createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1725860965038
version2
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyRESERVED
invitingStrategyTextReserved
taxTypeINCLUSIVE_TAX
tenderFee500.00
emd5000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose24-09-2024 17:30:00
tenderQueryClose23-09-2024 17:30:00
technicalBidOpen26-09-2024 11:30:00
publishedDate09-09-2024 14:37:00
publishedByPostCMC_MCOM_CMJ
publishedByUserKPE12757 - RAMADAS S V
bidValidityPeriod90
noOfCalls1
preBidMeetingDateNone
preBidMeetingYnFalse
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonManjunath
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedNone
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumberNone
mobileNumber9448872062
tenderSupplierListNone
tenderSchedule
createdTs1725860965067
version4
createdDateNone
modifiedDateNone
tenderNumberDMA/2024-25/OW/WORK_INDENT29250
titleConstruction of Toilet And Supplying of Electrification in PKS Vishranthi Gruha at Chamarajanagara CMC. (Reserved for ST)
descriptionConstruction of Toilet And Supplying of Electrification in PKS Vishranthi Gruha at Chamarajanagara CMC. (Reserved for ST)
categoryWORKS
categoryTextWorks
ecv395780.80
deptNameDirectorate of Municipal Administration
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnTrue
location2456
locationNameDMA City Municipal Council Chamarajanagara
provisionalAmount400000.0
groupOverheadTotal60373.34
fileNumberDMA/2024-25/Vishranthigruha
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17258609650000NoneNoneOther WorksConstruction of Toilet And Supplying of Electrification in PKS Vishranthi Gruha at Chamarajanagara CMC.335407.46
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3941461152493None1.6.1Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required to complete the work.In all kinds of soils. Depth upto 1.50m.(Common SR 2023-24 Page No- 06, Item No-1.6.1)(Common SR 2023-24 Page No- 06, Item No-1.6.1)Cum498.52498.5260.7FalseNoneNoneFalseNoneFalse30260.1640
3941462152493None1.10Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications. (PWD Vol-1 SR 2023-24, Item no. 1.10, Page No.7)Cum164.8164.859.4FalseNoneNoneFalseNoneFalse9789.120
3941463152493None3.1Removal of Unserviceable Soil with Disposal up to a suitable distance as directed by the Engineer in charge of work. (PWD SR Vol 3, 2023-24, Item no. 3.1, Page No.17)Cum87.5587.551.3FalseNoneNoneFalseNoneFalse113.8150
3941464152493None2.1.2Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates.(PWD SR Vol-01, 2023-24, Item no. 2.1.2, Page No.15)Cum5833.925833.921.52FalseNoneNoneFalseNoneFalse8867.55840
3941465152493None5.4Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand) (PWD SR Vol-02, 2023-24, Item no.5.4, Page No.9)Cum6580.676580.671.15FalseNoneNoneFalseNoneFalse7567.77050
3941466152493None2.5.2Providing and laying in position Cement Concrete for all Super structures of building, Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (PWD SR, Vol.1, 2023-24, Item no. 2.5.2, Page No.16)Cum7048.297048.290.88FalseNoneNoneFalseNoneFalse6202.49520
3941467152493None6.7Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:4 (1 cement : 4 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (PWD Vol-02 SR 2023-24, Item no. 6.7, Page No.13)Cum8457.338457.333.78FalseNoneNoneFalseNoneFalse31968.70740
3941468152493None2.11ASupplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. Buildings (PWD Vol-1 SR 2023-24, Item No. 2.11a, Page No. 18)MT92140.7192140.710.088FalseNoneNoneFalseNoneFalse8108.382480
3941469152493None8.4.1Providing 12 mm cement plaster finished with a floating coat of neat cement of mix :1:3 (1 cement: 3 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR Vol-02, 2023-24, Item no. 8.4.1, Page No.41)Sqm332.69332.6936.05FalseNoneNoneFalseNoneFalse11993.47450
3941470152493None9.11Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. (PWD SR Vol-02, 2023-24, Item no. 9.11, Page No.60)Sqm915.67915.6717.12FalseNoneNoneFalseNoneFalse15676.27040
3941471152493None12.53Providing & fixing 30mm thick factory made rigid foam Panelled Door Shutters made from M.S. tube of 19 gauge thickness, size 19x19mm for stiles and 15x15mm for top & bottom rails, covered with heat moulded PVC C channel of 5mm thick sheet & 30 x 50mm wide to form stiles & 5mm thick & 75mm wide PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick 20mm wide PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet fitted in the M.S. Frame, Sealed to the stiles & rails with 5x30mm PVC sheet beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer-in-charge fixed to frames with 3 nos of 75 mm Aluminium hinges. (PWD SR Vol-02, 2023-24, Item no. 12.53, Page No.104)Sqm1635.641635.643.15FalseNoneNoneFalseNoneFalse5152.2660
3941472152493None8.21Providing White washing with lime to give an even shade :New work (three coats) with lime of approved quality, including cost of materials, labour complete as per specifications and as per directions of Engineer-in- charge. (PWD SR Vol-02, 2023-24, Item no. 8.21, Page No.44)Sqm26.7826.7836.05FalseNoneNoneFalseNoneFalse965.4190
3941473152493None8.33.1Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life) (PWD SR Vol-02, 2023-24, Item no. 8.33.1, Page No.46)Sqm162.74162.7436.05FalseNoneNoneFalseNoneFalse5866.7770
3941474152493None7.38Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 m or as desired by Engineer in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.(PWD SR Vol-02, 2023-24, Item no.7.38, Page No.26)Sqm585.04585.0412.16FalseNoneNoneFalseNoneFalse7114.08640
3941475152493None1.1Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 g/m2 as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete.Ridges plain (500 - 600mmSqm464.53464.532.0FalseNoneNoneFalseNoneFalse929.060
3941476152493None1.1Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot restsEach4373.384373.382.0FalseNoneNoneFalseNoneFalse8746.760
3941477152493None14.7AProviding and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap. (PWD SR Vol-02, 2023-24, Item no. 14.7A, Page No.133)Each4244.634244.632.0FalseNoneNoneFalseNoneFalse8489.260
3941478152493None10.1.2Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testingand commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 32mm dia., 10 kg/sqcm & class 5. (PWD SR Vol-05, 2023-24, Item no. 10.1.2, Page No.113)m69.0169.0170.0FalseNoneNoneFalseNoneFalse4830.70
3941479152493None13.32.3Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.25 mm nominal dia pipes(Common SR-2023-24, Vol-02, Page no-122, I.No-13.32.3)m491.31491.3120.0FalseNoneNoneFalseNoneFalse9826.20
3941480152493None10.1.2Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testingand commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for:PVC pipes 110mm dia., 10 kg/sqcm & class 5. (PWD SR Vol-05, 2023-24, Item no. 10.1.2, Page No.113)m423.33423.3370.0FalseNoneNoneFalseNoneFalse29633.10
3941481152493None16.9Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame.(PWD SR Vol-05, 2023-24, Item no.16.9, Page No.191)Each5617.625617.622.0FalseNoneNoneFalseNoneFalse11235.240
3941482152493None10.8.2Supply and delivery at site special moulded variety PVC couplers as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark and with its latest amendments.32mm dia PVC couplers, (PWD SR Vol-05, 2023-24, ltem no. 10.8.2, Page No.116)Each16.4816.4810.0FalseNoneNoneFalseNoneFalse164.80
3941483152493None10.9.2Supply and delivery at site special moulded variety PVC elbows as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.32 mm dia PVC Elbows. (PWD SR Vol-05, 2023-24, ltem no.10.9.2, Page No.117)Each21.6321.6310.0FalseNoneNoneFalseNoneFalse216.30
3941484152493None10.11.2Supply and delivery at site special moulded variety PVC bend as per IS 7834/ 1987 and fabricated as per IG124/ 1984 with ISI mark with its latest amendments.32 mm dia PVC BEND. (PWD SR Vol-05, 2023-24, ltem no.10.11.2, Page No.118)Each37.0837.084.0FalseNoneNoneFalseNoneFalse148.320
3941485152493None13.4.2Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :32 mm nominal bore. (PWD SR Vol-02, 2023-24, ltem no.13.4.2, Page No.117)No615.94615.942.0FalseNoneNoneFalseNoneFalse1231.880
3941486152493None13.3.2Providing and fixing brass stop cock of approved quality : 20 mm nominal bore. (PWD SR Vol-02, 2023-24, ltem no.13.3.2, Page No.117)No314.15314.156.0FalseNoneNoneFalseNoneFalse1884.90
3941487152493None14.32.4Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. (PWD SR Vol-02, 2023-24, ltem no.14.32.4, Page No.136)No1256.61256.62.0FalseNoneNoneFalseNoneFalse2513.20
3941488152493None14.22AProviding and fixing CP Brass 32mm size Bottle Trap of approved quality & make and as per the direction of Engineer-in-charge. (PWD SR Vol-02, 2023-24, ltem no.14.22A, Page No.135)No834.3834.36.0FalseNoneNoneFalseNoneFalse5005.80
3941489152493None1.2.2Supplying heavy gauge PVC conduit pipe . mm dia.mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary, 25 mm dia 2 mm thick (PWD Electrical CSR 2023-24, IN-1.2.2, PN-2),No80.3480.3450.0FalseNoneNoneFalseNoneFalse4017.00
3941490152493None2.2.1Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR 2021-22, Short point upto 3m from tapping point to out let via switch box. (PWD Electrical CSR 2021-2022, IN-2.2.1, PN-5), Short point upto 3m from tapping point to out let via switch boxNo277.07277.0710.0FalseNoneNoneFalseNoneFalse2770.70
3941491152493None2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR 2021-22, Short point upto 3m from tapping point to out let via switch box. (PWD Electrical CSR 2023-24, IN-2.2.2, PN-5), Medium point above 3m upto 6m from tapping point to out let via switch box.No390.37390.3710.0FalseNoneNoneFalseNoneFalse3903.70
3941492152493None2.2.2Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. PWD Electrical SR 2021-22, Short point upto 3m from tapping point to out let via switch box. (PWD Electrical CSR 2023-24, IN-2.2.2, PN-5), Long point above 6m upto 10m from tapping point to out let via switch boxNo571.65571.6510.0FalseNoneNoneFalseNoneFalse5716.50
3941493152493None2.3.2Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 confirming to latest amendments.PWD Electrical CSR 2023-24, IN-2.3.2, PN-5), 1.5 mm2No26.7826.7850.0FalseNoneNoneFalseNoneFalse1339.00
3941494152493None2.3.3Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 confirming to latest amendments.PWD Electrical CSR 2023-24, IN-2.3.3, PN-5), 2.5 mm2No43.2643.2650.0FalseNoneNoneFalseNoneFalse2163.00
3941495152493None6.3.3Supplyingand fixing of modular switch & connected accessoriesonexisting modular switch plate as per IS 3854 and IS 1293. (PWD Electrical CSR 2023-24, IN-6.3.3, PN-9), 6A Three Way socket.No176.13176.134.0FalseNoneNoneFalseNoneFalse704.520
3941496152493None2.3.4Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS- 694 confirming to latest amendments. (PWD Electrical CSR 2023-24, IN-2.3.4, PN-5), 4 mm2No64.8964.8910.0FalseNoneNoneFalseNoneFalse648.90
3941497152493None3.1.2Supplying 6A flush type socket and 6 A flush type SP switch either surface/flush mounting in existing gang box or in 4mm thick plastic sheet and fixing over a flush mounted wooden box and wiring using necessary capacity wires as required as per IS 1293 and IS 3654, (PWD Electrical CSR 2023-24, IN-3.1.2, PN-8), 6A 3/5 WayNo151.41151.414.0FalseNoneNoneFalseNoneFalse605.640
3941498152493None3.4.3Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall, (PWD Electrical CSR 2023-24, IN-3.4.3, PN-8), 6 WayNo182.31182.314.0FalseNoneNoneFalseNoneFalse729.240
3941499152493None6.5.2Supplying wall mounting fan suitable to operate at single- phase 230v AC. supply.400 mm Sweep (PWD Ele SR 2-23-24 page no-30 item no-6.5.2)No3308.363308.364.0FalseNoneNoneFalseNoneFalse13233.440
3941500152493None3.5.3Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box, (PWD Electrical CSR 2023-24, IN-3.5.3, PN-8), 6 ModuleNo180.25180.2510.0FalseNoneNoneFalseNoneFalse1802.50
3941501152493None13.2.1Supplying and Fixing.mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/ tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires.(PWD Electrical CSR 2023-24, IN-13.2.1, PN-56), Using 25mm dia G.I.PipeNo1239.091239.091.0FalseNoneNoneFalseNoneFalse1239.090
3941502152493None11.3.1Supplying of .feet -PVC Batten with integrated LED tube .W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V@ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical conditionNo567.53567.534.0FalseNoneNoneFalseNoneFalse2270.120
3941503152493None11.11.5Supplying & fixing of retrofit type - LED bulb . W with OPAL acrylic diffuser comprising of LED source with CCT 6500 degree K, CRI 70%. efficacy 80 lumen per W, life25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition., (PWD Electrical CSR 2023-24, IN-11.11.5, PN-38(Part-1)), 12W, 6500KNo277.07277.076.0FalseNoneNoneFalseNoneFalse1662.420
3941504152493None3.14.6Supplying And fixing/replacing of 6/16/32A electrical accessories on existing switch board. (PWD Electrical CSR 2023-24, IN-3.14.6, PN-10), 6A Lamp HolderNo73.1373.136.0FalseNoneNoneFalseNoneFalse438.780
3941505152493None6.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. (PWD Electrical CSR 2023-24, IN-6.1, PN-30).No1492.01492.04.0FalseNoneNoneFalseNoneFalse5968.00
3941506152493None1.1Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. (PWD Electrical CSR 2023-24, IN-6.1, PN-30).No834.3834.34.0FalseNoneNoneFalseNoneFalse3337.20
3941507152493None5.18.4Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. (PWD Electrical CSR 2023-24, IN-5.18.4, PN-17).6-32 A DPNo761.17761.171.0FalseNoneNoneFalseNoneFalse761.170
3941508152493None5.42.2Fabricating supplying and mounting MS box made out .SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clA with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete. (PWD Electrical CSR 2023-24, IN-5.42.2, PN-20).16SWG.No0.440.448000.0FalseNoneNoneFalseNoneFalse3520.00
3941509152493None5.40Supplying . A rated 3phase with neutral bus bar using required capacity electrolytic aluminium strips covered with heat shrinkable coloured PVC sleeve, mounted on phenolic/FRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. (PWD Electrical CSR 2023-24, IN-5.40.1, PN-20).100 A 4 x 30 x 6 mm Aluminium StripsNo2538.952538.951.0FalseNoneNoneFalseNoneFalse2538.950
3941510152493None5.30Supplying, fixing and wiring Electronic Trivector Meter (ETV) 5 to 20A single phase Class-1 Accuracy with Temper Proof Energy Meter (PWD Electrical CSR 2023-24, IN-5.30, PN-19)No1421.41421.41.0FalseNoneNoneFalseNoneFalse1421.40
3941511152493None1.6.2Digging of Pit for providing GI Pipe type Earthing, Hard Soil, (Bescom CSR 2023-24, IN-1.6.2, PN-43)Per Pit3079.73079.71.0FalseNoneNoneFalseNoneFalse3079.70
3941512152493None54.01GI Grounding pipe, B - Class, 42 mm dia, 2.5 Mtr long, 3.2 mm thick with bolt, nut, GI Strips and washer complete Minimum Weight of GI Pipe: 7.3 Kg, (Bescom CSR 2021-22, IN-54.01, PN-17(Part-III))No765.29765.291.0FalseNoneNoneFalseNoneFalse765.290
3941513152493None51.02Good Quality well burnt Charcoal for grounding purposes packed in non returnable gunny bag of 30 Kg each, (Bescom CSR 2023-24, IN-51.02, PN-22)No696.28696.281.0FalseNoneNoneFalseNoneFalse696.280
3941514152493None51.03Good Quality Salt for grounding purposes packed in 50 Kg gunny bag, (Bescom CSR 2023-24, IN-51.03, PN-22)No319.3319.31.0FalseNoneNoneFalseNoneFalse319.30
3941515152493None32.031.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975, (Bescom CSR 2023-24, IN-32.03, PN-13), 10 Sqmm, 4 Core, (10 GI Strips - 4 x 0.8 mm)Km121544.12121544.120.06FalseNoneNoneFalseNoneFalse7292.64720
3941516152493None21.05Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable, (Bescom CSR 2023-24, IN-21.05, PN-52), 2.5 to 25 SqmmKm21512.5821512.580.08FalseNoneNoneFalseNoneFalse1721.00640
3941517152493None60.03Aluminium End Terminal (Lug), 25 Sqmm (Bescom CSR 2023-24, IN-60.03, PN-27)Each3.093.098.0FalseNoneNoneFalseNoneFalse24.720
3941518152493None47.04GI Pipe B - Class as per IS-1239, (Bescom CSR 2023-24, IN-49.04, PN-16(Part-III)), GI Pipe - 40 mm DiaMtr303.85303.854.0FalseNoneNoneFalseNoneFalse1215.40
3941519152493None1.1KEB Connections chargesLS25000.025000.01.0FalseNoneNoneFalseNoneFalse25000.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17258609660000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17258609660000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17258609660000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17258609660000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17258609660000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneGST registrationOthersGST registration
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneContractor Licenced certificateOthersContractor Licenced certificate
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNonePWD Registration Certificate (Class I/II/III/IV)
NoneNoneNoneNoneCaste & Domocial certificate (ST)OthersCaste & Domocial certificate (ST)
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Caste & Domocial certificate (ST)
NoneNoneNoneNoneScanned Copy of FD in Favour of Muncipal Commissioner, CMC, Chamarajanagara for Negitive Premium Amount (Difference Amount)OthersScanned Copy of FD
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned Copy of FD in Favour of Muncipal Commissioner, CMC, Chamarajanagara for Negitive Premium Amount (Difference Amount)
NoneNoneNoneNoneAchieved in at least two financial years a minimum financial turnoverOthersturnover
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateFalseTechnical Bid
Company Registration CertificateFalseTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
tenderWorkLocationList
tenderAddressNone
tenderRecallDTONone