tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1725876792000 | 0 | None | None | Buildings | CONSTRUCTION AND REPAIR OF PRIMARY SCHOOL 2 CLASS ROOMS AND HIGH SCHOOL 2 ROOMS FOR KARNATAKA PUBLIC SCHOOL AT MANGASULI VILLAGE IN KAGWAD TALUKA OF BELAGAVI DIST | 2822130.43 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3943877 | 152677 | None | code01 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates etc complete as per direction of the Engineer incharge of the work. | Cum | 6630.0 | 6630.0 | 9.05 | False | None | None | False | None | False | 60001.5 | 0 | 3943878 | 152677 | None | code02 | Same as above Item For Form Work 70 Percentage etc complete as per direction of the Engineer incharge of the work. | Percentage | 4641.0 | 4641.0 | 9.05 | False | None | None | False | None | False | 42001.05 | 0 | 3943879 | 152677 | None | code03 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates etc complete as per direction of the Engineer incharge of the work. | Cum | 6630.0 | 6630.0 | 49.33 | False | None | None | False | None | False | 327057.9 | 0 | 3943880 | 152677 | None | code04 | Same as above Item For Form Work Lintel & Slab Beam 60 Percentage etc complete as per direction of the Engineer incharge of the work. | Percentage | 3978.0 | 3978.0 | 13.64 | False | None | None | False | None | False | 54259.92 | 0 | 3943881 | 152677 | None | code05 | Same as above Item For Form Work Chajjan 45 Percentage etc complete as per direction of the Engineer incharge of the work. | Percentage | 2983.5 | 2983.5 | 0.61 | False | None | None | False | None | False | 1819.935 | 0 | 3943882 | 152677 | None | code06 | Same as above Item For Form Work Slab 50 Percentage etc complete as per direction of the Engineer incharge of the work. | Percentage | 3315.0 | 3315.0 | 35.08 | False | None | None | False | None | False | 116290.2 | 0 | 3943883 | 152677 | None | code07 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges etc complete as per direction of the Engineer incharge of the work. | Cum | 7969.0 | 7969.0 | 42.3 | False | None | None | False | None | False | 337088.7 | 0 | 3943884 | 152677 | None | code08 | Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification etc complete as per direction of the Engineer incharge of the work. | Kg | 89.45 | 89.45 | 6110.33 | False | None | None | False | None | False | 546569.0185 | 0 | 3943885 | 152677 | None | code09 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & formwork shall be paid separately) etc complete as per direction of the Engineer incharge of the work. | Cum | 6217.0 | 6217.0 | 1.43 | False | None | None | False | None | False | 8890.31 | 0 | 3943886 | 152677 | None | code10 | Providing 12mm cement plaster finished with a floating coat of neat cement of mix 1:4 (1 cement : 4 fine sand ) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete work as per specification etc complete as per direction of the Engineer incharge of the work. | Sqm | 312.0 | 312.0 | 338.8 | False | None | None | False | None | False | 105705.6 | 0 | 3943887 | 152677 | None | code11 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) fnished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fne sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifcations etc complete as per direction of the Engineer incharge of the work. | Sqm | 371.0 | 371.0 | 286.16 | False | None | None | False | None | False | 106165.36 | 0 | 3943888 | 152677 | None | code12 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications etc complete as per direction of the Engineer incharge of the work. | Sqm | 100.0 | 100.0 | 514.48 | False | None | None | False | None | False | 51448.0 | 0 | 3943889 | 152677 | None | code13 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete. Size of Tile 600x600 mm etc complete as per direction of the Engineer incharge of the work. | Sqm | 1145.0 | 1145.0 | 155.6 | False | None | None | False | None | False | 178162.0 | 0 | 3943890 | 152677 | None | code14 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications. etc complete as per direction of the Engineer incharge of the work. | Sqm | 1545.0 | 1545.0 | 67.2 | False | None | None | False | None | False | 103824.0 | 0 | 3943891 | 152677 | None | code15 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. | Sqm | 1650.0 | 1650.0 | 20.06 | False | None | None | False | None | False | 33099.0 | 0 | 3943892 | 152677 | None | code16 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. | Kg | 168.0 | 168.0 | 362.88 | False | None | None | False | None | False | 60963.84 | 0 | 3943893 | 152677 | None | code17 | Providing and fixing in position aluminium windows and ventilators as per approved drawings with sliding shutters using double track window frame section of size 61.85x31.75mm. with 1.2mm thick, bottom section weight 0.695 kg/m, sides and top sections 1.3 mm. thick weight 0.659 kg/m; and shutter comprising top and bottom section of size 40mmx18mm, 1.25mm thick 0.417 kg./m; shutter outer side 40mmx18mm, 1.25mm.thick weight 0.417 kg/m, shutter interlock section 40mmx26.7mm, 1.1mm thick, weight 0.469 kg/m. the shutters mounted on nylon rollers with approved quality of fixtures such as aluminium handles tower bolts etc.; and providing and fixing 5.5mm. thick plain glass for shutters fitted with rubber beading aluminium sections including cutting to required length, joints mitred subdividing the frame tenonned and rivetted in the assembled frame stiffened with end clips at corners angles etc., and fixed to the walls, lintels, floor beams/cills as the case may be with necessary steel screws, raul plugs, or teak wood gatties including cutting masonry or concrete and making good the original surface using cement mortar, aluminium sections pretreated for removal of any Specification No. KBS using aluminium section anodized to 12 - 15 microns.etc complete as per direction of the Engineer incharge of the work. | Sqm | 4266.0 | 4266.0 | 17.28 | False | None | None | False | None | False | 73716.48 | 0 | 3943894 | 152677 | None | code18 | Providing and fixing mosquito mesh to mesh to windows with 7.5 mm to 1.25 mm thick Honne wood petties including labour charges etc complete as per direction of the Engineer incharge of the work. | Sqm | 715.0 | 715.0 | 17.28 | False | None | None | False | None | False | 12355.2 | 0 | 3943895 | 152677 | None | code19 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifcations. Honne wood frames.etc complete as per direction of the Engineer incharge of the work. | Cum | 138074.0 | 138074.0 | 0.68 | False | None | None | False | None | False | 93890.32 | 0 | 3943896 | 152677 | None | code20 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. etc complete as per direction of the Engineer incharge of the work. | Nos | 1016.0 | 1016.0 | 8.0 | False | None | None | False | None | False | 8128.0 | 0 | 3943897 | 152677 | None | code21 | Providing and fxing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifcations. (excluding cost of fxtures) etc complete as per direction of the Engineer incharge of the work. | Sqm | 6897.0 | 6897.0 | 20.16 | False | None | None | False | None | False | 139043.52 | 0 | 3943898 | 152677 | None | code22 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifcations and as per directions of Engineer-in-charge. etc complete as per direction of the Engineer incharge of the work. | Sqm | 137.0 | 137.0 | 338.8 | False | None | None | False | None | False | 46415.6 | 0 | 3943899 | 152677 | None | code23 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifcations etc complete as per direction of the Engineer incharge of the work. | Sqm | 283.0 | 283.0 | 286.16 | False | None | None | False | None | False | 80983.28 | 0 | 3943900 | 152677 | None | code24 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifcations etc complete as per direction of the Engineer incharge of the work. | Sqm | 138.0 | 138.0 | 66.96 | False | None | None | False | None | False | 9240.48 | 0 | 3943901 | 152677 | None | code25 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 ems c/c both horizontally and vertically fixed with chicken mesh for drop chajja, facia, backing to cup boards including cost of all materials, labour, providing and removing form work HOM curing, complete as per specifications.Specification etc complete as per direction of the Engineer incharge of the work. | Sqm | 1066.0 | 1066.0 | 24.19 | False | None | None | False | None | False | 25786.54 | 0 | 3943902 | 152677 | None | code26 | Providing wall black boards in CM 1:3 with two coats of black paint including finishing etc., including cost of materials, labour, HOM complete as per specifications.etc complete as per direction of the Engineer incharge of the work. | Sqm | 772.0 | 772.0 | 12.0 | False | None | None | False | None | False | 9264.0 | 0 | 3943903 | 152677 | None | code27 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers etc complete as per direction of the Engineer incharge of the work. | Sqm | 817.0 | 817.0 | 232.51 | False | None | None | False | None | False | 189960.67 | 0 |
| 1725876792000 | 0 | None | None | Buildings | CONSTRUCTION AND REPAIR OF PRIMARY SCHOOL 2 CLASS ROOMS AND HIGH SCHOOL 2 ROOMS FOR KARNATAKA PUBLIC SCHOOL AT MANGASULI VILLAGE IN KAGWAD TALUKA OF BELAGAVI DIST | 2991235.38 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3943904 | 152678 | None | code01 | Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifcations, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. etc complete as per direction of the Engineer incharge of the work. | Sqm | 91.0 | 91.0 | 171.0 | False | None | None | False | None | False | 15561.0 | 0 | 3943905 | 152678 | None | code02 | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifcations,including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work. In ordinary/soft rock without blasting upto 1.5 m depth etc complete as per direction of the Engineer incharge of the work. | Cum | 299.0 | 299.0 | 99.891 | False | None | None | False | None | False | 29867.409 | 0 | 3943906 | 152678 | None | code03 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & formwork shall be paid separately) (PWDSR 2023-24 Vol-1 P.No.15 I.No. 2.1.3) Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates etc complete as per direction of the Engineer incharge of the work. | Cum | 5989.0 | 5989.0 | 13.86 | False | None | None | False | None | False | 83007.54 | 0 | 3943907 | 152678 | None | code04 | Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticizers laid in fnished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates etc complete as per direction of the Engineer incharge of the work. | Cum | 6287.0 | 6287.0 | 18.4 | False | None | None | False | None | False | 115680.8 | 0 | 3943908 | 152678 | None | code05 | Same as Above Item Form Work Footing 8 Percentage | Percentage | 502.96 | 502.96 | 15.51 | False | None | None | False | None | False | 7800.9096 | 0 | 3943909 | 152678 | None | code06 | Same as Above Item Form Work Column 70 Percentage | Percentage | 4400.9 | 4400.9 | 2.89 | False | None | None | False | None | False | 12718.601 | 0 | 3943910 | 152678 | None | code07 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates etc complete as per direction of the Engineer incharge of the work. | Cum | 6630.0 | 6630.0 | 6.38 | False | None | None | False | None | False | 42299.4 | 0 | 3943911 | 152678 | None | code08 | Same as Above Item Form Work Column 70 Percentage | Percentage | 4641.0 | 4641.0 | 6.38 | False | None | None | False | None | False | 29609.58 | 0 | 3943912 | 152678 | None | code09 | Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confrming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates etc complete as per direction of the Engineer incharge of the work. | Cum | 6630.0 | 6630.0 | 42.97 | False | None | None | False | None | False | 284891.1 | 0 | 3943913 | 152678 | None | code10 | Same as Above Item Form Work Plinth Beam 50 Percentage | Percentage | 3315.0 | 3315.0 | 9.09 | False | None | None | False | None | False | 30133.35 | 0 | 3943914 | 152678 | None | code11 | Same as Above Item form Work Lintel & Slab Beam 60 Percentage | Percentage | 3978.0 | 3978.0 | 11.68 | False | None | None | False | None | False | 46463.04 | 0 | 3943915 | 152678 | None | code12 | Same as Above Item Form Work Chajja 45 Percentage | Percentage | 2983.5 | 2983.5 | 0.46 | False | None | None | False | None | False | 1372.41 | 0 | 3943916 | 152678 | None | code13 | Same as Above Item Form Work Slab 50 Percentage | Percentage | 3315.0 | 3315.0 | 21.74 | False | None | None | False | None | False | 72068.1 | 0 | 3943917 | 152678 | None | code14 | Providing Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand :12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) etc complete as per direction of the Engineer incharge of the work. | Cum | 5611.0 | 5611.0 | 40.91 | False | None | None | False | None | False | 229546.01 | 0 | 3943918 | 152678 | None | code15 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges etc complete as per direction of the Engineer incharge of the work. | Cum | 7969.0 | 7969.0 | 46.44 | False | None | None | False | None | False | 370080.36 | 0 | 3943919 | 152678 | None | code16 | Steel Fabrication Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification etc complete as per direction of the Engineer incharge of the work. | Kg | 89.45 | 89.45 | 5553.87 | False | None | None | False | None | False | 496793.6715 | 0 | 3943920 | 152678 | None | code17 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. etc complete as per direction of the Engineer incharge of the work. | Cum | 266.0 | 266.0 | 136.08 | False | None | None | False | None | False | 36197.28 | 0 | 3943921 | 152678 | None | code18 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & formwork shall be paid separately etc complete as per direction of the Engineer incharge of the work. | Cum | 6217.0 | 6217.0 | 27.49 | False | None | None | False | None | False | 170905.33 | 0 | 3943922 | 152678 | None | code19 | Providing 12mm cement plaster finished with a floating coat of neat cement of mix 1:4 (1 cement : 4 fine sand ) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete work as per specification etc complete as per direction of the Engineer incharge of the work. | Sqm | 312.0 | 312.0 | 176.4 | False | None | None | False | None | False | 55036.8 | 0 | 3943923 | 152678 | None | code20 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) fnished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fne sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifcations etc complete as per direction of the Engineer incharge of the work. | Sqm | 371.0 | 371.0 | 199.69 | False | None | None | False | None | False | 74084.99 | 0 | 3943924 | 152678 | None | code21 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications etc complete as per direction of the Engineer incharge of the work. | Sqm | 100.0 | 100.0 | 332.99 | False | None | None | False | None | False | 33299.0 | 0 | 3943925 | 152678 | None | code22 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc complete. etc complete as per direction of the Engineer incharge of the work. | Sqm | 1145.0 | 1145.0 | 114.0 | False | None | None | False | None | False | 130530.0 | 0 | 3943926 | 152678 | None | code23 | Flooring with 25mm thick polished tandur blue stone slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, , including cost of materials, labour, curing, polishing complete as per specifications.etc complete as per direction of the Engineer incharge of the work. | Sqm | 1545.0 | 1545.0 | 51.23 | False | None | None | False | None | False | 79150.35 | 0 | 3943927 | 152678 | None | code24 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. | Sqm | 1650.0 | 1650.0 | 9.45 | False | None | None | False | None | False | 15592.5 | 0 | 3943928 | 152678 | None | code25 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings /wooden frames with rawl plugs screws etc. | Kg | 168.0 | 168.0 | 241.92 | False | None | None | False | None | False | 40642.56 | 0 | 3943929 | 152678 | None | code26 | Providing and fixing in position aluminium windows and ventilators as per approved drawings with sliding shutters using double track window frame section of size 61.85x31.75mm. with 1.2mm thick, bottom section weight 0.695 kg/m, sides and top sections 1.3 mm. thick weight 0.659 kg/m; and shutter comprising top and bottom section of size 40mmx18mm, 1.25mm thick 0.417 kg./m; shutter outer side 40mmx18mm, 1.25mm.thick weight 0.417 kg/m, shutter interlock section 40mmx26.7mm, 1.1mm thick, weight 0.469 kg/m. the shutters mounted on nylon rollers with approved quality of fixtures such as aluminium handles tower bolts etc.; and providing and fixing 5.5mm. thick plain glass for shutters fitted with rubber beading aluminium sections including cutting to required length, joints mitred subdividing the frame tenonned and rivetted in the assembled frame stiffened with end clips at corners angles etc., and fixed to the walls, lintels, floor beams/cills as the case may be with necessary steel screws, raul plugs, or teak wood gatties including cutting masonry or concrete and making good the original surface using cement mortar, aluminium sections pretreated for removal of any Specification No. KBS using aluminium section anodized to 12 - 15 microns.etc complete as per direction of the Engineer incharge of the work. | Sqm | 4266.0 | 4266.0 | 11.52 | False | None | None | False | None | False | 49144.32 | 0 | 3943930 | 152678 | None | code27 | Providing and fixing 304 - grade stainless steel hand rails of 14-gauge pipes for Ramps or Staircase are made out of stainless steel hallow pipes, using 50mm dia for verticals @1.60 mtr c/c are fixed to the ramps or steps by drilling with bolts and 100mm dia MS base plates 10mm gauge for fixing of Vertical pipes 4 - Nos anchor bolts & 40mm dia pipes are fixed horizontally for 2-rows top, one pipes are fixed with vertical pipes another one are fixed with elbows and 25mm dia pipes are fixed horizontally for 2-rows below top measure @ equal intervals including cutting, welding, bending wherever necessary with suitable caps @ tops, bottoms & corners finishing with mat / shining etc., complete including cost and conveyance of all materials, labour for all items of work, HOM of equipment with all lead and lift, loading and unloading, transportation charges and all other incidental charges etc., complete as per specification and directions of the Engineer-in-charge of the work. Ramps or Staircase for physically challenged etc complete as per direction of the Engineer incharge of the work. | Kg | 565.0 | 565.0 | 185.96 | False | None | None | False | None | False | 105067.4 | 0 | 3943931 | 152678 | None | code28 | Providing Honne wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifcations. --do-- Honne wood frames.etc complete as per direction of the Engineer incharge of the work. | Cum | 138074.0 | 138074.0 | 0.255 | False | None | None | False | None | False | 35208.87 | 0 | 3943932 | 152678 | None | code29 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. etc complete as per direction of the Engineer incharge of the work. | Nos | 1016.0 | 1016.0 | 4.0 | False | None | None | False | None | False | 4064.0 | 0 | 3943933 | 152678 | None | code30 | Providing and fxing in position fully panelled Mathi/Nandi wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifcations. (excluding cost of fxtures) etc complete as per direction of the Engineer incharge of the work. | Sqm | 6897.0 | 6897.0 | 10.08 | False | None | None | False | None | False | 69521.76 | 0 | 3943934 | 152678 | None | code31 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifcations etc complete as per direction of the Engineer incharge of the work. | Sqm | 137.0 | 137.0 | 332.99 | False | None | None | False | None | False | 45619.63 | 0 | 3943935 | 152678 | None | code32 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifcations etc complete as per direction of the Engineer incharge of the work. | Sqm | 283.0 | 283.0 | 199.69 | False | None | None | False | None | False | 56512.27 | 0 | 3943936 | 152678 | None | code33 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifcations etc complete as per direction of the Engineer incharge of the work. | Sqm | 138.0 | 138.0 | 37.08 | False | None | None | False | None | False | 5117.04 | 0 | 3943937 | 152678 | None | code34 | Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6kg per m2 to achieve final DFT (dry film thickness) of 1mm including prime coat of epoxy primer @150 g per m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification & with a 10 years warranty on product & work from certified manufacturers etc complete as per direction of the Engineer incharge of the work. | Sqm | 817.0 | 817.0 | 144.0 | False | None | None | False | None | False | 117648.0 | 0 |
| 1725876792000 | 0 | None | None | Buildings | CONSTRUCTION AND REPAIR OF PRIMARY SCHOOL 2 CLASS ROOMS AND HIGH SCHOOL 2 ROOMS FOR KARNATAKA PUBLIC SCHOOL AT MANGASULI VILLAGE IN KAGWAD TALUKA OF BELAGAVI DIST | 910486.39 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3943938 | 152679 | None | code01 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges etc complete as per direction of the Engineer incharge of the work. | Cum | 7978.0 | 7978.0 | 8.41 | False | None | None | False | None | False | 67094.98 | 0 | 3943939 | 152679 | None | code02 | roviding and fixing Structural Steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications etc complete as per direction of the Engineer incharge of the work. | Kg | 106.0 | 106.0 | 1622.3 | False | None | None | False | None | False | 171963.8 | 0 | 3943940 | 152679 | None | code03 | Providing & fixing corrugated G.S. sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete as per design drawings (up to any pitch in horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required etc complete as per direction of the Engineer incharge of the work. | Sqm | 879.0 | 879.0 | 360.2 | False | None | None | False | None | False | 316615.8 | 0 | 3943941 | 152679 | None | code04 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications etc complete as per direction of the Engineer incharge of the work. | Sqm | 255.0 | 255.0 | 64.08 | False | None | None | False | None | False | 16340.4 | 0 | 3943942 | 152679 | None | code05 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and in cluding water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications etc complete as per direction of the Engineer incharge of the work. | Sqm | 137.0 | 137.0 | 764.85 | False | None | None | False | None | False | 104784.45 | 0 | 3943943 | 152679 | None | code06 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all etc complete as per direction of the Engineer incharge of the work. | Each | 301.0 | 301.0 | 20.0 | False | None | None | False | None | False | 6020.0 | 0 | 3943944 | 152679 | None | code07 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap/basalt crushed graded coarse aggregates and fne aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifcations. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregatesetc complete as per direction of the Engineer incharge of the work. | Cum | 5989.0 | 5989.0 | 7.04 | False | None | None | False | None | False | 42162.56 | 0 | 3943945 | 152679 | None | code08 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc complete etc complete as per direction of the Engineer incharge of the work. | Sqm | 1145.0 | 1145.0 | 75.16 | False | None | None | False | None | False | 86058.2 | 0 | 3943946 | 152679 | None | code09 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifcations etc complete as per direction of the Engineer incharge of the work. | Sqm | 283.0 | 283.0 | 351.4 | False | None | None | False | None | False | 99446.2 | 0 |
| 1725876792000 | 0 | None | None | Buildings | CONSTRUCTION AND REPAIR OF PRIMARY SCHOOL 2 CLASS ROOMS AND HIGH SCHOOL 2 ROOMS FOR KARNATAKA PUBLIC SCHOOL AT MANGASULI VILLAGE IN KAGWAD TALUKA OF BELAGAVI DIST | 81802.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3943947 | 152680 | None | code1 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm required etc complete as per direction of the Engineer incharge of the work. | Mtr | 28.0 | 28.0 | 80.0 | False | None | None | False | None | False | 2240.0 | 0 | 3943948 | 152680 | None | code2 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet etc complete as per direction of the Engineer incharge of the work. Short Point upto 3 mtr from tapping point to out let via switch box | Point | 269.0 | 269.0 | 15.0 | False | None | None | False | None | False | 4035.0 | 0 | 3943949 | 152680 | None | code3 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet etc complete as per direction of the Engineer incharge of the work. Medium point above 3 mtr upto 6 mtr from tapping point to out let via switch box | Point | 279.0 | 279.0 | 5.0 | False | None | None | False | None | False | 1395.0 | 0 | 3943950 | 152680 | None | code4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments etc complete as per direction of the Engineer incharge of the work. 1.5 sqmm | Mtr | 26.0 | 26.0 | 150.0 | False | None | None | False | None | False | 3900.0 | 0 | 3943951 | 152680 | None | code5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments etc complete as per direction of the Engineer incharge of the work.2.5 sqmm | Mtr | 42.0 | 42.0 | 50.0 | False | None | None | False | None | False | 2100.0 | 0 | 3943952 | 152680 | None | code6 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments etc complete as per direction of the Engineer incharge of the work.4 sqmm | Mtr | 63.0 | 63.0 | 20.0 | False | None | None | False | None | False | 1260.0 | 0 | 3943953 | 152680 | None | code8 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. etc complete as per direction of the Engineer incharge of the work. 8 Module | Each | 284.0 | 284.0 | 4.0 | False | None | None | False | None | False | 1136.0 | 0 | 3943954 | 152680 | None | code10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.etc complete as per direction of the Engineer incharge of the work. 6A Two Way Switch | Each | 166.0 | 166.0 | 16.0 | False | None | None | False | None | False | 2656.0 | 0 | 3943955 | 152680 | None | code11 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A.etc complete as per direction of the Engineer incharge of the work. 6Amps 3 way Socket | Each | 171.0 | 171.0 | 4.0 | False | None | None | False | None | False | 684.0 | 0 | 3943956 | 152680 | None | code12 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A.etc complete as per direction of the Engineer incharge of the work. Stepped fan Regulator | Each | 357.0 | 357.0 | 8.0 | False | None | None | False | None | False | 2856.0 | 0 | 3943957 | 152680 | None | code13 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A.etc complete as per direction of the Engineer incharge of the work. 32A Dp switch | Each | 326.0 | 326.0 | 1.0 | False | None | None | False | None | False | 326.0 | 0 | 3943958 | 152680 | None | code14 | Supplying of recess mounting non integrated type LED down light.W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clA, LED of Power/COB with CCT 6500 degree K, CRI 70 efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested b NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition etc complete as per direction of the Engineer incharge of the work. .10-12W | Each | 1269.0 | 1269.0 | 18.0 | False | None | None | False | None | False | 22842.0 | 0 | 3943959 | 152680 | None | code15 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.etc complete as per direction of the Engineer incharge of the work. 56 Sweep (1400 mm) Regular model | Each | 3031.0 | 3031.0 | 12.0 | False | None | None | False | None | False | 36372.0 | 0 |
| 1725876792000 | 0 | None | None | Buildings | CONSTRUCTION AND REPAIR OF PRIMARY SCHOOL 2 CLASS ROOMS AND HIGH SCHOOL 2 ROOMS FOR KARNATAKA PUBLIC SCHOOL AT MANGASULI VILLAGE IN KAGWAD TALUKA OF BELAGAVI DIST | 81802.0 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3943960 | 152681 | None | code1 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm required etc complete as per direction of the Engineer incharge of the work. | Mtr | 28.0 | 28.0 | 80.0 | False | None | None | False | None | False | 2240.0 | 0 | 3943961 | 152681 | None | code2 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet etc complete as per direction of the Engineer incharge of the work. Short Point upto 3 mtr from tapping point to out let via switch box | Point | 269.0 | 269.0 | 15.0 | False | None | None | False | None | False | 4035.0 | 0 | 3943962 | 152681 | None | code3 | Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet etc complete as per direction of the Engineer incharge of the work. Medium point above 3 mtr upto 6 mtr from tapping point to out let via switch box | Point | 279.0 | 279.0 | 5.0 | False | None | None | False | None | False | 1395.0 | 0 | 3943963 | 152681 | None | code4 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments etc complete as per direction of the Engineer incharge of the work. 1.5 sqmm | Mtr | 26.0 | 26.0 | 150.0 | False | None | None | False | None | False | 3900.0 | 0 | 3943964 | 152681 | None | code5 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments etc complete as per direction of the Engineer incharge of the work.2.5 sqmm | Mtr | 42.0 | 42.0 | 50.0 | False | None | None | False | None | False | 2100.0 | 0 | 3943965 | 152681 | None | code6 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments etc complete as per direction of the Engineer incharge of the work.4 sqmm | Mtr | 63.0 | 63.0 | 20.0 | False | None | None | False | None | False | 1260.0 | 0 | 3943966 | 152681 | None | code8 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. etc complete as per direction of the Engineer incharge of the work. 8 Module | Each | 284.0 | 284.0 | 4.0 | False | None | None | False | None | False | 1136.0 | 0 | 3943967 | 152681 | None | code10 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.etc complete as per direction of the Engineer incharge of the work. 6A Two Way Switch | Each | 166.0 | 166.0 | 16.0 | False | None | None | False | None | False | 2656.0 | 0 | 3943968 | 152681 | None | code11 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A.etc complete as per direction of the Engineer incharge of the work. 6Amps 3 way Socket | Each | 171.0 | 171.0 | 4.0 | False | None | None | False | None | False | 684.0 | 0 | 3943969 | 152681 | None | code12 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A.etc complete as per direction of the Engineer incharge of the work. Stepped fan Regulator | Each | 357.0 | 357.0 | 8.0 | False | None | None | False | None | False | 2856.0 | 0 | 3943970 | 152681 | None | code13 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate as per IS 3854 and IS 1293 GROUP A.etc complete as per direction of the Engineer incharge of the work. 32A Dp switch | Each | 326.0 | 326.0 | 1.0 | False | None | None | False | None | False | 326.0 | 0 | 3943971 | 152681 | None | code14 | Supplying of recess mounting non integrated type LED down light.W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clA, LED of Power/COB with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested b NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition etc complete as per direction of the Engineer incharge of the work. .10-12W | Each | 1269.0 | 1269.0 | 18.0 | False | None | None | False | None | False | 22842.0 | 0 | 3943972 | 152681 | None | code15 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.etc complete as per direction of the Engineer incharge of the work. 56 Sweep (1400 mm) Regular model | Each | 3031.0 | 3031.0 | 12.0 | False | None | None | False | None | False | 36372.0 | 0 |
|
|
---|