tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1725625659000 | 0 | None | None | Buildings | CONSTRUCTION OF PANDAVAPURA SUB OFFICE FOR MANMUL MANDYA DISTRICT BUILDING & PLUMBING | 28876538.81 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3936911 | 152179 | None | code01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Complete with all lead and lift as per the instruction of the Engineer in incharge. | Cum | 75.19 | 75.19 | 629.06 | False | None | None | False | None | False | 47299.0214 | 0 | 3936912 | 152179 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth 3 m to 6 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work Complete with all lead and lift as per the instruction of the Engineer in incharge. | Cum | 84.0 | 84.0 | 507.57 | False | None | None | False | None | False | 42635.88 | 0 | 3936913 | 152179 | None | code03 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. Complete with all lead and lift as per the instruction of the Engineer in incharge. | Cum | 204.0 | 204.0 | 184.62 | False | None | None | False | None | False | 37662.48 | 0 | 3936914 | 152179 | None | code04 | Loading and Unloading of Stone Boulder/Stone aggregates/Sand/Kankar/Moorum. (Tipper 18 m3) | Cum | 118.0 | 118.0 | 952.02 | False | None | None | False | None | False | 112338.36 | 0 | 3936915 | 152179 | None | code05 | Cost of Haulage Excluding Loading and Unloading, Loading and Unloading of Stone Boulder/Stone aggregates/Sand/Kankar/Moorum. (Tipper 10 m3). Basement floor Complete with all lead and lift as per the instruction of the Engineer in incharge. | Cum | 12.0 | 12.0 | 1523.23 | False | None | None | False | None | False | 18278.76 | 0 | 3936916 | 152179 | None | code06 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. Complete with all lead and lift as per the instruction of the Engineer in incharge. | Cum | 402.0 | 402.0 | 88.5 | False | None | None | False | None | False | 35577.0 | 0 | 3936917 | 152179 | None | code07 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier underand around the column pits, walls, trenches, basement excavation,top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications Complete with all lead and lift as per the instruction of the Engineer in incharge. | Sqm | 95.0 | 95.0 | 723.76 | False | None | None | False | None | False | 68757.2 | 0 | 3936918 | 152179 | None | code08 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. Ground Floor Complete with all lead and lift as per the instruction of the Engineer in incharge. | Cum | 5926.0 | 5926.0 | 118.26 | False | None | None | False | None | False | 700808.76 | 0 | 3936919 | 152179 | None | code09 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) Complete with all lead and lift as per the instruction of the Engineer in incharge. | Cum | 5422.0 | 5422.0 | 15.66 | False | None | None | False | None | False | 84908.52 | 0 | 3936920 | 152179 | None | code10 | Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. . (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates as per the directions and instructions of engineer in charge. Ground Floor Complete with all lead and lift as per the instruction of the Engineer in incharge. | Cum | 6285.0 | 6285.0 | 202.02 | False | None | None | False | None | False | 1269695.7 | 0 | 3936921 | 152179 | None | code11 | Providing, fixing and removing of formwork, Centering, shuttering and scaffolding for footing (of item No 25) complete with all lead and lift as per the direction of Engineer-In-Charge Complete with all lead and lift as per the instruction of the Engineer in incharge. | Cum | 314.25 | 314.25 | 202.02 | False | None | None | False | None | False | 63484.785 | 0 | 3936922 | 152179 | None | code12 | Providing and laying in position Reinforced cement concrete for all Sub structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - complete with all lead and lift as per the direction of Engineer-In-Charge. Ground floor Complete with all lead and lift as per the instruction of the Engineer in incharge. | Cum | 6299.0 | 6299.0 | 53.18 | False | None | None | False | None | False | 334980.82 | 0 | 3936923 | 152179 | None | code13 | Providing, fixing and removing of formwork, Centering, shuttering and scaffolding for footing. Basement floor Complete with all lead and lift as per the instruction of the Engineer in incharge. | Cum | 4409.3 | 4409.3 | 12.59 | False | None | None | False | None | False | 55513.087 | 0 | 3936924 | 152179 | None | code14 | Providing, fixing and removing of formwork, Centering, shuttering and scaffolding for plinth beam, slab & staircase Substructure Works. Basement floor complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 3149.5 | 3149.5 | 31.24 | False | None | None | False | None | False | 98390.38 | 0 | 3936925 | 152179 | None | code15 | Providing, fixing and removing of formwork, Centering, shuttering and scaffolding for RC wall Substructure Works. Basement floor complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 4409.3 | 4409.3 | 9.35 | False | None | None | False | None | False | 41226.955 | 0 | 3936926 | 152179 | None | code16 | Providing and laying in position Reinforced cement concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Ground floor Works complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 6492.0 | 6492.0 | 97.3 | False | None | None | False | None | False | 631671.6 | 0 | 3936927 | 152179 | None | code17 | Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for column. Basement floor complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 4544.0 | 4544.0 | 14.13 | False | None | None | False | None | False | 64206.72 | 0 | 3936928 | 152179 | None | code18 | Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for beam & lintels. Basement floor complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 3895.2 | 3895.2 | 27.62 | False | None | None | False | None | False | 107585.424 | 0 | 3936929 | 152179 | None | code19 | Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for slab & staircase. Basement floor complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 3246.0 | 3246.0 | 55.55 | False | None | None | False | None | False | 180315.3 | 0 | 3936930 | 152179 | None | code20 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Tonne | 69857.0 | 69857.0 | 35.61 | False | None | None | False | None | False | 2487607.77 | 0 | 3936931 | 152179 | None | code21 | Providing and laying 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per direction of Engineer incharge. Complete Ground Floor Complete with all lead and lift as per the instruction of the Engineer in incharge. | Sqm | 724.0 | 724.0 | 121.6 | False | None | None | False | None | False | 88038.4 | 0 | 3936932 | 152179 | None | code22 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding for works Ground Floor Works complete with all lead and lift as per the direction of Engineer-In-Charge | Kgs | 131.0 | 131.0 | 460.95 | False | None | None | False | None | False | 60384.45 | 0 | 3936933 | 152179 | None | code23 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) -Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 7240.0 | 7240.0 | 13.74 | False | None | None | False | None | False | 99477.6 | 0 | 3936934 | 152179 | None | code24 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) Ground Floor Works complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 4870.0 | 4870.0 | 0.9 | False | None | None | False | None | False | 4383.0 | 0 | 3936935 | 152179 | None | code25 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 90393.0 | 90393.0 | 0.15 | False | None | None | False | None | False | 13558.95 | 0 | 3936936 | 152179 | None | code26 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. do- 30 mm thick both side commercial. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 2638.0 | 2638.0 | 5.36 | False | None | None | False | None | False | 14139.68 | 0 | 3936937 | 152179 | None | code27 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Mtr | 475.0 | 475.0 | 23.94 | False | None | None | False | None | False | 11371.5 | 0 | 3936938 | 152179 | None | code28 | Providing and fixing factory made 100% carpenter friendly ready to use single solid plain wood polymer composite (WPC) flush shutter of 30mm thick which is anti terminate and having high water observation property. The cost include cost of material, transportation, labour and fixing charges. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 3478.0 | 3478.0 | 3.15 | False | None | None | False | None | False | 10955.7 | 0 | 3936939 | 152179 | None | code29 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 109.0 | 109.0 | 3.0 | False | None | None | False | None | False | 327.0 | 0 | 3936940 | 152179 | None | code30 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 880.0 | 880.0 | 3.0 | False | None | None | False | None | False | 2640.0 | 0 | 3936941 | 152179 | None | code31 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 832.0 | 832.0 | 3.0 | False | None | None | False | None | False | 2496.0 | 0 | 3936942 | 152179 | None | code32 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 237.0 | 237.0 | 6.0 | False | None | None | False | None | False | 1422.0 | 0 | 3936943 | 152179 | None | code33 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 82.0 | 82.0 | 9.0 | False | None | None | False | None | False | 738.0 | 0 | 3936944 | 152179 | None | code34 | Providing and fixing bright finished brass tower bolts(barrel type) with necessary screws etc. complete : 250x10mm, Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 337.0 | 337.0 | 9.0 | False | None | None | False | None | False | 3033.0 | 0 | 3936945 | 152179 | None | code35 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 8211.0 | 8211.0 | 52.54 | False | None | None | False | None | False | 431405.94 | 0 | 3936946 | 152179 | None | code36 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 7036.0 | 7036.0 | 15.39 | False | None | None | False | None | False | 108284.04 | 0 | 3936947 | 152179 | None | code37 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage
charges of machinery etc complete as per specifications. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 1067.0 | 1067.0 | 104.4 | False | None | None | False | None | False | 111394.8 | 0 | 3936948 | 152179 | None | code38 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge Ground Floor Works complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 2510.0 | 2510.0 | 11.52 | False | None | None | False | None | False | 28915.2 | 0 | 3936949 | 152179 | None | code39 | Providing 12 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners with chicken mesh all around the wall with smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 218.0 | 218.0 | 405.36 | False | None | None | False | None | False | 88368.48 | 0 | 3936950 | 152179 | None | code40 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge for works Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 253.0 | 253.0 | 488.94 | False | None | None | False | None | False | 123701.82 | 0 | 3936951 | 152179 | None | code41 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 83.0 | 83.0 | 894.3 | False | None | None | False | None | False | 74226.9 | 0 | 3936952 | 152179 | None | code42 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 313.0 | 313.0 | 335.98 | False | None | None | False | None | False | 105161.74 | 0 | 3936953 | 152179 | None | code43 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 1899.0 | 1899.0 | 50.6 | False | None | None | False | None | False | 96089.4 | 0 | 3936954 | 152179 | None | code44 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 2881.0 | 2881.0 | 90.03 | False | None | None | False | None | False | 259376.43 | 0 | 3936955 | 152179 | None | code45 | Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 3512.0 | 3512.0 | 5.02 | False | None | None | False | None | False | 17630.24 | 0 | 3936956 | 152179 | None | code46 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 263.0 | 263.0 | 50.2 | False | None | None | False | None | False | 13202.6 | 0 | 3936957 | 152179 | None | code47 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. - Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 616.0 | 616.0 | 7.95 | False | None | None | False | None | False | 4897.2 | 0 | 3936958 | 152179 | None | code48 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 974.0 | 974.0 | 19.47 | False | None | None | False | None | False | 18963.78 | 0 | 3936959 | 152179 | None | code49 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 1666.0 | 1666.0 | 0.41 | False | None | None | False | None | False | 683.06 | 0 | 3936960 | 152179 | None | code50 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 3458.0 | 3458.0 | 0.63 | False | None | None | False | None | False | 2178.54 | 0 | 3936961 | 152179 | None | code51 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in- Charge. Ground Floor complete with all lead and lift as per the direction of Engineer-In-Charge | Kgs | 111.0 | 111.0 | 1548.0 | False | None | None | False | None | False | 171828.0 | 0 | 3936962 | 152179 | None | code52 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 40.0 | 40.0 | 894.3 | False | None | None | False | None | False | 35772.0 | 0 | 3936963 | 152179 | None | code53 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 79.0 | 79.0 | 894.3 | False | None | None | False | None | False | 70649.7 | 0 | 3936964 | 152179 | None | code54 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 208.0 | 208.0 | 335.98 | False | None | None | False | None | False | 69883.84 | 0 | 3936965 | 152179 | None | code55 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-incharge. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 90.0 | 90.0 | 38.64 | False | None | None | False | None | False | 3477.6 | 0 | 3936966 | 152179 | None | code56 | Providing and laying Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand), Light shade pigment using white cement, Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 757.0 | 757.0 | 182.6 | False | None | None | False | None | False | 138228.2 | 0 | 3936967 | 152179 | None | code57 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 41.0 | 41.0 | 8.82 | False | None | None | False | None | False | 361.62 | 0 | 3936968 | 152179 | None | code58 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete. up to Ground Floor. | Sqm | 3939.0 | 3939.0 | 9.6 | False | None | None | False | None | False | 37814.4 | 0 | 3936969 | 152179 | None | code59 | Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi -rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g/m2,made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete. up to Ground floor. | Sqm | 1562.0 | 1562.0 | 9.6 | False | None | None | False | None | False | 14995.2 | 0 | 3936970 | 152179 | None | code60 | Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge. For payment, only the actual area of glass on face 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. up to Ground floor. | Sqm | 1731.0 | 1731.0 | 9.6 | False | None | None | False | None | False | 16617.6 | 0 | 3936971 | 152179 | None | code61 | Providing and fixing of clay tiles for cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface and the surface is painted with red apex paint and black apex paint into the groves. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification. up to Ground floor. | Sqm | 1854.0 | 1854.0 | 9.9 | False | None | None | False | None | False | 18354.6 | 0 | 3936972 | 152179 | None | code62 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railing, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. | Kgs | 108.0 | 108.0 | 587.98 | False | None | None | False | None | False | 63501.84 | 0 | 3936973 | 152179 | None | code63 | Providing and laying in position Reinforced cement concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - first floor Works complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 6492.0 | 6492.0 | 136.43 | False | None | None | False | None | False | 885703.56 | 0 | 3936974 | 152179 | None | code64 | Providing, fixing and removing of formwork, Centering, shuttering and scaffolding for column first floor complete with all lead and lift as per the direction of Engineer-In-Charge. | Cum | 4544.4 | 4544.4 | 12.24 | False | None | None | False | None | False | 55623.456 | 0 | 3936975 | 152179 | None | code65 | Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for beam & lintels. first floor complete with all lead and lift as per the direction of Engineer-In-Charge. | Cum | 3895.2 | 3895.2 | 81.17 | False | None | None | False | None | False | 316173.384 | 0 | 3936976 | 152179 | None | code66 | Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for slab & staircase. first floor complete with all lead and lift as per the direction of Engineer-In-Charge. | Cum | 3246.0 | 3246.0 | 43.02 | False | None | None | False | None | False | 139642.92 | 0 | 3936977 | 152179 | None | code67 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. First floor complete with all lead and lift as per the direction of Engineer-In-Charge. | Tonne | 69857.0 | 69857.0 | 14.96 | False | None | None | False | None | False | 1045060.72 | 0 | 3936978 | 152179 | None | code68 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 7036.0 | 7036.0 | 54.17 | False | None | None | False | None | False | 381140.12 | 0 | 3936979 | 152179 | None | code69 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 908.0 | 908.0 | 45.48 | False | None | None | False | None | False | 41295.84 | 0 | 3936980 | 152179 | None | code70 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. -first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 2017.0 | 2017.0 | 4.5 | False | None | None | False | None | False | 9076.5 | 0 | 3936981 | 152179 | None | code71 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. first floor complete with all lead and lift as per the direction of Engineer-In-Charge. | Sqm | 2510.0 | 2510.0 | 2.88 | False | None | None | False | None | False | 7228.8 | 0 | 3936982 | 152179 | None | code72 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding for works. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Kgs | 131.0 | 131.0 | 554.4 | False | None | None | False | None | False | 72626.4 | 0 | 3936983 | 152179 | None | code73 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) -first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 7240.0 | 7240.0 | 24.6 | False | None | None | False | None | False | 178104.0 | 0 | 3936984 | 152179 | None | code74 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 4870.0 | 4870.0 | 1.8 | False | None | None | False | None | False | 8766.0 | 0 | 3936985 | 152179 | None | code75 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 90393.0 | 90393.0 | 0.26 | False | None | None | False | None | False | 23502.18 | 0 | 3936986 | 152179 | None | code76 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. do- 30 mm thick both side commercial. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 2638.0 | 2638.0 | 12.6 | False | None | None | False | None | False | 33238.8 | 0 | 3936987 | 152179 | None | code77 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. first floor. | Sqm | 475.0 | 475.0 | 47.88 | False | None | None | False | None | False | 22743.0 | 0 | 3936988 | 152179 | None | code78 | Providing and fixing factory made 100% carpenter friendly ready to use single solid plain wood polymer composite (WPC) flush shutter of 30mm thick which is anti terminate and having high water observation property. The cost include cost of material, transportation, labour and fixing charges. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 3478.0 | 3478.0 | 6.3 | False | None | None | False | None | False | 21911.4 | 0 | 3936989 | 152179 | None | code79 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 109.0 | 109.0 | 6.0 | False | None | None | False | None | False | 654.0 | 0 | 3936990 | 152179 | None | code80 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 880.0 | 880.0 | 6.0 | False | None | None | False | None | False | 5280.0 | 0 | 3936991 | 152179 | None | code81 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 832.0 | 832.0 | 6.0 | False | None | None | False | None | False | 4992.0 | 0 | 3936992 | 152179 | None | code82 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 237.0 | 237.0 | 12.0 | False | None | None | False | None | False | 2844.0 | 0 | 3936993 | 152179 | None | code83 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 82.0 | 82.0 | 18.0 | False | None | None | False | None | False | 1476.0 | 0 | 3936994 | 152179 | None | code84 | Providing and fixing bright finished brass tower bolts(barrel type) with necessary screws etc. complete : 250x10mm, first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 337.0 | 337.0 | 18.0 | False | None | None | False | None | False | 6066.0 | 0 | 3936995 | 152179 | None | code85 | Providing 12 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners with chicken mesh all around the wall with smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 218.0 | 218.0 | 360.19 | False | None | None | False | None | False | 78521.42 | 0 | 3936996 | 152179 | None | code86 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge for works. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 253.0 | 253.0 | 501.82 | False | None | None | False | None | False | 126960.46 | 0 | 3936997 | 152179 | None | code87 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 83.0 | 83.0 | 710.56 | False | None | None | False | None | False | 58976.48 | 0 | 3936998 | 152179 | None | code88 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 313.0 | 313.0 | 255.38 | False | None | None | False | None | False | 79933.94 | 0 | 3936999 | 152179 | None | code89 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 1899.0 | 1899.0 | 65.36 | False | None | None | False | None | False | 124118.64 | 0 | 3937000 | 152179 | None | code90 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 2881.0 | 2881.0 | 310.8 | False | None | None | False | None | False | 895414.8 | 0 | 3937001 | 152179 | None | code91 | Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 3512.0 | 3512.0 | 10.07 | False | None | None | False | None | False | 35365.84 | 0 | 3937002 | 152179 | None | code92 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Mtr | 263.0 | 263.0 | 100.7 | False | None | None | False | None | False | 26484.1 | 0 | 3937003 | 152179 | None | code93 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. - first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 616.0 | 616.0 | 22.35 | False | None | None | False | None | False | 13767.6 | 0 | 3937004 | 152179 | None | code94 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 974.0 | 974.0 | 98.07 | False | None | None | False | None | False | 95520.18 | 0 | 3937005 | 152179 | None | code95 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 1666.0 | 1666.0 | 1.22 | False | None | None | False | None | False | 2032.52 | 0 | 3937006 | 152179 | None | code96 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 3458.0 | 3458.0 | 1.26 | False | None | None | False | None | False | 4357.08 | 0 | 3937007 | 152179 | None | code97 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in- Charge. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Kgs | 111.0 | 111.0 | 504.0 | False | None | None | False | None | False | 55944.0 | 0 | 3937008 | 152179 | None | code98 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 40.0 | 40.0 | 710.56 | False | None | None | False | None | False | 28422.4 | 0 | 3937009 | 152179 | None | code99 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 79.0 | 79.0 | 710.56 | False | None | None | False | None | False | 56134.24 | 0 | 3937010 | 152179 | None | code100 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 208.0 | 208.0 | 255.38 | False | None | None | False | None | False | 53119.04 | 0 | 3937011 | 152179 | None | code101 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-incharge. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 90.0 | 90.0 | 29.28 | False | None | None | False | None | False | 2635.2 | 0 | 3937012 | 152179 | None | code102 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 41.0 | 41.0 | 18.9 | False | None | None | False | None | False | 774.9 | 0 | 3937013 | 152179 | None | code103 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete. up to first floor. | Sqm | 3936.0 | 3936.0 | 9.6 | False | None | None | False | None | False | 37785.6 | 0 | 3937014 | 152179 | None | code104 | Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi -rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g/m2,made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete. up to first floor. | Sqm | 1562.0 | 1562.0 | 9.6 | False | None | None | False | None | False | 14995.2 | 0 | 3937015 | 152179 | None | code105 | Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge. For payment, only the actual area of glass on face 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. up to first floor. | Sqm | 1731.0 | 1731.0 | 9.6 | False | None | None | False | None | False | 16617.6 | 0 | 3937016 | 152179 | None | code106 | Providing and fixing of clay tiles for cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface and the surface is painted with red apex paint and black apex paint into the groves. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification. up to first floor. | Sqm | 1854.0 | 1854.0 | 9.9 | False | None | None | False | None | False | 18354.6 | 0 | 3937017 | 152179 | None | code107 | Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer- in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately) including cost of materials, labour, usage charges of machinery complete as per specifications.up to first floor. | Kgs | 691.0 | 691.0 | 480.0 | False | None | None | False | None | False | 331680.0 | 0 | 3937018 | 152179 | None | code108 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness (weight not less than 20 kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specificationsup to first floor. | Sqm | 1305.0 | 1305.0 | 120.0 | False | None | None | False | None | False | 156600.0 | 0 | 3937019 | 152179 | None | code109 | Providing and laying in position Reinforced cement concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - second floor Works complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 6492.0 | 6492.0 | 136.43 | False | None | None | False | None | False | 885703.56 | 0 | 3937020 | 152179 | None | code110 | Providing, fixing and removing of formwork, Centering, shuttering and scaffolding for column. second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 4544.4 | 4544.4 | 12.24 | False | None | None | False | None | False | 55623.456 | 0 | 3937021 | 152179 | None | code111 | Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for beam & lintels. second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 3895.2 | 3895.2 | 81.17 | False | None | None | False | None | False | 316173.384 | 0 | 3937022 | 152179 | None | code112 | Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for slab & staircase. second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 3246.0 | 3246.0 | 43.02 | False | None | None | False | None | False | 139642.92 | 0 | 3937023 | 152179 | None | code113 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. First floor complete with all lead and lift as per the direction of Engineer-In-Charge | Tonne | 69857.0 | 69857.0 | 14.96 | False | None | None | False | None | False | 1045060.72 | 0 | 3937024 | 152179 | None | code114 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 7036.0 | 7036.0 | 52.72 | False | None | None | False | None | False | 370937.92 | 0 | 3937025 | 152179 | None | code115 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. second floor complete with all lead and lift as per the direction of Engineer-In-Charge. | Sqm | 2510.0 | 2510.0 | 2.88 | False | None | None | False | None | False | 7228.8 | 0 | 3937026 | 152179 | None | code116 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding for works. second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Kgs | 131.0 | 131.0 | 604.8 | False | None | None | False | None | False | 79228.8 | 0 | 3937027 | 152179 | None | code117 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) -second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 7240.0 | 7240.0 | 28.8 | False | None | None | False | None | False | 208512.0 | 0 | 3937028 | 152179 | None | code118 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 90393.0 | 90393.0 | 0.07 | False | None | None | False | None | False | 6327.51 | 0 | 3937029 | 152179 | None | code119 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. do- 30 mm thick both side commercial. second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 2638.0 | 2638.0 | 2.52 | False | None | None | False | None | False | 6647.76 | 0 | 3937030 | 152179 | None | code120 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 109.0 | 109.0 | 1.0 | False | None | None | False | None | False | 109.0 | 0 | 3937031 | 152179 | None | code121 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 880.0 | 880.0 | 1.0 | False | None | None | False | None | False | 880.0 | 0 | 3937032 | 152179 | None | code122 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 832.0 | 832.0 | 1.0 | False | None | None | False | None | False | 832.0 | 0 | 3937033 | 152179 | None | code123 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete. second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 237.0 | 237.0 | 2.0 | False | None | None | False | None | False | 474.0 | 0 | 3937034 | 152179 | None | code124 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm. second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 82.0 | 82.0 | 3.0 | False | None | None | False | None | False | 246.0 | 0 | 3937035 | 152179 | None | code125 | Providing and fixing bright finished brass tower bolts(barrel type) with necessary screws etc. complete : 250x10mm, second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 337.0 | 337.0 | 3.0 | False | None | None | False | None | False | 1011.0 | 0 | 3937036 | 152179 | None | code126 | Providing 12 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners with chicken mesh all around the wall with smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 218.0 | 218.0 | 360.19 | False | None | None | False | None | False | 78521.42 | 0 | 3937037 | 152179 | None | code127 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge for works. second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 253.0 | 253.0 | 308.56 | False | None | None | False | None | False | 78065.68 | 0 | 3937038 | 152179 | None | code128 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 366.0 | 366.0 | 668.75 | False | None | None | False | None | False | 244762.5 | 0 | 3937039 | 152179 | None | code129 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 371.0 | 371.0 | 252.78 | False | None | None | False | None | False | 93781.38 | 0 | 3937040 | 152179 | None | code130 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 2466.0 | 2466.0 | 64.25 | False | None | None | False | None | False | 158440.5 | 0 | 3937041 | 152179 | None | code131 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 2852.0 | 2852.0 | 310.8 | False | None | None | False | None | False | 886401.6 | 0 | 3937042 | 152179 | None | code132 | Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 3498.0 | 3498.0 | 10.37 | False | None | None | False | None | False | 36274.26 | 0 | 3937043 | 152179 | None | code133 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Mtr | 328.0 | 328.0 | 104.78 | False | None | None | False | None | False | 34367.84 | 0 | 3937044 | 152179 | None | code134 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in- Charge. second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Kgs | 111.0 | 111.0 | 552.0 | False | None | None | False | None | False | 61272.0 | 0 | 3937045 | 152179 | None | code135 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 40.0 | 40.0 | 668.75 | False | None | None | False | None | False | 26750.0 | 0 | 3937046 | 152179 | None | code136 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 79.0 | 79.0 | 668.75 | False | None | None | False | None | False | 52831.25 | 0 | 3937047 | 152179 | None | code137 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 208.0 | 208.0 | 252.78 | False | None | None | False | None | False | 52578.24 | 0 | 3937048 | 152179 | None | code138 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-incharge. second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 90.0 | 90.0 | 32.7 | False | None | None | False | None | False | 2943.0 | 0 | 3937049 | 152179 | None | code139 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 41.0 | 41.0 | 2.52 | False | None | None | False | None | False | 103.32 | 0 | 3937050 | 152179 | None | code140 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete second floor. | Sqm | 3939.0 | 3939.0 | 9.6 | False | None | None | False | None | False | 37814.4 | 0 | 3937051 | 152179 | None | code141 | Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi -rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g/m2,made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete. up to second floor. | Sqm | 1939.0 | 1939.0 | 9.6 | False | None | None | False | None | False | 18614.4 | 0 | 3937052 | 152179 | None | code142 | Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge. For payment, only the actual area of glass on face 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. second floor | Sqm | 1562.0 | 1562.0 | 9.6 | False | None | None | False | None | False | 14995.2 | 0 | 3937053 | 152179 | None | code143 | Providing and fixing of clay tiles for cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface and the surface is painted with red apex paint and black apex paint into the groves. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification. second floor | Sqm | 1731.0 | 1731.0 | 9.9 | False | None | None | False | None | False | 17136.9 | 0 | 3937054 | 152179 | None | code144 | Providing and fixing powder coated aluminium work (minimum thickness of powder coating 50 micron) consisting of tee/ angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P. brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I. level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer- in-charge (level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately) including cost of materials, labour, usage charges of machinery complete as per specifications.up to first floor. | Kgs | 691.0 | 691.0 | 25.8 | False | None | None | False | None | False | 17827.8 | 0 | 3937055 | 152179 | None | code145 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness (weight not less than 20 kg/ m²) including cost of materials, labour, usage charges of machinery complete as per specificationsup to first floor. | Sqm | 1305.0 | 1305.0 | 6.45 | False | None | None | False | None | False | 8417.25 | 0 | 3937056 | 152179 | None | code146 | Providing and laying in position Reinforced cement concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - third floor Works complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 6492.0 | 6492.0 | 36.38 | False | None | None | False | None | False | 236178.96 | 0 | 3937057 | 152179 | None | code147 | Providing, fixing and removing of formwork, Centering, shuttering and scaffolding for column. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 4544.4 | 4544.4 | 11.16 | False | None | None | False | None | False | 50715.504 | 0 | 3937058 | 152179 | None | code148 | Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for beam & lintels. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 3895.2 | 3895.2 | 12.28 | False | None | None | False | None | False | 47833.056 | 0 | 3937059 | 152179 | None | code149 | Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for slab & staircase. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 3246.0 | 3246.0 | 12.95 | False | None | None | False | None | False | 42035.7 | 0 | 3937060 | 152179 | None | code150 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Tonne | 69857.0 | 69857.0 | 3.83 | False | None | None | False | None | False | 267552.31 | 0 | 3937061 | 152179 | None | code151 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 7036.0 | 7036.0 | 39.8 | False | None | None | False | None | False | 280032.8 | 0 | 3937062 | 152179 | None | code152 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 2510.0 | 2510.0 | 59.28 | False | None | None | False | None | False | 148792.8 | 0 | 3937063 | 152179 | None | code153 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. -third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 2017.0 | 2017.0 | 4.5 | False | None | None | False | None | False | 9076.5 | 0 | 3937064 | 152179 | None | code154 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding for works. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Kgs | 131.0 | 131.0 | 223.65 | False | None | None | False | None | False | 29298.15 | 0 | 3937065 | 152179 | None | code155 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) -third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 7240.0 | 7240.0 | 8.4 | False | None | None | False | None | False | 60816.0 | 0 | 3937066 | 152179 | None | code156 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 4870.0 | 4870.0 | 2.25 | False | None | None | False | None | False | 10957.5 | 0 | 3937067 | 152179 | None | code157 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 90393.0 | 90393.0 | 0.26 | False | None | None | False | None | False | 23502.18 | 0 | 3937068 | 152179 | None | code158 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. do- 30 mm thick both side commercial. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 2638.0 | 2638.0 | 12.6 | False | None | None | False | None | False | 33238.8 | 0 | 3937069 | 152179 | None | code159 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. third floor. | Sqm | 475.0 | 475.0 | 47.88 | False | None | None | False | None | False | 22743.0 | 0 | 3937070 | 152179 | None | code160 | Providing and fixing factory made 100% carpenter friendly ready to use single solid plain wood polymer composite (WPC) flush shutter of 30mm thick which is anti terminate and having high water observation property. The cost include cost of material, transportation, labour and fixing charges. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 3478.0 | 3478.0 | 6.3 | False | None | None | False | None | False | 21911.4 | 0 | 3937071 | 152179 | None | code161 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 109.0 | 109.0 | 6.0 | False | None | None | False | None | False | 654.0 | 0 | 3937072 | 152179 | None | code162 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 880.0 | 880.0 | 6.0 | False | None | None | False | None | False | 5280.0 | 0 | 3937073 | 152179 | None | code163 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 832.0 | 832.0 | 6.0 | False | None | None | False | None | False | 4992.0 | 0 | 3937074 | 152179 | None | code164 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 237.0 | 237.0 | 12.0 | False | None | None | False | None | False | 2844.0 | 0 | 3937075 | 152179 | None | code165 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 82.0 | 82.0 | 18.0 | False | None | None | False | None | False | 1476.0 | 0 | 3937076 | 152179 | None | code166 | Providing and fixing bright finished brass tower bolts(barrel type) with necessary screws etc. complete : 250x10mm, third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 337.0 | 337.0 | 18.0 | False | None | None | False | None | False | 6066.0 | 0 | 3937077 | 152179 | None | code167 | Providing 12 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners with chicken mesh all around the wall with smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 218.0 | 218.0 | 67.17 | False | None | None | False | None | False | 14643.06 | 0 | 3937078 | 152179 | None | code168 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge for works. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 253.0 | 253.0 | 419.37 | False | None | None | False | None | False | 106100.61 | 0 | 3937079 | 152179 | None | code169 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 83.0 | 83.0 | 329.91 | False | None | None | False | None | False | 27382.53 | 0 | 3937080 | 152179 | None | code170 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 313.0 | 313.0 | 145.85 | False | None | None | False | None | False | 45651.05 | 0 | 3937081 | 152179 | None | code171 | Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 1899.0 | 1899.0 | 50.6 | False | None | None | False | None | False | 96089.4 | 0 | 3937082 | 152179 | None | code172 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 2881.0 | 2881.0 | 54.63 | False | None | None | False | None | False | 157389.03 | 0 | 3937083 | 152179 | None | code173 | Providing and fixing 20mm thick gang saw water cut Lakared granite for cladding in CM 1:3 (1 cement : 3 coarse sand) proportion with a coat of rough plastering using CM 1:4 (1 cement : 4 fine sand), cut to required shape, pattern with paper joints, finished with cement mortar using white cement and colour pigments to match the colour of slab making through jointing with sealant, grooves in joints including cost of curing etc., complete including cost and conveyance of all materials, mortar, labour for all items of work, usage charges of machinery etc., complete as per specification. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 3512.0 | 3512.0 | 3.83 | False | None | None | False | None | False | 13450.96 | 0 | 3937084 | 152179 | None | code174 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge.third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Mtr | 263.0 | 263.0 | 38.3 | False | None | None | False | None | False | 10072.9 | 0 | 3937085 | 152179 | None | code175 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/m2 including pointing the joints with white cement and matching pigment etc., complete. - third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 616.0 | 616.0 | 15.6 | False | None | None | False | None | False | 9609.6 | 0 | 3937086 | 152179 | None | code176 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 974.0 | 974.0 | 111.32 | False | None | None | False | None | False | 108425.68 | 0 | 3937087 | 152179 | None | code177 | Providing and fixing granite stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in- charge and finished smooth. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 1666.0 | 1666.0 | 1.22 | False | None | None | False | None | False | 2032.52 | 0 | 3937088 | 152179 | None | code178 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Area of slab over 0.50 m2. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 3458.0 | 3458.0 | 1.26 | False | None | None | False | None | False | 4357.08 | 0 | 3937089 | 152179 | None | code179 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in- Charge. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Kgs | 111.0 | 111.0 | 288.0 | False | None | None | False | None | False | 31968.0 | 0 | 3937090 | 152179 | None | code180 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. . third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 40.0 | 40.0 | 329.91 | False | None | None | False | None | False | 13196.4 | 0 | 3937091 | 152179 | None | code181 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 79.0 | 79.0 | 329.91 | False | None | None | False | None | False | 26062.89 | 0 | 3937092 | 152179 | None | code182 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 208.0 | 208.0 | 145.85 | False | None | None | False | None | False | 30336.8 | 0 | 3937093 | 152179 | None | code183 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-incharge. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 90.0 | 90.0 | 10.65 | False | None | None | False | None | False | 958.5 | 0 | 3937094 | 152179 | None | code184 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. third floor complete with all lead and lift as per the direction of Engineer-In-Charge. | Sqm | 41.0 | 41.0 | 18.9 | False | None | None | False | None | False | 774.9 | 0 | 3937095 | 152179 | None | code185 | Providing and fixing of Aluminium composite panel of approved make and colour for wall cladding for Brick/Rcc/stone walls & coloumns/beams with necessary aluminium frame works at required level made out of 50x25x4mm C section or equivalent. The panel should consist of 3mm thick non-halogenated FR grade mineral based polymer ( 2 hrs fire resistance as per ASTM E119-12 and clause B, S1, do as per ENT 13501-1sandwiched between 0.50 skins thick aluminium sheet making a total panel thickness of 4mm. The surfaces will be finished with PVDF based coating on topsides and service coating on reverse sides would be in polyester paint. The system shall be fixed using GI brackets, aluminium L cleats and stainless steel bolts and nuts complete with spring washer and cap nuts and all other necessary accessories, sealing shall be done with necessary rods etc., complete. up to third floor complete with all lead and lift as per the direction of Engineer-In-Charge. | Sqm | 3939.0 | 3939.0 | 9.6 | False | None | None | False | None | False | 37814.4 | 0 | 3937096 | 152179 | None | code186 | Providing, fabricating and supplying shadow box of required size and shape, for fixing in the spandrel portion of the structural glazing, in linear as well as curvilinear portions of the building by providing semi -rigid, inorganic, non-combustible fibre glass wool insulation 50 mm thick, conforming to IS: 8183 and BS: 3958 Part 5. The insulation layer shall have facing (factory bonded on surface 1 of the fibre glass insulation layer), of black non-woven fibre glass tissue of nominal thickness 0.5 mm and nominal mass not less than 60 g/m2,made of randomly oriented glass fibres distributed in a binder by a wet-lay process including fixing 1.5 mm thick solid aluminum sheet backing using, 6 mm thick cement board including SS rivets, nuts, bolts, washers etc complete. up to third floor complete with all lead and lift as per the direction of Engineer-In-Charge. | Sqm | 1562.0 | 1562.0 | 9.6 | False | None | None | False | None | False | 14995.2 | 0 | 3937097 | 152179 | None | code187 | Providing and supplying Spandrel Glass Panels comprising of 6 mm thick heat strengthened monolithic float glass of approved colour and shade with reflective soft coating on surface 2 of approved colour and shade so as to match the colour and shade of the IGUs in the vision panels etc. ,all complete for the required performances as specified, as per the Architectural drawings, as per the approved shop drawings, as specified, and as directed by the Engineer- in- Charge. For payment, only the actual area of glass on face 1 of the glass panels (but excluding the area of grooves and weather silicone sealant) provided and fixed in position, shall be measured in m2. (Payment for fixing of Spandrel Glass Panels in the curtain glazing is included in cost of relevent Item*).“(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face 2, having properties as visible Light transmittance (VLT) of 25 to 35 %, Light reflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 K etc. . The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. up to third floor complete with all lead and lift as per the direction of Engineer-In-Charge. | Sqm | 1731.0 | 1731.0 | 9.6 | False | None | None | False | None | False | 16617.6 | 0 | 3937098 | 152179 | None | code188 | Providing and fixing of clay tiles for cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface and the surface is painted with red apex paint and black apex paint into the groves. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification. up to third floor complete with all lead and lift as per the direction of Engineer-In-Charge. | Sqm | 1854.0 | 1854.0 | 3.3 | False | None | None | False | None | False | 6118.2 | 0 | 3937099 | 152179 | None | code189 | Providing and laying in position Reinforced cement concrete for all Super structures ofbuilding , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates - Terrace Floor Works complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 6492.0 | 6492.0 | 22.75 | False | None | None | False | None | False | 147693.0 | 0 | 3937100 | 152179 | None | code190 | Providing, fixing and removing of formwork, Centering, shuttering and scaffolding for column. Terrace floor complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 4544.4 | 4544.4 | 6.03 | False | None | None | False | None | False | 27402.732 | 0 | 3937101 | 152179 | None | code191 | Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for beam & lintels. Terrace floor complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 3895.2 | 3895.2 | 7.46 | False | None | None | False | None | False | 29058.192 | 0 | 3937102 | 152179 | None | code192 | Providing, fixing and removing of formwork, Centering, shuttering and scaffolding (of Item No 32) for slab & staircase. Terrace floor complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 3246.0 | 3246.0 | 9.25 | False | None | None | False | None | False | 30025.5 | 0 | 3937103 | 152179 | None | code193 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Terrace floor complete with all lead and lift as per the direction of Engineer-In-Charge | Tonne | 69857.0 | 69857.0 | 2.45 | False | None | None | False | None | False | 171149.65 | 0 | 3937104 | 152179 | None | code194 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. Terrace floor complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 7036.0 | 7036.0 | 165.92 | False | None | None | False | None | False | 1167413.12 | 0 | 3937105 | 152179 | None | code195 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding for works Terrace floor complete with all lead and lift as per the direction of Engineer-In-Charge | Kgs | 131.0 | 131.0 | 138.6 | False | None | None | False | None | False | 18156.6 | 0 | 3937106 | 152179 | None | code196 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile throughout the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) -Terrace floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 7240.0 | 7240.0 | 6.6 | False | None | None | False | None | False | 47784.0 | 0 | 3937107 | 152179 | None | code197 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. Terrace floor complete with all lead and lift as per the direction of Engineer-In-Charge | Cum | 90393.0 | 90393.0 | 0.07 | False | None | None | False | None | False | 6327.51 | 0 | 3937108 | 152179 | None | code198 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. do- 30 mm thick both side commercial. Terrace floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 2638.0 | 2638.0 | 2.52 | False | None | None | False | None | False | 6647.76 | 0 | 3937109 | 152179 | None | code199 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. Terrace floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 109.0 | 109.0 | 1.0 | False | None | None | False | None | False | 109.0 | 0 | 3937110 | 152179 | None | code200 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. Terrace floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 880.0 | 880.0 | 1.0 | False | None | None | False | None | False | 880.0 | 0 | 3937111 | 152179 | None | code201 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete. Terrace floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 832.0 | 832.0 | 1.0 | False | None | None | False | None | False | 832.0 | 0 | 3937112 | 152179 | None | code202 | Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. complete Terrace floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 237.0 | 237.0 | 2.0 | False | None | None | False | None | False | 474.0 | 0 | 3937113 | 152179 | None | code203 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm Terrace floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 82.0 | 82.0 | 3.0 | False | None | None | False | None | False | 246.0 | 0 | 3937114 | 152179 | None | code204 | Providing and fixing bright finished brass tower bolts(barrel type) with necessary screws etc. complete : 250x10mm, Terrace floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 337.0 | 337.0 | 3.0 | False | None | None | False | None | False | 1011.0 | 0 | 3937115 | 152179 | None | code205 | Providing 12 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners with chicken mesh all around the wall with smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Terrace floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 218.0 | 218.0 | 56.83 | False | None | None | False | None | False | 12388.94 | 0 | 3937116 | 152179 | None | code206 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge for works Terrace floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 253.0 | 253.0 | 147.83 | False | None | None | False | None | False | 37400.99 | 0 | 3937117 | 152179 | None | code207 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Terrace floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 83.0 | 83.0 | 204.66 | False | None | None | False | None | False | 16986.78 | 0 | 3937118 | 152179 | None | code208 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Terrace floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 313.0 | 313.0 | 378.65 | False | None | None | False | None | False | 118517.45 | 0 | 3937119 | 152179 | None | code209 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in- Charge. Terrace floor complete with all lead and lift as per the direction of Engineer-In-Charge | Kgs | 111.0 | 111.0 | 990.0 | False | None | None | False | None | False | 109890.0 | 0 | 3937120 | 152179 | None | code210 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Terrace floorcomplete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 40.0 | 40.0 | 204.66 | False | None | None | False | None | False | 8186.4 | 0 | 3937121 | 152179 | None | code211 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge. Terrace floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 79.0 | 79.0 | 204.66 | False | None | None | False | None | False | 16168.14 | 0 | 3937122 | 152179 | None | code212 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Terrace floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 208.0 | 208.0 | 378.65 | False | None | None | False | None | False | 78759.2 | 0 | 3937123 | 152179 | None | code213 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-incharge. Terrace floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 90.0 | 90.0 | 7.15 | False | None | None | False | None | False | 643.5 | 0 | 3937124 | 152179 | None | code214 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre as per specifications and as per directions of Engineer in charge. Terrace floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 41.0 | 41.0 | 2.52 | False | None | None | False | None | False | 103.32 | 0 | 3937125 | 152179 | None | code215 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace / Chajjas / Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction ofthe Engineer In charge. - Terrace floorcomplete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 745.0 | 745.0 | 345.6 | False | None | None | False | None | False | 257472.0 | 0 | 3937126 | 152179 | None | code216 | Providing and fixing Heat Resistant Terrace Tiles (300 mm x 300 mm x 20 mm) with SRI (solar refractive index) 78, solar reflection 0.70 and initial emittance 0.75 on waterproof and sloped surface of terrace, laid on 20 mm thick cement sand mortar in the ratio of 1:4 (1 cement : 4 coarse sand) and grouting the joints with mix of white cement & marble powder in ratio of 1:1, including rubbing and polishing of the surface upto 3 cuts complete, including providing skirting upto 150 mm height along the parapet walls in the same manner as per direction of incharge.-Terrace floor complete with all lead and lift as per the direction of Engineer-In-Charge | Sqm | 1095.0 | 1095.0 | 234.0 | False | None | None | False | None | False | 256230.0 | 0 | 3937127 | 152179 | None | code217 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railing, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. | Kgs | 108.0 | 108.0 | 320.0 | False | None | None | False | None | False | 34560.0 | 0 | 3937128 | 152179 | None | code218 | Providing and Installing Air Conditioner 2 tonne machine Branded including all fittings with accessiors & Labour charges. | Nos | 65000.0 | 65000.0 | 5.0 | False | None | None | False | None | False | 325000.0 | 0 | 3937129 | 152179 | None | code219 | Providing all furnitures and tables for staff and DM & Directors Cabin with branded materials including fiitings, Transporting and Labour Cost. | Nos | 20000.0 | 20000.0 | 11.0 | False | None | None | False | None | False | 220000.0 | 0 | 3937130 | 152179 | None | code220 | Chairs for Office Staffs | Nos | 4500.0 | 4500.0 | 35.0 | False | None | None | False | None | False | 157500.0 | 0 | 3937131 | 152179 | None | code221 | DM & Directors Cabin Table | Nos | 50000.0 | 50000.0 | 3.0 | False | None | None | False | None | False | 150000.0 | 0 | 3937132 | 152179 | None | code222 | DM & Directors Cabin Chairs | Nos | 15000.0 | 15000.0 | 15.0 | False | None | None | False | None | False | 225000.0 | 0 | 3937133 | 152179 | None | code223 | Nilkamal Italia 3 Seater Bench (Silver) | Nos | 15000.0 | 15000.0 | 8.0 | False | None | None | False | None | False | 120000.0 | 0 | 3937134 | 152179 | None | code224 | Providing and Installing Statue including Transportation and Labour Charges | Nos | 300000.0 | 300000.0 | 1.0 | False | None | None | False | None | False | 300000.0 | 0 | 3937135 | 152179 | None | code225 | Constructing brick masonry chamber of internal dimension 600x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 4791.0 | 4791.0 | 8.0 | False | None | None | False | None | False | 38328.0 | 0 | 3937136 | 152179 | None | code226 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 5454.0 | 5454.0 | 2.0 | False | None | None | False | None | False | 10908.0 | 0 | 3937137 | 152179 | None | code227 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.In all kinds of soils. Depth upto 1.50m complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 484.0 | 484.0 | 16.2 | False | None | None | False | None | False | 7840.8 | 0 | 3937138 | 152179 | None | code228 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 complete with all lead and lift as per the direction of Engineer-In-Charge | Mtr | 411.0 | 411.0 | 65.0 | False | None | None | False | None | False | 26715.0 | 0 | 3937139 | 152179 | None | code229 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 140mm dia., 6 kg/sqcm & class 3 complete with all lead and lift as per the direction of Engineer-In-Charge | Mtr | 584.0 | 584.0 | 65.0 | False | None | None | False | None | False | 37960.0 | 0 | 3937140 | 152179 | None | code230 | Providing and placing on terrace (at all floor levels), polyethylene water storage tanks, IS:127001 marked, with cover and suitable locking arrangements, making necessary holes for inlet, outlet and over flow pipes but without fittings and the base support for tank. complete with all lead and lift as per the direction of Engineer-In-Charge | Ltr | 9.0 | 9.0 | 4000.0 | False | None | None | False | None | False | 36000.0 | 0 | 3937141 | 152179 | None | code231 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm Dia (Ground Floor) complete with all lead and lift as per the direction of Engineer-In-Charge | Mtr | 217.0 | 217.0 | 40.0 | False | None | None | False | None | False | 8680.0 | 0 | 3937142 | 152179 | None | code232 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm Dia (first floor) complete with all lead and lift as per the direction of Engineer-In-Charge | Mtr | 217.0 | 217.0 | 30.0 | False | None | None | False | None | False | 6510.0 | 0 | 3937143 | 152179 | None | code233 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm Dia (second floor) complete with all lead and lift as per the direction of Engineer-In-Charge | Mtr | 217.0 | 217.0 | 25.0 | False | None | None | False | None | False | 5425.0 | 0 | 3937144 | 152179 | None | code234 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 20 mm Dia (third floor) complete with all lead and lift as per the direction of Engineer-In-Charge | Mtr | 296.0 | 296.0 | 20.0 | False | None | None | False | None | False | 5920.0 | 0 | 3937145 | 152179 | None | code235 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm Dia (Ground Floor) complete with all lead and lift as per the direction of Engineer-In-Charge | Mtr | 296.0 | 296.0 | 40.0 | False | None | None | False | None | False | 11840.0 | 0 | 3937146 | 152179 | None | code236 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm Dia (first floor) complete with all lead and lift as per the direction of Engineer-In-Charge | Mtr | 296.0 | 296.0 | 30.0 | False | None | None | False | None | False | 8880.0 | 0 | 3937147 | 152179 | None | code237 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm Dia (second floor) complete with all lead and lift as per the direction of Engineer-In-Charge | Mtr | 296.0 | 296.0 | 25.0 | False | None | None | False | None | False | 7400.0 | 0 | 3937148 | 152179 | None | code238 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm Dia (third floor) complete with all lead and lift as per the direction of Engineer-In-Charge | Mtr | 372.0 | 372.0 | 20.0 | False | None | None | False | None | False | 7440.0 | 0 | 3937149 | 152179 | None | code239 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm Dia (Ground Floor) complete with all lead and lift as per the direction of Engineer-In-Charge. | Mtr | 372.0 | 372.0 | 40.0 | False | None | None | False | None | False | 14880.0 | 0 | 3937150 | 152179 | None | code240 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm Dia (first floor) complete with all lead and lift as per the direction of Engineer-In-Charge. | Mtr | 372.0 | 372.0 | 30.0 | False | None | None | False | None | False | 11160.0 | 0 | 3937151 | 152179 | None | code241 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm Dia (second floor) complete with all lead and lift as per the direction of Engineer-In-Charge. | Mtr | 372.0 | 372.0 | 25.0 | False | None | None | False | None | False | 9300.0 | 0 | 3937152 | 152179 | None | code242 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm Dia (third floor) complete with all lead and lift as per the direction of Engineer-In-Charge. | Mtr | 721.0 | 721.0 | 20.0 | False | None | None | False | None | False | 14420.0 | 0 | 3937153 | 152179 | None | code243 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm Dia ( Ground Floor) complete with all lead and lift as per the direction of Engineer-In-Charge. | Mtr | 721.0 | 721.0 | 40.0 | False | None | None | False | None | False | 28840.0 | 0 | 3937154 | 152179 | None | code244 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm Dia (first floor) complete with all lead and lift as per the direction of Engineer-In-Charge | Mtr | 721.0 | 721.0 | 30.0 | False | None | None | False | None | False | 21630.0 | 0 | 3937155 | 152179 | None | code245 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm Dia (second floor) complete with all lead and lift as per the direction of Engineer-In-Charge | Mtr | 721.0 | 721.0 | 25.0 | False | None | None | False | None | False | 18025.0 | 0 | 3937156 | 152179 | None | code246 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings, this includes jointing of pipes and fittings with one step solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm Dia (third floor) complete with all lead and lift as per the direction of Engineer-In-Charge | Mtr | 286.0 | 286.0 | 20.0 | False | None | None | False | None | False | 5720.0 | 0 | 3937157 | 152179 | None | code247 | Providing and fixing in position brass bib cock of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (Ground Floor) complete with all lead and lift as per the direction of Engineer-In-Charge. | Each | 286.0 | 286.0 | 6.0 | False | None | None | False | None | False | 1716.0 | 0 | 3937158 | 152179 | None | code248 | Providing and fixing in position brass bib cock of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (first floor) complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 286.0 | 286.0 | 10.0 | False | None | None | False | None | False | 2860.0 | 0 | 3937159 | 152179 | None | code249 | Providing and fixing in position brass bib cock of approved quality 15mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (third floor) complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 286.0 | 286.0 | 10.0 | False | None | None | False | None | False | 2860.0 | 0 | 3937160 | 152179 | None | code250 | Providing and fixing in position brass bib cock of approved quality 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (Ground Floor) complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 305.0 | 305.0 | 6.0 | False | None | None | False | None | False | 1830.0 | 0 | 3937161 | 152179 | None | code251 | Providing and fixing in position brass bib cock of approved quality 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (first floor) complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 305.0 | 305.0 | 10.0 | False | None | None | False | None | False | 3050.0 | 0 | 3937162 | 152179 | None | code252 | Providing and fixing in position brass bib cock of approved quality 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. (third floor) complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 305.0 | 305.0 | 10.0 | False | None | None | False | None | False | 3050.0 | 0 | 3937163 | 152179 | None | code253 | Providing and fixing ball valve (brass) of approved quality, High or low-pressure, with plastic floats complete : 20 mm Dia ( Ground Floor) complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 314.0 | 314.0 | 5.0 | False | None | None | False | None | False | 1570.0 | 0 | 3937164 | 152179 | None | code254 | Providing and fixing ball valve (brass) of approved quality, High or low-pressure, with plastic floats complete : 20 mm Dia (first floor) complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 314.0 | 314.0 | 5.0 | False | None | None | False | None | False | 1570.0 | 0 | 3937165 | 152179 | None | code255 | Providing and fixing ball valve (brass) of approved quality, High or low-pressure, with plastic floats complete : 20 mm Dia (second floor) complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 314.0 | 314.0 | 5.0 | False | None | None | False | None | False | 1570.0 | 0 | 3937166 | 152179 | None | code256 | Providing and fixing ball valve (brass) of approved quality, High or low-pressure, with plastic floats complete : 20 mm Dia (second floor) complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 332.0 | 332.0 | 5.0 | False | None | None | False | None | False | 1660.0 | 0 | 3937167 | 152179 | None | code257 | Providing and fixing ball valve (brass) of approved quality, High or low-pressure, with plastic floats complete : 25 mm Dia ( Ground Floor) complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 332.0 | 332.0 | 2.0 | False | None | None | False | None | False | 664.0 | 0 | 3937168 | 152179 | None | code258 | Providing and fixing ball valve (brass) of approved quality, High or low-pressure, with plastic floats complete : 25 mm Dia (first floor) complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 332.0 | 332.0 | 2.0 | False | None | None | False | None | False | 664.0 | 0 | 3937169 | 152179 | None | code259 | Providing and fixing ball valve (brass) of approved quality, High or low-pressure, with plastic floats complete : 25 mm Dia (second floor) complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 332.0 | 332.0 | 2.0 | False | None | None | False | None | False | 664.0 | 0 | 3937170 | 152179 | None | code260 | Providing and fixing ball valve (brass) of approved quality, High or low-pressure, with plastic floats complete : 25 mm Dia (third floor) complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 332.0 | 332.0 | 2.0 | False | None | None | False | None | False | 664.0 | 0 | 3937171 | 152179 | None | code261 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps Ground Floor complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 2529.0 | 2529.0 | 2.0 | False | None | None | False | None | False | 5058.0 | 0 | 3937172 | 152179 | None | code262 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 3082.0 | 3082.0 | 5.0 | False | None | None | False | None | False | 15410.0 | 0 | 3937173 | 152179 | None | code263 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 3082.0 | 3082.0 | 4.0 | False | None | None | False | None | False | 12328.0 | 0 | 3937174 | 152179 | None | code264 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 496.0 | 496.0 | 3.0 | False | None | None | False | None | False | 1488.0 | 0 | 3937175 | 152179 | None | code265 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 496.0 | 496.0 | 3.0 | False | None | None | False | None | False | 1488.0 | 0 | 3937176 | 152179 | None | code266 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. second floor complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 496.0 | 496.0 | 3.0 | False | None | None | False | None | False | 1488.0 | 0 | 3937177 | 152179 | None | code267 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm Ground Floor complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 1018.0 | 1018.0 | 2.0 | False | None | None | False | None | False | 2036.0 | 0 | 3937178 | 152179 | None | code268 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 1018.0 | 1018.0 | 3.0 | False | None | None | False | None | False | 3054.0 | 0 | 3937179 | 152179 | None | code269 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing : Rectangular shape 453x357 mm third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 1018.0 | 1018.0 | 2.0 | False | None | None | False | None | False | 2036.0 | 0 | 3937180 | 152179 | None | code270 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests First Floor complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 4884.0 | 4884.0 | 2.0 | False | None | None | False | None | False | 9768.0 | 0 | 3937181 | 152179 | None | code271 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 4884.0 | 4884.0 | 2.0 | False | None | None | False | None | False | 9768.0 | 0 | 3937182 | 152179 | None | code272 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 5977.0 | 5977.0 | 2.0 | False | None | None | False | None | False | 11954.0 | 0 | 3937183 | 152179 | None | code273 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid Ground Floor complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 5977.0 | 5977.0 | 1.0 | False | None | None | False | None | False | 5977.0 | 0 | 3937184 | 152179 | None | code274 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 5977.0 | 5977.0 | 2.0 | False | None | None | False | None | False | 11954.0 | 0 | 3937185 | 152179 | None | code275 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 5977.0 | 5977.0 | 2.0 | False | None | None | False | None | False | 11954.0 | 0 | 3937186 | 152179 | None | code276 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern as per the directions and instructions of engineer in charge. Ground Floor complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 4454.0 | 4454.0 | 2.0 | False | None | None | False | None | False | 8908.0 | 0 | 3937187 | 152179 | None | code277 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern as per the directions and instructions of engineer in charge. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 4454.0 | 4454.0 | 2.0 | False | None | None | False | None | False | 8908.0 | 0 | 3937188 | 152179 | None | code278 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :One urinal basin with 5 litre white P.V.C. automatic flushing cistern as per the directions and instructions of engineer in charge. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 4454.0 | 4454.0 | 2.0 | False | None | None | False | None | False | 8908.0 | 0 | 3937189 | 152179 | None | code279 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: * 100mm inlet and 100mm outlet * Sand Cast Iron S&S as per IS:1729 Ground Floor complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 1392.0 | 1392.0 | 4.0 | False | None | None | False | None | False | 5568.0 | 0 | 3937190 | 152179 | None | code280 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: * 100mm inlet and 100mm outlet * Sand Cast Iron S&S as per IS:1729 first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 1392.0 | 1392.0 | 8.0 | False | None | None | False | None | False | 11136.0 | 0 | 3937191 | 152179 | None | code281 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete, including cost of cutting and making good the walls and floors: * 100mm inlet and 100mm outlet * Sand Cast Iron S&S as per IS:1729 third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 1392.0 | 1392.0 | 8.0 | False | None | None | False | None | False | 11136.0 | 0 | 3937192 | 152179 | None | code282 | Providing and fixing on wall surface unplasticised Rigid rain water pipes confirming to IS:13592 Type A, including jointing with seal ring confirming to IS:5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes 100mm diameter. Ground floor to First floor complete with all lead and lift as per the direction of Engineer-In-Charge | Mtr | 291.0 | 291.0 | 200.0 | False | None | None | False | None | False | 58200.0 | 0 | 3937193 | 152179 | None | code283 | Providing and fixing on wall surface unplasticised Rigid rain water pipes confirming to IS:13592 Type A, including jointing with seal ring confirming to IS:5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes 100mm diameter. first floor to Third complete with all lead and lift as per the direction of Engineer-In-Charge | Mtr | 291.0 | 291.0 | 100.0 | False | None | None | False | None | False | 29100.0 | 0 | 3937194 | 152179 | None | code284 | Providing and fixing on wall surface unplasticised Rigid rain water pipes confirming to IS:13592 Type A, including jointing with seal ring confirming to IS:5382, leaving 10mm gap for thermal expansion, (i) Single socketed pipes 100mm diameter. third floor to terrace complete with all lead and lift as per the direction of Engineer-In-Charge | Mtr | 291.0 | 291.0 | 100.0 | False | None | None | False | None | False | 29100.0 | 0 | 3937195 | 152179 | None | code285 | Cutting holes upto 30x30cm in walls including making good the same: with common burnt clay F.P.S (non modular) bricks. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 323.0 | 323.0 | 10.0 | False | None | None | False | None | False | 3230.0 | 0 | 3937196 | 152179 | None | code286 | Cutting holes upto 30x30cm in walls including making good the same: with common burnt clay F.P.S (non modular) bricks. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 323.0 | 323.0 | 10.0 | False | None | None | False | None | False | 3230.0 | 0 | 3937197 | 152179 | None | code287 | Cutting holes upto 30x30cm in walls including making good the same: with common burnt clay F.P.S (non modular) bricks. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 323.0 | 323.0 | 40.0 | False | None | None | False | None | False | 12920.0 | 0 | 3937198 | 152179 | None | code288 | Cutting holes upto 15x15cm in RCC floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc, with cement concrete 1:2:4 (1 cement: 2 Coarse sand: 4 graded stone aggregate 20mm nominal size), including finishing complete so as to make it leak proof. Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Mtr | 2532.0 | 2532.0 | 5.0 | False | None | None | False | None | False | 12660.0 | 0 | 3937199 | 152179 | None | code289 | Cutting holes upto 15x15cm in RCC floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc, with cement concrete 1:2:4 (1 cement: 2 Coarse sand: 4 graded stone aggregate 20mm nominal size), including finishing complete so as to make it leak proof. first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Mtr | 2532.0 | 2532.0 | 5.0 | False | None | None | False | None | False | 12660.0 | 0 | 3937200 | 152179 | None | code290 | Cutting holes upto 15x15cm in RCC floors and roofs for passing drain pipe etc, and repairing the hole after insertion of drain pipe etc, with cement concrete 1:2:4 (1 cement: 2 Coarse sand: 4 graded stone aggregate 20mm nominal size), including finishing complete so as to make it leak proof. third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Mtr | 2532.0 | 2532.0 | 2.0 | False | None | None | False | None | False | 5064.0 | 0 | 3937201 | 152179 | None | code291 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 296.0 | 296.0 | 2.0 | False | None | None | False | None | False | 592.0 | 0 | 3937202 | 152179 | None | code292 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore first floor complete with all lead and lift as per the direction of Engineer-In-Charge | Nos | 150.0 | 150.0 | 2.0 | False | None | None | False | None | False | 300.0 | 0 | 3937203 | 152179 | None | code293 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 15 mm nominal bore third floor complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 164.0 | 164.0 | 2.0 | False | None | None | False | None | False | 328.0 | 0 | 3937204 | 152179 | None | code294 | Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : Size 600x450x200 mm Ground floor complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 5082.0 | 5082.0 | 2.0 | False | None | None | False | None | False | 10164.0 | 0 | 3937205 | 152179 | None | code295 | Providing and fixing of universal clamp of size 2.5 made out of mild steel including fixing with the drop in anchor and taper nut sleeve anchor complete including bolting, cost of labour and material GF to Terrace complete with all lead and lift as per the direction of Engineer-In-Charge | Each | 5082.0 | 5082.0 | 300.0 | False | None | None | False | None | False | 1524600.0 | 0 | 3937206 | 152179 | None | code296 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) | Mtr | 1184.0 | 1184.0 | 450.0 | False | None | None | False | None | False | 532800.0 | 0 | 3937207 | 152179 | None | code297 | Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. | Mtr | 1933.0 | 1933.0 | 200.0 | False | None | None | False | None | False | 386600.0 | 0 | 3937208 | 152179 | None | code298 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments | Mtr | 150.0 | 150.0 | 1.0 | False | None | None | False | None | False | 150.0 | 0 | 3937209 | 152179 | None | code299 | Providing and laying at site of work MS casing caps as per IS 1239 (partII) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge | Mtr | 164.0 | 164.0 | 1.0 | False | None | None | False | None | False | 164.0 | 0 |
| 1725625659000 | 0 | None | None | Buildings | CONSTRUCTION OF PANDAVAPURA SUB OFFICE FOR MANMUL MANDYA DISTRICT ELECTRICAL | 5589101.1 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3937210 | 152180 | None | code01 | HT 11 kV HT Metering cubicle of different CT Ratio, Both side cable entry type with 3 CT & 3 PT, With Transparent Cover TTB, with 30x8 mm Copper Busbar, Modem & 2 No of Meters for 3 Phase 4 Wire Metering without Load Break Switch (HT Metering Box Fabricated out of 3 mm MS Sheet duly epoxy powder coated) as per revised Specification (Dwg No. BESCOM/GM/QS&S/-- Dtd 24.11.2018) | No | 243472.0 | 243472.0 | 1.0 | False | None | None | False | None | False | 243472.0 | 0 | 3937211 | 152180 | None | code02 | Supply, erection, testing and commissioning of ...250.. KVA 5 Star rated Aluminium/Copper wound Distribution Transformer 11KV/433V with Off Load Tap Switch, Buchholtz relay winding temperature indicator, oil temperature indicator, marshalling box with wiring, oil level indicator with + 5% to -10% Steps of 2.5%, HT and LT Cable Entry Box Type, stacked core with oil as per IS:1180(Part-1):2014 with all standard accessories as per latest IS standard No:2026/1977 and IS:335, technical specification & ESCOM 250 KVA - Aluminium Wound | No | 441717.0 | 441717.0 | 1.0 | False | None | None | False | None | False | 441717.0 | 0 | 3937212 | 152180 | None | code03 | HT Cable Group A Supplying & Laying of High Tension 11kVCable Dry Curing & Dry Cooling With true triple Extrusion , Simltaneously Through a Single Common head 3Core under Ground XLPE ( E ) Cable having stranded Compact Circular Aluminium Conductor , Screened insulated , insulation screened with extruded semiconducting compound in combination with copper tape core laid up extruded inner shelthed of GI flat strip armoured and over all PVC Sheathed with Specified IS 7098 / 11 /85 with latest amendments & confirming to the GTP of Group -A | Mtr | 1380.0 | 1380.0 | 140.0 | False | None | None | False | None | False | 193200.0 | 0 | 3937213 | 152180 | None | code04 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated, PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 3.5 core 95 sqmm. | Km | 373215.0 | 373215.0 | 0.1 | False | None | None | False | None | False | 37321.5 | 0 | 3937214 | 152180 | None | code05 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire
powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2. 12way | No | 15529.0 | 15529.0 | 1.0 | False | None | None | False | None | False | 15529.0 | 0 | 3937215 | 152180 | None | code06 | Supplying heavy gauge PVC conduit pipe ……dia…..mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall /stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 19/20mm dia 2mm thick | Mtr | 69.0 | 69.0 | 950.0 | False | None | None | False | None | False | 65550.0 | 0 | 3937216 | 152180 | None | code07 | Supplying heavy gauge PVC conduit pipe ……dia…..mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall /stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25mm dia 2mm thick | Mtr | 81.0 | 81.0 | 1800.0 | False | None | None | False | None | False | 145800.0 | 0 | 3937217 | 152180 | None | code08 | Supplying PVC/GI flexible conduit pipe….mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely. 20mm | Mtr | 19.0 | 19.0 | 500.0 | False | None | None | False | None | False | 9500.0 | 0 | 3937218 | 152180 | None | code09 | Supplying PVC/GI flexible conduit pipe….mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely. 25mm | Mtr | 22.0 | 22.0 | 500.0 | False | None | None | False | None | False | 11000.0 | 0 | 3937219 | 152180 | None | code10 | Supplying heavy gauge PVC conduit pipe …….dia .......mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall / stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval
of 700mm using NF screws. . 32mm dia 2.5mm thick | Mtr | 106.0 | 106.0 | 400.0 | False | None | None | False | None | False | 42400.0 | 0 | 3937220 | 152180 | None | code11 | Supplying push button operated direct online starter with an antiweld silver cadmium oxide contactor with replaceable fixed and moving contacts and bimetallic thermal overload relay help in anticorrosion treated sheet or iron clad enclosure and fixing the same to suitable capacity wires for 400/440 volts 3 phase motor/single phase motor upto 5 HP | Each | 1927.0 | 1927.0 | 2.0 | False | None | None | False | None | False | 3854.0 | 0 | 3937221 | 152180 | None | code12 | Supplying fully automatic star-delta starter unit push button type with suitable wires, 3 contactors, one adjustable thermal timer mounted on a common base plate held in steel enclosure for use on 400/440 volts 3 phase and wired after fixing to the existing wooden board for motor. | Each | 7455.0 | 7455.0 | 2.0 | False | None | None | False | None | False | 14910.0 | 0 | 3937222 | 152180 | None | code13 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuitwith adjustable thermal magnetic release, Micro processor release shall have Earth Fault as per IS/IEC 60947-2 .(Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism | Each | 24626.0 | 24626.0 | 3.0 | False | None | None | False | None | False | 73878.0 | 0 | 3937223 | 152180 | None | code14 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 5-32 Amps SP | Each | 415.0 | 415.0 | 70.0 | False | None | None | False | None | False | 29050.0 | 0 | 3937224 | 152180 | None | code15 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 40 Amps SP | Each | 739.0 | 739.0 | 20.0 | False | None | None | False | None | False | 14780.0 | 0 | 3937225 | 152180 | None | code16 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. 4 Way TP & N | Each | 4038.0 | 4038.0 | 8.0 | False | None | None | False | None | False | 32304.0 | 0 | 3937226 | 152180 | None | code17 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. 6Way TP &N | Each | 4940.0 | 4940.0 | 8.0 | False | None | None | False | None | False | 39520.0 | 0 | 3937227 | 152180 | None | code18 | Supplying, fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based, digital readout of percentage leakage current, programmable delay/auto/ manual reset facility suitable to mount on DIN rail/ flush mounting on panel board. | Each | 9255.0 | 9255.0 | 10.0 | False | None | None | False | None | False | 92550.0 | 0 | 3937228 | 152180 | None | code19 | Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB ). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely. 20Amps | Each | 971.0 | 971.0 | 25.0 | False | None | None | False | None | False | 24275.0 | 0 | 3937229 | 152180 | None | code20 | Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB ). The entire plug and socket shall be mounted in a thermoplastic / powder coated metal box & wired Completely. 30Amps | Each | 1700.0 | 1700.0 | 40.0 | False | None | None | False | None | False | 68000.0 | 0 | 3937230 | 152180 | None | code21 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box,the other end of the wires shall be terminated with sufficient looselength in a wood/PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box | Point | 269.0 | 269.0 | 400.0 | False | None | None | False | None | False | 107600.0 | 0 | 3937231 | 152180 | None | code22 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box,the other end of the wires shall be terminated with sufficient looselength in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch box | Point | 379.0 | 379.0 | 180.0 | False | None | None | False | None | False | 68220.0 | 0 | 3937232 | 152180 | None | code23 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral)& 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box,the other end of the wires shall be terminated with sufficient looselength in a wood/PVC round block. complete for each outlet. Long point above 6Mtr upto 10Mtr from tapping point to outlet via switch box | Point | 555.0 | 555.0 | 70.0 | False | None | None | False | None | False | 38850.0 | 0 | 3937233 | 152180 | None | code24 | Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 sqmm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet. Two outlet in a row, above 3Mtr upto 6Mtr from tapping point to outlet via switchs. | Point | 677.0 | 677.0 | 180.0 | False | None | None | False | None | False | 121860.0 | 0 | 3937234 | 152180 | None | code25 | Supplying and wiring adopting loop system in existing PVC Conduit / casing capping using 1100V grade, COPPER conductor flexible multistrand FRLS PVC insulated, 2x1.5 sqmm Cable confirming to the GTP without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block complete for each outlet.Two outlet in a rowThree above 6Mtr upto 10Mtr from tapping point to outlet via switchs box | Point | 989.0 | 989.0 | 30.0 | False | None | None | False | None | False | 29670.0 | 0 | 3937235 | 152180 | None | code26 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.4 sqmm | Mtr | 63.0 | 63.0 | 500.0 | False | None | None | False | None | False | 31500.0 | 0 | 3937236 | 152180 | None | code27 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmm | Mtr | 92.0 | 92.0 | 750.0 | False | None | None | False | None | False | 69000.0 | 0 | 3937237 | 152180 | None | code28 | Supplying 6A flush type socket and 6 amps flush type SP switch either surface or flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654 | Each | 128.0 | 128.0 | 400.0 | False | None | None | False | None | False | 51200.0 | 0 | 3937238 | 152180 | None | code29 | Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. 16Combined switch and socket with indication. 32A Bakelite DP | Each | 232.0 | 232.0 | 80.0 | False | None | None | False | None | False | 18560.0 | 0 | 3937239 | 152180 | None | code30 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5 Way | Each | 177.0 | 177.0 | 150.0 | False | None | None | False | None | False | 26550.0 | 0 | 3937240 | 152180 | None | code31 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module | Each | 161.0 | 161.0 | 280.0 | False | None | None | False | None | False | 45080.0 | 0 | 3937241 | 152180 | None | code32 | Supplying and fixing of modular switch/socket/stepped electronic fan regulator or dimmer or telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 | Each | 166.0 | 166.0 | 220.0 | False | None | None | False | None | False | 36520.0 | 0 | 3937242 | 152180 | None | code33 | Supplying and fixing of modular switch/socket/stepped electronic fan regulator or dimmer or telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 16Amps one way switch | Each | 180.0 | 180.0 | 140.0 | False | None | None | False | None | False | 25200.0 | 0 | 3937243 | 152180 | None | code34 | Supplying and fixing of modular switch/socket/stepped electronic fan regulator or dimmer or telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 TV/Television socket | Each | 156.0 | 156.0 | 15.0 | False | None | None | False | None | False | 2340.0 | 0 | 3937244 | 152180 | None | code35 | Supplying and fixing of modular switch/socket/stepped electronic fan regulator or dimmer or telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 RJ45/ I.O. outlet | Each | 337.0 | 337.0 | 30.0 | False | None | None | False | None | False | 10110.0 | 0 | 3937245 | 152180 | None | code36 | Supplying and fixing of metal clad industrial plugs and sockets 2pole+earth 250V | Each | 387.76 | 387.76 | 180.0 | False | None | None | False | None | False | 69796.8 | 0 | 3937246 | 152180 | None | code37 | Supplying and fixing of metal clad industrial plugs and sockets 3pole+earth 440V | Each | 609.86 | 609.86 | 230.0 | False | None | None | False | None | False | 140267.8 | 0 | 3937247 | 152180 | None | code38 | Supplying, erecting, testing & commissioning of ON-LINE UPS system suitable for operation on 230V, 50Hz, A/C supply, with all accessories complete and Excluding batteries and wiring complete. | Each | 103570.0 | 103570.0 | 1.0 | False | None | None | False | None | False | 103570.0 | 0 | 3937248 | 152180 | None | code39 | Supplying, installation, testing & commissioning of 12V DC,AH batteries in poly propylene container for U.P.S. Sealed maintenance free batteries. 75 / 80 AH capacity | Each | 17409.0 | 17409.0 | 10.0 | False | None | None | False | None | False | 174090.0 | 0 | 3937249 | 152180 | None | code40 | Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame. | Each | 707.0 | 707.0 | 20.0 | False | None | None | False | None | False | 14140.0 | 0 | 3937250 | 152180 | None | code41 | Supplying and Drawing PVC flexible one Pair telephone Unarmoured tinned Copper Cable | Mtr | 46.0 | 46.0 | 300.0 | False | None | None | False | None | False | 13800.0 | 0 | 3937251 | 152180 | None | code42 | Supplying and fixing 2mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required. 150x50mm | Mtr | 463.0 | 463.0 | 70.0 | False | None | None | False | None | False | 32410.0 | 0 | 3937252 | 152180 | None | code43 | Supplying and fixing 2mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required.300x50mm | Mtr | 587.0 | 587.0 | 90.0 | False | None | None | False | None | False | 52830.0 | 0 | 3937253 | 152180 | None | code44 | Supplying and fixing 2mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required.450x50mm | Mtr | 913.0 | 913.0 | 20.0 | False | None | None | False | None | False | 18260.0 | 0 | 3937254 | 152180 | None | code45 | Supplying and fixing 2mm thick perforated cable GI tray with on existing MS angle support using necessary GI bolts/nuts and washer or welding as required.600x50mm | Mtr | 938.0 | 938.0 | 40.0 | False | None | None | False | None | False | 37520.0 | 0 | 3937255 | 152180 | None | code46 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts. | No | 4256.0 | 4256.0 | 5.0 | False | None | None | False | None | False | 21280.0 | 0 | 3937256 | 152180 | None | code47 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI | Mtr | 82.0 | 82.0 | 200.0 | False | None | None | False | None | False | 16400.0 | 0 | 3937257 | 152180 | None | code48 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI 25x6mm GI | Mtr | 128.0 | 128.0 | 100.0 | False | None | None | False | None | False | 12800.0 | 0 | 3937258 | 152180 | None | code49 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. GI 50x6mm GI | Mtr | 218.0 | 218.0 | 100.0 | False | None | None | False | None | False | 21800.0 | 0 | 3937259 | 152180 | None | code50 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required 50x6mm CU | Mtr | 2169.0 | 2169.0 | 30.0 | False | None | None | False | None | False | 65070.0 | 0 | 3937260 | 152180 | None | code51 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required 25x6mm CU | Mtr | 1100.0 | 1100.0 | 70.0 | False | None | None | False | None | False | 77000.0 | 0 | 3937261 | 152180 | None | code52 | Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.(MIRROR LIGHT). LED light fitting 1 x 4' - 36/40 W | Each | 1269.0 | 1269.0 | 60.0 | False | None | None | False | None | False | 76140.0 | 0 | 3937262 | 152180 | None | code53 | Supply of LED pole mounting type post top lantern with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/ clear glass material, delivering superior light output.Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB . LED Efficiency130lm/w, nominal CRI 75. Luminaire manufacturer should have inhouse facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/umileds/Osram make LED Source. LED Post Top Lantern with 35/40 W | No | 9622.0 | 9622.0 | 5.0 | False | None | None | False | None | False | 48110.0 | 0 | 3937263 | 152180 | None | code54 | Design, supplying, erecting testing and commissioning of - passenger/ Bed-cum-passenger hospital lift with speed of 1mtr per second, variable voltage variable frequency drive, with or without machine room for the available well size, operating at 415 V 3 phase 50 cycles AC supply, powder coated / Stainless Steel car entrance doors enclosures with suitable colour vinyl flooring, LED car illumination, emergency light, intercom and fan as desired by the user, central opening / side opening door with or without attendant operation, 7 segment display buttons, call register indicator, fireman drive, SS handrails inside car, full length infrared curtain in car door, automatic rescue device with batteries, voice announcing in regional / international languages, Braille buttons with one year warranty and maintenance with necessary scaffolding and minor civil works like fixing of guide rail, counter weight etc.,With machine room-PC Finish---8 Passenger elevator is geared equipment Capacity--3 stops | No | 1302459.0 | 1302459.0 | 1.0 | False | None | None | False | None | False | 1302459.0 | 0 | 3937264 | 152180 | None | code55 | Supplying, installing, testing and commissioning of Diesel Generator set with following specifications. Power rating asper standard reference condition as per-BS 5514 / ISO 3046 /ISO 8528 & IS 1002 / ISO 3046 Generator set specifications. 100 kVA/80 kW Detailed Specification as per SR | Set | 900956.0 | 900956.0 | 1.0 | False | None | None | False | None | False | 900956.0 | 0 | 3937265 | 152180 | None | code56 | Supply, Erection, testing and commissioning of AMFpanel suitable for .....KVA DG set. The panel is of cubicaltype base/floor mounting control panel with hinged doors,undrilled bottom gland plate, aluminium Bus Bar with theaccommodation for .....amps 4 pole contactor for alternatorwith thermal O/L relay,..... Amps 4 pole contactor for mains, HRC fuse for short circuit protection, Microprocessor basedAMF module with supply failure timer, Restoration timer, 3impulse automatic engine start/stop logic, Mains/generatorvoltage, ....capacity bypass switch and frequency sensing, PCC 1301 controller with water temperature/Lube oilpressure/ engine speed, Voltage/ampere/Frequency/ KVA,Running-hour count, No of starts, Fault indication, over /under speed, Fails to start, Low oil pleasure, High enginetemperature, Under/over voltage, over current, Earth faultrelay, with indications for Mains on, Load on Mains, Battery charger on Push buttons AMf module by pass Mode, Batterycharger unit with inbuilt Auto/Manual and Flat/Boost facility. 125 KVA | Set | 109531.0 | 109531.0 | 1.0 | False | None | None | False | None | False | 109531.0 | 0 |
|
|
---|