3657236 | 133410 | None | 001 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m Complete with all lead and lifts as directed by engineer-in-charge. | Cum | 126.37 | 126.37 | 167.33 | False | None | None | False | None | False | 21145.4921 | 0 |
3657237 | 133410 | None | 002 | Earth work in surface excavation by mechanical means for lowering &leveling the ground for all works other than foundation in all kinds ofsoils & upto depth not exceeding 300mm as per drawing and technicalspecifications, including setting out, shoring, strutting,barricading,caution lights, removal of stumps and other deleterious matter includingdressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radiusof 50 m and lift upto 1.5 m including cost of labour, tools, usage ofmachinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth Complete with all lead and lifts as directed by engineer-in-charge. | Cum | 117.7 | 117.7 | 54.08 | False | None | None | False | None | False | 6365.216 | 0 |
3657238 | 133410 | None | 003 | Providing and Filling in foundation with granite / trap broken metal 100mm. and down size & with approved sand including hand packing, ramming, watering, including cost of all materials and labour with all lead and lift complete as per specifications. Complete with all lead and lifts as directed by engineer-in-charge. | Cum | 3322.99 | 3322.99 | 43.76 | False | None | None | False | None | False | 145414.0424 | 0 |
3657239 | 133410 | None | 004 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates Complete with all lead and lifts as directed by engineer-in-charge. | Cum | 7420.37 | 7420.37 | 46.03 | False | None | None | False | None | False | 341559.6311 | 0 |
3657240 | 133410 | None | 005 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Complete with all lead and lifts as directed by engineer-in-charge. | Cum | 7789.59 | 7789.59 | 22.3 | False | None | None | False | None | False | 173707.857 | 0 |
3657241 | 133410 | None | 006 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Additionalities for Formwork, (a.Isolated @ 8%) Complete with all lead and lifts as directed by engineer-in-charge. | Cum | 623.16 | 623.16 | 22.3 | False | None | None | False | None | False | 13896.468 | 0 |
3657242 | 133410 | None | 007 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Complete with all lead and lifts as directed by engineer-in-charge. | Cum | 7834.19 | 7834.19 | 11.77 | False | None | None | False | None | False | 92208.4163 | 0 |
3657243 | 133410 | None | 008 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Additionalities for Formwork, (staircase and other similar structures @ 50%) Complete with all lead and lifts as directed by engineer-in-charge.. | Cum | 3917.09 | 3917.09 | 6.85 | False | None | None | False | None | False | 26832.0665 | 0 |
3657244 | 133410 | None | 009 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Additionalities for Formwork, (RCC Columns / Shaft (Slip Centering) @ 70%) Complete with all lead and lifts as directed by engineer-in-charge. | Cum | 5483.93 | 5483.93 | 4.92 | False | None | None | False | None | False | 26980.9356 | 0 |
3657245 | 133410 | None | 010 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Complete with all lead and lifts as directed by engineer-in-charge. | Cum | 8214.57 | 8214.57 | 63.27 | False | None | None | False | None | False | 519735.8439 | 0 |
3657246 | 133410 | None | 011 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Additionalities for Formwork, (RCC Columns / Shaft (Slip Centering) @ 70%) Complete with all lead and lifts as directed by engineer-in-charge. | Cum | 5750.19 | 5750.19 | 5.91 | False | None | None | False | None | False | 33983.6229 | 0 |
3657247 | 133410 | None | 012 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Additionalities for Formwork, ( RCC Beams, Lintels & Troughs of Aqueducts @ 60%) Complete with all lead and lifts as directed by engineer-in-charge. | Cum | 4928.74 | 4928.74 | 51.18 | False | None | None | False | None | False | 252252.9132 | 0 |
3657248 | 133410 | None | 013 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Additionalities for Formwork, ( RCC Roof Slabs @ 50%) Complete with all lead and lifts as directed by engineer-in-charge. | Cum | 4107.28 | 4107.28 | 5.46 | False | None | None | False | None | False | 22425.7488 | 0 |
3657249 | 133410 | None | 014 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Additionalities for Formwork, ( Chejjas, Canopy & Other Architectural projections of
minor sections @ 45%) Complete with all lead and lifts as directed by engineer-in-charge. | Cum | 3696.55 | 3696.55 | 0.72 | False | None | None | False | None | False | 2661.516 | 0 |
3657250 | 133410 | None | 015 | Providing Coursed rubble masonry (first sort) with hard stone in foundation and plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) Complete with all lead and lifts as directed by engineer-in-charge. | Cum | 8199.7 | 8199.7 | 20.21 | False | None | None | False | None | False | 165715.937 | 0 |
3657251 | 133410 | None | 016 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. Deduct 5 Percentage per Cum if rollers are not used and tamping is done manually. Complete with all lead and lifts as directed by engineer-in-charge | Cum | 587.28 | 587.28 | 73.16 | False | None | None | False | None | False | 42965.4048 | 0 |
3657252 | 133410 | None | 017 | Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. a. Buildings Complete with all lead and lifts as directed by engineer-in-charge. | t | 110837.22 | 110837.22 | 11.13 | False | None | None | False | None | False | 1233618.2586 | 0 |
3657253 | 133410 | None | 018 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates Complete with all lead and lifts as directed by engineer-in-charge. | Cum | 7702.86 | 7702.86 | 0.31 | False | None | None | False | None | False | 2387.8866 | 0 |
3657254 | 133410 | None | 019 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 9873.59 | 9873.59 | 49.35 | False | None | None | False | None | False | 487261.6665 | 0 |
3657255 | 133410 | None | 020 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Complete with all lead and lifts as directed by engineer-in-charge. | Kg | 208.15 | 208.15 | 425.25 | False | None | None | False | None | False | 88515.7875 | 0 |
3657256 | 133410 | None | 021 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 8 mm thickness (weight not less than 20 kg/ m²) including cost of materials, labour, usage charges of machinery Complete with all lead and lifts as directed by engineer-in-charge. | Sqm | 1616.89 | 1616.89 | 20.25 | False | None | None | False | None | False | 32742.0225 | 0 |
3657257 | 133410 | None | 022 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery Complete with all lead and lifts as directed by engineer-in-charge. | Sqm | 3262.28 | 3262.28 | 5.0 | False | None | None | False | None | False | 16311.4 | 0 |
3657258 | 133410 | None | 023 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing Complete with all lead and lifts as directed by engineer-in-charge. | Sqm | 459.66 | 459.66 | 222.53 | False | None | None | False | None | False | 102288.1398 | 0 |
3657259 | 133410 | None | 024 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing Complete with all lead and lifts as directed by engineer-in-charge. | Sqm | 315.94 | 315.94 | 242.67 | False | None | None | False | None | False | 76669.1598 | 0 |
3657260 | 133410 | None | 025 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement: 3 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing Complete with all lead and lifts as directed by engineer-in-charge. | Sqm | 261.42 | 261.42 | 283.98 | False | None | None | False | None | False | 74238.0516 | 0 |
3657261 | 133410 | None | 026 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth Complete with all lead and lifts as directed by engineer-in-charge. | Sqm | 123.9 | 123.9 | 526.66 | False | None | None | False | None | False | 65253.174 | 0 |
3657262 | 133410 | None | 027 | Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing Complete with all lead and lifts as directed by engineer-in-charge. | Sqm | 6601.39 | 6601.39 | 19.98 | False | None | None | False | None | False | 131895.7722 | 0 |
3657263 | 133410 | None | 028 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 600x600 mm. Complete with all lead and lifts as directed by engineer-in-charge. | Sqm | 1533.88 | 1533.88 | 173.2 | False | None | None | False | None | False | 265668.016 | 0 |
3657264 | 133410 | None | 029 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 157.35 | 157.35 | 376.59 | False | None | None | False | None | False | 59256.4365 | 0 |
3657265 | 133410 | None | 030 | Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labourComplete with all lead and lifts as directed by engineer-in-charge. | Sqm | 215.58 | 215.58 | 239.18 | False | None | None | False | None | False | 51562.4244 | 0 |
3657266 | 133410 | None | 031 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour Complete with all lead and lifts as directed by engineer-in-charge. | Sqm | 61.95 | 61.95 | 11.25 | False | None | None | False | None | False | 696.9375 | 0 |
3657267 | 133410 | None | 032 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour Complete with all lead and lifts as directed by engineer-in-charge. | Sqm | 142.48 | 142.48 | 29.25 | False | None | None | False | None | False | 4167.54 | 0 |
3657268 | 133410 | None | 033 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, Complete with all lead and lifts as directed by engineer-in-charge. | Sqm | 700.03 | 700.03 | 77.76 | False | None | None | False | None | False | 54434.3328 | 0 |
3657269 | 133410 | None | 034 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, Complete with all lead and lifts as directed by engineer-in-charge. | Sqm | 1533.88 | 1533.88 | 8.3 | False | None | None | False | None | False | 12731.204 | 0 |
3657270 | 133410 | None | 035 | Providing and fixing Screws approved Nails and screws of sizes for structural glazing /ACP Cladding ( Material Components P.No - A28 I.No 548 ) Complete with all lead and lifts as directed by engineer-in-charge. | Kg | 83.01 | 83.01 | 6.0 | False | None | None | False | None | False | 498.06 | 0 |
3657271 | 133410 | None | 036 | Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary19/20mm dia 2mm thick Complete with all lead and lifts as directed by engineer-in-charge. | Mtr | 77.88 | 77.88 | 120.0 | False | None | None | False | None | False | 9345.6 | 0 |
3657272 | 133410 | None | 037 | Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary25mm dia 2mm thick Complete with all lead and lifts as directed by engineer-in-charge. | Mtr | 92.04 | 92.04 | 50.0 | False | None | None | False | None | False | 4602.0 | 0 |
3657273 | 133410 | None | 038 | Supplying heavy gauge PVC Conduit Pipe dia.mm thick with suitable size bends, metal junction boxes adhesive paste etc.,by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run through out the conduit wherever necessary.19/20mm dia 2mm thickComplete with all lead and lifts as directed by engineer-in-charge. | Mtr | 80.24 | 80.24 | 40.0 | False | None | None | False | None | False | 3209.6 | 0 |
3657274 | 133410 | None | 039 | supplying heavy gauge PVC Conduit Pipe dia mm thick with suitable size bends, metal junction boxes adhesive paste etc.,by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run through out the conduit wherever necessary.25mm dia 2mm thickComplete with all lead and lifts as directed by engineer-in-charge. | Mtr | 93.22 | 93.22 | 20.0 | False | None | None | False | None | False | 1864.4 | 0 |
3657275 | 133410 | None | 040 | Supplying and fixing sheet metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.200x90x65mmComplete with all lead and lifts as directed by engineer-in-charge. | Each | 211.22 | 211.22 | 2.0 | False | None | None | False | None | False | 422.44 | 0 |
3657276 | 133410 | None | 041 | Supplying and fixing PVC/metal conduit accessories Deep junction box.19/20mm deep junction box Complete with all lead and lifts as directed by engineer-in-charge. | Each | 57.82 | 57.82 | 10.0 | False | None | None | False | None | False | 578.2 | 0 |
3657277 | 133410 | None | 042 | Supplying and fixing PVC/metal conduit accessories Deep junction box.25mm deep junction box Complete with all lead and lifts as directed by engineer-in-charge. | Each | 66.08 | 66.08 | 25.0 | False | None | None | False | None | False | 1652.0 | 0 |
3657278 | 133410 | None | 043 | Extra for Groove cutting in brick wall/CC floor to the suitable depth for concealing of Conduit/GI pipe and plastering, up to wall surface completeup to 50mm conduit in brick wall Complete with all lead and lifts as directed by engineer-in-charge. | Mtr | 34.22 | 34.22 | 10.0 | False | None | None | False | None | False | 342.2 | 0 |
3657279 | 133410 | None | 044 | Extra for Groove cutting in brick wall/CC floor t o the suitable depth for concealing of Conduit/GI pipe and plastering, up to wall surface completeup to 50mm conduit CC floor Complete with all lead and lifts as directed by engineer-in-charge. | Mtr | 81.42 | 81.42 | 8.0 | False | None | None | False | None | False | 651.36 | 0 |
3657280 | 133410 | None | 045 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments)without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a w ood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switch box Complete with all lead and lifts as directed by engineer-in-charge. | Point | 317.42 | 317.42 | 8.0 | False | None | None | False | None | False | 2539.36 | 0 |
3657281 | 133410 | None | 046 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments)without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a woo Complete with all lead and lifts as directed by engineer-in-charge.d/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch box | Point | 447.22 | 447.22 | 12.0 | False | None | None | False | None | False | 5366.64 | 0 |
3657282 | 133410 | None | 047 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switch box Complete with all lead and lifts as directed by engineer-in-charge. | Point | 654.9 | 654.9 | 18.0 | False | None | None | False | None | False | 11788.2 | 0 |
3657283 | 133410 | None | 048 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper wire with low conductor resistance single core cable in open or concealed system of wiring with specified IS-694:2010 & confirming to the attached GTP of GROUP -A.1.5 sqmm Complete with all lead and lifts as directed by engineer-in-charge. | Mtr | 30.68 | 30.68 | 98.0 | False | None | None | False | None | False | 3006.64 | 0 |
3657284 | 133410 | None | 049 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper wire with low conductor resistance single core cable in open or Complete with all lead and lifts as directed by engineer-in-charge.concealed system of wiring with specified IS-694:2010 & confirming to the attached GTP of GROUP -A.2.5 sqmm | Mtr | 49.56 | 49.56 | 196.0 | False | None | None | False | None | False | 9713.76 | 0 |
3657285 | 133410 | None | 050 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand Copper wire with low conductor resistance single core cable in open or concealed system of wiring with specified IS-694:2010 & confirming to the attached GTP of GROUP -A.4.0 sqmm Complete with all lead and lifts as directed by engineer-in-charge. | Mtr | 74.34 | 74.34 | 20.0 | False | None | None | False | None | False | 1486.8 | 0 |
3657286 | 133410 | None | 051 | Supplying and mounting 2 Nos. of 2 way 6 amps flush type switches either surface/flush mounted on existing gang box or in 4mm thick plastic sheet and mounted on a flush mounted wooden box and wiring as required IS 3854Complete with all lead and lifts as directed by engineer-in-charge. | Each | 200.6 | 200.6 | 2.0 | False | None | None | False | None | False | 401.2 | 0 |
3657287 | 133410 | None | 052 | Supplying and fixing/replacing of 6/16/32Amps electrical accessories on existing switch board. 6 Amps Pendant HolderComplete with all lead and lifts as directed by engineer-in-charge. | No | 83.78 | 83.78 | 25.0 | False | None | None | False | None | False | 2094.5 | 0 |
3657288 | 133410 | None | 053 | Supplying and flush mounting powder coated / galavanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3WayComplete with all lead and lifts as directed by engineer-in-charge. | Each | 187.62 | 187.62 | 2.0 | False | None | None | False | None | False | 375.24 | 0 |
3657289 | 133410 | None | 054 | Supplying and flush mounting powder coated / galavanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5Way Complete with all lead and lifts as directed by engineer-in-charge. | Each | 208.86 | 208.86 | 2.0 | False | None | None | False | None | False | 417.72 | 0 |
3657290 | 133410 | None | 055 | Supplying and flush mounting powder coated / galavanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12Way Complete with all lead and lifts as directed by engineer-in-charge. | Each | 376.42 | 376.42 | 4.0 | False | None | None | False | None | False | 1505.68 | 0 |
3657291 | 133410 | None | 056 | Supplying and flush mounting powder coated / galavanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 18 Way Complete with all lead and lifts as directed by engineer-in-charge. | Each | 477.9 | 477.9 | 1.0 | False | None | None | False | None | False | 477.9 | 0 |
3657292 | 133410 | None | 057 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 Module Complete with all lead and lifts as directed by engineer-in-charge. | Each | 189.98 | 189.98 | 3.0 | False | None | None | False | None | False | 569.94 | 0 |
3657293 | 133410 | None | 058 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.4Moudule Complete with all lead and lifts as directed by engineer-in-charge. | Each | 206.5 | 206.5 | 12.0 | False | None | None | False | None | False | 2478.0 | 0 |
3657294 | 133410 | None | 059 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10 - 12Moudule Complete with all lead and lifts as directed by engineer-in-charge. | Each | 405.92 | 405.92 | 4.0 | False | None | None | False | None | False | 1623.68 | 0 |
3657295 | 133410 | None | 060 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.18 Moudule Complete with all lead and lifts as directed by engineer-in-charge. | Each | 539.26 | 539.26 | 1.0 | False | None | None | False | None | False | 539.26 | 0 |
3657296 | 133410 | None | 061 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293., 6A One Way Switch Complete with all lead and lifts as directed by engineer-in-charge. | Each | 120.36 | 120.36 | 38.0 | False | None | None | False | None | False | 4573.68 | 0 |
3657297 | 133410 | None | 062 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293., 6A Two Way Switch Complete with all lead and lifts as directed by engineer-in-charge. | Each | 195.88 | 195.88 | 2.0 | False | None | None | False | None | False | 391.76 | 0 |
3657298 | 133410 | None | 063 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293., 6A Three Way socket Complete with all lead and lifts as directed by engineer-in-charge. | Each | 201.78 | 201.78 | 8.0 | False | None | None | False | None | False | 1614.24 | 0 |
3657299 | 133410 | None | 064 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293., Stepped Fan Regulator Two Module Complete with all lead and lifts as directed by engineer-in-charge. | Each | 421.26 | 421.26 | 10.0 | False | None | None | False | None | False | 4212.6 | 0 |
3657300 | 133410 | None | 065 | Supplying and fixing hylum brand plastic sheet 3mm thick with necessary nitches for fixing switches, regulators etc., and fixing on existing wood or metal box using N.F. screws. Complete with all lead and lifts as directed by engineer-in-charge. | Sq CM | 0.41 | 0.41 | 2400.0 | False | None | None | False | None | False | 984.0 | 0 |
3657301 | 133410 | None | 066 | Extra for supplying 4mm thick white plastic plate and covering for junction boxes of size ……mm conduit using necessary machine screws.Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 80/90 mm Complete with all lead and lifts as directed by engineer-in-charge. | No | 17.7 | 17.7 | 10.0 | False | None | None | False | None | False | 177.0 | 0 |
3657302 | 133410 | None | 067 | Extra for supplying 4mm thick white plastic plate and covering for junction boxes of size ……mm conduit using necessary machine screws.Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.110mm Complete with all lead and lifts as directed by engineer-in-charge. | No | 24.78 | 24.78 | 25.0 | False | None | None | False | None | False | 619.5 | 0 |
3657303 | 133410 | None | 068 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides ofnot more than2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.15" x 12" x 2" Complete with all lead and lifts as directed by engineer-in-charge. | Each | 237.18 | 237.18 | 1.0 | False | None | None | False | None | False | 237.18 | 0 |
3657304 | 133410 | None | 069 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides ofnot more than2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws.20" x 20" x 2.5" Complete with all lead and lifts as directed by engineer-in-charge. | Each | 384.83 | 384.83 | 1.0 | False | None | None | False | None | False | 384.83 | 0 |
3657305 | 133410 | None | 070 | Supplying &fixingof Porcelai fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.32 A Complete with all lead and lifts as directed by engineer-in-charge. | Each | 284.38 | 284.38 | 2.0 | False | None | None | False | None | False | 568.76 | 0 |
3657306 | 133410 | None | 071 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve , indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps SP Complete with all lead and lifts as directed by engineer-in-charge. | Each | 489.7 | 489.7 | 4.0 | False | None | None | False | None | False | 1958.8 | 0 |
3657307 | 133410 | None | 072 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve , indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32Amps DP Complete with all lead and lifts as directed by engineer-in-charge. | Each | 872.02 | 872.02 | 2.0 | False | None | None | False | None | False | 1744.04 | 0 |
3657308 | 133410 | None | 073 | II - Double Door Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.8 Way SP & N Complete with all lead and lifts as directed by engineer-in-charge. | Each | 2187.72 | 2187.72 | 1.0 | False | None | None | False | None | False | 2187.72 | 0 |
3657309 | 133410 | None | 074 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep (1200 mm) Regular model Complete with all lead and lifts as directed by engineer-in-charge. | Each | 3521.12 | 3521.12 | 10.0 | False | None | None | False | None | False | 35211.2 | 0 |
3657310 | 133410 | None | 075 | Supplying of ..feet PVC Batten with integrated LED tube ..W with high quality diffuser with Life of 25000 burning hours & 70 Percentage lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 20/22 W Complete with all lead and lifts as directed by engineer-in-charge. | Each | 814.2 | 814.2 | 25.0 | False | None | None | False | None | False | 20355.0 | 0 |
3657311 | 133410 | None | 076 | Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation.Lamp compartment comprising ofanti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70 Percentage, maximum light intensity should be between 60 degrees tO 70 degrees. CCT 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire IK08.Power Factor 0.9 with mains,surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage ange from 100V to 270V 50/60Hz application Compliance to IS10322/IEC 60598, LM 79 & LM80 Adherence with RoHS.UL approved MCPCB. Top access street ight with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools LED Light fixture with. W System Power consumption LED Efficiency 1301m/w nominal CR 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die ca st housing/ Body part. Warranty of 2 Years against any manufacturing defectLED Streetlight 70W Complete with all lead and lifts as directed by engineer-in-charge. | No | 7070.56 | 7070.56 | 6.0 | False | None | None | False | None | False | 42423.36 | 0 |
3657312 | 133410 | None | 077 | Supplying of recess mounting nonintegral ty ..ED w
luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clA, Power LEDs with CCT 6500 degree K CRI 70 Percentage. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79& LM 80.The lamp compartment is enclosed with anti glare opal diffuser which enhances the ighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5 Percentage of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20 Percentage, Life as per LM 79. The operating input voltage should be between 130 to 275 V BIS Approved and Tested by NABL/CPRI accredited aboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 1'x4' 34-36 W Complete with all lead and lifts as directed by engineer-in-charge. | No | 6959.64 | 6959.64 | 3.0 | False | None | None | False | None | False | 20878.92 | 0 |
3657313 | 133410 | None | 078 | Supplying & fixing of retrofit type .LED bulb . W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70 Percentage. efficacy 80 lumen per W, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5 Percentage of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20 Percentage, Life as per LM 79. The operating input voltage should be between130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.12W, 6500K Complete with all lead and lifts as directed by engineer-in-charge. | Each | 317.42 | 317.42 | 5.0 | False | None | None | False | None | False | 1587.1 | 0 |
3657314 | 133410 | None | 079 | Supplying and Fixing of........mm dia class A GI pipe bracket upto 2 ms long bent at suitable angle and fixing to this bracket 1x40/2x40 W fluorescent tube street light fitting of all capacities to GI or GI or rail or RCC pole / wall using suitable clA, bolts, and nuts and wiring using suitable capacity wires.Using 25mm dia G.I.Pipe Complete with all lead and lifts as directed by engineer-in-charge. | Each | 1154.04 | 1154.04 | 3.0 | False | None | None | False | None | False | 3462.12 | 0 |
3657315 | 133410 | None | 080 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. Complete with all lead and lifts as directed by engineer-in-charge. | Each | 191.16 | 191.16 | 3.0 | False | None | None | False | None | False | 573.48 | 0 |
3657316 | 133410 | None | 081 | Fixing all types and all capacities of fluorescent /false ceiling/spot light / CFL/ LED fittings indoor on the wall/ ceiling/rafters/girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.On wall/ ceiling / Rafter / Girders Complete with all lead and lifts as directed by engineer-in-charge. | Each | 143.96 | 143.96 | 25.0 | False | None | None | False | None | False | 3599.0 | 0 |
3657317 | 133410 | None | 082 | Fixing a ceiling / Wall mounting fan of all capacities and all types to the existing 'S'' hook with fan regulator to the existing board together with supplying and fixing 5A ceiling rose, necessary length of 23 /0.0076 inch PVC insulated twin twisted copper wire and wiring. Complete with all lead and lifts as directed by engineer-in-charge. | Each | 201.78 | 201.78 | 10.0 | False | None | None | False | None | False | 2017.8 | 0 |
3657318 | 133410 | None | 083 | Extra length of GI pipe of class B 19mm dia for down rod. Complete with all lead and lifts as directed by engineer-in-charge. | m | 232.46 | 232.46 | 10.0 | False | None | None | False | None | False | 2324.6 | 0 |
3657319 | 133410 | None | 084 | Pipe Grounding EARTHING GI Grounding pipe,B-Class,42 mm dia,2.5 Mts long,3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg Complete with all lead and lifts as directed by engineer-in-charge. | No | 876.74 | 876.74 | 1.0 | False | None | None | False | None | False | 876.74 | 0 |
3657320 | 133410 | None | 085 | Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each Complete with all lead and lifts as directed by engineer-in-charge. | No | 797.68 | 797.68 | 1.0 | False | None | None | False | None | False | 797.68 | 0 |
3657321 | 133410 | None | 086 | Good Quality Salt for grounding purposes packed in 50 Kg gunny bag Complete with all lead and lifts as directed by engineer-in-charge. | Bag | 365.8 | 365.8 | 1.0 | False | None | None | False | None | False | 365.8 | 0 |
3657322 | 133410 | None | 087 | Digging of Pit for providing GI Pipe type Earthing LABOUR RATE Ordinary Soil Complete with all lead and lifts as directed by engineer-in-charge. | Per Pit | 895.62 | 895.62 | 1.0 | False | None | None | False | None | False | 895.62 | 0 |
3657323 | 133410 | None | 088 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 10 Sqmm, 2 Core, (9 GI Strips - 4 x 0.8 mm) Complete with all lead and lifts as directed by engineer-in-charge. | Mtr | 93493.76 | 93493.76 | 0.06 | False | None | None | False | None | False | 5609.6256 | 0 |
3657324 | 133410 | None | 089 | Laying of cable in Existing Trench/GI pipe/ Stone Ware /RCC Hume pipe using Wooden /Aluminum Rollers as directed by the departmental staff LT Cable 2.5 to 25 Sqmm PER KM RATE 161597/1000=16.159mt Complete with all lead and lifts as directed by engineer-in-charge. | Mtr | 24645.48 | 24645.48 | 0.06 | False | None | None | False | None | False | 1478.7288 | 0 |
3657325 | 133410 | None | 090 | UG Cable Work ; Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits, depositing on bank upto a lead of 50 Mtr, Supplying and Displaying necessary Danger Boards and Lighting, Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed.In Ordinary Soil .5x.75.x45 = 16.88 Complete with all lead and lifts as directed by engineer-in-charge. | Cum | 306.8 | 306.8 | 16.88 | False | None | None | False | None | False | 5178.784 | 0 |
3657326 | 133410 | None | 091 | Refilling the cable trenches with selected available earth from trench excavation including watering, consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 Mtr Complete with all lead and lifts as directed by engineer-in-charge. | Cum | 68.44 | 68.44 | 16.88 | False | None | None | False | None | False | 1155.2672 | 0 |
3657327 | 133410 | None | 092 | Laying the GI Pipe 80 mm to 150 mm dia at Drainage Water Supply Crossing including fixing collars elbows, bends, Tees and other fitting with Cuts and Threads wherever necessary complete. Complete with all lead and lifts as directe | Mtr | 109.74 | 109.74 | 6.0 | False | None | None | False | None | False | 658.44 | 0 |
3657328 | 133410 | None | 093 | GI Pipe B - Class as per IS-1239 GI Pipe - 50 mm Dia Complete with all lead and lifts as directed by engineer-in-charge. | Mtr | 382.32 | 382.32 | 6.0 | False | None | None | False | None | False | 2293.92 | 0 |
3657329 | 133410 | None | 094 | Laying the GI Pipe 80 mm to 150 mm dia at Drainage Water Supply Crossing including fixing collars elbows, bends, Tees and other fitting with Cuts and Threads wherever necessary complete. Complete with all lead and lifts as directed by engineer-in-charge. | Mtr | 109.74 | 109.74 | 3.0 | False | None | None | False | None | False | 329.22 | 0 |
3657330 | 133410 | None | 095 | HDPE/PLB Pipe 50/42 mm Par KM 85014/1000 =85.014 Complete with all lead and lifts as directed by engineer-in-charge. | Km | 100316.52 | 100316.52 | 0.04 | False | None | None | False | None | False | 4012.6608 | 0 |
3657331 | 133410 | None | 096 | Guy Wire & GI Wire as per IS-2141 8 SWG GI Wire MT -77850 / 1000 =77.85 PER KG (4.064 mm Dia), Std Wt: 131 Kg/KM Complete with all lead and lifts as directed by engineer-in-charge. | MT | 88547.2 | 88547.2 | 0.01 | False | None | None | False | None | False | 885.472 | 0 |
3657332 | 133410 | None | 097 | EXTERNAL POWER SUPPLY DEPOSITS OF BESCOM COMMAN SR - 2021-2022 | Job | 7080.0 | 7080.0 | 1.0 | False | None | None | False | None | False | 7080.0 | 0 |
3657333 | 133410 | None | 098 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Complete with all lead and lifts as directed by engineer-in-charge. | Cum | 8023.28 | 8023.28 | 15.31 | False | None | None | False | None | False | 122836.4168 | 0 |
3657334 | 133410 | None | 099 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) Complete with all lead and lifts as directed by engineer-in-charge. | Cum | 7915.97 | 7915.97 | 28.74 | False | None | None | False | None | False | 227504.9778 | 0 |
3657335 | 133410 | None | 100 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Columns and piers Complete with all lead and lifts as directed by engineer-in-charge. | Cum | 13964.77 | 13964.77 | 3.85 | False | None | None | False | None | False | 53764.3645 | 0 |
3657336 | 133410 | None | 101 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates for Columns and piers Complete with all lead and lifts as directed by engineer-in-charge. | Cum | 13143.31 | 13143.31 | 15.65 | False | None | None | False | None | False | 205692.8015 | 0 |
3657337 | 133410 | None | 102 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification complete with lead and all lifts as directed by engineer-in-charge. | t | 97894.63 | 97894.63 | 2.79 | False | None | None | False | None | False | 273126.0177 | 0 |
3657338 | 133410 | None | 103 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. complete with lead and all lifts as directed by engineer-in-charge. | Cum | 329.57 | 329.57 | 52.84 | False | None | None | False | None | False | 17414.4788 | 0 |
3657339 | 133410 | None | 104 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 9884.74 | 9884.74 | 18.86 | False | None | None | False | None | False | 186426.1964 | 0 |
3657340 | 133410 | None | 105 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing Complete with all lead and lifts as directed by engineer-in-charge. | Sqm | 298.6 | 298.6 | 133.92 | False | None | None | False | None | False | 39988.512 | 0 |
3657341 | 133410 | None | 106 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing Complete with all lead and lifts as directed by engineer-in-charge. | Sqm | 438.61 | 438.61 | 165.47 | False | None | None | False | None | False | 72576.7967 | 0 |
3657342 | 133410 | None | 107 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm Complete with all lead and lifts as directed by engineer-in-charge. | Sqm | 1418.66 | 1418.66 | 51.58 | False | None | None | False | None | False | 73174.4828 | 0 |
3657343 | 133410 | None | 108 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour Complete with all lead and lifts as directed by engineer-in-charge. | Sqm | 195.76 | 195.76 | 165.47 | False | None | None | False | None | False | 32392.4072 | 0 |
3657344 | 133410 | None | 109 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage chargesof machinery Complete with all lead and lifts as directed by engineer-in-charge. | Sqm | 10253.96 | 10253.96 | 3.78 | False | None | None | False | None | False | 38759.9688 | 0 |
3657345 | 133410 | None | 110 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc.Complete with all lead and lifts as directed by engineer-in-charge. | Kg | 226.74 | 226.74 | 302.4 | False | None | None | False | None | False | 68566.176 | 0 |