 | None | code82 | Supplyingandfixingofmodularswitchconnectedaccessoriesonexisting modular switch plate as per IS 3854 and IS 1293. Common PWD Electrical SR Vol 6,202324 616Amps universal socketP.no.5. I.no 3.6.10 | Each | 247.8 | 247.8 | 80.0 | False | None | None | False | None | False | 19824.0 | 0 | 3850398 | 147063 | None | code83 | Supplying and fixing of Metal Socket set of 2 pole and earth plugs and socket for incorporating SP and TP MCBWithout MCB.The entire plug and socket shall be mounted in a thermoplasticpowder coated metal box wired Completely. P.no21, I.no5.45.4 TP N 30 A | Each | 1785.0 | 1785.0 | 10.0 | False | None | None | False | None | False | 17850.0 | 0 | 3850399 | 147063 | None | code84 | Supplying fixing of Surface mounting type retrofit typeLED tube.......W comprising of LED linear source with CCT 6500 degree K, CRI70. efficacy80 lumenperW, life25000 burning hours and Compliance to IS10322IEC60598, LM79 LM80.The LED are driven by HF electronic driver integrated inthe system, with PF0.95, power loss should5 of lamp Wage.,shortcircuit opencircuit protection to be integrated in the circuit, THD less than 20,Life as per LM79.The operating input voltage should be between 130 to 275V. BIS Approved and Tested byNABLCPRI accredited laboratory with 2years Warranty against any manufacturing defect working under standard electrical condition..PolycarbonateOPAL Acrylic Casing 18W20W T8 P.no47, I.no11.10.5 | Each | 717.15 | 717.15 | 25.0 | False | None | None | False | None | False | 17928.75 | 0 | 3850400 | 147063 | None | code85 | Supplying capacitor type ceiling fan complete with downrod blades, shackle, canopiesetc, for operation on 230V, 50cycles. Single phase AC supply conforming to ISS3741979 and with double ball bearing system.. supply. Common SR Electrical PWD Rates 202324 Vol6 P No57, Sl No6.3.1 48 Sweep 1200 mm Regular model P.no30, I.no6.31 | Each | 3133.2 | 3133.2 | 8.0 | False | None | None | False | None | False | 25065.6 | 0 | 3850401 | 147063 | None | code86 | Supplying and fixing regular MCB distribution boards on wall wood board flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCBs single phase 3 phase single door with powder coated painting. Made out of 14 SWG MS enclosure.As per Specification in Common PWD Electrical SR Vol6, 202324 Page No13 Item No5.19.5 16 Way SP N | Each | 3078.6 | 3078.6 | 4.0 | False | None | None | False | None | False | 12314.4 | 0 | 3850402 | 147063 | None | code87 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve, indicator ONOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. As per Specification in Common PWD Electrical SR Vol6, 202324 632 Amps DP P.no 13, I.no.5.18.4 | Each | 775.95 | 775.95 | 30.0 | False | None | None | False | None | False | 23278.5 | 0 | 3850403 | 147063 | None | code88 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 Part1 or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975 240 Sqmm, 3.5 Core, 30 GI Strips 4 x 0.8 mm ESCOM Common SR Vol6 202324 P.No 13 I no32.18 | Rmtr | 905.79 | 905.79 | 250.0 | False | None | None | False | None | False | 226447.5 | 0 | 3850404 | 147063 | None | code89 | RCC Hume Pipe 2000 mm long 200 mm Dia ESCOM Common SR Vol6,202324 P.No 23 I no68.02 | Each | 409.5 | 409.5 | 25.0 | False | None | None | False | None | False | 10237.5 | 0 | 3850405 | 147063 | None | code90 | Labour Collars for fixing RCC Hume Pipe 200 mm Dia ESCOM Common SR Vol6,202324 P.No 23 I no68.04 | Each | 108.15 | 108.15 | 25.0 | False | None | None | False | None | False | 2703.75 | 0 | 3850406 | 147063 | None | code91 | Laying of cable in Existing TrenchGI pipeStone WareRCC Hume pipe using WoodenAluminum Rollers as directed by the departmental staff 120 to 240 Sqmm ESCOM Common SR Vol 6 ,202324 P.No 9 I no21.07 | Rmtr | 33.88 | 33.88 | 250.0 | False | None | None | False | None | False | 8470.0 | 0 | 3850407 | 147063 | None | code92 | Earth work excavation for pipelinescables by Manual means upto 600mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth excluding rock in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage other appurtenances required to complete the work. In all kinds of soils. Depth upto 1.50m As per PWD Common Civil SR 202324 Page No6 Item No1.6 | Cum | 508.2 | 508.2 | 169.75 | False | None | None | False | None | False | 86266.95 | 0 | 3850408 | 147063 | None | code93 | Supply of LED Streetlight luminaire with pressure die cast aluminum housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare Diffuser with Injection moulded polycarbonate materail,delivering superior light output. Rated life Burning Hrs 50000 hr Lumen Maintenance of 70. maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment impact resistance of complete luminare IK08. Power Factor 0.9 with mains Current should not be greater than 0.1A to 0.7A Surge Protection Min 4KV along with Over voltageOverload, short circuit miswiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 5060Hz application. Over load Short circuit protection ensures reliable operation in spite of problem in output side. Compliance to IS 10322IEC 60598, LM 79 LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with 40W System Power consumption. LED Efficiency130lmw at 1W Fixture Efficiency 80lmw with nominal CRI 75. Luminaire manufacturer should have inhouse facility accredited by NABLCPRI any Government certified agency Design Development facility certified by ISO 90012008 . Housing with supplier word mark name shall be Engraved Embossing on the die cast housing Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED source manufacture. CreeNichia lumileds osram make LED source.PWD Electrical Common SR Vol6,202324 LED street light 40W LED Streetlight 70W Page No46 Sl .No11.8.3 | Each | 6291.6 | 6291.6 | 14.0 | False | None | None | False | None | False | 88082.4 | 0 | 3850409 | 147063 | None | code94 | LT 4 Pin Cross Arm MS Dwg No. BESCOMGMQSS32 Dtd 24.11.2018 ESCOM SR Vol 6,202324 P4 Item No2.05 | Each | 303.45 | 303.45 | 10.0 | False | None | None | False | None | False | 3034.5 | 0 | 3850410 | 147063 | None | code95 | LabourFixing of 4 Pin cross arm with Insulator and Braces fixing ESCOM SR Vol 6,202324 Page No45, Item No5.02 | Each | 168.0 | 168.0 | 10.0 | False | None | None | False | None | False | 1680.0 | 0 | 3850411 | 147063 | None | code96 | Earthing Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts, nuts, washers and check nuts, the pipe shall have 16 through holes of 12mm dia.. .BWSSB SR 202324 Vol 6 P.No157 Item no13.39 | Each | 3937.5 | 3937.5 | 15.0 | False | None | None | False | None | False | 59062.5 | 0 | 3850412 | 147063 | None | code97 | Fabricating, supplying and erection of …Mtrs long hot dip Galvanized Octagonal pole with BSEN 10025 grade S 355 JO steel plate for shaft, IS 2062 for base plate with door opening arrangements, including suitable boards, bakelite sheet and MCBs as per IS specifications suitable to withstand the wind speed of 47msec for …….Mtrs pole in single section and single joint welded as per IS 9595IS 10178AWS having dimensions bottom …..mm, top….mm with 3mm thick, suitable base plate and 4Nos of ..... long J bolts along with tem plate and the pole shall be galvanized in single dipping with not less than 65micron as per ASTMA123 and 153etc., Excluding foundation as oer drawing appended. 9 m Top 70 mm and Bottom 155 mm dia Common PWD Ele common Vol6 202324 P.11 Item no 4.2.7 | Each | 20475.0 | 20475.0 | 14.0 | False | None | None | False | None | False | 286650.0 | 0 | 3850413 | 147063 | None | code98 | Supply of LED Floodlight luminaire with pressure die cast aluminum housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare Diffuser with Injection moulded polycarbonate materail,delivering superior light output. Rated life Burning Hrs 50000 hr Lumen Maintenance of 70. maximum light intensity should be between 60 degrees to 70 degrees. CCT 5500K, IP 66 optical and electrical compartment impact resistance of complete luminare IK08. Power Factor 0.9 with mains Current should not be greater than 0.1A to 0.7A Surge Protection Min 4KV along with Over voltageOverload, short circuit miswiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 5060Hz application. Over load Short circuit protection ensures reliable operation in spite of problem in output side. Compliance to IS 10322IEC 60598, LM 79 LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with System Power consumption. LED Efficiency130lmw at 1W Fixture Efficiency 80lmw with nominal CRI 75. Luminaire manufacturer should have inhouse facility accredited by NABLCPRI any Government certified agency Design Development facility certified by ISO 90012008 . Housing with supplier word mark name shall be Engraved Embossing on the die cast housing Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED source manufacture. CreeNichialumiledsosram make LED source. PWD LED Floodlight 120W Common PWD Ele 202324 P.46 Item no11.9.3 Outside area 25 Nos and inside Pre sorting and post sorting shed 35 Nos | Each | 11294.85 | 11294.85 | 60.0 | False | None | None | False | None | False | 677691.0 | 0 | 3850414 | 147063 | None | code99 | Supplying, and fixing of Hot dip Galvanize M.S.Bracket suitable for outdoor luminaries and mounted on Octagonal pole using necessary bolts, nuts etc., complete.ESCOM Common SR Vol6, 202324P.No 13 I no4.6.1 Single Arm Bracket with 1000 mm Standard 4050 mm dia | Rmtr | 1785.0 | 1785.0 | 14.0 | False | None | None | False | None | False | 24990.0 | 0 | 3850415 | 147063 | None | code100 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS1554 Part1 or IS7098 Part1, Armouring strip thickness and resistivity as per IS3975 16 Sqmm, 4 Core, 11 GI Strips 4 x 0.8 mm ESCOM Common SR Vol6, 202324P.No 13 I no32.05 | Rmtr | 148.93 | 148.93 | 700.0 | False | None | None | False | None | False | 104251.0 | 0 | 3850416 | 147063 | None | code101 | Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS81301984 and Virgin PVC insulation and sheathed suitable for working voltage upto 1100Volts as per IS6941990 p, no6 I no2.5.7 PWD Ele Common SR Vol6 202324 | Rmtr | 86.1 | 86.1 | 350.0 | False | None | None | False | None | False | 30135.0 | 0 | 3850417 | 147063 | None | code102 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C curve , indicator ONOFF, energy cross3 with Short circuit breaking capacity of 10K and complete wiring as required Confirming to IEC 60898 PWD Ele Common SR Vol6 202324 a 5063Amps TPN P.No13 I no, 5.18.9 | Each | 3242.4 | 3242.4 | 10.0 | False | None | None | False | None | False | 32424.0 | 0 | 3850418 | 147063 | None | code103 | Supplying heavy gauge PVC conduit pipe …….dia........mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall stone structure or rawl plugs in case of brick walls and cement plastering damaged portion using heavy gauge saddles at an interval of 700mm using NF screws PWD Ele Common SR Vol6 202324P.No 2 I.no, 1.1.4 40 mm dia 2.5mm thick | Rmtr | 156.45 | 156.45 | 300.0 | False | None | None | False | None | False | 46935.0 | 0 | 3850419 | 147063 | None | code104 | Laying of cable in Existing TrenchGI pipeStone WareRCC Hume pipe using WoodenAluminum Rollers as directed by the departmental staff 2.5 to 25 Sqmm ESCOM Common SR Vol6 202324 P.No 52 I no31.05 | Rmtr | 21.92 | 21.92 | 700.0 | False | None | None | False | None | False | 15344.0 | 0 | 3850420 | 147063 | None | code105 | Supply and Installation Fixing Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 Weather Proof, rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase Three Phase Energy Meter in suitable base plate and having a provision for Fuse MCB cutout with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.PWD Ele Common SR Vol6 202324 p, no21 I no, 5.44.4 600x600x170mm | Each | 15246.0 | 15246.0 | 2.0 | False | None | None | False | None | False | 30492.0 | 0 | 3850421 | 147063 | None | code106 | Providing, Laying and Fixing of GI pipes conforming to IS 12391990 with latest amendments complete with GI fittings excluding the cost of fittings with cuts and threads wherever necessary, including testing for water tightness, with all lead and commissioning. contractor will make his own arrangements for procuring water for testing Medium Duty GI pipe of 100mm dia etc. complete. Item No11.2.9 Page no127 of ESCOM Common SR Vol6 202324 | Rmtr | 1307.25 | 1307.25 | 25.0 | False | None | None | False | None | False | 32681.25 | 0 | 3850422 | 147063 | None | code107 | Supplying Laying cable trays including welding, fixing of supports. complete. Cable tray of 300 mm width suitable for cable duct of D type Item No 22.a.ii. Page no120 of KPTCL Common SR Vol6 202324 | Rmtr | 791.7 | 791.7 | 200.0 | False | None | None | False | None | False | 158340.0 | 0 | 3850423 | 147063 | None | code108 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including Depth exceeding 1.5m, but not exceeding 3 mAs per PWD Common Civil SR 202324 Page No5 Item No1.4.2 | Cum | 271.95 | 271.95 | 28.0 | False | None | None | False | None | False | 7614.6 | 0 | 3850424 | 147063 | None | code109 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement formwork shall be paid separately Mix 148 Using 40 mm nominal size graded crushed coarse aggregates PWD Common Civil SR 202324 Page No15 Item No2.1.2 | Cum | 5947.2 | 5947.2 | 1.68 | False | None | None | False | None | False | 9991.296 | 0 | 3850425 | 147063 | None | code110 | Supplying, fitting and placing TMT FE 550 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, lapingwelding joints, tying with binding wire soft annealed steel wire and other ancilary operations complete as per drawing and technical specification PWD Road Bridge PWD Common SR 202324 Vol 1 Page No18 Item No2.11h All other type of structures | Tonne | 88602.15 | 88602.15 | 0.2866 | False | None | None | False | None | False | 25393.37619 | 0 | 3850426 | 147063 | None | code111 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granitetrapbasalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. The cost of steel reinforcement formwork to be paid separately PWD Common Civil SR 202122 Page No15 Item No2.2.1.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6542.55 | 6542.55 | 17.024 | False | None | None | False | None | False | 111380.3712 | 0 |
|