1725629148000 | 0 | None | None | Buildings | Construction of Toilet to Taluk Community Health Center in Rattihalli TP Limit | 126857.17 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3938209 | 152219 | None | code01 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. PWD SR 2023-24 (Vol-1, Page No 5, I No 1.4.1) | Cum | 249.26 | 249.26 | 5.69 | False | None | None | False | None | False | 1418.2894 | 0 | 3938210 | 152219 | None | code02 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.(Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates) PWD CM-SR(Vol-1, Page No 15, I No 2.1.3) | Cum | 6168.67 | 6168.67 | 1.14 | False | None | None | False | None | False | 7032.2838 | 0 | 3938211 | 152219 | None | code03 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite /trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications (M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates) PWD SR 2023-24(Vol-1, Page No 16, I No 2.4.2) | Cum | 8792.13 | 8792.13 | 2.1 | False | None | None | False | None | False | 18463.473 | 0 | 3938212 | 152219 | None | code04 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. Thecost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specification. (M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates) PWD SR 2023-24(Vol-1, Page No 16, I No 2.5.1) | Cum | 9219.02 | 9219.02 | 0.79 | False | None | None | False | None | False | 7283.0258 | 0 | 3938213 | 152219 | None | code05 | Providing and laying in position Ready Mixed or Batch Mixed concrete from ISO 9001 accredited plants as per IS 10262-2009 mix design procedure for Reinforced
Cement Concrete works in all types of Structures other than Road works, using coarse aggregate and fine aggregate derived from natural sources, Ordinary
Portland cement & GGBS, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering,shuttering, finishing and reinforcement as per direction of the Engineer-in-charge (D VOL-1.11 Supplying, fitting and placing TMT FE 550/550D Steel Reinforcement complete as per drawing and technical specification.) KPWD VOL-1 (TMT bars including 5 per cent overlaps and wastage) PWD SR 2023-24(Vol-1, Page No 19, I No 2.11) | Tonne | 89025.99 | 89025.99 | 0.0632 | False | None | None | False | None | False | 5626.442568 | 0 | 3938214 | 152219 | None | code06 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work (PWD SR 2023-24(Vol-II, Page No 13, I No 6.2) | Cum | 8217.34 | 8217.34 | 2.26 | False | None | None | False | None | False | 18571.1884 | 0 | 3938215 | 152219 | None | code07 | 14.3 Providing and fixing white vitreous china pedestal type water closet
(European type) with seat and lid, 10 litre low level white vitreous china
flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush
bend, overflow arrangement with specials of standard make and mosquito
proof coupling of approved municipal design complete, including
painting of fittings and brackets, cutting and making good the walls and
floors wherever required : (PWD SR 2023-24(Vol-II, Page No 131, I No 14.3.1) | Each | 6156.31 | 6156.31 | 1.0 | False | None | None | False | None | False | 6156.31 | 0 | 3938216 | 152219 | None | code08 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.(Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates) PWD CM-SR(Vol-1, Page No 15, I No 2.1.4) | Cum | 6403.51 | 6403.51 | 0.98 | False | None | None | False | None | False | 6275.4398 | 0 | 3938217 | 152219 | None | code09 | Providing 20 mm cement plaster of mix :1:6 (1 cement: 6 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge(PWD CM-SR(Vol-II, Page No 41, I No 8.3.2) | Sqm | 342.99 | 342.99 | 20.66 | False | None | None | False | None | False | 7086.1734 | 0 | 3938218 | 152219 | None | code10 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622,of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete (Size of Tile 600x600 mm)(PWD CM-SR(Vol-II, Page No 61, I No 9.17.2) | Sqm | 1210.25 | 1210.25 | 5.76 | False | None | None | False | None | False | 6971.04 | 0 | 3938219 | 152219 | None | code11 | SOLID PVC DOOR FRAME: Providing & fixing factory made PVC Door frame of size 50 x 47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge(PWD CM-SR(Vol-II, Page No 104, I No 12.54) | Sqm | 327.54 | 327.54 | 1.35 | False | None | None | False | None | False | 442.179 | 0 | 3938220 | 152219 | None | code12 | SOLID PVC DOOR SHUTTER :Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges (PWD CM-SR (Vol-II, Page No 104, I No 12.53 | Sqm | 1635.64 | 1635.64 | 1.62 | False | None | None | False | None | False | 2649.7368 | 0 | 3938221 | 152219 | None | code13 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineerin-Charge. ( PWD CM-SR 2023-24 2023-24 (Vol-2, Page No 82, I No 11.16.2) | Kg | 151.41 | 151.41 | 77.0 | False | None | None | False | None | False | 11658.57 | 0 | 3938222 | 152219 | None | code14 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge ( PWD CM-SR 2023-24 2023-24 (Vol-2, Page No 45, II No 8.25) | Sqm | 141.11 | 141.11 | 20.16 | False | None | None | False | None | False | 2844.7776 | 0 | 3938223 | 152219 | None | code15 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper
smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-chege ( PWD CM-SR 2023-24 2023-24 (Vol-2, Page No 45, II No 8.28) | Sqm | 91.67 | 91.67 | 47.71 | False | None | None | False | None | False | 4373.5757 | 0 | 3938224 | 152219 | None | code16 | Supplying & erection of RCC rings for well steining of 0.3mtr Depth using M-20 grade cocrete using clean graded granite or trap or jelly of approved quality 20mm and dow size well compacted including centering, form work and plstering for both faces with C.M 1:3 proportion as per design using 6.50mm M S coil at the rate of 10 kg/ringincuding cost of steel and fabrication, bailing out of water, errection etc.. complete for the 1.20m dia (clear) rings of steining thickness 0.075mm up to 18M depth | Each | 1181.41 | 1181.41 | 8.0 | False | None | None | False | None | False | 9451.28 | 0 | 3938225 | 152219 | None | code17 | Providing and placing on terrace, polyethelene water storage tanks with manhole lid and suitable locking arragements, making holes of suitable diameter for inlet outlet and over flow pipes including cost of all materials, labour, transport charges HOM of equipments and testing complete as per specifications (1000 liter capacity) | Each | 7554.02 | 7554.02 | 1.0 | False | None | None | False | None | False | 7554.02 | 0 | 3938226 | 152219 | None | code18 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. ( PWD CM-SR 2023-24 2023-24 (Vol-2, Page No 122, II No 13.31.1) | Each | 187.46 | 187.46 | 16.0 | False | None | None | False | None | False | 2999.36 | 0 |
|