1725332817000 | 0 | None | None | Buildings | Construction of Physically challenged Toilet at lower primary School, ward no. 1 in limits of TMC Bidadi | 402656.77 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3905289 | 150558 | None | 1.1 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. (I. No 1.5.1, P. No-6, Vol-1, of Common SR 2023-24) | Cum | 307.97 | 307.97 | 12.3 | False | None | None | False | None | False | 3788.031 | 0 | 3905290 | 150558 | None | 1.2 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates(I. No 2.1.2, P. No-15, Vol-1 of Common SR 2023-24) | Cum | 5833.92 | 5833.92 | 1.84 | False | None | None | False | None | False | 10734.4128 | 0 | 3905291 | 150558 | None | 1.3 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (I. No 5.4, P. No-9, Vol-2 of Common SR 2023-24) | Cum | 6580.67 | 6580.67 | 8.96 | False | None | None | False | None | False | 58962.8032 | 0 | 3905292 | 150558 | None | 1.5 | Providing Flush/ Ruled pointing: Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) after raking joints to depth nicely lin ing, including cost of materials, labour, curing as per specifications and as per directions of Engineer-in-charge (I. No 8.19.1, P. No-44, Vol-2 of Common SR 2023-24) | Sqm | 262.65 | 262.65 | 3.83 | False | None | None | False | None | False | 1005.9495 | 0 | 3905293 | 150558 | None | 1.6 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m (I. No 1.9, P. No-7, Vol-1 of Common SR 2023-24) | Cum | 273.98 | 273.98 | 3.23 | False | None | None | False | None | False | 884.9554 | 0 | 3905294 | 150558 | None | 1.7 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite / trap / basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (I. No 2.4.2, P. No-16, Vol-1 of Common SR 2023-24) | Cum | 6512.69 | 6512.69 | 2.34 | False | None | None | False | None | False | 15239.6946 | 0 | 3905295 | 150558 | None | 1.8 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (I. No 2.4.2, P. No-16, Vol-1 of Common SR 2023-24) | Cum | 9769.04 | 9769.04 | 0.51 | False | None | None | False | None | False | 4982.2104 | 0 | 3905296 | 150558 | None | 1.9 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (I. No 2.5.1, P. No-16, Vol-1 of Common SR 2023-24) | Cum | 10926.24 | 10926.24 | 0.77 | False | None | None | False | None | False | 8413.2048 | 0 | 3905297 | 150558 | None | 1.10 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Slab (I. No 2.5.1, P. No-16, Vol-1 of Common SR 2023-24) | Cum | 10243.35 | 10243.35 | 0.8 | False | None | None | False | None | False | 8194.68 | 0 | 3905298 | 150558 | None | 1.11 | Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates Chajja (I. No 2.5.1, P. No-16, Vol-1 of Common SR 2023-24) | Cum | 9901.91 | 9901.91 | 0.09 | False | None | None | False | None | False | 891.1719 | 0 | 3905299 | 150558 | None | 1.12 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (I. No 2.11 (a) P. No-18, Vol-1 of Common SR 2023-24) | Tonne | 92140.71 | 92140.71 | 0.23 | False | None | None | False | None | False | 21192.3633 | 0 | 3905300 | 150558 | None | 1.13 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Ground Floor (I. No 6.32, P. No-17, Vol-1 of Common SR 2023-24) | Sqm | 1349.3 | 1349.3 | 29.75 | False | None | None | False | None | False | 40141.675 | 0 | 3905301 | 150558 | None | 1.14 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Terrace (I. No 6.32, P. No-17, Vol-1 of Common SR 2023-24) | Sqm | 1362.79 | 1362.79 | 2.21 | False | None | None | False | None | False | 3011.7659 | 0 | 3905302 | 150558 | None | 1.15 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (External Wall Plastering) (I. No 8.8, P. No-42, Vol-2 of Common SR 2023-24) | Sqm | 382.13 | 382.13 | 38.53 | False | None | None | False | None | False | 14723.4689 | 0 | 3905303 | 150558 | None | 1.16 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Terrace (I. No 8.8, P. No-42, Vol-2 of Common SR 2023-24) | Sqm | 385.95 | 385.95 | 10.23 | False | None | None | False | None | False | 3948.2685 | 0 | 3905304 | 150558 | None | 1.17 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Internal Wall Plastering) (I. No 8.1.2, P. No-41, Vol-2 of Common SR 2023-24) | Sqm | 248.23 | 248.23 | 26.0 | False | None | None | False | None | False | 6453.98 | 0 | 3905305 | 150558 | None | 1.18 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Internal Ceiling Plastering) (I. No 8.10, P. No-43, Vol-2 of Common SR 2023-24) | Sqm | 217.33 | 217.33 | 4.53 | False | None | None | False | None | False | 984.5049 | 0 | 3905306 | 150558 | None | 1.19 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. For Daddoing (I. No 8.2.1, P. No-41, Vol-2 of Common SR 2023-24) | Sqm | 303.85 | 303.85 | 18.53 | False | None | None | False | None | False | 5630.3405 | 0 | 3905307 | 150558 | None | 1.20 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. External wall painting (I. No 8.28, P. No-45, Vol-2 of Common SR 2023-24) | Sqm | 91.67 | 91.67 | 38.53 | False | None | None | False | None | False | 3532.0451 | 0 | 3905308 | 150558 | None | 1.21 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. External wall painting Terrace (I. No 8.28, P. No-45, Vol-2 of Common SR 2023-24) | Sqm | 92.59 | 92.59 | 10.23 | False | None | None | False | None | False | 947.1957 | 0 | 3905309 | 150558 | None | 1.22 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. (Internal + Ceiling Painting) (I. No 8.51, P. No-50, Vol-2 of Common SR 2023-24) | Sqm | 103.0 | 103.0 | 30.54 | False | None | None | False | None | False | 3145.62 | 0 | 3905310 | 150558 | None | 1.23 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (I. No 8.39, P. No-48, Vol-2 of Common SR 2023-24) | Sqm | 130.81 | 130.81 | 30.54 | False | None | None | False | None | False | 3994.9374 | 0 | 3905311 | 150558 | None | 1.24 | Providing and laying Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Dark shade pigment using ordinary cement (I. No 9.6.3, P. No-59, Vol-2 of Common SR 2023-24) | Sqm | 1155.66 | 1155.66 | 10.8 | False | None | None | False | None | False | 12481.128 | 0 | 3905312 | 150558 | None | 1.25 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thick ness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. For Toilet Flooring (I. No 9.11, P. No-60, Vol-2 of Common SR 2023-24) | Sqm | 915.67 | 915.67 | 4.13 | False | None | None | False | None | False | 3781.7171 | 0 | 3905313 | 150558 | None | 1.26 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete. Toilet dadooing (I. No 10.14, P. No-71, Vol-2 of Common SR 2023-24) | Sqm | 1139.18 | 1139.18 | 18.53 | False | None | None | False | None | False | 21109.0054 | 0 | 3905314 | 150558 | None | 1.27 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding (I. No 11.34A, P. No-86, Vol-2 of Common SR 2023-24) | Kgs | 173.04 | 173.04 | 18.9 | False | None | None | False | None | False | 3270.456 | 0 | 3905315 | 150558 | None | 1.28 | Providing and fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL 9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (I. No 12.85, P. No-109, Vol-2 of Common SR 2023-24) | Sqm | 5890.57 | 5890.57 | 0.9 | False | None | None | False | None | False | 5301.513 | 0 | 3905316 | 150558 | None | 1.29 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately). Size 62 x 150mm. For Toilets (I. No 12.93.3, P. No-111, Vol-2 of Common SR 2023-24) | m | 831.21 | 831.21 | 5.7 | False | None | None | False | None | False | 4737.897 | 0 | 3905317 | 150558 | None | 1.30 | Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately). For Toilets (I. No 12.95, P. No-112, Vol-2 of Common SR 2023-24) | Sqm | 4543.33 | 4543.33 | 1.58 | False | None | None | False | None | False | 7178.4614 | 0 | 3905318 | 150558 | None | 1.31 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge (I. No 11.26.1, P. No-84, Vol-2 of Common SR 2023-24) | Kg | 142.14 | 142.14 | 224.44 | False | None | None | False | None | False | 31901.9016 | 0 | 3905319 | 150558 | None | 1.32 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (I. No 11.28, P. No-85, Vol-2 of Common SR 2023-24) | Kg | 581.95 | 581.95 | 19.44 | False | None | None | False | None | False | 11313.108 | 0 | 3905320 | 150558 | None | 1.33 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU wa terproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the wa terproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification. (I. No 15.1, P. No-149, Vol-2 of Common SR 2023-24) | Sqm | 841.51 | 841.51 | 4.13 | False | None | None | False | None | False | 3475.4363 | 0 | 3905321 | 150558 | None | 1.34 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU wa terproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the wa terproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification Terrace (I. No 15.1, P. No-149, Vol-2 of Common SR 2023-24) | Sqm | 849.93 | 849.93 | 5.95 | False | None | None | False | None | False | 5057.0835 | 0 | 3905322 | 150558 | None | 1.35 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid (I. No 14.2.1, P. No-131, Vol-2 of Common SR 2023-24) | Each | 4983.14 | 4983.14 | 1.0 | False | None | None | False | None | False | 4983.14 | 0 | 3905323 | 150558 | None | 1.36 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap. | Each | 2415.35 | 2415.35 | 1.0 | False | None | None | False | None | False | 2415.35 | 0 | 3905324 | 150558 | None | 1.37 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. (I. No 16.9, P. No-191, Vol-5 of KUWS&DB SR 2023-24) | Each | 5617.62 | 5617.62 | 1.0 | False | None | None | False | None | False | 5617.62 | 0 | 3905325 | 150558 | None | 1.38 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 75mm dia., 6 kg/sqcm & class 3 (I. No 10.1.5, P. No-113, Vol-5 of KUWS&DB SR 2023-24) | m | 226.6 | 226.6 | 12.0 | False | None | None | False | None | False | 2719.2 | 0 | 3905326 | 150558 | None | 1.39 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 110mm dia , 6 kg/sqcm & class 3 (I. No 10.1.7, P. No-113, Vol-5 of KUWS&DB SR 2023-24) | m | 423.33 | 423.33 | 10.0 | False | None | None | False | None | False | 4233.3 | 0 | 3905327 | 150558 | None | 1.40 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal dia pipes (I. No 13.32.1, P. No-122, Vol-2 of COMMON SR 2023-24) | m | 318.27 | 318.27 | 12.0 | False | None | None | False | None | False | 3819.24 | 0 | 3905328 | 150558 | None | 1.41 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 20 mm nominal dia pipes (I. No 13.32.2, P. No-122, Vol-2 of COMMON SR 2023-24) | m | 390.37 | 390.37 | 12.0 | False | None | None | False | None | False | 4684.44 | 0 | 3905329 | 150558 | None | 1.42 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (25mm Nominal Dia Pipe) (I. No 13.33.3, P. No-122, Vol-2 of COMMON SR 2023-24) | m | 304.88 | 304.88 | 10.0 | False | None | None | False | None | False | 3048.8 | 0 | 3905330 | 150558 | None | 1.43 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work (32mm Nominal Dia Pipe) (I. No 13.33.4, P. No-122, Vol-2 of COMMON SR 2023-24) | m | 383.16 | 383.16 | 10.0 | False | None | None | False | None | False | 3831.6 | 0 | 3905331 | 150558 | None | 1.44 | Providing and fixing brass bib cock of approved quality.15 mm nominal bore (I. No 13.2.1 P. No-117, Vol-2 of COMMON SR 2023-24) | No | 294.58 | 294.58 | 3.0 | False | None | None | False | None | False | 883.74 | 0 | 3905332 | 150558 | None | 1.45 | Providing and fixing brass stop cock of approved quality.15 mm nominal bore (I. No 13.3.1 P. No-115, Vol-2 of COMMON SR 2023-24) | No | 307.97 | 307.97 | 2.0 | False | None | None | False | None | False | 615.94 | 0 | 3905333 | 150558 | None | 1.46 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal bore (I. No 13.5.3 P. No-115, Vol-2 of COMMON SR 2023-24) | No | 341.96 | 341.96 | 2.0 | False | None | None | False | None | False | 683.92 | 0 | 3905334 | 150558 | None | 1.47 | Providing and fixing PVC (S.W.R) Gully Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete(I. No 13.58, P. No-127, Vol-2 of COMMON SR 2023-24) | No | 356.38 | 356.38 | 2.0 | False | None | None | False | None | False | 712.76 | 0 | 3905335 | 150558 | None | 1.48 | Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete (I. No 13.59, P. No-127, Vol-2 of COMMON SR 2023-24) | No | 226.6 | 226.6 | 2.0 | False | None | None | False | None | False | 453.2 | 0 | 3905336 | 150558 | None | 1.49 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (I. No 13.34, P. No-123, Vol-2 of COMMON SR 2023-24) | l | 9.27 | 9.27 | 500.0 | False | None | None | False | None | False | 4635.0 | 0 | 3905337 | 150558 | None | 1.50 | Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0sqmm (Earth wire) FRLS multistrand PVC insulated copper wire (confirming to IS-694:and latest amendments) without control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wiress hall be terminated with sufficient loose length in a wood / PVC round block. complete for each outlet. Short point upto 3Mtr from tapping point to out let via switch box. (I. No 2.2.1, P. No-5 of 105, PWD Ele SR 2023-24) | Point | 277.07 | 277.07 | 6.0 | False | None | None | False | None | False | 1662.42 | 0 | 3905338 | 150558 | None | 1.51 | Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0sqmm (Earth wire) FRLS multistrand PVC insulated copper wire (confirming to IS-694:and latest amendments) without control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wiress hall be terminated with sufficient loose length in a wood / PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch box. (I. No 2.2.2, P. No-5 of 105, PWD Ele SR 2023-24) | Point | 390.37 | 390.37 | 5.0 | False | None | None | False | None | False | 1951.85 | 0 | 3905339 | 150558 | None | 1.52 | Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0sqmm (Earth wire) FRLS multistrand PVC insulated copper wire (confirming to IS-694:and latest amendments) without control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wiress hall be terminated with sufficient loose length in a wood / PVC round block. complete for each outlet. Long point above 6Mtr upto10Mtr from tapping point to outlet via switch box. (I. No 2.2.3, P. No-5 of 105, PWD Ele SR 2023-24) | Point | 571.65 | 571.65 | 5.0 | False | None | None | False | None | False | 2858.25 | 0 | 3905340 | 150558 | None | 1.53 | Supplying and wiring adopting loop system in existing PVC Conduit / casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0sqmm (Earthwire) FRLS multistrand PVC insulated copper wire (confirming to IS-694:and latest amendments) without control switch shall be fixed on the existing plastic sheet / gang box, the other end of the wiress hall be terminated with sufficient loose length in a wood / PVC round block. complete for each outlet. Two outlet in arow,above 3Mtr upto 6Mtr from tapping point to outlet via switches (I. No 2.2.4, P. No-5 of 105, PWD Ele SR 2023-24) | Point | 697.31 | 697.31 | 4.0 | False | None | None | False | None | False | 2789.24 | 0 | 3905341 | 150558 | None | 1.54 | Supplying heavy gauge PVC conduit pipe......mm dia..........mm thick confirming to IS2509 with suitable size bends,metal / PVC Junction boxes,adhesive paste etc.,and running before concreting the slab.The conduit should be tied to there in for cement rods by using binding wires and un used ways of junction boxes and pipe ends should be covered using PVC end enclosures,run with18SWGGI fish wire wherever necessary. 25 mm dia 2 mm thick (I. No. 1.2.2, P. No-2 of 105, PWD Ele SR 2023-24) | m | 80.34 | 80.34 | 15.0 | False | None | None | False | None | False | 1205.1 | 0 | 3905342 | 150558 | None | 1.55 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete. 10" x 7" x 3" (254 x 178 x 76 mm) (I. No. 1.6.3, P. No-3 of 105, PWD Ele SR 2023-24) | Each | 115.36 | 115.36 | 2.0 | False | None | None | False | None | False | 230.72 | 0 | 3905343 | 150558 | None | 1.56 | Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3854. 6A 3/5 Way (I. No. 3.1.2, P. No-8 of 105, PWD Ele SR 2023-24) | Each | 151.41 | 151.41 | 1.0 | False | None | None | False | None | False | 151.41 | 0 | 3905344 | 150558 | None | 1.57 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010. 1.5 mm2 (I. No. 2.3.2, P. No-5 of 105, PWD Ele SR 2023-24) | m | 26.78 | 26.78 | 15.0 | False | None | None | False | None | False | 401.7 | 0 | 3905345 | 150558 | None | 1.58 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010. 2.5 mm2 (I. No. 2.3.3, P. No-5 of 105, PWD Ele SR 2023-24) | m | 43.26 | 43.26 | 15.0 | False | None | None | False | None | False | 648.9 | 0 | 3905346 | 150558 | None | 1.59 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:2010 .4 mm2 (I. No 2.3.4, P. No-5 of 105, PWD Ele SR 2023-24) | m | 60.77 | 60.77 | 15.0 | False | None | None | False | None | False | 911.55 | 0 | 3905347 | 150558 | None | 1.60 | Supplying 4mm thick plastic sheet with necessary nitches for fixing switches, regulators etc., and fixing on existing wooden or metal box using N.F. screws. (4mm Plastic sheet) (I. No. 3.8, P. No-9 of 105, PWD Ele SR 2023-24) | Sqm | 0.42 | 0.42 | 16.0 | False | None | None | False | None | False | 6.72 | 0 | 3905348 | 150558 | None | 1.61 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300 mm) (I. No. 6.2.1, P. No-30 of 105, PWD Ele SR 2023-24) | Each | 3058.07 | 3058.07 | 1.0 | False | None | None | False | None | False | 3058.07 | 0 | 3905349 | 150558 | None | 1.62 | Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girdersusing 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall/ ceiling / Rafter / Girders (I. No. 13.7.1, P. No-56 of 105, PWD Ele SR 2023-24) | Each | 125.66 | 125.66 | 2.0 | False | None | None | False | None | False | 251.32 | 0 | 3905350 | 150558 | None | 1.63 | Supplying heavy gauge PVC Conduit Pipe .... dia ....... mm thick with suitable size bends, metal junction boxes adhesive paste etc., by groove cutting in the wall and fixing by bracing U or J hooks and cement plastering upto the wall surface and run with 18 SWG GI fish wire run throughout the conduit wherever necessary. 25 mm dia 2 mm thick (I. No. 1.3.2, P. No-2 of 105, PWD Ele SR 2023-24) | m | 81.37 | 81.37 | 15.0 | False | None | None | False | None | False | 1220.55 | 0 | 3905351 | 150558 | None | 1.64 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. III - Double Door 6 Way TP & N (I. No. 5.19.12, P. No-18 of 105, PWD Ele SR 2023-24) | Each | 5088.2 | 5088.2 | 1.0 | False | None | None | False | None | False | 5088.2 | 0 | 3905352 | 150558 | None | 1.65 | Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 63 A 4 pole (I. No. 5.20.10, P. No-18 of 105, PWD Ele SR 2023-24) | Each | 5711.35 | 5711.35 | 1.0 | False | None | None | False | None | False | 5711.35 | 0 | 3905353 | 150558 | None | 1.66 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 A DP (I. No. 5.18.4, P. No-17 of 105, PWD Ele SR 2023-24) | Each | 761.17 | 761.17 | 1.0 | False | None | None | False | None | False | 761.17 | 0 |
|