3815734 | 144952 | None | code01 | Earth work excavation for Foundation by Mechanical means depth upto 1.50m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including cost of explosives, dressing of excavated surfaces, disposing off or levelling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, blasting materials, tools, usage of Machinery & all other appurtenaces required required to complete the work (PWD SR Vol-1 2023-24; P.No. 9; Serial NO. 1.16) | Cum | 581.7 | 581.7 | 14.58 | False | None | None | False | None | False | 8481.186 | 0 |
3815735 | 144952 | None | code02 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/ trap/ basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) 2.1.3 Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates (PWD SR Vol-1 2023-24; P.No. 15; Serial NO. 2.1.3) | Cum | 6288.45 | 6288.45 | 3.27 | False | None | None | False | None | False | 20563.2315 | 0 |
3815736 | 144952 | None | code03 | Providing and laying in position Cement Concrete for all Foundation works.
The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. (PWD SR Vol-1 2023-24; P.No. 15; Serial NO. 2.2.1) | Cum | 6601.35 | 6601.35 | 3.6495 | False | None | None | False | None | False | 24091.626825 | 0 |
3815737 | 144952 | None | code04 | Addendum I-Additionalities for formwork, Centering & Scaffolding " For Foundation upto Plinth (a) Isolated " at 8% | Cum | 528.1 | 528.1 | 3.6495 | False | None | None | False | None | False | 1927.30095 | 0 |
3815738 | 144952 | None | code05 | Providing and laying in Reinforced cement concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork to be paid separately) 2.3.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (PWD SR Vol-1 2023-24; P.No. 16; Serial NO. 2.3.1) | Cum | 6804.0 | 6804.0 | 0.31 | False | None | None | False | None | False | 2109.24 | 0 |
3815739 | 144952 | None | code06 | Appendix I-Additionalities for formwork, Centering & Scaffolding " For Columns " at 70% | Cum | 4762.79 | 4762.79 | 0.31 | False | None | None | False | None | False | 1476.4649 | 0 |
3815740 | 144952 | None | code07 | 2.5 Providing and laying in position Reinforced cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately) 2.5.2 M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. (PWD SR Vol-1 2023-24; P.No. 16; Serial NO. 2.5.2) | Cum | 7185.15 | 7185.15 | 6.89 | False | None | None | False | None | False | 49505.6835 | 0 |
3815741 | 144952 | None | code08 | Addendum I-Additionalities for formwork, Centering & Scaffolding " For Chejjas, Canopy & Other Architectural projections of monor sections " at 45% | Cum | 3233.31 | 3233.31 | 0.73 | False | None | None | False | None | False | 2360.3163 | 0 |
3815742 | 144952 | None | code09 | Addendum I-Additionalities for formwork, Centering & Scaffolding " For Roof slab of Buildings " at 50% | Cum | 3592.57 | 3592.57 | 4.5 | False | None | None | False | None | False | 16166.565 | 0 |
3815743 | 144952 | None | code10 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. (PWD SR Vol-2 2023-24; P.No. 14; Serial NO. 6.8) | Cum | 8367.45 | 8367.45 | 23.3547 | False | None | None | False | None | False | 195419.284515 | 0 |
3815744 | 144952 | None | code11 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification. (PWD SR Vol-1 2023-24; P.No. 18; Serial NO. 2.11 a) | MT | 93929.85 | 93929.85 | 1.08 | False | None | None | False | None | False | 101444.238 | 0 |
3815745 | 144952 | None | code12 | 12.13.1 Providing Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications. (PWD SR Vol-2 2023-24; P.No. 100; Serial NO. 12.13.1) | Cum | 103755.75 | 103755.75 | 0.066 | False | None | None | False | None | False | 6847.8795 | 0 |
3815746 | 144952 | None | code13 | 12.15 Providing and fixing in position fully panelled Honne wood shutters for doors with stiles and rails of 40mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. ( excluding cost of fixtures ) (PWD SR Vol-2 2023-24; P.No. 100; Serial NO. 12.15) | Sqm | 7241.85 | 7241.85 | 2.52 | False | None | None | False | None | False | 18249.462 | 0 |
3815747 | 144952 | None | code14 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. (PWD SR Vol-2 2023-24; P.No. 86; Serial NO. 11.36 B) | Sqm | 192.15 | 192.15 | 120.96 | False | None | None | False | None | False | 23242.464 | 0 |
3815748 | 144952 | None | code15 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) (PWD SR Vol-2 2023-24; P.No. 110; Serial NO. 12.90) | Sqm | 7070.7 | 7070.7 | 5.76 | False | None | None | False | None | False | 40727.232 | 0 |
3815749 | 144952 | None | code16 | Providing 12 mm cement plaster with cement mortar 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR Vol-2 2023-24; P.No. 41; Serial NO. 8.1.1) - Inside Plaster | Sqm | 267.75 | 267.75 | 192.82 | False | None | None | False | None | False | 51627.555 | 0 |
3815750 | 144952 | None | code17 | Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster with cement mortar 1:6 (1 cement : 6 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. (PWD SR Vol-2 2023-24; P.No. 42; Serial NO. 8.8) - Outside Plaster | Sqm | 389.55 | 389.55 | 117.3125 | False | None | None | False | None | False | 45699.084375 | 0 |
3815751 | 144952 | None | code18 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm. (PWD SR Vol-2 2023-24; P.No. 60; Serial NO. 9.12.2) | Sqm | 1202.25 | 1202.25 | 19.11 | False | None | None | False | None | False | 22974.9975 | 0 |
3815752 | 144952 | None | code19 | Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR Vol-2 2023-24; P.No. 46; Serial NO. 8.30) | Sqm | 182.7 | 182.7 | 117.3125 | False | None | None | False | None | False | 21432.99375 | 0 |
3815753 | 144952 | None | code20 | Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in- charge. (PWD SR Vol-2 2023-24; P.No. 104; Serial NO. 12.54) | Rmtr | 333.9 | 333.9 | 11.2 | False | None | None | False | None | False | 3739.68 | 0 |
3815754 | 144952 | None | code21 | Providing and fixing flush door shutter made out of solid core block board
type, well seasoned , chemicaly treated hard wood battens and internal
frame with minimum 45 mm wide wooden frame alround door shutters
covered with cross bonded wooden sheets (core veneer) hot pressed and
fastened on both sides of the door useing liquid phenol formaldehyde
resin as per IS specifications 2202 (part-I) 1991. from manufacturer
complete as per spcification. (PWD SR Vol-2 2023-24; P.No. 105; Serial NO. 12.57) | Sqm | 4245.15 | 4245.15 | 3.78 | False | None | None | False | None | False | 16046.667 | 0 |
3815755 | 144952 | None | code22 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 g/L and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 L/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 L/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (PWD SR Vol-2 2023-24; P.No. 46; Serial NO. 8.32) | Sqm | 163.8 | 163.8 | 192.82 | False | None | None | False | None | False | 31583.916 | 0 |
3815756 | 144952 | None | code23 | Supplying and fixing of PVC casing and capping on the wall or ceiling using necessary materials like bends, junction box, elbows, screws at an interval of 300 mm .... etc. as required.25mm | Mtr | 35.0 | 35.0 | 20.0 | False | None | None | False | None | False | 700.0 | 0 |
3815757 | 144952 | None | code24 | Supplying and flush mounting teak wooden box without front plank, made of not less than 12 mm thick wood, after due groove cutting, finishing with necessary cement plastering complete4"x4"x3" ( 101x101x76mm). | Each | 74.0 | 74.0 | 4.0 | False | None | None | False | None | False | 296.0 | 0 |
3815758 | 144952 | None | code25 | I. Point wiring using Copper wire with switchSupplying and wiring adopting loop system in existing PVC Conduit /casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) with a 6A flush type SP control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round
block. complete for each outlet.b) Medium point above 3Mtr up to 6Mtr from tapping point to out let via switch | Point | 394.0 | 394.0 | 1.0 | False | None | None | False | None | False | 394.0 | 0 |
3815759 | 144952 | None | code26 | c) Long point above 6Mtr up to 10Mtr from tapping point to out let via switch | Point | 570.0 | 570.0 | 1.0 | False | None | None | False | None | False | 570.0 | 0 |
3815760 | 144952 | None | code27 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS 694:confirming to latest amendments1.5 sqmm | Mtr | 26.0 | 26.0 | 60.0 | False | None | None | False | None | False | 1560.0 | 0 |
3815761 | 144952 | None | code28 | 2.5 sqmm | Mtr | 42.0 | 42.0 | 20.0 | False | None | None | False | None | False | 840.0 | 0 |
3815762 | 144952 | None | code29 | Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-3Way | Each | 138.0 | 138.0 | 1.0 | False | None | None | False | None | False | 138.0 | 0 |
3815763 | 144952 | None | code30 | 8Way | Each | 261.0 | 261.0 | 1.0 | False | None | None | False | None | False | 261.0 | 0 |
3815764 | 144952 | None | code31 | Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. | Each | 161.0 | 161.0 | 1.0 | False | None | None | False | None | False | 161.0 | 0 |
3815765 | 144952 | None | code32 | 8Moudule | Each | 284.0 | 284.0 | 1.0 | False | None | None | False | None | False | 284.0 | 0 |
3815766 | 144952 | None | code33 | Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way. | Each | 102.0 | 102.0 | 1.0 | False | None | None | False | None | False | 102.0 | 0 |
3815767 | 144952 | None | code34 | Stepped Fan Regulator. | Each | 357.0 | 357.0 | 1.0 | False | None | None | False | None | False | 357.0 | 0 |
3815768 | 144952 | None | code35 | 16Amps one way switch | Each | 180.0 | 180.0 | 1.0 | False | None | None | False | None | False | 180.0 | 0 |
3815769 | 144952 | None | code36 | 32Amps DP switch | Each | 326.0 | 326.0 | 1.0 | False | None | None | False | None | False | 326.0 | 0 |
3815770 | 144952 | None | code37 | 6/16Amps universal socket | Each | 236.0 | 236.0 | 1.0 | False | None | None | False | None | False | 236.0 | 0 |
3815771 | 144952 | None | code38 | 6Amps 3way socket. | Each | 171.0 | 171.0 | 3.0 | False | None | None | False | None | False | 513.0 | 0 |
3815772 | 144952 | None | code39 | Supplying of feet PVC Batten with integrated LED tube W with high quality diffuser with Life of 25000 burning hours 70 lumen maintenance with CRI 80 Power Input: 220 240V 50 60Hz Power factor 0.9 along with CE approved. years Warranty against any manufacturing defect working under standard electrical condition.12.3.2 LED light fitting 1 420 22 w Each LED light fitting 1 4 20 22 w Each | Each | 690.0 | 690.0 | 6.0 | False | None | None | False | None | False | 4140.0 | 0 |
3815773 | 144952 | None | code40 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. | Each | 241.0 | 241.0 | 1.0 | False | None | None | False | None | False | 241.0 | 0 |
3815774 | 144952 | None | code41 | Supplying and fixing regular MCB distribution boards on wall/ood board / flush mounting using required clA, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase/3 phase/single door with powder coated painting Made out of 14 SWG MS enclosure. | Each | 415.0 | 415.0 | 1.0 | False | None | None | False | None | False | 415.0 | 0 |
3815775 | 144952 | None | code42 | Group 'A' | Each | 739.0 | 739.0 | 1.0 | False | None | None | False | None | False | 739.0 | 0 |
3815776 | 144952 | None | code43 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure. | Each | 1524.0 | 1524.0 | 1.0 | False | None | None | False | None | False | 1524.0 | 0 |
3815777 | 144952 | None | code44 | Regular model | Each | 2984.0 | 2984.0 | 1.0 | False | None | None | False | None | False | 2984.0 | 0 |
3815778 | 144952 | None | code45 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. | Each | 87.0 | 87.0 | 1.0 | False | None | None | False | None | False | 87.0 | 0 |
3815779 | 144952 | None | code46 | Supply and fixing polished wood board made of not less than 15mm thick plank on both sides of not more than 2 pieces and fixing the same to the wall using tapered inverted wooden plugs screws. | Each | 162.0 | 162.0 | 1.0 | False | None | None | False | None | False | 162.0 | 0 |
3815780 | 144952 | None | code47 | Fixing a ceiling /wall mounting fan of all apacities and all types, with necessary clA and 'S' hook made out of 15mm dia MS rod, with 5 A. ceiling rose of approved quality with necessary length of 23/0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired. | Each | 315.0 | 315.0 | 1.0 | False | None | None | False | None | False | 315.0 | 0 |
3815781 | 144952 | None | code48 | Supplying PVC/GI flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of the pipe terminated completely | Mtr | 19.0 | 19.0 | 10.0 | False | None | None | False | None | False | 190.0 | 0 |