tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1725628168000 | 0 | None | None | Buildings | CONSTRUCTION OF CLASS ROOM TO GOVT. HRPS (URDU) AT ZAMISTANPUR-1, GOVT. HRPS (URDU) KADWAD-1 & GOVT. HRPS (URDU) AT MANHALLI-1 IN BIDAR TALUKA | 3339612.16 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3938141 | 152216 | None | 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling
the ground for all works other than foundation in all kinds of soils & upto depth
not exceeding 300mm as per drawing and technical specifications, including
setting out, shoring, strutting, barricading, caution lights, removal of stumps
and other deleterious matter including dressing of excavated surfaces, disposing
off or levelling the excavated earth or sorting & stacking the selected earth for
reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools,
usage of machinery & other appurtenances required to complete the work.
In all kinds of soils upto 300 mm depth | Cum | 99.75 | 99.75 | 32.4 | False | None | None | False | None | False | 3231.9 | 0 | 3938142 | 152216 | None | 1.15.1 | Earth work excavation for Foundation by mechanical means for all works &
depth upto 3 m, as per drawing and technical specifications, including setting
out, shoring, strutting, barricading, caution lights, including dressing of
excavated surfaces, disposing off or levelling the excavated earth or sorting
& stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5
m including cost of labour, tools, usage of machinery & other appurtenaces
required to complete the work | Cum | 381.15 | 381.15 | 91.77 | False | None | None | False | None | False | 34978.1355 | 0 | 3938143 | 152216 | None | 2.1.2 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/ trap/ basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators,
including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 5947.2 | 5947.2 | 12.6 | False | None | None | False | None | False | 74934.72 | 0 | 3938144 | 152216 | None | 2.2.1 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates
as per relevant IS Codes machine mixed with super plasticizers laid in finished
layers, well compacted using needle vibrators, including all lead & lifts, cost
of all materials, quality confirming to the requirements of relevant IS codes,
labour, Usage charges of machinery, curing and all the other appurtenances
required to complete the work as per technical specifications.
2.2.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6601.35 | 6601.35 | 18.78 | False | None | None | False | None | False | 123973.353 | 0 | 3938145 | 152216 | None | 2.2.1 | Centering & Shuttering charfges for footing | Cum | 502.96 | 502.96 | 18.78 | False | None | None | False | None | False | 9445.5888 | 0 | 3938146 | 152216 | None | 2.4.2 | Providing and laying in position Cement Concrete for all Sub structures of
building, Irrigation works, Sub structure works of bridges, Drain works &
other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt
crushed graded coarse aggregates and fine aggregates as per relevant IS
Codes machine mixed with super plasticisers, laid in layers, well compacted
using needle vibrators, providing weep holes wherever necessary, including
all lead & lifts, cost of all materials of quality, confirming to the requirements
of relevant IS codes, labour, Usage charges of machinery, curing and all other
appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6639.15 | 6639.15 | 11.85 | False | None | None | False | None | False | 78673.9275 | 0 | 3938147 | 152216 | None | 2.4.2 | Centering & Shuttering charges for columns 70% | Cum | 4647.41 | 4647.41 | 4.32 | False | None | None | False | None | False | 20076.8112 | 0 | 3938148 | 152216 | None | 2.4.2 | Centering & Shuttering charges for plinth beams 50% | Cum | 3319.58 | 3319.58 | 7.53 | False | None | None | False | None | False | 24996.4374 | 0 | 3938149 | 152216 | None | 2.5.1 | Providing and laying in position Cement Concrete for all Super structures of
building , Road works, Water works, Irrigation works & super structure works
of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse
aggregates and fine aggregates as per relevant IS Codes machine mixed with
super plasticisers laid in layers, well compacted using needle vibrators. The
cost includes all lead & lifts, cost of all materials, quality confirming to the
requirements of relevant IS codes , labour, Usage charges of machinery, curing
and all other appurtenances required to complete the work as per technical
specifications.
2.5.1 M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6961.5 | 6961.5 | 44.28 | False | None | None | False | None | False | 308255.22 | 0 | 3938150 | 152216 | None | 2.5.1 | Centering & Shuttering charges for columns 70% | Cum | 4873.05 | 4873.05 | 7.62 | False | None | None | False | None | False | 37132.641 | 0 | 3938151 | 152216 | None | 2.5.1 | Centering & Shuttering chrges for Lintel & Beam 60% | Cum | 4176.9 | 4176.9 | 12.93 | False | None | None | False | None | False | 54007.317 | 0 | 3938152 | 152216 | None | 2.5.1 | Centering & Shuttering charges for Roof Slab 50% | Cum | 3480.75 | 3480.75 | 23.25 | False | None | None | False | None | False | 80927.4375 | 0 | 3938153 | 152216 | None | 2.5.1 | Centering & Shuttering charges for Chajja 45% | Cum | 3132.68 | 3132.68 | 0.48 | False | None | None | False | None | False | 1503.6864 | 0 | 3938154 | 152216 | None | 2.11 a | 2.11 Steel Fabrication
Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement
including cost of all materials, machinery, labour, cleaning, straightening,
cutting, bending, hooking, laping/welding joints, tying with binding wire / soft
annealed steel wire and other ancilary operations complete as per drawing and
technical specification.
a. Buildings | Tonne | 93929.85 | 93929.85 | 5.82 | False | None | None | False | None | False | 546671.727 | 0 | 3938155 | 152216 | None | 5.1.1 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : 5.1.1 Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 5891.55 | 5891.55 | 27.3 | False | None | None | False | None | False | 160839.315 | 0 | 3938156 | 152216 | None | 5.6 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification
I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Basement in CM 1:6. | Cum | 6770.4 | 6770.4 | 38.73 | False | None | None | False | None | False | 262217.592 | 0 | 3938157 | 152216 | None | 2.1.3 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes achine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 17.85 | False | None | None | False | None | False | 112248.8325 | 0 | 3938158 | 152216 | None | 1.11 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations
and other similar works etc. in layers not exceeding 20cm in depth, consolidating
each deposited layer by ramming and watering, lead up to 50 m and lift upto
1.5 m. | Cum | 454.65 | 454.65 | 146.13 | False | None | None | False | None | False | 66438.0045 | 0 | 3938159 | 152216 | None | 6.8 | Providing Brick work with common burnt clay Non Modular bricks of
class designation 3.5 in superstructure above plinth level in all shapes and
sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of
all materials, labour, scaffolding and usage charges of machinery & other
incidental charges complete as per the direction of engineer incharge of
work. | Cum | 8367.45 | 8367.45 | 38.91 | False | None | None | False | None | False | 325577.4795 | 0 | 3938160 | 152216 | None | 12.13.1 | Providing Salwood frames of doors, windows, clerestory windows,
ventilators and other frames, wrought, framed or assembled including
making plaster groves (excluding cost of cement concrete and side clamps),
but including cost of materials, labour, usage charges complete as per
specifications. | Cum | 103755.75 | 103755.75 | 0.9 | False | None | None | False | None | False | 93380.175 | 0 | 3938161 | 152216 | None | 12.51 | Fixing of door frame in an existing opening including embedding frame in
floor and walls after cutting masonry for holdfasts for embedding holdfast
in cement concrete 1:3:6 of 20mm and down size granite metal painting
two coats of coal tar to sides of frame, making good the damages to walls
and floor as required and disposal of the debris with lead upto 50 m.
including cost of materials, labour charges, complete as per specifications | No | 1066.8 | 1066.8 | 3.0 | False | None | None | False | None | False | 3200.4 | 0 | 3938162 | 152216 | None | 12.52 | Fixing of window frame in an existing opening including embedding frame
in floor and walls after cutting masonry for holdfasts for embedding
holdfast in cement concrete 1:3:6 of 20mm and down size granite metal
painting two coats of coal tar to sides of frame, making good the damages
to walls and floor as required and disposal of the debries with lead
upto 50 m. including cost of materials, labour charges, complete as per
specifications. | No | 811.65 | 811.65 | 9.0 | False | None | None | False | None | False | 7304.85 | 0 | 3938163 | 152216 | None | 12.21 | Providing and fixing in position fully panelled Matti/Nandi wood shutters
for doors with , stiles and rails of 30mm. thick with bottom and lock rails
180mm wide top rail and stiles 100mm wide as per drawing and panels
of 25mm thick including cost of materials, labour, usage charges complete
as per specifications. (excluding cost of fixtures) | Sqm | 6029.1 | 6029.1 | 6.3 | False | None | None | False | None | False | 37983.33 | 0 | 3938164 | 152216 | None | 12.32 | Providing and fixing in position Mathi / Nandi wood fully panelled shutters
for windows with stiles and rails of 25mm. thick, 75mm wide in two
halves with panels of 20mm thick including cost of materials, labour
charges, usage charges complete as per specifications. (excluding cost of
fixtures) | Sqm | 6134.1 | 6134.1 | 16.2 | False | None | None | False | None | False | 99372.42 | 0 | 3938165 | 152216 | None | 11.34B | Providing and fixing M.S. grills of required pattern in frames of windows
etc. with M.S. flats, square or round bars etc. including priming coat with
approved steel primer all complete. Fixed to openings /wooden frames
with rawl plugs screws etc. | Kg | 192.15 | 192.15 | 207.9 | False | None | None | False | None | False | 39947.985 | 0 | 3938166 | 152216 | None | 8.1.2 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement:
6 fine sand) including rounding off corners wherever required smooth
rendering, providing and removing scaffolding, including cost of materials,
labour, curing complete as per specifications and as per directions of
Engineer-in-charge | Sqm | 253.05 | 253.05 | 154.98 | False | None | None | False | None | False | 39217.689 | 0 | 3938167 | 152216 | None | 8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick
wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners
wherever required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications
and as per directions of Engineer-in-charge. | Sqm | 309.75 | 309.75 | 216.69 | False | None | None | False | None | False | 67119.7275 | 0 | 3938168 | 152216 | None | 8.51 | Providing and applying white cement based putty of average thickness
1 mm, of approved brand and manufacturer, over the plastered
wall surface to prepare the surface even and smooth complete as per
specifications and as per directions of Engineer in charge. | Sqm | 105.0 | 105.0 | 371.67 | False | None | None | False | None | False | 39025.35 | 0 | 3938169 | 152216 | None | 8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding,
including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 389.55 | 389.55 | 367.62 | False | None | None | False | None | False | 143206.371 | 0 | 3938170 | 152216 | None | 9.17.2 | Providing and laying Vitrified tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08 % and conforming to I.S. 15622,
of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete. Size of Tile 600x600 mm | Sqm | 1233.75 | 1233.75 | 161.88 | False | None | None | False | None | False | 199719.45 | 0 | 3938171 | 152216 | None | 8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including
water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 143.85 | 143.85 | 371.67 | False | None | None | False | None | False | 53464.7295 | 0 | 3938172 | 152216 | None | 8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade :New
work (Two coat applied @ 1.67L/10 m² over and including priming coat of
exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality
to give an even shade, after thoroughly brooming the surface to remove all
dirt, dust, mortar drops and foreign matter including preparing the surface
even and sand paper smooth, cost of materials, labour complete as per
specifications and as per directions of Engineer-in-charge. | Sqm | 182.7 | 182.7 | 367.62 | False | None | None | False | None | False | 67164.174 | 0 | 3938173 | 152216 | None | 8.33.2 | Painting wood work with Deluxe Multi Surface Paint of required shade.
Two coat applied @ 0.90L/10 m² over an under coat of primer applied
@0.75 L/10 m² of approved brand and manufacture to give an even shade
including preparing the surface after thorougly cleaning oil, grease, dirt
and foreign matter, sand papering and knotting , cost of materials, labour
complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 144.9 | 144.9 | 50.61 | False | None | None | False | None | False | 7333.389 | 0 | 3938174 | 152216 | None | 8.33.3 | Painting Steel work with Deluxe Multi Surface Paint to give an even
shade. Two coat applied @ 0.90L/10 m² over an under coat of primer
applied @ 0.80 L/10 m² of approved brand and manufacture including
preparing the surface after thorougly cleaning oil, grease, dirt and foreign
matter, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 145.95 | 145.95 | 32.4 | False | None | None | False | None | False | 4728.78 | 0 | 3938175 | 152216 | None | 11.26.1 | Providing and fixing hand rail of approved size by welding etc. to steel
ladder railing, balcony railing, staircase railing and similar works,
including applying priming coat of approved steel primer. M.S. tube
including cost of materials, labour, usage charges of machinery complete
as per specifications and as per directions of the Engineer-in-Charge. | Kg | 144.9 | 144.9 | 468.0 | False | None | None | False | None | False | 67813.2 | 0 | 3938176 | 152216 | None | Data rate | Providing and fixing green board paneeled 1mm thick metal sheet framed with aluminium channel section complete as per IS standards As per data rate Rs. 8500.00/No | No | 8500.0 | 8500.0 | 3.0 | False | None | None | False | None | False | 25500.0 | 0 | 3938177 | 152216 | None | KKRDB Logo | KKRDB Logo Board | No | 6000.0 | 6000.0 | 3.0 | False | None | None | False | None | False | 18000.0 | 0 |
| 1725628168000 | 0 | None | None | Buildings | ELECTRIFICATION WORK | 179127.9 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3938178 | 152217 | None | 1.2.1 | SupplyingheavygaugePVCconduitpipe.mmdia.mmthickconfirmingtoIS2509withsuitablesizebends,metal/PVCJunctionboxes,adhesivepasteetc.,andrunningbeforeconcretingtheslab.TheconduitshouldbetiedtothereinforcementrodsbyusingbindingwiresandunusedwaysofjunctionboxesandpipeendsshouldbecoveredusingPVCendenclosures,runwith18SWGGIfishwirewherever necessary
1.2.1 19/20 mm dia 2 mm thick | m | 69.3 | 69.3 | 180.0 | False | None | None | False | None | False | 12474.0 | 0 | 3938179 | 152217 | None | 1.3.1 | SupplyingheavygaugePVCConduitPipe.dia.mmthickwithsuitablesizebends,metaljunctionboxesadhesivepasteetc.,bygroovecuttinginthewallandfixingbybracingUorJhooksandcementplasteringuptothewallsurfaceandrunwith18SWGGIfishwire run throughout the conduit wherever necessary.
1.3.1
19/20 mm dia 2 mm thick | m | 71.4 | 71.4 | 120.0 | False | None | None | False | None | False | 8568.0 | 0 | 3938180 | 152217 | None | 2.3.3 | Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 2.5 mm2 | m | 44.1 | 44.1 | 450.0 | False | None | None | False | None | False | 19845.0 | 0 | 3938181 | 152217 | None | 2.3.4 | Wiringforlighting/powercircuitusingoneofFRLSPVCinsulated1100Vgrade,multistrandcopperwirewithlowconductorresistancesinglecoreinopenorconcealedsystemofwiringwithspecifiedIS-694:2010 4 mm2 | m | 66.15 | 66.15 | 150.0 | False | None | None | False | None | False | 9922.5 | 0 | 3938182 | 152217 | None | 3.4.2 | Supplyingandflushmountingpowdercoated/galvanizedmetalboxsuitableformountingmodularswitchplates.Theboxshouldbefirmlyflush mounted after due groove cutting in Brick/Stone/C.C wall 3 Way | Each | 166.95 | 166.95 | 6.0 | False | None | None | False | None | False | 1001.7 | 0 | 3938183 | 152217 | None | 3.5.2 | Supplyingandfixingsuperiorqualitymodularswitchmountingpolycarbonateplatewithnecessarysupportingbackplatewithrequirednos.ofmachinescrews,boltsnutsetc.,completeontheexistingmetal/PVC box. 3 Module | Each | 169.05 | 169.05 | 6.0 | False | None | None | False | None | False | 1014.3 | 0 | 3938184 | 152217 | None | 3.6.1 | Supplyingandfixingofmodularswitch&connectedaccessoriesonexisting modular switch plate as per IS 3854 and IS 1293.
3.6.1 6A One Way Switch | Each | 107.1 | 107.1 | 36.0 | False | None | None | False | None | False | 3855.6 | 0 | 3938185 | 152217 | None | 3.6.3 | Supplyingandfixingofmodularswitch&connectedaccessoriesonexisting modular switch plate as per IS 3854 and IS 1293. 3.6.3
6A Three Way socket | Each | 179.55 | 179.55 | 6.0 | False | None | None | False | None | False | 1077.3 | 0 | 3938186 | 152217 | None | 3.6.4 | Supplyingandfixingofmodularswitch&connectedaccessoriesonexisting modular switch plate as per IS 3854 and IS 1293.3.6.4
Stepped Fan Regulator Two Module | Each | 374.85 | 374.85 | 6.0 | False | None | None | False | None | False | 2249.1 | 0 | 3938187 | 152217 | None | 3.6.11 | Supplyingandfixingofmodularswitch&connectedaccessoriesonexisting modular switch plate as per IS 3854 and IS 1293. 3.6.11
TV/Telephone Socket | Each | 163.8 | 163.8 | 3.0 | False | None | None | False | None | False | 491.4 | 0 | 3938188 | 152217 | None | 5.18.1 | Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross-3withShortcircuitbreakingcapacityof10KandcompletewiringasrequiredconfirmingtoIEC60898.
5.18.1
6-32 A SP | Each | 435.75 | 435.75 | 3.0 | False | None | None | False | None | False | 1307.25 | 0 | 3938189 | 152217 | None | 5.18.7 | Supplying&fixingminiaturecircuitbreakersonexistingMCBdistributionboardsusingnecessaryfixingmaterialsand'C'Typecurve,indicatorON/OFF,energycross-3withShortcircuitbreakingcapacityof10KandcompletewiringasrequiredconfirmingtoIEC60898.
5.18.7
6-32 A TPN | Each | 1802.85 | 1802.85 | 3.0 | False | None | None | False | None | False | 5408.55 | 0 | 3938190 | 152217 | None | 5.33 | SupplyingofmultifunctiondigitalmeterwiththreelinebacklightLCDtypedisplayforvoltage,Current,frequency,Power,powerfactor,kVA,kWH,kVARsuitablefor3phase,4wireLTnetworkwithIP54degreeofprotectionandcompletelywiredasrequiredwithcommunication Port and Class 0.5s accuracy | Each | 9780.75 | 9780.75 | 3.0 | False | None | None | False | None | False | 29342.25 | 0 | 3938191 | 152217 | None | 5.44.2 | SupplyandInstallation/Fixing/ProvisionofOutdoortypeThermoplasticModularPanelenclosurewithtransparentPolycarbonateLid,shockproof,IP65(WeatherProof),rustproof,dustproof,waterproof,corrosionproofhavinginternallyEmbeddedgasketonbothlidandflapsuitabletofixSinglePhase/ThreePhaseEnergyMeterinsuitablebaseplateandhavingaprovisionforFuse/ MCBcut-outwithsuitabletransparenthingedflapopeningforoperating MCB along with complete tamper proof SEALING facility.5.44.2
300 mm x 450 mm x 214 mm | Each | 6471.15 | 6471.15 | 3.0 | False | None | None | False | None | False | 19413.45 | 0 | 3938192 | 152217 | None | 5.41.2 | SupplyingandfixingangleironframeworkfabricatedoutofM.S.angleiron.andM.S.Flat.withbolts,washersetc.,andpaintedwith 2 coats of red oxide and then two coats of approved paint 5.41.2
50 x 50 x 6 mm | m | 414.75 | 414.75 | 18.0 | False | None | None | False | None | False | 7465.5 | 0 | 3938193 | 152217 | None | 5.42.2 | FabricatingsupplyingandmountingMSboxmadeout.SWGsuitableforfloor/wallmounting,fullyweatherproofwithprovisionforbetterheatdissipation,providedwithhingedfrontcover,equippedwithtamperprooflockingarrangements,withsuitablesizeclampswithnecessarycableentrypipewithglandandboxshouldbefinishedwith7tankstreatmentwithpowdercoatedpaintand finally finished with approved colour etc., complete. 5.42.2
16 SWG | Sq CM | 0.45 | 0.45 | 25500.0 | False | None | None | False | None | False | 11475.0 | 0 | 3938194 | 152217 | None | 6.1 | Earthing: Sypplying, fixing wiring earth electrode for grounding conduits, IC cutouts and other equipments on the meter board using 40mm dia 2.90 thick GI pipe 2.5mtrs long burried in a pit. The pit should eb filled with equal proporation of salt and charcoal 150mm around the pipe to the complete depth. the pipe shall have 16 bos of throyugh holes of 12mm dia. Earthing | No | 2999.7 | 2999.7 | 3.0 | False | None | None | False | None | False | 8999.1 | 0 | 3938195 | 152217 | None | 6.6.2 | Digging of trench of 0.60m deep x 0.50mtrs wide refilling the trench to the required ground level and consolidating etc., In hard soil | Mtr | 102.0 | 102.0 | 15.0 | False | None | None | False | None | False | 1530.0 | 0 | 3938196 | 152217 | None | 6.4.4 | Supplying of 1.1 KV LT UG Cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT Cable as per IS - 1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms /Kms (Max) as per IS-3975 4 cover 16 sqmm | Rmtr | 150.0 | 150.0 | 24.0 | False | None | None | False | None | False | 3600.0 | 0 | 3938197 | 152217 | None | 6.5.1 | Labour charges for laying of 1.1 KV class UG cable when supplied agency in existing trench GI pipe/stonewere pipe/on wall on pole as required Existing trench/duct 6 to 16 sqmm | Mtr | 11.88 | 11.88 | 15.0 | False | None | None | False | None | False | 178.2 | 0 | 3938198 | 152217 | None | 7.3.1 | Supplying capacitor type ceiling fan complete with down rod blades, snackles, canopies, etc, for operation on 230 volts 50 cycles, single phase
AC supply conifring to IS-374-1979 and with double ball bearing sstem. 48" sweep (1200mm) regular model | No | 2949.0 | 2949.0 | 6.0 | False | None | None | False | None | False | 17694.0 | 0 | 3938199 | 152217 | None | 13.11 | Fixingaceiling/wallmountingfanofallcapacitiesandalltypes,withnecessaryclampsand'S'hookmadeoutof15mmdiaMSrod,with5A.ceilingroseofapprovedqualitywithnecessarylengthof23/0.0076inchPVCinsulatedtwintwistedwireofapprovedquality,mounted on a suitable size wooden board and wired. | Each | 330.75 | 330.75 | 6.0 | False | None | None | False | None | False | 1984.5 | 0 | 3938200 | 152217 | None | 11.3.2 | Supplyingof.feet-PVCBattenwithintegratedLEDtube.WwithhighqualitydiffuserwithLifeof25000burninghours&70%lumenmaintenancewithCRI 80. Power Input:220-240V@50/60Hz&Powerfactor 0.9alongwithCEapproved.2yearsWarrantyagainstanymanufacturingdefectworkingunderstandardelectrical condition.11.3.2
LED light fitting 1 x 4' - 20/22 W | Each | 724.5 | 724.5 | 12.0 | False | None | None | False | None | False | 8694.0 | 0 | 3938201 | 152217 | None | 13.7.1 | Fixingalltypesandallcapacitiesoffluorescent/falseceiling/spotlight/CFL/LEDfittingsindooronthewall/ceiling/rafters/girdersusing23/0.0076"twintwistedPVCinsulatedwires,requiredNosofround blocks and clamps.
13.7.1
On wall/ ceiling / Rafter / Girders | Each | 128.1 | 128.1 | 12.0 | False | None | None | False | None | False | 1537.2 | 0 |
|
|
---|