createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1725521932325
version8
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee2310.00
emd156000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose23-09-2024 16:30:00
tenderQueryClose13-09-2024 17:30:00
technicalBidOpen25-09-2024 11:00:00
publishedDate09-09-2024 15:51:26
publishedByPostDUDC_EE_SMG
publishedByUserKPE11254 - NADAF VAHIDA BEGUM
bidValidityPeriod90
noOfCalls1
preBidMeetingDate17-09-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonPrasad P
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber7892520795
tenderSupplierListNone
tenderSchedule
createdTs1725521932373
version12
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/BD/WORK_INDENT17863
titleConstruction of Building Lighting and Park for the urban local Body TP Thirthahalli Limits under Amrutha Nagarothana (Municipality) Phase-4 Project
descriptionConstruction of Building Lighting and Park for the urban local Body TP Thirthahalli Limits under Amrutha Nagarothana (Municipality) Phase-4 Project.
categoryWORKS
categoryTextWorks
ecv9226233.61
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2202
locationNameDMA District Urban Development Cell Shivamogga
provisionalAmount9412000.0
groupOverheadTotal1407391.57
fileNumberSMGDC-DUDC/PLAN/47/95537/2022
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17255219320001NoneNoneBuildingsConstruction of (Mill keri dinesh layout Anganavadi work) for the urban local Body TP Thirthahalli Limits under Amrutha Nagarothana (Municipality) Phase-4 Project (7.25)1537648.61
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3927557151463NoneI-1.4.1, P-5 Vol-1Earth work excavation by manual means for drains,canals, waste weir,draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 mCum208.32208.3247.15FalseNoneNoneFalseNoneFalse9822.2880
3927558151463NoneI-3.1, P-15 Vol-3Removal of Unserviceable Soil with Disposal upto a suitable distance as directed by the Engineer incharge of workCum35.8435.8447.15FalseNoneNoneFalseNoneFalse1689.8560
3927559151463NoneI-2.1.3, P-15 Vol-1Providing and laying in position plain cement concrete for leveling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labor, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregatesCum6220.486220.486.93FalseNoneNoneFalseNoneFalse43107.92640
3927560151463NoneI-2.2.2.1, P-15 Vol-1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labor, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7031.37031.33.89FalseNoneNoneFalseNoneFalse27351.7570
3927561151463NoneI-5.4, P-17 Vol-2Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum5994.245994.2422.3FalseNoneNoneFalseNoneFalse133671.5520
3927562151463NoneI-1.9, P-7 Vol-1 PWD 2021-22Filling available excavated earth (excluding rock) in trenches, plinth sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.Cum228.48228.4816.61FalseNoneNoneFalseNoneFalse3795.05280
3927563151463NoneI-2.4.3, P-17 Vol-1Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labor, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7382.147382.148.77FalseNoneNoneFalseNoneFalse64741.36780
3927564151463NoneP.No.17 , I. No. 2.5.2, Volume 1 SR 2021-22Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labor, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8313.988313.9812.17FalseNoneNoneFalseNoneFalse101181.13660
3927565151463NoneP.No.13 , I. No. 6.4, Volume 2 SR 2021-22Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labor, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8302.568302.5621.78FalseNoneNoneFalseNoneFalse180829.75680
3927566151463NoneP.No.14 , I. No. 6.15, Volume 2 SR 2021-22Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labor, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm969.92969.9251.69FalseNoneNoneFalseNoneFalse50135.16480
3927567151463NoneP.No. 71, I. No. 9.3,Volume 3 2021-22Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation / Substructure / Superstructure complete as per Drawing and Technical Specifications.t89932.6489932.642.27FalseNoneNoneFalseNoneFalse204147.09280
3927568151463NoneP.No. 41, I. No. 8.2.2 ,Volume 1 2021-22Providing 15 mm cement plaster on the rough side of single or half brick wall of mix :1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labor, curing complete as per specifications and as per directions of Engineer-in-charge...Sqm257.6257.6381.11FalseNoneNoneFalseNoneFalse98173.9360
3927569151463NoneP.No. 46, I.No.8.31 ,Volume 2 2021-22Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade: New work (Two coats applied @1.43 ltr/10 m2 over and including priming coat of exterior primer applied @ 2.20 kg/10 m2) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labor complete as per specifications and as per directions of Engineer-in-charge.Sqm147.84147.84200.93FalseNoneNoneFalseNoneFalse29705.49120
3927570151463NoneP.No. 45, I.No.8.25 ,Volume 2 2021-22Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labor complete as per specifications and as per directions of Engineer-in-charge.Sqm117.6117.6148.68FalseNoneNoneFalseNoneFalse17484.7680
3927571151463NoneP.No. 60, I. No. 9.12.1 ,Volume 2 2021-22Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colors and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete Size of Tile 500x500 mm.Sqm1133.441133.4436.91FalseNoneNoneFalseNoneFalse41835.27040
3927572151463NoneP.No. 65, I. No. 9.38 ,Volume 2 2021-22Providing skirting, dadooing, rises of steps with white glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labor, complete as per specifications.Sqm1090.881090.8831.5FalseNoneNoneFalseNoneFalse34362.720
3927573151463NoneP.No. 101, I. No. 12.21,Volume 2 2021-22Providing and fixing in position fully paneled Matti/Nandi wood shutters for doors with , stiles and rails of 30mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labor, usage charges complete as per specifications. (excluding cost of fixtures)Sqm4323.24323.24.62FalseNoneNoneFalseNoneFalse19973.1840
3927574151463NoneP.No. 100, I. No. 12.12,Volume 2 2021-22Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labor, usage charges complete as per specifications.Sqm84385.2884385.281.26FalseNoneNoneFalseNoneFalse106325.45280
3927575151463NoneP.No. 106, I. No. 12.55.2,Volume 2 2021-22Providing & fixing 30mm thick factory made rigid foam Prelam Paneled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Paneling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 no's of 75mm Aluminum hinges.Sqm3198.723198.724.73FalseNoneNoneFalseNoneFalse15129.94560
3927576151463NoneP.No. 105, I. No. 12.54,Volume 2 2021-22Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No's of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.(P.No. 105, I. No. 12.54,Volume 2 2021-22)Sqm532.0532.04.73FalseNoneNoneFalseNoneFalse2516.360
3927577151463NoneP.No. 91, I. No. 11.44,Volume 2 2021-22Providing and fixing double glazed hermetically sealed glazing in aluminum windows, ventilators and partition etc. with 6 mm thick clear float glass both side, having 12 mm air gap, including providing EPDM gasket, perforated aluminum spacers, desiccants, sealant (Both primary and secondary sealant) etc. as per specifications, drawings and direction of Engineer-in-charge complete including cost of materials, labor, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge..Kg3898.723898.725.85FalseNoneNoneFalseNoneFalse22807.5120
3927578151463NoneP.No. 85, I. No. 11.34A,Volume 2 2021-22Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding.Kg162.4162.4122.85FalseNoneNoneFalseNoneFalse19950.840
3927579151463NoneP.No. 123, I. No. 14.2.1, Volume 2 2021-22Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 liter low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lidEach4509.124509.121.0FalseNoneNoneFalseNoneFalse4509.120
3927580151463NoneP.No. 123, I. No. 14.1.1, Volume 2 2021-22Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 liter low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsEach4755.524755.521.0FalseNoneNoneFalseNoneFalse4755.520
3927581151463NoneP.No. 123, I. No. 14.7.2, Volume 2 2021-22Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapEach2414.722414.721.0FalseNoneNoneFalseNoneFalse2414.720
3927582151463NoneP.No. 123, I. No. 14.10.2.3, Volume 2 2021-22Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink without drain board 470x420 mm bowl depth 178 mm (P.No. 123, I. No. 14.10.2.3 ,Volume 2 2021-22)Each2259.042259.041.0FalseNoneNoneFalseNoneFalse2259.040
3927583151463NoneP.No. 115, I. No. 13.2.2, Volume 2 2021-22Providing and fixing brass bib cock of approved quality : 20 mm nominal bore (P.No. 115, I. No. 13.2.2 ,Volume 2 2021-22)Each386.4386.45.0FalseNoneNoneFalseNoneFalse1932.00
3927584151463NoneP.No. A-16, I. No. 142, Volume 2 2021-22Cudddapah slab 2.5cms thick (P.No. A-16, I. No. 142 ,Volume 2 2021-22)Sqm336.0336.02.0FalseNoneNoneFalseNoneFalse672.00
3927585151463NoneP.No. 134, I-1.7 SOR Code M010G, Volume 5 2021-22Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labor with all lead & lift including encasing the pipe all-round to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3 (P-134 I-1.7 SOR code M010G Vol -5 PWD 2021-21)m441.28441.2820.0FalseNoneNoneFalseNoneFalse8825.60
3927586151463NoneP.No. 11, I-460 MAT Code 3708, Volume 5 2021-22PVC pipe - OD 32mm and 10 Kg/sqcm (P-11 I-460 MAT code 3708 Vol -5 PWD 2021-21)m36.9636.9650.0FalseNoneNoneFalseNoneFalse1848.00
3927587151463NoneP.No. 237, I-2.1 A020A, Volume 5 2021-22Supplying and correction of RCC rings for well staining of 0.3 Mtrs depth using M-20 grade concrete using clean granite or trap or jelly of approved quality 20 mm & down size, well compacted including centering from work & plastering for both faces with C M1:3 proportion as per design using 6.50 mm M.S coil at the rate of 10 Kgs/ring including cost of steel &fabrication bailing out of water erection etc., For 1.80 m dia[clear]rings of staining thickness 0.075 mm upto 18M depth [P-237, I-2.1[A020A]Vol-5, PWD 2021-22]Each2001.442001.448.0FalseNoneNoneFalseNoneFalse16011.520
3927588151463NoneI. No. 13.34, Adendam Volume 5 2021-22KSRB 13-11 : Providing and placing on terrace, polyethylene water storage tanks with manhole lid and suitable locking arrangements, making holes of suitable diameter for inlet, outlet and over flow pipes, including cost of all materials, labor, transport charges, HOM of equipment's and testing complete as per specifications. Specification No.KBS 13.22 (I. No. 13.34, Vol-5, Ist adendam PWD 2022-23)Ltr8.968.96840.0FalseNoneNoneFalseNoneFalse7526.40
3927589151463NoneP.No. 83, I. No. 11.28, Volume 2 2021-22Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labor, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P.No. 83, I. No. 11.28 Vol-2 PWD 2022-23)Kgs560.0560.0105.18FalseNoneNoneFalseNoneFalse58900.80
3927590151463NoneP.No. 82, I. No. 11.25.2, Volume 2 2021-22Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works including cost of materials, labor, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. (P.No. 82, I. No. 11.25.2, Vol-2 PWD 2022-23)Kgs134.4134.4725.74FalseNoneNoneFalseNoneFalse97539.4560
3927591151463NoneP.No. 26, I. No. 7.38, Volume 2 2021-22Providing and fixing precoated galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (P.No. 26, I. No. 7.38, Vol-2 PWD 2022-23)Sqm622.72622.7258.5FalseNoneNoneFalseNoneFalse36429.120
3927592151463NoneP.No. 27, I. No. 7.39.1, Volume 2 2021-22Providing and fixing precoated galvanized steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm) m (P.No. 27, I. No. 7.39.1, Vol-2 PWD 2022-23)Sqm404.32404.328.77FalseNoneNoneFalseNoneFalse3545.88640
3927593151463NoneP No 1,I No 1.2.1, PWD SR 2021-22 Part ISupplying heavy gauge PVC conduit pipe ……….mm ……….. Thick confirming to IS 2509 with suitable size bends, metal junction box adhesive paste etc., and running before concerting the slab. The conduit should be tied to the reinforcement rods by using binding wire and unused ways of junction boxes and pipe ends should be covered using PVC enclosures should be tied to the reinforcement rods by using binding wire and unused ways of junction boxes wire and unused ways of junction boxes and pipe ends should be covered using PVC enclosures run with 18 SWG GL fish wire wherever necessary 19/20 mm dia 2mm thickm61.061.050.0FalseNoneNoneFalseNoneFalse3050.00
3927594151463NoneP No 1,I No 1.2, PWD SR 2021-22 Part ISupplying heavy gauge PVC conduit pipe ……….mm ……….. Thick confirming to IS 2509 with suitable size bends, metal junction box adhesive paste etc., and running before concerting the slab. The conduit should be tied to the reinforcement rods by using binding wire and unused ways of junction boxes and pipe ends should be covered using PVC enclosures should be tied to the reinforcement rods by using binding wire and unused ways of junction boxes wire and unused ways of junction boxes and pipe ends should be covered using PVC enclosures run with 18 SWG GL fish wire wherever necessary 25mm dia 2 mm thickm70.070.020.0FalseNoneNoneFalseNoneFalse1400.00
3927595151463NoneP No 1,I No 1.3.1, PWD SR 2021-22 Part ISupplying heavy gauge PVC conduit pipe ………. dia ……. mm thick with suitable size bends, metal junction boxes adhesive paste etc., by grove cutting in the wall and fixing by using U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire ru through out the conduit wherever necessary 19/20 mm dia 2 mm thickm75.075.0100.0FalseNoneNoneFalseNoneFalse7500.00
3927596151463NoneP No 5,I No 3.4.1, PWD SR 2021-22 Part ISupplying and flush mounting powder coated/galvanized metal box suitable for mounting modular switch plate. The box should be firmly flush mounted after due groove cutting in Brick/Stone/CC wall 1-3 wayNos123.0123.02.0FalseNoneNoneFalseNoneFalse246.00
3927597151463NoneP No 5,I No 3.4.3, PWD SR 2021-22 Part ISupplying and flush mounting powder coated/galvanized metal box suitable for mounting modular switch plate. The box should be firmly flush mounted after due groove cutting in Brick/Stone/CC wall 6 wayNos212.0212.04.0FalseNoneNoneFalseNoneFalse848.00
3927598151463NoneP No 5,I No 3.4.5, PWD SR 2021-22 Part ISupplying and flush mounting powder coated/galvanized metal box suitable for mounting modular switch plate. The box should be firmly flush mounted after due groove cutting in Brick/Stone/CC wall 10-12 wayNos325.0325.01.0FalseNoneNoneFalseNoneFalse325.00
3927599151463NoneP No 2,I No 1.12, PWD SR 2021-22 Part 1Supplying and Fixing metal fan box with round hook On CeilingNos163.0163.02.0FalseNoneNoneFalseNoneFalse326.00
3927600151463NoneP No 22,I No 6.3.1, PWD SR 2021-22 Part 1Supplying capacitor type celling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts, 50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" sweep (1200mm) 48" sweep regular modelNos2085.02085.02.0FalseNoneNoneFalseNoneFalse4170.00
3927601151463NoneP No 46,I No 13.1, PWD SR 2021-22Fixing a ceiling fan of all capacities and all types to the existing 'S' hook with fan regulator to the existing board together with supplying and fixing 5 amps. ceiling rose, necessary length of 23 / 0.0076 inch PVC insulated twin twisted copper wire and wiring. Fixing a ceiling fanNos281.0281.02.0FalseNoneNoneFalseNoneFalse562.00
3927602151463NoneP No 5,I No 3.5.1, PWD SR 2021-22 Part 1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1-3 ModuleNos152.0152.03.0FalseNoneNoneFalseNoneFalse456.00
3927603151463NoneP No 5,I No 3.5.3, PWD SR 2021-22 Part 1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleNos244.0244.05.0FalseNoneNoneFalseNoneFalse1220.00
3927604151463NoneP No 5,I No 3.5.5, PWD SR 2021-22 Part 1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleNos363.0363.01.0FalseNoneNoneFalseNoneFalse363.00
3927605151463NoneP No 3,I No 2.3.2, PWD SR 2021-22 Part 1Wiring for lighting/power circuit using one of PVC insulated 1100 V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS 694:1900 & confirming latest amendment . 1.5mm Sqmmm26.026.0150.0FalseNoneNoneFalseNoneFalse3900.00
3927606151463NoneP No 3,I No 2.3.3, PWD SR 2021-22 Part 1Wiring for lighting/power circuit using one of PVC insulated 1100 V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS 694:1900 & confirming latest amendment . 2.5 Sqmmm40.040.0200.0FalseNoneNoneFalseNoneFalse8000.00
3927607151463NoneP No 3,I No 2.3.4, PWD SR 2021-22 Part 1Wiring for lighting/power circuit using one of PVC insulated 1100 V grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS 694:1900 & confirming latest amendment . 4 Sqmmm59.059.050.0FalseNoneNoneFalseNoneFalse2950.00
3927608151463NoneP No 5,I No 3.6.1, PWD SR 2021-22 Part 1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 6 Amps one wayNos88.088.020.0FalseNoneNoneFalseNoneFalse1760.00
3927609151463NoneP No 5,I No 3.6.3, PWD SR 2021-22 Part 1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 6 Amps 3way socketNos162.0162.08.0FalseNoneNoneFalseNoneFalse1296.00
3927610151463NoneP No 5,I No 3.6.4, PWD SR 2021-22 Part 1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box Stepped Fan RegulatorNos313.0313.02.0FalseNoneNoneFalseNoneFalse626.00
3927611151463NoneP No 5,I No 3.6.8, PWD SR 2021-22 Part 1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 16A One Way SwitchNos249.0249.01.0FalseNoneNoneFalseNoneFalse249.00
3927612151463NoneP No 5,I No 3.6.10, PWD SR 2021-22 Part 1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 32 A DP switchNos375.0375.01.0FalseNoneNoneFalseNoneFalse375.00
3927613151463NoneP No 5,I No 3.6.11, PWD SR 2021-22 Part 1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box 6/16A Universal SocketNos249.0249.01.0FalseNoneNoneFalseNoneFalse249.00
3927614151463NoneP No 13, I No 5.17.4, PWD SR 2021-22 Part 1Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and C curve indicator ON/OFF, energy cross 3 with Short circuit breaking capacity of 10K and complete wiring as required. Confirming to IEC 60898 6-32 Amps DPNos1103.01103.02.0FalseNoneNoneFalseNoneFalse2206.00
3927615151463NoneP No 13, I No 5.18.1, PWD SR 2021-22 Part 1Supplying and fixing regular MCB distribution boards on wall /wood board/flush mounting using required clamps, bolts, nuts etc. with provision for fixing suitable type capacity MCBs single phase/3 phase/ single door with powder coated painting made out of 14 SWG MS enclosure 4 way SP & NNos1104.01104.01.0FalseNoneNoneFalseNoneFalse1104.00
3927616151463NoneP No 5, I No 3.14.6, PWD SR 2021-22 Part 1Supplying and fixing 6 amps lamp holder/Bakelite ceiling rose lamp holderNos63.063.013.0FalseNoneNoneFalseNoneFalse819.00
3927617151463NoneP No 34, I No 11.3, PWD SR 2021-22Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70 percentage lumen maintenance with CRI Greater than 80. Power Input: 220-240V @ 50/60Hz & Power factor Greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x4'- 20/22 w LED light fightingNos740.0740.07.0FalseNoneNoneFalseNoneFalse5180.00
3927618151463NoneSR Item No.11.A,Page No 12 of 27, KPTCL 2021 -2022Grounding of equipment's including cost of 40mm dia 2.5 mm thick, class 'C' G.I pipe of 3 meter length as per specifications, with 50x6 mm GI Flats 3 meter long, salt charcoal, including excavation charges.Nos4950.04950.01.0FalseNoneNoneFalseNoneFalse4950.00
3927619151463NonePWD SR 2022, P No 34 of 47,I No 11.2.2Supplying & fixing retrofit type -PL- LED Lamp 18-20 W LED linear source with CCT 6500 degree K, CRI Greater than 70 percentage. efficiency Greater than 80 lumen per watt, life Greater than25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PFGreater than 0.95, power loss should lesser than 5 percentage of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.Nos691.0691.06.0FalseNoneNoneFalseNoneFalse4146.00
3927620151463NoneP No 22,I No 6.1, PWD SR 2021-22Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply.Nos1542.01542.01.0FalseNoneNoneFalseNoneFalse1542.00
3927621151463NoneP No 46,I No 13.13, PWD SR 2021-22Fixing one exhaust fan after making a suitable notch in the wall and finishing with cement mortar and coloring to match the existing wall or brackets, with bolts and nuts and a 5 A, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame..Nos281.0281.01.0FalseNoneNoneFalseNoneFalse281.00
3927622151463NoneP No 14,I No 5.30, PWD SR 2021-22Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20A single phase Class-1 Accuracy with Temper Proof Energy Meter.Nos1242.01242.01.0FalseNoneNoneFalseNoneFalse1242.00
3927623151463NoneP No 10, I No 5.7.2, PWD SR 2021-22Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers..Nos200.0200.02.0FalseNoneNoneFalseNoneFalse400.00
17255219320000NoneNoneBuildingsConstruction of (Building Lighting and Park ) for the urban local Body TP Thirthahalli Limits under Amrutha Nagarothana (Municipality) Phase-4 Project (Other work)4550435.12
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3927624151464NoneVol-I I.NO1.4.1 Page No 05Earth work excavation by manual means for drains,canals and similar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, re moval of stumps and other deleterious matter, excavated surface lev eled and sides neatly dressed disposing off the excavated stuff or sort ing & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the workCum208.32208.3257.2FalseNoneNoneFalseNoneFalse11915.9040
3927625151464NoneVol-III I.NO 3.1 Page No 15Removal of Unserviceable Soil with Disposal up to a suitable distance as directed by the Engineer in charge of workCum35.8435.8457.2FalseNoneNoneFalseNoneFalse2050.0480
3927626151464NoneI.NO 2.1.2 Vol- Page No15Providing and laying in position plain cement concrete for leveling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labor, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)((Mix 1:4:8( M5) Using 40 mm and down size graded crushed coarse aggregates))Cum5830.725830.7217.84FalseNoneNoneFalseNoneFalse104020.04480
3927627151464NoneI.NO 2.4.2 Vol- Page No 17Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes , labor, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)M20 Design Mix Using 20 mm and down size graded crushed coarse aggregatesCum7218.897218.8923.09FalseNoneNoneFalseNoneFalse166684.17010
3927628151464NoneI.NO 17.5 Vol- Page No 151Providing and fixing factory made precast RCC perforated drain covers, having concrete of strength not less than M-25, of size 1000 x 450x50 mm, reinforced with 8 mm dia four nos longitudinal & 9 nos cross sectional T.M.T. hoop bars, including providing 50 mm dia perforations @ 100 to 125 mm c/c, including providing edge binding with M.S. flats of size 50 mm x 1.6 mm complete, all as per directionof Engineer-in-charge.Each1331.681331.6889.0FalseNoneNoneFalseNoneFalse118519.520
3927629151464NonePWD SR 2021 22 Vol. 2 Page No. 84 Item No. 11.32Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members wherever necessary complete as per Design including cost of material, labor, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)Kg103.04103.041670.95FalseNoneNoneFalseNoneFalse172174.6880
3927630151464NoneI.NO 1.9 Vol- I Page No 07Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.Cum228.48228.4810.64FalseNoneNoneFalseNoneFalse2431.02720
3927631151464NoneVol-III I.NO 2.1 A (i)Page No 07Cutting of Trees, excluding removal of stumps and roots of trees(Girth from 300 mm to 600 mm))Cum525.28525.2810.0FalseNoneNoneFalseNoneFalse5252.80
3927632151464NoneVol-III I.NO 2.2 B (i)Page No 07Removal of stumps and roots including backfilling with suitable material to required compaction(Girth from 300 mm to 600 mm))Cum260.96260.9610.0FalseNoneNoneFalseNoneFalse2609.60
3927633151464NoneI.NO1.16 Vol- I Page No 9Earth work excavation for FOUNDATION by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labor, blasting materials, tools, usage of Machinery & all other appurtenances required to complete the work((In Hard Rock ( requiring blasting) Depth upto 1.50m))Cum469.28469.28115.9FalseNoneNoneFalseNoneFalse54389.5520
3927634151464NoneI.NO5.4 VolI- II Page No 09Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)Cum5994.245994.24135.0FalseNoneNoneFalseNoneFalse809222.40
3927635151464NoneI.NO 2.2.1.1 Vol- I Page No 15Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labor, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)Cum7188.657188.656.78FalseNoneNoneFalseNoneFalse48739.0470
3927636151464NoneI.NO 2.2.1.1 Vol- I Page No 15Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labor, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately)Cum11315.4711315.471.06FalseNoneNoneFalseNoneFalse11994.39820
3927637151464NoneI.NO 11.16.1 VolI- Page No 81Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labor, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-ChargeKg122.08122.082511.3FalseNoneNoneFalseNoneFalse306579.5040
3927638151464NoneI.NO 11.2 VolI- Page No 75Providing and fixing Structural Steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.Kg113.12113.125623.24FalseNoneNoneFalseNoneFalse636100.90880
3927639151464NoneI.NO 8.41 VolI- Page No 48Painting with synthetic enamel paint of approved brand and manufacture of required color to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labor complete as per specifications and as per directions of Engineer-in-charge.Sqm145.6145.6551.66FalseNoneNoneFalseNoneFalse80321.6960
3927640151464NoneI.NO 8.25 Vol- II Page No 45Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labor complete as per specifications and as per directions of Engineer-in-charge.Sqm117.6117.66.0FalseNoneNoneFalseNoneFalse705.60
3927641151464NonePwd SR 2021-22 Item-2.4.3, Page-17 Vol-1Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum7382.147382.142.81FalseNoneNoneFalseNoneFalse20743.81340
3927642151464NoneP.No.17 , I.No. 2.5.2, Volume 1 SR 2021-22Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum8313.988313.9828.09FalseNoneNoneFalseNoneFalse233539.69820
3927643151464NoneP.No.13 , I.No. 6.4, Volume 2 SR 2021-22Providing Brick work with common burnt clay modular bricks of class designation 3.5 in foundation and plinth in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum8302.568302.5615.93FalseNoneNoneFalseNoneFalse132259.78080
3927644151464NoneP.No.14 , I.No. 6.15, Volume 2 SR 2021-22Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:4 (1 cement :4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Sqm969.92969.9216.5FalseNoneNoneFalseNoneFalse16003.680
3927645151464NoneP.No. 71, I.No. 9.3,Volume 3 2021-22Supplying, Fitting and Placing TMT Fe 500 & above Reinforcement in Foundation / Substructure / Superstructure complete as per Drawing and Technical Specifications.Tonne89932.6489932.642.78FalseNoneNoneFalseNoneFalse250012.73920
3927646151464NonePwd Part I Volume 6 Item No.4.5.1 Pg No.8Fabrication, Supplying, Erection, Testing and Commissioning of...... ms long Polygon high mast with Single/Multiple telescopic sections having, (minimum overlap distance of 1.5 times of top section) thickness as per BSEN 10025 grades 355 JO/ASTM A572-50 steel sheet plate for shaft suitable to withstand a wind velocity of 47 m/s as per IS 875 part 3(as per GA Drawing). Base plate as per IS 2062/ASTM A572-50. The mast shall be Galvanized in single Hot-dip as per BSEN ISO 1461/ASTM A123 with an average 70 microns as per IS 2629, and welded as per BS 5135 Single L-Seam joint The mast shall have 2 Way head frame with die cast LM-6 pulleys, stainless steel axle, Phosphorus Bronze bearing bush press-fitted with separate guides for 2 runs of 5 mm dia, stainless steel wire rope of AISI 304grade 7/19-core, (Factor of Safety as per TR no-7). 2.5 mm2 EPR insulated PCP sheathed trailing power cable housed inside the bottom shaft of mast with door having locking arrangement The mast shall have manual/power tool (Suitable reversible geared motor operating on 230/415V, 50Hz, shall be provide above 15 Mtr mast) The mast shall have lantern of 2 segments, suitable dia with max load carrying capacity as per IS 1239. The mast shall be erected on existing RCC footing. The mast shall be supplied with 3 mm thick template, lightning arrester of 1.2m length galvanized pipe with top arrow fitted on top of the head frame cover and GLS type aviation twin l A fitting with wiring complete. (excluding foundation) as per technical data. m/12.5 m - Top 100 mm and Bottom 310 mm diaEach116177.0116177.03.0FalseNoneNoneFalseNoneFalse348531.00
3927647151464NonePwd Part I Volume 6 Item No.11.9.2 Pg No.37Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT greater than5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire greater than IK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with W SystemPower consumption. LED Efficiency greater than1301m/w, nominal CRI greater than75. Luminaire manufacturer should have in- house facility accredited by NABL / CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark / name shall be Engraved / Embossing on the die cast housing / Body part Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above LED Floodlight 100WEach8172.08172.012.0FalseNoneNoneFalseNoneFalse98064.00
3927648151464NonePwd Part I Volume 6 Item No.2.3.4 Pg No.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments.4 mm2m59.059.0560.0FalseNoneNoneFalseNoneFalse33040.00
3927649151464NonePwd Part I Volume 6 Item No.5.44.3 Pg No.16Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility.300 mm x 600 mm x 170 mmMtr6170.06170.05.0FalseNoneNoneFalseNoneFalse30850.00
3927650151464NonePwd Part I Volume 6 Item No.5.48 Pg No.16Supplying and fixing Microprocessor Based Astronomical timer Switch with using necessary bolts, nuts and washers.Each4352.04352.05.0FalseNoneNoneFalseNoneFalse21760.00
3927651151464NoneBescom Part III Volume 6 Item No.56.05 Pg No.18LT Single Phase 5-30 Amps, DLMS Complaint Static Energy Meter, 1.0 Accuracy Class (Used for LT-2, LT-3 & LT-5 Installations)No934.0934.05.0FalseNoneNoneFalseNoneFalse4670.00
3927652151464NonePwd Part I Volume 6 Item No.1.1.2 Pg No.1Supplying heavy gauge PVC conduit pipe ....... dia mmthick confirming to IS 2509 with suitable size bends, junction boxes, adhesive paste etc , and fixing using inverted wood plugs in case of RCC ceiling and RCC wall/ stone structure or rawl plugs in case of brick walls and cement plastering the damaged portion using heavy gauge saddles at an interval of 700mm using NF screws.25 mm dia 2 mm thickMtr65.065.080.0FalseNoneNoneFalseNoneFalse5200.00
3927653151464NonePwd Part I Volume 6 Item No.5.17.6 Pg No.13Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 50-63 A DPEach1376.01376.05.0FalseNoneNoneFalseNoneFalse6880.00
3927654151464NonePwd Part I Volume 6 Item No.5.9.3 Pg No.11Supplying and fixing HRC fuse units base on existing switch / panel board.100 to 300 AEach459.0459.05.0FalseNoneNoneFalseNoneFalse2295.00
3927655151464NonePwd Part I Volume 6 Item No.5.20.2 Pg No.13Supplying, fixing and wiring Earth Leakage Miniature CircuitBreaker (ELMCB) 240/450V upto 300mA sensitivity on existing wood/panel board.32-40 A 2 poleEach2653.02653.07.0FalseNoneNoneFalseNoneFalse18571.00
3927656151464NoneP.No 40, Sl no 6.1Supplying, fixing, wiring earth electrode for grounding conduits, C. I .cut outs and other equipment's on the meter board using 40mm dia 2.90mm thick GI pipe 2.5 mtr long buried in a pit the pit should be filled with equal proportion of salt and charcoal 150mm alrond the pipe to complete depth. the connection from the pipe to the conduit etc., is to be established through GI wire of size as per ISI specification 7.3.3.of IS 732 using 12mm dia bolts ,nuts , washers and checknuts etc., the pipe shall have 16 through holes of 12 mm dia.(P.No 40, Sl no 6.1 )Each2999.72999.75.0FalseNoneNoneFalseNoneFalse14998.50
3927657151464NoneP. No.40, Sl no 6.3.1supplying and running of 25x3mm GI/Copper strips for grounding connections, using necessary fixing materials as required. (P. No.40, Sl no 6.3.1 )Mtr75.075.025.0FalseNoneNoneFalseNoneFalse1875.00
3927658151464NoneP.No 40 ,S.No 6.4.4Supplying of 4 core 16sqmm class A LT UG cable having aluminum conductor PVC insulated, sheathed .galvanized, steel wire/steel tap armored cable with PVC other sheathing 1.1 KV class (P.No 40 ,S.No 6.4.4 )Mtr150.0150.0900.0FalseNoneNoneFalseNoneFalse135000.00
3927659151464NoneP. No .41, Sl No .6.6.1Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc.,complete.(As per Civil SR KSRB I-2, P-7)Mtr76.076.0840.0FalseNoneNoneFalseNoneFalse63840.00
3927660151464NoneP. No .41, Sl No .6.6.3Digging of trench of 0.6m deep x 0.50 mtr wide refilling the trench to the required ground level and consolidating etc.,complete.(As per Civil SR KSRB I-2, P-7)Cutting road surfaceMtr82.082.0840.0FalseNoneNoneFalseNoneFalse68880.00
3927661151464NoneP.No 41 ,S.No 6.5.1Labor charges for laying of 1.1 KV class UG cable in existing trench GI pipe / stoneware pipe / on wall / on pole as required. In existing trench/duct.6 sqmm to 16 sqmmMtr11.8811.88900.0FalseNoneNoneFalseNoneFalse10692.00
3927662151464NoneP.No 42 ,S.No 6.9.2Supplying and fixing of class A (medium duty) GI pipe of wall thickness not less than 3.25mm on pole/wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV.50mmMtr380.0380.090.0FalseNoneNoneFalseNoneFalse34200.00
3927663151464NoneP.No 41 ,S.No 6.7Providing and filling sand in excavated trench to cover already laid UG cable to a depth of 150mm all-round the cable.Mtr100.0100.0810.0FalseNoneNoneFalseNoneFalse81000.00
3927664151464NoneP.No.42,It.No.6.11.1Supplying and fixing of heavy duty cable glands suitable for UG cable of 1.1 KV class (metal only) 19/20mmNo68.068.010.0FalseNoneNoneFalseNoneFalse680.00
3927665151464NonePwd Part I Volume 6 Item No.4.1.2 Pg No.7Fabricating, supplying and erecting Swaged tubular Pole of height ...m having three sections, and providing two coats of red oxide paint and finished with two coats of enamelled paint of approved quality and colour and M.S. base plate of suitable size welded at the bottom of the Pole(as per IS) and 40 mm dia GI/flexible PVC pipe of 1m length fitted to the heavy gauge polycarbonate control box including 5 Way connector of size 167 x 125 x 82 mm for 7.5M Pole/ 200 x 160 x 98 mm for remaining length of Pole with front opening cover, with locking arrangements and suitable capacity MCB/DP switch, The Pole shall be erected in cement concrete work (1:2:4) including excavation and refilling of planting depth of the Pole to the ground level and the coping CC shall be upto 0.6m above ground level as per IS2713-7.Erection of heavy duty Pole on Footpath/median 10m (5m Hb,165.1 mm dia 4.85 mm thick x 3m Hm, 139.7 mm dia 4.50 mm thick x 2m Ht,114.3 mm dia 3.65 mm thick) as per IS 410 SP 47Each17163.017163.014.0FalseNoneNoneFalseNoneFalse240282.00
3927666151464NonePwd Part I Volume 6 Item No.11.8.4 Pg No.36Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT greater than 5500K, IP66 optical and electrical compartment & impact resistance of complete luminaire greater thanIK08. Power Factor greater than 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mounting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED Efficiencyg reater than1301m/w, nominal CRI greater than 75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008. Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect LED Streetlight 90 WNo7777.07777.014.0FalseNoneNoneFalseNoneFalse108878.00
3927667151464NonePwd Part I Volume 6 Item No.5.9.3 Pg No.11Supplying and fixing HRC fuse units base on existing switch / panel board. 100 to 300 AEach459.0459.02.0FalseNoneNoneFalseNoneFalse918.00
3927668151464NonePwd Part I Volume 6 Item No.5.14.7 Pg No.12Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts, necessary phase separators, handle and wiring complete. Protection of Overload and Short circuit in Thermal Magnetic Release. Micro processor release shall have Earth Fault as per IS-13947. (Icu=100% lcs). In 4P MCCB, all Poles should have protection for Short-Cicrcuit/Over Load. For Microprocessor MCCBS Facility for segregating Priority and Non-Priority loads must be available in the MCCB. MCCB shall be provided with double insulation (insulation between front cover and internal power circuits to avoid any accidental contact with live current carrying path with the front cover open). Multi-pole breakers shall be designed to break all the poles simultaneously and they shall have a single mechanism. 100 A 25 kAEach8265.08265.04.0FalseNoneNoneFalseNoneFalse33060.00
17255219320001NoneNoneBuildingsConstruction of (Building Lighting and Park ) for the urban local Body TP Thirthahalli Limits under Amrutha Nagarothana (Municipality) Phase-4 Project PK1730758.31
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3927669151465NoneVol. 2- Page No. 174 - Item No.20.12Raking out joints in lime or cement mortar and preparing the surface forre-pointing or replastering, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.Sqm42.5642.5682.99FalseNoneNoneFalseNoneFalse3532.05440
3927670151465NoneVol. 1 - Page No. 15 - Item No. 2.2.1.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately)-M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregates M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum11315.4711315.470.59FalseNoneNoneFalseNoneFalse6676.12730
3927671151465NoneVol. 1 Item No. 2.2.1.1Providing and laying in position Reinforced cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement to be paid separately)-M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum9984.249984.247.87FalseNoneNoneFalseNoneFalse78575.96880
3927672151465NoneVol. 1 Item No. 2.5.1Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) M20 Design Mix Using 20 mm nominal size graded crushed coarse aggregatesCum10385.7610385.7627.93FalseNoneNoneFalseNoneFalse290074.27680
3927673151465NoneVol. 1 Item No. 2.1.4Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 20 mm nominal size graded crushed coarse aggregatesCum6220.486220.489.04FalseNoneNoneFalseNoneFalse56233.13920
3927674151465NoneVol. 2 - Item No. 11.32Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)Kg103.04103.043365.6FalseNoneNoneFalseNoneFalse346791.4240
3927675151465None2021-22 - Vol. 2 - Page No. 14 - Item No.6.8Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work.Cum7492.87492.84.86FalseNoneNoneFalseNoneFalse36415.0080
3927676151465NoneVol. 2 - Item No.6.33Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1188.321188.3217.43FalseNoneNoneFalseNoneFalse20712.41760
3927677151465NoneVol. 2 - Item No.6.34Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.Sqm1052.81052.824.63FalseNoneNoneFalseNoneFalse25930.4640
3927678151465NoneVol. 2 - - Item No.8.1.1Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm238.56238.56277.26FalseNoneNoneFalseNoneFalse66143.14560
3927679151465NoneVol. 2 - Item No.8.1.2Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.Sqm277.76277.76240.28FalseNoneNoneFalseNoneFalse66740.17280
3927680151465NoneVol. 2 - - Item No.9.12.2Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.:Size of Tile 600x600 mmSqm1133.441133.44190.58FalseNoneNoneFalseNoneFalse216010.99520
3927681151465NoneVol. 2 Item No.9.7.1Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding for Bathrooms: Toilet: Chemically exposed areas and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) with Acid and alkali resistant tileSqm1187.21187.222.76FalseNoneNoneFalseNoneFalse27020.6720
3927682151465NoneVol. 2 - - Item No. 8.51Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge.Sqm92.9692.96554.51FalseNoneNoneFalseNoneFalse51547.24960
3927683151465NoneVol. 2 Item No. 8.25Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade :New work (two coats) over and including water thinnable priming coat with cement primer after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm117.6117.6277.26FalseNoneNoneFalseNoneFalse32605.7760
3927684151465NoneVol. 2 Item No. 11.34AProviding and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by weldingKg162.4162.4272.16FalseNoneNoneFalseNoneFalse44198.7840
3927685151465NoneVol. 2 Item No. 8.40Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm100.8100.812.96FalseNoneNoneFalseNoneFalse1306.3680
3927686151465NoneVol. 2 Item No. 8.32Finishing walls with 100percenatage Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied at 1.43 litre/ 10 m2. Over and including priming coat of exterior primer applied at 0.90 litre/10 m2 with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sqm125.44125.44240.28FalseNoneNoneFalseNoneFalse30140.72320
3927687151465NoneVol. 2 Item No.12.84PProviding & fixing of 2 track x 2 panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6 PHR with TPE (Thermo Plastic Elastomer) and lead free, gaskets grey color having isolated drainage and reinforced with Galvanized Iron profile through out the window frame. The outer frame having an overall size of 44mm width x 40mmheight with reinforcement of 1mm thickness and Sash with overall size of 27mm X 53mm with UPVC honeycomb structure inside in lieu of GI reinforcement. Coextruded Glazing bead for fixing of glass shall be of size 9.5mm x 21.5mm. Windows shall be provided with 5mm plain float glass, standard hardware and single point locking system with Crescent Locks. Wall thickness of frame & sash shall be of 2 mm.Maximum possible size 1219mm x 1219mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made)Sqm4607.684607.688.64FalseNoneNoneFalseNoneFalse39810.35520
3927688151465NoneVol. 2 Item No.12.55Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75mm Aluminium hinges. with one side prelamSqm3198.723198.725.04FalseNoneNoneFalseNoneFalse16121.54880
3927689151465NoneVol. V Item No. 1.1 M010ASupplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 25mm dia, 10 kg/sqcm & class 5Mtr52.6452.6425.0FalseNoneNoneFalseNoneFalse1316.00
3927690151465NoneVol. V item No. 1.1 M010BSupplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 32mm dia., 10 kg/sqcm & class 5Mtr71.6871.6825.0FalseNoneNoneFalseNoneFalse1792.00
3927691151465NoneVol. 2 Item No. 13.1.1Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :25 to 40 mm nominal boreNos527.52527.525.0FalseNoneNoneFalseNoneFalse2637.60
3927692151465NoneVol. 2 - Item No. 13.18.1Providing and fixing PTMT stop cock of approved quality and colour 15 mm nominal bore, 86 mm long, weighing not less than 88 gNos159.04159.042.0FalseNoneNoneFalseNoneFalse318.080
3927693151465NoneVol. 2 - Item No. 13.18.2Providing and fixing PTMT stop cock of approved quality and colour 20 mm nominal bore, 86 mm long,Nos169.12169.122.0FalseNoneNoneFalseNoneFalse338.240
3927694151465NoneVol. 2 - No. 13.4.1Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :25 mm nominal boreNos591.36591.362.0FalseNoneNoneFalseNoneFalse1182.720
3927695151465NoneVol. 2 No. 13.4.1Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 32 mm nominal boreNos646.24646.242.0FalseNoneNoneFalseNoneFalse1292.480
3927696151465NoneVol. 2 - Item No. 13.17.1Providing and fixing PTMT bib cock of approved quality and colour. 15mm nominal bore, 86 mm long, weighing not less than 88 gNos165.76165.768.0FalseNoneNoneFalseNoneFalse1326.080
3927697151465NoneVol. 2 Item No. 13.5.3Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 25 mm nominal boreNos430.08430.084.0FalseNoneNoneFalseNoneFalse1720.320
3927698151465NoneVol. 2 - Item No. 13.11.2Providing and fixing G.I. Union in existing G.I. pipe line, cutting and threading the pipe and making long screws, including excavation, refilling the earth or cutting of wall and making good the same complete wherever required : 20 mm nominal boreSet489.44489.442.0FalseNoneNoneFalseNoneFalse978.880
3927699151465NoneVol. 2 - Item No. 13.6.1.1Providing and fixing gun metal non- return valve of approved quality (screwed end) : 25 mm nominal bore HorizontalNos552.16552.162.0FalseNoneNoneFalseNoneFalse1104.320
3927700151465NoneVol.2 - Item No. 13.34Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank.Ltr8.968.961000.0FalseNoneNoneFalseNoneFalse8960.00
3927701151465NoneVol. 2 - Item No. 14.7AProviding and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixerUnit4030.884030.882.0FalseNoneNoneFalseNoneFalse8061.760
3927702151465NoneIt No 11.50.2KSRB 12-8.1 : Constructing brick masonary inspection chambr 600 X 600mm, and 450mm depth, (clear inside dimsition) for single pipe line using table moulded non-modular bricks of class designation 50 in cement mortar 1:5, C.I cover with frame (light dur\ty) 600 X 600mm intrnal dimntion, total wt of cover with frame to be not less than 38kg ( wt of cover 23kg wt of frame 15kg ) R.C.C. top slab with cement concteate 1:2:4 mix 20mm and down size granite metal, foundation concrate 1:5:10 40mm and down size granite metal, inside plastering 12mm thick with cement mortar 1:3, finish smooth with a flooting coat of cement on walls and bed concrate complete as per standard design including cost of all materials, labourcharges, curring complete as per specifications.No9791.049791.044.0FalseNoneNoneFalseNoneFalse39164.160
3927703151465NoneVol. 2 No. 14.3.1Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lidEach5605.65605.62.0FalseNoneNoneFalseNoneFalse11211.20
3927704151465NoneVol. 2 - Item No. 14.1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsEach4755.524755.522.0FalseNoneNoneFalseNoneFalse9511.040
3927705151465NoneVol. 2 Item No. 14.5.1Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required :Single half stall urinal with 5 litre P.V.C. automatic flushing cisternEach7423.367423.365.0FalseNoneNoneFalseNoneFalse37116.80
3927706151465NoneIt No 12.113.2 1Providing and fixing CI Nahani trap of approved make conforming to ISI specification and construction of Cistern in M-15 as per directions (Rate is inclusive of cost of materials and fixtures and conveyance of materials to work spot)Unit319.2319.210.0FalseNoneNoneFalseNoneFalse3192.00
3927707151465NoneVol. 2 Item No. 13.10.4Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) : 40 mm nominal boreUnit450.24450.248.0FalseNoneNoneFalseNoneFalse3601.920
3927708151465NoneVol. V - No. 1.1 M010ASupplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 90mm dia., 6 kg/sqcm & class 3Rmtr334.88334.885.0FalseNoneNoneFalseNoneFalse1674.40
3927709151465NoneVol. V - Item No. 1.1 M010ASupplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 110mm dia., 6 kg/sqcm & class 3Rmtr441.28441.2840.0FalseNoneNoneFalseNoneFalse17651.20
3927710151465NoneVol. 2 - Item No. 14.31Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.Each1087.521087.522.0FalseNoneNoneFalseNoneFalse2175.040
3927711151465NoneVol. 2 Item No.14.7.2Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tapNos.2414.722414.722.0FalseNoneNoneFalseNoneFalse4829.440
3927712151465NoneVol. 2 - Item No.13.16Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931Nos.552.16552.164.0FalseNoneNoneFalseNoneFalse2208.640
3927713151465NoneVol. 5 - Item No. P440ASupply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments 2 HP, Size 65x50 Head 13M, Discharge 462 LPMNos.17276.017276.01.0FalseNoneNoneFalseNoneFalse17276.00
3927714151465NoneChapter - 1 Item No.1.1.1Concealed Conduit System Supplying Heavy Gauge PVC Conduit pipe 19/20 mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipes ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 19/20 mm dia 2 mm thickMtr68.068.035.0FalseNoneNoneFalseNoneFalse2380.00
3927715151465NoneItem No.1.2.2Concealed Conduit System Supplying Heavy Gauge PVC Conduit pipe 25 mm dia 2mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipes ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25 mm dia 2 mm thickMtr70.070.025.0FalseNoneNoneFalseNoneFalse1750.00
3927716151465NoneItem No.1.3.1Concealed conduit System, Supplying Heavy Gauge PVC Conduit Pipe 19/20mm dia 2mm thick with suitable size bends, metal/PVE junction boxes adhesive paste etc., by groove cutting in the wall & fixing by using U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run through out the conduit wherever necessary.19/20 mm dia 2 mm thickMtr75.075.015.0FalseNoneNoneFalseNoneFalse1125.00
3927717151465NoneItem No.1.3.2Concealed conduit System, Supplying Heavy Gauge PVC Conduit Pipe 25mm dia 2mm thick with suitable size bends, metal/PVE junction boxes adhesive paste etc., by groove cutting in the wall & fixing by using U or J hooks and cement plastering up to the wall surface and run with 18 SWG GI fish wire run through out the conduit wherever necessary.25 mm dia 2 mm thickMtr80.080.015.0FalseNoneNoneFalseNoneFalse1200.00
3927718151465NoneItem No.1.1.3Concealed conduit System, Supplying Heavy Gauge PVC Conduit Pipe 32mm dia 2.5 mm thick with Confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosure. Run with 18SWG GI fish wire wherever necessary. 32 mm dia 2.5 mm thickMtr100.0100.015.0FalseNoneNoneFalseNoneFalse1500.00
3927719151465NoneChapter - 3, Item No.3.3.1Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.1-3 WayEach91.091.05.0FalseNoneNoneFalseNoneFalse455.00
3927720151465NoneItem No.3.3.2Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.4-5 WayEach122.0122.05.0FalseNoneNoneFalseNoneFalse610.00
3927721151465NoneItem No.3.3.4Supplying and fixing surface/flush mounting unbreakable PVC modular box suitable for mounting modular switch plates with due groove cutting in Brick/C.C wall, including necessary rawl plugs, Machine/NF screws etc., complete.8 WayEach195.0195.05.0FalseNoneNoneFalseNoneFalse975.00
3927722151465NoneItem No.3.5.1Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.1 to 3 ModuleEach152.0152.05.0FalseNoneNoneFalseNoneFalse760.00
3927723151465NoneItem No.3.5.2Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.4 ModuleEach175.0175.05.0FalseNoneNoneFalseNoneFalse875.00
3927724151465NoneItem No.3.5.4Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box.8 ModuleEach302.0302.02.0FalseNoneNoneFalseNoneFalse604.00
3927725151465NoneItem No.3.6.1Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A One Way SwitchEach88.088.02.0FalseNoneNoneFalseNoneFalse176.00
3927726151465NoneItem No.3.6.2Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Two Way SwitchEach152.0152.02.0FalseNoneNoneFalseNoneFalse304.00
3927727151465NoneItem No.3.6.3Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6A Three Way socketEach162.0162.04.0FalseNoneNoneFalseNoneFalse648.00
3927728151465NoneItem No.3.6.10Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.32A DP SwitchEach375.0375.04.0FalseNoneNoneFalseNoneFalse1500.00
3927729151465NoneItem No.3.6.11Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293.6/16A Universal SocketEach249.0249.02.0FalseNoneNoneFalseNoneFalse498.00
3927730151465NoneItem No.2.1.1Point Wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC conduit / casing capping using 1100V grade, COPPER conductor flexible multi strand FRLS PVC insulated to 2X1.5 Sqmm cabale confirming to the GTP with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point upto 3 Mtr from tapping point to outlet via switch.Nos276.0276.05.0FalseNoneNoneFalseNoneFalse1380.00
3927731151465NoneItem No.2.1.2Point Wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC conduit / casing capping using 1100V grade, COPPER conductor flexible multi strand FRLS PVC insulated to 2X1.5 Sqmm cabale confirming to the GTP with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr upto 6Mtr from tapping point to outlet via switch.Nos386.0386.05.0FalseNoneNoneFalseNoneFalse1930.00
3927732151465NoneItem No.2.1.3Point Wiring using Copper wire with switch. Supplying and wiring adopting loop system in existing PVC conduit / casing capping using 1100V grade, COPPER conductor flexible multi strand FRLS PVC insulated to 2X1.5 Sqmm cabale confirming to the GTP with a 6 Amps flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to outlet via switch.Nos567.0567.04.0FalseNoneNoneFalseNoneFalse2268.00
3927733151465NoneItem No.3.1.2Supplying 6A flush type socket and 6Amps flush type SP switch either surface / flush mounting in existing gang box or in a 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required. as per IS 1293 and IS 3654 6 Amps 3/5 wayEach143.0143.05.0FalseNoneNoneFalseNoneFalse715.00
3927734151465NoneItem No.2.3.1Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTP 1 mm2Mtr18.018.04.0FalseNoneNoneFalseNoneFalse72.00
3927735151465NoneItem No.2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTP 1.5 mm2Mtr26.026.05.0FalseNoneNoneFalseNoneFalse130.00
3927736151465NoneItem No.2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTP 2.5 mm2Mtr40.040.05.0FalseNoneNoneFalseNoneFalse200.00
3927737151465NoneItem No.2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100v grade, multistrand Copper with low conductor resistance single core wire in open or concealed system of wiring with specified IS-694:1990 & confirming to the attached GTP 4 mm2Mtr59.059.04.0FalseNoneNoneFalseNoneFalse236.00
3927738151465NoneItem No.6.3.1Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc, for operation on 230 V, 50 cycles. Single phase AC supply conforming to ISS-374- 1979 and with double ball bearing system.48" Sweep (1200 mm) Regular modelEach2085.02085.04.0FalseNoneNoneFalseNoneFalse8340.00
3927739151465None11, Item No.11.3.2Supplying of .4'.feet -PVC Batten with integrated LED tube 20/22 W with high quality diffuser with Life of 25000 burning hours & 70 Percentage lumen maintenance with CRI Greater than 80. Power Input: 220-240V@ 50/60Hz & Power factor Greater than 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition.LED light fitting 1 x 4' - 20/22 WEach740.0740.06.0FalseNoneNoneFalseNoneFalse4440.00
3927740151465None13, Item No.13.7.1Fixing all types and all capacities of fluorescent /false ceiling / spot light / CFL / LED fittings indoor on the wall/ ceiling / rafters / girders using 23/0.0076" twin twisted PVC insulated wires, required Nos of round blocks and clA.On wall/ ceiling / Rafter / GirdersEach119.0119.04.0FalseNoneNoneFalseNoneFalse476.00
3927741151465NoneItem No.5.7.3Supplying & fixing of porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers etc., complete. 63 AmpsEach372.0372.04.0FalseNoneNoneFalseNoneFalse1488.00
3927742151465NoneItem No.5.17.4Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898.6 - 32 Amps DPEach1103.01103.04.0FalseNoneNoneFalseNoneFalse4412.00
3927743151465NoneItem No.5.18.10Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure.16 Way SP & NEach2650.02650.04.0FalseNoneNoneFalseNoneFalse10600.00
3927744151465NoneItem No.5.20.1Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker ELMCB 240/450V up to 300mA sensitivity on existing wood/panel board.16-25 Amps 2 PoleEach2536.02536.03.0FalseNoneNoneFalseNoneFalse7608.00
3927745151465NoneItem No.5.42.2Fabricating supplying and mounting MS box made out 16 SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size ClA with necessary cable entry pipe with gland and box should be finished with 7 tanks treatment with powder coated paint and finally finished with approved colour etc., complete. 16 SWG Box 50 cm X 60 cm X 30 cmSq CM0.380.386000.0FalseNoneNoneFalseNoneFalse2280.00
3927746151465NoneItem No.11.11.4Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI Greater than 70 percentage. efficacy Greater than 80 lumen per W, life Greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF Greater than 0.95, power loss should less than 5 percentage of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20 percentage, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.9W, 6500KEach160.0160.04.0FalseNoneNoneFalseNoneFalse640.00
3927747151465NoneItem No.11.11.5Supplying & fixing of retrofit type - LED bulb ...... W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI Greater than 70 percentage. efficacy Greater than 80 lumen per W, life Greater than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF Greater than 0.95, power loss should lesser than 5 percentage of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20 percentage, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.12W, 6500KEach237.0237.02.0FalseNoneNoneFalseNoneFalse474.00
3927748151465NoneItem No 5.44.1Supply and Installation / Fixing / Provision of Outdoor type Thermoplastic Modular Panel enclosure with transparentPolycarbonate Lid, shock proof, IP65 (Weather Proof), rust proof, dust proof, water proof, corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cut-out with suitable transparent hinged flap opening for operating MCB along with complete tamper proof SEALING facility. 300 mm x 300 mm x 214 mm mm Out door Thermoplastic Modular PanelEach4054.04054.02.0FalseNoneNoneFalseNoneFalse8108.00
3927749151465NoneItem No. 7.1.2GEYSERS, HEATERS & SOLAR WATER HEATERS 7.1 Supplying.....litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside and anticorrosive paint outside and 20 SWG M.S. sheet metal outer cover filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting.15 LEach7560.07560.02.0FalseNoneNoneFalseNoneFalse15120.00
3927750151465NoneItem No. 32.041.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 16 Sqmm, 2 Core, (9 GI Strips - 4 x 0.8 mm)Km114683.0114683.00.04FalseNoneNoneFalseNoneFalse4587.320
3927751151465NoneItem No. 54.01Grounding Material Pipe Grounding GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 KgNo770.0770.01.0FalseNoneNoneFalseNoneFalse770.00
3927752151465NoneItem No. 54.02Grounding Material Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg eachNo660.0660.01.0FalseNoneNoneFalseNoneFalse660.00
3927753151465NoneItem No. 54.03Grounding Material Good Quality Salt for grounding purposes packed in 50 Kg gunny bagBag303.0303.01.0FalseNoneNoneFalseNoneFalse303.00
3927754151465NoneItem No. 56.05LT Single Phase 5-30 Amps, DLMS Complaint Static Energy Meter, 1.0 Accuracy Class (Used for LT-2, LT-3 & LT-5 Installations)No934.0934.01.0FalseNoneNoneFalseNoneFalse934.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17255219330000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17255219330000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17255219330000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17255219330000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17255219330000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17255309610000NoneNoneELIGIBILITYBlacklisted agencies/contractors are not eligible to participate in the tender.None
17255309860000NoneNoneELIGIBILITYThe work done certifcate attached should be issued by an ofcer not below the rank of Executive Engineer.None
17255310010000NoneNoneELIGIBILITYConditional LOC (Line of credit)/ Bankers certifcate shall not be accepted and the tender bid shall be rejected.None
17255310140000NoneNoneELIGIBILITYTurnover certifcate from CA with valid UDIN No. to be furnished along with necessary documents.None
17255310240000NoneNoneELIGIBILITYGST shall be paid to the tendered amount separately.None
17255310420001NoneNoneELIGIBILITYFinancial turnover of previous years shall be given a weightage of 10% per year to bring them to the price level of the 2024-25None
17255310660000NoneNoneELIGIBILITYTenderers are required to read the Bid Documents carefully before submission of their bid.None
17258710520000NoneNoneELIGIBILITYAll conditions as per bid document attached.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneTenderer in his name should have in the last five years i.e., 2019-20 to 2023-2 4satisfactory completed, at least one similar Building work of value not less than Rs. 39.10 Lakhs as prime contractor.Past ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneEach tenderer in its name should have in the last five years i.e., 2019-20 to 2023-24 Executed in any one year (for a continuous period of 12 months) the following minimum quantities of work 1. Earthwork excavation/Embankment-176.00 Cum 2.PCC/RCC/DLC/PQC-126.00Cum 3.Reinforcement Steel-11.00Tonns 4.All types of masonry-173.00cumPast ExperienceNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneBid capacity (AXNX2.5-B)Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- BID Capacity
NoneNoneNoneNoneCompany registration certifcateCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Registration Certifcate issued by the ofcer not below the rank of Chief Engineer or Equivalent
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs.23.46 Lakhs (estimated cash fow for 3 months of peak construction period (Unconditional Credit lines/ letters of credit/ certifcates from banks for meeting the fundCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneEach tenderer in its name should have in the last fve years i.e., 2019-20 to 2023-24nAchieved in at least two fnancial years a minimum annual fnancial turnover of Rs. 78.19 LakhsFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
List of existing commitments and ongoing worksTrueTechnical Bid
Work Done CertifcateTrueTechnical Bid
Line of credit certifcate/bankers certifcateTrueTechnical Bid
tenderWorkLocationList
tenderSubEstimateNamedistrictNametaluqNameloksabhaContNameassemblyContNamelocationDescriptionlatitudeDegreeslatitudeMinuteslatitudeSecondslongitudeDegreeslongitudeMinuteslongitudeSeconds
BuildingsShivamoggaTirthahalliShimogaTIRTHAHALLIThirthahalliNoneNoneNoneNoneNoneNone
BuildingsShivamoggaTirthahalliShimogaTIRTHAHALLIThirthahalliNoneNoneNoneNoneNoneNone
BuildingsShivamoggaTirthahalliShimogaTIRTHAHALLIThirthahalliNoneNoneNoneNoneNoneNone
tenderAddress
createdTs1725872437000
version0
createdDateNone
modifiedDateNone
blockNumberDistrict commisioner offce, Savalanga road DC office Shivamogga.
streetNone
cityShivamogga
stateKarnataka
pin577201
tenderRecallDTONone