1725361908000 | 1 | None | None | Buildings | Proposed construction of compound wall to SWM vehicle shed and other development works in Ullal CMC limit | 2099880.69 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3907950 | 150721 | None | PWDSR01 | Demolishing R.C.C. work manually/ by mechanical means including
stacking of steel bars and disposal of unserviceable material to the
appropriate disposal area as per direction of Engineer-in-charge | Cum | 2080.96 | 2080.96 | 22.2 | False | None | None | False | None | False | 46197.312 | 0 | 3907951 | 150721 | None | PWDSR01 | Earth work excavation by manual means for drains,canals, waste weir, draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work | Cum | 271.04 | 271.04 | 27.0 | False | None | None | False | None | False | 7318.08 | 0 | 3907952 | 150721 | None | PWDSR01 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to coplete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6442.24 | 6442.24 | 4.95 | False | None | None | False | None | False | 31889.088 | 0 | 3907953 | 150721 | None | PWDSR01 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification. I.S. 3620/1979 having compressive strength not less then 3.5 N/mm2 for saturated dry samples. For super structure in CM 1:6 (Cement 45kgs/M3) | Cum | 4939.2 | 4939.2 | 27.05 | False | None | None | False | None | False | 133605.36 | 0 | 3907954 | 150721 | None | PWDSR01 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant ISCodes machine mixed with super plasticisers, laidin layers, well compacted using needle vibrators, providing weep holes wherever necesary, includingall lead & lifts, cost of all materials of quality,confirming to the requirements of relevant IS codes,labour, Usage charges of machinery, curing and allother ppurtenances required to complete the workas per echnical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal sizegraded crushed coarse aggregates | Cum | 7018.37 | 7018.37 | 1.52 | False | None | None | False | None | False | 10667.9224 | 0 | 3907955 | 150721 | None | VOLUM2 | Providing and fixing Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Kg | 126.56 | 126.56 | 831.6 | False | None | None | False | None | False | 105247.296 | 0 | 3907956 | 150721 | None | VOLUM2 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (Out side) | Sqm | 350.56 | 350.56 | 160.8 | False | None | None | False | None | False | 56370.048 | 0 | 3907957 | 150721 | None | VOLUM2 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paer smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 152.32 | 152.32 | 138.54 | False | None | None | False | None | False | 21102.4128 | 0 | 3907958 | 150721 | None | VOLUM2 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In all kinds of soils Depth upto 3 m | Cum | 81.76 | 81.76 | 31.28 | False | None | None | False | None | False | 2557.4528 | 0 | 3907959 | 150721 | None | VOLUM2 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to coplete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6442.24 | 6442.24 | 13.19 | False | None | None | False | None | False | 84973.1456 | 0 | 3907960 | 150721 | None | VOULM1 | Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand | Cum | 6072.64 | 6072.64 | 9.52 | False | None | None | False | None | False | 57811.5328 | 0 | 3907961 | 150721 | None | VOLUM1 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification. I.S. 3620/1979 having compressive strength not less then 3.5 N/mm2 for saturated dry samples. For super structure in CM 1:6 (Cement 45kgs/M3 | Cum | 4939.2 | 4939.2 | 23.29 | False | None | None | False | None | False | 115033.968 | 0 | 3907962 | 150721 | None | PWDSR01 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer including cost of materials ,labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge | Cum | 9269.12 | 9269.12 | 36.0 | False | None | None | False | None | False | 333688.32 | 0 | 3907963 | 150721 | None | VOLUM1 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant ISCodes machine mixed with super plasticisers, laidin layers, well compacted using needle vibrators, providing weep holes wherever necesary, includingall lead & lifts, cost of all materials of quality,confirming to the requirements of relevant IS codes,labour, Usage charges of machinery, curing and allother ppurtenances required to complete the workas per echnical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal sizegraded crushed coarse aggregates | Cum | 7218.89 | 7218.89 | 9.75 | False | None | None | False | None | False | 70384.1775 | 0 | 3907964 | 150721 | None | PWDSR01 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant ISCodes machine mixed with super plasticisers, laidin layers, well compacted using needle vibrators, providing weep holes wherever necesary, includingall lead & lifts, cost of all materials of quality,confirming to the requirements of relevant IS codes,labour, Usage charges of machinery, curing and allother ppurtenances required to complete the workas per echnical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal sizegraded crushed coarse aggregates | Cum | 10026.24 | 10026.24 | 23.81 | False | None | None | False | None | False | 238724.7744 | 0 | 3907965 | 150721 | None | PWDSR01 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant ISCodes machine mixed with super plasticisers, laidin layers, well compacted using needle vibrators, providing weep holes wherever necesary, includingall lead & lifts, cost of all materials of quality,confirming to the requirements of relevant IS codes,labour, Usage charges of machinery, curing and allother ppurtenances required to complete the workas per echnical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal sizegraded crushed coarse aggregates | Cum | 11363.07 | 11363.07 | 2.48 | False | None | None | False | None | False | 28180.4136 | 0 | 3907966 | 150721 | None | PWDSR01 | Providing and laying in position Reinforced cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant ISCodes machine mixed with super plasticisers, laidin layers, well compacted using needle vibrators, providing weep holes wherever necesary, includingall lead & lifts, cost of all materials of quality,confirming to the requirements of relevant IS codes,labour, Usage charges of machinery, curing and allother ppurtenances required to complete the workas per echnical specifications. (The cost of steel reinforcement & formwork to be paid separately) M20 Design Mix Using 20 mm nominal sizegraded crushed coarse aggregates | Cum | 10694.66 | 10694.66 | 4.23 | False | None | None | False | None | False | 45238.4118 | 0 | 3907967 | 150721 | None | PWDSR01 | Providing Thermo-Mechanically Treated bars of grade Fe-550 Steel reinforcement for R.C.C. work including straightening, cut ting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately | Kg | 94153.92 | 94153.92 | 4.104 | False | None | None | False | None | False | 386407.68768 | 0 | 3907968 | 150721 | None | PWDSR01 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materi als, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Cum | 226.24 | 226.24 | 440.1 | False | None | None | False | None | False | 99568.224 | 0 | 3907969 | 150721 | None | PWDSR01 | Finishing with Deluxe Multi surface paint system for interiors and exte riors using Primer as per manufacturers specifications: Two coats ap plied on walls @ 1.25 ltr/10 m² over and including one coat of Special primer applied @ 0.75 ltr /10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge | Sqm | 132.2 | 132.2 | 440.1 | False | None | None | False | None | False | 58181.22 | 0 | 3907970 | 150721 | None | PWDSR01 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joint with white cement & matching pigments etc. complete | Sqm | 1244.32 | 1244.32 | 112.5 | False | None | None | False | None | False | 139986.0 | 0 | 3907971 | 150721 | None | PWDSR01 | Concealed Conduit System: Supplying 19/20 mm dia 2mm thick heavy gauge PVC conduit pipe with suitable size bends, metal / PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary etc., including cost and conveyance of all materials, labour, HOM of equipments, all lead and lift and all other incidental charges etc., complete as per standard technical specifications and as directed by the Engineer-in-charge of the work | m | 44.8 | 44.8 | 30.0 | False | None | None | False | None | False | 1344.0 | 0 | 3907972 | 150721 | None | PWDSR01 | Groove cutting in the wall supplying 19/20mm dia 2mm thick heavy gauge PVC Conduit Pipe with bends, metal junction boxes adhesive paste etc.,and bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary etc., including cost and conveyance of all materials, labour, HOM of equipments, all lead and lift and all other incidental charges etc., complete as per standard technical specifications and as directed by the Engineer-in-charge of the work. | m | 57.12 | 57.12 | 90.0 | False | None | None | False | None | False | 5140.8 | 0 | 3907973 | 150721 | None | PWDSR01 | Supplying and fixing PVC/metal conduit accessories: 19/20mm Special type junction box including cost and conveyance of all materials, labour, HOM of equipments, all lead and lift and all other incidental charges etc., complete as per standard technical specifications and as directed by the Engineer-in-charge of the work | Each | 48.16 | 48.16 | 60.0 | False | None | None | False | None | False | 2889.6 | 0 | 3907974 | 150721 | None | PWDSR01 | Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely | Each | 24.64 | 24.64 | 1.0 | False | None | None | False | None | False | 24.64 | 0 | 3907975 | 150721 | None | PWDSR01 | Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely | Each | 106.4 | 106.4 | 20.0 | False | None | None | False | None | False | 2128.0 | 0 | 3907976 | 150721 | None | PWDSR01 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box - II. Group-B a) 1 to 3 Module including cost and conveyance of all materials, labour, HOM of equipments, all lead and lift and all other incidental charges etc., complete as per standard technical specifications and as directed by the Engineer-in-charge of the work | Each | 123.2 | 123.2 | 16.0 | False | None | None | False | None | False | 1971.2 | 0 | 3907977 | 150721 | None | PWDSR01 | Supplying and fixing of modular switch/ Socket/stepped electronic fan regulator/ dimmer/telephone socket etc on existing modular switch plate - II. Using Group "A" materials a) 6Amps one way including cost and conveyance of all materials, labour, HOM of equipments, all lead and lift and all other incidental charges etc., complete as per standard technical specifications and as directed by the Engineer-in-charge of the work | Each | 78.4 | 78.4 | 20.0 | False | None | None | False | None | False | 1568.0 | 0 | 3907978 | 150721 | None | PWDSR01 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box - II. Group-B a) 1 to 3 Module including cost and conveyance of all materials, labour, HOM of equipments, all lead and lift and all other incidental charges etc., complete as per standard technical specifications and as directed by the Engineer-in-charge of the work | Each | 123.2 | 123.2 | 20.0 | False | None | None | False | None | False | 2464.0 | 0 | 3907979 | 150721 | None | PWDSR01 | Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping using copper PVC insulated multi strand 2x1.5Sqmm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet - I. Point wiring using class A Materials a) Short point up to 3Mtr from tapping point to out let via switch box including cost and conveyance of all materials, labour, HOM of equipments, all lead and lift and all other incidental charges etc., complete as per standard technical specifications and as directed by the Engineer-in-charge of the work | Each | 179.2 | 179.2 | 8.0 | False | None | None | False | None | False | 1433.6 | 0 | 3907980 | 150721 | None | PWDSR01 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc using 40mm dia 2.9mm thick 2.5 mtr long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode. The funnel should be enclosed in a CC chamber of 400x400x400mm with a cast iron cover. The earth electrode shall have staggered holes of 12mm dia and the electrode should be covered 150mm alround with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts including cost and conveyance of all materials, labour, HOM of equipments, all lead and lift and all other incidental charges etc., complete as per standard technical specifications and as directed by the Engineer-in-charge of the work | No | 4648.0 | 4648.0 | 1.0 | False | None | None | False | None | False | 4648.0 | 0 | 3907981 | 150721 | None | VOLUM1 | Supplying, fixing and wiring Earth Leakage Miniature Circuit Breaker [ELMCB] 240/450V up to 300mA sensitivity on existing wood/panel board - c) 32-40 Amps 4 pole including cost and conveyance of all materials, labour, HOM of equipments, all lead and lift and all other incidental charges etc., complete as per standard technical specifications and as directed by the Engineer-in-charge of the work | Each | 3136.0 | 3136.0 | 1.0 | False | None | None | False | None | False | 3136.0 | 0 |
|