1725878728000 | 0 | None | None | Other Works | Expenditure for completion of construction works under Purakrikam Griha Bhagya Yojana for the welfare of civil servants. | 1234584.45 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3944289 | 152694 | None | PWD SR- 2023-24-Vol.2-Page No.17- Item No. 3.7 | Compacting Original Ground Compacting original ground supporting embankment Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment,scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. | Cum | 117.6 | 117.6 | 193.8 | False | None | None | False | None | False | 22790.88 | 0 | 3944290 | 152694 | None | PWD SR- 2023-24-Vol.2-Page No.42- Item No.8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding,including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 415.52 | 415.52 | 77.94 | False | None | None | False | None | False | 32385.6288 | 0 | 3944291 | 152694 | None | PWD SR- 2023-24-Vol.2-Page No.59- Item No.9.7.1 | Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.
In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid
and alkali resistant tile | Sqm | 1395.52 | 1395.52 | 16.2 | False | None | None | False | None | False | 22607.424 | 0 | 3944292 | 152694 | None | PWD SR- 2023-24-Vol.2-Page No.71-Item No.10.14 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching
shade complete. | Sqm | 1238.72 | 1238.72 | 67.32 | False | None | None | False | None | False | 83390.6304 | 0 | 3944293 | 152694 | None | PWD SR- 2023-24-Vol.2-Page No.50- ItemNo.8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as
per directions of Engineer in charge. | Sqm | 112.0 | 112.0 | 652.88 | False | None | None | False | None | False | 73122.56 | 0 | 3944294 | 152694 | None | PWD SR- 2023-24-Vol.2-Page No.50- ItemNo.8.51 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as
per directions of Engineer in charge. | Sqm | 113.0 | 113.0 | 652.88 | False | None | None | False | None | False | 73775.44 | 0 | 3944295 | 152694 | None | PWD SR- 2023-24-Vol.2-Page No.46- ItemNo.8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of
Engineer-in-charge | Sqm | 194.88 | 194.88 | 123.15 | False | None | None | False | None | False | 23999.472 | 0 | 3944296 | 152694 | None | PWD SR- 2023-24-Vol.2-Page No.46- ItemNo.8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of
Engineer-in-charge | Sqm | 196.62 | 196.62 | 102.63 | False | None | None | False | None | False | 20179.1106 | 0 | 3944297 | 152694 | None | PWD SR- 2023-24-Vol.2-Page No.46- ItemNo.8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of
Engineer-in-charge | Sqm | 198.36 | 198.36 | 197.43 | False | None | None | False | None | False | 39162.2148 | 0 | 3944298 | 152694 | None | PWD SR- 2023-24-Vol.2-Page No.45- ItemNo.8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 153.44 | 153.44 | 652.88 | False | None | None | False | None | False | 100177.9072 | 0 | 3944299 | 152694 | None | PWD SR- 2023-24-Vol.2-Page No.45- ItemNo.8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 154.81 | 154.81 | 652.88 | False | None | None | False | None | False | 101072.3528 | 0 | 3944300 | 152694 | None | PWD SR- 2023-24-Vol.2-Page No.45- ItemNo.8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 156.18 | 156.18 | 652.88 | False | None | None | False | None | False | 101966.7984 | 0 | 3944301 | 152694 | None | PWD SR- 2023-24-Vol.2-Page62- Item No.9.21.2 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made
separately).Size of Tile 600x600 mm | Sqm | 1386.56 | 1386.56 | 189.55 | False | None | None | False | None | False | 262822.448 | 0 | 3944302 | 152694 | None | PWD SR- 2023-24-Vol.2-Page61- Item No.9.19 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser, treads of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints as per direction of Engineer in charge. | Sqm | 1313.76 | 1313.76 | 31.24 | False | None | None | False | None | False | 41041.8624 | 0 | 3944303 | 152694 | None | PWD SR- 2023-24-Vol.2-Page64-Item No.9.36 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete
as per specifications. | Sqm | 1866.48 | 1866.48 | 13.4 | False | None | None | False | None | False | 25010.832 | 0 | 3944304 | 152694 | None | PWD SR- 2023-24-Vol.2-Page No.104-Item No.12.55.2 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S.tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S.frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hingese.-do- with one side prelam | Sqm | 2284.84 | 2284.84 | 7.56 | False | None | None | False | None | False | 17273.3904 | 0 | 3944305 | 152694 | None | PWD SR- 2023-24-Vol.1-Page No.8-Item No.1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.
In all kinds of soils upto 300 mm depth | Cum | 106.4 | 106.4 | 2.56 | False | None | None | False | None | False | 272.384 | 0 | 3944306 | 152694 | None | PWD SR- 2023-24-Vol.1-Page No.15-Item No.2.1.4 | Providing and laying in position Cement Concrete for levelling course for all works in foundation.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.
Mix 1:3:6 Using 20 mm nominal size graded
crushed coarse aggregates | Cum | 6963.04 | 6963.04 | 1.28 | False | None | None | False | None | False | 8912.6912 | 0 | 3944307 | 152694 | None | PWD SR- 2023-24-Vol.3-Page No.26-Item No.4.17 | Wet Mix Macadam (Plant Mix Method) Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to
achieve the desired density. | Cum | 2866.08 | 2866.08 | 11.52 | False | None | None | False | None | False | 33017.2416 | 0 | 3944308 | 152694 | None | PWD SR- 2023-24-Vol.2-Page No.246-Item No.9.3.2 | Providing and laying 80mm thick factory made precast M-30 grade Cement Concrete Paver Block as per IRC SP 63:2018 & IS 15658 for Commercial Traffic Axle load repetitions upto 10MSA & for Residential Streets of approved shape and colour, laid in required pattern and including over 40mm thick compacted bed of coarse sand, filling the joints with fine sand etc.all complete as per the direction of Engineer-in-charge.(WMM/WBM Base to be paid separately as per relevant technical
specification) | Sqm | 1300.32 | 1300.32 | 115.2 | False | None | None | False | None | False | 149796.864 | 0 | 3944309 | 152694 | None | PWD SR- 2023-24-Vol.3-Page No.123-Item No.13.14 | Painting on concrete surface
Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt, dust, oil, grease, efflorescence and applying paint @ of 1 litre for 2 m2. | Sqm | 94.08 | 94.08 | 19.2 | False | None | None | False | None | False | 1806.336 | 0 |
| 1725878728000 | 0 | None | None | Other Works | Ward No. 17 - Rabindranagar - road development work within the ward area where Scheduled Caste people live and Ward No. 3 Anganwadi Construction Work in Ambedkar Nagar Area | 2963068.75 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3944310 | 152695 | None | PWD SR 2023- 24 Volume-1 Page No.8 Item No. 1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications,including setting out,shoring,strutting,barricading,caution lights,removal of stumps and other deleterious matter including dressing of excavated surfaces,disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour,tools,usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth
| Cum | 106.4 | 106.4 | 201.6 | False | None | None | False | None | False | 21450.24 | 0 | 3944311 | 152695 | None | PWD CSR 2023-24 Vol:3 P.NO.17 I.No:3.7 | Compacting original ground supporting embankment Loosening,leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment,scarified to a depth of 150 mm,mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. | Cum | 117.6 | 117.6 | 134.4 | False | None | None | False | None | False | 15805.44 | 0 | 3944312 | 152695 | None | PWD SR 2023-24 Vol:3 P.NO.26 I.No:4.17 | Wet Mix Macadam (Plant Mix Method)
Providing,laying,spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site,laying in uniform layers with paver/grader in sub-base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. | Cum | 2866.08 | 2866.08 | 67.2 | False | None | None | False | None | False | 192600.576 | 0 | 3944313 | 152695 | None | PWD SR 2023-24 Vol:3 P.NO.50 I.No:6.5 | Construction of M30 Grade un-reinforced,dowel jointed,plain cement concrete pavement over a prepared sub base with OPC @ 270 kg/m3 and GGBS@ 90 kg/m3 ,coarse and fine aggregate conforming to IS 383:2016,maximum size of coarse aggregate not exceeding 25 mm,mixed in a batching and mixing plant as per approved mix design transported to site,laid with a paver finisher,spread,compacted and finished in a continuous operation including provision of contraction,expansion,construction and longitudinal joints,joint filler,separation membrane,sealant primer,joint sealant,debonding strip,dowel bar,tie rod,admixtures,curing compound,steel channels,finishing to lines and grades as per drawing. | Cum | 9218.66 | 9218.66 | 94.5 | False | None | None | False | None | False | 871163.37 | 0 | 3944314 | 152695 | None | PWD DSR 2023-24 Volume-III Page No.31 Item No.5.3 | Providing and applying tack coat with RS1 Bituminous Emulsion using emulsion pressure distributor at the rate of 0.20 kg/m2 on the prepared bituminous surface cleaned with mechanical broom | Sqm | 13.44 | 13.44 | 300.0 | False | None | None | False | None | False | 4032.0 | 0 | 3944315 | 152695 | None | PWD DSR 2023-24 Volume-III Page No.43 Item No.5.31 | Semi Dense Bituminous Concrete: Providing and laying Semi Dense Bituminous Concrete with 40/60 TPH capacity hot mix plant batch type using crushed aggregates of specified grading premixed with bituminous binder VG-30 @ 5% by weight of mix and filler,transported to site,laid over a previously prepared surface with mechanical paver finisher to the required grade,level and alignment and rolled as per MoRTH V revision. | Cum | 11370.24 | 11370.24 | 7.5 | False | None | None | False | None | False | 85276.8 | 0 | 3944316 | 152695 | None | PWD SR 2023-24 Volume-III Page No.17 Item No.3.6 | Construction of sub-grade and earthen shoulders with approved material obtained from borrow pits with all lifts & leads,transporting to site,spreading,grading to required slope and compacted to meet requirement of table No.300-2 | Cum | 552.16 | 552.16 | 13.95 | False | None | None | False | None | False | 7702.632 | 0 | 3944317 | 152695 | None | PWD DSR 2023-24 Volume-III Page No.71 Item No.8.29 | Cable Duct Across the Road Providing and laying of a reinforced cement concrete pipe duct,300 mm dia,across the road (new construction),extending from drain to drain in cuts and toe of slope to toe of slope in fills,constructing head walls at both ends,providing a minimum fill of granular material over top and sides of RCC pipe as per IRC:98-1997,bedded on a 0.3 m thick layer of granular material free of rock pieces,outer to outer distance of pipe at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts,joints to be made leak proof,invert level of duct to be above higher than ground level to prevent entry of water and dirt,all as per IRC: 98-1997 and approved drawings.Single row for one utility service | Mtr | 2212.0 | 2212.0 | 11.25 | False | None | None | False | None | False | 24885.0 | 0 | 3944318 | 152695 | None | PWD SR 2023-24 Vol-IP.No.5.Item No.1.4.1 | Earth work excavation by manual means for drains,canals,waste weir,draft,approach channels,key trenches,foundation of bridges and such simillar works in all kinds of soils ,as per drawing and technical specifications,including setting out,shoring,strutting,barricading,caution lights,removal of stumps and other deleterious matter,excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour,tools & other appurtenaces required to complete the work.-In all kinds of soils Depth upto 1.5 m | Cum | 271.04 | 271.04 | 55.3404 | False | None | None | False | None | False | 14999.462016 | 0 | 3944319 | 152695 | None | PWD SR 2023-24 Vol-I.P.No.15.Item No.2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed,laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators,including all lead & lifts,cost of all materials of quality,labour,Usage charges of machineries,curing,and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork shall be paid separately)-Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6963.04 | 6963.04 | 8.921 | False | None | None | False | None | False | 62117.27984 | 0 | 3944320 | 152695 | None | PWD SR 2023-24 Vol-I P.No.15 Item No.2.2.3 | Providing and laying in position Reinforced cement concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers,well compacted using needle vibrators,including all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes ,labour,Usage charges of machinery,curing and all the other appurtenances required to complete the work as per technical specifications.(The costof steel reinforcement & formwork to be paid separately)- M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7429.12 | 7429.12 | 11.3535 | False | None | None | False | None | False | 84346.51392 | 0 | 3944321 | 152695 | None | PWD SR 2023-24 Vol-I P.No.15 Item No.2.2.3 | Providing and laying in position Reinforced cement concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers,well compacted using needle vibrators,including all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes ,labour,Usage charges of machinery,curing and all the other appurtenances required to complete the work as per technical specifications.(The costof steel reinforcement & formwork to be paid separately)- M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11981.42 | 11981.42 | 0.825 | False | None | None | False | None | False | 9884.6715 | 0 | 3944322 | 152695 | None | PWD SR 2023-24 Vol-I P.No.16 Item No.2.2.3 | Providing and laying in position Reinforced cement concrete for all Super structures of building ,Road works,Water works,Irrigation works & super structure works of bridges upto 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers,well compacted using needle vibrators.The cost includes all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes ,labour,Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement,dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11128.32 | 11128.32 | 3.6162 | False | None | None | False | None | False | 40242.230784 | 0 | 3944323 | 152695 | None | PWD SR 2023-24 Vol-I P.No.16 Item No.2.2.3 | Providing and laying in position Reinforced cement concrete for all Super structures of building ,Road works,Water works,Irrigation works & super structure works of bridges upto 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers,well compacted using needle vibrators.The cost includes all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes ,labour,Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement,dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11821.15 | 11821.15 | 1.8081 | False | None | None | False | None | False | 21373.821315 | 0 | 3944324 | 152695 | None | PWD SR 2023-24 Vol-I P.No.16 Item No.2.2.3 | Providing and laying in position Reinforced cement concrete for all Super structures of building ,Road works,Water works,Irrigation works & super structure works of bridges upto 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers,well compacted using needle vibrators.The cost includes all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes ,labour,Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement,dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11821.15 | 11821.15 | 3.6162 | False | None | None | False | None | False | 42747.64263 | 0 | 3944325 | 152695 | None | PWD SR 2023-24 Vol-I P.No.16 Item No.2.2.3 | Providing and laying in position Reinforced cement concrete for all Super structures of building ,Road works,Water works,Irrigation works & super structure works of bridges upto 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers,well compacted using needle vibrators.The cost includes all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes ,labour,Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement,dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 14592.48 | 14592.48 | 1.9361 | False | None | None | False | None | False | 28252.500528 | 0 | 3944326 | 152695 | None | PWD SR 2023-24 Vol-I P.No.16 Item No.2.2.3 | Providing and laying in position Reinforced cement concrete for all Super structures of building ,Road works,Water works,Irrigation works & super structure works of bridges upto 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers,well compacted using needle vibrators.The cost includes all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes ,labour,Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement,dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11128.32 | 11128.32 | 10.252 | False | None | None | False | None | False | 114087.53664 | 0 | 3944327 | 152695 | None | PWD SR 2023-24 Vol-I P.No.16 Item No.2.2.3 | Providing and laying in position Reinforced cement concrete for all Super structures of building ,Road works,Water works,Irrigation works & super structure works of bridges upto 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers,well compacted using needle vibrators.The cost includes all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes ,labour,Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement,dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates ) | Cum | 10781.9 | 10781.9 | 0.582 | False | None | None | False | None | False | 6275.0658 | 0 | 3944328 | 152695 | None | PWD SR VOL 1 2023-24.I.No.2.11 P.No.18 | Supplying,fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials,machinery,labour,cleaning,straightening,cutting,bending,hooking,laping/welding joints,tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 100191.84 | 100191.84 | 2.897 | False | None | None | False | None | False | 290255.76048 | 0 | 3944329 | 152695 | None | PWD SR 2023-24 Vol-II Page No.9 Item No.5.1.1 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :
Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6284.32 | 6284.32 | 8.4516 | False | None | None | False | None | False | 53112.558912 | 0 | 3944330 | 152695 | None | PWD SR 2023-24 Vol-II Page No.9 Item No.5.1.1 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :
Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6284.32 | 6284.32 | 5.365 | False | None | None | False | None | False | 33715.3768 | 0 | 3944331 | 152695 | None | PWD SR 2023-24 Vol-I P.No.7 Item No.1.9 | Filling available excavated earth (excluding rock) in trenches,plinth,sides of foundations and other similar works etc.in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering,lead up to 50 m and lift upto 1.5 m. | Cum | 297.92 | 297.92 | 26.0236 | False | None | None | False | None | False | 7752.950912 | 0 | 3944332 | 152695 | None | PWD SR 2023-24 Vol-II PAGE NO.9 Item No.5.7 | Providing and Constructing laterite Size Stone Masonry including and conveyance of all materials curing etc.Complete as per specifications IS 3620 1979 having compressive strenght not less than 3.5N mm2 for satuarated dry samples-For Super Structure in CM 1:6. | Cum | 7565.6 | 7565.6 | 20.85 | False | None | None | False | None | False | 157742.76 | 0 | 3944333 | 152695 | None | PWD SR 2023-24 Vol-II P.No.17 Item No.6.33 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg m3 and minimum compressive strength of 4.00 N mm2 conforming to IS 2185 (Part-I)-2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials,labour,scaffolding and curing,usage charges of machinery etc complete as per specifications. | Sqm | 1378.72 | 1378.72 | 17.302 | False | None | None | False | None | False | 23854.61344 | 0 | 3944334 | 152695 | None | PWD SR 2023-24 Vol-II PAGE NO.41 Item No.8.1.2 | Providing 12mm thick cement plaster with cement mortar 1:6 (1 Cement 6 fine sand) including rounding off corners wherever required smooth rendering providing and removing scaffolding including cost of materials labour curing complete as per the direction of engineer incharge of work. | Sqm | 269.92 | 269.92 | 204.3875 | False | None | None | False | None | False | 55168.274 | 0 | 3944335 | 152695 | None | PWD SR 2023-24 Vol-II PAGE NO.41 Item No.8.1.2 | Providing 12mm thick cement plaster with cement mortar 1:6 (1 Cement 6 fine sand) including rounding off corners wherever required smooth rendering providing and removing scaffolding including cost of materials labour curing complete as per the direction of engineer incharge of work. | Sqm | 269.92 | 269.92 | 52.0472 | False | None | None | False | None | False | 14048.580224 | 0 | 3944336 | 152695 | None | PWD SR 2023-24 Vol-II ITEM No.8.6.2,P.No.42 | Providing 20 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick stone masonry including rounding off corners wherever required smooth rendering,providing and removing scaffolding,including cost of materials,labour,curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 480.48 | 480.48 | 135.8901 | False | None | None | False | None | False | 65292.475248 | 0 | 3944337 | 152695 | None | PWD SR VOL II 2023-24.I.No.8.51 P.No.50 | Providing and applying white cement based putty of average thickness 1 mm,of approved brand and manufacturer,over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 112.0 | 112.0 | 256.4347 | False | None | None | False | None | False | 28720.6864 | 0 | 3944338 | 152695 | None | PWD SR VOL II 2023-24.I.No.12.13.2 P.No.100 | Providing Red Salwood frames of doors,windows,clerestory windows,ventilators and other frames,wrought,framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps),but including cost of materials,labour,usage charges complete as per specifications. | Cum | 111552.0 | 111552.0 | 0.329 | False | None | None | False | None | False | 36700.608 | 0 | 3944339 | 152695 | None | PWD SR VOL II 2023-24.I.No.12.57.6 P.No.105 | Providing and fixing flush door shutter made out of solid core block board type,well seasoned ,chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991.from manufacturer complete as per specification.35 mm thick both side commercial | Sqm | 3720.64 | 3720.64 | 7.56 | False | None | None | False | None | False | 28128.0384 | 0 | 3944340 | 152695 | None | PWD SR VOL II 2023-24.I.No.12.60 P.No.105 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc.complete. | No | 1178.24 | 1178.24 | 22.0 | False | None | None | False | None | False | 25921.28 | 0 | 3944341 | 152695 | None | PWD SR VOL II 2023-24.I.No.12.74.1 P.No.107 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc.complete : 125x64x1.90mm | No | 114.24 | 114.24 | 84.0 | False | None | None | False | None | False | 9596.16 | 0 | 3944342 | 152695 | None | PWD SR VOL II 2023-24.I.No.12.58 P.No.105 | Providing and fixing bright finished brass hanging type floor door stopper with necessary screws,etc.complete. | No | 134.4 | 134.4 | 4.0 | False | None | None | False | None | False | 537.6 | 0 | 3944343 | 152695 | None | PWD SR VOL II 2023-24.I.No.12.62 P.No.105 | Providing and fixing chromium plated brass handles of 100 125 mm with necessary screws etc.complete | No | 265.44 | 265.44 | 22.0 | False | None | None | False | None | False | 5839.68 | 0 | 3944344 | 152695 | None | PWD SR VOL II 2023-24.I.No.12.62 P.No.105 | Providing and fixing aluminium tower bolts,ISI marked,anodised anodic coating not less than grade AC 10 as per IS : 1868 transparent or dyed to required colour or shade,with necessary screws etc.complete | No | 265.44 | 265.44 | 33.0 | False | None | None | False | None | False | 8759.52 | 0 | 3944345 | 152695 | None | PWD SR 2023-24 Vol- II P.No.108 Item No.12.83.2 | Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below tolerance plus or minus 1mm ,with wall thickness 2.0 mm plus or minus 0.2 mm ,corners of the door frame to be Jointed with galvanized brackets and stainless steel screws,joints mitred and Plastic welded.The hinge side vertical of the frames reinforced by galvanized M.S.tube of size 19X19 mm and 1mm plus or minus 0.1 mm wall thickness and 3 no.stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineer- in-charge 42x50 mm PVC Extruded section | Mtr | 267.68 | 267.68 | 5.7 | False | None | None | False | None | False | 1525.776 | 0 | 3944346 | 152695 | None | PWD SR 2023-24 Vol- II P.No.105 Item No.12.53 | Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S.tube of 19 gauge thickness,size 19x19mm for stiles and 15x15mm for top & bottom rails,covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail,lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail,Panelling of 5mm thick PVC sheet fitted in the M.S.Frame,Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc.,Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges. | Sqm | 1778.56 | 1778.56 | 1.575 | False | None | None | False | None | False | 2801.232 | 0 | 3944347 | 152695 | None | PWD SR VOL II 2023-24.I.No.12.34 P.No.102 | Providing and fixing in position fully panelled shutters for windows with Honne wood stiles and rails of 25mm.thick,75mm wide in two halves with panels provided with MDF of 12mm thick including cost of materials,labour charges,usage charges complete as per specifications. excluding cost of fixtures | Sqm | 5294.24 | 5294.24 | 8.46 | False | None | None | False | None | False | 44789.2704 | 0 | 3944348 | 152695 | None | PWD SR VOL II 2023-24.I.No.12.51 P.No.104 | KSRB 9-27.1 : Fixing of door frame in an existing opening including embeeding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame,making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m.including cost of materials,labour charges,complete as per specifications. | No | 1137.92 | 1137.92 | 4.0 | False | None | None | False | None | False | 4551.68 | 0 | 3944349 | 152695 | None | PWD SR VOL II 2023-24.I.No.12.52 P.No.104 | Fixing of window frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame,making good the damages to walls and floor as required and disposal of the debries with lead upto 50 m.including cost of materials,labour charges,complete as per specifications. | No | 865.76 | 865.76 | 7.0 | False | None | None | False | None | False | 6060.32 | 0 | 3944350 | 152695 | None | PWD SR VOL II 2023-24.I.No.11.34B P.No.86 | Providing and fixing M.S.grills of required pattern in frames of windows etc.with M.S.flats,square or round bars etc.including priming coat with approved steel primer all complete.Fixed to openings wooden frames with rawl plugs screws etc. | Kg | 204.96 | 204.96 | 177.66 | False | None | None | False | None | False | 36413.1936 | 0 | 3944351 | 152695 | None | PWD SR 2023-24 Vol- II P.No.62 Item No.9.21.2 | Providing and laying Vitrified tiles in floor with different sizes thickness to be specified by the manufacturer ,with water absorption less than 0.08% and conforming to IS:15622,of approved brand & manufacturer,in all colours and shade,laid with cement based high polymer modified quick set tile adhesive water based conforming to IS : 15477,in average 6 mm thickness,including grouting of joints Payment for grouting of joints to be made separately .-Size of Tile 600x600 mm. | Sqm | 1386.56 | 1386.56 | 49.039 | False | None | None | False | None | False | 67995.51584 | 0 | 3944352 | 152695 | None | PWD DWD SR 2023-24,Page No.60,Item No.9.9 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm
thickness to be specified by the manufacturer of 1st quality conforming
to IS : 15622 of approved make in colours such as White,Ivory,Grey,Fume
Red Brown,laid on 20 mm thick cement mortar 1:4 1 Cement : 4 Coarse
sand ,Jointing with grey cement slurry @ 3.3 kg m2 including pointing
the joints with white cement and matching pigment etc.,complete. | Sqm | 1205.12 | 1205.12 | 5.1812 | False | None | None | False | None | False | 6243.967744 | 0 | 3944353 | 152695 | None | PWD SR 2023-24 Vol-II Item 9.39,P.No.65 | Providing skirting,dadooing,rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials,labour,complete as per specifications. | Sqm | 1622.88 | 1622.88 | 26.817 | False | None | None | False | None | False | 43520.77296 | 0 | 3944354 | 152695 | None | PWD SR VOL II 2023-24.I.No.8.33.3 P.No.47 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade.Two coat applied @ 0.90 ltr 10 m² over an under coat of primer applied @ 0.80 ltr 10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil,grease,dirt and foreign matter,cost of materials,labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 155.68 | 155.68 | 8.73 | False | None | None | False | None | False | 1359.0864 | 0 | 3944355 | 152695 | None | PWD SR VOL II 2023-24.I.No.8.33.1 P.No.46 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr 10 m² over and including one coat of Special primer applied @ 0.75 ltr 10 m² with paint of approved quality to give an even shade,after thoroughly brooming the surface to remove all dirt,dust,mortar drops and foreign matter including preparing the surface even and sand paper smooth,cost of materials,labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 176.96 | 176.96 | 204.3875 | False | None | None | False | None | False | 36168.412 | 0 | 3944356 | 152695 | None | PWD SR VOL II 2023-24.I.No.8.33.1 P.No.46 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr 10 m² over and including one coat of Special primer applied @ 0.75 ltr 10 m² with paint of approved quality to give an even shade,after thoroughly brooming the surface to remove all dirt,dust,mortar drops and foreign matter including preparing the surface even and sand paper smooth,cost of materials,labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 176.96 | 176.96 | 52.0472 | False | None | None | False | None | False | 9210.272512 | 0 | 3944357 | 152695 | None | PWD SR VOL II 2023-24.I.No.8.30 P.No.46 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work Two coat applied @ 1.67 ltr 10 m² over and including riming coat of exterior primer applied @ 2.20 kg 10 m² with paint of approved quality to give an even shade,after thoroughly brooming the surface to remove all dirt,dust,mortar drops and foreign matter including preparing the surface even and sand paper smooth,cost of materials,labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 194.88 | 194.88 | 135.8901 | False | None | None | False | None | False | 26482.262688 | 0 | 3944358 | 152695 | None | PWD SR 2023-24 Vol-II,Item No.12.85,P.No109 | Providing & fixing of louvered ventilator made out of multi chambered UPVC Matching to RAL-9016 sections and with minimum TiO2 Titanium Dioxide at 6PHR with TPE Thermo Plastic Elastomer and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame.The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness.Louver clip in Aluminium powder coated in white will be used on the frame along with plastic parts for fixing the 4 mm pin head glass.Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm. The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made | Sqm | 6405.28 | 6405.28 | 0.27 | False | None | None | False | None | False | 1729.4256 | 0 | 3944359 | 152695 | None | PWD SR VOL I 2023-24 I.No.1.6.1 Page No.6 | Earth work excavation for pipelines cables by Manual means upto 600 mm trench width,as per drawing and technical specifications,including setting out,shoring,strutting,barricading,caution lights,removal of stumps and other deleterious matter,including dressing of excavated surfaces,disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m.Filling available excavated earth excluding rock in trenches,plinth,sides of foundations etc.in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour,tools,usage& other appurtenances required to complete the work.In all kinds of soils.Depth upto 1.50m | Cum | 542.08 | 542.08 | 3.72 | False | None | None | False | None | False | 2016.5376 | 0 | 3944360 | 152695 | None | PWD SR VOL 2 2023-24 I.No.1.10 Page No.7 | Refilling available earth around trenches pipelines,cables in layers not exceeding 20 cms in depth,compacting each deposited layer by ramming after watering with a lead upto 50 m ,and lift upto 1.5 m.Including cost of all labour complete as per specifications | Cum | 179.2 | 179.2 | 3.72 | False | None | None | False | None | False | 666.624 | 0 | 3944361 | 152695 | None | PWD SR 2023-24 INo 10.1.7 Page No 113 | Supplying PVC ring tight pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite,rolling and lowering into trenches,laying true to line and level and perfect linking at joints,testing and commissioning,including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials excluding cost of specials with jointing of approved type,with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms.with soft gravel or selected earth available from the excavation etc.complete and giving necessary hydraulic test to the required pressure as per ISS Contractor will make his own arrangements for procuring water for testing etc.for: PVC pipes 110 mm outer dia.,6 kg sqcm & class 3 | Mtr | 460.32 | 460.32 | 11.0 | False | None | None | False | None | False | 5063.52 | 0 | 3944362 | 152695 | None | PWD SR VOL II 2023-24 I.No.13.33.5 PAGE NO.123 | Providing and fixing Chorinated Poly Venyl Chloride CPVC pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings,this includes jointing of pipes and fittings with one step solvent cement,trenching,refilling & testing of joints complete. external work .-40mm nominal doa pipes | Mtr | 534.24 | 534.24 | 10.0 | False | None | None | False | None | False | 5342.4 | 0 | 3944363 | 152695 | None | PWD SR VOL II 2023-24.I.No.13.33.4 PAGE NO.122 | Providing and fixing Chorinated Poly Venyl Chloride CPVC pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings,this includes jointing of pipes and fittings with one step solvent cement,trenching,refilling & testing of joints complete. external work . external work .-32mm nominal doa pipes | Mtr | 416.64 | 416.64 | 10.0 | False | None | None | False | None | False | 4166.4 | 0 | 3944364 | 152695 | None | PWD SR VOL II 2023-24.I.No.13.33.3 PAGE NO.122 | Providing and fixing Chorinated Poly Venyl Chloride CPVC pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings,this includes jointing of pipes and fittings with one step solvent cement,trenching,refilling & testing of joints complete. external work . external work .-25mm nominal dia pipes | Mtr | 331.52 | 331.52 | 6.0 | False | None | None | False | None | False | 1989.12 | 0 | 3944365 | 152695 | None | PWD SR VOL II 2023-24.I.No.13.33.2 Page No 122 | Providing and fixing Chorinated Poly Venyl Chloride CPVC pipes conforming to IS 15778 having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings,this includes jointing of pipes and fittings with one step solvent cement,trenching,refilling & testing of joints complete. external work . external work .-20mm nominal doa pipes | Mtr | 243.04 | 243.04 | 6.0 | False | None | None | False | None | False | 1458.24 | 0 | 3944366 | 152695 | None | PWD SR VOL II 2023-24.I.No.13.4.1,P.No 117 | Providing and fixing Brass full way valve gate with C.I.wheel of approved quality screwed end 25 mm nominal bore | Each | 614.88 | 614.88 | 2.0 | False | None | None | False | None | False | 1229.76 | 0 | 3944367 | 152695 | None | PWD SR VOL II 2023-24.I.No.13.15,P.No 119 | Providing and fixing C.P.brass stop cock concealed of standard design and of approved make conforming to IS:8931 | Each | 812.0 | 812.0 | 2.0 | False | None | None | False | None | False | 1624.0 | 0 | 3944368 | 152695 | None | PWD SR VOL II 2023-24.I.No.13.12,P.No 119 | Providing and fixing C.P.brass bib cock of approved quality conforming to IS:8931 | Each | 711.2 | 711.2 | 2.0 | False | None | None | False | None | False | 1422.4 | 0 | 3944369 | 152695 | None | PWD SR VOL II 2023-24.I.No.14.1.1 P.No 131 | Providing and fixing water closet squatting pan Indian type W.C.pan with 100 mm sand cast Iron P or S trap,10 litre low level white P.V.C.flushing cistern,including flush pipe,with manually controlled device handle lever conforming to IS : 7231,with all fittings and fixtures complete,including cutting and making good the walls and floors wherever required White Vitreous china Orissa pattern W.C.pan of size 580x440 mm with integral type foot rests | Each | 5470.08 | 5470.08 | 1.0 | False | None | None | False | None | False | 5470.08 | 0 | 3944370 | 152695 | None | PWD SR VOL II 2023-24.I.No.14.7.2 P.No 132 | Providing and fixing wash basin with C.I.brackets,15 mm C.P.brass pillar taps,32 mm C.P.brass waste of standard pattern,including painting of fittings and brackets,cutting and making good the walls wherever required: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P.brass pillar tap | Each | 2868.32 | 2868.32 | 1.0 | False | None | None | False | None | False | 2868.32 | 0 | 3944371 | 152695 | None | PWD SR VOL II 2023-24.I.No.14.32.1 P.No 136 | Providing and fixing mirror of superior glass of approved quality and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Circular 450mm Dia | Each | 1218.56 | 1218.56 | 1.0 | False | None | None | False | None | False | 1218.56 | 0 | 3944372 | 152695 | None | PWD SR VOL II 2023-24.I.No.14.40.2 P.No 137 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm,width 78 mm and effective height of 88 mm,weighing not less than 190 g | Each | 555.52 | 555.52 | 1.0 | False | None | None | False | None | False | 555.52 | 0 | 3944373 | 152695 | None | PWD SR VOL II 2023-24.I.No13.45 page no 124 | Providing and fixing trap of self cleansing design with screwed down or hinged grating with or without vent arm complete,including cost of cutting and making good the walls and floors :* 100 mm inlet and 75 mm outlet * Hubless centrifugally cast spun iron epoxy coated inside & outside as per IS:15905 | Each | 1171.52 | 1171.52 | 1.0 | False | None | None | False | None | False | 1171.52 | 0 | 3944374 | 152695 | None | BWSSB SR 2023-24.Item No.16.9 Page No.191 | Constructing brick masonry chamber of internal dimension 600x600 mm and depth of 600 mm inner dimensions with modular bricks of CD 75 in cement mortar 1:6,bed concrete 150 mm thick with 1:3:6,lastering 12 mm thick with cement mortar 1:4,CC 1:2:4 coping 75 mm thick for fixing CI cover & frame etc.excluding the cost of CI frame and cover.Inspection Chamber of Size 450 x 450 x 450 mm pection Chamber of Size 450 x 450 x 450 mm | Each | 6108.48 | 6108.48 | 2.0 | False | None | None | False | None | False | 12216.96 | 0 | 3944375 | 152695 | None | PWD SR VOL II 2023-24.I.No.13.8.2.2 Page No.118 | Providing and fixing unplasticised PVC connection pipe with brass unions : 45 cm length 20 mm nominal bore | Each | 123.2 | 123.2 | 1.0 | False | None | None | False | None | False | 123.2 | 0 | 3944376 | 152695 | None | PWD SR VOL II 2023-24.I.No.14.29 Page No.136 | Providing and fixing 100 mm sand cast Iron grating for gully trap.For Bathrooms,Urinals,Toilet rooms and hand wash | Each | 52.64 | 52.64 | 1.0 | False | None | None | False | None | False | 52.64 | 0 | 3944377 | 152695 | None | PWD SR VOL II 2023-24.I.No.13.34 Page No.123 | Providing and placing on terrace at all floor levels polyethylene water storage tank,IS : 12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. | Ltr | 10.08 | 10.08 | 1000.0 | False | None | None | False | None | False | 10080.0 | 0 | 3944378 | 152695 | None | PWD SR VOL II 2023-24.I.No.13.66 Page no.123 | Cutting holes up to 30x30 cm in walls including making good the same: With common burnt clay F.P.S. non modular bricks Wall bores in Brick masonry | Each | 361.76 | 361.76 | 2.0 | False | None | None | False | None | False | 723.52 | 0 | 3944379 | 152695 | None | PWD SR VOL II 2023-24.I.No.13.37 | Cutting holes up to 15x15 cm in R.C.C.floors and roofs for passing drain pipe etc.and repairing the hole after insertion of drain pipe etc.with cement concrete 1:2:4 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ,including finishing complete so as to make it leak proof. | Each | 350.56 | 350.56 | 2.0 | False | None | None | False | None | False | 701.12 | 0 | 3944380 | 152695 | None | Page No.2 Item No.1.8.2 Electrical SR 2023-24 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends,junction box,elbows,screws at an interval of 300 mm.etc.as required.25mm -25mm | Mtr | 35.0 | 35.0 | 150.0 | False | None | None | False | None | False | 5250.0 | 0 | 3944381 | 152695 | None | Page No.3 Item No.1.2.2 | Supplying heavy gauge PVC conduit pipe ……mm dia.mm thick confirming to IS 2509 with suitable size bends,metal PVC junction boxes,adhesive paste etc.,and running before concreting the slab.The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures,run with 18SWG GI fish wire wherever necessary -25mm Square box | Each | 78.0 | 78.0 | 23.0 | False | None | None | False | None | False | 1794.0 | 0 | 3944382 | 152695 | None | Page No.5 Item No.2.1.1 | Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit casing capping using 1100V grade,COPPER conductor flexible multistrand FRLS PVC insulated,2 X1.5Sq.mm Cable confirming to the GTP,with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet gang box,the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block.complete for each outlet.GROUP A.-Short point upto 3Mtr from tapping point to out let via switch | Point | 285.0 | 285.0 | 50.0 | False | None | None | False | None | False | 14250.0 | 0 | 3944383 | 152695 | None | Page No.5 Item No.2.1.2 | Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit casing capping using 1100V grade,COPPER conductor flexible multistrand FRLS PVC insulated,2 X1.5Sq.mm Cable confirming to the GTP,with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet gang box,the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block.complete for each outlet.GROUP A.-Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch | Point | 394.0 | 394.0 | 12.0 | False | None | None | False | None | False | 4728.0 | 0 | 3944384 | 152695 | None | Page No.5 Item No.2.1.4 | Point wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC Conduit casing capping using 1100V grade,COPPER conductor flexible multistrand FRLS PVC insulated,2 X1.5Sq.mm Cable confirming to the GTP,with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet gang box,the other end of the wires shall be terminated with sufficient loose length in a wood PVC round block.complete for each outlet.GROUP A.-Two outlet in a row,above 3Mtr upto 6Mtr from tapping point to out let via switches | Point | 708.0 | 708.0 | 9.0 | False | None | None | False | None | False | 6372.0 | 0 | 3944385 | 152695 | None | Page No.6 Item No.2.3.2 | Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade,multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A.-1.5 sqmm | Mtr | 26.0 | 26.0 | 150.0 | False | None | None | False | None | False | 3900.0 | 0 | 3944386 | 152695 | None | Page No.5& 6 Item No.2.3.3 | Wiring for lighting power circuit using one of FRLS PVC insulated 1100V grade,multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A.-2.5 sqmm | Mtr | 42.0 | 42.0 | 180.0 | False | None | None | False | None | False | 7560.0 | 0 | 3944387 | 152695 | None | 11.5.2 | Supply of round square recess surface mounted rollingtype LED Down light with.W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powdercoated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained bycircular wire spring,with Life of 25000 burning hours & 70% lumen maintenance with CRI greather than 80.Power Input: 220-240V@50 60Hz & Power factor greather than 0.9 along with CE approved.2years Warranty against any manufacturing defect working understandard electrical condition-LED square or round down light 10-12W | No | 885.0 | 885.0 | 5.0 | False | None | None | False | None | False | 4425.0 | 0 | 3944388 | 152695 | None | Page No.8 Item No.3.4.5 & 3.4.3 | Supplying and fixing surface flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick C.C wall,including necessary rawl plugs,Machine NF screws etc.,complete.-8Way | Each | 261.0 | 261.0 | 6.0 | False | None | None | False | None | False | 1566.0 | 0 | 3944389 | 152695 | None | Page No.8 Item No.3.4.5 & 3.4.3 | Supplying and fixing surface flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick C.C wall,including necessary rawl plugs,Machine NF screws etc.,complete.4-5 way | Each | 177.0 | 177.0 | 6.0 | False | None | None | False | None | False | 1062.0 | 0 | 3944390 | 152695 | None | Item No.3.5.5 & 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws,bolts nuts etc.,complete on the existing metal PVC box.-8 Module | Each | 284.0 | 284.0 | 20.0 | False | None | None | False | None | False | 5680.0 | 0 | 3944391 | 152695 | None | Item No.3.5.5 & 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws,bolts nuts etc.,complete on the existing metal PVC box.-4 Module | Each | 175.0 | 175.0 | 20.0 | False | None | None | False | None | False | 3500.0 | 0 | 3944392 | 152695 | None | Item No.3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6Amps one way Switch | Each | 102.0 | 102.0 | 30.0 | False | None | None | False | None | False | 3060.0 | 0 | 3944393 | 152695 | None | Item No.3.6.3 | Spplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6Amps 3way socket | Each | 171.0 | 171.0 | 10.0 | False | None | None | False | None | False | 1710.0 | 0 | 3944394 | 152695 | None | Item No.3.6.9 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-32Amps DP switch | Each | 326.0 | 326.0 | 2.0 | False | None | None | False | None | False | 652.0 | 0 | 3944395 | 152695 | None | Item No.5.7.2- | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden panel using necessary nuts,bolts and washers.-32 A | Each | 241.0 | 241.0 | 2.0 | False | None | None | False | None | False | 482.0 | 0 | 3944396 | 152695 | None | Item no 5.18.4-6 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve,indicator ON OFF,energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.-32 A DP | Each | 739.0 | 739.0 | 1.0 | False | None | None | False | None | False | 739.0 | 0 | 3944397 | 152695 | None | Item no 12.57 | Supplying fixing and wiring earth electrode for grounding of lifts,transformers,DG sets etc.using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover.The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber.The connection from the electrode is to be established through GI strip using GI bolts and nuts.-400x400x400mm | Each | 4256.0 | 4256.0 | 4.0 | False | None | None | False | None | False | 17024.0 | 0 | 3944398 | 152695 | None | Item no 6.3.1 | Supplying capacitor type ceiling fan complete with down rod blades,shackle,canopies etc,for operation on 230 V,50 cycles.Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.-48" Sweep 1200 mm Regular model | Each | 2984.0 | 2984.0 | 4.0 | False | None | None | False | None | False | 11936.0 | 0 | 3944399 | 152695 | None | Item no 11.3.2 | Supplying of.feet -PVC Batten with integrated LED tube.W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greather than 80.Power Input: 220-240V@ 50 60Hz & Power factor greather than 0.9 along with CE approved.2 years Warranty against any manufacturing defect working under standard electrical condition -LED light fitting 1 x 4 feet-20 22 W | Each | 690.0 | 690.0 | 6.0 | False | None | None | False | None | False | 4140.0 | 0 | 3944400 | 152695 | None | 5.6.4 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws -12"X12"X2" | Each | 181.0 | 181.0 | 1.0 | False | None | None | False | None | False | 181.0 | 0 | 3944401 | 152695 | None | 11.11.3 | Supplying & fixing of retrofit type-LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K,CRI greather than 70%.efficacy greather than 80 lumen per W,life greather than 25000burning hours and Compliance to IS 10322 IEC 60598,LM 79 & LM 80.The LED are driven by HF electronic driver integrated in the system,with PF greather than 0.95,power loss should less than 5% of lamp Wage.,short circuit & open circuit protection to be integratedin the circuit,THD less than 20%,Life as per LM 79.Theoperating input voltage should be between 130 to 275 V.BISApproved and Tested by NABL CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.-7W,6500K | Each | 149.0 | 149.0 | 60.0 | False | None | None | False | None | False | 8940.0 | 0 | 3944402 | 152695 | None | ESCOMs SR Sl no.198 I.No 32.02 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated,PVC extruded Inner sheath armoured UG LT cable as per IS-1554 Part-1 or IS-7098 Part-1,Armouring strip thickness in average +5% and resistivity 14 Ohms Kms Max as per IS-3975-4 core 35 sqmm.-a 2 core 10 sqmm. | Mtr | 79.23 | 79.23 | 125.0 | False | None | None | False | None | False | 9903.75 | 0 | 3944403 | 152695 | None | ESCOMs SR Sl no.198 I.No 32.02 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe stoneware pipe on wall on pole as required.In existing trench duct.On wall Structure.-a 2 core 10 sqmm. | Mtr | 79.23 | 79.23 | 35.5 | False | None | None | False | None | False | 2812.665 | 0 |
| 1725878728000 | 0 | None | None | Other Works | Expenditure required for completion of building works being constructed under Purakkarika Grabhagya Yojana for the welfare of civil servants. | 500353.74 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3944404 | 152696 | None | PWD SR-2023-24-Vol.2 - Page No. 26 - Item No. 7.34 | Providing and fixing 6mm Clear/opal white/solar bronze/blue/green tinted Multi wall poly carbonate sheet for Tubular structure. The work including cost of all materials, labour charges and usage charges of machinery for cutting, welding, grinding and erection equipments, with all lead, transportation, loading and unloading and all other incidental charges etc. complete as per specification and directions of the Engineer in charge of the work. | Sqm | 3500.0 | 3500.0 | 62.0 | False | None | None | False | None | False | 217000.0 | 0 | 3944405 | 152696 | None | PWD SR-2023-24-Vol.2-Page No. 69 - Item No. 10.1.1 | Providing and fixing 18 mm thick gang saw cut granite of any color and shade, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch up, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels.Area of the slab upto 0.50 m2 | Sqm | 4486.72 | 4486.72 | 8.64 | False | None | None | False | None | False | 38765.2608 | 0 | 3944406 | 152696 | None | PWD SR-2023-24-Vol.2-Page No. 71 - Item No. 10.14 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg/m2, including pointing in white cement mixed with pigment of matching shade complete. | Sqm | 1260.84 | 1260.84 | 14.4 | False | None | None | False | None | False | 18156.096 | 0 | 3944407 | 152696 | None | PWD SR-2023-24-Vol.2-Page No. 108 - Item No.12.84 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets -grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware& single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) | Sqm | 5625.76 | 5625.76 | 23.04 | False | None | None | False | None | False | 129617.5104 | 0 | 3944408 | 152696 | None | PWD SR-2023-24 - Vol. 2 -Page 62- Item No.9.21.1 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 500x500 mm- (Anti-Skid Tiles) | Sqm | 1317.12 | 1317.12 | 12.0599 | False | None | None | False | None | False | 15884.335488 | 0 | 3944409 | 152696 | None | PWD SR-2023-24 - Vol. 2 -Page 62- Item No.9.21.1 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 500x500 mm- (Anti-Skid Tiles)-1st Floor | Sqm | 1328.88 | 1328.88 | 12.0599 | False | None | None | False | None | False | 16026.159912 | 0 | 3944410 | 152696 | None | PWD SR-2023-24 - Vol. 2 -Page 62- Item No.9.21.1 | Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 500x500 mm- (Anti-Skid Tiles)- 2nd Floor | Sqm | 1340.64 | 1340.64 | 12.0599 | False | None | None | False | None | False | 16167.984336 | 0 | 3944411 | 152696 | None | PWD SR-2023-24-Vol. 2-Page No.131-Item No.14.3.1 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C. pan with ISI marked white solid plastic seat and lid | No | 6813.78 | 6813.78 | 4.0 | False | None | None | False | None | False | 27255.12 | 0 | 3944412 | 152696 | None | PWD SR-2023-24-Vol.2-Page No.136-Item No.14.29 | Providing and fixing 100 mm sand cast Iron grating for gully trap | No | 53.58 | 53.58 | 4.0 | False | None | None | False | None | False | 214.32 | 0 | 3944413 | 152696 | None | PWD SR-2023-24-Vol.2-Page No.117-Item No.13.1.1. | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : | No | 693.12 | 693.12 | 4.0 | False | None | None | False | None | False | 2772.48 | 0 | 3944414 | 152696 | None | Page No.113-ItemNo.10.1.1 | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: | Mtr | 54.72 | 54.72 | 15.0 | False | None | None | False | None | False | 820.8 | 0 | 3944415 | 152696 | None | PWD SR-2023-24-Vol.2-Page No. 117-Item No. 13.1.1. | Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: | No | 76.38 | 76.38 | 15.0 | False | None | None | False | None | False | 1145.7 | 0 | 3944416 | 152696 | None | PWD SR-2023-24-Vol.2-Page No. 109 - Item No.12.85 | Providing & fixing of louvered ventilator made out of multi chambered PVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made)Providing & fixing of louvered ventilator made out of multi chambered PVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) | Sqm | 6405.28 | 6405.28 | 2.16 | False | None | None | False | None | False | 13835.4048 | 0 | 3944417 | 152696 | None | PWD SR-2023-24-Vol.2-Page No. 104 - Item No.12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | Sqm | 356.16 | 356.16 | 7.56 | False | None | None | False | None | False | 2692.5696 | 0 |
| 1725878728000 | 0 | None | None | Other Works | Improvements of Civil and other works for TP Yellapura limits | 1200169.23 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3944418 | 152697 | None | PWD SR-2023-24-Vol.1-Page No.8-Item No.1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m,as per drawing and technical specifications,including setting out,shoring,strutting,barricading,caution lights,including dressing of excavated surfaces,disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour,tools,usage of machinery & other appurtenaces required to complete the work.In all kinds of soils Depth upto 3 m | Cum | 114.24 | 114.24 | 218.776 | False | None | None | False | None | False | 24992.97024 | 0 | 3944419 | 152697 | None | PWD SR-2023-24-Vol.1-Page No.7-Item No.1.9 | Filling available excavated earth (excluding rock) in trenches,plinth,sides of foundations and other similar works etc.in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering,lead up to 50 m and lift upto 1.5 m. | Cum | 297.92 | 297.92 | 57.23 | False | None | None | False | None | False | 17049.9616 | 0 | 3944420 | 152697 | None | PWD SR-2023-24-Vol.1-Page No.15-Item No.2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed,laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators,including all lead & lifts,cost of all materials of quality,labour,Usage charges of machineries,curing,and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6963.04 | 6963.04 | 23.632 | False | None | None | False | None | False | 164550.56128 | 0 | 3944421 | 152697 | None | PWD SR-2023-24-Vol.1-Page No.16-Item No.2.4.2 | Providing and laying in position Reinforced cement concrete for all Sub structures of building,Irrigation works,Sub structure works of bridges,Drain works & other parallel works from 0.50m to 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers,laid in layers,well compacted using needle vibrators,providing weep holes wherever necesary,including all lead & lifts,cost of all materials of quality,confirming to the requirements of relevant IS codes,labour,Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7294.21 | 7294.21 | 23.95 | False | None | None | False | None | False | 174696.3295 | 0 | 3944422 | 152697 | None | PWD SR-2023-24-Vol.1-Page No.16-Item No.2.4.2 | Providing and laying in position Reinforced cement concrete for all Sub structures of building,Irrigation works,Sub structure works of bridges,Drain works & other parallel works from 0.50m to 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers,laid in layers,well compacted using needle vibrators,providing weep holes wherever necesary,including all lead & lifts,cost of all materials of quality,confirming to the requirements of relevant IS codes,labour,Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9560.37 | 9560.37 | 32.25 | False | None | None | False | None | False | 308321.9325 | 0 | 3944423 | 152697 | None | PWD SR-2023-24-Vol.1-Page No.18-Item No.2.11 | Supplying,fitting and placing TMT FE 550/550D Steel Reinforcement including cost of all materials,machinery,labour,cleaning,straightening,cutting,bending,hooking,laping/welding joints,tying with binding wire/soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 88492.32 | 88492.32 | 3.7038 | False | None | None | False | None | False | 327757.854816 | 0 | 3944424 | 152697 | None | PWD SR-2023-24-Vol.1-Page No.17-Item No.2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building ,Road works,Water works,Irrigation works & super structure works of bridges upto 3.50 m height.The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers,well compacted using needle vibrators.The cost includes all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes ,labour,Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement,dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7664.16 | 7664.16 | 13.799 | False | None | None | False | None | False | 105757.74384 | 0 | 3944425 | 152697 | None | PWD SR-2023-24-Vol.1-Page No.16-Item No.2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building ,Road works,Water works,Irrigation works & super structure works of bridges upto 3.50 m height.The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers,well compacted using needle vibrators.The cost includes all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes ,labour,Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement,dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11496.24 | 11496.24 | 2.3399 | False | None | None | False | None | False | 26900.051976 | 0 | 3944426 | 152697 | None | PWD SR-2023-24-Vol.1-Page No.16-Item No.2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building ,Road works,Water works,Irrigation works & super structure works of bridges upto 3.50 m height.The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers,well compacted using needle vibrators.The cost includes all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes ,labour,Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement,dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8277.29 | 8277.29 | 0.7799 | False | None | None | False | None | False | 6455.458471 | 0 | 3944427 | 152697 | None | PWD SR-2023-24-Vol.1-Page No.11-Item No.1.23 | Providing and Filling in foundation with granite/trap broken metal 100mm and down size with approved M-Sand including hand packing,ramming,watering including cost of all materials and labour with all lead and lift complete as per specifications. | Cum | 3003.84 | 3003.84 | 2.2319 | False | None | None | False | None | False | 6704.270496 | 0 | 3944428 | 152697 | None | PWD SR-2023-24-Vol.3-Page No.121-Item No.13.2A | Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications.(Batching Plant) | Cum | 15647.52 | 15647.52 | 2.34 | False | None | None | False | None | False | 36615.1968 | 0 | 3944429 | 152697 | None | PWD SR-2023-24-Vol.3-Page No.123-Item No.13.14 | Painting on concrete surface Providing and applying 2 coats of water based cement paint to unplastered concrete surface after cleaning the surface of dirt,dust,oil,grease,efflorescence and applying paint @ of 1 litre for 2 m2. | Sqm | 94.08 | 94.08 | 3.9 | False | None | None | False | None | False | 366.912 | 0 |
| 1725878728000 | 0 | None | None | Other Works | Construction work of disabled community building under Town Panchayat (first phase) | 899954.76 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3944430 | 152698 | None | PWD SR 1.5.1,2023-24,Page No . 6 Vol | Earth work excavation by manual means for drains,canals,waste weir draft,approach channels,key trench,foundation of Bridges and such similar works,as per drawing and technical specifications,including setting out,shoring,strutting,barricading,caution lights,excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour,tools,usage & other appurtenances required to complete the work. | Cum | 334.88 | 334.88 | 41.406 | False | None | None | False | None | False | 13866.04128 | 0 | 3944431 | 152698 | None | KPWD SR Vol-I 2.1.3,2023-24,Vol 1 Page 15 | Providing and laying in position plain cement concrete for levelling course for all works in foundation . The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed,laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators,including all lead & lifts,cost of all materials of quality,labour,Usage charges of machinery,curing,and all the other appurtenances required to complete the work as per technical specifications.Mix 1:3:6 (M10) Using 40 mm and down size graded crushed coarse aggregates. | Cum | 6707.68 | 6707.68 | 6.5778 | False | None | None | False | None | False | 44121.777504 | 0 | 3944432 | 152698 | None | KPWD SR Vol-2,5.1.1,Page No 9 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6284.32 | 6284.32 | 18.0225 | False | None | None | False | None | False | 113259.1572 | 0 | 3944433 | 152698 | None | KPWD SR Vol-1 Page No.15 I.No. 2.2.3 | Providing and laying in position Reinforced cement concrete for all Foundation works . The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers,well compacted using needle vibrators,including all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes,labour,Usage charges of machinery,curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates. | Cum | 7429.12 | 7429.12 | 3.2207 | False | None | None | False | None | False | 23926.966784 | 0 | 3944434 | 152698 | None | KPWD SR Vol-1 Page No.16 I.No. 2.3.1 | Providing and laying in Reinforced cement concrete for all Basement & surface level works,return walls,retaining walls,sunken floors etc . The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers,laid in layers not exceeding 150 mm thickness,well compacted using needle vibrators,providing weep holes wherever necesary,including all lead & lifts,cost of all materials of quality,labour,Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications . M20 Design Mix Using 20 mm and down size graded crushed coarse aggregates. | Cum | 10423.84 | 10423.84 | 2.3144 | False | None | None | False | None | False | 24124.935296 | 0 | 3944435 | 152698 | None | KPWD SR Vol-1,P.No.16,I.No.2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building,Road works,Water works,Irrigation works & super structure works of bridges upto 3.50 m height . The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers,well compacted using needle vibrators . The cost includes finsishing concrete structure in line,all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes,labour,Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 12272.28 | 12272.28 | 1.44 | False | None | None | False | None | False | 17672.0832 | 0 | 3944436 | 152698 | None | KPWD SR Vol-1,P.No.16,I.No.2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building,Road works,Water works,Irrigation works & super structure works of bridges upto 3.50 m height . The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers,well compacted using needle vibrators . The cost includes finsishing concrete structure in line,all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes,labour,Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications. | Cum | 11579.9 | 11579.9 | 2.2654 | False | None | None | False | None | False | 26233.10546 | 0 | 3944437 | 152698 | None | KPWD SR Vol-1,P.No.17,I.No.2.5.1 | Providing and laying in position Reinforced cement concrete for all Super structures of building,Road works,Water works,Irrigation works & super structure works of bridges upto 3.50 m height . The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers,well compacted using needle vibrators . The cost includes finsishing concrete structure in line,all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes,labour,Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications. | Cum | 10887.52 | 10887.52 | 6.7399 | False | None | None | False | None | False | 73380.796048 | 0 | 3944438 | 152698 | None | PWD SR VOL II 2023-24.I.No.2.11 P.No.18 | Supplying,fitting and placing TMT FE 550/550D Steel Reinforcement including cost of all materials,machinery,labour,cleaning,straightening,cutting,bending,hooking,laping/welding joints,tying with binding wire/soft annealed steel wire and other ancilary operations complete as per drawing and technical specification | Tonne | 100191.84 | 100191.84 | 1.0793 | False | None | None | False | None | False | 108137.052912 | 0 | 3944439 | 152698 | None | KPWD SR VoII- Page No.13,I.No . 6.3 | Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials,labour,scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 9938.88 | 9938.88 | 12.7953 | False | None | None | False | None | False | 127170.951264 | 0 | 3944440 | 152698 | None | KPWD SR,Vol-1,1.9,P.No.35,2023-24 | Filling available excavated earth (excluding rock) in trenches,plinth,sides of foundations and other similar works etc . in layers not exceed ing 20cm in depth,consolidating each deposited layer by ramming and watering,lead up to 50 m and lift upto 1.5 m. | Cum | 297.92 | 297.92 | 28.6749 | False | None | None | False | None | False | 8542.826208 | 0 | 3944441 | 152698 | None | KPWD SR,Vol-2 P.No.41,I.No.8.1.1,2023-24 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering,providing and removing scaffolding,includ ing cost of materials,labour,curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 285.6 | 285.6 | 66.42 | False | None | None | False | None | False | 18969.552 | 0 | 3944442 | 152698 | None | KPWD SR,Vol-2,P.No.42,I.No.8.8,2023-24 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering,providing and removing scaffolding,including cost of materials,labour,curing complete as per specifications and asper directions of Engineer-in-charge. | Sqm | 415.52 | 415.52 | 102.7719 | False | None | None | False | None | False | 42703.779888 | 0 | 3944443 | 152698 | None | KPWD SR,Vol-2,P.No.43,I.No.8.10,2023-24 | Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) including rounding off corners wherever required smooth rendering,providing and removing scaffolding,including cost of materi als,labour,curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 236.32 | 236.32 | 51.5112 | False | None | None | False | None | False | 12173.126784 | 0 | 3944444 | 152698 | None | KPWD SR,Vol-2,P.No.45,I.No.8.25,2023-24 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt,dust,mortar drops and foreign matter including preparing the surface even and sand paper smooth,cost of materials,labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 153.44 | 153.44 | 117.9312 | False | None | None | False | None | False | 18095.363328 | 0 | 3944445 | 152698 | None | KPWD SR,Vol-2,P.No.45,I.No.8.29,2023-24 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt,dust,mortar drops and foreign matter including preparing the surface even and sand paper smooth,cost of materials,labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 316.96 | 316.96 | 102.771 | False | None | None | False | None | False | 32574.29616 | 0 | 3944446 | 152698 | None | KPWD SR,Vol-2,P.No.60,I.No.9.12.2,2023-24 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622,of approved make,in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),jointing with grey cement slurry @ 3.3 kg/m2 including grouting the joints with white cement and matching pigments etc.,complete.Size of Tile 600x600 mm. | Sqm | 1282.4 | 1282.4 | 35.75 | False | None | None | False | None | False | 45845.8 | 0 | 3944447 | 152698 | None | KPWD SR,Vol-2,P.No.61,I.No.9.19,2023-24 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer),with water absorption less than 0.08% and conforming to IS: 15622,of approved brand & manufacturer,in all colours and shade,in skirting,riser,treads of steps,laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477,in average 6 mm thickness,including grouting of joints as per direction of Engineer in charge. | Sqm | 1313.76 | 1313.76 | 2.4 | False | None | None | False | None | False | 3153.024 | 0 | 3944448 | 152698 | None | KPWD SR,Vol-2,P.No.99,I.No.12.12,2023-24 | Providing Mathi/Nandi wood frames of doors,windows,clerestory windows,ventilators and other frames,wrought,framed or assembled including making plaster groves ( excluding cost of cement concrete and side clamps),but including cost of materials,labour,usage charges complete as per specifications. | Sqm | 139106.24 | 139106.24 | 0.05 | False | None | None | False | None | False | 6955.312 | 0 | 3944449 | 152698 | None | KPWD SR,Vol-2,P.No.100,I.No.12.21,2023-24 | Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with,stiles and rails of 30mm . thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials,labour,usage charges complete as per specifications . (excluding cost of fixtures ) | Sqm | 6431.04 | 6431.04 | 1.9 | False | None | None | False | None | False | 12218.976 | 0 | 3944450 | 152698 | None | KPWD SR,Vol-2,P.No.104,I.No.12.51,2023-24 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame,making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m . including cost of materials,labour charges,complete as per specifications. | No | 1137.92 | 1137.92 | 1.0 | False | None | None | False | None | False | 1137.92 | 0 | 3944451 | 152698 | None | KPWD SR,Vol-2,P.No.105,I.No.12.65,2023-24 | Providing and fixing magnetic catcher of approved quality in cupboard/ward robe shutters,including fixing with necessary screws etc . complete. | No | 66.08 | 66.08 | 1.0 | False | None | None | False | None | False | 66.08 | 0 | 3944452 | 152698 | None | KPWD SR,Vol-2,P.No.107,I.No.12.76.2,2023-24 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc . complete 200x10mm. | No | 392.0 | 392.0 | 1.0 | False | None | None | False | None | False | 392.0 | 0 | 3944453 | 152698 | None | KPWD SR,Vol-2,P.No.105,I.No . 12.60,2023-24 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc . complete. | No | 1178.24 | 1178.24 | 1.0 | False | None | None | False | None | False | 1178.24 | 0 | 3944454 | 152698 | None | KPWD SR,Vol-2,P.No.107,I.No.12.74.2,2023-24 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc . complete.: 100x58x1.9mm | No | 101.92 | 101.92 | 3.0 | False | None | None | False | None | False | 305.76 | 0 | 3944455 | 152698 | None | KPWD SR,Vol-2,P.No.108,I.No.12.79.2,2023-24 | Providing and fixing bright finished brass handles with screws etc . complete:Brass handles 100 mm with plate 150x32 mm . | No | 258.72 | 258.72 | 2.0 | False | None | None | False | None | False | 517.44 | 0 | 3944456 | 152698 | None | KPWD SR,Vol-2,P.No.86,I.No.11.34B.,2023-24 | Providing and fixing M.S . grills of required pattern in frames of win dows etc . with M.S . flats,square or round bars etc . including priming coat with approved steel primer all complete . Fixed to openings/wooden frames with rawl plugs screws etc . Considering 10kg for one Window | Kg | 204.96 | 204.96 | 152.0 | False | None | None | False | None | False | 31153.92 | 0 | 3944457 | 152698 | None | KPWD SR,Vol-2,P.No.88,I.No.11.35.2.2.,2023-24 | Providing and fixing aluminium work for doors,windows,ventilators and partitions with extruded built up standard tubular sections/appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285,fixing with dash fasteners of required dia and size,including necessary filling up the gaps at junctions,i.e . at top,bottom and sides with required EPDM rubber/neoprene gasket etc . Aluminium sections shall be smooth,rust free,straight,mitred and jointed mechanically wherever required including cleat angle,Aluminium snap beading for glazing/paneling,C.P . brass/stainless steel screws,all complete as per architectural drawings and the directions of Engineer-in-charge . (Glazing,paneling and dash fasteners to be paid for separately) :For shutters of doors,windows & ventilators including providing and fixing hinges/pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron) including cost of materials,labour,usage charges of machinery complete as per specifications. | Kg | 639.52 | 639.52 | 72.0 | False | None | None | False | None | False | 46045.44 | 0 | 3944458 | 152698 | None | KPWD SR,Vol-2,P.No.89,I.No.11.37.1,2023-24 | Providing and fixing glazing in aluminium door,window,ventilator shutters and partitions etc . with EPDM rubber/neoprene gasket etc . complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/m²) including cost of materials,labour,usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge . ( | Sqm | 1106.56 | 1106.56 | 6.3 | False | None | None | False | None | False | 6971.328 | 0 | 3944459 | 152698 | None | KPWD SR,Vol-2,P.No.48,I.No.8.41,2023-24 | Painting with synthetic enamel paint of approved brand and manu facture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt,dust,mortar drops and foreign matter including preparing the surface even and sand paper smooth,cost of materials,labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 187.04 | 187.04 | 2.52 | False | None | None | False | None | False | 471.3408 | 0 | 3944460 | 152698 | None | KPWD ELECTRICAL SR 1.2.8,2023-24 | Supplying heavy gauge PVC conduit pipe ……mm dia .......mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes,adhesive paste etc.,and running before concreting the slab . The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures,run with 18SWG GI fish wire wherever necessary . 19/20 mm dia 2 mm thick | Mtr | 73.92 | 73.92 | 5.0 | False | None | None | False | None | False | 369.6 | 0 | 3944461 | 152698 | None | KPWD ELECTRICAL SR 1.2.1,2023-24 | Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming toIS-694: and latest amendments) with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box,the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block . complete for each outlet . Medium point above 3m upto 6m from tapping point to out let via switch | No | 441.28 | 441.28 | 2.0 | False | None | None | False | None | False | 882.56 | 0 | 3944462 | 152698 | None | KPWD ELECTRICAL SR 3.5.1,2023-24 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos . of machine screws,bolts nuts etc.,complete on the existing metal/PVC box . 1 to 2 Module 1to 3 module | No | 153.44 | 153.44 | 4.0 | False | None | None | False | None | False | 613.76 | 0 | 3944463 | 152698 | None | KPWD ELECTRICAL SR 3.13.1,2023-24 | Supplying and fixing of metal clad industrial plugs and sockets . 2pole+earth 250V PLUG-16A | No | 434.29 | 434.29 | 3.0 | False | None | None | False | None | False | 1302.87 | 0 | 3944464 | 152698 | None | Item No . 1.8.2 Electrical SR 2023-24 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends,junction box,elbows,screws at an interval of 300 mm etc.as required.25mm | Mtr | 35.0 | 35.0 | 50.0 | False | None | None | False | None | False | 1750.0 | 0 | 3944465 | 152698 | None | Page No.3 Item No . 1.2.2 | Supplying heavy gauge PVC conduit pipe mm dia mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes,adhesive paste etc.,and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures,run with 18SWG GI fish wire wherever necessary 25mm Square box | Each | 78.0 | 78.0 | 15.0 | False | None | None | False | None | False | 1170.0 | 0 | 3944466 | 152698 | None | Page No . 5 Item No.2.1.1 | Point wiring using Copper wire with switch . Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 1100V grade,COPPER conductor flexible multistrand FRLS PVC insulated,2 X1.5Sq.mm Cable confirming to the GTP,with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box,the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block . complete for each outlet . GROUP A.Short point upto 3Mtr from tapping point to out let via switch | Point | 285.0 | 285.0 | 10.0 | False | None | None | False | None | False | 2850.0 | 0 | 3944467 | 152698 | None | Page No . 5 Item No.2.1.2 | Point wiring using Copper wire with switch . Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 1100V grade,COPPER conductor flexible multistrand FRLS PVC insulated,2 X1.5Sq.mm Cable confirming to the GTP,with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box,the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block . complete for each outlet . GROUP A.Medium point above 3Mtr upto 6Mtr from tapping point to out let via switch | Point | 394.0 | 394.0 | 2.0 | False | None | None | False | None | False | 788.0 | 0 | 3944468 | 152698 | None | Page No . 5 Item No.2.1.3 | Point wiring using Copper wire with switch . Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 1100V grade,COPPER conductor flexible multistrand FRLS PVC insulated,2 X1.5Sq.mm Cable confirming to the GTP,with a 6Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box,the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block . complete for each outlet . GROUP A.Two outlet in a row,above 3Mtr upto 6Mtr from tapping point to out let via switches | Point | 708.0 | 708.0 | 1.0 | False | None | None | False | None | False | 708.0 | 0 | 3944469 | 152698 | None | Page No . 6 Item No.2.3.2 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A . 1.5 sqmm | Mtr | 26.0 | 26.0 | 50.0 | False | None | None | False | None | False | 1300.0 | 0 | 3944470 | 152698 | None | Page No.5& 6 Item No.2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to GTP of GROUP -A.2.5 sqmm | Mtr | 42.0 | 42.0 | 60.0 | False | None | None | False | None | False | 2520.0 | 0 | 3944471 | 152698 | None | Item no.11.5.2 | Supply of round/square recess/surface mounted rollingtype LED Down light with W GU 10 LED Lamp Rib Fabricated from diecast aluminium with white powdercoated prewired to mains connector & has swivelling unit of aluminium die cast eye ball & LED Lamp position retained bycircular wire spring,with Life of 25000 burning hours & 70% lumen maintenance with CRIgreather than80.Power Input: 220-240V@50/60Hz & Power factorgreather than0.9 along with CE approved.2years Warranty against any manufacturing defect working understandard electrical conditionLED square or round down light 10-12W | No | 885.0 | 885.0 | 3.0 | False | None | None | False | None | False | 2655.0 | 0 | 3944472 | 152698 | None | Page No . 9 Item No.3.3.5 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall,including necessary rawl plugs,Machine/NF screws etc.,complete.8Way | Each | 219.0 | 219.0 | 3.0 | False | None | None | False | None | False | 657.0 | 0 | 3944473 | 152698 | None | Page No . 9 Item No.3.3.3 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall,including necessary rawl plugs,Machine/NF screws etc.,complete.-4-5 way | Each | 137.0 | 137.0 | 6.0 | False | None | None | False | None | False | 822.0 | 0 | 3944474 | 152698 | None | Item No.3.5.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos . of machine screws,bolts nuts etc.,complete on the existing metal/PVC box.-8 Module | Each | 284.0 | 284.0 | 3.0 | False | None | None | False | None | False | 852.0 | 0 | 3944475 | 152698 | None | Item No . 3.5.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos . of machine screws,bolts nuts etc.,complete on the existing metal/PVC box . 4 Module | Each | 175.0 | 175.0 | 3.0 | False | None | None | False | None | False | 525.0 | 0 | 3944476 | 152698 | None | Item No . 3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6Amps one way Switch | Each | 102.0 | 102.0 | 18.0 | False | None | None | False | None | False | 1836.0 | 0 | 3944477 | 152698 | None | Item No . 3.6.3 | Spplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6Amps 3way socket | Each | 171.0 | 171.0 | 8.0 | False | None | None | False | None | False | 1368.0 | 0 | 3944478 | 152698 | None | Item No . 3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-32Amps DP switch ( | Each | 326.0 | 326.0 | 2.0 | False | None | None | False | None | False | 652.0 | 0 | 3944479 | 152698 | None | Item No.5.7.2 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts,bolts and washers . -32A | Each | 241.0 | 241.0 | 2.0 | False | None | None | False | None | False | 482.0 | 0 | 3944480 | 152698 | None | Item no 5.18.4 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C Type curve,indicator ON/OFF,energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.-16 Amps DP
| Each | 739.0 | 739.0 | 1.0 | False | None | None | False | None | False | 739.0 | 0 | 3944481 | 152698 | None | 6.2 | Supplying fixing and wiring earth electrode for grounding of lifts,transformers,DG sets etc.using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover.The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber.The connection from the electrode is to be established through GI strip using GI bolts and nuts.
| Each | 4256.0 | 4256.0 | 1.0 | False | None | None | False | None | False | 4256.0 | 0 | 3944482 | 152698 | None | 6.3 | Supplying capacitor type ceiling fan complete with down rod blades,shackle,canopies etc,for operation on 230 V,50 cycles.Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48 inch Sweep (1200 mm) Regular model
| Each | 2984.0 | 2984.0 | 1.0 | False | None | None | False | None | False | 2984.0 | 0 | 3944483 | 152698 | None | Item No 11.3.2 | Supplying of.feet -PVC Batten with integrated LED tube.W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greather than 80.Power Input: 220-240V@ 50/60Hz & Power factorgreather than0.9 along with CE approved.2 years Warranty against any manufacturing defect working under standard electrical condition-LED light fitting 1 x 4feet -20/22 W | Each | 690.0 | 690.0 | 1.0 | False | None | None | False | None | False | 690.0 | 0 | 3944484 | 152698 | None | 5.6.4 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws 12"X12"X2"
| Each | 181.0 | 181.0 | 1.0 | False | None | None | False | None | False | 181.0 | 0 | 3944485 | 152698 | None | 11.11.3 | Supplying & fixing of retrofit type-LED bulb.W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K,CRI greather than 70%.efficacy greather than 80 lumen per W,life greather than 25000burning hours and Compliance to IS 10322/IEC 60598,LM 79 & LM 80.The LED are driven by HF electronic driver integrated in the system,with PF greather than 0.95,power loss should less than 5% of lamp Wage.,short circuit & open circuit protection to be integratedin the circuit,THD less than 20%,Life as per LM 79.Theoperating input voltage should be between 130 to 275 V.BISApproved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.-7W,6500K
| Each | 149.0 | 149.0 | 3.0 | False | None | None | False | None | False | 447.0 | 0 | 3944486 | 152698 | None | ESCOMs SR Sl no.198 I.No 32.02 | Supplying of 1.1 KV LT UG cable XLPE or Heat resistant PVC insulated,PVC extruded Inner sheath armoured UG LT cable as per IS-1554 (Part-1) or IS-7098 Part-1,Armouring strip thickness in average +5% and resistivity 14 Ohms/Kms (Max) as per IS-3975 -4 core 35 sqmm.2 core 10 sqmm.
| Mtr | 79.23 | 79.23 | 50.0 | False | None | None | False | None | False | 3961.5 | 0 | 3944487 | 152698 | None | ESCOMs SR Sl no.198 I.No 32.02 | Labour charges for laying of 1.1 KV class UG cable in existing trench GI pipe/stoneware pipe/on wall/on pole as required.In existing trench/duct.On wall/Structure .2 core 10 sqmm.
| Mtr | 79.23 | 79.23 | 15.5 | False | None | None | False | None | False | 1228.065 | 0 |
|
|
---|