createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1725626105636
version5
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee2160.00
emd146000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose21-09-2024 17:00:00
tenderQueryClose17-09-2024 11:30:00
technicalBidOpen23-09-2024 17:30:00
publishedDate09-09-2024 17:27:45
publishedByPostDUDC_EE_UK
publishedByUserKPE12421 - K M RAVIKUMAR
bidValidityPeriod90
noOfCalls1
preBidMeetingDate17-09-2024 11:30:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonBhaskar Gowda
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9448629028
tenderSupplierListNone
tenderSchedule
createdTs1725626105687
version6
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/OW/WORK_INDENT18913
titleImprovement of Buildings and other works for TMC Bhatkal Limits
descriptionAdditional works of Purakarmika Griha Bhagya Yojana. Additional work under Purakarmika Griha Bhagya Yojana.Construction of shade in front of Kokti Mahasati temple.Installation of sheets at the top of Vikala Chetana School.Replacement of main pipeline from Kadvinakatta Pump House and construction of Hanuman Nagar Bore Well. and drinking water system.Installation of light to Bunder road divider.
categoryWORKS
categoryTextWorks
ecv8621000.00
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2205
locationNameDMA District Urban Development Cell Uttara Kannada
provisionalAmount8621000.0
groupOverheadTotal1320443.72
fileNumbernaa1e86ist2022
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17256261060000NoneNoneOther WorksAdditional works of Purakarmika Griha Bhagya Yojana.3469834.72
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3937282152184NonePWD SR.2023.24.Vol.2.Page No.17.Item No.6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1467.21467.2235.329FalseNoneNoneFalseNoneFalse345274.70880
3937283152184NonePWD SR.2023.24.Vol.2.Page No.17.Item No.6.32Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1481.871481.8732.269FalseNoneNoneFalseNoneFalse47818.463030
3937284152184NonePWD SR.2023.24.Vol.2.Page No.17.Item No.6.33Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1392.51392.564.75FalseNoneNoneFalseNoneFalse90164.3750
3937285152184NonePWD SR.2023.24.Vol.2.Page No.17.Item No.6.33Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1406.291406.2984.389FalseNoneNoneFalseNoneFalse118675.406810
3937286152184NonePWD SR.2023.24.Vol.2.Page No.17.Item No.6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1236.481236.485.76FalseNoneNoneFalseNoneFalse7122.12480
3937287152184NonePWD SR.2023.24.Vol.2.Page No.42.Item No.8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm415.52415.52182.24FalseNoneNoneFalseNoneFalse75724.36480
3937288152184NonePWD SR.2023.24.Vol.2.Page No.42.Item No.8.8Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm419.67419.67345.28FalseNoneNoneFalseNoneFalse144903.65760
3937289152184NonePWD SR.2023.24.Vol.2.Page No.41.Item No.8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm330.4330.4572.23FalseNoneNoneFalseNoneFalse189064.7920
3937290152184NonePWD SR.2023.24.Vol.2.Page No.41.Item No.8.2.1Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm333.7333.7572.23FalseNoneNoneFalseNoneFalse190953.1510
3937291152184NonePWD SR.2023.24.Vol.2.Page No.71.Item No.10.14Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade completeSqm1238.721238.7246.99FalseNoneNoneFalseNoneFalse58207.45280
3937292152184NonePWD SR.2023.24.Vol.2.Page No.71.Item No.10.14Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade completeSqm1251.11251.146.99FalseNoneNoneFalseNoneFalse58789.1890
3937293152184NonePWD SR.2023.24.Vol.2.Page No.59.Item No.9.7.1Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tileSqm1395.521395.5213.33FalseNoneNoneFalseNoneFalse18602.28160
3937294152184NonePWD SR.2023.24.Vol.2.Page No.59.Item No.9.7.1Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tileSqm1409.471409.4713.33FalseNoneNoneFalseNoneFalse18788.23510
3937295152184NonePWD SR.2023.24.Vol.2.Page No.46.Item No.8.30Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm194.88194.88182.24FalseNoneNoneFalseNoneFalse35514.93120
3937296152184NonePWD SR.2023.24.Vol.2.Page No.46.Item No.8.30Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-chargeSqm196.82196.82345.28FalseNoneNoneFalseNoneFalse67958.00960
3937297152184NonePWD SR.2023.24.Vol.2.Page No.50.Item No.8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.Sqm123.2123.2572.23FalseNoneNoneFalseNoneFalse70498.7360
3937298152184NonePWD SR.2023.24.Vol.2.Page No.50.Item No.8.54.2Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 g/L of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. Two coats as per specifications and as per directions of Engineer in charge.Sqm124.43124.43572.23FalseNoneNoneFalseNoneFalse71202.57890
3937299152184NonePWD SR.2023.24.Vol.2.Page No.86.Item No.11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKg188.16188.16301.32FalseNoneNoneFalseNoneFalse56696.37120
3937300152184NonePWD SR.2023.24.Vol.2.Page No.85.Item No.11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKg190.04190.04301.32FalseNoneNoneFalseNoneFalse57262.85280
3937301152184NonePWD SR.2023.24.Vol.2.Page No.99.Item No.12.12Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.Cum139106.24139106.240.28FalseNoneNoneFalseNoneFalse38949.74720
3937302152184NonePWD SR.2023.24.Vol.2.Page No.99.Item No.12.12Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications.Cum140497.3140497.30.28FalseNoneNoneFalseNoneFalse39339.2440
3937303152184NonePWD SR.2023.24.Vol.2.Page No.99.Item No.12.15Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )Sqm8337.288337.287.56FalseNoneNoneFalseNoneFalse63029.83680
3937304152184NonePWD SR.2023.24.Vol.2.Page No.99.Item No.12.15Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures )Sqm8420.658420.657.56FalseNoneNoneFalseNoneFalse63660.1140
3937305152184NonePWD SR.2023.24.Vol.2.Page No.104.Item No.12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, lovered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottomrail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.Sqm2649.922649.926.3FalseNoneNoneFalseNoneFalse16694.4960
3937306152184NonePWD SR.2023.24.Vol.2.Page No.104.Item No.12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, lovered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottomrail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges.Sqm2676.412676.416.3FalseNoneNoneFalseNoneFalse16861.3830
3937307152184NonePWD SR.2023.24.Vol.2.Page No.111.Item No.12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.Mtr356.16356.1636.0FalseNoneNoneFalseNoneFalse12821.760
3937308152184NonePWD SR.2023.24.Vol.2.Page No.111.Item No.12.54Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.Mtr359.72359.7236.0FalseNoneNoneFalseNoneFalse12949.920
3937309152184NonePWD SR.2023.24.Vol.2.Page No.101.Item No.12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. -do- with both side prelamMtr2649.922649.9236.0FalseNoneNoneFalseNoneFalse95397.120
3937310152184NonePWD SR.2023.24.Vol.2.Page No.101.Item No.12.55.1Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 No of 75mm Aluminium hinges. -do- with both side prelamMtr2676.412676.4136.0FalseNoneNoneFalseNoneFalse96350.760
3937311152184NonePWD SR.2023.24.Vol.2.Page No.104.Item No.12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.No1137.921137.926.0FalseNoneNoneFalseNoneFalse6827.520
3937312152184NonePWD SR.2023.24.Vol.2.Page No.104.Item No.12.51Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications.No1149.291149.296.0FalseNoneNoneFalseNoneFalse6895.740
3937313152184NonePWD SR.2023.24.Vol.2.Page No.105.Item No.12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. completeNo134.4134.46.0FalseNoneNoneFalseNoneFalse806.40
3937314152184NonePWD SR.2023.24.Vol.2.Page No.105.Item No.12.60Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.No1178.241178.243.0FalseNoneNoneFalseNoneFalse3534.720
3937315152184NonePWD SR.2023.24.Vol.2.Page No.105.Item No.12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNo265.44265.4412.0FalseNoneNoneFalseNoneFalse3185.280
3937316152184NonePWD SR.2023.24.Vol.2.Page No.105.Item No.12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNo145.6145.66.0FalseNoneNoneFalseNoneFalse873.60
3937317152184NonePWD SR.2023.24.Vol.2.Page No.105.Item No.12.69.2Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc., 125mmNo272.16272.169.0FalseNoneNoneFalseNoneFalse2449.440
3937318152184NonePWD SR.2023.24.Vol.2.Page No.105.Item No.12.69.3Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc., 100mmNo241.92241.929.0FalseNoneNoneFalseNoneFalse2177.280
3937319152184NonePWD SR.2023.24.Vol.2.Page No.105.Item No.12.58Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. completeNo135.74135.746.0FalseNoneNoneFalseNoneFalse814.440
3937320152184NonePWD SR.2023.24.Vol.2.Page No.105.Item No.12.60Providing and fixing chromium plated brass night latch of approved quality including necessary screws etc. complete.No1190.021190.023.0FalseNoneNoneFalseNoneFalse3570.060
3937321152184NonePWD SR.2023.24.Vol.2.Page No.105.Item No.12.62Providing and fixing chromium plated brass handles of 100/125 mm with necessary screws etc. completeNo268.09268.0912.0FalseNoneNoneFalseNoneFalse3217.080
3937322152184NonePWD SR.2023.24.Vol.2.Page No.105.Item No.12.63Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. completeNo147.05147.056.0FalseNoneNoneFalseNoneFalse882.30
3937323152184NonePWD SR.2023.24.Vol.2.Page No.105.Item No.12.69.2Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc., 125mmNo274.88274.889.0FalseNoneNoneFalseNoneFalse2473.920
3937324152184NonePWD SR.2023.24.Vol.2.Page No.105.Item No.12.69.3Providing and fixing ISI marked oxidised M.S. single acting spring hinges with necessary screws etc., 100mmNo244.33244.339.0FalseNoneNoneFalseNoneFalse2198.970
3937325152184NonePWD SR.2023.24.Vol.2.Page No.84.Item No.11.26.1Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg154.56154.56108.145FalseNoneNoneFalseNoneFalse16714.89120
3937326152184NonePWD SR.2023.24.Vol.2.Page No.77.Item No.11.2Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in- Charge.Kg126.56126.5617.1FalseNoneNoneFalseNoneFalse2164.1760
3937327152184NonePWD SR.2023.24.Vol.2.Page No.21.Item No.7.7Providing & fixing reinforced by organic fibres and/or inorganic syntheticfibres cement 6 mm thick corrugated sheets (as per IS: 14871) roofing up to any pitch and fixing with polymer coated J, or L hooks, bolts and nuts 8 mm dia. G.I. plain and bitumen washers or with self drilling fastener and EPDM washers etc. complete (excluding the cost of purlins, rafters and trusses), including cutting sheets to size and shape wherever required as per design drawings.Sqm485.28485.2813.049FalseNoneNoneFalseNoneFalse6332.418720
3937328152184NonePWD SR.2023.24.Vol.2.Page No.77.Item No.11.5.2Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using flats 30x6mm for diagonal braces and central cross piece including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Sqm4798.554798.551.89FalseNoneNoneFalseNoneFalse9069.25950
3937329152184NonePWD SR.2023.24.Vol.2.Page No.109.Item No.12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm6405.286405.281.62FalseNoneNoneFalseNoneFalse10376.55360
3937330152184NonePWD SR.2023.24.Vol.2.Page No.109.Item No.12.85Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm6469.336469.331.62FalseNoneNoneFalseNoneFalse10480.31460
3937331152184NonePWD SR.2023.24.Vol.2.Page 62.Item No.9.21.2Providing and laying Vitrified tiles with thickness 9-10 mm in floor with different sizes with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mmSqm1386.561386.56121.48FalseNoneNoneFalseNoneFalse168439.30880
3937332152184NonePWD SR.2023.24.Vol.2.Page 62.Item No.9.21.2Providing and laying Vitrified tiles in floor with different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS : 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately). Size of Tile 600x600 mmSqm1400.421400.42121.48FalseNoneNoneFalseNoneFalse170123.02160
3937333152184NonePWD SR.2023.24.Vol.2.Page 149.Item No.15.1Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers as per the direction of the Engineer In charge.Sqm924.19924.19169.96FalseNoneNoneFalseNoneFalse157075.33240
3937334152184NoneS.R.Electrical 2023.24 Chapter.1, Item No.1.1.1Concealed Conduit System Supplying Heavy Gauge PVC Conduit pipe 19/20 mm dia 2mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes adhesive paste etc.and running before concreting the slab.The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipes ends should be covered using PVC end enclosures.run with 18SWG GI fish wire wherever necessary.19/20 mm dia 2 mm thickMtr69.069.0117.0FalseNoneNoneFalseNoneFalse8073.00
3937335152184NoneS.R.Electrical 2023.24 Chapter.1.Item No.1.2.2Concealed Conduit System Supplying Heavy Gauge PVC Conduit pipe 25 mm dia 2mm thick confirming to IS 2509 with suitable size bends,metal/PVC junction boxes adhesive paste etc,and running before concreting the slab.The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipes ends should be covered using PVC end enclosures.run with 18SWG GI fish wire wherever necessary.25 mm dia 2 mm thick Mtr78.078.039.0FalseNoneNoneFalseNoneFalse3042.00
3937336152184NoneS.R.Electrical 2023.24 Chapter.1, Item No.1.3.1Concealed conduit System,Supplying Heavy Gauge PVC Conduit Pipe 19/20mm dia 2mm thick with suitable size bends,metal/PVE junction boxes adhesive paste etc.,by groove cutting in the wall & fixing by using U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run through out the conduit wherever necessary.19/20 mm dia 2 mm thickMtr68.068.078.0FalseNoneNoneFalseNoneFalse5304.00
3937337152184NoneS.R.Electrical 2023.24 Chapter.1, Item No.1.3.2Concealed conduit System,Supplying Heavy Gauge PVC Conduit Pipe 25mm dia 2mm thick with suitable size bends,metal/PVE junction boxes adhesive paste etc.,by groove cutting in the wall & fixing by using U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run through out the conduit wherever necessary.25 mm dia 2 mm thickMtr79.079.078.0FalseNoneNoneFalseNoneFalse6162.00
3937338152184NoneS.R.Electrical 2023.24 Chapter.1, Item No.1.1.3Concealed conduit System,Supplying Heavy Gauge PVC Conduit Pipe 32mm dia 2.5 mm thick with Confirming to IS 2509 with suitable size bends,metal/PVC junction boxes adhesive paste etc.,and running before concreting the slab.The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosure.Run with 18SWG GI fish wire wherever necessary.32 mm dia 2.5 mm thickMtr106.0106.078.0FalseNoneNoneFalseNoneFalse8268.00
3937339152184NoneS.R.Electrical 2023.24 Chapter.3, Item No.3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall,including necessary rawl plugs,Machine/NF screws etc.,complete.Each103.0103.048.0FalseNoneNoneFalseNoneFalse4944.00
3937340152184NoneS.R.Electrical 2023.24 Chapter.3, Item No.3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall,including necessary rawl plugs,Machine/NF screws etc.,complete.Each124.0124.018.0FalseNoneNoneFalseNoneFalse2232.00
3937341152184NoneS.R.Electrical 2023.24 Chapter.3, Item No.3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall,including necessary rawl plugs,Machine/NF screws etc.,complete.Each173.0173.012.0FalseNoneNoneFalseNoneFalse2076.00
3937342152184NoneS.R.Electrical 2023.24 Chapter.3, Item No.3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.Each137.0137.096.0FalseNoneNoneFalseNoneFalse13152.00
3937343152184NoneS.R.Electrical 2023.24 Chapter.3, Item No.3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.Each161.0161.054.0FalseNoneNoneFalseNoneFalse8694.00
3937344152184NoneS.R.Electrical 2023.24 Chapter.3, Item No.3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.Each234.0234.048.0FalseNoneNoneFalseNoneFalse11232.00
3937345152184NoneS.R.Electrical 2023.24 Chapter.3, Item No.3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Each102.0102.060.0FalseNoneNoneFalseNoneFalse6120.00
3937346152184NoneS.R.Electrical 2023.24 Chapter.3, Item No.3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Each166.0166.024.0FalseNoneNoneFalseNoneFalse3984.00
3937347152184NoneS.R.Electrical 2023.24 Chapter.3, Item No.3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Each171.0171.048.0FalseNoneNoneFalseNoneFalse8208.00
3937348152184NoneS.R.Electrical 2023.24 Chapter.3, Item No.3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Each236.0236.012.0FalseNoneNoneFalseNoneFalse2832.00
3937349152184NoneS.R.Electrical 2023.24 Chapter.3, Item No.3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.Each156.0156.024.0FalseNoneNoneFalseNoneFalse3744.00
3937350152184NoneS.R.Electrical 2023.24 Chapter.2, Item No.2.1.1Point Wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC conduit /casing capping using 1100V grade, COPPER conductor flexible multi strand FRLS PVC insulated to 2X1.5 Sqmm cabale confirming to the GTP with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Nos285.0285.012.0FalseNoneNoneFalseNoneFalse3420.00
3937351152184NoneS.R.Electrical 2023.24 Chapter.2, Item No.2.1.2Point Wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC conduit /casing capping using 1100V grade, COPPER conductor flexible multi strand FRLS PVC insulated to 2X1.5 Sqmm cabale confirming to the GTP with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet/gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet.Nos394.0394.06.0FalseNoneNoneFalseNoneFalse2364.00
3937352152184NoneS.R.Electrical 2023.24 Chapter.3, Item No.3.1.2Supplying 6A flush type socket and 6Amps flush type SP switch either surface / flush mounting in existing gang box or in a 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required. as per IS 1293 and IS 3654Each147.0147.024.0FalseNoneNoneFalseNoneFalse3528.00
3937353152184NoneS.R.Electrical 2023.24 Chapter.2, Item No.2.3.1Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTPMtr19.019.0234.0FalseNoneNoneFalseNoneFalse4446.00
3937354152184NoneS.R.Electrical 2023.24 Chapter.2, Item No.2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTPMtr26.026.0117.0FalseNoneNoneFalseNoneFalse3042.00
3937355152184NoneS.R.Electrical 2023.24 Chapter.2, Item No.2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTPMtr42.042.0110.0FalseNoneNoneFalseNoneFalse4620.00
3937356152184NoneS.R.Electrical 2023.24 Chapter.2, Item No.2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTPMtr63.063.080.0FalseNoneNoneFalseNoneFalse5040.00
3937357152184NoneS.R.Electrical 2023.24 Chapter.11, Item No.11.3.2Supplying of .4'.feet -PVC Batten with integrated LED tube 20/22 W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRIgreather than 80. Power Input: 220-240V@ 50/60Hz & Power factorgreather than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.Each690.0690.012.0FalseNoneNoneFalseNoneFalse8280.00
3937358152184NoneS.R.Electrical 2023.24 Chapter.13, Item No.13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.Each122.0122.012.0FalseNoneNoneFalseNoneFalse1464.00
3937359152184NoneS.R.Electrical 2023.24 Chapter.5, Item No.5.7.3Supplying & fixing of porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers etc., complete. 63 AmpsEach401.0401.024.0FalseNoneNoneFalseNoneFalse9624.00
3937360152184NoneS.R.Electrical 2023.24Chapter.5, Item No.5.18.4Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing material sand 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10 K and complete wiring as required confirming to IEC60898.Each739.0739.012.0FalseNoneNoneFalseNoneFalse8868.00
3937361152184NoneS.R.Electrical 2023.24 Chapter.5, Item No.5.19.5Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.Each2932.02932.012.0FalseNoneNoneFalseNoneFalse35184.00
3937362152184NoneS.R.Electrical 2023.24 Chapter.5, Item No.5.20.1Supplying, fixing and wiring Residual current circuit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board.Each4277.04277.018.0FalseNoneNoneFalseNoneFalse76986.00
3937363152184NoneS.R.Electrical 2023.24 Chapter.5, Item No.5.42.2Fabricating supplying and mounting MS box made out 16 SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete.Sq CM0.430.432000.0FalseNoneNoneFalseNoneFalse860.00
3937364152184NoneS.R.Electrical 2023.24 Chapter.11, Item No.11.11.4Supplying & fixing of retrofit type.LED bulb . W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIgreather than70%. efficacygreather than 80 lumen per W, lifegreather than25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PFgreather than 0.95, power loss should less than 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. Each154.0154.012.0FalseNoneNoneFalseNoneFalse1848.00
3937365152184NoneS.R.Electrical 2023.24 Chapter.11, Item No.11.11.5Supplying & fixing of retrofit type.LED bulb . W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRIgreather than70%. efficacygreather than 80 lumen per W, lifegreather than25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PFgreather than 0.95, power loss should less than5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. Each269.0269.012.0FalseNoneNoneFalseNoneFalse3228.00
3937366152184NoneS.R.Electrical 2023.24 Chapter.5 Item No 5.44.1Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparentPolycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 300 mm x 300 mm x 214 mm mmEach4512.04512.06.0FalseNoneNoneFalseNoneFalse27072.00
3937367152184NoneUniSR 2023.24, Vol.VI, Item No.32.04 Code.2870561.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975No88418.088418.00.02FalseNoneNoneFalseNoneFalse1768.360
3937368152184NoneBESCOM Part III 2023.24, Item No Item No.51.01GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer completeMinimum Weight of GI Pipe: 7.3 KgNo743.0743.06.0FalseNoneNoneFalseNoneFalse4458.00
3937369152184NoneS.R.Electrical 2023.24, Item No.51.02,Code.600095Grounding Material Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg eachNo676.0676.01.0FalseNoneNoneFalseNoneFalse676.00
3937370152184NoneS.R.Electrical 2023.24, Item No.51.03,Code.607054Grounding Material Good Quality Salt for grounding purposes packed in 50 Kg gunny bagBag310.0310.01.0FalseNoneNoneFalseNoneFalse310.00
3937371152184NoneS.R.Electrical 2023.24, Item No.53.03LT Single Phase 5-30 Amps, DLMS Complaint Static Energy Meter, 1.0 Accuracy Class (Used for LT-2, LT-3 & LT-5 Installations)No958.0958.07.0FalseNoneNoneFalseNoneFalse6706.00
3937372152184NonePWD.2023.24.Vol.2.Page No.122.Item No.13.32.2Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.Mtr424.48424.4840.0FalseNoneNoneFalseNoneFalse16979.20
3937373152184NonePWD.2023.24.Vol.2.Page No.122.Item No.13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.Mtr534.24534.2435.0FalseNoneNoneFalseNoneFalse18698.40
3937374152184NonePWD SR.2023.24.Vol.2.Page No.117.Item No.13.1.1.Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee,including cutting and threading the pipe etc. complete :No680.96680.9612.0FalseNoneNoneFalseNoneFalse8171.520
3937375152184NonePWD SR.2023.24.Vol.2.Page No.120.Item No.13.18.2.Providing and fixing PTMT stop cock of approved quality and colour 20 mm nominal bore,89 mm long,weighing not less than 88 gNo161.28161.2836.0FalseNoneNoneFalseNoneFalse5806.080
3937376152184NonePWD SR.2023.24.Vol.2.Page No.117.Item No.13.4.1.Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :25 mm nominal boreNo614.88614.8812.0FalseNoneNoneFalseNoneFalse7378.560
3937377152184NonePWD SR.2023.24.Vol.2.Page No.120.Item No.13.17.1Providing and fixing PTMT bib cock of approved quality and colour. 15mm nominal bore,86 mm long,weighing not less than 88 g Each176.96176.9636.0FalseNoneNoneFalseNoneFalse6370.560
3937378152184NonePWD SR.2023.24.Vol.2.Page No.119.Item No.13.11.2Providing and fixing G.I. Union in existing G.I. pipe line,cutting and threading the pipe and making long screws,including excavation,refilling the earth or cutting of wall and making good the same complete wherever required : 20 mm nominal bore Set632.8632.824.0FalseNoneNoneFalseNoneFalse15187.20
3937379152184NonePWD SR.2023.24.Vol.2.Page No.115.Item No.13.6.1.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 25 mm nominal bore Horizontal No694.4694.412.0FalseNoneNoneFalseNoneFalse8332.80
3937380152184NonePWD SR.2023.24.Vol.2.Page No.123.Item No.13.34 Providing and placing on terrace (at all floor levels) polyethylene water storage tank,IS 12701 marked,with cover and suitable locking arrangement and making necessary holes for inlet,outlet and overflow pipes but without fittings and the base support for tank.Ltr8.968.963000.0FalseNoneNoneFalseNoneFalse26880.00
3937381152184NonePWD SR.2023.24.Vol.2.Page No.125.Item No.13.51Constructing masonry Chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement :4 coarse sand) with C. I. surface box 100x100 x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size),i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size ) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12mm thick,finished with a floating coat of neat cement complete as per standard design : With common burnt clay (non modular) bricks of class designation 3.5Each1910.721910.7212.0FalseNoneNoneFalseNoneFalse22928.640
3937382152184NonePWD SR.2023.24.Vol.2.Page No.131.Item No.14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap,10 litre low level white P.V.C. flushing cistern,including flush pipe,with manually controlled device (handle lever) conforming to IS : 7231,with all fittings and fixtures complete,including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsEach5470.085470.086.0FalseNoneNoneFalseNoneFalse32820.480
3937383152184NonePWD SR.2023.24.Vol.2.Page No.125.Item No.13.48Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A,including jointing with seal ring conforming to IS : 5382,leaving 10 mm gap for thermal expansion,(i) Single socketed pipes 100 mm diameterMtr325.92325.9270.0FalseNoneNoneFalseNoneFalse22814.40
3937384152184NonePWD SR.2023.24.Vol.2.Page No.119.Item No.13.10.5Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :40 mm nominal boreNos570.08570.0824.0FalseNoneNoneFalseNoneFalse13681.920
3937385152184NonePWD SR.2023.24.Vol.5.Page No.113.Item No.10.1.6Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite,rolling and lowering into trenches,laying true to line and level and perfect linking at joints,testing and commissioning,including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type,with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 90mm dia.,6 kg/sqcm & class 3Mtr329.28329.2850.0FalseNoneNoneFalseNoneFalse16464.00
3937386152184NonePWD SR.2023.24.Vol.5.Page No.113.Item No.10.1.7Providing PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite,rolling and lowering into trenches,laying true to line and level and perfect linking at joints,testing and commissioning,including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type,with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. complete For: PVC pipes 110mm dia.,6 kg/sqcm & class 3Mtr460.32460.3235.0FalseNoneNoneFalseNoneFalse16111.20
3937387152184NonePWD SR.2023.24.Vol.2.Page No.136.Item No.14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Each1366.41366.46.0FalseNoneNoneFalseNoneFalse8198.40
3937388152184NonePWD SR.2023.24.Vol.2.Page No.132.Item No.14.7.2Providing and fixing wash basin with C.I. brackets,15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern,including painting of fittings and brackets,cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapEach2868.322868.326.0FalseNoneNoneFalseNoneFalse17209.920
3937389152184NonePWD SR.2023.24.Vol.2.Page No.134.Item No.14.10.2.2Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm,including painting of fittings and brackets,cutting and making good the walls wherever required :610x460 mm bowl depth 200 mmEach3180.83180.86.0FalseNoneNoneFalseNoneFalse19084.80
3937390152184NonePWD SR.2023.24.Vol.5.Page No.157.Item No.13.40.1Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments 2 HP,Size 65x50 Head 13M,Discharge 462 LPMEach17483.217483.26.0FalseNoneNoneFalseNoneFalse104899.20
17256261060000NoneNoneOther WorksConstruction of shade in front of Kokti Mahasati temple.253854.96
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3937391152185NonePWD SR.2023.24.Vol.1.Page No.8.Item No.1.14.1Mechanical Means Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3 mCum114.24114.2410.0FalseNoneNoneFalseNoneFalse1142.40
3937392152185NonePWD SR.2023.24.Vol.1.Page No.15.Item No.2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregatesCum6707.686707.681.0FalseNoneNoneFalseNoneFalse6707.680
3937393152185NonePWD SR.2023.24.Vol.1.Page No.16.Item No.2.4.2Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7081.767081.762.43FalseNoneNoneFalseNoneFalse17208.67680
3937394152185NonePWD SR.2023.24.Vol.1.Page No.16.Item No.2.5.1Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7425.67425.60.36FalseNoneNoneFalseNoneFalse2673.2160
3937395152185NonePWD SR.2023.24.Vol.2.Page No.77.Item No.11.2Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-inCharge.Kg126.56126.56317.79FalseNoneNoneFalseNoneFalse40219.50240
3937396152185NonePWD SR.2023.24.Vol.2.Page No.26.Item No.7.38Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.Sqm636.16636.1636.0FalseNoneNoneFalseNoneFalse22901.760
3937397152185NonePWD SR.2023.24.Vol.2.Page No.27.Item No.7.39.6Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Gutter (600 mm over all girth)Mtr1202.881202.8810.0FalseNoneNoneFalseNoneFalse12028.80
3937398152185NonePWD SR.2023.24.Vol.2.Page No.48.Item No.8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm128.8128.81172.15FalseNoneNoneFalseNoneFalse150972.920
17256261060000NoneNoneOther WorksInstallation of sheets at the top of Vikala Chetana School.613948.37
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3937399152186NonePWD SR.2023.24.Vol.1.Page No.8.Item No.1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m,as per drawing and technical specifications,including setting out,shoring,strutting,barricading,caution lights,including dressing of excavated surfaces,disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour,tools,usage of machinery & other appurtenaces required to complete the workCum114.24114.243.072FalseNoneNoneFalseNoneFalse350.945280
3937400152186NonePWD SR.2023.24.Vol.1.Page No.15.Item No.2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed,laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators,including all lead & lifts,cost of all materials of quality,labour,Usage charges of machineries,curing,and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Cum6963.046963.040.32FalseNoneNoneFalseNoneFalse2228.17280
3937401152186NonePWD SR.2023.24.Vol.1.Page No.15.Item No.2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers,well compacted using needle vibrators,including all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes ,labour,Usage charges of machinery,curing and all the other appurtenances required to complete the work as per technical specifications. (The cost 'of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7544.47544.40.64FalseNoneNoneFalseNoneFalse4828.4160
3937402152186NonePWD SR.2023.24.Vol.1.Page No.16.Item No.2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building ,Road works,Water works,Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers,well compacted using needle vibrators. The cost includes all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes ,labour,Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement,dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum12454.2612454.260.41FalseNoneNoneFalseNoneFalse5106.24660
3937403152186NonePWD SR.2023.24.Vol.1.Page No.16.Item No.2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building ,Road works,Water works,Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers,well compacted using needle vibrators. The cost includes all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes ,labour,Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement,dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11769.9611769.960.38FalseNoneNoneFalseNoneFalse4472.58480
3937404152186NonePWD SR.2023.24.Vol.1.Page No.16.Item No.2.5.2Providing and laying in position Reinforced cement concrete for all Super structures of building ,Road works,Water works,Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers,well compacted using needle vibrators. The cost includes all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes ,labour,Usage charges of machinery,curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement,dowel bars & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11085.6611085.662.45FalseNoneNoneFalseNoneFalse27159.8670
3937405152186NonePWD SR.2023.24.Vol.2.Page No.18.Item No.2.11Supplying,fitting and placing TMT FE 550/550D Steel Reinforcement including cost of all materials,machinery,labour,cleaning,straightening,cutting,bending,hooking,laping/welding joints,tying with binding wire/soft annealed steel wire and other ancilary operations complete as per drawing andtechnical specificationTonne100191.84100191.840.346FalseNoneNoneFalseNoneFalse34666.376640
3937406152186NonePWD SR.2023.24.Vol.2.Page No.84.Item No.11.25.2Providing and fixing Steel work welded in built up sections/framed work,including cutting,hoisting,fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings,frames,guard bar,ladder,railings,brackets,gates and similar works including cost of materials,labour,usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kgs152.32152.32284.91FalseNoneNoneFalseNoneFalse43397.49120
3937407152186NonePWD SR.2023.24.Vol.1.Page No.15.Item No.2.2.3Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers,well compacted using needle vibrators,including all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes ,labour,Usage charges of machinery,curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum12063.7412063.740.486FalseNoneNoneFalseNoneFalse5862.977640
3937408152186NonePWD SR.2023.24.Vol.1.Page No.16.Item No.2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building ,Road works,Water works,Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers,well compacted using needle vibrators. The cost includes all lead & lifts,cost of all materials,quality confirming to the requirements of relevant IS codes ,labour,Usage charges of machinery,curing andall other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement,dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarseaggregatesCum11880.9611880.961.05FalseNoneNoneFalseNoneFalse12475.0080
3937409152186NonePWD SR.2023.24.Vol.2.Page No.77.Item No.11.2Providing and fixing Structural Steel work riveted,bolted or welded in built up sections,trusses and framed work,including cutting,hoisting,fixing in position and applying a priming coat of approved steel primer all complete including cost of materials,labour,usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kgs126.56126.561027.401FalseNoneNoneFalseNoneFalse130027.870560
3937410152186NonePWD SR.2023.24.Vol.2.Page No.26.Item No.7.38Providing and fixing precoated galvanised iron profile sheets (size,shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277,in 240 mpa steel grade,5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal,complete upto any pitch in horizontal/vertical or curved surfaces,excluding the cost of purlins,rafters and trusses and including cutting to size and shape wherever required.Sqm636.16636.16133.5FalseNoneNoneFalseNoneFalse84927.360
3937411152186NonePWD SR.2023.24.Vol.2.Page No.26.Item No.7.39.2Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness,Zinc coating 120 grams per m2 as per IS: 277,in 240 mpa steel grade,5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/self tapping screws complete : Flashings/Aprons.( Upto 600 mm)Mtr462.56462.5616.0FalseNoneNoneFalseNoneFalse7400.960
3937412152186NoneCSR.2023.24.Vol.2.Page No.47.Item No.8.33.3Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90L/10 sqm over an under coat of primer applied @ 0.80 L/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil,grease,dirt and foreign matter,cost of materials,labour complete as per specifications and as per directions of Engineer-in-charge.Sqm155.68155.68240.444FalseNoneNoneFalseNoneFalse37432.321920
3937413152186NoneCSR.2023.24.Vol.2.Page No.17.Item No.6.33Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/cum and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part-I)-2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials,labour,scaffolding and curing,usage charges of machinery etc complete as per specifications.Sqm1378.721378.72123.459FalseNoneNoneFalseNoneFalse170215.392480
3937414152186NoneCSR.2023.24.Vol.2.Page No.42.Item No.8.6.1Providing 12 mm cement plaster with Cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement to brick masonry including rounding off corners wherever required smooth rendering,providing and removing scaffolding,including cost of materials,labour,curing complete as per specifications and as per directions of Engineer-in-charge.Sqm361.76361.76119.959FalseNoneNoneFalseNoneFalse43396.367840
17256261060000NoneNoneOther WorksReplacement of main pipeline from Kadvinakatta Pump House and construction of Hanuman Nagar Bore Well. and drinking water system.2116479.69
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3937415152187NonePWD SR.2023.24.Vol.5.Page No.200.Item No.16.36Clearing and grubbing land including uprooting rank vegetable grass,bushes,shrubs,saplings and trees upto 300mm girth by manual means,in areas of light jungle,removal of stumps,disposal of unserviceable materials,stacking of serviceable materials from road boundary etc. including cost of labour charges,all lead and lifts,etc. complete as directed by the Engineer in chargeSqm20.1620.16585.0FalseNoneNoneFalseNoneFalse11793.60
3937416152187NonePWD SR.2023.24.Vol.5.Page No.19.Item No.2.13.5Removing and cleaning the CI/DI pipes and specials including jointing materials,washing (excluding valves) etc. for 250mm dia. pipes & specialsRmtr141.12141.12390.0FalseNoneNoneFalseNoneFalse55036.80
3937417152187NonePWD SR.2023.24.Vol.5.Page No.19.Item No.2.13.5Removing and cleaning the CI/DI pipes and specials including jointing materials,washing (excluding valves) etc. for 150mm dia. pipes & specialsRmtr141.12141.1220.0FalseNoneNoneFalseNoneFalse2822.40
3937418152187NonePWD SR.2023.24.Vol.5.Page No.51.Item No.4.1.4Providing and laying Ductile Iron pipes of class - conforming to IS 8329:2000 with latest amendments,conveyiing to work site,rolling and lowering into trenches,laying true to line,level and perfect linking at joints,testing and commissioning,including loading and unloading at both destinations,cutting of pipes wherever necessary,jointing with DI specials (excluding cost of specials) and rubber gaskets,cleaning the socket and spigot end with soap solution,applying soft soap to the socket and spigot ends before insertion of rubber gaskets,jacking and fixing in perfect conditions etc. The cost to include soap solution,soft soap,waste etc. and giving necessary hydraulic test to the required pressure as per ISS with all lead and lifts and cost of all jointing materials. (The contractor will make his own arrangements for water for testing. Earth work excavation in trenches to be measured and paid for seperately) Note: In sewerage projects for internal cement mortal lining(CML)of DI pipes,if High Alumina Cement(HAC)as recommended in Annexure B clause 16.3 of IS8329:2000 is considered in place of Slag or Sulphate Resistance Cement(SRC ),the cost of pipes may be increased by 5-6% from the prices listed.Rmtr3516.83516.8390.0FalseNoneNoneFalseNoneFalse1371552.00
3937419152187NonePWD SR.2023.24.Vol.5.Page No.51.Item No.4.1.2Providing and laying Ductile Iron pipes of class - conforming to IS 8329:2000 with latest amendments,conveying to work site,rolling and lowering into trenches,laying true to line,level and perfect linking at joints,testing and commissioning,including loading and unloading at both destinations,cutting of pipes wherever necessary,jointing with DI specials (excluding cost of specials) and rubber gaskets,cleaning the socket and spigot end with soap solution,applying soft soap to the socket and spigot ends before insertion of rubber gaskets,jacking and fixing in perfect conditions etc. The cost to include soap solution,soft soap,waste etc. and giving necessary hydraulic test to the required pressure as per ISS with all lead and lifts and cost of all jointing materials. (The contractor will make his own arrangements for water for testing. Earth work excavation in trenches to be measured and paid for seperately) Note: In sewerage projects for internal cement mortal lining(CML)of DI pipes,if High Alumina Cement(HAC)as recommended in Annexure B clause 16.3 of IS8329:2000 is considered in place of Slag or Sulphate Resistance Cement(SRC ),the cost of pipes may be increased by 5-6% from the prices listed.Rmtr2257.922257.9220.0FalseNoneNoneFalseNoneFalse45158.40
3937420152187NonePWD SR.2023.24.Vol.5.Page No.5.Item No.1.5.8Suppling Ductile Iron Push on special confirming to IS 9523:2000. All Socketed D.I. Un-Equal Tees 250mm X 100mmNo7008.967008.965.0FalseNoneNoneFalseNoneFalse35044.80
3937421152187NonePWD SR.2023.24.Vol.5.Page No.133.Item No.11.15.11Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments,1 No. screwed in bonnet inside screw,rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 150 mm dia GM (Copper alloy) Gate valvesEach2936.642936.643.0FalseNoneNoneFalseNoneFalse8809.920
3937422152187NonePWD SR.2023.24.Vol.5.Page No.130.Item No.11.8.11Supply and delivery at site wrought middle steel (galvanized) GI bend confirming to IS 1239-II,1991 with latest amendments if any.For 150 mm dia GI BENDEach598.08598.083.0FalseNoneNoneFalseNoneFalse1794.240
3937423152187NonePWD SR.2021.22.Vol.5.Page No.129.Item No.11.6.11Supply and delivery at site wrought middle steel (galvanized) GI bend confirming to IS 1239-II,1991 with latest amendments if any.For 150 mm dia GI collarEach712.32712.324.0FalseNoneNoneFalseNoneFalse2849.280
3937424152187NonePWD SR.2021.22.Vol.3.Page No.78.Item No.8.54Providing and fixing board displaying information,such as 'Name of work,Tender cost,Name of Contractor,Work completion and liability period etc,having rectangular shape of 1.20m x 0.90m size made out 18 gauge (1.25mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stove enamel on back side and border/messages/symbols etc. with approved colour shade paint complete,on M.S.angle of size 35 x 35 x 3 mm frame with properly cross braced M.S. angles of size 35mmx35mmx3mm duly painted including Two M.S. angle iron posts of size 65 mm x 65 mm x 6 mm,3.65 m long painted with alternate black and white bands of 25 cm width including all fixtures etc.and fixing the boards in 1:4:8 oncrete block of size 60 cm x 60 cm x 75 cm including,excavation,refilling,transportation,and labour etc complete. Spec. No. As directed by Engineer in Charge & MoRTH specification 804No10080.010080.01.0FalseNoneNoneFalseNoneFalse10080.00
3937425152187NonePWD SR.2023.24.Vol.9.Page No.60.Item No.1.10.3Suppling Ductile Iron Push on special confirming to IS 9523:2000.All D.I. Flanged MJ COLLAREach1966.721966.722.0FalseNoneNoneFalseNoneFalse3933.440
3937426152187NonePWD SR.2023.24.Vol.9.Page No.60.Item No.1.10.3Suppling Ductile Iron Push on special confirming to IS 9523:2000.All D.I. Flanged MJ COLLAREach3551.523551.524.0FalseNoneNoneFalseNoneFalse14206.080
3937427152187None4.2.1Fabricating,supplying and erection of. ms long hot dip Galvanized Octagonal hot dip Pole with BSEN10025 grade S355JO steel plate for shaft,IS2062 for base plate with door opening arrangements,including suitable boards,Bakelite sheet and MCBs as per IS specification suitable to withstand the wind speed of 47m/s for. m Pole in single section and single joint welded as per IS9595/IS10178 AWS having dimensions bottom. mm,top. mm with 3mm thick,suitable base plate and 4 Nos of. long J bolts along with template and the Pole shall be hot dip galvanized in single dipping with not less than 65 micron as per ASTM-A123 and 153 etc.,(excluding foundation) as per drawing appended. 3 m.Top 70 mm and Bottom 94 mm dia 5 mm thicknessEach6300.06300.04.0FalseNoneNoneFalseNoneFalse25200.00
3937428152187None11.9.2Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material,delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%,CCT greather than 5500K,IP 66 optical and electrical compartment & impact resistance of complete luminaire greather than IK08. Power Factor greather than 0.9 with mains,Surge Protection- Min 5KV along with Over voltage/ Overload,short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598,LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency greather than 1301m/w,nominal CRI greather than 75. Luminaire manufacturer should have in- house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark/name shall be Engraved/Embossing on the die cast housing/Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should LED Floodlight 100WEach9486.09486.03.0FalseNoneNoneFalseNoneFalse28458.00
3937429152187None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade,multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.4 mm2 Mtr63.063.080.0FalseNoneNoneFalseNoneFalse5040.00
3937430152187None5.48Supplying and fixing Microprocessor Based Astronomical timer Switch with using necessary bolts,nuts and washers. Each4843.04843.01.0FalseNoneNoneFalseNoneFalse4843.00
3937431152187None1.1.2Supplying heavy gauge PVC conduit pipe . dia mm thick confirming to IS 2509 with suitable size bends,junction boxes,adhesive paste etc,and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. 25 mm dia 2 mm thick Mtr81.081.010.0FalseNoneNoneFalseNoneFalse810.00
3937432152187None5.18.650-63 A DP Each1102.01102.01.0FalseNoneNoneFalseNoneFalse1102.00
3937433152187None5.9.3Supplying and fixing HRC fuse units base on existing switch/panel board. 100 to 300 A Each919.0919.01.0FalseNoneNoneFalseNoneFalse919.00
3937434152187None5.20.8Supplying,fixing and wiring Residual current circ uit breaker (RCCB) 240/450V upto 300mA sensitivity on existing wood/ panel board. 32-40 A 2 pole Each5147.05147.01.0FalseNoneNoneFalseNoneFalse5147.00
3937435152187None12.60.1Supplying & Fixing Chemical earthling for grounding. Conduits,IC cut-outs & other equipments backfill compound which is non-corrosive,thermally conductive,potential to permissible limits,superior Fault conduction capacity,non-toxic,weather resistance & capable of achieving ohmic value less than one ohm. Using 4ft. Copper bonded rod with backfill compound" Each4528.04528.01.0FalseNoneNoneFalseNoneFalse4528.00
3937436152187None12.58.2 GI/Copper strips for grounding connections,using necessary fixing materials as required. 25 x 3 mm GI strip Mtr85.085.010.0FalseNoneNoneFalseNoneFalse850.00
3937437152187None12.58.251.1 kV,XLPE or Heat resistant PVC insulated,PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1,Armouring strip thickness and resistivity as per IS-3975 16 Sqmm,4 Core,(11 GI Strips.4 x 0.8 mm) Km141842.0141842.00.08FalseNoneNoneFalseNoneFalse11347.360
3937438152187NonePWD SR.2023.24.Vol.5.Page No.142.Item No.12.24Labour charges for Lifting of non functioning submersible pump set along with cable and GI pipes (Each length = 6m)). for 50 mmJob256.48256.4816.666FalseNoneNoneFalseNoneFalse4274.495680
3937439152187NonePWD SR.2023.24.Vol.5.Page No.140.Item No.12.6Re-drilling of filled-up borewell,including yield test at final depthRmtr497.28497.28200.0FalseNoneNoneFalseNoneFalse99456.00
3937440152187NonePWD SR.2023.24.Vol.5.Page No.143.Item No.12.32Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments,electrical resistance welded steel tubes,material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium dutyRmtr2164.962164.9620.0FalseNoneNoneFalseNoneFalse43299.20
3937441152187NonePWD SR.2023.24.Vol.5.Page No.143 Item No.12.33Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendmentsEach168.0168.05.0FalseNoneNoneFalseNoneFalse840.00
3937442152187NonePWD SR.2023.24.Vol.5.Page No.155 143.Item No.12.34Providing and laying at site of work MS casing caps as per IS 1239 (part II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing,if any etc. complete with all lead and lifts and as directed by the Engineer in chargeEach183.68183.681.0FalseNoneNoneFalseNoneFalse183.680
3937443152187NonePWD SR.2023.24.Vol.5.Page No.153.Item No.13.18.4Providing,supplying to work site,Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase,SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 15.00 HP.155 LPM @ 210 m = 15 STG Outlet Dia.2.00Each69246.2469246.241.0FalseNoneNoneFalseNoneFalse69246.240
3937444152187NonePWD SR.2023.24.Vol.5.Page No.154 Item No.13.22.2Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core (sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments 1x3x2.5 m2Rmtr95.295.2200.0FalseNoneNoneFalseNoneFalse19040.00
3937445152187NonePWD SR.2023.24.Vol.5.Page No.162.Item No.13.25.1Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments Size 50 mmEach1400.01400.02.0FalseNoneNoneFalseNoneFalse2800.00
3937446152187NonePWD SR.2023.24.Vol.5.Page No.156 Item No.13.32Labour charges for Erection,Electrification and commissioning of Pump sets,including aligning and balancing of all items including supply and erection of two pair of supporting clamps,bore well caps,cable clips and water tight gland cable protectors,bolts,nuts,valve and gauges,tools and equipments etc.,involved in the job as per specifications,with necessary tests as per specifications,with testing of as per instructions of engineer incharge of work.Job7280.07280.01.0FalseNoneNoneFalseNoneFalse7280.00
3937447152187NonePWD SR.2023.24.Vol.5.Page No.155 Item No.13.23.3Supply,installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No,Analog Ammeter,1 No Analog Voltmeter 1ni with Phase selector switch,Isolating switch OUTGOINGfor Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor,under voltage over Volage,under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL Direct Online Starter 2) S-D- Star Delta Starter 6 to 15 HP pumpsEach17808.017808.01.0FalseNoneNoneFalseNoneFalse17808.00
3937448152187NonePWD SR.2023.24.Vol.5.Page No.155 Item No.13.30Supply and delivery at site Accessories for Single Phase pumpset like SS Groove Nipples,SS Studs & Nuts,Screw Clips &water proof Insulation Tape etc complete with ISI markEach5040.05040.01.0FalseNoneNoneFalseNoneFalse5040.00
3937449152187None5.35Supplying,fixing and wiring Electronic Trivector Meter (ETV) 5to32/63A three phase4 wire whole current class-1 Accuracy Energy Meter.Each6389.66389.61.0FalseNoneNoneFalseNoneFalse6389.60
3937450152187NonePWD SR.2023.24.Vol.5.Page No.157.Item No.13.39Earthing: Supplying and fixing and wiring earth electrode for grounding circuits IC cutouts and other equipments on the meter board in the pit. The pits should be filled up with equal proportion of salt and charcoal 150mm around the pipe to complete depth. The connection from the pipe to the conduits etc. is to established through GI wire of sizes as per clause 7.3.3 of IS 732 using 12mm bolts,nuts,washers and check nuts,the pipe shall have 16 through holes of 12mm dia.Job4200.04200.01.0FalseNoneNoneFalseNoneFalse4200.00
3937451152187NoneSR.2022.23,Part.3,Page No.9.Item No.32.101.1 kV,XLPE or Heat resistant PVC insulated,PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1,Armouring strip thickness and resistivity as per IS-3975 35 Sqmm,4 Core,(15 GI Strips.4 x 0.8 mm)Km197198.4197198.40.23FalseNoneNoneFalseNoneFalse45355.6320
3937452152187NoneSR.20223.24,Part.3,Page No.10.Item No.Epoxy Terminating Kit (Pothead) suitable for 1.1 kV,LTUG Cable Up to 4C x 50 SqmmKm362.88362.881.0FalseNoneNoneFalseNoneFalse362.880
3937453152187NoneSR.2022.23,Part.4,Page No.52 of 81. Item No.21.06Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff HT Cable 35 to 95 SqmmKm34875.6834875.680.2FalseNoneNoneFalseNoneFalse6975.1360
3937454152187NoneSR.2023.24,Part.4,Page No.63 of 81.Item No.29.02Earth work excavation for cable trench of 0.5 to 0.75 Mtr. Width and Depth upto 1 Mtr including trial pits,depositing on bank upto a lead of 50 Mtr,Supplying and Displaying necessary Danger Boards and Lighting,Using sight Rails and Sign Boards at every 100 Mtr wherever necessary as directed. Ordinary SoilCum291.2291.2135.0FalseNoneNoneFalseNoneFalse39312.00
3937455152187NoneR.2022.23,Part.4,Page No.63 of 81. Item No.29.07Refilling the cable trenches with selected available earth from trench excavation including watering,consolidation in layers of 15 cm. Thickness including depositing of the surplus earth with a lead of 200 MtrCum64.9664.96135.0FalseNoneNoneFalseNoneFalse8769.60
3937456152187NonePWD SR.2023.24.Vol.5.Page No.128.Item No.11.3.6Providing,Laying and Fixing GI pipes conforming to IS 1239:1990 with latest amendments complete with GI fittings (excluding the cost of fittings) with cuts and threads wherever necessary,including testing for water tightness,with all lead and commissioning. (contractor will make his own arrangements for procuring water for testing) Heavy Duty GI pipe of 50mm diaRmtr760.48760.48100.0FalseNoneNoneFalseNoneFalse76048.00
3937457152187NonePWD SR.2023.24.Vol.5.Page No.66.Item No.2.6.5Labour charges for laying and jointing GI pipes with earth work including fixing collars,elbows,tees,bends,gland cocks and other fittings with cuts and threads,white lead paints wherever necessary,conveying the materials from office to workspot and retuning the surplus materials from workspot to stores for:50mm dia. GI pipes & specials.Rmtr35.8435.84100.0FalseNoneNoneFalseNoneFalse3584.00
3937458152187NonePWD SR.2023.24.Vol.1.Page No.15.Item No.2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed,laid in layers not exceeding 150 mm thickness,well compacted using plate vibrators,including all lead & lifts,cost of all materials of quality,labour,Usage charges of machineries,curing,and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately). Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6707.686707.680.729FalseNoneNoneFalseNoneFalse4889.898720
17256261060000NoneNoneOther WorksInstallation of light to Bunder road divider.846438.54
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3937459152188NonePWD SR.2023.24 .Vol.3.Page No.13.Item No.2.27Removal of Telephone/Electric Poles and Lines Removal of telephone/ Electric poles including excavation and dismantling of foundation concrete and lines under the supervision of concerned department, disposal with all lifts and lead and stacking the serviceable and unserviceable material separatelyCum379.68379.6818.0FalseNoneNoneFalseNoneFalse6834.240
3937460152188NonePWD SR.2023.24.Vol.1.Page No.8.Item No.1.14.1Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usageof machinery & other appurtenaces required to complete the workCum114.24114.2418.0FalseNoneNoneFalseNoneFalse2056.320
3937461152188NonePWD SR.2023.24.Vol.1.Page No.15.Item No.2.1.3Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing,and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6707.686707.681.8FalseNoneNoneFalseNoneFalse12073.8240
3937462152188NonePWD SR.2023.24.Vol.1.Page No.15.Item No.2.2.1Providing and laying in position Reinforced cement concrete for all Foundation works. he granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials,quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7604.757604.754.374FalseNoneNoneFalseNoneFalse33263.17650
3937463152188NonePWD SR.2023.24.Vol.1.Page No.16.Item No.2.3.1Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum12038.9912038.991.118FalseNoneNoneFalseNoneFalse13459.590820
3937464152188NonePWD SR.2023.24.Vol.1.Page No.18.Item No.2.11 HSupplying, fitting and placing TMT FE 550/550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire/soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. All other type of structuresKg88492.3288492.320.522FalseNoneNoneFalseNoneFalse46192.991040
3937465152188NonePWD SR.2023.24.Vol.1.Page No.7.Item No.1.9Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum297.92297.9211.826FalseNoneNoneFalseNoneFalse3523.201920
3937466152188NonePWD SR.2023.24.Vol.2.Page No.84.Item No.11.25.2Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg152.32152.3218.0FalseNoneNoneFalseNoneFalse2741.760
3937467152188None4.3Supply and erection of 14 Feet Height Street Light Pole 14 Feet Height Street Light Pole on suitable cement concrete foundation with 2.5 Feet height dia 5mm cast iron decorative round pedestal as per design weighing not less than 37 Kgs, the pedestal shall be fitted with Class 'C' G.I. Pipe 7 Feet height 75mm outer dia and 7 feet height top piece outer dia of 65mm fixed by measure of threading/welding/coupling complete. (excluding foundation). No20600.020600.018.0FalseNoneNoneFalseNoneFalse370800.00
3937468152188None11.8.3Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater Than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater Than IK08. Power Factor greater Than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W System Power consumption. LED Efficiency greater Than1301m/w, nominal CRI greater Than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark/name shall be Engraved/Embossing on the die cast housing/Body part. Warranty of 2 Years against any manufacturing defect LED Streetlight 70W No5992.05992.018.0FalseNoneNoneFalseNoneFalse107856.00
3937469152188None32.051.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 16 Sqmm, 4 Core, (11 GI Strips.4 x 0.8 mm) Km141842.0141842.01.0FalseNoneNoneFalseNoneFalse141842.00
3937470152188None13.5Fixing halogen/metal halide/SVL/IL/LED floodlight fitting over existing pole/ wall ceiling including clA, bolts, nuts and wiring using suitable capacity wires. Each162.0162.018.0FalseNoneNoneFalseNoneFalse2916.00
3937471152188None21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 Sqmm Km20886.020886.00.54FalseNoneNoneFalseNoneFalse11278.440
3937472152188NoneP No.63, I N0.7.20.1Supplying and laying double walled corrugated (DWC) HDPE Pipe including all necessary connecting Socket/Coupling/Tees/Bends/End- caps of same materials in existing trench as per IS 14930 part -II suitable for drawing underground cables.40mmOD/ 32mm ID Mtr75.075.0396.0FalseNoneNoneFalseNoneFalse29700.00
3937473152188None1.1.3Supplying heavy gauge PVC conduit pipe dia mm thick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc., and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws. Mtr106.0106.0180.0FalseNoneNoneFalseNoneFalse19080.00
3937474152188None2.5.2Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage up to 1100 Volts as per IS-694:1990 3C x 1.5 mm2 Mtr72.072.054.0FalseNoneNoneFalseNoneFalse3888.00
3937475152188None2.3.5Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694:confirming to latest amendments. 6 mm2 Mtr92.092.010.0FalseNoneNoneFalseNoneFalse920.00
3937476152188None5.3Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20A single phase Class-1 Accuracy with Temper Proof Energy Meter. Each1380.01380.01.0FalseNoneNoneFalseNoneFalse1380.00
3937477152188None5.44.3Supply and Installation/Fixing/Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65(Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase/ Three Phase Energy Meter in suitable base plate and having a provision for Fuse/ MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.300 mm x 600 mm x 170 mm Each6867.06867.01.0FalseNoneNoneFalseNoneFalse6867.00
3937478152188None5.41.1Supplying and fixing angle iron frame work fabricated out of M.S. angle iron. and M.S. flat with bolts, washers etc., and painted with 2 coats of red oxide and then two coats of approved paint. 40 x 40 x 6 mm Mtr305.0305.010.0FalseNoneNoneFalseNoneFalse3050.00
3937479152188None5.48Supplying and fixing Microprocessor Based Astronomical timer Switch with using necessary bolts, nuts and washers etc. Each4843.04843.02.0FalseNoneNoneFalseNoneFalse9686.00
3937480152188None5.13.1Supply and fixing of 3 pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washersand wiring etc., complete with AC-3 Rating and as per IS-13947. 25 A Each1290.01290.02.0FalseNoneNoneFalseNoneFalse2580.00
3937481152188None5.18.4Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required.confirming to IEC-60898. a) 6-32Amps DP Each739.0739.02.0FalseNoneNoneFalseNoneFalse1478.00
3937482152188None5.7.2Supplying and fixing porcelain fuse channel with cutout on existing panel board using necessary nuts, bolts, washers etc., complete. 32Amps Each241.0241.02.0FalseNoneNoneFalseNoneFalse482.00
3937483152188None51.01GI Grounding pipe, B.Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg No743.0743.02.0FalseNoneNoneFalseNoneFalse1486.00
3937484152188None51.02Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each. No676.0676.02.0FalseNoneNoneFalseNoneFalse1352.00
3937485152188None51.03Good Quality Salt for grounding purposes packed in 50 Kg gunny bag. Bag310.0310.02.0FalseNoneNoneFalseNoneFalse620.00
3937486152188None60.02Alluminium End Terminal (Lug) 16 Sq mm No2.02.0180.0FalseNoneNoneFalseNoneFalse360.00
3937487152188None8.02Guy Wire & GI Wire as per IS-2141 8 SWG GI Wire(4.064 mm Dia), Std Wt: 131 Kg/KM Mtr75040.075040.00.1FalseNoneNoneFalseNoneFalse7504.00
3937488152188None48.05 (Vol.5, It.No.11.2.6)GI Pipe B.Class as per IS-1239, GI Pipe.50 mm Dia Medium Duty GI pipe of 50mm dia, Mtr584.0584.02.0FalseNoneNoneFalseNoneFalse1168.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17256261090000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17256261090000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17256261090000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17256261090000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17256261090000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17256316800000NoneNoneELIGIBILITYAll terms and conditions as per Tender documentNone
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneAchieved in at least two financial years a minimum annual financial turnover of Rs.73.00 Lakh in the past 5 years (2019-20 to 2023-24) and attach duly signed by CA having UDIN NoOthersannual financial turnover
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- annual financial turnover
NoneNoneNoneNoneSatisfactory completed, at least any one year similar Nature of work of Value not less than Rs.36.50 Lakh as Prime ContractorOtherssimilar Nature of work
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- similar Nature of work
NoneNoneNoneNoneExecuted in any one year (for a continuous period of 12 months), the minimum quantities of work as per tender documentOthersminimum quantities of work
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- minimum quantities of work
NoneNoneNoneNoneYear-wise break of quantity in the past five years signed by Executive Officer should be uploadedOthersYear-wise break of quantity
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Year-wise break of quantity
NoneNoneNoneNoneKPWD Registration CertificateOthersKPWD Registration Certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- KPWD Registration Certificate
NoneNoneNoneNoneGST RegistrationOthersGST Registration
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- GST Registration
NoneNoneNoneNoneLiquid Assets and or Availability of Credit Facilities of no less than Rs. 21.90 LakhOthersLiquid Assets
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Liquid Assets
NoneNoneNoneNoneProfit and Loss StatementOthersProfit and Loss Statement
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Profit and Loss Statement
NoneNoneNoneNoneAdhaar CardOthersAdhaar Card
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Adhaar Card
NoneNoneNoneNoneAnnual Turnover duly signed by CA with UDIN No duly signed by CA with UDIN NoOthersAnnual Turnover duly signed by CA with UDIN No
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Annual Turnover duly signed by CA with UDIN No
NoneNoneNoneNonePAN CardOthersPAN Card
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- PAN Card
NoneNoneNoneNoneIT Returns for past 5 years specified in Tender documentOthersIT Returns
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- IT Returns
NoneNoneNoneNoneNot ApplicableOthersNot Applicable
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Not Applicable
NoneNoneNoneNoneNot ApplicableOthersNot Applicable
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Not Applicable
NoneNoneNoneNoneNot ApplicableOthersNot Applicable
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Not Applicable
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1725631913000
version0
createdDateNone
modifiedDateNone
blockNumberDistrict Urban Development Cell Karwar
streetNone
citykarwar
stateKarnataka
pin581301
tenderRecallDTONone