createdTsNone
versionNone
createdDateNone
modifiedDateNone
noticeInvitingTenderDTO
createdTs1726048535580
version4
createdDateNone
modifiedDateNone
tenderTypeRFQ
evaluationTypeTWO_COVER
evaluationTypeTextTwo Cover
invitingStrategyOPEN
invitingStrategyTextOpen
taxTypeINCLUSIVE_TAX
tenderFee5000.00
emd1025000.00
bidValueTypeITEM_WISE
bidValueTypeTextItem wise
tenderReceiptClose14-10-2024 16:00:00
tenderQueryClose25-09-2024 16:00:00
technicalBidOpen16-10-2024 16:00:00
publishedDate11-09-2024 19:45:32
publishedByPostKHB_EE_CO_BNG
publishedByUserKPE11677 - SHIVASHANKARAPPA K H
bidValidityPeriod180
noOfCalls1
preBidMeetingDate26-09-2024 11:00:00
preBidMeetingYnTrue
preQualificationBidOpenNone
denominationTypeRUPEES
denominationTypeTextRupees
retenderedYnNone
percentageRateTypeTextNone
contactPersonSHIVASHANKARAPPA K H
splitEmdRequiredYnFalse
emdBankGuaranteeNone
emdCashNone
bgValidityPeriodNone
hideWeightageNone
multipleCurrencySelectionAllowedYnFalse
isTechWeightageAllowedFalse
highestBidderSelectionFalse
isVariableEmdAllowedNone
qcbsTenderYnNone
itemwiseEmdRequiredYnNone
sampleSubmissionDateNone
officeNumber08022273511
mobileNumber8022273511
tenderSupplierListNone
tenderSchedule
createdTs1726048535601
version6
createdDateNone
modifiedDateNone
tenderNumberKHB/2024-25/BD/WORK_INDENT274
titleConstruction of Hostel Building (G Plus 4) at Minority Welfare Department-Morarji Desai Residential School at Anwar Village, Chincholi Taluk, Kalaburagi District
descriptionConstruction of Hostel Building (G Plus 4) at Minority Welfare Department-Morarji Desai Residential School at Anwar Village, Chincholi Taluk, Kalaburagi District
categoryWORKS
categoryTextWorks
ecv68148633.98
deptNameKarnataka Housing Board
statusPUBLISHED
statusTextPublished
remarksNone
csrValueNone
ecvtenderYnFalse
location5488
locationNameKHB Central Office Bengaluru
provisionalAmount68148634.0
groupOverheadTotalNone
fileNumberKHB/CE/AE-1/MWD/425/2024-25
tenderSubEstimateList
createdTsversioncreatedDatemodifiedDateworkCategoryNamesubEstimateNameestimateTotalitemList
17260485360000NoneNoneBuildingsConstruction of Hostel Building (G Plus 4) at Minority Welfare Department-Morarji Desai Residential School at Anwar Village, Chincholi Taluk, Kalaburagi District68148633.98
idtenderSubEstimateIdcategoryNameitemCodedescriptionuomNamebaseRatefinalRatequantitymodifyQuantityYnminQuantitymaxQuantitybuyBackYnbuyBackValuehideYnnetAmounttaxCount
3956753153364Nonecode01JUNGLE CLEARANCE Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, including removal and disposal of top organic soil not exceeding 150 mm in thickness.-By Mechanical Means using Dozer-In area of light jungle SR 2023-24 Page No. 9,Sl. No.2.5 A. VOL-3 ii a Rate per 100SqmSqm412.65412.658.4489FalseNoneNoneFalseNoneFalse3486.4385850
3956754153364Nonecode02Earth work in surface excavation for stripping, seating of bund, Road way, by manual means for lowering & leveling the ground for all works other than foundation & depth in all kinds of soil not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.Page No. 5,Sl. No.1.1 . VOL-1Sqm95.5595.55702.0FalseNoneNoneFalseNoneFalse67076.10
3956755153364Nonecode03EARTH WORK FOR BUILDING Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work- In all kinds of soils Depth upto 3 m SR 2023-24 Page No. 8,Sl. No.1.14.1 A. VOL-1Cum107.1107.11330.76FalseNoneNoneFalseNoneFalse142524.3960
3956756153364Nonecode04Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work- In ordinary/soft rock without blasting SR 2023-24 (P.No.8, Vol-1, SI.No.1.15.1 ) soft rock without blasting 20%Cum381.15381.15332.69FalseNoneNoneFalseNoneFalse126804.79350
3956757153364Nonecode05CC 1:3:6 For Bed ConcreteProviding and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 Using 40 mm nominal size graded crushed coarseaggregates SR 2023-24 Sl.No 2.1.3, Page No.15- VOL-1Cum6288.456288.4581.96FalseNoneNoneFalseNoneFalse515401.3620
3956758153364Nonecode06ANTI TERMITE TREATMENT Providing and injecting chemical emulsion for Preconstructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications Sl.No 4.1/ Page No. 5- VOL-2Sqm123.9123.9525.0FalseNoneNoneFalseNoneFalse65047.50
3956759153364Nonecode07RCC M25 FOR FOOTING & PEDESTAL Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications)- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 8% ON CONCRETE ITEM) SR -23-24 P-15 SI. No.2.2.3 VOL-1Cum7185.027185.02352.45FalseNoneNoneFalseNoneFalse2532360.2990
3956760153364Nonecode08RCC M25 FOR FOOTING & PEDESTAL Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications)- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 8% ON CONCRETE ITEM) SR -23-24 P-15 SI. No.2.2.3 VOL-1 PEDESTALCum7318.087318.0812.64FalseNoneNoneFalseNoneFalse92500.53120
3956761153364Nonecode09RCC COLUMN Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I upto plinthCum12214.7612214.7616.92FalseNoneNoneFalseNoneFalse206673.73920
3956762153364Nonecode10RCC COLUMN Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I GROUND FLOORCum12214.7612214.7625.92FalseNoneNoneFalseNoneFalse316606.57920
3956763153364Nonecode11RCC COLUMN Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FIRST FLOORCum12336.912336.925.92FalseNoneNoneFalseNoneFalse319772.4480
3956764153364Nonecode12RCC COLUMN Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I SECOND FLOORCum12460.2712460.2725.92FalseNoneNoneFalseNoneFalse322970.19840
3956765153364Nonecode13RCC COLUMN Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I THIRD FLOORCum12584.8712584.8725.92FalseNoneNoneFalseNoneFalse326199.83040
3956766153364Nonecode14RCC COLUMN Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FOURTH FLOORCum12710.7212710.7225.92FalseNoneNoneFalseNoneFalse329461.86240
3956767153364Nonecode15RCC COLUMN Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I HEAD ROOMCum12837.8312837.831.73FalseNoneNoneFalseNoneFalse22209.44590
3956768153364Nonecode16RCC COLUMN(DUMMY COLUMNS) Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 ) Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 70% ON CONCRETE ITEM) Page 15, Sl. No.2.1.4, Volume-ICum11097.3511097.355.83FalseNoneNoneFalseNoneFalse64697.55050
3956769153364Nonecode17PCC M15 FOR DPC Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates Page 15, Sl. No.2.1.4, Volume-ICum6527.856527.851.54FalseNoneNoneFalseNoneFalse10052.8890
3956770153364Nonecode18EARTH REFILLING Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. SL.No 1.9, Page No.7 Volume-ICum279.3279.31199.48FalseNoneNoneFalseNoneFalse335014.7640
3956771153364Nonecode19EARTH FILLING UPTO FLOORING PCC Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. SL.No 1.9, Page No.7 Volume-ICum279.3279.3463.96FalseNoneNoneFalseNoneFalse129584.0280
3956772153364Nonecode20Balance Soil have to brought from Outside Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work. SL.No 1.8, Page No.7 Volume-ICum497.7497.7399.59FalseNoneNoneFalseNoneFalse198875.9430
3956773153364Nonecode21Flooring Bed Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 Using 40 mm nominal size graded crushed coarse aggregates Sl.No 2.1.3, Page No.15- VOL-1Cum6288.456288.4543.51FalseNoneNoneFalseNoneFalse273610.45950
3956774153364Nonecode22RCC M25 FOR PLINTH BEAM Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.---- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.4.3 Page No.17 VOL-1Cum9979.29979.276.05FalseNoneNoneFalseNoneFalse758918.160
3956775153364Nonecode23CC BLOCKS 200mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.32, Page No.17, Volume-II GROUND FLOORSqm1375.51375.5292.77FalseNoneNoneFalseNoneFalse402705.1350
3956776153364Nonecode24CC BLOCKS 200mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.32, Page No.17, Volume-II FIRST FLOORSqm1389.261389.26264.95FalseNoneNoneFalseNoneFalse368084.4370
3956777153364Nonecode25CC BLOCKS 200mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.32, Page No.17, Volume-II SECOND FLOORSqm1403.151403.15264.95FalseNoneNoneFalseNoneFalse371764.59250
3956778153364Nonecode26CC BLOCKS 200mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.32, Page No.17, Volume-II THIRD FLOORSqm1417.181417.18264.95FalseNoneNoneFalseNoneFalse375481.8410
3956779153364Nonecode27CC BLOCKS 200mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x200x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.32, Page No.17, Volume-II FOURTH FLOORSqm1431.351431.35264.95FalseNoneNoneFalseNoneFalse379236.18250
3956780153364Nonecode28CC BLOCKS 150mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. Sl.No. 6.33, Page No.17, Volume-II GROUND FLOORSqm1292.551292.55308.34FalseNoneNoneFalseNoneFalse398544.8670
3956781153364Nonecode29CC BLOCKS 150mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. Sl.No. 6.33, Page No.17, Volume-II FIRST FLOORSqm1305.481305.48486.89FalseNoneNoneFalseNoneFalse635625.15720
3956782153364Nonecode30CC BLOCKS 150mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. Sl.No. 6.33, Page No.17, Volume-II SECOND FLOORSqm1318.531318.53486.89FalseNoneNoneFalseNoneFalse641979.07170
3956783153364Nonecode31CC BLOCKS 150mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. Sl.No. 6.33, Page No.17, Volume-II THIRD FLOORSqm1331.721331.72486.89FalseNoneNoneFalseNoneFalse648401.15080
3956784153364Nonecode32CC BLOCKS 150mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. Sl.No. 6.33, Page No.17, Volume-II FOURTH FLOORSqm1345.031345.03486.89FalseNoneNoneFalseNoneFalse654881.65670
3956785153364Nonecode33CC BLOCKS 150mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x150x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications.. Sl.No. 6.33, Page No.17, Volume-II HEAD ROOM DOORSqm1358.481358.48159.94FalseNoneNoneFalseNoneFalse217275.29120
3956786153364Nonecode34CC BLOCKS 100mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.34, Page No.17, Volume-II GROUND FLOORSqm1159.21159.248.62FalseNoneNoneFalseNoneFalse56360.3040
3956787153364Nonecode35CC BLOCKS 100mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.34, Page No.17, Volume-II FIRST FLOORSqm1170.791170.7997.23FalseNoneNoneFalseNoneFalse113835.91170
3956788153364Nonecode36CC BLOCKS 100mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.34, Page No.17, Volume-II SECOND FLOORSqm1182.51182.597.23FalseNoneNoneFalseNoneFalse114974.4750
3956789153364Nonecode37CC BLOCKS 100mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.34, Page No.17, Volume-II THIRD FLOORSqm1194.321194.3297.23FalseNoneNoneFalseNoneFalse116123.73360
3956790153364Nonecode38CC BLOCKS 100mm Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. Sl.No. 6.34, Page No.17, Volume-II FOURTH FLOORSqm1206.271206.2797.23FalseNoneNoneFalseNoneFalse117285.63210
3956791153364Nonecode39RCC M25 FOR LINTEL Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I GROUND FLOORCum11496.2411496.247.73FalseNoneNoneFalseNoneFalse88865.93520
3956792153364Nonecode40RCC M25 FOR LINTEL Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FIRST FLOORCum11611.211611.211.08FalseNoneNoneFalseNoneFalse128652.0960
3956793153364Nonecode41RCC M25 FOR LINTEL Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I SECOND FLOORCum11727.3111727.3111.08FalseNoneNoneFalseNoneFalse129938.59480
3956794153364Nonecode42RCC M25 FOR LINTEL Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I THIRD FLOORCum11844.5911844.5911.08FalseNoneNoneFalseNoneFalse131238.05720
3956795153364Nonecode43RCC M25 FOR LINTEL Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FOURTH FLOORCum11963.0311963.0311.08FalseNoneNoneFalseNoneFalse132550.37240
3956796153364Nonecode44RCC M25 FOR LINTEL Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I HEAD ROOM DOORCum12082.6612082.660.98FalseNoneNoneFalseNoneFalse11841.00680
3956797153364Nonecode45CC M15 FOR CILL Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 45% ON CONCRETE ITEM) SL NO.2.1.4 PAGE NO. 15 VOLUME-I GROUND FLOORCum9465.389465.383.75FalseNoneNoneFalseNoneFalse35495.1750
3956798153364Nonecode46CC M15 FOR CILL Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 45% ON CONCRETE ITEM) SL NO.2.1.4 PAGE NO. 15 VOLUME-I FIRST FLOORCum9560.049560.045.82FalseNoneNoneFalseNoneFalse55639.43280
3956799153364Nonecode47CC M15 FOR CILL Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 45% ON CONCRETE ITEM) SL NO.2.1.4 PAGE NO. 15 VOLUME-I SECOND FLOORCum9655.649655.645.82FalseNoneNoneFalseNoneFalse56195.82480
3956800153364Nonecode48CC M15 FOR CILL Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 45% ON CONCRETE ITEM) SL NO.2.1.4 PAGE NO. 15 VOLUME-I THIRD FLOORCum9752.199752.195.82FalseNoneNoneFalseNoneFalse56757.74580
3956801153364Nonecode49CC M15 FOR CILL Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 45% ON CONCRETE ITEM) SL NO.2.1.4 PAGE NO. 15 VOLUME-I FOURTH FLOORCum9849.719849.715.82FalseNoneNoneFalseNoneFalse57325.31220
3956802153364Nonecode50CC M15 FOR CILL Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications.)-- Mix 1:3:6 Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 45% ON CONCRETE ITEM) SL NO.2.1.4 PAGE NO. 15 VOLUME-I HEAD ROOM DOORCum9948.219948.210.49FalseNoneNoneFalseNoneFalse4874.62290
3956803153364Nonecode51RCC M25 FOR ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I GROUND FLOORCum11496.2411496.2441.57FalseNoneNoneFalseNoneFalse477898.69680
3956804153364Nonecode52RCC M25 FOR ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FIRST FLOORCum11611.211611.248.13FalseNoneNoneFalseNoneFalse558847.0560
3956805153364Nonecode53RCC M25 FOR ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I SECOND FLOORCum11727.3111727.3148.13FalseNoneNoneFalseNoneFalse564435.43030
3956806153364Nonecode54RCC M25 FOR ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I THIRD FLOORCum11844.5911844.5948.13FalseNoneNoneFalseNoneFalse570080.11670
3956807153364Nonecode55RCC M25 FOR ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FOURTH FLOORCum11963.0311963.0348.13FalseNoneNoneFalseNoneFalse575780.63390
3956808153364Nonecode56RCC M25 FOR ROOF BEAM Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 60% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I HEAD ROOMCum12082.6612082.662.32FalseNoneNoneFalseNoneFalse28031.77120
3956809153364Nonecode57RCC M25 FOR ROOF SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I Ground floorCum10777.7310777.7380.25FalseNoneNoneFalseNoneFalse864912.83250
3956810153364Nonecode58RCC M25 FOR ROOF SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FIRST FLOORCum10885.510885.578.0FalseNoneNoneFalseNoneFalse849069.00
3956811153364Nonecode59RCC M25 FOR ROOF SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I SECOND FLOORCum10994.3610994.3678.0FalseNoneNoneFalseNoneFalse857560.080
3956812153364Nonecode60RCC M25 FOR ROOF SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I THIRD FLOORCum11104.311104.378.0FalseNoneNoneFalseNoneFalse866135.40
3956813153364Nonecode61RCC M25 FOR ROOF SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FOURTH FLOORCum11215.3411215.3478.0FalseNoneNoneFalseNoneFalse874796.520
3956814153364Nonecode62RCC M25 FOR ROOF SLAB Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I HEAD ROOMCum11327.511327.59.9FalseNoneNoneFalseNoneFalse112142.250
3956815153364Nonecode63RCC M25 FOR STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I GROUND FLOORCum10777.7310777.734.16FalseNoneNoneFalseNoneFalse44835.35680
3956816153364Nonecode64RCC M25 FOR STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FIRST FLOORCum10885.510885.54.16FalseNoneNoneFalseNoneFalse45283.680
3956817153364Nonecode65RCC M25 FOR STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I SECOND FLOORCum10994.3610994.364.16FalseNoneNoneFalseNoneFalse45736.53760
3956818153364Nonecode66RCC M25 FOR STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I THIRD FLOORCum11104.311104.34.16FalseNoneNoneFalseNoneFalse46193.8880
3956819153364Nonecode67RCC M25 FOR STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I FOURTH FLOORCum11215.3411215.344.16FalseNoneNoneFalseNoneFalse46655.81440
3956820153364Nonecode68RCC M25 FOR STAIRCASE Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 50% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-I HEAD ROOMCum11327.511327.54.16FalseNoneNoneFalseNoneFalse47122.40
3956821153364Nonecode69TMT STEELS Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Sl. No. 2.11,a Page No.18 Volume-I GROUND FLOORTonne93929.8593929.8553.27FalseNoneNoneFalseNoneFalse5003643.10950
3956822153364Nonecode70TMT STEELS Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Sl. No. 2.11,a Page No.18 Volume-I FIRST FLOORTonne94869.1594869.1523.78FalseNoneNoneFalseNoneFalse2255988.3870
3956823153364Nonecode71TMT STEELS Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Sl. No. 2.11,a Page No.18 Volume-I SECOND FLOORTonne95817.8495817.8423.78FalseNoneNoneFalseNoneFalse2278548.23520
3956824153364Nonecode72TMT STEELS Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Sl. No. 2.11,a Page No.18 Volume-I THIRD FLOORTonne96776.0296776.0223.78FalseNoneNoneFalseNoneFalse2301333.75560
3956825153364Nonecode73TMT STEELS Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Sl. No. 2.11,a Page No.18 Volume-I FOURTH FLOORTonne97743.7897743.7823.78FalseNoneNoneFalseNoneFalse2324347.08840
3956826153364Nonecode74TMT STEELS Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification Sl. No. 2.11,a Page No.18 Volume-I HEAD ROOMTonne98721.2298721.222.83FalseNoneNoneFalseNoneFalse279381.05260
3956827153364Nonecode75FRAME FOR MAIN DOOR Providing Red Salwood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps), but including cost of materials, labour, usage charges complete as per specifications.section Sl. No. 12.13.2 Page No. 100, Volume-IIm104580.0104580.00.46FalseNoneNoneFalseNoneFalse48106.80
3956828153364Nonecode76SHUTTER FOR MAIN DOOR Providing and fixing in position fully panelled Matti/Nandi wood shutters for doors with, stiles and rails of 35mm. thick with bottom and lock rails 180mm wide top rail and stiles 100mm wide as per drawing and panels of 25mm thick including cost of materials, labour, usage charges complete as per specifications. (excluding cost of fixtures ) Sl. No. 12.18. Page No. 100, Volume-IISqm6904.86904.811.28FalseNoneNoneFalseNoneFalse77886.1440
3956829153364Nonecode77WPC FRAME FOR INTERNAL DOORS Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Sl.No 12.93. 1Page No111 Volume- II GROUND FLOORm737.1737.160.0FalseNoneNoneFalseNoneFalse44226.00
3956830153364Nonecode78WPC FRAME FOR INTERNAL DOORS Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Sl.No 12.93. 1Page No111 Volume- II FIRST FLOORm744.47744.4790.0FalseNoneNoneFalseNoneFalse67002.30
3956831153364Nonecode79WPC FRAME FOR INTERNAL DOORS Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Sl.No 12.93. 1Page No111 Volume- II SECOND FLOORm751.92751.9290.0FalseNoneNoneFalseNoneFalse67672.80
3956832153364Nonecode80WPC FRAME FOR INTERNAL DOORS Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Sl.No 12.93. 1Page No111 Volume- II THIRD FLOORm759.43759.4390.0FalseNoneNoneFalseNoneFalse68348.70
3956833153364Nonecode81WPC FRAME FOR INTERNAL DOORS Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Sl.No 12.93. 1Page No111 Volume- II FOURTH FLOORm767.03767.0390.0FalseNoneNoneFalseNoneFalse69032.70
3956834153364Nonecode82WPC FRAME FOR INTERNAL DOORS Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window/Clerestory windows & other Frames/ Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/ wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Sl.No 12.93. 1Page No111 Volume- II HEAD ROOMm767.03767.036.0FalseNoneNoneFalseNoneFalse4602.180
3956835153364Nonecode83WPC SHUTTER FOR OTHER DOOR Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately). Sl. No. 12.95. Page No. 112, Volume-II GROUND FLOORSqm4631.554631.5521.96FalseNoneNoneFalseNoneFalse101708.8380
3956836153364Nonecode84WPC SHUTTER FOR OTHER DOOR Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately). Sl. No. 12.95. Page No. 112, Volume-II FIRST FLOORSqm4677.874677.8728.35FalseNoneNoneFalseNoneFalse132617.61450
3956837153364Nonecode85WPC SHUTTER FOR OTHER DOOR Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately). Sl. No. 12.95. Page No. 112, Volume-II SECOND FLOORSqm4724.644724.6428.35FalseNoneNoneFalseNoneFalse133943.5440
3956838153364Nonecode86WPC SHUTTER FOR OTHER DOOR Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately). Sl. No. 12.95. Page No. 112, Volume-II THIRD FLOORSqm4771.894771.8928.35FalseNoneNoneFalseNoneFalse135283.08150
3956839153364Nonecode87WPC SHUTTER FOR OTHER DOOR Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately). Sl. No. 12.95. Page No. 112, Volume-II FOURTH FLOORSqm4819.614819.6128.35FalseNoneNoneFalseNoneFalse136635.94350
3956840153364Nonecode88WPC SHUTTER FOR OTHER DOOR Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white colour board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-incharge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin Polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing as per requirement at site with necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately). Sl. No. 12.95. Page No. 112, Volume-II HEAD ROOMSqm4867.814867.811.89FalseNoneNoneFalseNoneFalse9200.16090
3956841153364Nonecode89UPVC DOOR FRAME FOR BATHROOM Providing and fixing factory made uPVC door frame made of uPVCextruded sections having an overall dimension as below (tolerance +/- 1mm), with wall thickness 2.0 mm (+/- 0.2 mm), corners of the door frameto be Jointed with galvanized brackets and stainless steel screws, jointsmitred and Plastic welded. The hinge side vertical of theframes reinforcedby galvanized M.S. tube of size 19 X 19 mm and 1mm (+/- 0.1 mm) wallthickness and 3nos. stainless steel hinges fixed to the frame completeas per manufacturer’s specification and direction of Engineer- in-charge 42x50 mm PVC Extruded section Sl. No. 12.83.2 Page No. 108, Volume-II Ground floorm246.17246.1762.7FalseNoneNoneFalseNoneFalse15434.8590
3956842153364Nonecode90UPVC DOOR FRAME FOR BATHROOM Providing and fixing factory made uPVC door frame made of uPVCextruded sections having an overall dimension as below (tolerance +/- 1mm), with wall thickness 2.0 mm (+/- 0.2 mm), corners of the door frameto be Jointed with galvanized brackets and stainless steel screws, jointsmitred and Plastic welded. The hinge side vertical of theframes reinforcedby galvanized M.S. tube of size 19 X 19 mm and 1mm (+/- 0.1 mm) wallthickness and 3nos. stainless steel hinges fixed to the frame completeas per manufacturer’s specification and direction of Engineer- in-charge 42x50 mm PVC Extruded section Sl. No. 12.83.2 Page No. 108, Volume-II First Floorm248.63248.63125.4FalseNoneNoneFalseNoneFalse31178.2020
3956843153364Nonecode91UPVC DOOR FRAME FOR BATHROOM Providing and fixing factory made uPVC door frame made of uPVCextruded sections having an overall dimension as below (tolerance +/- 1mm), with wall thickness 2.0 mm +/- 0.2 mm), corners of the door frameto be Jointed with galvanized brackets and stainless steel screws, jointsmitred and Plastic welded. The hinge side vertical of theframes reinforcedby galvanized M.S. tube of size 19 X 19 mm and 1mm (+/- 0.1 mm) wallthickness and 3nos. stainless steel hinges fixed to the frame completeas per manufacturer’s specification and direction of Engineer- in-charge 42x50 mm PVC Extruded section Sl. No. 12.83.2 Page No. 108, Volume-II SECOND FLOORm251.12251.12125.4FalseNoneNoneFalseNoneFalse31490.4480
3956844153364Nonecode92UPVC DOOR FRAME FOR BATHROOM Providing and fixing factory made uPVC door frame made of uPVCextruded sections having an overall dimension as below (tolerance +/- 1mm), with wall thickness 2.0 mm (+/- 0.2 mm), corners of the door frameto be Jointed with galvanized brackets and stainless steel screws, jointsmitred and Plastic welded. The hinge side vertical of theframes reinforcedby galvanized M.S. tube of size 19 X 19 mm and 1mm (+/- 0.1 mm) wallthickness and 3nos. stainless steel hinges fixed to the frame completeas per manufacturer’s specification and direction of Engineer- in-charge 42x50 mm PVC Extruded section Sl. No. 12.83.2 Page No. 108, Volume-II THIRD FLOORm253.63253.63125.4FalseNoneNoneFalseNoneFalse31805.2020
3956845153364Nonecode93UPVC DOOR FRAME FOR BATHROOM Providing and fixing factory made uPVC door frame made of uPVCextruded sections having an overall dimension as below (tolerance +/- 1mm), with wall thickness 2.0 mm (+/- 0.2 mm), corners of the door frameto be Jointed with galvanized brackets and stainless steel screws, jointsmitred and Plastic welded. The hinge side vertical of theframes reinforcedby galvanized M.S. tube of size 19 X 19 mm and 1mm (+/- 0.1 mm) wallthickness and 3nos. stainless steel hinges fixed to the frame completeas per manufacturer’s specification and direction of Engineer- in-charge 42x50 mm PVC Extruded section Sl. No. 12.83.2 Page No. 108, Volume-II FOURTH FLOORm256.17256.17125.4FalseNoneNoneFalseNoneFalse32123.7180
3956846153364Nonecode94UPVC DOOR SHUTTERS FOR BATHROOM Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made Sl. No. 12.92 Page No. 111, Volume-II Ground floorSqm6432.356432.3517.33FalseNoneNoneFalseNoneFalse111472.62550
3956847153364Nonecode95UPVC DOOR SHUTTERS FOR BATHROOM Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made Sl. No. 12.92 Page No. 111, Volume-II FIRST FLOORSqm6496.676496.6734.65FalseNoneNoneFalseNoneFalse225109.61550
3956848153364Nonecode96UPVC DOOR SHUTTERS FOR BATHROOM Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made Sl. No. 12.92 Page No. 111, Volume-II SECOND FLOORSqm6561.646561.6434.65FalseNoneNoneFalseNoneFalse227360.8260
3956849153364Nonecode97UPVC DOOR SHUTTERS FOR BATHROOM Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made Sl. No. 12.92 Page No. 111, Volume-II THIRD FLOORSqm6627.266627.2634.65FalseNoneNoneFalseNoneFalse229634.5590
3956850153364Nonecode98UPVC DOOR SHUTTERS FOR BATHROOM Providing& fixing of Openable door made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPV(Thermo Plastic Vulcanized) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the openable frame. The frame having overall size of 60mm x 55mm with GI reinforcement of 1mm thickness and openable sash with overall size of 60mm x 102mm and GI reinforcement of 2mm thickness. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 34 mm. Windows shall be provided with 6mm plain float glass, Standard hardware with 2D/3D hinge & Multi point locking system with Handle. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 900mm x 2400mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made Sl. No. 12.92 Page No. 111, Volume-II FOURTH FLOORSqm6693.536693.5334.65FalseNoneNoneFalseNoneFalse231930.81450
3956851153364Nonecode99HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge Sl. No.22.15.2,Page No. 218 Volume-II SS Handles 300mm GROUND FloorNo566.5566.510.0FalseNoneNoneFalseNoneFalse5665.00
3956852153364Nonecode100HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge Sl. No.22.15.2,Page No. 218 Volume-II SS Handles 300mm First FloorNo566.5566.516.0FalseNoneNoneFalseNoneFalse9064.00
3956853153364Nonecode101HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge Sl. No.22.15.2,Page No. 218 Volume-II SS Handles 300mm SECOND FLOORNo566.5566.516.0FalseNoneNoneFalseNoneFalse9064.00
3956854153364Nonecode102HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge Sl. No.22.15.2,Page No. 218 Volume-II SS Handles 300mm THIRD FLOORNo566.5566.516.0FalseNoneNoneFalseNoneFalse9064.00
3956855153364Nonecode103HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charge Sl. No.22.15.2,Page No. 218 Volume-II SS Handles 300mm FOURTH FLOORNo566.5566.516.0FalseNoneNoneFalseNoneFalse9064.00
3956856153364Nonecode104HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Aldrop 16mm dia, 300mm Sl. No.22.15.4,Page No. 218 Volume-II GROUND FloorNo386.25386.2518.0FalseNoneNoneFalseNoneFalse6952.50
3956857153364Nonecode105HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Aldrop 16mm dia, 300mm Sl. No.22.15.4,Page No. 218 Volume-II First FloorNo390.11390.1130.0FalseNoneNoneFalseNoneFalse11703.30
3956858153364Nonecode106HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Aldrop 16mm dia, 300mm Sl. No.22.15.4,Page No. 218 Volume-II SECOND FLOORNo390.11390.1130.0FalseNoneNoneFalseNoneFalse11703.30
3956859153364Nonecode107HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Aldrop 16mm dia, 300mm Sl. No.22.15.4,Page No. 218 Volume-II THIRD FLOORNo390.11390.1130.0FalseNoneNoneFalseNoneFalse11703.30
3956860153364Nonecode108HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Aldrop 16mm dia, 300mm Sl. No.22.15.4,Page No. 218 Volume-II FOURTH FLOORNo390.11390.1130.0FalseNoneNoneFalseNoneFalse11703.30
3956861153364Nonecode109HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Tower Bolts 250x10mm Sl. No.22.15.7,Page No. 218 Volume-II GROUND FloorNo206.0206.018.0FalseNoneNoneFalseNoneFalse3708.00
3956862153364Nonecode110HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Tower Bolts 250x10mm Sl. No.22.15.7,Page No. 218 Volume-II First FloorNo208.06208.0630.0FalseNoneNoneFalseNoneFalse6241.80
3956863153364Nonecode111HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Tower Bolts 250x10mm Sl. No.22.15.7,Page No. 218 Volume-II SECOND FLOORNo208.06208.0630.0FalseNoneNoneFalseNoneFalse6241.80
3956864153364Nonecode112HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Tower Bolts 250x10mm Sl. No.22.15.7,Page No. 218 Volume-II THIRD FLOORNo208.06208.0630.0FalseNoneNoneFalseNoneFalse6241.80
3956865153364Nonecode113HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Tower Bolts 250x10mm Sl. No.22.15.7,Page No. 218 Volume-II FOURTH FLOORNo208.06208.0630.0FalseNoneNoneFalseNoneFalse6241.80
3956866153364Nonecode114HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS hinges 100 mm Sl. No.22.15.9,Page No. 218 Volume-II GROUND FloorNo72.172.118.0FalseNoneNoneFalseNoneFalse1297.80
3956867153364Nonecode115HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS hinges 100 mm Sl. No.22.15.9,Page No. 218 Volume-II First FloorNo72.8272.8230.0FalseNoneNoneFalseNoneFalse2184.60
3956868153364Nonecode116HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS hinges 100 mm Sl. No.22.15.9,Page No. 218 Volume-II SECOND FLOORNo72.8272.8230.0FalseNoneNoneFalseNoneFalse2184.60
3956869153364Nonecode117HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS hinges 100 mm Sl. No.22.15.9,Page No. 218 Volume-II THIRD FLOORNo72.8272.8230.0FalseNoneNoneFalseNoneFalse2184.60
3956870153364Nonecode118HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS hinges 100 mm Sl. No.22.15.9,Page No. 218 Volume-II FOURTH FLOORNo72.8272.8230.0FalseNoneNoneFalseNoneFalse2184.60
3956871153364Nonecode119HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Door stopper 75mm Sl. No.22.15.10.Page No. 218 Volume-II GROUND FloorNo103.0103.09.0FalseNoneNoneFalseNoneFalse927.00
3956872153364Nonecode120HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Door stopper 75mm Sl. No.22.15.10.Page No. 218 Volume-II First FloorNo104.03104.0315.0FalseNoneNoneFalseNoneFalse1560.450
3956873153364Nonecode121HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Door stopper 75mm Sl. No.22.15.10.Page No. 218 Volume-II SECOND FLOORNo104.03104.0315.0FalseNoneNoneFalseNoneFalse1560.450
3956874153364Nonecode122HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Door stopper 75mm Sl. No.22.15.10.Page No. 218 Volume-II THIRD FLOORNo104.03104.0315.0FalseNoneNoneFalseNoneFalse1560.450
3956875153364Nonecode123HARDWARE FOR DOOR Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in charg SS Door stopper 75mm Sl. No.22.15.10.Page No. 218 Volume-II FOURTH FLOORNo104.03104.0315.0FalseNoneNoneFalseNoneFalse1560.450
3956876153364Nonecode124UPVC VENTILATOR Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.85 Page No. 110 Volume-II GROUND FLOORSqm6004.956004.954.32FalseNoneNoneFalseNoneFalse25941.3840
3956877153364Nonecode125UPVC VENTILATOR Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.85 Page No. 110 Volume-II FIRST FLOORSqm6064.86064.88.28FalseNoneNoneFalseNoneFalse50216.5440
3956878153364Nonecode126UPVC VENTILATOR Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.85 Page No. 110 Volume-II SECOND FLOORSqm6125.456125.458.28FalseNoneNoneFalseNoneFalse50718.7260
3956879153364Nonecode127UPVC VENTILATOR Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.85 Page No. 110 Volume-II THIRD FLOORSqm6186.76186.78.28FalseNoneNoneFalseNoneFalse51225.8760
3956880153364Nonecode128UPVC VENTILATOR Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.85 Page No. 110 Volume-II FOURTH FLOORSqm6248.576248.578.28FalseNoneNoneFalseNoneFalse51738.15960
3956881153364Nonecode129GRILLS FOR WINDOWS Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Sl. No. 11.34A Page No. 86, Volume-II GROUND FLOORKg176.4176.41147.2FalseNoneNoneFalseNoneFalse202366.080
3956882153364Nonecode130GRILLS FOR WINDOWS Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Sl. No. 11.34A Page No. 86, Volume-II FIRST FLOORKg178.16178.161096.2FalseNoneNoneFalseNoneFalse195298.9920
3956883153364Nonecode131GRILLS FOR WINDOWS Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Sl. No. 11.34A Page No. 86, Volume-II SECOND FLOORKg179.95179.951096.2FalseNoneNoneFalseNoneFalse197261.190
3956884153364Nonecode132GRILLS FOR WINDOWS Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Sl. No. 11.34A Page No. 86, Volume-II THIRD FLOORKg181.75181.751096.2FalseNoneNoneFalseNoneFalse199234.350
3956885153364Nonecode133GRILLS FOR WINDOWS Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to steel windows by welding Sl. No. 11.34A Page No. 86, Volume-II FOURTH FLOORKg183.56183.561096.2FalseNoneNoneFalseNoneFalse201218.4720
3956886153364Nonecode134UPVC FOR WINDOWS Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.90, Page No. 110 Volume-II GROUND FLOORSqm7070.77070.754.36FalseNoneNoneFalseNoneFalse384363.2520
3956887153364Nonecode135UPVC FOR WINDOWS Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.90, Page No. 110 Volume-II FIRST FLOORSqm7141.417141.4148.6FalseNoneNoneFalseNoneFalse347072.5260
3956888153364Nonecode136UPVC FOR WINDOWS Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.90, Page No. 110 Volume-II SECOND FLOORSqm7212.827212.8248.6FalseNoneNoneFalseNoneFalse350543.0520
3956889153364Nonecode137UPVC FOR WINDOWS Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.90, Page No. 110 Volume-II THIRD FLOORSqm7284.957284.9548.6FalseNoneNoneFalseNoneFalse354048.570
3956890153364Nonecode138UPVC FOR WINDOWS Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.90, Page No. 110 Volume-II FOURTH FLOORSqm7357.87357.848.6FalseNoneNoneFalseNoneFalse357589.080
3956891153364Nonecode139UPVC FOR WINDOWS Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size 2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) Sl. No.12.90, Page No. 110 Volume-II HEAD ROOMSqm7431.387431.382.7FalseNoneNoneFalseNoneFalse20064.7260
3956892153364Nonecode140PUTTY ITEM Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. ceiling Sl.No 8.51 Page No.50 Volume-IISqm105.0105.02229.18FalseNoneNoneFalseNoneFalse234063.90
3956893153364Nonecode141INTERNAL WALL PLASTERING Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42 Volume-II GROUND FLOORSqm384.3384.3986.25FalseNoneNoneFalseNoneFalse379015.8750
3956894153364Nonecode142INTERNAL WALL PLASTERING Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42 Volume-II FIRST FLOORSqm388.5388.51337.84FalseNoneNoneFalseNoneFalse519750.840
3956895153364Nonecode143INTERNAL WALL PLASTERING Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42 Volume-II SECOND FLOORSqm392.39392.391337.84FalseNoneNoneFalseNoneFalse524955.03760
3956896153364Nonecode144INTERNAL WALL PLASTERING Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42 Volume-II THIRD FLOORSqm396.31396.311337.84FalseNoneNoneFalseNoneFalse530199.37040
3956897153364Nonecode145INTERNAL WALL PLASTERING Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42 Volume-II FOURTH FLOORSqm400.27400.271337.84FalseNoneNoneFalseNoneFalse535497.21680
3956898153364Nonecode146INTERNAL WALL PLASTERING Providing 15 mm cement plaster with cement mortar 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement on the rough side of single or half brick wall including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.7, Page No.42 Volume-II HEAD ROOMSqm404.27404.27155.51FalseNoneNoneFalseNoneFalse62868.02770
3956899153364Nonecode147WALL PUTTY FOR ABOVE Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. Sl.No 8.51 Page No.50 Volume-IISqm105.0105.06493.13FalseNoneNoneFalseNoneFalse681778.650
3956900153364Nonecode148ROUGH PLASTERING FOR DADOOING Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41 Volume- II GROUND FLOORSqm309.75309.75196.72FalseNoneNoneFalseNoneFalse60934.020
3956901153364Nonecode149ROUGH PLASTERING FOR DADOOING Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41 Volume- II FIRST FLOORSqm312.85312.85289.96FalseNoneNoneFalseNoneFalse90713.9860
3956902153364Nonecode150ROUGH PLASTERING FOR DADOOING Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41 Volume- II SECOND FLOORSqm315.98315.98289.96FalseNoneNoneFalseNoneFalse91621.56080
3956903153364Nonecode151ROUGH PLASTERING FOR DADOOING Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41 Volume- II THIRD FLOORSqm319.14319.14289.96FalseNoneNoneFalseNoneFalse92537.83440
3956904153364Nonecode152ROUGH PLASTERING FOR DADOOING Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl.No. 8.2.1, Page No.41 Volume- II FOURTH FLOORSqm322.33322.33289.96FalseNoneNoneFalseNoneFalse93462.80680
3956905153364Nonecode153EXTERNAL WALL PLASTERING Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge. Sl. No. 8.9, Page No.42 Volume-II GROUND FLOORSqm404.25404.25428.4FalseNoneNoneFalseNoneFalse173180.70
3956906153364Nonecode154EXTERNAL WALL PLASTERING Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge. Sl. No. 8.9, Page No.42 Volume-II FIRST FLOORSqm408.45408.45428.4FalseNoneNoneFalseNoneFalse174979.980
3956907153364Nonecode155EXTERNAL WALL PLASTERING Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge. Sl. No. 8.9, Page No.42 Volume-II SECOND FLOORSqm412.53412.53428.4FalseNoneNoneFalseNoneFalse176727.8520
3956908153364Nonecode156EXTERNAL WALL PLASTERING Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge. Sl. No. 8.9, Page No.42 Volume-II THIRD FLOORSqm416.66416.66428.4FalseNoneNoneFalseNoneFalse178497.1440
3956909153364Nonecode157EXTERNAL WALL PLASTERING Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge. Sl. No. 8.9, Page No.42 Volume-II FOURTH FLOORSqm420.83420.83428.4FalseNoneNoneFalseNoneFalse180283.5720
3956910153364Nonecode158EXTERNAL WALL PLASTERING Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-incharge. Sl. No. 8.9, Page No.42 Volume-II HEAD ROOMSqm425.03425.03167.63FalseNoneNoneFalseNoneFalse71247.77890
3956911153364Nonecode159LATH PALSTER Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixed with chicken mesh for drop chajja,facia, backing to cup boards including cost of all materials, labour, providing and removing form work usage charges, curing, complete as per specifications. Sl.No8.16.a, Page No.43 Volume-IISqm1299.91299.9327.48FalseNoneNoneFalseNoneFalse425691.2520
3956912153364Nonecode160FLOORING VITRIFIED FLOORING Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile 800x800 mm Sl.No 9.12.3, Page No.60 Volume-II GROUND FLOORSqm1319.851319.85160.92FalseNoneNoneFalseNoneFalse212390.2620
3956913153364Nonecode161FLOORING VITRIFIED FLOORING Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile 800x800 mm Sl.No 9.12.3, Page No.60 Volume-II FIRST FLOORSqm1333.051333.05301.47FalseNoneNoneFalseNoneFalse401874.58350
3956914153364Nonecode162FLOORING VITRIFIED FLOORING Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile 800x800 mm Sl.No 9.12.3, Page No.60 Volume-II SECOND FLOORSqm1346.381346.38301.47FalseNoneNoneFalseNoneFalse405893.17860
3956915153364Nonecode163FLOORING VITRIFIED FLOORING Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile 800x800 mm Sl.No 9.12.3, Page No.60 Volume-II THIRD FLOORSqm1359.841359.84301.47FalseNoneNoneFalseNoneFalse409950.96480
3956916153364Nonecode164FLOORING VITRIFIED FLOORING Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.-- Size of Tile 800x800 mm Sl.No 9.12.3, Page No.60 Volume-II FOURTH FLOORSqm1373.41373.4301.47FalseNoneNoneFalseNoneFalse414038.8980
3956917153364Nonecode165GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Sl.No 9.24, Page No.63 Volume-II GROUND FLOORSqm2994.62994.6273.15FalseNoneNoneFalseNoneFalse817974.990
3956918153364Nonecode166GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Sl.No 9.24, Page No.63 Volume-II FIRST FLOORSqm3024.553024.5594.2FalseNoneNoneFalseNoneFalse284912.610
3956919153364Nonecode167GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Sl.No 9.24, Page No.63 Volume-II SECOND FLOORSqm3054.793054.7994.2FalseNoneNoneFalseNoneFalse287761.2180
3956920153364Nonecode168GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Sl.No 9.24, Page No.63 Volume-II THIRD FLOORSqm3085.343085.3494.2FalseNoneNoneFalseNoneFalse290639.0280
3956921153364Nonecode169GRANITE FLOORING Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent. Sl.No 9.24, Page No.63 Volume-II FOURTH FLOORSqm3116.193116.1994.2FalseNoneNoneFalseNoneFalse293545.0980
3956922153364Nonecode170GRANITE FLOORING FOR STAIRCASE Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.Sl.No 9.30, Page No.64 Volume-II GROUND FLOORSqm5594.45594.421.34FalseNoneNoneFalseNoneFalse119384.4960
3956923153364Nonecode171GRANITE FLOORING FOR STAIRCASE Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.Sl.No 9.30, Page No.64 Volume-II FIRST FLOORSqm5650.345650.3421.34FalseNoneNoneFalseNoneFalse120578.25560
3956924153364Nonecode172GRANITE FLOORING FOR STAIRCASE Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.Sl.No 9.30, Page No.64 Volume-II SECOND FLOORSqm5706.855706.8521.34FalseNoneNoneFalseNoneFalse121784.1790
3956925153364Nonecode173GRANITE FLOORING FOR STAIRCASE Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.Sl.No 9.30, Page No.64 Volume-II THIRD FLOORSqm5763.925763.9221.34FalseNoneNoneFalseNoneFalse123002.05280
3956926153364Nonecode174GRANITE FLOORING FOR STAIRCASE Providing and laying flooring and steps fine machine polished granite stone slabs 20 mm thick on cement mortar bed 1:6, 20 mm thick, and joints finished with cement mortar 1:3 over existing cement concrete bed , including cost of materials, mortar, labour, curing complete as per specifications.Sl.No 9.30, Page No.64 Volume-II FOURTH FLOORSqm5821.565821.5621.34FalseNoneNoneFalseNoneFalse124232.09040
3956927153364Nonecode175HALF NOSING Providing half nosing to the 20mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM of equipment etc., complete as per specification MR Approved rate from MDRS Gangavathi GROUND FLOORm180.0180.046.4FalseNoneNoneFalseNoneFalse8352.00
3956928153364Nonecode176HALF NOSING Providing half nosing to the 20mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM of equipment etc., complete as per specification MR Approved rate from MDRS Gangavathi FIRST FLOORm181.8181.833.6FalseNoneNoneFalseNoneFalse6108.480
3956929153364Nonecode177HALF NOSING Providing half nosing to the 20mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM of equipment etc., complete as per specification MR Approved rate from MDRS Gangavathi SECOND FLOORm183.62183.6233.6FalseNoneNoneFalseNoneFalse6169.6320
3956930153364Nonecode178HALF NOSING Providing half nosing to the 20mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM of equipment etc., complete as per specification MR Approved rate from MDRS Gangavathi THIRD FLOORm185.45185.4533.6FalseNoneNoneFalseNoneFalse6231.120
3956931153364Nonecode179HALF NOSING Providing half nosing to the 20mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM of equipment etc., complete as per specification MR Approved rate from MDRS Gangavathi FOURTH FLOORm187.31187.3133.6FalseNoneNoneFalseNoneFalse6293.6160
3956932153364Nonecode180CERAMIC TILE FLOORING FOR TOILET Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete Sl.No 9.11, Page No.60 Volume-II GROUND FLOORSqm933.45933.4548.0FalseNoneNoneFalseNoneFalse44805.60
3956933153364Nonecode181CERAMIC TILE FLOORING FOR TOILET Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete Sl.No 9.11, Page No.60 Volume-II FIRST FLOORSqm942.78942.7874.0FalseNoneNoneFalseNoneFalse69765.720
3956934153364Nonecode182CERAMIC TILE FLOORING FOR TOILET Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete Sl.No 9.11, Page No.60 Volume-II SECOND FLOORSqm952.21952.2174.0FalseNoneNoneFalseNoneFalse70463.540
3956935153364Nonecode183CERAMIC TILE FLOORING FOR TOILET Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete Sl.No 9.11, Page No.60 Volume-II THIRD FLOORSqm961.73961.7374.0FalseNoneNoneFalseNoneFalse71168.020
3956936153364Nonecode184CERAMIC TILE FLOORING FOR TOILET Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete Sl.No 9.11, Page No.60 Volume-II FOURTH FLOORSqm971.35971.3574.0FalseNoneNoneFalseNoneFalse71879.90
3956937153364Nonecode185CERAMIC TILE DADOODING FOR GLAZED TILE Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71 Volume-II GROUND FLOORSqm1161.31161.3192.78FalseNoneNoneFalseNoneFalse223875.4140
3956938153364Nonecode186CERAMIC TILE DADOODING FOR GLAZED TILE Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71 Volume-II FIRST FLOORSqm1172.911172.91289.96FalseNoneNoneFalseNoneFalse340096.98360
3956939153364Nonecode187CERAMIC TILE DADOODING FOR GLAZED TILE Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71 Volume-II SECOND FLOORSqm1184.641184.64289.96FalseNoneNoneFalseNoneFalse343498.21440
3956940153364Nonecode188CERAMIC TILE DADOODING FOR GLAZED TILE Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71 Volume-II THIRD FLOORSqm1196.491196.49289.96FalseNoneNoneFalseNoneFalse346934.24040
3956941153364Nonecode189CERAMIC TILE DADOODING FOR GLAZED TILE Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer- in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per m2, including pointing in white cement mixed with pigment of matching shade complete. Sl.No 10.14, Page No.71 Volume-II FOURTH FLOORSqm1208.451208.45289.96FalseNoneNoneFalseNoneFalse350402.1620
3956942153364Nonecode190PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II GROUND FLOOR WallsSqm165.9165.9986.25FalseNoneNoneFalseNoneFalse163618.8750
3956943153364Nonecode191PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II GROUND FLOOR CelingSqm165.9165.9434.98FalseNoneNoneFalseNoneFalse72163.1820
3956944153364Nonecode192PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II FIRST FLOOR WallsSqm167.56167.561337.84FalseNoneNoneFalseNoneFalse224168.47040
3956945153364Nonecode193PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II FIRST FLOOR CelingSqm167.56167.56444.8FalseNoneNoneFalseNoneFalse74530.6880
3956946153364Nonecode194PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II SECOND FLOOR WallsSqm169.23169.231337.84FalseNoneNoneFalseNoneFalse226402.66320
3956947153364Nonecode195PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II SECOND FLOOR CelingSqm169.23169.23444.8FalseNoneNoneFalseNoneFalse75273.5040
3956948153364Nonecode196PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II THIRD FLOOR WallsSqm170.93170.931337.84FalseNoneNoneFalseNoneFalse228676.99120
3956949153364Nonecode197PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II THIRD FLOOR CelingSqm170.93170.93444.8FalseNoneNoneFalseNoneFalse76029.6640
3956950153364Nonecode198PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II FOURTH FLOOR WallsSqm172.64172.64155.51FalseNoneNoneFalseNoneFalse26847.24640
3956951153364Nonecode199PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II HEAD ROOM WallsSqm174.36174.36155.51FalseNoneNoneFalseNoneFalse27114.72360
3956952153364Nonecode200PAINTING INTERNAL SURFACES Finishing with Deluxe Multi surface paint system for interiors andexteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 ltr/10 m² over and including one coat of Specialprimer applied @ 0.75 ltr /10 m² with paint of approved quality to givean even shade, after thoroughly brooming the surface to remove all dirt,dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl.No 8.33.1 Page No.46 Volume-II HEAD ROOM CelingSqm174.36174.3615.0FalseNoneNoneFalseNoneFalse2615.40
3956953153364Nonecode201PAINTING EXTERNAL SURFACES(WEATHER PROOF EMULSION PAINTING Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.30 Page No.46 Volume-II Ground floorSqm182.7182.7364.14FalseNoneNoneFalseNoneFalse66528.3780
3956954153364Nonecode202PAINTING EXTERNAL SURFACES(WEATHER PROOF EMULSION PAINTING Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.30 Page No.46 Volume-II First floorSqm184.53184.53364.14FalseNoneNoneFalseNoneFalse67194.75420
3956955153364Nonecode203PAINTING EXTERNAL SURFACES(WEATHER PROOF EMULSION PAINTING Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.30 Page No.46 Volume-II Second floorSqm186.37186.37364.14FalseNoneNoneFalseNoneFalse67864.77180
3956956153364Nonecode204PAINTING EXTERNAL SURFACES(WEATHER PROOF EMULSION PAINTING Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.30 Page No.46 Volume-II Third floorSqm188.24188.24364.14FalseNoneNoneFalseNoneFalse68545.71360
3956957153364Nonecode205PAINTING EXTERNAL SURFACES(WEATHER PROOF EMULSION PAINTING Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.30 Page No.46 Volume-II TFourth floorSqm190.12190.12364.14FalseNoneNoneFalseNoneFalse69230.29680
3956958153364Nonecode206PAINTING EXTERNAL SURFACES(WEATHER PROOF EMULSION PAINTING Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two coat applied @ 1.67 ltr/10 m² over and including priming coat of exterior primer applied @ 2.20 kg/10 m²) with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.30 Page No.46 Volume-II HEAD ROOMSqm192.02192.02142.49FalseNoneNoneFalseNoneFalse27360.92980
3956959153364Nonecode207PAINTING EXTERNAL SURFACES (TEXTURED PAINT) Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.29 Page No.44 Volume-II Ground floorSqm297.15297.1564.26FalseNoneNoneFalseNoneFalse19094.8590
3956960153364Nonecode208PAINTING EXTERNAL SURFACES (TEXTURED PAINT) Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.29 Page No.44 Volume-II First floorSqm300.12300.1264.26FalseNoneNoneFalseNoneFalse19285.71120
3956961153364Nonecode209PAINTING EXTERNAL SURFACES (TEXTURED PAINT) Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.29 Page No.44 Volume-II Second floorSqm303.12303.1264.26FalseNoneNoneFalseNoneFalse19478.49120
3956962153364Nonecode210PAINTING EXTERNAL SURFACES (TEXTURED PAINT) Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.29 Page No.44 Volume-II Third floorSqm306.15306.1564.26FalseNoneNoneFalseNoneFalse19673.1990
3956963153364Nonecode211PAINTING EXTERNAL SURFACES (TEXTURED PAINT) Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.29 Page No.44 Volume-II foruth floorSqm309.22309.2264.26FalseNoneNoneFalseNoneFalse19870.47720
3956964153364Nonecode212PAINTING EXTERNAL SURFACES (TEXTURED PAINT) Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.Sl.No 8.29 Page No.44 Volume-II HEAD ROOMSqm312.31312.3125.14FalseNoneNoneFalseNoneFalse7851.47340
3956965153364Nonecode213SS RAILINGS Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Sl.No 11.28 Page No.85 Volume-II GROUND FLOORKg593.25593.25252.0FalseNoneNoneFalseNoneFalse149499.00
3956966153364Nonecode214SS RAILINGS Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Sl.No 11.28 Page No.85 Volume-II FIRST FLOORKg599.18599.18122.4FalseNoneNoneFalseNoneFalse73339.6320
3956967153364Nonecode215SS RAILINGS Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Sl.No 11.28 Page No.85 Volume-II SECOND FLOORKg605.17605.17122.4FalseNoneNoneFalseNoneFalse74072.8080
3956968153364Nonecode216SS RAILINGS Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Sl.No 11.28 Page No.85 Volume-II THIRD FLOORKg611.23611.23122.4FalseNoneNoneFalseNoneFalse74814.5520
3956969153364Nonecode217SS RAILINGS Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts,bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. Sl.No 11.28 Page No.85 Volume-II FOURTH FLOORKg617.34617.34122.4FalseNoneNoneFalseNoneFalse75562.4160
3956970153364Nonecode218WATER PROOFING Polyurethane based Single Component for New Surface Providing and laying water proofing treatment to the Roof with PU based single component elastomeric pure polyurethane based coating on New terrace/Chajjas/Sunken portion of WC:Bathroom, cold applied PU waterproofing membrane that is highly elastic with elongation greater than 400% and tensile strength greater than 2MPa as per ASTM D412. The waterproofing membrane to be applied in 2coats @ 1.6 kg/m2 to achieve final DFT (Dry Film Thickness) of 1mm including prime coat of epoxy primer @150 g/m2 and protection with 120gsm Geo-textile over the waterproofing membrane. The finished cost to include surface preparation, making coving at Junction, Bore Packing, treatment of construction joints completely as per specification.Sl.No 15.1, Page No.149 Volume-IISqm857.85857.85500.0FalseNoneNoneFalseNoneFalse428925.00
3956971153364Nonecode219CINDER CONCRETE FILLING Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Sl.No 7.18, Page No.23 Volume-II FIRST FLOORSqm2138.852138.8514.6FalseNoneNoneFalseNoneFalse31227.210
3956972153364Nonecode220CINDER CONCRETE FILLING Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Sl.No 7.18, Page No.23 Volume-II SECOND FLOORSqm2160.242160.2414.6FalseNoneNoneFalseNoneFalse31539.5040
3956973153364Nonecode221CINDER CONCRETE FILLING Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Sl.No 7.18, Page No.23 Volume-II THIRD FLOORSqm2181.842181.8414.6FalseNoneNoneFalseNoneFalse31854.8640
3956974153364Nonecode222CINDER CONCRETE FILLING Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications.Sl.No 7.18, Page No.23 Volume-II FOURTH FLOORSqm2203.662203.6614.6FalseNoneNoneFalseNoneFalse32173.4360
3956975153364Nonecode223FLAGGING CONCRETE Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Sl.No 2.1.5, Page No.15 Volume-ICum6156.06156.010.71FalseNoneNoneFalseNoneFalse65930.760
3956976153364Nonecode224NP3 pipes for the Coutyard to Outlet of Water Providing and laying reinforced cement concrete pipe NP3 for culverts on first class bedding of granular material in single row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets Clause 1101.6 750mm dia Sl.No 20.16, Page No.134 Volume-IIIm3501.753501.7510.0FalseNoneNoneFalseNoneFalse35017.50
3956977153364Nonecode225Enamel paint Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.41 Page No. 48, Volume-II GROUND FLOORSqm175.35175.3592.0FalseNoneNoneFalseNoneFalse16132.20
3956978153364Nonecode226Enamel paint Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.41 Page No. 48, Volume-II first FLOORSqm177.1177.197.38FalseNoneNoneFalseNoneFalse17245.9980
3956979153364Nonecode227Enamel paint Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.41 Page No. 48, Volume-II SECOND FLOORSqm178.87178.8797.38FalseNoneNoneFalseNoneFalse17418.36060
3956980153364Nonecode228Enamel paint Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.41 Page No. 48, Volume-II THIRD FLOORSqm180.66180.6697.38FalseNoneNoneFalseNoneFalse17592.67080
3956981153364Nonecode229Enamel paint Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :Two coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.41 Page No. 48, Volume-II THIRD FLOORSqm182.47182.4797.38FalseNoneNoneFalseNoneFalse17768.92860
3956982153364Nonecode230Providing and Applying CFTRI approved two component flexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (1 Liquid: 2 Powder), to the RCC surface like bathroom, toilet, balcony & utility area applied @ 1.7kg/m2 in 2 coats to achieve 1mm DFT, having Elongation at break Greater Than50% as per ASTM D 412, Tensile strength Greater Than1N/ mm2 as per ASTM D 412, Adhesion strength: 0.80 N/mm2 as per ASTM D 4541, crack bridging upto 1mm as per ASTM C 836, Water penetration (5 bar pressure) as per BS EN 12390. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification. Sl. No. 15.10 Page No. 151, Volume-IISqm385.35385.3514.6FalseNoneNoneFalseNoneFalse5626.110
3956983153364Nonecode231Providing and Applying CFTRI approved two component flexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (1 Liquid: 2 Powder), to the RCC surface like bathroom, toilet, balcony & utility area applied @ 1.7kg/m2 in 2 coats to achieve 1mm DFT, having Elongation at break Greater Than50% as per ASTM D 412, Tensile strength Greater Than1N/ mm2 as per ASTM D 412, Adhesion strength: 0.80 N/mm2 as per ASTM D 4541, crack bridging upto 1mm as per ASTM C 836, Water penetration (5 bar pressure) as per BS EN 12390. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification. Sl. No. 15.10 Page No. 151, Volume-IISqm389.2389.214.6FalseNoneNoneFalseNoneFalse5682.320
3956984153364Nonecode232Providing and Applying CFTRI approved two component flexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (1 Liquid: 2 Powder), to the RCC surface like bathroom, toilet, balcony & utility area applied @ 1.7kg/m2 in 2 coats to achieve 1mm DFT, having Elongation at break Greater Than50% as per ASTM D 412, Tensile strength Greater Than1N/ mm2 as per ASTM D 412, Adhesion strength: 0.80 N/mm2 as per ASTM D 4541, crack bridging upto 1mm as per ASTM C 836, Water penetration (5 bar pressure) as per BS EN 12390. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification. Sl. No. 15.10 Page No. 151, Volume-IISqm393.1393.114.6FalseNoneNoneFalseNoneFalse5739.260
3956985153364Nonecode233Providing and Applying CFTRI approved two component flexible polymer modified acrylic cementitious waterproofing coating with a mix ratio of (1 Liquid: 2 Powder), to the RCC surface like bathroom, toilet, balcony & utility area applied @ 1.7kg/m2 in 2 coats to achieve 1mm DFT, having Elongation at break Greater Than50% as per ASTM D 412, Tensile strength Greater Than1N/ mm2 as per ASTM D 412, Adhesion strength: 0.80 N/mm2 as per ASTM D 4541, crack bridging upto 1mm as per ASTM C 836, Water penetration (5 bar pressure) as per BS EN 12390. The finished cost to include surface preparation, making coving of 50 mm X 50mm at all right angles of wall Junction with Polymer Repair Mortar and lay 45 gsm glass fibre mesh over the angle fillet when the first coat in still wet, treatment of cracks completely as per specification. Sl. No. 15.10 Page No. 151, Volume-IISqm397.03397.0314.6FalseNoneNoneFalseNoneFalse5796.6380
3956986153364Nonecode234PLASTER MESH Providing and fixing plaster mesh 200mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment) Ground floorm30.930.9480.56FalseNoneNoneFalseNoneFalse14849.3040
3956987153364Nonecode235PLASTER MESH Providing and fixing plaster mesh 200mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment) First floorm30.930.9710.0FalseNoneNoneFalseNoneFalse21939.00
3956988153364Nonecode236PLASTER MESH Providing and fixing plaster mesh 200mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment) SE floorm30.930.9710.0FalseNoneNoneFalseNoneFalse21939.00
3956989153364Nonecode237PLASTER MESH Providing and fixing plaster mesh 200mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment) Third floorm30.930.9710.0FalseNoneNoneFalseNoneFalse21939.00
3956990153364Nonecode238PLASTER MESH Providing and fixing plaster mesh 200mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120gms per sqm width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. (length of mesh only be measured for payment) FOURTH floorm30.930.9710.0FalseNoneNoneFalseNoneFalse21939.00
3956991153364Nonecode239PLUMBING Providing & fixing Chorinated Poly Venyl Chloride (CPVC) 20 mm dia pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00m spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and cost of cutting chases and making good the same including testing of joints complete. (concealed work including cutting chases and good the walls etc. (P.No.122, vol-2 I.No.13.32.2 of SR 2023-24 ) 20 mm diam397.95397.95250.0FalseNoneNoneFalseNoneFalse99487.50
3956992153364Nonecode240Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc.for : pipes of SN 4, 75mm dia (P.No.114, I.No.10.2.1, vol 5, of SR 2023-24m227.85227.85140.0FalseNoneNoneFalseNoneFalse31899.00
3956993153364Nonecode241EARTH FILLING Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. (P.No.7, I.No.9.10, vol 1, of SR 2023-24Cum279.3279.340.0FalseNoneNoneFalseNoneFalse11172.00
3956994153364Nonecode242Providing and fixing C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931. 20 mm nominal bore (P.No.117, I.No.13.15 of SR 2021-22) (vol-2)No761.25761.2550.0FalseNoneNoneFalseNoneFalse38062.50
3956995153364Nonecode243Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fix tures complete,,including cutting and making good the walls and floors wherever required (P.No.131, I.No.14.2.1, vol 2, of SR 2023-24No5079.95079.950.0FalseNoneNoneFalseNoneFalse253995.00
3956996153364Nonecode244Providing and fixing Health faucet of approved make confirming to ISI specifications at suitable place as per direction of engineer-in- charge ( Rate is inclusive of cost of materials and fixtures, labour and conveyance of materials to work spot complete.) (2 in 1 tap system) ( Market Rate) Approved Rate as MDRS Aralihalli GangavathiNo1260.01260.050.0FalseNoneNoneFalseNoneFalse63000.00
3956997153364Nonecode245Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required: using White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer (P.No.133, I.No.14.7A, vol 2, of SR 2023-24No4327.054327.0550.0FalseNoneNoneFalseNoneFalse216352.50
3956998153364Nonecode246Providing and fixing PVC (S.W.R) Nahani Trap 10cms x 10cms with all fitting arrangements & all necessary accessories complete (P.No.127, I.No.13.59, vol-2 of SR 2023-24)No231.0231.0120.0FalseNoneNoneFalseNoneFalse27720.00
3956999153364Nonecode247Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern I.No. 14.5.1 V-IINo9074.19074.125.0FalseNoneNoneFalseNoneFalse226852.50
3957000153364Nonecode248Providing and fixing CP Brass 15 mm nominal dia Single lever telephonic wall mixer of quality & make as approved by Engineer in charge. (P.No.135, I.No.14.22B, vol-2 of SR 2023-24)No5840.15840.138.0FalseNoneNoneFalseNoneFalse221923.80
3957001153364Nonecode249Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 g. (P.No.119, I.No.13.14, vol-2 of SR 2023-24)No888.3888.340.0FalseNoneNoneFalseNoneFalse35532.00
3957002153364Nonecode250Providing and fixing brass bib cock of approved quality : 15 mm nominal bore (P.No.117, I.No.13.2.1, vol 2, of SR 2023-24No300.3300.340.0FalseNoneNoneFalseNoneFalse12012.00
3957003153364Nonecode251KSRB13-6.3-: Providing and fixing in position brass gate valve with C.I wheel of approved quality (screwed end) 20mm nominal bore including cost of all materials, labour and HOM of equipments with all leads complete as per specifications. Specification (P.No.41, I.No.2.79.1, vol-5 of SR 2023-24)No396.9396.915.0FalseNoneNoneFalseNoneFalse5953.50
3957004153364Nonecode252Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. (P.No.123, I.No.13.34, vol-2 of SR 2023-24)Ltr9.459.4515000.0FalseNoneNoneFalseNoneFalse141750.00
3957005153364Nonecode253EX P Providing & fixing Chorinated Poly Venyl Chloride (CPVC) pipes of 100 mm dia , having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete. (External work) (P.No.123, I.No.13.33.9 vol-2 of SR 2023-24 )m2650.22650.2150.0FalseNoneNoneFalseNoneFalse397530.00
3957006153364Nonecode254Providing & fixing Chorinated Poly Venyl Chloride (CPVC) pipes of 65 mm dia conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete. (External work) (P.No.123, I.No.13.33.7 vol-2 of SR 2023-24 )m1470.01470.0120.0FalseNoneNoneFalseNoneFalse176400.00
3957007153364Nonecode255Providing & fixing Chorinated Poly Venyl Chloride (CPVC) pipes of 50.00 mm dia conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete. (External work) (P.No.123, I.No.13.33.6 , vil-2 of SR 2023-24)m757.05757.05175.0FalseNoneNoneFalseNoneFalse132483.750
3957008153364Nonecode256Providing & fixing Chorinated Poly Venyl Chloride (CPVC) pipes of 40 mm dia conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete. (External work) (P.No.123, I.No.13.33.5 , vol-2 of SR 2023-24)m500.85500.85100.0FalseNoneNoneFalseNoneFalse50085.00
3957009153364Nonecode257Providing & fixing Chorinated Poly Venyl Chloride (CPVC) pipes of 32 mm dia conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete. (External work) (P.No.122, I.No.13.33.4, vol-2 of SR 2023-24 )m390.6390.6150.0FalseNoneNoneFalseNoneFalse58590.00
3957010153364Nonecode258Providing & fixing Chorinated Poly Venyl Chloride (CPVC) pipes of 25 mm dia conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step solvent cement, trenching, refilling and testing of joints complete. (External work) (P.No.122, I.No.13.33.3 , vol-2 of SR 2023-24 )m310.8310.8120.0FalseNoneNoneFalseNoneFalse37296.00
3957011153364Nonecode259Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :-32mm (P.No.117, I.No.13.4.2 , vol-2 of SR 2023-24 )No627.9627.920.0FalseNoneNoneFalseNoneFalse12558.00
3957012153364Nonecode260Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :-50mm (P.No.117, I.No.13.4.4 , vol-2 of SR 2023-24 )No897.75897.7520.0FalseNoneNoneFalseNoneFalse17955.00
3957013153364Nonecode261Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :-65mm (P.No.117, SI.No.13.4.5 , vol-2 of SR 2023-24 )No1481.551481.5520.0FalseNoneNoneFalseNoneFalse29631.00
3957014153364Nonecode262Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) :-80mm (P.No.117, I.No.13.4.6 , vol-2 of SR 2023-24 )No2180.852180.8510.0FalseNoneNoneFalseNoneFalse21808.50
3957015153364Nonecode263Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN 4, 75mm dia.(P.No.114, I.No10.2.1, vol -5 of SR 2023-24)m227.85227.85120.0FalseNoneNoneFalseNoneFalse27342.00
3957016153364Nonecode264Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for: Pipes of SN 4, 110mm dia. (P.No.114, I.No10.2.2, vol -5 of SR 2023-24)m302.4302.4120.0FalseNoneNoneFalseNoneFalse36288.00
3957017153364Nonecode265Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:(P.No.114, I.No10.2.4, 10.2.5 & 10.2.6 vol -5 of PW, P& IWTD SR 2023-24) do with 160mm dia Pipem604.8604.835.0FalseNoneNoneFalseNoneFalse21168.00
3957018153364Nonecode266Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:(P.No.114, I.No10.2.4, 10.2.5 & 10.2.6 vol -5 of PW, P& IWTD SR 2023-24) do with 200mm dia Pipem872.55872.5525.0FalseNoneNoneFalseNoneFalse21813.750
3957019153364Nonecode267Supplying UNPLASTICISED PVC pipes conforming to IS 16098:2013 with latest amendments ended with integral sockets with ISI mark and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading and unloading at both destinations and cuts of pipes wherever necessary including jointing of UPVC pipes (with cost of elastomeric sealing rings) and specials (excluding cost of specials) with jointing of approved type, with all labour, lead & lifts, including encasing the pipes alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (contractor will make his own arrangements for procuring water for testing) etc. for:(P.No.114, I.No10.2.4, 10.2.5 & 10.2.6 vol -5 of PW, P& IWTD SR 2023-24) do with 250mm dia Pipem1337.71337.725.0FalseNoneNoneFalseNoneFalse33442.50
3957020153364Nonecode268Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata.All kinds of soils. Depth upto 1.50 m (P.No.10, I.No.1.17.1-(Vol-1) of SR 2023-24)Cum275.1275.112.15FalseNoneNoneFalseNoneFalse3342.4650
3957021153364Nonecode269Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover (P.No.190, I.No. 16.10 of SR 2023-24) (vol-5)No4447.84447.85.0FalseNoneNoneFalseNoneFalse22239.00
3957022153364Nonecode270Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. (P.No.190, I.No. 16.9 of SR 2023-24) (vol-5)No5726.75726.75.0FalseNoneNoneFalseNoneFalse28633.50
3957023153364Nonecode271Constructing brick masonry chamber of internal dimension 450x450mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover.. (P.No.191, I.No. 16.10 of SR 2023-24) (vol-5)No4447.84447.83.0FalseNoneNoneFalseNoneFalse13343.40
3957024153364Nonecode272Providing and fixing Pressure relief valve suitable for 40 mm dia pipe at 7th floor to reduce pressure due to head , including cost of all accessories ,labour charges etc. complete as directed by engineer in charge. Market Rate Approved rate from MDRS GangavathiNo12600.012600.05.0FalseNoneNoneFalseNoneFalse63000.00
3957025153364Nonecode273Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Short point up to 3Mtr from tapping point to out let via switchNo282.45282.4510.0FalseNoneNoneFalseNoneFalse2824.50
3957026153364Nonecode274Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Medium point above 3Mtr up to 6Mtr from tapping point to out let via switchNo397.95397.95250.0FalseNoneNoneFalseNoneFalse99487.50
3957027153364Nonecode275Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Long point above 6Mtr up to 10Mtr from tapping point to out let via switchNo582.75582.75120.0FalseNoneNoneFalseNoneFalse69930.00
3957028153364Nonecode276Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Two outlet in a row, above 3Mtr up to 6Mtr from tapping point to out let via switchesNo710.85710.8530.0FalseNoneNoneFalseNoneFalse21325.50
3957029153364Nonecode277Point wiring using Copper wire without switch. Supplying and wiring adopting loop system in existing PVC Conduit /casing capping casing capping using 2x1.5Sqmm (Phase & Neutral) & 1x1.0 sqmm (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS-694: and latest amendments) without control switch shall be fixed on the existing plastic sheet/ gang box, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block. complete for each outlet. Three outlet in a row, above 6Mts up to 10Mtr from tapping point to out let via switchesNo1038.451038.4515.0FalseNoneNoneFalseNoneFalse15576.750
3957030153364Nonecode278Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 1-2WayNo144.9144.9120.0FalseNoneNoneFalseNoneFalse17388.00
3957031153364Nonecode279Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 3WayNo166.95166.95500.0FalseNoneNoneFalseNoneFalse83475.00
3957032153364Nonecode280Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 4-5WayNo185.85185.856.0FalseNoneNoneFalseNoneFalse1115.10
3957033153364Nonecode281Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 6WayNo231.0231.06.0FalseNoneNoneFalseNoneFalse1386.00
3957034153364Nonecode282Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 8 WayNo274.05274.0590.0FalseNoneNoneFalseNoneFalse24664.50
3957035153364Nonecode283Supplying and flush mounting powder coated / galvanized metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in Brick/Stone/C.C wall 10-12WayNo334.95334.9510.0FalseNoneNoneFalseNoneFalse3349.50
3957036153364Nonecode284Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 1 to 2 ModuleNo143.85143.85150.0FalseNoneNoneFalseNoneFalse21577.50
3957037153364Nonecode285Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 3 ModuleNo169.05169.05500.0FalseNoneNoneFalseNoneFalse84525.00
3957038153364Nonecode286Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 4 ModuleNo183.75183.756.0FalseNoneNoneFalseNoneFalse1102.50
3957039153364Nonecode287Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 6 ModuleNo245.7245.76.0FalseNoneNoneFalseNoneFalse1474.20
3957040153364Nonecode288Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 8 ModuleNo298.2298.290.0FalseNoneNoneFalseNoneFalse26838.00
3957041153364Nonecode289Supplying and fixing superior quality modular switch mounting polycarbonate plate with necessary supporting back plate with required nos. of machine screws, bolts nuts etc., complete on the existing metal/PVC box. 10-12 ModuleNo361.2361.215.0FalseNoneNoneFalseNoneFalse5418.00
3957042153364Nonecode290Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps one way SwitchNo107.1107.1700.0FalseNoneNoneFalseNoneFalse74970.00
3957043153364Nonecode291Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps Two way SwitchNo174.3174.310.0FalseNoneNoneFalseNoneFalse1743.00
3957044153364Nonecode292Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6Amps 3way socketNo179.55179.55430.0FalseNoneNoneFalseNoneFalse77206.50
3957045153364Nonecode293Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. Stepped Fan Regulator.No374.85374.85120.0FalseNoneNoneFalseNoneFalse44982.00
3957046153364Nonecode294Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 32Amps DP switchNo342.3342.35.0FalseNoneNoneFalseNoneFalse1711.50
3957047153364Nonecode295Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 6/16Amps universal socketNo247.8247.855.0FalseNoneNoneFalseNoneFalse13629.00
3957048153364Nonecode296Supplying and fixing of modular switch & connected accessories on existing modular switch plate as per IS 3854 and IS 1293. 16Amps one way switchNo189.0189.055.0FalseNoneNoneFalseNoneFalse10395.00
3957049153364Nonecode297Supplyin and Fixing Metal Fan Box with Round Hook.No122.85122.85120.0FalseNoneNoneFalseNoneFalse14742.00
3957050153364Nonecode298Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB).The entire plug and socket shall be mounted in a thermoplastic I powder coated metal box & wired Completely. SP & N 20AmpsNo1019.551019.556.0FalseNoneNoneFalseNoneFalse6117.30
3957051153364Nonecode299Supplying and fixing of Metal Socket set of 2pole and earth plugs and socket for incorporating SP and TP MCB (Without MCB).The entire plug and socket shall be mounted in a thermoplastic I powder coated metal box & wired Completely. TP & N 30AmpsNo1785.01785.03.0FalseNoneNoneFalseNoneFalse5355.00
3957052153364Nonecode300Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thickm69.369.33000.0FalseNoneNoneFalseNoneFalse207900.00
3957053153364Nonecode301Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thickm81.981.9878.0FalseNoneNoneFalseNoneFalse71908.20
3957054153364Nonecode302Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 32mm dia 2.5mm thickm108.15108.1550.0FalseNoneNoneFalseNoneFalse5407.50
3957055153364Nonecode303Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thickm71.471.42000.0FalseNoneNoneFalseNoneFalse142800.00
3957056153364Nonecode304Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thickm82.9582.951500.0FalseNoneNoneFalseNoneFalse124425.00
3957057153364Nonecode305Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 32mm dia 2.5mm thickm103.95103.9560.0FalseNoneNoneFalseNoneFalse6237.00
3957058153364Nonecode306Supplying and fixing sheet Metal box made out of 18 SWG sheet metal with necessary holes for cable/conduit entry as required with one coat of primer of approved make etc.200 x 200 x 65 mmNo365.4365.42.0FalseNoneNoneFalseNoneFalse730.80
3957059153364Nonecode307Supplying and fixing PVC/metal conduit Deep junction box 25 mm deep Junction boxNo58.858.8250.0FalseNoneNoneFalseNoneFalse14700.00
3957060153364Nonecode308Supplying and fixing PVC/metal conduit Deep junction box 32 mm deep Junction boxNo64.0564.05100.0FalseNoneNoneFalseNoneFalse6405.00
3957061153364Nonecode309Supplying PVC flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of thepi pe terminated completely 20mmm19.9519.9530.0FalseNoneNoneFalseNoneFalse598.50
3957062153364Nonecode310Supplying PVC flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of thepi pe terminated completely 25mmm23.123.130.0FalseNoneNoneFalseNoneFalse693.00
3957063153364Nonecode311Supplying PVC flexible conduit pipe…mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300mm using NF screws and on either end of thepi pe terminated completely 32mmm30.4530.4520.0FalseNoneNoneFalseNoneFalse609.00
3957064153364Nonecode312Supplying and drawing Flexible Multicore Cable manufactured with electrolytic grade flexible copper with low conductor confirming to IS 8130-1984 and (Virgin) PVC insulation sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990 -4C x 6 mm2m344.4344.4500.0FalseNoneNoneFalseNoneFalse172200.00
3957065153364Nonecode313Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 1.5 sqmmm27.327.34000.0FalseNoneNoneFalseNoneFalse109200.00
3957066153364Nonecode314Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 2.5 sqmmm44.144.19500.0FalseNoneNoneFalseNoneFalse418950.00
3957067153364Nonecode315Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 4 sqmmm66.1566.151500.0FalseNoneNoneFalseNoneFalse99225.00
3957068153364Nonecode316Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS-694:confirming to latest amendments. 6 sqmmm96.696.6300.0FalseNoneNoneFalseNoneFalse28980.00
3957069153364Nonecode317Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 8 Way TP & NNo6395.556395.5510.0FalseNoneNoneFalseNoneFalse63955.50
3957070153364Nonecode318Supplying and fixing regular MCB distribution boards on wall/ wood board I flush mounting using required clamps,i bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase I 3 phase I single door with powder coated painting. Made out of 14 SWG MS enclosure III - Double Door 12 Way TP & NNo9171.759171.752.0FalseNoneNoneFalseNoneFalse18343.50
3957071153364Nonecode319Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SPNo435.75435.75320.0FalseNoneNoneFalseNoneFalse139440.00
3957072153364Nonecode320Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps DPNo775.95775.9530.0FalseNoneNoneFalseNoneFalse23278.50
3957073153364Nonecode321Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40 Amps DPNo1113.01113.04.0FalseNoneNoneFalseNoneFalse4452.00
3957074153364Nonecode322Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 40Amps TPNNo3196.23196.210.0FalseNoneNoneFalseNoneFalse31962.00
3957075153364Nonecode323Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 16-25 Amps 2 poleNo4490.854490.8530.0FalseNoneNoneFalseNoneFalse134725.50
3957076153364Nonecode324Supplying, fixing and wiring Residual current Circuit Breaker [RCCB] 240/450V up to 300mA sensitivity on existing wood/panel board 63 Amps 4 poleNo5822.255822.2510.0FalseNoneNoneFalseNoneFalse58222.50
3957077153364Nonecode3251.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 4 core 25 sqmmKm188836.2188836.20.2FalseNoneNoneFalseNoneFalse37767.240
3957078153364Nonecode3261.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part 1) or IS-7098 Part-1, 95 Sqmm, 3.5 Core, (21 GI Strips - 4 x 0.8 mm)Km391875.75391875.750.2FalseNoneNoneFalseNoneFalse78375.150
3957079153364Nonecode327Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 35 to 95 SqmmKm32695.9532695.950.2FalseNoneNoneFalseNoneFalse6539.190
3957080153364Nonecode328GI Pipe, 100 mm Dia for drain crossing, cable raising etc.,m1296.751296.7512.0FalseNoneNoneFalseNoneFalse15561.00
3957081153364Nonecode329Brass cable gland 32mm diaNo99.7599.7520.0FalseNoneNoneFalseNoneFalse1995.00
3957082153364Nonecode330Brass cable gland 45mm diaNo206.85206.8530.0FalseNoneNoneFalseNoneFalse6205.50
3957083153364Nonecode331Aluminium end terminal lug 10 sqmmNo2.12.1120.0FalseNoneNoneFalseNoneFalse252.00
3957084153364Nonecode332Aluminium end terminal lug 16 sqmmNo2.12.1120.0FalseNoneNoneFalseNoneFalse252.00
3957085153364Nonecode333Heavy Duty Copper Terminal Long Barrel 70 Sqmm Copper Terminal, Apprx Wt: 38 GmNo147.0147.020.0FalseNoneNoneFalseNoneFalse2940.00
3957086153364Nonecode334Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts.No4468.84468.88.0FalseNoneNoneFalseNoneFalse35750.40
3957087153364Nonecode335Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI stripm86.186.150.0FalseNoneNoneFalseNoneFalse4305.00
3957088153364Nonecode336Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI stripm134.4134.420.0FalseNoneNoneFalseNoneFalse2688.00
3957089153364Nonecode337Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 600x600x3mm GI Plate.No918.75918.754.0FalseNoneNoneFalseNoneFalse3675.00
3957090153364Nonecode338Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm Copper stripm598.5598.550.0FalseNoneNoneFalseNoneFalse29925.00
3957091153364Nonecode339Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. strip 25x6mm Copper stripm1155.01155.050.0FalseNoneNoneFalseNoneFalse57750.00
3957092153364Nonecode340Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm GI strip 600x600x3mm Copper plateNo7792.057792.052.0FalseNoneNoneFalseNoneFalse15584.10
3957093153364Nonecode341Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRIGreater Than 70%. efficacy Greater Than100 lumen per W, 120degree beam spread, lifeGreater Than 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF Greater Than 0.95, power loss shouldLesser Than 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working understandard electrical condition. 10-12WNo1332.451332.455.0FalseNoneNoneFalseNoneFalse6662.250
3957094153364Nonecode342Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRIGreater Than 70%. efficacy Greater Than100 lumen per W, 120degree beam spread, lifeGreater Than 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF Greater Than 0.95, power loss shouldLesser Than 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working understandard electrical condition. 15-18WNo1754.551754.5525.0FalseNoneNoneFalseNoneFalse43863.750
3957095153364Nonecode343Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater Than 80. Power Input: 220-240V @ 50/60Hz & Power factor Greater Than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fighting 1 x2'- 9/10 wNo578.55578.5535.0FalseNoneNoneFalseNoneFalse20249.250
3957096153364Nonecode344Supplying of ......feet - PVC Batten with integrated LED tube .....W with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI Greater Than 80. Power Input: 220-240V @ 50/60Hz & Power factor Greater Than0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. LED light fitting 1 x 4' - 36/40 WNo1332.451332.45300.0FalseNoneNoneFalseNoneFalse399735.00
3957097153364Nonecode345Supplying of recess mounting non integral type ........LED ...... W luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded fase ceiling clamps, Power LEDs with CCT 6500 degree K, CRIGreater Than 70%. efficacy Greater Than100 lumen per watt, 120degree beam spread, lifeGreater Than 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF Greater Than 0.95, power loss should Lesser Than 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, , THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/ CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition.LED modular down light 2'x2' - 36wattNo4780.654780.6520.0FalseNoneNoneFalseNoneFalse95613.00
3957098153364Nonecode346Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT Greater Than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire Greater Than IK08. Power Factor Greater Than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED EfficiencyGreater Than130lm/w, nominal CRI Greater Than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70wattsNo6291.66291.66.0FalseNoneNoneFalseNoneFalse37749.60
3957099153364Nonecode347Supplying of 1440rpm heavy duty exhaust fan with bracket blades suitable to operate on 230V 50Hz, AC Supply complete. 12" Sweep (300mm)No3117.453117.4540.0FalseNoneNoneFalseNoneFalse124698.00
3957100153364Nonecode348Supplying of Ceiling Fan with Capacitor rating As per guideline of BEE 5 star rating and IS:374/19 and also comply with IS: 1709/1984 with latest amendment, Rated voltage 220 V/50 Hz, Rated power upto 35 W +/- 10 %, Rated current As per IS:374/19, Rated power factor 0.9 lagging(min), Rated speed 350 +/- 10% RPM, Rated air delivery 210 +/- 10% Cubic Meter Minimum, Rated service value 6.2 CMM / W, Three Blades of blade leaf 1.05 mm thick Aluminium Alloy sheet, Class B motor insulation, Bearing Two ball bearings, Top 6202, Bottom 6201, as per IS specification, Motor winding. Temp rise Shall not exceed 75 deg C over and ambient of 40 0C by resistance method at 245 V, Insulation resistance Shall not be less than Two Mega Ohms (2M Ohms), Leakage current Should not exceed 210 Micro Amp, Power input, W& current, Air Delivery & Fan Speed as per IS:374/2019 with latest amendment, 2year manufacturer Warranty. (BLDC fans) 56" Sweep 5 Star (1400 mm)No4991.74991.7120.0FalseNoneNoneFalseNoneFalse599004.00
3957101153364Nonecode349Supplying & Fixing of 70-150 Watts lamp holder 2 PinNo66.1566.1520.0FalseNoneNoneFalseNoneFalse1323.00
3957102153364Nonecode350Fixing all types and all capacities of fluorescent / false ceiling / spot light / CFL / LED fittings indoor on the wall / ceiling / rafters / girders using 23/0.0076” twin twisted PVC insulated wires, required Nos of round blocks and clamps. On wall / ceiling / Rafter / GirdersNo128.1128.130.0FalseNoneNoneFalseNoneFalse3843.00
3957103153364Nonecode351Fixing a ceiling / wall mounting fan of all capacities and all types, with necessary clamps and 'S' hook made out of 15mm dia MS rod, with 5 amps. ceiling rose of approved quality with necessary length of 23 / 0.0076 inch PVC insulated twin twisted wire of approved quality, mounted on a suitable size wooden board and wired.No330.75330.75100.0FalseNoneNoneFalseNoneFalse33075.00
3957104153364Nonecode352Fixing one exhaust fan after making a suitable nitch in the wall and finishing with cement mortar and colouring to match the existing wall or brackets, with bolts and nuts and a 5 amps, ceiling rose with sufficient length of 23 / 0.0076 inch PVC insulated twin core wire of approved make with wire mesh and wooden frame.No742.35742.3540.0FalseNoneNoneFalseNoneFalse29694.00
3957105153364Nonecode353Fixing all types and all capacities of 1'x4' / 2'x2' LED Light fittings indoor on the wall / ceiling / rafters / girders with necessary supporting frame, using 2310.0076" twin twisted PVC insulated wires, required Nos of round blocks and clamps.No514.5514.5350.0FalseNoneNoneFalseNoneFalse180075.00
3957106153364Nonecode354Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4” dia telescopic M. S. pipe, with 2” dia 1.5m long M. S. bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 Mtrs. M. S. tubular pole, with necessary two coats of painting, with all other accessories. Single bracket 1.5 Mtr. LengthNo1534.051534.056.0FalseNoneNoneFalseNoneFalse9204.30
3957107153364Nonecode355Supplying and Fixing........mm dia clampsss A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires.Using 32mm dia G.I.PipeNo1359.751359.756.0FalseNoneNoneFalseNoneFalse8158.50
3957108153364Nonecode356Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.No170.1170.16.0FalseNoneNoneFalseNoneFalse1020.60
3957109153364Nonecode357MAIN LT PANEL Fabricating supplying and mounting MS box made out ...SWG suitable for floor I wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete 16SWGSqm0.450.45150000.0FalseNoneNoneFalseNoneFalse67500.00
3957110153364Nonecode358Supplying .........amps rated 3phase with neutral bus bar using required capacity electrolytic aluminum strips covered with heat shrinkable coloured PVC sleeve, mounted on phenoliciFRP/DMC insulator which are mounted on powder coated 40x6mm M.S.flat frame work in existing panel board. The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts, nuts and washers etc., complete. 100 A 4 x 30 x 6 mm Aluminium Stripsm2588.252588.255.0FalseNoneNoneFalseNoneFalse12941.250
3957111153364Nonecode359Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 40x40x6mmm320.25320.2520.0FalseNoneNoneFalseNoneFalse6405.00
3957112153364Nonecode360Supplying and fixing angle iron frame work iabricated out of M.S. angle iron.. and M.S. flat ... with bolts, washers etc.,and painted with 2 coats of red oxide and then two coats of approved paint 50x100x50x6mm C channelm793.8793.820.0FalseNoneNoneFalseNoneFalse15876.00
3957113153364Nonecode361Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SPNo435.75435.755.0FalseNoneNoneFalseNoneFalse2178.750
3957114153364Nonecode362Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32Amps SPNo775.95775.954.0FalseNoneNoneFalseNoneFalse3103.80
3957115153364Nonecode363Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 A TPNNo1802.851802.8512.0FalseNoneNoneFalseNoneFalse21634.20
3957116153364Nonecode364Supplying of multi function digital meter with three line back light LCD type display for voltage, Current, frequency, Power, power factor, KVA, KWH,KVAR suitable for 3 phase, 4 wire LT network with IP 54 degree of protection and completely wired as required with communication Port and Class 0.5s accuracyNo9780.759780.751.0FalseNoneNoneFalseNoneFalse9780.750
3957117153364Nonecode365Supplying and fixing of LED type panel board indicating lamp with required colour suitable for 220v A.C. 50 Hz 12/24v D.CNo540.75540.7510.0FalseNoneNoneFalseNoneFalse5407.50
3957118153364Nonecode366Supplying, fixing and wiring 50/5 to 400/5Amps 15VA burden Current Transformer. Class 0.5 accuracy with Tape WoundNo590.1590.110.0FalseNoneNoneFalseNoneFalse5901.00
3957119153364Nonecode367Supply and fixing of fully Enclosed Automatic Transfer Switch (ATS) Pre-wired with Flexible Settings and seamless transfer between two power sources. The enclosure made of MS Power coated of necessary size. The switch comprising of EB/DG-Priority Source Selection,. Adjustable Time Delay (0.1sec to 3 hours),.Double-Break Contact System offering High Short-time Withstand (Icw),.with necessary Terminal Shrouds, Phase Barriers & Source Separator,. Protections for UV/OV, Phase Sequence, Single Phasing, Frequency variation. There should be sufficient space for cable termination. Three Phase 415 V, 125 ANo77527.877527.81.0FalseNoneNoneFalseNoneFalse77527.80
3957120153364Nonecode368EXTERNAL STREET LIGHTING Fabricating, supplying and erecting swaged tubular pole of height …Mtr having three sections, and providing two coats of red oxide paint and finished with two coats of enamelled paint of approved quality and colour and M.S. base plate of suitable size welded at the bottom of the pole(as per IS) and 40mm dia GI / flexible PVC pipe of 1 mtr length fitted to the heavy gauge polycarbonate control box including 5way connector of size 167x125x82mm for 7.5M pole/200x160x98mm for remaining length of pole with front opening cover, with locking arrangements and suitable capacity MCB / DP switch, The pole shall be erected in cement concrete work (1:2:4) including excavation and refilling of planting depth of the pole to the ground level and the coping CC shall be up to 0.6M above ground level as per IS 2713 - 7. Erection of heavy duty pole on Footpath / median 9Mt (5Mt Hb,165.1mm dia 4.85mm thick x2M Hm, 139.7mm dia 4.50mm thick x 2M Ht,114.3mm dia 3.65mm thick) as per IS 410 SP 32No16275.016275.04.0FalseNoneNoneFalseNoneFalse65100.00
3957121153364Nonecode369Supply of LED Streetlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, maximum light intensity should be between 60 degrees to 70 degrees. CCT Greater Than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire Greater Than IK08. Power Factor Greater Than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mouting with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ........W System Power consumption. LED EfficiencyGreater Than130lm/w, nominal CRI Greater Than75. Luminaire manufacturer should have in-house facility accredited by NABL/CPRI & any Government certified agency & Design & Development facility certified by ISO 9001:2008 . Housing with supplier word mark /name shall be Engraved / Embossing on the die cast housing/ Body part. Warranty of 2 Years against any manufacturing defect working under standard electrical conditions as mentioned above should be given by LED manufacturer & Cree/Nichia/ Lumileds/Osram make LED Source. LED Streetlight 70wattsNo6291.66291.64.0FalseNoneNoneFalseNoneFalse25166.40
3957122153364Nonecode370Supplying and Fixing........mm dia clampsss A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clamps, bolts, nuts and wiring using suitable capacity wires.Using 32mm dia G.I.PipeNo1359.751359.754.0FalseNoneNoneFalseNoneFalse5439.00
3957123153364Nonecode371Supply of LED Bollard light fitting of ...W with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output. Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT Greater Than 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire Greater Than IK08. Power Factor Greater Than0.9 with mains, Surge Protection- Min 5KV along with Over voltage/Overload, short circuit/ miss-wiring protection. Universal Voltage driver to operate wide voltage range from 100V to 270V 50/60Hz application. Compliance to IS 10322/IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB, with 2 years Warranty against any manufacturing defect working under standard electrical condition. 8W 1 Mtr HeightNo4755.44755.44.0FalseNoneNoneFalseNoneFalse19021.60
3957124153364Nonecode372Fixing halogen/metal halide / SVL / IL / LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires.No170.1170.14.0FalseNoneNoneFalseNoneFalse680.40
3957125153364Nonecode373Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898 6-32 Amps DPNo775.95775.953.0FalseNoneNoneFalseNoneFalse2327.850
3957126153364Nonecode374Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nuts and washers etc.,.) 3-120sec setting.No2430.752430.751.0FalseNoneNoneFalseNoneFalse2430.750
3957127153364Nonecode375Supplying and fixing of solar Lux level street light control switch single phase including suitable capacity contactor- 8KWNo12621.012621.01.0FalseNoneNoneFalseNoneFalse12621.00
3957128153364Nonecode376Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 19/20mm dia 2mm thickm69.369.3350.0FalseNoneNoneFalseNoneFalse24255.00
3957129153364Nonecode377Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures. run with 18SWG GI fish wire wherever necessary. 25mm dia 2mm thickm81.981.935.0FalseNoneNoneFalseNoneFalse2866.50
3957130153364Nonecode378Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 19/20mm dia 2mm thickm71.471.445.0FalseNoneNoneFalseNoneFalse3213.00
3957131153364Nonecode379Supplying heavy gauge PVC conduit pipe …….dia ...... mm thick confirming to IS 2509 with suitable size bends, metal/PVC junction boxes adhesive paste etc., by groove cutting in wall and fixing by bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. 25mm dia 2mm thickm82.9582.9545.0FalseNoneNoneFalseNoneFalse3732.750
3957132153364Nonecode380IP DOME CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8*2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm-13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),30M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets.No20200.020200.015.0FalseNoneNoneFalseNoneFalse303000.00
3957133153364Nonecode381IP BULLET CAMERAS-Supplying, installation, testing and commissioning of SITC of 1/2.8*2 Megapixel Progressive CMOS,1920x1080(2MP),2.7mm-13.5mm,F1.4,Motorized, with a min illumination of 0.05lux/F1.4[color,30IRE]0Lux/F1.4(IRon),60M IR distance, BLC/HLC/WDR(120db),min 2streams,compression should be H.265/H. 264H/MJPEG,128GB SD card,ONVIF Profiles,profile G&Q,POE camera,operating temperature of 60 degrees.All the cameras should have CE,FCC,UL,IP66,IK10.The prices should include the necessary mounts and brackets.No21700.021700.03.0FalseNoneNoneFalseNoneFalse65100.00
3957134153364Nonecode382Supplying and drawing UTP-CAT 6E LAN cablem41.841.8800.0FalseNoneNoneFalseNoneFalse33440.00
3957135153364Nonecode383Supply and Installation of 4 TB Survalance Hard Disk The rate shall include all mounting accessories complete as requiredNo14500.014500.01.0FalseNoneNoneFalseNoneFalse14500.00
3957136153364Nonecode384Supply and Installation of 16 Port L2 Managed Poe Switch The rate shall include all mounting accessories complete as requiredNo40250.040250.01.0FalseNoneNoneFalseNoneFalse40250.00
3957137153364Nonecode385Supply and Installation of I/OsNo125.0125.050.0FalseNoneNoneFalseNoneFalse6250.00
3957138153364Nonecode386Supply and Installation of 2 Mtrs Patch Chord The rate shall include all mounting accessories complete as requiredNo225.0225.010.0FalseNoneNoneFalseNoneFalse2250.00
3957139153364Nonecode387Supply and Installation of Quad Face Plate Camera Side With IOS The rate shall include all mounting accessories complete as requiredNo285.0285.010.0FalseNoneNoneFalseNoneFalse2850.00
3957140153364Nonecode388Supply and Installation of 43"LED Monitor The rate shall include all mounting accessories complete as requiredNo60000.060000.01.0FalseNoneNoneFalseNoneFalse60000.00
3957141153364Nonecode389Design,supplying,erectingtestingandcommissioningof-Passenger/Bed-cum passengerhospitalliftwithspeedof1mtrpersecond,variablevoltagevariablefrequencydrive,withorwithoutmachineroomfortheavailablewellsize,operatingat415V3phase50cyclesACsupply,powdercoated/StainlessSteelcarentrancedoorsenclosureswithsuitablecolourvinylflooring,LEDcarillumination,emergencylight,intercomandfanasdesiredbytheuser,centralopening/sideopeningdoorwithorwithoutattendantoperation,7segmentdisplaybuttons,callregisterindicator,firemandrive,SShandrailsinsidecar,fulllengthinfraredcurtainincardoor,automaticrescuedevicewithbatteries,voiceannouncinginregional/internationallanguages,Braillebuttonswithoneyearwarrantyandmaintenancewithnecessaryscaffoldingandminorcivilworkslikefixingofguiderail,counterweightetc.,ThetotalproductandservicesshalladheretoIS14665/2016(withlatestamendments)part/section1to5withregardstogeneralguidelinesoffiresafetyrateddoors,MRLLbeams,pressureswitch,manualchangeoverfordoorsduringemergency,ARDof10timeswithsufficientbatterybackupandstandarddimensionsofchaircaranddooropeningsforallsizesandcapacitiesofliftsincludingfitnesscertificateanddulyobservingallothersafetynormsprescribedandadheretoCPWDspecifications,PCBNorms,NationalElectricityCode(NEC),NBC-2016,IECandKarnatakaStateLifts,EscalatorsandPassengersConveyersAct 2012 and Rules 2014. The Supplier shall be registered in Government Electrical Inspectorate in the State of Karnataka. With Out Machine Room-PC FinishNo1666957.371666957.371.0FalseNoneNoneFalseNoneFalse1666957.370
3957142153364Nonecode390Supply of DP Structure using RCC Pole - 9 Mtr Long, 145 Kg WL (Including Cost of Poles)No21974.421974.42.0FalseNoneNoneFalseNoneFalse43948.80
3957143153364Nonecode391Erection DP Structure using RCC Pole - 9 Mtr Long, 145 Kg WLNo5640.65640.62.0FalseNoneNoneFalseNoneFalse11281.20
3957144153364Nonecode392Supply& erection of 11 kV, 45 KN Polymeric InsulatorNo195.3195.312.0FalseNoneNoneFalseNoneFalse2343.60
3957145153364Nonecode393Supply of Guy Set Complete with No. 15 Strain InsulatorNo1228.51228.53.0FalseNoneNoneFalseNoneFalse3685.50
3957146153364Nonecode394Erection of Guy Set Complete with No. 15 Strain InsulatorNo622.65622.653.0FalseNoneNoneFalseNoneFalse1867.950
3957147153364Nonecode395Supply of Spiral Earth ElectrodeNo250.95250.953.0FalseNoneNoneFalseNoneFalse752.850
3957148153364Nonecode396Erection of Spiral Earth ElectrodeNo97.6597.653.0FalseNoneNoneFalseNoneFalse292.950
3957149153364Nonecode397Supply& fixing of Guy concreting with Boulders, Mud and SandNo262.5262.53.0FalseNoneNoneFalseNoneFalse787.50
3957150153364Nonecode398Supply of Caution/Danger BoardNo157.5157.52.0FalseNoneNoneFalseNoneFalse315.00
3957151153364Nonecode399Fixing of Caution/Danger BoardNo84.084.02.0FalseNoneNoneFalseNoneFalse168.00
3957152153364Nonecode400Supply of Anti Climbing Device (12 Mtr GI Barbed WireNo93.4593.453.0FalseNoneNoneFalseNoneFalse280.350
3957153153364Nonecode401Erection of Anti Climbing Device (12 Mtr GI Barbed WireNo44.144.13.0FalseNoneNoneFalseNoneFalse132.30
3957154153364Nonecode402Supply and fixing of 11 kV, 400 Amps Double Break GOSNo22323.022323.02.0FalseNoneNoneFalseNoneFalse44646.00
3957155153364Nonecode403Fixing of 11 kV, 400 Amps Double Break GOSNo1274.71274.72.0FalseNoneNoneFalseNoneFalse2549.40
3957156153364Nonecode404Supply of H-Frame for mounting GOSNo4548.64548.62.0FalseNoneNoneFalseNoneFalse9097.20
3957157153364Nonecode405fixing of H-Frame for mounting GOSNo339.15339.152.0FalseNoneNoneFalseNoneFalse678.30
3957158153364Nonecode406Supply of DOLO Cut OutNo6165.66165.62.0FalseNoneNoneFalseNoneFalse12331.20
3957159153364Nonecode407Erection of DOLO Cut OutNo248.85248.852.0FalseNoneNoneFalseNoneFalse497.70
3957160153364Nonecode40811KV EXTENSION Supply RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785No7429.87429.82.0FalseNoneNoneFalseNoneFalse14859.60
3957161153364Nonecode409Erection of RCC Pole - 9 Mtr Long, 145 Kg WL as per IS- 785No1829.11829.12.0FalseNoneNoneFalseNoneFalse3658.20
3957162153364Nonecode410Supply of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WLNo678.3678.32.0FalseNoneNoneFalseNoneFalse1356.60
3957163153364Nonecode411Erection of 11 kV, Horizontal Cross Arm with clamps, HTST supports, bolts, nuts and washers for RCC Pole - 9 Mtr Long, 145 Kg WLNo285.6285.62.0FalseNoneNoneFalseNoneFalse571.20
3957164153364Nonecode412Supply and fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod)No215.25215.256.0FalseNoneNoneFalseNoneFalse1291.50
3957165153364Nonecode413Supply and fixing of 11 kV, 45 KN Polymeric InsulatorNo195.3195.36.0FalseNoneNoneFalseNoneFalse1171.80
3957166153364Nonecode414Supply of Guy Set Complete with No. 15 Strain InsulatorNo1228.51228.52.0FalseNoneNoneFalseNoneFalse2457.00
3957167153364Nonecode415Erection of Guy Set Complete with No. 15 Strain InsulatorNo622.65622.652.0FalseNoneNoneFalseNoneFalse1245.30
3957168153364Nonecode416Supply of Rabbit ACSR ConductorKm48545.748545.71.0FalseNoneNoneFalseNoneFalse48545.70
3957169153364Nonecode417Erection of Rabbit ACSR ConductorKm4579.054579.051.0FalseNoneNoneFalseNoneFalse4579.050
3957170153364Nonecode418Supply and fixing of PG Clamps for Rabbit ConductorNo107.1107.115.0FalseNoneNoneFalseNoneFalse1606.50
3957171153364Nonecode419Supply of Spiral Earth ElectrodeNo250.95250.952.0FalseNoneNoneFalseNoneFalse501.90
3957172153364Nonecode420Erection of Spiral Earth ElectrodeNo97.6597.652.0FalseNoneNoneFalseNoneFalse195.30
3957173153364Nonecode421Supply of EG Stirrups with GI wire lacingNo289.8289.82.0FalseNoneNoneFalseNoneFalse579.60
3957174153364Nonecode422Erection of EG Stirrups with GI wire lacingNo168.0168.02.0FalseNoneNoneFalseNoneFalse336.00
3957175153364Nonecode423Guy concreting with Boulders, Mud and SandNo262.5262.52.0FalseNoneNoneFalseNoneFalse525.00
3957176153364Nonecode424Supply of Caution/Danger BoardNo157.5157.53.0FalseNoneNoneFalseNoneFalse472.50
3957177153364Nonecode425Erection of Caution/Danger BoardNo84.084.03.0FalseNoneNoneFalseNoneFalse252.00
3957178153364Nonecode426Supply of Anti Climbing Device (12 Mtr GI Barbed WireNo93.4593.452.0FalseNoneNoneFalseNoneFalse186.90
3957179153364Nonecode427Erection of Anti Climbing Device (12 Mtr GI Barbed WireNo44.144.12.0FalseNoneNoneFalseNoneFalse88.20
3957180153364Nonecode428Erection of 3 Phase, 11kV/433V, 63 kVA BEE 4/5 Star Rated Distribution Transformer Centre Using DPTS Using PSCC Pole - 9 Mtr Long, 300 Kg WL supplying of DP Transformer Structure using PSCC Pole - 9 Mtr Long, 300 Kg WL (Including Cost of Poles)No29051.429051.41.0FalseNoneNoneFalseNoneFalse29051.40
3957181153364Nonecode429supplying & fixing of 11 kV, 5 KN Polymeric Pin Insulator (24 mm Dia FRP Rod)No215.25215.253.0FalseNoneNoneFalseNoneFalse645.750
3957182153364Nonecode430supplying & fixing of 11 kV, 45 KN Polymeric InsulatorNo195.3195.33.0FalseNoneNoneFalseNoneFalse585.90
3957183153364Nonecode431Supplying of Guy Set Complete with No. 15 Strain InsulatorNo1228.51228.54.0FalseNoneNoneFalseNoneFalse4914.00
3957184153364Nonecode432Supplying of 11 kV/433V, 63 kVA, 3 Phase, 50 Cys Distribution Transformer BEE - 5 Star Rated with OilNo191672.25191672.251.0FalseNoneNoneFalseNoneFalse191672.250
3957185153364Nonecode433Supplying of Earthing materials pipe type for grounding (Single Electrode with accessories)No1815.451815.453.0FalseNoneNoneFalseNoneFalse5446.350
3957186153364Nonecode434Supplying of Caution/Danger BoardNo157.5157.51.0FalseNoneNoneFalseNoneFalse157.50
3957187153364Nonecode435supplying of Anti Climbing Device (12 Mtr GI Barbed Wire)No93.4593.452.0FalseNoneNoneFalseNoneFalse186.90
3957188153364Nonecode436Supplying & fixing of GI Wire 8 SWGKg78.7978.795.0FalseNoneNoneFalseNoneFalse393.950
3957189153364Nonecode437Supplying & fixing of Guy wire 7/10 SWGKg81.0981.0910.0FalseNoneNoneFalseNoneFalse810.90
3957190153364Nonecode438Supplying & fixing of 11 kV Lightning Arrester, Metal Oxide 10 kV, 5 kA, Polymeric type with ground disconnectorNo4989.64989.61.0FalseNoneNoneFalseNoneFalse4989.60
3957191153364Nonecode439a) Supplying of LT Protection Kit for 63 kVANo2124.152124.152.0FalseNoneNoneFalseNoneFalse4248.30
3957192153364Nonecode440b) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT i) Al Lead Wire - 95 Sqmmm116.85116.8540.0FalseNoneNoneFalseNoneFalse4674.00
3957193153364Nonecode441b) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT ii) Heavy Duty Long Barrel Copper Lug - 95 SqmmNo135.45135.454.0FalseNoneNoneFalseNoneFalse541.80
3957194153364Nonecode442b) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT iii) PG Clamp - Rabbit to 95 SqmmNo147.0147.04.0FalseNoneNoneFalseNoneFalse588.00
3957195153364Nonecode443b) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT iv) Spacer for DTC WiringNo44.144.18.0FalseNoneNoneFalseNoneFalse352.80
3957196153364Nonecode444b) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT v) Fish Plate with necessary Clamps, bolts & nuts etc complete (Galvanised)No277.2277.22.0FalseNoneNoneFalseNoneFalse554.40
3957197153364Nonecode445c) LT Metering box with CTs and necessary wiring for housing ETV Meter (Please see CDS -39)No5905.25905.21.0FalseNoneNoneFalseNoneFalse5905.20
3957198153364Nonecode446d) LT Electronic Tri-Vector Meter 5 Amps, - 0.5/1.0 Accuracy ClassNo3565.83565.81.0FalseNoneNoneFalseNoneFalse3565.80
3957199153364Nonecode447Supplying of 11 kV, Solid Core Type HG Fuse UnitNo1122.451122.451.0FalseNoneNoneFalseNoneFalse1122.450
3957200153364Nonecode448suppying of 11 kV, 200 Amps, Single Break GOSNo9922.59922.51.0FalseNoneNoneFalseNoneFalse9922.50
3957201153364Nonecode449Fixing of DP Transformer Structure using PSCC Pole - 9 Mtr Long, 300 Kg WL (Including Cost of Poles)No7332.157332.151.0FalseNoneNoneFalseNoneFalse7332.150
3957202153364Nonecode450Fixing of Guy Set Complete with No. 15 Strain InsulatorNo622.65622.654.0FalseNoneNoneFalseNoneFalse2490.60
3957203153364Nonecode451Fixing of 11 kV/433V, 63 kVA, 3 Phase, 50 Cys Distribution Transformer BEE - 5 Star Rated with OilNo1252.651252.651.0FalseNoneNoneFalseNoneFalse1252.650
3957204153364Nonecode452Fixing of Earthing materials pipe type for grounding (Single Electrode with accessories)No996.45996.453.0FalseNoneNoneFalseNoneFalse2989.350
3957205153364Nonecode453Fixing of Caution/Danger BoardNo84.084.01.0FalseNoneNoneFalseNoneFalse84.00
3957206153364Nonecode454Fixing Anti Climbing Device (12 Mtr GI Barbed Wire)No44.144.12.0FalseNoneNoneFalseNoneFalse88.20
3957207153364Nonecode455Fixing of Guy concreting with Boulders, Mud and SandNo262.5262.54.0FalseNoneNoneFalseNoneFalse1050.00
3957208153364Nonecode456a) Fixing of LT Protection Kit for 63 kVANo373.8373.82.0FalseNoneNoneFalseNoneFalse747.60
3957209153364Nonecode457b) LT Wiring (From DTC to LT Line Through Metering Box & LT Protection Kit) SINGLE CIRCUIT i) Al Lead Wire - 95 Sqmm ii) Heavy Duty Long Barrel Copper Lug - 95 Sqmm iii) PG Clamp - Rabbit to 95 Sqmm iv) Spacer for DTC Wiring v) Fish Plate with necessary Clamps, bolts & nuts etc complete (Galvanised)No996.45996.451.0FalseNoneNoneFalseNoneFalse996.450
3957210153364Nonecode458c) fixing of LT Metering box with CTs and necessary wiring for housing ETV Meter (Please see CDS -39)No908.25908.251.0FalseNoneNoneFalseNoneFalse908.250
3957211153364Nonecode459d) fixing of LT Electronic Tri-Vector Meter 5 Amps, - 0.5/1.0 Accuracy ClassNo504.0504.01.0FalseNoneNoneFalseNoneFalse504.00
3957212153364Nonecode460fixing of 11 kV, Solid Core Type HG Fuse UnitNo248.85248.851.0FalseNoneNoneFalseNoneFalse248.850
3957213153364Nonecode461Fixing of 11 kV, 200 Amps, Single Break GOSNo1159.21159.21.0FalseNoneNoneFalseNoneFalse1159.20
3957214153364Nonecode462SUMP TANK EARTH WORK Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work-In all kinds of soils Depth upto 3 m Page No. 8,Sl. No.1.14Cum107.1107.156.0FalseNoneNoneFalseNoneFalse5997.60
3957215153364Nonecode463PCC BED Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately)-Mix 1:4:8( M5) Using 40 mm nominal size graded crushed coarse aggregates Sl.No 2.1.2, Page No.15Cum5947.25947.24.0FalseNoneNoneFalseNoneFalse23788.80
3957216153364Nonecode464EARTH FILLING Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. SL.No 1.9, Page No.7Cum279.3279.33.69FalseNoneNoneFalseNoneFalse1030.6170
3957217153364Nonecode465Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications)- M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 8% ON CONCRETE ITEM) SR -23-24Cum7185.027185.024.85FalseNoneNoneFalseNoneFalse34847.3470
3957218153364Nonecode466RCC Work Providing and laying in position cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/ trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement, dowel bars & formwork to be paid separately)--M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates (RATE INCLUDING CENTERING 20% ON CONCRETE ITEM) Sl No.2.5.2, PageNo.16 Volume-ICum7903.677903.678.09FalseNoneNoneFalseNoneFalse63940.69030
3957219153364Nonecode467Providing and laying in position Cement Concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates RATE INCLUDING CENTERING 50% ON CONCRETE ITEM)Cum10777.7310777.734.85FalseNoneNoneFalseNoneFalse52271.99050
3957220153364Nonecode468PLASTERING Providing 18 mm cement plaster in two coats under layer 12 mm thick cement plaster with cement mortar 1:5 (1 cement : 5 coarse sand) and a top layer 6 mm thick cement plaster with cement mortar 1:3 (1 cement : 3 coarse sand) finished rough with sponge to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. Sl. No. 8.9, Page No.42 Volume-IISqm404.25404.2588.0FalseNoneNoneFalseNoneFalse35574.00
3957221153364Nonecode469Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers including cost of material etc as per specifications and as per directions of the Engineer in-Charge. Sl. No. 8.12, Page No.43 Volume-IISqm67.267.288.0FalseNoneNoneFalseNoneFalse5913.60
3957222153364Nonecode470KSRB 12-6.2: Providing 20mm round M.S. footrest and fixing in manhole with M 10 cement concrete block of 20x20x10cms, using 20mm and down size metal of size including cost of materials, labour charges, curing complete as per specifications. Specification (Page No. 75, Sl. No. 11.45)No266.7266.710.0FalseNoneNoneFalseNoneFalse2667.00
3957223153364Nonecode471STEEL Providing Thermo-Mechanically Treated bars of grade Fe-500D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately) Sl. No. 2.11 a, Page No.18 Volume-IKg82961.5582961.553.84FalseNoneNoneFalseNoneFalse318572.3520
3957224153364Nonecode472Geophysical investigation at site for sinking borewells for Providing drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers's method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, recommended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed for drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test. etc. complete V0L-V SL No 12.4 V-5 PG:140No5552.45552.41.0FalseNoneNoneFalseNoneFalse5552.40
3957225153364Nonecode473Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportatioNof rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: VOL-V SL No 12.2. V-5 PG:139 up to 50mtr 12.2.1m324.45324.4550.0FalseNoneNoneFalseNoneFalse16222.50
3957226153364Nonecode474Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportatioNof rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: VOL-V SL No 12.2. V-5 PG:139 up to 50 to 100 mtr 12.2.2m406.35406.3550.0FalseNoneNoneFalseNoneFalse20317.50
3957227153364Nonecode475Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportatioNof rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: VOL-V SL No 12.2. V-5 PG:139 up to 100 to 150 mtr 12.2.3m432.6432.650.0FalseNoneNoneFalseNoneFalse21630.00
3957228153364Nonecode476Sinking borewell of 150mm dia. clear, using super fast hydraulic rig of capacity 250 PSIG & above 900 CMF and above, in all strata of earth, including over burden upto 20M, fixing of casing pipes, collars and cap with ncessary cutting, threading and welding including transportatioNof rig and supporting vehicles, crew charges, cost of consumables, cost of yield test at the final depth with a minimum working of compressor for one hour etc. complete. The cost excludes the cost of casing pipes, collars and caps etc.) for: VOL-V SL No 12.2. V-5 PG:139 up to 150 to 200mtr 12.2.4m501.9501.950.0FalseNoneNoneFalseNoneFalse25095.00
3957229153364Nonecode477Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for: PVC pipes 140mm dia., 6 kg/sqcm & class 3 VOL-V SL No 10.1.8 pg 113 V-5 140 mm dia casing pipesm613.2613.2180.0FalseNoneNoneFalseNoneFalse110376.00
3957230153364Nonecode478Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary ammendments and instructions of engineer incharge of work. 7.50 HP - 90 LPM @ 165 m = 16 STG Outlet Dia - 2.00" (VOL-V) SL No 13.15.7 V-6 PG: 152No42850.542850.51.0FalseNoneNoneFalseNoneFalse42850.50
3957231153364Nonecode479Supplyinganddrawing3coreflatPVCsheathedsubmersiblepumpcablemanufacturedwithelectrolyticgradecopperwithflexiblecopperwithlowresistanceconductorconfirmingto13:8130 1984andvirgingradePVCinsulationandpowdercoatingextrudedPVCsheathedsuitable for working voltage upto 1100 Volts as per IS-694:1990. 3C x 4 mm2 SL No: 2.6.2 V-6 PG: 7m176.4176.4330.0FalseNoneNoneFalseNoneFalse58212.00
3957232153364Nonecode480Supply and delivery at site GM (copper alloy) gate valves confirming to Class-I as per IS 778 with latest amendments, 1 No. screwed in bonnet inside screw, rising spring spindle integral seat screwed females ends confirming to IS 554/ 1990 body hydraulically tested 1.5HP seat standard tested 1 HP with IS mark. For 50 mm dia GM (Copper alloy) Gate valves VOL-V ) 50 mm Size = 1No SL No: 11.15.6 pg 133 V-5No1772.41772.41.0FalseNoneNoneFalseNoneFalse1772.40
3957233153364Nonecode481Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments (IT NO 28.1 PG NO 162 ) VOL-V 50 mm Size = 1No SL No: 13.25.1 pg 154 V-5No1312.51312.51.0FalseNoneNoneFalseNoneFalse1312.50
3957234153364Nonecode482Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type e NOTE: 1) DOLDirect Online Starter 2) S-D- Star Delta Starter (6 to 15 HP pumps) IT NO 30.2 & PG NO-162 VOL-V SL No: 13.24.3 pg 155 V-5No18375.018375.01.0FalseNoneNoneFalseNoneFalse18375.00
3957235153364Nonecode483Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer incharge of work. ( IT NO 38 & PG NO-163 ,VOL-V) SL No: 13.32 pg 156 V-5No6825.06825.01.0FalseNoneNoneFalseNoneFalse6825.00
3957236153364Nonecode484Supply and delivery of Centrifugal pumpset at site brand new best make and with discharge duty confirming to ISI standards and its latest amendments. 7.5 HP, size 100x100 Head 195M, Discharge 1200 LPM SL No:13.40.6 PG: 157 V-5No32046.032046.01.0FalseNoneNoneFalseNoneFalse32046.00
3957237153364Nonecode485Waste water Treatment by Bio Sewage Treatment Plant (Bio STP) onsite construction [25 KLD and 50 KLD ]: Providing, installation and commissioning of anaerobic Bio Sewage Treatment Plant (Bio STP) for black water with all necessary accessories such as pre- filter, pipes for the onsite constructed ABD tank as per the prescribed specification, according to the capacity, with a baffle wall to control the flow of water and to increase the retention time in the RCC ABD Tank. It includes an internal matrix for enhanced growth of bacteria, rising and falling pipes. For grey water, pre - filter, oil skimmer is provided along with an aerator. Post filter such as sand and carbon filter are also included as per the enclosed detailed technical specification attached as Annexure-2, including cost of material, loading and unloading and as directed by the engineer in charge etc., complete, including annual maintenance of the system for 5 years. Note: 1. Above rates mentioned are for the preparation of estimate purpose only. All items are of ISI standards. 2. After commissioning of plant necessary testing to be done for the 3. Satisfaction of the Engineer in charge. 4. Design drawing of the system suitable for erection 50 KLD is given in figure for reference. Page No. 251 ,Sl. No-22.2.1 B. VOL-5 STP ( 25 KLD)No1359750.01359750.01.0FalseNoneNoneFalseNoneFalse1359750.00
generalCriterionList
createdTsversioncreatedDatemodifiedDatecriterionTypedescriptiontenderEligibilityCriterionDocumentList
17260485410000NoneNoneELIGIBILITYTenders from Joint ventures are not acceptable.None
17260485410000NoneNoneELIGIBILITYBidders shall not be under a declaration of ineligibility for corrupt and fraudulent practices issued by Government of Karnataka None
17260485410000NoneNoneELIGIBILITYBidders shall ensure upload of relevant document certifying his/her status as Scheduled Caste/ Scheduled Tribe/other reserved category as prescribed in the tender document.None
17260485410000NoneNoneELIGIBILITYIt shall be the responsibility of the Bidder to ensure credit of Tender Processing Fee and EMD into the respective receiving bank accounts of e-Procurement on or before the last date and time of bid submission.None
17260485410000NoneNoneELIGIBILITYEMD Payments through e-Payment mode shall be made as one single transaction and payments made in part are liable for rejection.None
17260485520000NoneNoneELIGIBILITYThe tender document is part and parcel of the agreement.None
17260485580000NoneNoneELIGIBILITYThe contractor shall obtain insurance coverage for all the workers deployed for this work.None
17260485610000NoneNoneELIGIBILITYFurther details of the work or any clarifications can be obtained from the office of the Executive Engineer (Central office), KHB, Cauvery Bhavan, K.G. Road, Bangalore Ph: 080-22273511 ext-317,None
17260485650000NoneNoneELIGIBILITYThe intending bidders are requested to note that they should abide by the detailed instructions and conditions contained in the Tender documents and further modifications done if any.None
17260485680000NoneNoneELIGIBILITYCorrigendum/modification/corrections, if any, will be published in the e procurement Web sites only.None
17260485720000NoneNoneELIGIBILITYKHB reserves the right to withdraw or cancel this invitation to BID/Tender without assigning any reason whatsoeverNone
17260485750000NoneNoneELIGIBILITYThe bidder shall study the Tender document Carefully and quote the ratesNone
17260485780000NoneNoneELIGIBILITYAll scanned documents to be uploaded shall be in original and are to be produced to the Executive Engineer to verify the documents within 3 days from the day of opening of Technical bid for verification, if required.None
17260485810000NoneNoneELIGIBILITYDrawings uploaded are only for Tender Purpose only.None
17260485840000NoneNoneELIGIBILITYGST shall be added separately in the estimate.None
17260485870000NoneNoneELIGIBILITYGST shall be paid to the tendered amount separately.None
17260485910000NoneNoneELIGIBILITYThe bidder should maintain register of laborers deployed and wages paid for the workers and shall produce the documents whenever called for by the competent authority. Remittance towards PF shall be commensurate with the labour component of the work involved.None
17260485940000NoneNoneELIGIBILITYThe bidder shall give an undertaking that they would abide by the provisions of employees provident fund and shall remit PF of labourers to the respective PF offices or else KHB have the right to deduct the PF amount from the work bills and remit the same to respective PF offices.None
17260486230000NoneNoneELIGIBILITYThe successful bidder shall give an under taking that they would abide by the provisions of the Employees Provident Fund Act.None
preQualCriterionListNone
technicalCriterionList
createdTsversioncreatedDatemodifiedDatedescriptioncriterionCategoryTextcriterionTypeOthersValuetenderTechnicalCriterionDocumentList
NoneNoneNoneNoneMinimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)NoneNone
NoneNoneNoneNoneSatisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)NoneNone
NoneNoneNoneNoneExecuted in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)NoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneTenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one yearNoneNone
NoneNoneNoneNoneOwning the following key and critical equipment for this work (xxxx, xxxx, xxxx)NoneNone
NoneNoneNoneNoneLiquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)NoneNone
NoneNoneNoneNoneTotal value of civl engineering works executed and payments received in the last five years (year-wise)NoneNone
NoneNoneNoneNoneList of existing commitments and ongoing worksNoneNone
NoneNoneNoneNoneList of works for which tenders already submittedNoneNone
NoneNoneNoneNoneBanker Details for referenceNoneNone
NoneNoneNoneNoneConstruction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneReports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five yearsNoneNone
NoneNoneNoneNoneQualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awardedNoneNone
NoneNoneNoneNoneList of Financial Resources with CertificatesNoneNone
NoneNoneNoneNoneScanned Copy of documentary proof for having executed similar nature of work not less than 50% of tender amount as defined in Government order No.FD 480 EXP-12/2014,Bangalore dated:19.07.2014Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneWork Done Certificate
NoneNoneNoneNoneScanned copy of Pre-qualification letter issued by Karnataka Housing Board.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of Pre-qualification letter issued by Karnataka Housing Board.
NoneNoneNoneNoneAs per Tender Documents KW-4 clause 3.3 key & critical equipments available.Capabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- As per Tender Documents KW-4 clause 3.3 key & critical equipments available.
NoneNoneNoneNoneRequired valid electrical license for executing similar nature of work as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Required valid electrical license for executing similar nature of work as per tender document
NoneNoneNoneNoneThe Tenderer should have executed similar water supply/sanitary engineering works as per tender documentCapabilities of VendorNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- The Tenderer should have executed similar water supply/sanitary engineering works as per tender document
NoneNoneNoneNoneIncome Tax returns & PANFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneITR Filed Copy (Mentioning PAN)
NoneNoneNoneNoneGST Registration CertificateFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneGST Registration
NoneNoneNoneNoneTo qualify for award of this contract , each tenderer in its name should have in the last five years achieved in at least two financial years a minimum financial turnover (In all classes of civil engineering construction works only)Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneAudited CA Certificate of Annual Turnover
NoneNoneNoneNoneScanned copy of latest GST clearance certificate.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Scanned copy of latest GST clearance certificate.
NoneNoneNoneNoneScanned copy of Credit lines/ letter of credit /Bankers certificate for at least 20% of amount put to tender in the current financial year on the name of work put to tender.Financial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneLine of Credit
NoneNoneNoneNoneExecuted in any one Financial year, the minimum quantities of work as mentioned in tender documentFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Executed in any one Financial year, the minimum quantities of work as mentioned in tender document
NoneNoneNoneNoneAssessed Available Bid Capacity as per tender documentFinancial StatusNone
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Assessed Available Bid Capacity as per tender document
NoneNoneNoneNoneCovering letter.OthersCovering letter.
createdTsversioncreatedDatemodifiedDatedocumentName
NoneNoneNoneNoneOthers -- Covering letter.
tenderCriterionDocumentList
documentNameoptionaldocumentTypeText
Annual Turnover CertificateTrueTechnical Bid
Company Registration CertificateTrueTechnical Bid
Reserved Category CertificateFalseTechnical Bid
Small Scale Industries CertificateFalseTechnical Bid
Work done certificateTrueTechnical Bid
key and critical equipment LISTTrueTechnical Bid
Income Tax returns & PAN no.TrueTechnical Bid
Pre-qualification certificate issued by KHBTrueTechnical Bid
GST clearance certificateTrueTechnical Bid
Credit lines/ letter of credit/Bankers certificateTrueTechnical Bid
Assessed available tender capacity calculationTrueTechnical Bid
Electrical licenseTrueTechnical Bid
Work done certificate with quantitiesTrueTechnical Bid
tenderWorkLocationList
tenderAddress
createdTs1726062970000
version0
createdDateNone
modifiedDateNone
blockNumberCAUVERY BHAVAN 3RD FLOOR
streetNone
cityBengaluru
stateKarnataka
pin560009
tenderRecallDTONone