3883367 | 149150 | None | cmy01 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. (Item No. 1.14.1 Page No. 8 Vol.1 PWD SR) | Cum | 105.06 | 105.06 | 92.0 | False | None | None | False | None | False | 9665.52 | 0 |
3883368 | 149150 | None | cmy02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates (The cost of steel reinforcement & formwork shall be paid separately. Specification No. KBS 2.1, (Item No. 2.1.2 Page No. 15 Vol.1 PWD SR) | Cum | 5833.92 | 5833.92 | 90.01 | False | None | None | False | None | False | 525111.1392 | 0 |
3883369 | 149150 | None | cmy03 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) | Cum | 7208.35 | 7208.35 | 24.16 | False | None | None | False | None | False | 174153.736 | 0 |
3883370 | 149150 | None | cmy04 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) [+] 8% (centering Charges) | Cum | 11346.48 | 11346.48 | 9.21 | False | None | None | False | None | False | 104501.0808 | 0 |
3883371 | 149150 | None | cmy05 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M30 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. Specification No. KBS 2.3., 2.3 (Item No. 2.3.2 Page No. 16 Vol.1 PWD SR & Appendix I page No.115) [+] 70% (centering Charges) | Cum | 7208.35 | 7208.35 | 106.21 | False | None | None | False | None | False | 765598.8535 | 0 |
3883372 | 149150 | None | cmy06 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately). M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (Item No. 2.2.3 Page No. 15 Vol.1 PWD SR & Appendix I page No.115) | Cum | 9789.12 | 9789.12 | 10.71 | False | None | None | False | None | False | 104841.4752 | 0 |
3883373 | 149150 | None | cmy07 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (Item No. 2.11 Page No. 18 Vol.1 PWD SR) | Tonne | 92140.71 | 92140.71 | 8.756 | False | None | None | False | None | False | 806784.05676 | 0 |
3883374 | 149150 | None | cmy08 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) . (Item No. 5.4 Page No. 9 Vol.2 PWD SR) | Cum | 6580.67 | 6580.67 | 41.79 | False | None | None | False | None | False | 275006.1993 | 0 |
3883375 | 149150 | None | cmy09 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work (Item No. 1.8 Page No. 7 Vol.1 PWD SR) | Cum | 488.22 | 488.22 | 565.36 | False | None | None | False | None | False | 276020.0592 | 0 |
3883376 | 149150 | None | cmy10 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. (Item No. 6.33 Page No. 17 Vol.2 PWD SR) | Cum | 1267.93 | 1267.93 | 275.14 | False | None | None | False | None | False | 348858.2602 | 0 |
3883377 | 149150 | None | cmy11 | Providing 20mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonary including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.(Item No. 8.3.1, Page No. 41, Vol.2) | Sqm | 364.62 | 364.62 | 600.14 | False | None | None | False | None | False | 218823.0468 | 0 |
3883378 | 149150 | None | cmy12 | Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge. (Item No. 11.2, Page No. 77, Vol.2) | Kgs | 116.39 | 116.39 | 26953.0 | False | None | None | False | None | False | 3137059.67 | 0 |
3883379 | 149150 | None | cmy13 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineerin-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Item No. 7.38, Page No. 26, Vol.2) | Sqm | 585.04 | 585.04 | 1625.46 | False | None | None | False | None | False | 950959.1184 | 0 |
3883380 | 149150 | None | cmy14 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge..(Item No. 8.28, Page No. 42, Vol.2) | Sqm | 91.67 | 91.67 | 600.14 | False | None | None | False | None | False | 55014.8338 | 0 |
3883381 | 149150 | None | cmy15 | Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (Item No. 11.6.1, Page No. 76, Vol.2) | Sqm | 2711.99 | 2711.99 | 27.0 | False | None | None | False | None | False | 73223.73 | 0 |
3883382 | 149150 | None | cmy16 | KSRB 11-11.8.4:Extra for providing 2 HP Mild Steel Auto Reverse Shutter Gearbox for operating rolling shutters including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Item No. 11.8.4, Page No. 77, Vol.2) | Nos | 25426.58 | 25426.58 | 2.0 | False | None | None | False | None | False | 50853.16 | 0 |
3883383 | 149150 | None | cmy17 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :For Fixed Portion: Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials, labour, usage charges of machinery complete as per specifications..(Item No. 11.35.1.1, Page No. 87, Vol.2) | Kgs | 465.56 | 465.56 | 480.0 | False | None | None | False | None | False | 223468.8 | 0 |
3883384 | 149150 | None | cmy18 | Supply, erection, testing and commissioning of LT Control Panel panel cubicle type made out of 14/16 Swg MS CRCA sheet which is derusted,degreased, phosphated and passivated with angle iron skeleton or sheet folded construction. The panel to be dust and vermin proof type and with powder coated paint after suitable seven tank pretreatment. The panel will have individual compartments for incoming and outgoing feeders made out of cold rolled sheet and doors fitted with Neoprene gaskets and fasteners.The switchboards are to be tested as per IS 8623-1977 specifications.Busbars are to be of high conductivity Aluminium Alloy E91E IS 5082 specification. The panel shall have both bottom & top cable entry provisions and panel shall be mounted on Pedestal of 300 mm height.Main PanelIncomer : MCCB TPN 100A with CBCT ELR & Ph indicators, meter section with all parameters as required 100A 4 Wire 25kA 415V Aluminium busbars compartment.Outgoings: 63A MCCB feeder- 01No.Outgoings: 16A MPCB feeder - 01NosOutgoings: 16A MPCB feeder - 02NosOutgoings: 63/40A MCB feeder- 08Nos | Nos | 85000.0 | 85000.0 | 1.0 | False | None | None | False | None | False | 85000.0 | 0 |
3883385 | 149150 | None | cmy19 | Sub panel-1 Incomer : MCB TPN 63A with CBCT ELR & Ph indicators, section with all parameters as required 63A 4 Wire 16kA 415V Aluminium busbars compartment.Outgoings: 40/63A 4P MCB feeder- 10No.Outgoings: 32A Industrial socket-02Nos.Outgoings: 16A Industrial socket-02Nos. | Nos | 35000.0 | 35000.0 | 1.0 | False | None | None | False | None | False | 35000.0 | 0 |
3883386 | 149150 | None | cmy20 | LT Cables Supply & laying 1.1kV LT UG cable XLPE / heat resistant PVC insulated, PVC extruded inner sheath armoured as per IS:1554 part-1 or IS:7098 part-1, Armouring thickness +5% and resistivity 14 Ohms /Kms Max as per IS: 3975. Glands & Lugs not included.3.5Cx50 Sqmm Al Ar cable (16 GI Strips- 4x0.8mm) | Km | 184342.19 | 184342.19 | 0.1 | False | None | None | False | None | False | 18434.219 | 0 |
3883387 | 149150 | None | cmy21 | 4Cx25 Sqmm Al Ar cable (13 GI Strips- 4x0.8mm) | Km | 185239.32 | 185239.32 | 0.1 | False | None | None | False | None | False | 18523.932 | 0 |
3883388 | 149150 | None | cmy22 | 4Cx16 Sqmm Al Ar cable (11 GI Strips- 4x0.8mm) | Km | 146097.26 | 146097.26 | 0.05 | False | None | None | False | None | False | 7304.863 | 0 |
3883389 | 149150 | None | cmy23 | 4Cx10 Sqmm Cu Ar cable (10 GI Strips- 4x0.8mm) | Km | 121544.12 | 121544.12 | 0.05 | False | None | None | False | None | False | 6077.206 | 0 |
3883390 | 149150 | None | cmy24 | Supply & installation of LT Cables End termination - Heavyduty cable Glands suitable for UG cable of 1.1kV Class.3.5Cx50 Sqmm Al Ar cable | Set | 385.0 | 385.0 | 2.0 | False | None | None | False | None | False | 770.0 | 0 |
3883391 | 149150 | None | cmy25 | 4Cx25 Sqmm Al Ar cable | Set | 250.0 | 250.0 | 2.0 | False | None | None | False | None | False | 500.0 | 0 |
3883392 | 149150 | None | cmy26 | 4Cx16 Sqmm Al Ar cable | Set | 225.0 | 225.0 | 2.0 | False | None | None | False | None | False | 450.0 | 0 |
3883393 | 149150 | None | cmy27 | 4Cx10 Sqmm Cu Ar cable | Set | 200.0 | 200.0 | 2.0 | False | None | None | False | None | False | 400.0 | 0 |
3883394 | 149150 | None | cmy28 | 4Cx6.0 Sqmm Cu Ar cable | Set | 185.0 | 185.0 | 2.0 | False | None | None | False | None | False | 370.0 | 0 |
3883395 | 149150 | None | cmy29 | 3Cx6.0 Sqmm Cu Un Ar cable | Set | 145.0 | 145.0 | 2.0 | False | None | None | False | None | False | 290.0 | 0 |
3883396 | 149150 | None | cmy30 | 3Cx4.0 Sqmm Cu Un Ar cable | Set | 138.0 | 138.0 | 2.0 | False | None | None | False | None | False | 276.0 | 0 |
3883397 | 149150 | None | cmy31 | Supply & installation of Tinned Copper lugs crimping & wiring to terminal point.50 Sqmm Preinsulated lug.CPTAU | Nos | 314.15 | 314.15 | 3.0 | False | None | None | False | None | False | 942.45 | 0 |
3883398 | 149150 | None | cmy32 | 25 Sqmm Preinsulated lug.CPTAU | No | 295.61 | 295.61 | 3.0 | False | None | None | False | None | False | 886.83 | 0 |
3883399 | 149150 | None | cmy33 | 16 Sqmm Preinsulated lug.CPTAU | No | 146.26 | 146.26 | 2.0 | False | None | None | False | None | False | 292.52 | 0 |
3883400 | 149150 | None | cmy34 | 10 Sqmm Preinsulated lug.CPTAU | No | 120.0 | 120.0 | 2.0 | False | None | None | False | None | False | 240.0 | 0 |
3883401 | 149150 | None | cmy35 | 6.0 Sqmm Preinsulated lug.CPTAU | No | 110.0 | 110.0 | 2.0 | False | None | None | False | None | False | 220.0 | 0 |
3883402 | 149150 | None | cmy36 | 6.0 Sqmm Preinsulated lug.CPTAU | No | 90.0 | 90.0 | 2.0 | False | None | None | False | None | False | 180.0 | 0 |
3883403 | 149150 | None | cmy37 | 4.0 Sqmm Preinsulated lug.CPTAU | No | 85.0 | 85.0 | 2.0 | False | None | None | False | None | False | 170.0 | 0 |
3883404 | 149150 | None | cmy38 | Supplying & Fixing heavey guage PVC conduit type 2mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc, and shall be concealed in wall/RCC slab or exposed on fixing invrted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick wall & cement plastering the damaged portion using heavy gauage saddles at interval of 700mm using NF screws.19/20mm dia PVC 2mm thick conduit | Mtr | 71.07 | 71.07 | 30.0 | False | None | None | False | None | False | 2132.1 | 0 |
3883405 | 149150 | None | cmy39 | 25mm dia PVC 2mm thick conduit | Mtr | 83.43 | 83.43 | 30.0 | False | None | None | False | None | False | 2502.9 | 0 |
3883406 | 149150 | None | cmy40 | 32mm dia PVC 2mm thick conduit | Mtr | 109.18 | 109.18 | 30.0 | False | None | None | False | None | False | 3275.4 | 0 |
3883407 | 149150 | None | cmy41 | 40mm dia PVC 2mm thick conduit | Mtr | 153.47 | 153.47 | 30.0 | False | None | None | False | None | False | 4604.1 | 0 |
3883408 | 149150 | None | cmy42 | Point wiring using Copper wire with switch Supply & wiring from switch board upto first light point & looped continously for the extent light points. Wire size 2x1.5 Sqmm Ph-N & 1x1.0Sqmm for E for point wiring laid in existing conduit.1 Light point upto 3Mtr from switch board | Nos | 293.55 | 293.55 | 2.0 | False | None | None | False | None | False | 587.1 | 0 |
3883409 | 149150 | None | cmy43 | 1 Light point above 3M upto 6Mtr from switch board | Nos | 405.82 | 405.82 | 2.0 | False | None | None | False | None | False | 811.64 | 0 |
3883410 | 149150 | None | cmy44 | 1 Light point above 6M upto 10Mtr from switch board | Nos | 587.1 | 587.1 | 3.0 | False | None | None | False | None | False | 1761.3 | 0 |
3883411 | 149150 | None | cmy45 | Two outlet in a row above 3Mtr upto 6Mtr from switch board | Nos | 729.24 | 729.24 | 3.0 | False | None | None | False | None | False | 2187.72 | 0 |
3883412 | 149150 | None | cmy46 | Three outlet in a row above 6Mtr upto 10Mtr from switch board | Nos | 1066.05 | 1066.05 | 3.0 | False | None | None | False | None | False | 3198.15 | 0 |
3883413 | 149150 | None | cmy47 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.0 Sqmm Cu FRLS wire | Mtr | 19.57 | 19.57 | 300.0 | False | None | None | False | None | False | 5871.0 | 0 |
3883414 | 149150 | None | cmy48 | 1.5 Sqmm Cu FRLS wire | Mtr | 26.78 | 26.78 | 300.0 | False | None | None | False | None | False | 8034.0 | 0 |
3883415 | 149150 | None | cmy49 | 2.5 Sqmm Cu FRLS wire | Mtr | 43.26 | 43.26 | 300.0 | False | None | None | False | None | False | 12978.0 | 0 |
3883416 | 149150 | None | cmy50 | 4.0 Sqmm Cu FRLS wire | Mtr | 64.89 | 64.89 | 50.0 | False | None | None | False | None | False | 3244.5 | 0 |
3883417 | 149150 | None | cmy51 | 6.0 Sqmm Cu FRLS wire | Mtr | 94.76 | 94.76 | 50.0 | False | None | None | False | None | False | 4738.0 | 0 |
3883418 | 149150 | None | cmy52 | Switches & sockets outlets in Existing modular box 6A one way switch | Nos | 105.06 | 105.06 | 4.0 | False | None | None | False | None | False | 420.24 | 0 |
3883419 | 149150 | None | cmy53 | 6A three way switch | Nos | 176.13 | 176.13 | 2.0 | False | None | None | False | None | False | 352.26 | 0 |
3883420 | 149150 | None | cmy54 | Stepped fan regulator | Nos | 367.71 | 367.71 | 2.0 | False | None | None | False | None | False | 735.42 | 0 |
3883421 | 149150 | None | cmy55 | 6/16A Universal socket | Nos | 243.08 | 243.08 | 2.0 | False | None | None | False | None | False | 486.16 | 0 |
3883422 | 149150 | None | cmy56 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr at Lumen Maintenance of 70percentage, CCT greaterthan 5500K, IP 66 optical and electrical compartment and impact resistance of complete luminaire greaterthan IK08. Power Factor greaterthan0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 and LM 80 Adherence with RoHS. UL approved MCPCB. Top - house facility accredited by NABL / CPRI and any Government certified agency and Design and Developmentfacility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer and Cree/Nichia/ Lumileds/Osram make LED Source | Nos | 9770.58 | 9770.58 | 14.0 | False | None | None | False | None | False | 136788.12 | 0 |
3883423 | 149150 | None | cmy57 | GI/Copper strips for grounding connections, using necessary fixing materials as required. 25 x 6 mm GI strip | Mtr | 131.84 | 131.84 | 80.0 | False | None | None | False | None | False | 10547.2 | 0 |
3883424 | 149150 | None | cmy58 | 8 SWG GI Wire
(4.064 mm Dia), Std Wt: 131 Kg/KM , | Mtr | 77291.2 | 77291.2 | 0.032 | False | None | None | False | None | False | 2473.3184 | 0 |
3883425 | 149150 | None | cmy59 | Supply & installation of Cable Trays fixed with MS angles, hitech & anchor fastner supports at interval 0.9M interval shall be included complete run below ceiling/wall.Supplying & Laying cable trays including welding, fixing of supports Cable tray of 300 mm width (suitable for cable duct of D type) | Mtr | 776.62 | 776.62 | 50.0 | False | None | None | False | None | False | 38831.0 | 0 |