tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1725627685000 | 0 | None | None | Other Works | Construction of compound wall around the building of Civil Workers Housing in Ward No.18 and Undertaking other development works | 1234734.65 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3937959 | 152209 | None | PWD SR-2023-24-Vol.1-Page No.8-Item No.1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m. | Cum | 105.06 | 105.06 | 68.624 | False | None | None | False | None | False | 7209.63744 | 0 | 3937960 | 152209 | None | PWD SR-2023-24-Vol.2-Page No.9- Item No.5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6580.67 | 6580.67 | 15.957 | False | None | None | False | None | False | 105007.75119 | 0 | 3937961 | 152209 | None | PWD SR-2023-24-Vol.1-Page No.15- Item No.2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates. | Cum | 6353.74 | 6353.74 | 7.373 | False | None | None | False | None | False | 46846.12502 | 0 | 3937962 | 152209 | None | PWD SR-2023-24-Vol.1-Page No.15- Item No.2.2.3 | Providing and laying in position Reinforced cement concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 6721.87 | 6721.87 | 9.234 | False | None | None | False | None | False | 62069.74758 | 0 | 3937963 | 152209 | None | PWD SR-2023-24-Vol.1-Page No.15- Item No.2.2.3 | Providing and laying in position Reinforced cement concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 11094.34 | 11094.34 | 1.368 | False | None | None | False | None | False | 15177.05712 | 0 | 3937964 | 152209 | None | PWD SR-2023-24-Vol.1-Page No.15- Item No.2.2.3 | Providing and laying in position Reinforced cement concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 10441.73 | 10441.73 | 6.36 | False | None | None | False | None | False | 66409.4028 | 0 | 3937965 | 152209 | None | PWD SR-2023-24-Vol.1-Page No.16- Item No.2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators.The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 11982.1 | 11982.1 | 3.876 | False | None | None | False | None | False | 46442.6196 | 0 | 3937966 | 152209 | None | PWD SR-2023-24-Vol.1-Page No.18-Item No.2.11 | Supplying, fitting and placing TMT FE 550/550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire/soft annealed steel wire and other ancilary operations complete as per drawing and technical specification | Tonne | 92140.71 | 92140.71 | 1.836 | False | None | None | False | None | False | 169170.34356 | 0 | 3937967 | 152209 | None | PWD SR-2023-24-Vol.1-Page No.7-Item No.1.9 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc.in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 273.98 | 273.98 | 34.693 | False | None | None | False | None | False | 9505.18814 | 0 | 3937968 | 152209 | None | PWD SR-2023-24-Vol.1-Page No.15 -Item No.2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.(The cost of ste el reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 10885.97 | 10885.97 | 0.925 | False | None | None | False | None | False | 10069.52225 | 0 | 3937969 | 152209 | None | PWD SR-2023-24-Vol.2-Page No.17- Item No.6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part-I)-2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Cum | 1349.3 | 1349.3 | 138.75 | False | None | None | False | None | False | 187215.375 | 0 | 3937970 | 152209 | None | PWD SR-2023-24-Vol.2-Page No.42- Item No.8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 376.98 | 376.98 | 404.58 | False | None | None | False | None | False | 152518.5684 | 0 | 3937971 | 152209 | None | PWD SR-2023-24-Vol.2-Page No.45- Item No.8.27 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 54.59 | 54.59 | 533.88 | False | None | None | False | None | False | 29144.5092 | 0 | 3937972 | 152209 | None | PWD SR-2023-24-Vol.2-Page No.14- Item No.6.8 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8287.76 | 8287.76 | 14.49 | False | None | None | False | None | False | 120089.6424 | 0 | 3937973 | 152209 | None | PWD SR-2023-24-Vol.1-Page No.15- Item No.2.2.1 | Providing and laying in position Cement Concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6540.37 | 6540.37 | 0.805 | False | None | None | False | None | False | 5264.99785 | 0 | 3937974 | 152209 | None | PWD SR-2023-24-Vol.2-Page No.42- Item No.8.7 | Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 380.64 | 380.64 | 163.1 | False | None | None | False | None | False | 62082.384 | 0 | 3937975 | 152209 | None | PWD SR-2023-24-Vol.2-Page No.45-Item No.8.27 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 55.12 | 55.12 | 163.1 | False | None | None | False | None | False | 8990.072 | 0 | 3937976 | 152209 | None | PWD SR-2023-24-Vol.2-Page No.45- Item No.8.28 | Finishing walls with water proofing cement paint of required shade :New work (Two coats applied @ 4.84 kg/10 m²) to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 92.56 | 92.56 | 163.1 | False | None | None | False | None | False | 15096.536 | 0 | 3937977 | 152209 | None | PWD SR-2023-24-Vol.2-Page No.84- Item No.11.25.2 | Providing and fixing Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc.as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 140.08 | 140.08 | 400.0 | False | None | None | False | None | False | 56032.0 | 0 | 3937978 | 152209 | None | PWD SR-2023-24-Vol.1-Page No.16-Item No.2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators.The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 11838.39 | 11838.39 | 3.0 | False | None | None | False | None | False | 35515.17 | 0 | 3937979 | 152209 | None | PWD SR-2023-24-Vol.1-Page No.18-Item No.2.11 | Supplying, fitting and placing TMT FE 550/550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire/soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 92140.71 | 92140.71 | 0.27 | False | None | None | False | None | False | 24877.9917 | 0 |
| 1725627685000 | 0 | None | None | Other Works | Construction of Anganwadi in Kambaragatti of Ward No. 17 where P caste people live and Ward No where caste people live Construction of rain water drain in Lamanitande 15 and Construction of drain near Ambedkar Oni Lords house in Ward No.8 and near fish market. | 2964693.25 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3937980 | 152210 | None | PWD SR-2023-24-Vol.1-Page No.8-Item No.1.14.1 | Mechanical Means Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m,as per drawing and technical specifications,including setting out,shoring,strutting,barricading,caution lights,including dressing of excavated surfaces,disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour,tools,usage of machinery & other appurtenaces required to complete the work. | Cum | 105.06 | 105.06 | 195.04 | False | None | None | False | None | False | 20490.9024 | 0 | 3937981 | 152210 | None | PWD SR-2023-24-Vol.1-Page No.15-Item No.2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed,laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators,including all lead & lifts,cost of all materials of quality,labour,Usage charges of machineries,curing,and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork shall be paid separately) | Cum | 6168.67 | 6168.67 | 18.02 | False | None | None | False | None | False | 111159.4334 | 0 | 3937982 | 152210 | None | PWD SR-2023-24-Vol.1-Page No.15-Item No.2.2.3 | Providing and laying in position Reinforced cement concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers,well compacted using needle vibrators,including all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes,labour,Usage charges of machinery,curing and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6721.86 | 6721.86 | 37.89 | False | None | None | False | None | False | 254691.2754 | 0 | 3937983 | 152210 | None | PWD SR-2023-24-Vol.1-Page No.15-Item No.2.2.3 | Providing and laying in position Reinforced cement concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers,well compacted using needle vibrators,including all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes,labour,Usage charges of machinery,curing and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 8810.2 | 8810.2 | 26.23 | False | None | None | False | None | False | 231091.546 | 0 | 3937984 | 152210 | None | PWD SR-2023-24-Vol.1-Page No.18-Item No.2.11 | Supplying,fitting and placing TMT FE 550/550D Steel Reinforcement including cost of all materials,machinery,labour,cleaning,straightening,cutting,bending,hooking,laping/welding joints,tying with binding wire/soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 81381.33 | 81381.33 | 4.4884 | False | None | None | False | None | False | 365271.961572 | 0 | 3937985 | 152210 | None | PWD SR-2023-24-Vol.3-Page No.17-Item No.3.1 | Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of work | Cum | 87.55 | 87.55 | 107.86 | False | None | None | False | None | False | 9443.143 | 0 | 3937986 | 152210 | None | PWD SR-2023-24-Vol.1-Page No.7-Item No.1.9 | Filling available excavated earth (excluding rock) in trenches,plinth,sides of foundations and other similar works etc.in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering,lead up to 50 m and lift upto 1.5 m. | Cum | 273.98 | 273.98 | 87.18 | False | None | None | False | None | False | 23885.5764 | 0 | 3937987 | 152210 | None | PWD SR-2023-24-Vol.2-Page No.190-Item No.19.30 | Dismantling tiled roofing with battens,boarding etc.complete including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. | Sqm | 147.29 | 147.29 | 73.7 | False | None | None | False | None | False | 10855.273 | 0 | 3937988 | 152210 | None | PWD SR-2023-24-Vol.2-Page No.188-Item No.19.14.1 | Dismantling wood work in frames,trusses,purlins and rafters upto 10 metres span and 5 metres height including stacking to the appropriate disposal area as per direction of Engineer-in-charge.Of sectional area 40 square centimeters and above | Cum | 2996.27 | 2996.27 | 1.88 | False | None | None | False | None | False | 5632.9876 | 0 | 3937989 | 152210 | None | PWD SR-2023-24-Vol.2-Page No.187-Item No.19.7.3 | Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge".In cement mortar | Cum | 1059.87 | 1059.87 | 22.69 | False | None | None | False | None | False | 24048.4503 | 0 | 3937990 | 152210 | None | PWD SR-2023-24-Vol.2-Page No.187-Item No.19.2.1 | Demolishing cement concrete manually/by mechanical means including disposal of material to the appropriate disposal area as per direction of Engineer-in-charge. | Cum | 1712.89 | 1712.89 | 10.72 | False | None | None | False | None | False | 18362.1808 | 0 | 3937991 | 152210 | None | PWD SR-2023-24-Vol.2-Page No.188-Item No.19.12.1 | Dismantling doors,windows and clerestory windows (steel or wood) shutter including chowkhats,architrave,holdfasts etc.complete and stacking to the appropriate disposal area as per direction of Engineer in charge.Of area 3 m² and below | Sqm | 266.97 | 266.97 | 7.92 | False | None | None | False | None | False | 2114.4024 | 0 | 3937992 | 152210 | None | PWD SR-2023-24-Vol.2-Page No.188-Item No.19.13.1 | Taking out doors,windows and clerestory window shutters (steel or wood) including stacking to the appropriate disposal area as per direction of Engineer-in-charge.Of area 3 m² and below | Sqm | 96.82 | 96.82 | 7.92 | False | None | None | False | None | False | 766.8144 | 0 | 3937993 | 152210 | None | PWD SR-2023-24-Vol.1-Page No.8-Item No.1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications,including setting out,shoring,strutting,barricading,caution lights,removal of stumps and other deleterious matter including dressing of excavated surfaces,disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour,tools,usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depth | Cum | 97.85 | 97.85 | 14.55 | False | None | None | False | None | False | 1423.7175 | 0 | 3937994 | 152210 | None | PWD SR-2023-24-Vol.1-Page No.8-Item No.1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m,as per drawing and technical specifications,including setting out,shoring,strutting,barricading,caution lights,including dressing of excavated surfaces,disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour,tools,usage of machinery & other appurtenaces required to complete the work.In all kinds of soils Depth upto 3 m | Cum | 105.06 | 105.06 | 87.38 | False | None | None | False | None | False | 9180.1428 | 0 | 3937995 | 152210 | None | PWD SR-2023-24-Vol.1-Page No.15-Item No.2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed,laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators,including all lead & lifts,cost of all materials of quality,labour,Usage charges of machineries,curing,and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork shall be paid separately).Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6168.67 | 6168.67 | 17.0918 | False | None | None | False | None | False | 105433.673906 | 0 | 3937996 | 152210 | None | PWD SR-2023-24-Vol.1-Page No.15-Item No.2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed,laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators,including all lead & lifts,cost of all materials of quality,labour,Usage charges of machineries,curing,and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork shall be paid separately).Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6403.51 | 6403.51 | 1.07 | False | None | None | False | None | False | 6851.7557 | 0 | 3937997 | 152210 | None | PWD SR-2023-24-Vol.1-Page No.15-Item No.2.2.3 | Providing and laying in position Reinforced cement concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers,well compacted using needle vibrators,including all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes,labour,Usage charges of machinery,curing and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7048.16 | 7048.16 | 10.93 | False | None | None | False | None | False | 77036.3888 | 0 | 3937998 | 152210 | None | PWD SR-2023-24-Vol.2-Page No.9-Item No.5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6580.67 | 6580.67 | 11.13 | False | None | None | False | None | False | 73242.8571 | 0 | 3937999 | 152210 | None | PWD SR-2023-24-Vol.1-Page No.16-Item No.2.4.3 | Providing and laying in position Reinforced cement concrete for all Sub structures of building,Irrigation works,Sub structure works of bridges,Drain works & other parallel works from 0.50m to 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers,laid in layers,well compacted using needle vibrators,providing weep holes wherever necesary,including all lead & lifts,cost of all materials of quality,confirming to the requirements of relevant IS codes,labour,Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11094.33 | 11094.33 | 1.3041 | False | None | None | False | None | False | 14468.115753 | 0 | 3938000 | 152210 | None | PWD SR-2023-24-Vol.1-Page No.16-Item No.2.3.2 | Providing and laying in Reinforced cement concrete for all Basement & surface level works,return walls,retaining walls,sunken floors etc.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers,laid in layers,well compacted using needle vibrators,providing weep holes wherever necesary,including all lead & lifts,cost of all materials of quality,labour,Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10011.6 | 10011.6 | 5.03 | False | None | None | False | None | False | 50358.348 | 0 | 3938001 | 152210 | None | PWD SR-2023-24-Vol.1-Page No.16-Item No.2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building,Road works,Water works,Irrigation works & super structure works of bridges upto 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers,well compacted using needle vibrators.The cost includes all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes,labour,Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement,dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11982.09 | 11982.09 | 2.93 | False | None | None | False | None | False | 35107.5237 | 0 | 3938002 | 152210 | None | PWD SR-2023-24-Vol.1-Page No.16-Item No.2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building,Road works,Water works,Irrigation works & super structure works of bridges upto 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers,well compacted using needle vibrators.The cost includes all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes,labour,Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement,dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11277.26 | 11277.26 | 7.5192 | False | None | None | False | None | False | 84795.973392 | 0 | 3938003 | 152210 | None | PWD SR-2023-24-Vol.1-Page No.16-Item No.2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building,Road works,Water works,Irrigation works & super structure works of bridges upto 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers,well compacted using needle vibrators.The cost includes all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes,labour,Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement,dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10572.43 | 10572.43 | 11.61 | False | None | None | False | None | False | 122745.9123 | 0 | 3938004 | 152210 | None | PWD SR-2023-24-Vol.1-Page No.16-Item No.2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building,Road works,Water works,Irrigation works & super structure works of bridges upto 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers,well compacted using needle vibrators.The cost includes all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes,labour,Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement,dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10220.02 | 10220.02 | 0.86 | False | None | None | False | None | False | 8789.2172 | 0 | 3938005 | 152210 | None | PWD SR-2023-24-Vol.1-Page No.18-Item No.2.11 | Supplying,fitting and placing TMT FE 550/550D Steel Reinforcement including cost of all materials,machinery,labour,cleaning,straightening,cutting,bending,hooking,laping/welding joints,tying with binding wire/soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 92140.71 | 92140.71 | 4.0183 | False | None | None | False | None | False | 370249.014993 | 0 | 3938006 | 152210 | None | PWD SR-2023-24-Vol.1-Page No.7-Item No.1.9 | Filling available excavated earth (excluding rock) in trenches,plinth,sides of foundations and other similar works etc.in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering,lead up to 50 m and lift upto 1.5 m. | Cum | 273.98 | 273.98 | 46.9241 | False | None | None | False | None | False | 12856.264918 | 0 | 3938007 | 152210 | None | PWD SR-2023-24-Vol.1-Page No.7-Item No.1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead,transportation to site,spreading,grading to required slope and compacting to meet the requirement complete as per specifications,including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 488.22 | 488.22 | 19.71 | False | None | None | False | None | False | 9622.8162 | 0 | 3938008 | 152210 | None | PWD SR-2023-24-Vol.2-Page No.17-Item No.6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part-I)-2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials,labour,scaffolding and curing,usage charges of machinery etc complete as per specifications. | Sqm | 1349.3 | 1349.3 | 95.19 | False | None | None | False | None | False | 128439.867 | 0 | 3938009 | 152210 | None | PWD SR-2023-24-Vol.2-Page No.17-Item No.6.33 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part-I)-2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials,labour,scaffolding and curing,usage charges of machinery etc complete as per specifications. | Sqm | 1267.93 | 1267.93 | 82.92 | False | None | None | False | None | False | 105136.7556 | 0 | 3938010 | 152210 | None | PWD SR-2023-24-Vol.2-Page No.42-Item No.8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering,providing and removing scaffolding,including cost of materials,labour,curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 382.13 | 382.13 | 132.58 | False | None | None | False | None | False | 50662.7954 | 0 | 3938011 | 152210 | None | PWD SR-2023-24-Vol.2-Page No.41-Item No.8.2.1 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering,providing and removing scaffolding,including cost of materials,labour,curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 303.85 | 303.85 | 155.6366 | False | None | None | False | None | False | 47290.18091 | 0 | 3938012 | 152210 | None | PWD SR-2023-24-Vol.2-Page No.71-Item No.10.14 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer),of approved make,in all colours,shades except burgundy,bottle green,black of any size as approved by Engineer-in-Charge,in skirting,risers of steps and dados,over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2,including pointing in white cement mixed with pigment of matching shade complete | Sqm | 1139.18 | 1139.18 | 7.11 | False | None | None | False | None | False | 8099.5698 | 0 | 3938013 | 152210 | None | PWD SR-2023-24-Vol.2-Page No.59-Item No.9.7.1 | Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457,complete as per the direction of Engineer-in-Charge.In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tile | Sqm | 1283.38 | 1283.38 | 2.25 | False | None | None | False | None | False | 2887.605 | 0 | 3938014 | 152210 | None | PWD SR-2023-24-Vol.2-Page No.46-Item No.8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade,after thoroughly brooming the surface to remove all dirt,dust,mortar drops and foreign matter including preparing the surface even and sand paper smooth,cost of materials,labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 179.22 | 179.22 | 132.58 | False | None | None | False | None | False | 23760.9876 | 0 | 3938015 | 152210 | None | PWD SR-2023-24-Vol.2-Page No.45-Item No.8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt,dust,mortar drops and foreign matter including preparing the surface even and sand paper smooth,cost of materials,labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 141.11 | 141.11 | 155.6366 | False | None | None | False | None | False | 21961.880626 | 0 | 3938016 | 152210 | None | PWD SR-2023-24-Vol.2-Page No.86-Item No.11.34A | Providing and fixing M.S.grills of required pattern in frames of windows etc.with M.S.flats,square or round bars etc.including priming coat with approved steel primer all complete.Fixed to steel windows by welding | Kg | 173.04 | 173.04 | 188.32 | False | None | None | False | None | False | 32586.8928 | 0 | 3938017 | 152210 | None | PWD SR-2023-24-Vol.2-Page No.108-Item No.12.84 | Providing & fixing of louvered ventilator made out of multi chambered PVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets-grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame.The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness.Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass.Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) | Sqm | 5173.69 | 5173.69 | 0.78 | False | None | None | False | None | False | 4035.4782 | 0 | 3938018 | 152210 | None | PWD SR-2023-24-Vol.2-Page No.104-Item No.12.54 | Providing fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm,made out of extruded 5mm rigid PVC foam sheet metered cut at corners jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube,the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge.The door frame to be fixed to the wall using M.S.Screws of 65/80mm size complete as per manufacturers specification direction of Engineer-in-charge. | Mtr | 327.54 | 327.54 | 3.78 | False | None | None | False | None | False | 1238.1012 | 0 | 3938019 | 152210 | None | PWD SR-2023-24-Vol.2-Page No.104-Item No.12.55.2 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S.tube of 19x19mm,19 gauge for stiles and 15x15mm for top & bottom rails,covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail,lock rail & bottom rail on either side & 5mm thick,20mm wide cross PVC sheet as gap insert for top rail & bottom rail,Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S.frame,Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc.,Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hingese.-do-with one side prelam | Sqm | 2101.2 | 2101.2 | 3.78 | False | None | None | False | None | False | 7942.536 | 0 | 3938020 | 152210 | None | PWD SR-2023-24-Vol.2-Page No.108-Item No.12.84 | Providing & fixing of 2-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free,gaskets-grey color having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame.The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement.Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm.Windows shall be provided with 5mm plain float glass,standard hardware& single point locking system with Crescent Locks.Wall thickness of frame & sash shall be of 2 mm.Maximum possible size-1219mm x 1219mm.(The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made)
| Sqm | 5173.69 | 5173.69 | 7.78 | False | None | None | False | None | False | 40251.3082 | 0 | 3938021 | 152210 | None | PWD SR-2023-24-Vol.2-Page-111-Item No.12.93.1 | Providing & fixing Factory made single extruded Wood Polymer Composite (WPC) solid door/window,clerestory windows & frames/chowkhat of frame Size 62 x 100mm
| Rmtr | 786.24 | 786.24 | 3.9 | False | None | None | False | None | False | 3066.336 | 0 | 3938022 | 152210 | None | PWD SR-2023-24-Vol.2-Page-112-Item No.12.94.1 | Providing and fixing factory made Green certified,Anti Termite,UV resistant,high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade),calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge),minimum compressive strength of 50 N/mm2,modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof,water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials,transportation,labour and fixing charges.(Cost of Fixtures to be paid separately) 30 mm thickness | Sqm | 3589.55 | 3589.55 | 4.62 | False | None | None | False | None | False | 16583.721 | 0 | 3938023 | 152210 | None | PWD SR-2021-22-Vol.2-Page No.100-Item No.9.12.2 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622,of approved make,in all colours and shades,laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand),jointing with grey cement slurry @ 3.3 kg/m2 including grouting the joints with white cement and matching pigments etc.,complete.Size of Tile 600x600 mm | Sqm | 1179.35 | 1179.35 | 43.8656 | False | None | None | False | None | False | 51732.89536 | 0 | 3938024 | 152210 | None | PWD SR-2023-24-Vol.2-Page No.60-Item No.9.12.2 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom,cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412.The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane.The finished cost to include surface preparation,making coving at Junction,Bore Packing,treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 841.51 | 841.51 | 60.246 | False | None | None | False | None | False | 50697.61146 | 0 | 3938025 | 152210 | None | PWD SR-2023-24-Vol.2-Page 149-Item No.15.1 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid,10 litre low level white vitreous china flushing cistern & C.P.flush bend with fittings & C.I.brackets,40 mm flush bend,overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete,including painting of fittings and brackets,cutting and making good the walls and floors wherever required W.C.pan with ISI marked white solid plastic seat and lid | No | 6156.31 | 6156.31 | 5.0 | False | None | None | False | None | False | 30781.55 | 0 | 3938026 | 152210 | None | PWD SR-2023-24-Vol.2-Page No.131-Item No.14.3.1 | Providing and fixing wash basin with C.I.brackets,15 mm C.P.brass pillar taps,32 mm C.P.brass waste of standard pattern,including painting of fittings and brackets,cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P.brass pillar tap | No | 2637.83 | 2637.83 | 2.0 | False | None | None | False | None | False | 5275.66 | 0 | 3938027 | 152210 | None | PWD SR-2023-24-Vol.2 Page-123-Item No.13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS 12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank. | Ltr | 9.27 | 9.27 | 1000.0 | False | None | None | False | None | False | 9270.0 | 0 | 3938028 | 152210 | None | PWD SR-2023-24-Vol.2-Page-122 Item No.13.32.2 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778,having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr 21 spacing.This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete.(Concealed work including cutting chases and good the walls etc.).20mm nominal dia pipes | Rmtr | 390.37 | 390.37 | 25.0 | False | None | None | False | None | False | 9759.25 | 0 | 3938029 | 152210 | None | PWD SR-2023-24-Vol.2-Page-122 Item No.13.32.3 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778,having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr 21 spacing.This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete.(Concealed work including cutting chases and good the walls etc.).25mm nominal dia pipes | Rmtr | 491.31 | 491.31 | 30.0 | False | None | None | False | None | False | 14739.3 | 0 | 3938030 | 152210 | None | PWD SR-2023-24-Vol.2-Page-122 Item No.13.32.4 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778,having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr 21 spacing.This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete.(Concealed work including cutting chases and good the walls etc.).32mm nominal dia pipes | Rmtr | 573.71 | 573.71 | 30.0 | False | None | None | False | None | False | 17211.3 | 0 | 3938031 | 152210 | None | PWD SR-2023-24-Vol.2-Page-125 Item No.13.48 | Providing and fixing on wall face unplasticised rigid PVC Rain pipes conforming to IS:13592 Type A,including jointing with seal ring conforming to IS:5382,leaving 10 mm gap for thermal expansion,(i) Single soaked pipes 100mm dia | Rmtr | 299.73 | 299.73 | 12.0 | False | None | None | False | None | False | 3596.76 | 0 | 3938032 | 152210 | None | PWD SR-2023-24-Vol.2-Page No.136-Item No.14.29 | Providing and fixing 100 mm sand cast Iron grating for gully trap | No | 48.41 | 48.41 | 3.0 | False | None | None | False | None | False | 145.23 | 0 | 3938033 | 152210 | None | S.R.Electrical 2023-24 Chapter-1,Item No.1.2.1 | Concealed Conduit System Supplying Heavy Gauge PVC Conduit pipe 19/20 mm dia 2mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes adhesive paste etc.,and running before concreting the slab.The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipes ends should be covered using PVC end enclosures.run with 18SWG GI fish wire wherever necessary.-19/20 mm dia 2 mm thick | Per Mtr | 66.0 | 66.0 | 180.0 | False | None | None | False | None | False | 11880.0 | 0 | 3938034 | 152210 | None | S.R.Electrical 2023-24 Chapter-1.Item No.1.2.2 | Concealed Conduit System Supplying Heavy Gauge PVC Conduit pipe 25 mm dia 2mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes adhesive paste etc.,and running before concreting the slab.The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipes ends should be covered using PVC end enclosures.run with 18SWG GI fish wire wherever necessary-25 mm dia 2 mm thick | Per Mtr | 78.0 | 78.0 | 1053.0 | False | None | None | False | None | False | 82134.0 | 0 | 3938035 | 152210 | None | S.R.Electrical 2023-24 Chapter-1,Item No.1.3.1 | Concealed conduit System,Supplying Heavy Gauge PVC Conduit Pipe 19/20mm dia 2mm thick with suitable size bends,metal/PVE junction boxes adhesive paste etc.,by groove cutting in the wall & fixing by using U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run through out the conduit wherever necessary-19/20 mm dia 2 mm thick | Per Mtr | 68.0 | 68.0 | 95.0 | False | None | None | False | None | False | 6460.0 | 0 | 3938036 | 152210 | None | S.R.Electrical 2023-24 Chapter-1,Item No.1.3.2 | Concealed conduit System,Supplying Heavy Gauge PVC Conduit Pipe 25mm dia 2mm thick with suitable size bends,metal/PVE junction boxes adhesive paste etc.,by groove cutting in the wall & fixing by using U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run through out the conduit wherever necessary-25 mm dia 2 mm thick | Per Mtr | 79.0 | 79.0 | 68.0 | False | None | None | False | None | False | 5372.0 | 0 | 3938037 | 152210 | None | S.R.Electrical 2023-24 Chapter-1,Item No.1.2.3 | Concealed conduit System,Supplying Heavy Gauge PVC Conduit Pipe 32mm dia 2.5 mm thick with Confirming to IS 2509 with suitable size bends,metal/PVC junction boxes adhesive paste etc.,and running before concreting the slab.The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosure.Run with 18SWG GI fish wire wherever necessary-25 mm dia 2.5 mm thick | Per Mtr | 103.0 | 103.0 | 55.0 | False | None | None | False | None | False | 5665.0 | 0 | 3938038 | 152210 | None | S.R.Electrical 2023-24 Chapter-3,Item No.3.3.1 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall,including necessary rawl plugs,Machine/NF screws etc.,complete.-1-2 Way | Each | 103.0 | 103.0 | 9.0 | False | None | None | False | None | False | 927.0 | 0 | 3938039 | 152210 | None | S.R.Electrical 2023-24 Chapter-3,Item No.3.3.3 | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall,including necessary rawl plugs,Machine/NF screws etc.,complete.-4-5 Way | Each | 137.0 | 137.0 | 8.0 | False | None | None | False | None | False | 1096.0 | 0 | 3938040 | 152210 | None | S.R.Electrical 2023-24 Chapter-3,Item No.3.3.5. | Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall,including necessary rawl plugs,Machine/NF screws etc.,complete.-8 Way | Each | 219.0 | 219.0 | 6.0 | False | None | None | False | None | False | 1314.0 | 0 | 3938041 | 152210 | None | S.R.Electrical 2023-24 Chapter-3,Item No.3.3.1, | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws,bolts nuts etc.,complete on the existing metal/PVC box.1 to 2 Module | Each | 137.0 | 137.0 | 2.0 | False | None | None | False | None | False | 274.0 | 0 | 3938042 | 152210 | None | S.R.Electrical 2023-24 Chapter-3,Item No.3.3.3 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws,bolts nuts etc.,complete on the existing metal/PVC box.4 Module | Each | 175.0 | 175.0 | 1.0 | False | None | None | False | None | False | 175.0 | 0 | 3938043 | 152210 | None | S.R.Electrical 2023-24 Chapter-3,Item No.3.3.5 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos.of machine screws,bolts nuts etc.,complete on the existing metal/PVC box.8 Module | Each | 284.0 | 284.0 | 2.0 | False | None | None | False | None | False | 568.0 | 0 | 3938044 | 152210 | None | S.R.Electrical 2023-24 Chapter-3,Item No.3.6.1 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6A One Way Switch | Each | 102.0 | 102.0 | 26.0 | False | None | None | False | None | False | 2652.0 | 0 | 3938045 | 152210 | None | S.R.Electrical 2023-24 Chapter-3,Item No.3.6.2 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6A Two Way Switch | Each | 166.0 | 166.0 | 6.0 | False | None | None | False | None | False | 996.0 | 0 | 3938046 | 152210 | None | S.R.Electrical 2023-24 Chapter-3,Item No.3.6.3 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6A Three Way socket | Each | 171.0 | 171.0 | 6.0 | False | None | None | False | None | False | 1026.0 | 0 | 3938047 | 152210 | None | S.R.Electrical 2023-24 Chapter-3,Item No.3.6.9 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-32A DP Switch | Each | 326.0 | 326.0 | 6.0 | False | None | None | False | None | False | 1956.0 | 0 | 3938048 | 152210 | None | S.R.Electrical 2023-24 Chapter-3,Item No.3.6.10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.-6/16A Universal Socket | Each | 236.0 | 236.0 | 6.0 | False | None | None | False | None | False | 1416.0 | 0 | 3938049 | 152210 | None | Elec SR23-24 Chapter-2, Item No.2.1.1,2.1.2,2.1.3. | Point Wiring using Copper wire with switch.
Supplying and wiring adopting loop system in existing PVC conduit/casing capping using 1100V grade,COPPER conductor flexible multi strand FRLS PVC insulated to 2X1.5 Sqmm cabale confirming to the GTP with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box,the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet-Short point upto 3 Mtr from tapping point to outlet via switch. | No | 285.0 | 285.0 | 10.0 | False | None | None | False | None | False | 2850.0 | 0 | 3938050 | 152210 | None | S.R.Electrical 2023-24 Chapter-2,Item No.2.1.2 | Point Wiring using Copper wire with switch.
Supplying and wiring adopting loop system in existing PVC conduit/casing capping using 1100V grade,COPPER conductor flexible multi strand FRLS PVC insulated to 2X1.5 Sqmm cabale confirming to the GTP with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box,the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet-Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch. | No | 394.0 | 394.0 | 9.0 | False | None | None | False | None | False | 3546.0 | 0 | 3938051 | 152210 | None | S.R.Electrical 2023-24 Chapter-2,Item No.2.1.3. | Point Wiring using Copper wire with switch.
Supplying and wiring adopting loop system in existing PVC conduit/casing capping using 1100V grade,COPPER conductor flexible multi strand FRLS PVC insulated to 2X1.5 Sqmm cabale confirming to the GTP with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box,the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet-Long point above 6Mtr up to 10Mtr from tapping point to outlet via switch. | No | 570.0 | 570.0 | 7.0 | False | None | None | False | None | False | 3990.0 | 0 | 3938052 | 152210 | None | S.R.Electrical 2023-24 Chapter-3,Item No.3.1.2 | Supplying 6A flush type socket and 6Amps flush type SP switch either surface/flush mounting in existing gang box or in a 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required.as per IS 1293 and IS 3654-6 Amps 3/5 way | Each | 147.0 | 147.0 | 6.0 | False | None | None | False | None | False | 882.0 | 0 | 3938053 | 152210 | None | S.R.Electrical 2023-24 Chapter-2,Item No.2.3.1 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade,multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTP-1 mm2 | Mtr | 19.0 | 19.0 | 45.0 | False | None | None | False | None | False | 855.0 | 0 | 3938054 | 152210 | None | S.R.Electrical 2023-24 Chapter-2,Item No.2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade,multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTP-1.5 mm2 | Mtr | 26.0 | 26.0 | 45.0 | False | None | None | False | None | False | 1170.0 | 0 | 3938055 | 152210 | None | S.R.Electrical 2023-24 Chapter-2,Item No.2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade,multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTP-2.5 mm2 | Mtr | 42.0 | 42.0 | 35.0 | False | None | None | False | None | False | 1470.0 | 0 | 3938056 | 152210 | None | S.R.Electrical 2023-24 Chapter-2,Item No.2.3.5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade,multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTP-4 mm2 | Mtr | 63.0 | 63.0 | 35.0 | False | None | None | False | None | False | 2205.0 | 0 | 3938057 | 152210 | None | S.R.Electrical 2023-24 Chapter-6,Item No.6.2.2 | Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz,AC Supply complete.-15 Sweep (450 mm) | Each | 4446.0 | 4446.0 | 8.0 | False | None | None | False | None | False | 35568.0 | 0 | 3938058 | 152210 | None | S.R.Electrical 2023-24 Chapter-13,Item No.13.13 | Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets,with bolts and nuts and a 5 A,ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.-Exhaust fan | Each | 707.0 | 707.0 | 6.0 | False | None | None | False | None | False | 4242.0 | 0 | 3938059 | 152210 | None | S.R.Electrical 2023-24 Chapter-11,Item No.11.3.2 | Supplying of .4 feet-PVC Batten with integrated LED tube 20/22 W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI greather than 80.Power Input: 220-240V@ 50/60Hz & Power factor greather than 0.9 along with CE approved.2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4 feet -20/22 W | Each | 690.0 | 690.0 | 7.0 | False | None | None | False | None | False | 4830.0 | 0 | 3938060 | 152210 | None | S.R.Electrical 2023-24 Chapter-13,Item No.13.7.1 | Fixing all types and all capacities of fluorescent/false ceiling/spot light/CFL/LED fittings indoor on the wall/ceiling/rafters/girders using 23/0.0076 inch twin twisted PVC insulated wires,required Nos of round blocks and clA-On wall/ceiling/Rafter/Girders | Each | 122.0 | 122.0 | 7.0 | False | None | None | False | None | False | 854.0 | 0 | 3938061 | 152210 | None | S.R.Electrical 2023-24 Chapter-5,Item No.5.7.3 | Supplying & fixing of porcelain fuse channel with cut out on existing wooden/panel using necessary nuts,bolts and washers etc.,complete.63 Amps | Each | 401.0 | 401.0 | 1.0 | False | None | None | False | None | False | 401.0 | 0 | 3938062 | 152210 | None | S.R.Electrical 2023-24 Chapter-5,Item No.5.18.4 | Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve,indicator ON/OFF,energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898-6-32 Amps DP | Each | 739.0 | 739.0 | 4.0 | False | None | None | False | None | False | 2956.0 | 0 | 3938063 | 152210 | None | S.R.Electrical 2023-24 Chapter-5,Item No.5.18.10 | Supplying and fixing regular MCB distribution boards on wall/ood board/flush mounting using required clA,bolts,nuts etc.,with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure-16 Way SP & N | Each | 2908.0 | 2908.0 | 2.0 | False | None | None | False | None | False | 5816.0 | 0 | 3938064 | 152210 | None | S.R.Electrical 2023-24 Chapter-5,Item No.5.20.1 | Supplying,fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board.A) 63 Amps 4 pole-16-25 Amps 2 Pole | Each | 4277.0 | 4277.0 | 4.0 | False | None | None | False | None | False | 17108.0 | 0 | 3938065 | 152210 | None | S.R.Electrical 2023-24 Chapter-5,Item No.5.42.2 | Fabricating supplying and mounting MS box made out 16 SWG suitable for floor/wall mounting,fully weather proof with provision for better heat dissipation,provided with hinged front cover,equipped with tamper proof locking arrangements,with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc.,complete-16 SWG (Box 50 cm X 60 cm X 30 cm) | Sq CM | 0.43 | 0.43 | 6500.0 | False | None | None | False | None | False | 2795.0 | 0 | 3938066 | 152210 | None | ElecSR2023-24 Chapter-11, Item No.11.11.4,11.11.5 | Supplying & fixing of retrofit type-LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K,CRI greather than 70%.efficacy greather than 80 lumen per W,life greather than 25000 burning hours and Compliance to IS 10322/IEC 60598,LM 79 & LM 80.The LED are driven by HF electronic driver integrated in the system,with PF greather than 0.95,power loss should less than 5% of lamp Wage.,short circuit & open circuit protection to be integrated in the circuit,THD less than 20%,Life as per LM 79.The operating input voltage should be between 130 to 275 V.BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.-9W,6500K | Each | 154.0 | 154.0 | 5.0 | False | None | None | False | None | False | 770.0 | 0 | 3938067 | 152210 | None | S.R.Electrical 2023-24 Chapter-11,Item No.11.11.5 | Supplying & fixing of retrofit type-LED bulb W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K,CRI greather than 70%.efficacy greather than 80 lumen per W,life greather than 25000 burning hours and Compliance to IS 10322/IEC 60598,LM 79 & LM 80.The LED are driven by HF electronic driver integrated in the system,with PF greather than 0.95,power loss should less than 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit,THD less than 20%,Life as per LM79.The operating input voltage should be between 130 to 275 V.BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition-12W,6500K | Each | 269.0 | 269.0 | 5.0 | False | None | None | False | None | False | 1345.0 | 0 |
| 1725627685000 | 0 | None | None | Other Works | Construction of disabled toilet in Taluka Playground in Ward No.04. | 899112.97 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3938068 | 152211 | None | PWD SR-2023-24-Vol.1-Page No.8-Item No.1.12 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work.In all kinds of soils upto 300 mm depth | Cum | 97.85 | 97.85 | 7.1 | False | None | None | False | None | False | 694.735 | 0 | 3938069 | 152211 | None | PWD SR-2023-24-Vol.1-Page No.8-Item No.1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work.In all kinds of soils Depth upto 3 m | Cum | 105.06 | 105.06 | 31.73 | False | None | None | False | None | False | 3333.5538 | 0 | 3938070 | 152211 | None | PWD SR-2023-24-Vol.1-Page No.15-Item No.2.1.3 | Providing and laying in position plain cement concrete for levelling course for all works in foundation.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork shall be paid separately).Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6168.67 | 6168.67 | 5.07 | False | None | None | False | None | False | 31275.1569 | 0 | 3938071 | 152211 | None | PWD SR-2023-24-Vol.1-Page No.15-Item No.2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork shall be paid separately).Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6403.51 | 6403.51 | 0.74 | False | None | None | False | None | False | 4738.5974 | 0 | 3938072 | 152211 | None | PWD SR-2023-24-Vol.1-Page No.15-Item No.2.2.3 | Providing and laying in position Reinforced cement concrete for all Foundation works.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork to be paid separately)-M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 7048.17 | 7048.17 | 3.88 | False | None | None | False | None | False | 27346.8996 | 0 | 3938073 | 152211 | None | PWD SR-2023-24-Vol.2-Page No.9-Item No.5.4 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) | Cum | 6580.67 | 6580.67 | 6.16 | False | None | None | False | None | False | 40536.9272 | 0 | 3938074 | 152211 | None | PWD SR-2023-24-Vol.1-Page No.16-Item No.2.4.3 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11094.34 | 11094.34 | 0.216 | False | None | None | False | None | False | 2396.37744 | 0 | 3938075 | 152211 | None | PWD SR-2023-24-Vol.1-Page No.16-Item No.2.4.3 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9789.12 | 9789.12 | 2.12 | False | None | None | False | None | False | 20752.9344 | 0 | 3938076 | 152211 | None | PWD SR-2023-24-Vol.1-Page No.16-Item No.2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators.The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11982.1 | 11982.1 | 0.67 | False | None | None | False | None | False | 8028.007 | 0 | 3938077 | 152211 | None | PWD SR-2023-24-Vol.1-Page No.16-Item No.2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators.The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 11277.27 | 11277.27 | 2.24 | False | None | None | False | None | False | 25261.0848 | 0 | 3938078 | 152211 | None | PWD SR-2023-24-Vol.1-Page No.16-Item No.2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators.The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10572.44 | 10572.44 | 3.22 | False | None | None | False | None | False | 34043.2568 | 0 | 3938079 | 152211 | None | PWD SR-2023-24-Vol.1-Page No.16-Item No.2.5.2 | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators.The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement, dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 10220.03 | 10220.03 | 0.41 | False | None | None | False | None | False | 4190.2123 | 0 | 3938080 | 152211 | None | PWD SR-2023-24-Vol.1-Page No.18-Item No.2.11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. | Tonne | 92140.71 | 92140.71 | 1.021 | False | None | None | False | None | False | 94075.66491 | 0 | 3938081 | 152211 | None | PWD SR-2023-24-Vol.1-Page No.7-Item No.1.9 | Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations and other similar works etc.in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 273.98 | 273.98 | 16.404 | False | None | None | False | None | False | 4494.36792 | 0 | 3938082 | 152211 | None | PWD SR-2023-24-Vol.1-Page No.7-Item No.1.8 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. | Cum | 488.22 | 488.22 | 8.2 | False | None | None | False | None | False | 4003.404 | 0 | 3938083 | 152211 | None | PWD SR-2023-24-Vol.2-Page No.17-Item No.6.32 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part-I)-2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1349.3 | 1349.3 | 45.87 | False | None | None | False | None | False | 61892.391 | 0 | 3938084 | 152211 | None | PWD SR-2023-24-Vol.2-Page No.17-Item No.6.33 | Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part-I)-2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. | Sqm | 1267.93 | 1267.93 | 31.93 | False | None | None | False | None | False | 40485.0049 | 0 | 3938085 | 152211 | None | PWD SR-2023-24-Vol.2-Page No.42-Item No.8.8 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 382.13 | 382.13 | 73.02 | False | None | None | False | None | False | 27903.1326 | 0 | 3938086 | 152211 | None | PWD SR-2023-24-Vol.2-Page No.41-Item No.8.1.2 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 248.23 | 248.23 | 60.6 | False | None | None | False | None | False | 15042.738 | 0 | 3938087 | 152211 | None | PWD SR-2023-24-Vol.2-Page No.71-Item No.10.14 | Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete | Sqm | 1139.18 | 1139.18 | 54.96 | False | None | None | False | None | False | 62609.3328 | 0 | 3938088 | 152211 | None | PWD SR-2023-24-Vol.2-Page No.59-Item No.9.7.1 | Providing and fixing 10 mm thick acid and/or alkali resistant tiles of ap proved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in-Charge.In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tile | Sqm | 1283.38 | 1283.38 | 18.0 | False | None | None | False | None | False | 23100.84 | 0 | 3938089 | 152211 | None | PWD SR-2023-24-Vol.2-Page No.46-Item No.8.30 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 179.22 | 179.22 | 73.02 | False | None | None | False | None | False | 13086.6444 | 0 | 3938090 | 152211 | None | PWD SR-2023-24-Vol.2-Page No.45-Item No.8.25 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 141.11 | 141.11 | 60.6 | False | None | None | False | None | False | 8551.266 | 0 | 3938091 | 152211 | None | PWD SR-2023-24-Vol.2-Page No.85-Item No.11.34A | Providing and fixing M.S.grills of required pattern in frames of windows etc.with M.S.flats, square or round bars etc.including priming coat with approved steel primer all complete.Fixed to steel windows by welding | Kgs | 173.04 | 173.04 | 68.04 | False | None | None | False | None | False | 11773.6416 | 0 | 3938092 | 152211 | None | PWD SR-2023-24-Vol.2-Page No.108-Item No.12.84 | Providing & fixing of louvered ventilator made out of multi chambered PVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets-grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame.The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness.Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass.Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&Ps shall not be made) | Sqm | 5173.69 | 5173.69 | 3.24 | False | None | None | False | None | False | 16762.7556 | 0 | 3938093 | 152211 | None | PWD SR-2023-24-Vol.2-Page No.104-Item No.12.54 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge.The door frame to be fixed to the wall using M.S.Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge. | Sqm | 327.54 | 327.54 | 13.23 | False | None | None | False | None | False | 4333.3542 | 0 | 3938094 | 152211 | None | PWD SR-2023-24-Vol.2-Page No.104-Item No.12.55.2 | Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S.tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S.frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hingese.-do-with one side prelam | Sqm | 2101.2 | 2101.2 | 13.23 | False | None | None | False | None | False | 27798.876 | 0 | 3938095 | 152211 | None | PWD SR-2023-24-Vol.2-Page No.77-Item No.11.3 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 8524.28 | 8524.28 | 5.46 | False | None | None | False | None | False | 46542.5688 | 0 | 3938096 | 152211 | None | PWD SR-2023-24-Vol.2-Page 84-Item No.11.26.1 | Providing and fixing hand rail of approved size by welding etc.to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer.M.S.tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer in-Charge. | Kgs | 142.14 | 142.14 | 200.0 | False | None | None | False | None | False | 28428.0 | 0 | 3938097 | 152211 | None | PWD SR-2023-24-Vol.2-Page 149-Item No.15.1 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412.The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane.The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge. | Sqm | 841.51 | 841.51 | 26.25 | False | None | None | False | None | False | 22089.6375 | 0 | 3938098 | 152211 | None | PWD SR-2023-24-Vol.2-Page No.131-Item No.14.3.1 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P.flush bend with fittings & C.I.brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required W.C.pan with ISI marked white solid plastic seat and lid | No | 6156.31 | 6156.31 | 6.0 | False | None | None | False | None | False | 36937.86 | 0 | 3938099 | 152211 | None | PWD SR-2023-24-Vol.2-Page No.132-Item No.14.7.2 | Providing and fixing wash basin with C.I.brackets, 15 mm C.P.brass pillar taps, 32 mm C.P.brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P.brass pillar tap | No | 2637.83 | 2637.83 | 2.0 | False | None | None | False | None | False | 5275.66 | 0 | 3938100 | 152211 | None | PWD SR-2023-24-Vol.5-Page No.157-Item No.13.40.1 | Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments 2 HP, Size 65x50 Head 13M, Discharge 462 LPM | No | 16078.3 | 16078.3 | 1.0 | False | None | None | False | None | False | 16078.3 | 0 | 3938101 | 152211 | None | PWD SR-2023-24-Vol.2-Page-123-Item No.13.34 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. | Ltr | 9.27 | 9.27 | 1000.0 | False | None | None | False | None | False | 9270.0 | 0 | 3938102 | 152211 | None | PWD SR-2023-24-Vol.2-Page-122 Item No.13.32.1 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr 21 spacing.This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete.(Concealed work including cutting chases and good the walls etc.).15mm nominal dia pipes. | Rmtr | 318.27 | 318.27 | 15.0 | False | None | None | False | None | False | 4774.05 | 0 | 3938103 | 152211 | None | PWD SR-2023-24-Vol.2-Page-122 Item No.13.32.2 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr 21 spacing.This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete.(Concealed work including cutting chases and good the walls etc.).20mm nominal dia pipes | Rmtr | 390.37 | 390.37 | 15.0 | False | None | None | False | None | False | 5855.55 | 0 | 3938104 | 152211 | None | PWD SR-2023-24-Vol.2-Page-122 Item No.13.32.3 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr 21 spacing.This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete.(Concealed work including cutting chases and good the walls etc.).25mm nominal dia pipes | Rmtr | 491.31 | 491.31 | 15.0 | False | None | None | False | None | False | 7369.65 | 0 | 3938105 | 152211 | None | PWD SR-2023-24-Vol.2-Page-122 Item No.13.32.4 | Providing and fixing Chorinated Poly Venyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr 21 spacing.This includes jointing of pipes and fittings with one step CPVC solvent cement & the cost of cutting chases & making good the same including testing of joints complete.(Concealed work including cutting chases and good the walls etc.).32mm nominal dia pipes | Rmtr | 573.71 | 573.71 | 15.0 | False | None | None | False | None | False | 8605.65 | 0 | 3938106 | 152211 | None | PWD SR-2023-24-Vol.2-Page-125 Item No.13.48 | Providing and fixing on wall face unplasticised rigid PVC Rain pipes conforming to IS:13592 Type A, including jointing with seal ring conforming to IS:5382, leaving 10 mm gap for thermal expansion, (i) Single soaked pipes 100mm dia | Rmtr | 299.73 | 299.73 | 7.0 | False | None | None | False | None | False | 2098.11 | 0 | 3938107 | 152211 | None | PWD SR-2023-24-Vol.2-Page No.136-Item No.14.29 | Providing and fixing 100 mm sand cast Iron grating for gully trap | No | 48.41 | 48.41 | 6.0 | False | None | None | False | None | False | 290.46 | 0 | 3938108 | 152211 | None | PWD SR-2023-24-Vol.2-Page No.117-Item No.13.2.1 | Making connection of G.I.distribution branch with G.I.main of following sizes by providing and fixing tee, including cutting and threading the pipe etc.complete : 15 mm nominal bore | No | 294.58 | 294.58 | 10.0 | False | None | None | False | None | False | 2945.8 | 0 | 3938109 | 152211 | None | 1.2.1 | Concealed Conduit System Supplying Heavy Gauge PVC Conduit pipe 19/20 mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab.The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipes ends should be covered using PVC end enclosures.run with 18SWG GI fish wire wherever necessary. | Per Mtr | 66.0 | 66.0 | 25.0 | False | None | None | False | None | False | 1650.0 | 0 | 3938110 | 152211 | None | 1.2.2 | Concealed Conduit System Supplying Heavy Gauge PVC Conduit pipe 25 mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab.The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipes ends should be covered using PVC end enclosures.run with 18SWG GI fish wire wherever necessary. | Per Mtr | 78.0 | 78.0 | 25.0 | False | None | None | False | None | False | 1950.0 | 0 | 3938111 | 152211 | None | 2.1.3 | Point Wiring using Copper wire with switch.Supplying and wiring adopting loop system in existing PVC conduit / casing capping using 1100V grade, COPPER conductor flexible multi strand FRLS PVC insulated to 2X1.5 Sqmm cabale confirming to the GTP with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete for each outlet.using class A materials long point above 6 Mtr up to 10 Mtr from tapping point to outlet via switch. | No | 570.0 | 570.0 | 25.0 | False | None | None | False | None | False | 14250.0 | 0 | 3938112 | 152211 | None | 2.3.1 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTP of Group A material.1.0 Sqmm | Mtr | 19.0 | 19.0 | 25.0 | False | None | None | False | None | False | 475.0 | 0 | 3938113 | 152211 | None | 2.3.3 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTP of Group A material.2.5 Sqmm | Mtr | 42.0 | 42.0 | 25.0 | False | None | None | False | None | False | 1050.0 | 0 | 3938114 | 152211 | None | 2.3.4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTP of Group A material.4.0 Sqmm | Mtr | 63.0 | 63.0 | 25.0 | False | None | None | False | None | False | 1575.0 | 0 | 3938115 | 152211 | None | 5.19.14 | 12 Way TP&N | Each | 8735.0 | 8735.0 | 1.0 | False | None | None | False | None | False | 8735.0 | 0 | 3938116 | 152211 | None | 5.20.1 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board.A) 63 Amps 4 pole-16-25 Amps 2 Pole
| Each | 4277.0 | 4277.0 | 1.0 | False | None | None | False | None | False | 4277.0 | 0 | 3938117 | 152211 | None | 5.20.4 | 32-40 Amps 4 Pole
| Each | 4559.0 | 4559.0 | 2.0 | False | None | None | False | None | False | 9118.0 | 0 | 3938118 | 152211 | None | 5.20.8 | 63 Amps 4 Pole
| Each | 5147.0 | 5147.0 | 2.0 | False | None | None | False | None | False | 10294.0 | 0 | 3938119 | 152211 | None | 3.4.4 | 6 Model Metal Boxes
| Each | 220.0 | 220.0 | 2.0 | False | None | None | False | None | False | 440.0 | 0 | 3938120 | 152211 | None | 3.4.6 | 10-12 Model Metal Boxes | Each | 319.0 | 319.0 | 2.0 | False | None | None | False | None | False | 638.0 | 0 | 3938121 | 152211 | None | 3.6.1 | 6 Amps one way Switches | Each | 102.0 | 102.0 | 8.0 | False | None | None | False | None | False | 816.0 | 0 | 3938122 | 152211 | None | 3.6.3 | 6 amps 3 way socket | Each | 171.0 | 171.0 | 5.0 | False | None | None | False | None | False | 855.0 | 0 | 3938123 | 152211 | None | 3.6.8 | 16 Amps one way Switches | Each | 180.0 | 180.0 | 3.0 | False | None | None | False | None | False | 540.0 | 0 | 3938124 | 152211 | None | 3.6.11 | 16 amps 3 way socket | Each | 180.0 | 180.0 | 3.0 | False | None | None | False | None | False | 540.0 | 0 | 3938125 | 152211 | None | 11.3.3 | LED Light Fitting 1 x 4-36/40 watts
| Each | 1269.0 | 1269.0 | 3.0 | False | None | None | False | None | False | 3807.0 | 0 | 3938126 | 152211 | None | 5.44.4 | 600 mm x 600 mm x 170 mm Out door Thermoplastic Modular Panel
| Each | 14520.0 | 14520.0 | 1.0 | False | None | None | False | None | False | 14520.0 | 0 | 3938127 | 152211 | None | 32.05 | 16 Sq mm 4 Core Aluminium Armoud Cable
| Km | 141842.0 | 141842.0 | 0.06 | False | None | None | False | None | False | 8510.52 | 0 |
| 1725627685000 | 0 | None | None | Other Works | Ward No. 13 P. Construction of rain water drain opposite the dormitory of sect students. | 1199364.41 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3938128 | 152212 | None | PWD SR-2023-24-Vol.3-Page No.78-Item No.8.54 | Providing and fixing board displaying information,such as Name of work,Tender cost,Name of Contractor,Work completion and liability period etc,having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border/messages/symbols etc.with approved colour shade paint complete,on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S.angles of size 35mmx35mmx3mm duly painted including Two M.S.angle iron posts of size 65 mm x 65 mm x 6 mm,3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 concrete block of size 60 cm x 60 cm x 75 cm including,excavation,refilling,transportation,and labour etc complete.Spec.No.As directed by Engineer in Charge & MoRTH specification 804 | No. | 9270.0 | 9270.0 | 1.0 | False | None | None | False | None | False | 9270.0 | 0 | 3938129 | 152212 | None | PWD SR-2023-24-Vol.1-Page No.8-Item No.1.14.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m,as per drawing and technical specifications,including setting out,shoring,strutting,barricading,caution lights,including dressing of excavated surfaces,disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour,tools,usage of machinery & other appurtenaces required to complete the work.In all kinds of soils Depth upto 3 m | Cum | 105.06 | 105.06 | 244.2 | False | None | None | False | None | False | 25655.652 | 0 | 3938130 | 152212 | None | PWD SR-2023-24-Vol.1-Page No.8-Item No.1.15.1 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m,as per drawing and technical specifications,including setting out,shoring,strutting,barricading,caution lights,including dressing of excavated surfaces,disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour,tools,usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 373.89 | 373.89 | 20.35 | False | None | None | False | None | False | 7608.6615 | 0 | 3938131 | 152212 | None | PWD SR-2023-24 Vol.1-Page No.15-Item No.2.1.4 | Providing and laying in position plain cement concrete for levelling course for all works in foundation.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed,laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators,including all lead & lifts,cost of all materials of quality,labour,Usage charges of machineries,curing,and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork shall be paid separately)
Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6403.51 | 6403.51 | 40.7 | False | None | None | False | None | False | 260622.857 | 0 | 3938132 | 152212 | None | PWD SR-2023-24-Vol.1-Page No.17-Item No.2.4.2 | Providing and laying in position Reinforced cement concrete for all Sub structures of building,Irrigation works,Sub structure works of bridges,Drain works & other parallel works from 0.50m to 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers,laid in layers,well compacted using needle vibrators,providing weep holes wherever necesary,including all lead & lifts,cost of all materials of quality,confirming to the requirements of relevant IS codes,labour,Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 6708.07 | 6708.07 | 30.799 | False | None | None | False | None | False | 206601.84793 | 0 | 3938133 | 152212 | None | PWD SR-2023-24-Vol.1-Page No.17-Item No.2.4.2 | Providing and laying in position Reinforced cement concrete for all Sub structures of building,Irrigation works,Sub structure works of bridges,Drain works & other parallel works from 0.50m to 3.50 m height.The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers,laid in layers,well compacted using needle vibrators,providing weep holes wherever necesary,including all lead & lifts,cost of all materials of quality,confirming to the requirements of relevant IS codes,labour,Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 8792.13 | 8792.13 | 48.84 | False | None | None | False | None | False | 429407.6292 | 0 | 3938134 | 152212 | None | PWD SR-2023-24 Vol.1-Page No.18-Item No.2.11 | Supplying,fitting and placing TMT FE 550/550D Steel Reinforcement including cost of all materials,machinery,labour,cleaning,straightening,cutting,bending,hooking,laping/welding joints,tying with binding wire/soft annealed steel wire and other ancilary operations complete as per drawing and technical specification.All other type of structures | Kgs | 81381.33 | 81381.33 | 2.931 | False | None | None | False | None | False | 238528.67823 | 0 | 3938135 | 152212 | None | PWD SR-2023-24 Vol.1-Page No.7-Item No.1.9 | Filling available excavated earth (excluding rock) in trenches,plinth,sides of foundations and other similar works etc.in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering,lead up to 50 m and lift upto 1.5 m. | Cum | 273.98 | 273.98 | 79.09 | False | None | None | False | None | False | 21669.0782 | 0 |
|
|
---|