1725796936000 | 0 | None | None | Other Works | Construction of tank in SWM site for convertion of wet waste to compost | 1354834.5 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3940842 | 152455 | None | ITEMCODE001 | Earth work emultiplycavation for Foundation by mechanical means for all worksand depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of emultiplycavated surfaces, disposing off or levelling the emultiplycavated earth or sortingand stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machineryand other appurtenaces required to complete the work-In all kinds of soils Depth upto 3 m (Vol-1, I. no 1.14.1and Pg no -8) | Cum | 114.24 | 114.24 | 107.324 | False | None | None | False | None | False | 12260.69376 | 0 | 3940843 | 152455 | None | ITEMCODE002 | Removal of Unserviceable Soil with Disposal up to a suitable distance as directed by the Engineer in charge of work Vol:3 P.NO. 17 I.No: 3.1) | Cum | 95.2 | 95.2 | 107.324 | False | None | None | False | None | False | 10217.2448 | 0 | 3940844 | 152455 | None | ITEMCODE003 | Providing and Filling in foundation with granite or trap broken metal 100mm and down size with approved M-Sand including hand packing, ramming, watering including cost of all materials and labour with all lead and lift complete as per specifications(Vol-1 I.no-1..23and Pg No -11 | Cum | 3003.84 | 3003.84 | 22.95 | False | None | None | False | None | False | 68938.128 | 0 | 3940845 | 152455 | None | ITEMCODE004 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite or trap or basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mimultiplyed, laid in layers not emultiplyceeding 150 mm thickness, well compacted using plate vibrators, including all leadand lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcementand formwork shall be paid separately) -Mimultiply 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates (Vol-1, I. no 2.1.3and Pg no -15) | Cum | 6707.68 | 6707.68 | 7.649 | False | None | None | False | None | False | 51307.04432 | 0 | 3940846 | 152455 | None | ITEMCODE005 | Providing, laying, spreading and compacting graded stone aggregate to wet mimultiply macadam specification including premimultiplying the Material with water at OMC in mechanical mimultiply plant carriage of mimultiplyed Material by tipper to site, laying in uniform layers with paver or grader in sub-base or base course on well prepared surface and compacting with vibratory roller to achieve the desired density. (Vol -3 I.no- 4.17and Pg No-26) | Cum | 2866.08 | 2866.08 | 13.175 | False | None | None | False | None | False | 37760.604 | 0 | 3940847 | 152455 | None | ITEMCODE006 | Providing and laying in Reinforced cement concrete for all Basement& surface level works, return walls, retaining walls, sunken floors etc. The granite or trap or basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mimultiplyed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all leadand lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcementand formwork to be paid separately) -M20 Design Mimultiply Using 20 mm nominal size graded crushed coarse aggregates (Vol-1, I. no 2.4.2and Pg no -16) | Cum | 7081.76 | 7081.76 | 24.212 | False | None | None | False | None | False | 171463.57312 | 0 | 3940848 | 152455 | None | ITEMCODE007 | Form work as per recommendation of technic working groupe rate for formwork shall be added on Percentage basis to the finished rate of concrete per meter cube for Earth retaining structures Centering 10% (vol-1-Sl No.11 Pg.no-112) | Cum | 708.17 | 708.17 | 24.212 | False | None | None | False | None | False | 17146.21204 | 0 | 3940849 | 152455 | None | ITEMCODE008 | Filling approved earth (emultiplycluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not emultiplyceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (Vol-1, I. no 1.11and Pg no -7) | Cum | 484.96 | 484.96 | 64.824 | False | None | None | False | None | False | 31437.04704 | 0 | 3940850 | 152455 | None | ITEMCODE009 | Supplying, fitting and placing TMT FE 550 or 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping or welding joints, tying with binding wire or soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 100191.84 | 100191.84 | 2.924 | False | None | None | False | None | False | 292960.94016 | 0 | 3940851 | 152455 | None | ITEMCODE010 | Providing and fimultiplying Unplasticised Polyvinyl Chloride (uPVC) pipes, for cold water supply including all uPVC plainand brass threaded fittings This includes jointing of pipesand fittings with one step uPVC solvent cement, trenching, refillingand testing of joints complete as per direction of Engineer in Charge. Emultiplyternal work (CSR -23-24,Vol-2, Page No.125 Item No.13.50.10 ) | m | 1784.16 | 1784.16 | 3.75 | False | None | None | False | None | False | 6690.6 | 0 | 3940852 | 152455 | None | ITEMCODE011 | Providing and fimultiplying Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hotand cold water supply, including all CPVC plainand brass threaded fittings, including fimultiplying the pipe with clamps at 1.00 m spacing. This includes jointing of pipesand fittings with one step CPVC solvent cement and testing of joints complete as per direction of
Engineer in Charge. Internal work - Emultiplyposed on wall -50 mm nominal dia Pipes CSR -23-24,Vol-2, Page No.122 Item No.13.31.6 ) | m | 600.31 | 600.31 | 30.0 | False | None | None | False | None | False | 18009.3 | 0 | 3940853 | 152455 | None | ITEMCODE012 | Providing and fimultiplying Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hotand cold water supply, including all CPVC plainand brass threaded fittings, including fimultiplying the pipe with clamps at 1.00 m spacing. This includes jointing of pipesand fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Emultiplyposed on wall -20 mm nominal dia Pipes CSR -23-24,Vol-2, Page No.122 Item No.13.31.2 ) | m | 271.04 | 271.04 | 12.0 | False | None | None | False | None | False | 3252.48 | 0 | 3940854 | 152455 | None | ITEMCODE013 | Providing and fimultiplying MS ladder between landings, 45 cms wide using angle iron of specified sizes, 20mm MS bars at 25 cms. centre to centre, with necessary supports of same angle iron etc. as directed, including hand railing on both sides with 25mm dia. GI pipes with angle iron props at 2 mtrs. intervals and 0.5M heigh, including fimultiplying in ground with CC 1:2:4 and two coats of anticorrosive bituminous paint etc. with all lead and lifts etc. complete with:MS angle of 65 multiply 65 multiply 10mm (CSR -23-24,Vol-2, Page No.7.1.1 Item No.85) | m | 4902.24 | 4902.24 | 6.3 | False | None | None | False | None | False | 30884.112 | 0 | 3940855 | 152455 | None | ITEMCODE014 | Providingand fimultiplying corrugated G.S. sheet roofing including vertical or curved surface fimultiplyed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal or vertical or curved surfaces), emultiplycluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per the direction of Engineer in charge 0.63 mm thick with zinc coating not less than 275 g or m²(Vol-2 I.no-7.1.1and Pg No - 21) | Sqm | 984.48 | 984.48 | 108.0 | False | None | None | False | None | False | 106323.84 | 0 | 3940856 | 152455 | None | ITEMCODE015 | Providingand fimultiplying ridges or hips of width 60 cm overall width plain G.S. sheet fimultiplyed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete as per design drawings 0.63 mm thick with zinc coating not less than 275 g or m² ( Vol-2 I.no-7.4and Pg No - 21) | m | 715.68 | 715.68 | 9.0 | False | None | None | False | None | False | 6441.12 | 0 | 3940857 | 152455 | None | ITEMCODE016 | Providingand fimultiplying flat iron brackets 50multiply3 mm size with necessary bolts, nuts and washers etc. for fimultiplying G.S. sheets gutters with purlins.( Vol-2 I.no-7.13and Pg No - 22) | m | 82.88 | 82.88 | 18.0 | False | None | None | False | None | False | 1491.84 | 0 | 3940858 | 152455 | None | ITEMCODE017 | Providing and fimultiplying Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fimultiplying in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Vol-2 I.no-11.16.2and Pg No - 82) | Kgs | 164.64 | 164.64 | 2737.892 | False | None | None | False | None | False | 450766.53888 | 0 | 3940859 | 152455 | None | ITEMCODE018 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. Waste water pump ( Vol-5 I.no-13.40.1and Pg No - 157) | Each | 17483.2 | 17483.2 | 1.0 | False | None | None | False | None | False | 17483.2 | 0 | 3940860 | 152455 | None | ITEMCODE019 | Providingand fimultiplying Electric works such wiring, light as per site requirements | No | 20000.0 | 20000.0 | 1.0 | False | None | None | False | None | False | 20000.0 | 0 |
|