tenderSubEstimateList | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
---|
1726038870000 | 0 | None | None | Buildings | Construction of PWD guest house at Alawandi village (Ground Floor) | 11738281.8 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3954600 | 153238 | None | Vol-1 Pg. No. 8 It. No. 1.12 of 2023-24 | Earth work in surface excavation by mechanical means for lowering & leveling the ground for all works other than foundation in all kinds of soils & upto depth not exceeding 300mm as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenances required to complete the work. In all kinds of soils upto 300 mm depth | Cum | 99.75 | 99.75 | 140.4 | False | None | None | False | None | False | 14004.9 | 0 | 3954601 | 153238 | None | Vol-1 Pg. No. 8 It. No. 1.14.1 of 2023-24 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work. In all kinds of soils Depth upto 3m | Cum | 107.1 | 107.1 | 460.16 | False | None | None | False | None | False | 49283.136 | 0 | 3954602 | 153238 | None | Vol-2 Pg. No. 5 It. No. 4.1 of 2023-24 | Providing and injecting chemical emulsion for Pre-constructional Anti-Termite Treatment, creating continuous chemical barrier under and around the column pits, walls, trenches, basement excavation, top surface of the plinth filling, junction of wall and floor, along the external perimeter of building, expansion joints, over the top surface of consolidated earth on which apron is to be laid, surrounding of pipes and conduits with Chlorpyriphos 20% E.C. / Lindane 20% E.C. @ 3.19 l/m2 including cost of chemical, diluting in water to one percent concentration, labour, usage charges of machinery, complete as per specifications. | Sqm | 123.9 | 123.9 | 508.34 | False | None | None | False | None | False | 62983.326 | 0 | 3954603 | 153238 | None | Vol-1 Pg. No. 15 It. No. 2.1.3 of 2023-24 | Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications. (The cost of steel reinforcement & formwork shall be paid separately) Mix 1:3:6 (M10) Using 40 mm nominal size graded crushed coarse aggregates | Cum | 6288.45 | 6288.45 | 90.32 | False | None | None | False | None | False | 567972.804 | 0 | 3954604 | 153238 | None | Vol-1 Pg. No. 15 It. No. 2.2.3 of 2023-24 | Providing and laying in position Cement concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticizers laid in finished layers, well compacted using needle vibrators, including all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all the other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6652.8 | 6652.8 | 83.64 | False | None | None | False | None | False | 556440.192 | 0 | 3954605 | 153238 | None | Vol-1 Pg. No. 111 It. No. 1.a of 2023-24 | Additional for formwork, Centering & Scaffolding for Sl No 1 a: Foundation upto plinth Isolated. | Cum | 532.22 | 532.22 | 83.64 | False | None | None | False | None | False | 44514.8808 | 0 | 3954606 | 153238 | None | Vol-1 Pg. No. 16 It. No. 2.3.2 of 2023-24 | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6804.0 | 6804.0 | 10.31 | False | None | None | False | None | False | 70149.24 | 0 | 3954607 | 153238 | None | Vol-1 Pg. No. 111 It. No. 9 of 2023-24 | Additional for formwork, Centering & Scaffolding for RCC Columns | Cum | 4762.8 | 4762.8 | 10.31 | False | None | None | False | None | False | 49104.468 | 0 | 3954608 | 153238 | None | Repirt | Providing and laying in Cement Concrete for all Basement & surface level works, return walls, retaining walls, sunken floors etc. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6804.0 | 6804.0 | 12.38 | False | None | None | False | None | False | 84233.52 | 0 | 3954609 | 153238 | None | Vol-1 Pg. No. 112 It. No. 11 of 2023-24 | Additional for formwork, Centering & Scaffolding for Earth retaining structures | Cum | 680.4 | 680.4 | 12.38 | False | None | None | False | None | False | 8423.352 | 0 | 3954610 | 153238 | None | Vol-1 Pg. No. 7 It. No. 1.9 of 2023-24 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 279.3 | 279.3 | 460.16 | False | None | None | False | None | False | 128522.688 | 0 | 3954611 | 153238 | None | Vol-1 Pg. No. 7 It. No. 1.11 of 2023-24 | Filling approved earth (excluding rock) in trenches, plinth, sides of foundations and other similar works etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | Cum | 454.65 | 454.65 | 190.5 | False | None | None | False | None | False | 86610.825 | 0 | 3954612 | 153238 | None | Vol-1 Pg. No. 16 It. No. 2.5.2 of 2023-24 | Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 7185.15 | 7185.15 | 172.25 | False | None | None | False | None | False | 1237642.0875 | 0 | 3954613 | 153238 | None | Vol-1 Pg. No. 111 It. No. 9 of 2023-24 | Additional for formwork, Centering & Scaffolding for RCC Columns | Cum | 5029.6 | 5029.6 | 18.03 | False | None | None | False | None | False | 90683.688 | 0 | 3954614 | 153238 | None | Vol-1 Pg. No. 111 It. No. 2 of 2023-24 | Additional for formwork, Centering & Scaffolding for Plinth beam | Cum | 3592.57 | 3592.57 | 35.58 | False | None | None | False | None | False | 127823.6406 | 0 | 3954615 | 153238 | None | Vol-1 Pg. No. 112 It. No. 14 of 2023-24 | Additional for formwork, Centering & Scaffolding for RCC lintels & Beams | Cum | 4311.09 | 4311.09 | 34.86 | False | None | None | False | None | False | 150284.5974 | 0 | 3954616 | 153238 | None | Vol-1 Pg. No. 112 It. No. 19 of 2023-24 | Additional for formwork, Centering & Scaffolding for Chejjas, Canopy & Other Architectural projections of minor sections | Cum | 3233.32 | 3233.32 | 2.35 | False | None | None | False | None | False | 7598.302 | 0 | 3954617 | 153238 | None | Vol-1 Pg. No. 112 It. No. 15 of 2023-24 | Additional for formwork, Centering & Scaffolding for RCC Roof Slab & Staircase of buildings | Cum | 3592.57 | 3592.57 | 82.43 | False | None | None | False | None | False | 296135.5451 | 0 | 3954618 | 153238 | None | Vol-1 Pg. No. 18 It. No. 2.11.a of 2023-24 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification a. Buildings | Tonne | 93929.85 | 93929.85 | 29.53 | False | None | None | False | None | False | 2773748.4705 | 0 | 3954619 | 153238 | None | Vol-2 Pg. No. 14 It. No. 6.8 of 2023-24 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8367.45 | 8367.45 | 101.79 | False | None | None | False | None | False | 851722.7355 | 0 | 3954620 | 153238 | None | Vol-2 Pg. No. 14 It. No. 6.14 of 2023-24 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Sqm | 1113.0 | 1113.0 | 31.07 | False | None | None | False | None | False | 34580.91 | 0 | 3954621 | 153238 | None | Vol-1 Pg. No. 16 It. No. 2.4.1 of 2023-24 | Providing and laying in position Cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6724.2 | 6724.2 | 13.27 | False | None | None | False | None | False | 89230.134 | 0 | 3954622 | 153238 | None | Vol-2 Pg. No. 43 It. No. 8.16.2 of 2023-24 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment plaster mesh 150mm wide | m | 39.9 | 39.9 | 789.2 | False | None | None | False | None | False | 31489.08 | 0 | 3954623 | 153238 | None | Vol-2 Pg. No. 41 It. No. 8.1.2 of 2023-24 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth
rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of
Engineer-in-charge | Sqm | 253.05 | 253.05 | 940.15 | False | None | None | False | None | False | 237904.9575 | 0 | 3954624 | 153238 | None | Vol-2 Pg. No. 42 It. No. 8.5.2 of 2023-24 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 366.45 | 366.45 | 532.03 | False | None | None | False | None | False | 194962.3935 | 0 | 3954625 | 153238 | None | Vol-2 Pg. No. 44 It. No. 8.16.a of 2023-24 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixing chicken mesh for drop chajja, facia, backing to cup boards including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specifications. Specification No. KBS padadi works for arches as per design & drawing | Sqm | 1299.9 | 1299.9 | 5.79 | False | None | None | False | None | False | 7526.421 | 0 | 3954626 | 153238 | None | Vol-2 Pg. No. 60 It. No. 9.12.2 of 2023-24 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.. Size of Tile 600x600 mm | Sqm | 1202.25 | 1202.25 | 286.89 | False | None | None | False | None | False | 344913.5025 | 0 | 3954627 | 153238 | None | Vol-2 Pg. No. 60 It. No. 9.11 of 2023-24 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 933.45 | 933.45 | 31.62 | False | None | None | False | None | False | 29515.689 | 0 | 3954628 | 153238 | None | Vol-2 Pg. No. 65 It. No. 9.39 of 2023-24 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1521.45 | 1521.45 | 129.86 | False | None | None | False | None | False | 197575.497 | 0 | 3954629 | 153238 | None | Vol-2 Pg. No. 64 It. No. 9.36 of 2023-24 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. | Sqm | 1732.5 | 1732.5 | 30.7 | False | None | None | False | None | False | 53187.75 | 0 | 3954630 | 153238 | None | Vol-2 Pg. No. 63 It. No. 9.24 of 2023-24 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. | Sqm | 2994.6 | 2994.6 | 273.15 | False | None | None | False | None | False | 817974.99 | 0 | 3954631 | 153238 | None | Vol-2 Pg. No. 69 It. No. 10.2 of 2023-24 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge | m | 344.4 | 344.4 | 294.96 | False | None | None | False | None | False | 101584.224 | 0 | 3954632 | 153238 | None | Vol-2 Pg. No. 99 It. No. 12.12 of 2023-24 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 130412.1 | 130412.1 | 1.33 | False | None | None | False | None | False | 173448.093 | 0 | 3954633 | 153238 | None | Vol-2 Pg. No. 104 It. No. 12.51 of 2023-24 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1066.8 | 1066.8 | 12.0 | False | None | None | False | None | False | 12801.6 | 0 | 3954634 | 153238 | None | Vol-2 Pg. No. 105 It. No. 12.57.5 of 2023-24 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick one side teak and one side commercial | Sqm | 4091.85 | 4091.85 | 31.68 | False | None | None | False | None | False | 129629.808 | 0 | 3954635 | 153238 | None | Vol-2 Pg. No. 111 It. No. 12.93.1 of 2023-24 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62x100mm | m | 737.1 | 737.1 | 34.2 | False | None | None | False | None | False | 25208.82 | 0 | 3954636 | 153238 | None | Vol-2 Pg. No. 111 It. No. 12.94.1 of 2023-24 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges. (Cost of Fixtures to be paid separately) 30mm thickness | Sqm | 3659.25 | 3659.25 | 9.45 | False | None | None | False | None | False | 34579.9125 | 0 | 3954637 | 153238 | None | Vol-2 Pg. No. 110 It. No. 12.90 of 2023-24 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size -2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 7070.7 | 7070.7 | 44.04 | False | None | None | False | None | False | 311393.628 | 0 | 3954638 | 153238 | None | Vol-2 Pg. No. 109 It. No. 12.85 of 2023-24 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size- 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 6004.95 | 6004.95 | 3.66 | False | None | None | False | None | False | 21978.117 | 0 | 3954639 | 153238 | None | Vol-2 Pg. No. 86 It. No. 11.34B of 2023-24 | Providing and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. | Kg | 192.15 | 192.15 | 1001.7 | False | None | None | False | None | False | 192476.655 | 0 | 3954640 | 153238 | None | Vol-2 Pg. No. 85 It. No. 11.28 of 2023-24 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 593.25 | 593.25 | 407.12 | False | None | None | False | None | False | 241523.94 | 0 | 3954641 | 153238 | None | Vol-2 Pg. No. 50 It. No. 8.51 of 2023-24 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 105.0 | 105.0 | 1429.8 | False | None | None | False | None | False | 150129.0 | 0 | 3954642 | 153238 | None | Vol-2 Pg. No. 46 It. No. 8.33.1 of 2023-24 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, afterthoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life). | Sqm | 165.9 | 165.9 | 1429.8 | False | None | None | False | None | False | 237203.82 | 0 | 3954643 | 153238 | None | Vol-2 Pg. No. 46 It. No. 8.32 of 2023-24 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 163.8 | 163.8 | 532.02 | False | None | None | False | None | False | 87144.876 | 0 | 3954644 | 153238 | None | Vol-2 Pg. No. 46 It. No. 8.33.2 of 2023-24 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 144.9 | 144.9 | 43.09 | False | None | None | False | None | False | 6243.741 | 0 | 3954645 | 153238 | None | Vol-2 Pg. No. 47 It. No. 8.33.3 of 2023-24 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 145.95 | 145.95 | 47.7 | False | None | None | False | None | False | 6961.815 | 0 | 3954646 | 153238 | None | Vol-2 Pg. No. 107 It. No. 12.74.1 of 2023-24 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm | Nos | 107.1 | 107.1 | 68.0 | False | None | None | False | None | False | 7282.8 | 0 | 3954647 | 153238 | None | Vol-2 Pg. No. 107 It. No. 12.74.3 of 2023-24 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 75x47x1.80mm | Nos | 75.6 | 75.6 | 18.0 | False | None | None | False | None | False | 1360.8 | 0 | 3954648 | 153238 | None | Vol-2 Pg. No. 108 It. No. 12.60 of 2023-24 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete | Nos | 1104.6 | 1104.6 | 18.0 | False | None | None | False | None | False | 19882.8 | 0 | 3954649 | 153238 | None | Vol-2 Pg. No. 218 It. No. 22.15.7 of 2023-24 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in chargee SS Tower Bolts 250x10mm | Nos | 210.0 | 210.0 | 17.0 | False | None | None | False | None | False | 3570.0 | 0 | 3954650 | 153238 | None | Vol-2 Pg. No. 218 It. No. 22.15.5 of 2023-24 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in chargee SS Tower Bolts 150x10mm | Nos | 126.0 | 126.0 | 6.0 | False | None | None | False | None | False | 756.0 | 0 | 3954651 | 153238 | None | Vol-2 Pg. No. 218 It. No. 22.15.4 of 2023-24 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in chargee SS Aldrop 16mm dia, 300mm | Nos | 393.75 | 393.75 | 24.0 | False | None | None | False | None | False | 9450.0 | 0 | 3954652 | 153238 | None | Vol-2 Pg. No. 218 It. No. 22.15.3 of 2023-24 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in chargee SS Aldrop 16mm dia, 200mm | Nos | 315.0 | 315.0 | 12.0 | False | None | None | False | None | False | 3780.0 | 0 | 3954653 | 153238 | None | Vol-2 Pg. No. 218 It. No. 22.9.a of 2023-24 | Providing and fixing stainless steel 304 grade fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-incharge. 200mm length | Nos | 1575.0 | 1575.0 | 23.0 | False | None | None | False | None | False | 36225.0 | 0 | 3954654 | 153238 | None | Vol-2 Pg. No. 105 It. No. 12.59 of 2023-24 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete. | Nos | 1169.7 | 1169.7 | 17.0 | False | None | None | False | None | False | 19884.9 | 0 | 3954655 | 153238 | None | Vol-2 Pg. No. 72 It. No. 10.20 of 2023-24 | Providing and fixing of clay tiles for cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface and the surface is painted with red apex paint and black apex paint into the groves. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification. | Sqm | 1997.1 | 1997.1 | 8.96 | False | None | None | False | None | False | 17894.016 | 0 | 3954656 | 153238 | None | Vol-2 Pg. No. 45 It. No. 8.29 of 2023-24 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 297.15 | 297.15 | 18.48 | False | None | None | False | None | False | 5491.332 | 0 | 3954657 | 153238 | None | Vol-2 Pg. No. 54 It. No. 8.80 of 2023-24 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove
complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. | m | 69.3 | 69.3 | 325.0 | False | None | None | False | None | False | 22522.5 | 0 | 3954658 | 153238 | None | Vol-2 Pg. No. 25 It. No. 7.32.1 of 2023-24 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 g/m2 (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound,
jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost
of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the
cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095-
(Part I) : 2011 (Board with BIS Certification marks only) | Sqm | 1032.15 | 1032.15 | 460.85 | False | None | None | False | None | False | 475666.3275 | 0 | 3954659 | 153238 | None | Vol-2 Pg. No. 18 It. No. 6.38 of 2023-24 | Fabrication and manufacturing of M35 Grade solid precast concrete element with provisions of shear keys, connecting loops, dowel tubes and proper lifting accessories for walls, beams, slabs, stairs, column etc, of various thickness, shape and size of different concrete grades manufactured in controlled factory environment with approved methodology including moulds (Pallet system, Tilts form, table moulds, battery moulds, vertical
moulds, beam moulds, column moulds, staircase moulds, Facade mould, etc.), mixing, transporting and placing of concrete, vibrating, curing, finishing, making necessary cutout/holes of required sizes for services, yard handling & stacking all complete as per IS : 11447:1985 and as per approved shop drawings and design mix as per the direction of Engineerin- Charge (Cost of reinforcement, Mechanical, Electrical and Plumbing
inserts will be paid separately). | Cum | 17879.4 | 17879.4 | 4.78 | False | None | None | False | None | False | 85463.532 | 0 |
| 1726038871000 | 0 | None | None | Buildings | Construction of PWD guest house at Alwandi village (First Floor) | 8673342.25 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3954660 | 153239 | None | Vol-1 Pg. No. 16 It. No. 2.5.2 of 2023-24 | Providing and laying in position Cement concrete for all Super structures of building , Road works, Water works, Irrigation works & super structure works of bridges upto 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers laid in layers, well compacted using needle vibrators. The cost includes all lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. M25 Design Mix Using 20 mm nominal size graded crushed coarse aggregates. | Cum | 7257.0 | 7257.0 | 142.26 | False | None | None | False | None | False | 1032380.82 | 0 | 3954661 | 153239 | None | Vol-1 Pg. No. 111 It. No. 9 of 2023-24 | Additional for formwork, Centering & Scaffolding for RCC Columns | Cum | 5079.9 | 5079.9 | 19.21 | False | None | None | False | None | False | 97584.879 | 0 | 3954662 | 153239 | None | Vol-1 Pg. No. 112 It. No. 14 of 2023-24 | Additional for formwork, Centering & Scaffolding for RCC lintels & Beams | Cum | 4354.2 | 4354.2 | 37.56 | False | None | None | False | None | False | 163543.752 | 0 | 3954663 | 153239 | None | Vol-1 Pg. No. 112 It. No. 19 of 2023-24 | Additional for formwork, Centering & Scaffolding for Chejjas, Canopy & Other Architectural projections of minor sections | Cum | 3265.65 | 3265.65 | 1.76 | False | None | None | False | None | False | 5747.544 | 0 | 3954664 | 153239 | None | Vol-1 Pg. No. 112 It. No. 15 of 2023-24 | Additional for formwork, Centering & Scaffolding for RCC Roof Slab & Staircase of buildings | Cum | 3628.5 | 3628.5 | 83.85 | False | None | None | False | None | False | 304249.725 | 0 | 3954665 | 153239 | None | Vol-1 Pg. No. 18 It. No. 2.11.a of 2023-24 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification a. Buildings | Tonne | 94869.15 | 94869.15 | 16.73 | False | None | None | False | None | False | 1587160.8795 | 0 | 3954666 | 153239 | None | Vol-2 Pg. No. 14 It. No. 6.8 of 2023-24 | Providing Brick work with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work. | Cum | 8451.12 | 8451.12 | 123.21 | False | None | None | False | None | False | 1041262.4952 | 0 | 3954667 | 153239 | None | Vol-2 Pg. No. 14 It. No. 6.14 of 2023-24 | Providing Half brick masonry with common burnt clay Non Modular bricks of class designation 3.5 in superstructure above plinth level up to floor 1 level cement mortar 1:3 (1 cement :3 coarse sand) including cost of all materials, labour, scaffolding and usage charges of machinery & other incidental charges complete as per the direction of engineer incharge of work | Sqm | 1124.13 | 1124.13 | 36.99 | False | None | None | False | None | False | 41581.5687 | 0 | 3954668 | 153239 | None | Vol-1 Pg. No. 16 It. No. 2.4.1 of 2023-24 | Providing and laying in position Cement concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necesary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. (Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 6791.44 | 6791.44 | 4.33 | False | None | None | False | None | False | 29406.9352 | 0 | 3954669 | 153239 | None | Vol-2 Pg. No. 43 It. No. 8.16.2 of 2023-24 | Providing and fixing suitable plaster mesh 100mm wide manufactured out of hot dipped galvanised iron of nominal thickness 0.35mm with a zinc coating of 120g/m2 width, along route of walls chipped for services, junction between RCC and brick walls including cost of materials, labour for fixing complete as per specifications. ( length of mesh only be measured for payment plaster mesh 150mm wide | m | 40.3 | 40.3 | 789.2 | False | None | None | False | None | False | 31804.76 | 0 | 3954670 | 153239 | None | Vol-2 Pg. No. 41 It. No. 8.1.2 of 2023-24 | Providing 12 mm cement plaster with cement mortar 1:6 (1 cement: 6 fine sand) including rounding off corners wherever required smooth
rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of
Engineer-in-charge. | Sqm | 255.58 | 255.58 | 1118.74 | False | None | None | False | None | False | 285927.5692 | 0 | 3954671 | 153239 | None | Vol-2 Pg. No. 42 It. No. 8.5.2 of 2023-24 | Providing 15 mm cement plaster on rough side of single or half brick wall finished with a floating coat of neat cement of mix: 1:4 (1 cement: 4 fine sand) to brick masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 370.11 | 370.11 | 467.3 | False | None | None | False | None | False | 172952.403 | 0 | 3954672 | 153239 | None | Vol-2 Pg. No. 44 It. No. 8.16.a of 2023-24 | Providing lath plaster with cement mortar 1:3, 5cms thick with 6mm dia mild steel bars at 20 cms. c to c both horizontally and vertically fixing chicken mesh for drop chajja, facia, backing to cup boards including cost of all materials, labour, providing and removing form work HOM of machineries, curing, complete as per specifications. Specification No. KBS padadi works for arches as per design & drawing | Sqm | 1312.9 | 1312.9 | 2.24 | False | None | None | False | None | False | 2940.896 | 0 | 3954673 | 153239 | None | Vol-2 Pg. No. 60 It. No. 9.12.2 of 2023-24 | Providing and laying vitrified floor tiles with thickness 9-10 mm in different sizes with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.. Size of Tile 600x600 mm | Sqm | 1214.27 | 1214.27 | 297.04 | False | None | None | False | None | False | 360686.7608 | 0 | 3954674 | 153239 | None | Vol-2 Pg. No. 60 It. No. 9.11 of 2023-24 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including pointing the joints with white cement and matching pigments etc., complete. | Sqm | 942.78 | 942.78 | 31.32 | False | None | None | False | None | False | 29527.8696 | 0 | 3954675 | 153239 | None | Vol-2 Pg. No. 65 It. No. 9.39 of 2023-24 | Providing skirting, dadooing, rises of steps with colour glazed tiles 6mm thick on 10mm thick cement plaster 1:3 and jointed with white cement slurry over existing rough plaster surface using glazed tiles of approved make and size including cost of materials, labour, complete as per specifications. | Sqm | 1536.66 | 1536.66 | 102.32 | False | None | None | False | None | False | 157231.0512 | 0 | 3954676 | 153239 | None | Vol-2 Pg. No. 64 It. No. 9.36 of 2023-24 | Providing flooring with 25mm thick polished Cuddapah slabs using cement mortar 1:6, 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab , including cost of materials, labour, curing, polishing complete as per specifications. | Sqm | 1749.83 | 1749.83 | 23.72 | False | None | None | False | None | False | 41505.9676 | 0 | 3954677 | 153239 | None | Vol-2 Pg. No. 63 It. No. 9.24 of 2023-24 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. | Sqm | 3024.55 | 3024.55 | 178.03 | False | None | None | False | None | False | 538460.6365 | 0 | 3954678 | 153239 | None | Vol-2 Pg. No. 69 It. No. 10.2 of 2023-24 | Providing edge moulding to 18mm thick Granite stone counters, vanities etc including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-charge | m | 347.84 | 347.84 | 156.18 | False | None | None | False | None | False | 54325.6512 | 0 | 3954679 | 153239 | None | Vol-2 Pg. No. 99 It. No. 12.12 of 2023-24 | Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves (excluding cost of cement concrete and side clamps ), but including cost of materials, labour, usage charges complete as per specifications. | Cum | 131716.22 | 131716.22 | 1.25 | False | None | None | False | None | False | 164645.275 | 0 | 3954680 | 153239 | None | Vol-2 Pg. No. 104 It. No. 12.51 of 2023-24 | Fixing of door frame in an existing opening including embedding frame in floor and walls after cutting masonry for holdfasts for embedding holdfast in cement concrete 1:3:6 of 20mm and down size granite metal painting two coats of coal tar to sides of frame, making good the damages to walls and floor as required and disposal of the debris with lead upto 50 m. including cost of materials, labour charges, complete as per specifications. | Nos | 1077.47 | 1077.47 | 12.0 | False | None | None | False | None | False | 12929.64 | 0 | 3954681 | 153239 | None | Vol-2 Pg. No. 105 It. No. 12.57.5 of 2023-24 | Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame alround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per spcification. -do- 35 mm thick one side teak and one side commercial | Sqm | 4132.77 | 4132.77 | 32.88 | False | None | None | False | None | False | 135885.4776 | 0 | 3954682 | 153239 | None | Vol-2 Pg. No. 111 It. No. 12.93.1 of 2023-24 | Providing and fixing factory made single extruded WPC (Wood Polymer Composite) solid door/window Clerestory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for100 g) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 850 kg/m3, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2 , modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-InCharge. (Fixtures shall be paid for separately) Size 62x100mm | m | 744.47 | 744.47 | 39.9 | False | None | None | False | None | False | 29704.353 | 0 | 3954683 | 153239 | None | Vol-2 Pg. No. 111 It. No. 12.94.1 of 2023-24 | Providing and fixing factory made Green certified, Anti Termite, UV resistant, high water absorbant single extruded WPC (Wood PolymerComposite) solid plain flush door shutter of required size comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength of 50 N/mm2 , modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws The cost includes cost of materials, transportation, labour and fixing charges. (Cost of Fixtures to be paid separately) 30mm thickness | Sqm | 3695.84 | 3695.84 | 11.02 | False | None | None | False | None | False | 40728.1568 | 0 | 3954684 | 153239 | None | Vol-2 Pg. No. 110 It. No. 12.90 of 2023-24 | Providing & fixing of 3-track x 2-panel sliding windows made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free, gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the window frame. The outer frame having an overall size of 108mm width x 45mmheight with reinforcement of 1mm thickness and Sash with overall size of 39mm x 75mm with GI reinforcement of 2mm and mesh sash of size 37mm x 58mm. Coextruded Glazing bead for fixing of glass shall be of size 20mm x 24 mm. Windows shall be provided with 6mm plain float glass, standard hardware& Multi point locking system with touch lock. Wall thickness of frame & sash shall be of 2mm-2.5mm. Maximum possible size -2419mm x 2200mm. (The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 7141.41 | 7141.41 | 45.99 | False | None | None | False | None | False | 328433.4459 | 0 | 3954685 | 153239 | None | Vol-2 Pg. No. 109 It. No. 12.85 of 2023-24 | Providing & fixing of louvered ventilator made out of multi chambered UPVC(Matching to RAL-9016) sections and with minimum TiO2(Titanium Dioxide) at 6PHR with TPE(Thermo Plastic Elastomer) and lead free with gaskets -grey colour having isolated drainage and reinforced with Galvanized Iron profile through-out the ventilator frame. The frame having overall size of 39mm x 39mm with GI reinforcement of 1mm thickness. Louver clip in Aluminium (powder coated in white) will be used on the frame along with plastic parts for fixing the 4 mm pin head glass. Wall thickness of frame shall be 2mm.Maximum possible size - 1000mm x 1000mm.(The cost is inclusive of all fixtures and separate charges for minor T&P's shall not be made) | Sqm | 6065.0 | 6065.0 | 2.25 | False | None | None | False | None | False | 13646.25 | 0 | 3954686 | 153239 | None | Vol-2 Pg. No. 86 It. No. 11.34B of 2023-24 | Providing and fixing M.S. grills of required pattern in frames of win- dows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. Fixed to openings / wooden frames with rawl plugs screws etc. | Kg | 194.07 | 194.07 | 1013.04 | False | None | None | False | None | False | 196600.6728 | 0 | 3954687 | 153239 | None | Vol-2 Pg. No. 85 It. No. 11.28 of 2023-24 | Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in- charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 599.18 | 599.18 | 427.28 | False | None | None | False | None | False | 256017.6304 | 0 | 3954688 | 153239 | None | Vol-2 Pg. No. 50 It. No. 8.51 of 2023-24 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete as per specifications and as per directions of Engineer in charge. | Sqm | 106.05 | 106.05 | 1640.66 | False | None | None | False | None | False | 173991.993 | 0 | 3954689 | 153239 | None | Vol-2 Pg. No. 46 It. No. 8.33.1 of 2023-24 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications: Two coats applied on walls @ 1.25 L/10 m² over and including one coat of Special primer applied @ 0.75 L/10 m² with paint of approved quality to give an even shade, afterthoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. (The gloss should be 50% @ 60 degree angle with 10 years life). | Sqm | 167.56 | 167.56 | 1640.66 | False | None | None | False | None | False | 274908.9896 | 0 | 3954690 | 153239 | None | Vol-2 Pg. No. 46 It. No. 8.32 of 2023-24 | Finishing walls with 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives, New work (Two coats applied @ 1.43 litre/ 10 m². Over and including priming coat of exterior primer applied @ 0.90 litre/10 m² with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 165.44 | 165.44 | 467.29 | False | None | None | False | None | False | 77308.4576 | 0 | 3954691 | 153239 | None | Vol-2 Pg. No. 46 It. No. 8.33.2 of 2023-24 | Painting wood work with Deluxe Multi Surface Paint of required shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @0.75 ltr/10 m² of approved brand and manufacture to give an even shade including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, sand papering and knotting , cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 146.35 | 146.35 | 38.07 | False | None | None | False | None | False | 5571.5445 | 0 | 3954692 | 153239 | None | Vol-2 Pg. No. 47 It. No. 8.33.3 of 2023-24 | Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two coat applied @ 0.90 ltr/10 m² over an under coat of primer applied @ 0.80 ltr/10 m² of approved brand and manufacture including preparing the surface after thorougly cleaning oil, grease, dirt and foreign matter, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 147.41 | 147.41 | 48.24 | False | None | None | False | None | False | 7111.0584 | 0 | 3954693 | 153239 | None | Vol-2 Pg. No. 107 It. No. 12.74.1 of 2023-24 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 125x64x1.90mm. | Nos | 108.17 | 108.17 | 72.0 | False | None | None | False | None | False | 7788.24 | 0 | 3954694 | 153239 | None | Vol-2 Pg. No. 107 It. No. 12.74.3 of 2023-24 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : 75x47x1.80mm | Nos | 76.36 | 76.36 | 21.0 | False | None | None | False | None | False | 1603.56 | 0 | 3954695 | 153239 | None | Vol-2 Pg. No. 108 It. No. 12.60 of 2023-24 | Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete | Nos | 1115.65 | 1115.65 | 11.0 | False | None | None | False | None | False | 12272.15 | 0 | 3954696 | 153239 | None | Vol-2 Pg. No. 218 It. No. 22.15.7 of 2023-24 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in chargee SS Tower Bolts 250x10mm | Nos | 212.1 | 212.1 | 18.0 | False | None | None | False | None | False | 3817.8 | 0 | 3954697 | 153239 | None | Vol-2 Pg. No. 218 It. No. 22.15.5 of 2023-24 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in chargee SS Tower Bolts 150x10mm | Nos | 127.26 | 127.26 | 7.0 | False | None | None | False | None | False | 890.82 | 0 | 3954698 | 153239 | None | Vol-2 Pg. No. 218 It. No. 22.15.4 of 2023-24 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in chargee SS Aldrop 16mm dia, 300mm | Nos | 397.69 | 397.69 | 22.0 | False | None | None | False | None | False | 8749.18 | 0 | 3954699 | 153239 | None | Vol-2 Pg. No. 218 It. No. 22.15.3 of 2023-24 | Providing and fixing Stainless Steel Fixtures conforming to 304 graded steel as per direction of engineer in chargee SS Aldrop 16mm dia, 200mm | Nos | 318.15 | 318.15 | 14.0 | False | None | None | False | None | False | 4454.1 | 0 | 3954700 | 153239 | None | Vol-2 Pg. No. 218 It. No. 22.9.a of 2023-24 | Providing and fixing stainless steel 304 grade fancy handle of approved make fixed with SS screws etc. complete as per direction of Engineer-incharge. 200mm length | Nos | 1590.75 | 1590.75 | 18.0 | False | None | None | False | None | False | 28633.5 | 0 | 3954701 | 153239 | None | Vol-2 Pg. No. 105 It. No. 12.59 of 2023-24 | Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete | Nos | 1181.4 | 1181.4 | 18.0 | False | None | None | False | None | False | 21265.2 | 0 | 3954702 | 153239 | None | Vol-2 Pg. No. 23 It. No. 7.18 of 2023-24 | Providing and laying cinder concrete in cement 1:15 ( 1 cement : 15 cinder of 12.5mm nominal gauge) on terraced roof or sunken slabs, laid to slope compacting, including cost of materials, labour, curing complete as per specifications. | Cum | 2139.03 | 2139.03 | 9.38 | False | None | None | False | None | False | 20064.1014 | 0 | 3954703 | 153239 | None | Vol-2 Pg. No. 72 It. No. 10.20 of 2023-24 | Providing and fixing of clay tiles for cladding tiles of size 230x75x10mm thick on 12mm thick cement mortar 1:3 (1 cement : 3 coarse sand) & jointed with Adhesive/cement slurry over rough plaster surface excluding cost of rough plastered surface and the surface is painted with red apex paint and black apex paint into the groves. The work includes cost of all materials, labour charges for all items of work, usage charges for equipment, etc., complete as per specification. | Sqm | 2017.07 | 2017.07 | 8.96 | False | None | None | False | None | False | 18072.9472 | 0 | 3954704 | 153239 | None | Vol-2 Pg. No. 45 It. No. 8.29 of 2023-24 | Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 L/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an even shade after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per
directions of Engineer-in-charge. | Sqm | 300.12 | 300.12 | 18.48 | False | None | None | False | None | False | 5546.2176 | 0 | 3954705 | 153239 | None | Vol-2 Pg. No. 84 It. No. 11.26.3 of 2023-24 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. G.I. pipes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kg | 194.07 | 194.07 | 333.25 | False | None | None | False | None | False | 64673.8275 | 0 | 3954706 | 153239 | None | Vol-2 Pg. No. 54 It. No. 8.80 of 2023-24 | Forming groove of uniform size in the top layer of plaster as per approved pattern including repair to the edges of panels and finishing the groove
complete as per specifications and direction of the Engineer-in-charge: 20 mm to 25 mm wide to required depth. | m | 69.99 | 69.99 | 325.0 | False | None | None | False | None | False | 22746.75 | 0 | 3954707 | 153239 | None | Vol-2 Pg. No. 25 It. No. 7.32.1 of 2023-24 | Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 g/m2 (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound, jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer's specification and also including the cost
of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the
cost of painting with : 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095-
(Part I) : 2011 (Board with BIS Certification marks only) | Sqm | 1042.47 | 1042.47 | 479.38 | False | None | None | False | None | False | 499739.2686 | 0 | 3954708 | 153239 | None | Vol-2 Pg. No. 82 It. No. 11.16.1 of 2023-24 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions
of the Engineer-in-Charge. | Kg | 144.23 | 144.23 | 1108.8 | False | None | None | False | None | False | 159922.224 | 0 | 3954709 | 153239 | None | Vol-2 Pg. No. 26 It. No. 7.35 of 2023-24 | Providing & fixing on roof pressed clay tile (Mangalore tile) of 20 mm nominal thickness and of approved size and as per approved pattern on
steel frame work complete. | Sqm | 311.79 | 311.79 | 50.4 | False | None | None | False | None | False | 15714.216 | 0 | 3954710 | 153239 | None | Vol-2 Pg. No. 18 It. No. 6.38 of 2023-24 | Fabrication and manufacturing of M35 Grade solid precast concrete element with provisions of shear keys, connecting loops, dowel tubes and proper lifting accessories for walls, beams, slabs, stairs, column etc, of various thickness, shape and size of different concrete grades manufactured in controlled factory environment with approved methodology including moulds (Pallet system, Tilts form, table moulds, battery moulds, vertical
moulds, beam moulds, column moulds, staircase moulds, Facade mould, etc.), mixing, transporting and placing of concrete, vibrating, curing, finishing, making necessary cutout/holes of required sizes for services, yard handling & stacking all complete as per IS : 11447:1985 and as per approved shop drawings and design mix as per the direction of Engineerin- Charge (Cost of reinforcement, Mechanical, Electrical and Plumbing
inserts will be paid separately). | Cum | 18058.19 | 18058.19 | 4.52 | False | None | None | False | None | False | 81623.0188 | 0 |
| 1726038871000 | 0 | None | None | Buildings | Water supply works | 783795.39 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3954711 | 153240 | None | Vol-2 Pg. No. 122 It. No. 13.33.3 of 2023-24 | Providing and fixing Chorinated poly venyl cloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings,this includes jointing of pipes and fitting with one step CPVC solvent cement,trenching,refilling & testing of joints complete as per direction of Engineer incharge (external work) 25mm nominal OD pipes | m | 310.8 | 310.8 | 250.0 | False | None | None | False | None | False | 77700.0 | 0 | 3954712 | 153240 | None | Vol-2 Pg. No. 123 It. No. 13.33.5 of 2023-24 | Providing and fixing Chorinated poly venyl cloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings,this includes jointing of pipes and fitting with one step CPVC solvent cement,trenching,refilling & testing of joints complete as per direction of Engineer incharge (external work) 40mm nominal OD pipes | m | 500.85 | 500.85 | 60.0 | False | None | None | False | None | False | 30051.0 | 0 | 3954713 | 153240 | None | Vol-2 Pg. No. 123 It. No. 13.33.6 of 2023-24 | Providing and fixing Chorinated poly venyl cloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings,this includes jointing of pipes and fitting with one step CPVC solvent cement,trenching,refilling & testing of joints complete as per direction of Engineer incharge (external work) 50mm nominal OD pipes | m | 757.05 | 757.05 | 120.0 | False | None | None | False | None | False | 90846.0 | 0 | 3954714 | 153240 | None | Vol-2 Pg. No. 122 It. No. 13.32.2 of 2023-24 | Providing and fixing Chorinated poly venyl cloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer incharge. (Concealed work including cutting chases and good the walls etc.,.) 20mm nominal OD pipes. | m | 397.95 | 397.95 | 200.0 | False | None | None | False | None | False | 79590.0 | 0 | 3954715 | 153240 | None | Vol-2 Pg. No. 122 It. No. 13.32.3 of 2023-24 | Providing and fixing Chorinated poly venyl cloride (CPVC) pipes, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamp at 1.00 mtr spacing. This includes jointing of pipes and fitting with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer incharge. (Concealed work including cutting chases and good the walls etc.,.) 25mm nominal OD pipes | m | 500.85 | 500.85 | 100.0 | False | None | None | False | None | False | 50085.0 | 0 | 3954716 | 153240 | None | Vol-2 Pg. No. 117 It. No. 13.4.1 of 2023-24 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 25 mm nominal bore | Each | 576.45 | 576.45 | 10.0 | False | None | None | False | None | False | 5764.5 | 0 | 3954717 | 153240 | None | Vol-2 Pg. No. 117 It. No. 13.4.3 of 2023-24 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 40 mm nominal bore | Each | 737.1 | 737.1 | 2.0 | False | None | None | False | None | False | 1474.2 | 0 | 3954718 | 153240 | None | Vol-2 Pg. No. 117 It. No. 13.4.4 of 2023-24 | Providing and fixing Brass full way valve gate with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore. | Each | 897.75 | 897.75 | 2.0 | False | None | None | False | None | False | 1795.5 | 0 | 3954719 | 153240 | None | Vol-2 Pg. No. 119 It. No. 13.14 of 2023-24 | Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 g | Nos | 888.3 | 888.3 | 16.0 | False | None | None | False | None | False | 14212.8 | 0 | 3954720 | 153240 | None | Vol-2 Pg. No. 140 It. No. 14.60.a of 2023-24 | Providing and fixing Single lever wall mixer with L shaped Tubular bend set for overhead shower made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete -Economy Class | Nos | 4184.25 | 4184.25 | 3.0 | False | None | None | False | None | False | 12552.75 | 0 | 3954721 | 153240 | None | Vol-2 Pg. No. 140 It. No. 14.60.b of 2023-24 | Providing and fixing Single lever wall mixer with L shaped Tubular bend set for overhead shower made of Stainless steel with all concealed fitting arrangements & all necessary accesories complete -Premium Class | Nos | 8869.35 | 8869.35 | 2.0 | False | None | None | False | None | False | 17738.7 | 0 | 3954722 | 153240 | None | Vol-2 Pg. No. 123 It. No. 13.37 of 2023-24 | Cutting holes up to 15x15cm in R.C.C floors and roofs for passing drain pipe etc., and repairing the hole after insertion of drain pipe etc., with cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) including finishing complete so as to make it leak proof | Nos | 328.65 | 328.65 | 120.0 | False | None | None | False | None | False | 39438.0 | 0 | 3954723 | 153240 | None | Vol-2 Pg. No. 123 It. No. 13.36 of 2023-24 | Cutting holes up to 30x30cm in walls including making good the same with common burnt clay F.P.S (non modular) bricks | Each | 339.15 | 339.15 | 150.0 | False | None | None | False | None | False | 50872.5 | 0 | 3954724 | 153240 | None | Vol-2 Pg. No. 119 It. No. 13.16 of 2023-24 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931 | Nos | 651.0 | 651.0 | 45.0 | False | None | None | False | None | False | 29295.0 | 0 | 3954725 | 153240 | None | Vol-2 Pg. No. 145 It. No. 14.95.a of 2023-24 | Providing and fixing Bidet spray made of Stainless steel with all concealed
fitting arrangements & all necessary accesories complete. Economy Class. | Each | 880.95 | 880.95 | 10.0 | False | None | None | False | None | False | 8809.5 | 0 | 3954726 | 153240 | None | Vol-2 Pg. No. 129 It. No. 13.63 of 2023-24 | Providing and fixing PVC (S.W.R) Multi Floor Trap 10.0 cm X 7.5 cm X 5.0
cm X 4.0 cm with all fitting arrangements & all necessary accessories
complete | Each | 256.2 | 256.2 | 22.0 | False | None | None | False | None | False | 5636.4 | 0 | 3954727 | 153240 | None | Vol-2 Pg. No. 120 It. No. 13.22.2 of 2023-24 | Providing and fixing PTMT grating of approved quality and colour Rectangular type with openable circular lid | No | 212.1 | 212.1 | 22.0 | False | None | None | False | None | False | 4666.2 | 0 | 3954728 | 153240 | None | Vol-5 Pg. No. 113 It. No. 10.1.5 of 2023-24 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. for PVC pipes 75mm dia., 6 kg/sqcm & class 3 | m | 231.0 | 231.0 | 80.0 | False | None | None | False | None | False | 18480.0 | 0 | 3954729 | 153240 | None | Vol-5 Pg. No. 113 It. No. 10.1.7 of 2023-24 | Supplying PVC ringtite pipes conforming to IS 4985:2000 with latest amendments and conveying to worksite, rolling and lowering into trenches, laying true to line and level and perfect linking at joints, testing and commissioning, including loading unloading at both destinations and cuts of pipes wherever necessary including jointing of PVC pipes and specials (excluding cost of specials) with jointing of approved type, with all labour with all lead & lift including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excavation etc. complete and giving necessary hydraulic test to the required pressure as per ISS (Contractor will make his own arrangements for procuring water for testing) etc. PVC pipes 110mm dia., 6 kg/sqcm & class 3 | m | 431.55 | 431.55 | 150.0 | False | None | None | False | None | False | 64732.5 | 0 | 3954730 | 153240 | None | Vol-2 Pg. No. 125 It. No. 13.48 of 2023-24 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring confirming to IS : 5383, leaving 10mm gap for termal expansion (i) single socketed pepes 100mm diameter | m | 305.55 | 305.55 | 128.8 | False | None | None | False | None | False | 39354.84 | 0 | 3954731 | 153240 | None | Vol-2 Pg. No. 123 It. No. 13.34 of 2023-24 | Providing and placing on terrace, (at all floor levels) polyethylene water storage tanks IS : 12701 marked with cover and suitable locking arrangements, and making necessary holes for inlet, outlet and over flow pipes, but without fittings and the base support for tank | Ltr | 9.45 | 9.45 | 10000.0 | False | None | None | False | None | False | 94500.0 | 0 | 3954732 | 153240 | None | Vol-5 Pg. No. 247 It. No. 21.1.2 of 2023-24 | Water purification plants: Providing, Installation and Commissioning of automatic Water purification plant (RO+UF) with all accessories piping, product water tank on single phase power supply as per the enclosed detailed Technical Specifications including cost of material, loading and unloading and as directed by the Engineer in charge. (Ref- detailed specification enclosed seperatly). Note:- 1.The above rates mentioned are only for the preparation of estimate purpose. 2. All items are to be of BSI /NFS standards,with BSI / NFS mark . 3. Tenders to be invited for procurement. 4. No direct payment should be made under any situation or condition or on any account. 5. After commissioning of plant necessary testing to be done for the satisfactory of Engineer Incharge. Note : Refer the ANNEXURE : F for Detailed Specification of Each components For 50 LPH : Cabin Type | Each | 46200.0 | 46200.0 | 1.0 | False | None | None | False | None | False | 46200.0 | 0 |
| 1726038871000 | 0 | None | None | Buildings | Sanitary works | 634571.7 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3954733 | 153241 | None | Vol-1 Pg. No. 10 It. No. 1.17.1 of 2023-24 | Earth work excavation for pipeline trenches in all kinds of soils by mechanical means above 600 mm trench width as per drawing and technical specifications, including setting out, construction of shoring, strutting, barricading, caution lights, bracing, using sight rails & boning rods at every 100 mm whevere necessary as directed, removal of stumps and other deleterious matter, dressing of sides and levelling the bottom of trench to the extent required , utilising the available excavated earth locally for the work etc., and all other appurtenances complete in the following strata All kinds of soils. Depth upto 1.50 m | Cum | 275.1 | 275.1 | 139.5 | False | None | None | False | None | False | 38376.45 | 0 | 3954734 | 153241 | None | Vol-1 Pg. No. 7 It. No. 1.10 of 2023-24 | Refilling available earth around trenches/pipelines, cables in layers not exceeding 20 cms in depth, compacting each deposited layer by ramming after watering with a lead upto 50 m , and lift upto 1.5 m. Including cost of all labour complete as per specifications | Cum | 168.0 | 168.0 | 115.2 | False | None | None | False | None | False | 19353.6 | 0 | 3954735 | 153241 | None | Vol-5 Pg. No. 96 It. No. 9.2.6 of 2023-24 | Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN8.0 : HDPE Grade PE80-PN8.0,140mm dia | m | 934.5 | 934.5 | 30.0 | False | None | None | False | None | False | 28035.0 | 0 | 3954736 | 153241 | None | Vol-5 Pg. No. 96 It. No. 9.2.9 of 2023-24 | Supplying, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing of pipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. Note: Upto 110mm dia Coil shall be used. For Grade PE80 PN8.0 : HDPE Grade PE80-PN8.0,200mm dia | m | 1803.9 | 1803.9 | 120.0 | False | None | None | False | None | False | 216468.0 | 0 | 3954737 | 153241 | None | Vol-2 Pg. No. 131 It. No. 14.3.1 of 2023-24 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid | Each | 6275.85 | 6275.85 | 9.0 | False | None | None | False | None | False | 56482.65 | 0 | 3954738 | 153241 | None | Vol-2 Pg. No. 131 It. No. 14.1.1 of 2023-24 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests | Each | 5128.2 | 5128.2 | 1.0 | False | None | None | False | None | False | 5128.2 | 0 | 3954739 | 153241 | None | Vol-2 Pg. No. 132 It. No. 14.7.1 of 2023-24 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps | Each | 3236.1 | 3236.1 | 15.0 | False | None | None | False | None | False | 48541.5 | 0 | 3954740 | 153241 | None | Vol-2 Pg. No. 137 It. No. 14.40.2 of 2023-24 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour.600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 g. | Each | 520.8 | 520.8 | 15.0 | False | None | None | False | None | False | 7812.0 | 0 | 3954741 | 153241 | None | Vol-2 Pg. No. 136 It. No. 14.32.4 of 2023-24 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 1500x450 mm | Each | 1812.3 | 1812.3 | 3.0 | False | None | None | False | None | False | 5436.9 | 0 | 3954742 | 153241 | None | Vol-2 Pg. No. 136 It. No. 14.32.2 of 2023-24 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing Rectangular shape 457x357 mm | Each | 1068.9 | 1068.9 | 8.0 | False | None | None | False | None | False | 8551.2 | 0 | 3954743 | 153241 | None | Vol-2 Pg. No. 131 It. No. 14.4.1 of 2023-24 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flushpipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required One urinal basin with 5 litre white P.V.C. automatic flushing cistern | Each | 4676.7 | 4676.7 | 1.0 | False | None | None | False | None | False | 4676.7 | 0 | 3954744 | 153241 | None | Vol-2 Pg. No. 124 It. No. 13.40 of 2023-24 | Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover 180 x 150 mm size P type & With Non Modular common burnt clay bricks of designation 3.5 & frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design | Each | 2820.3 | 2820.3 | 8.0 | False | None | None | False | None | False | 22562.4 | 0 | 3954745 | 153241 | None | Vol-2 Pg. No. 136 It. No. 14.29 of 2023-24 | Providing and fixing 100 mm sand cast Iron grating for gully trap | Each | 49.35 | 49.35 | 8.0 | False | None | None | False | None | False | 394.8 | 0 | 3954746 | 153241 | None | Vol-5 Pg. No. 191 It. No. 16.9 of 2023-24 | Constructing brick masonry chamber of internal dimension 600x600mm and depth of 600mm (inner dimensions) with modular bricks of CD 75 in cement mortar 1:6, bed concrete 150mm thick with 1:3:6, plastering 12 mm thick with cement mortar 1:4, CC 1:2:4 coping 75mm thk for fixing CI cover & frame etc. excluding the cost of CI frame and cover. | Each | 5726.7 | 5726.7 | 18.0 | False | None | None | False | None | False | 103080.6 | 0 | 3954747 | 153241 | None | Vol-5 Pg. No. 196 It. No. 16.23.1 of 2023-24 | Supplying and fixing SFRC frame and cover conforming to IS 12592 (part-I)-1988 and IS 12592 (part-II)- 1991 with latest amendment, including cutting slabs to the required size for the opening and fixing the cover in C.C. 1:2:4 and C.M. 1:3 plastering 20 mm thick to all exposed faces, curing for 10 days with all lead and lift with appurtenances. complete Medium Duty. | Each | 2009.7 | 2009.7 | 26.0 | False | None | None | False | None | False | 52252.2 | 0 | 3954748 | 153241 | None | Vol-2 Pg. No. 69 It. No. 10.4 of 2023-24 | Extra for providing opening of required size & shape for wash basin/kitchen sink in kitchen platform, vanity counter and similar location in Granite, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. | Each | 620.55 | 620.55 | 3.0 | False | None | None | False | None | False | 1861.65 | 0 | 3954749 | 153241 | None | Vol-2 Pg. No. 133 It. No. 14.10.1.3 of 2023-24 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :Kitchen sink with drain board 510x1040 mm bowl depth 200 mm. | Each | 5185.95 | 5185.95 | 3.0 | False | None | None | False | None | False | 15557.85 | 0 |
| 1726038871000 | 0 | None | None | Buildings | Bore Well (1nos) | 304439.1 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3954750 | 153242 | None | Vol-5 Pg. No. 140 It. No. 12.4 of 2023-24 | Geophysical investigation at site for sinking borewells for supplying drinking water to the habitation either through the Hand Pump MWS or P.W.S.S, by vertical electrical sounding by adopting Venner or Schlumbergers’s method, including reconnaissance survey of geological formation. Geophysical investigation of existing ground water in the vicinity, its quality, quantity and acceptability of the users, indicating the location of the site, r commended depth of casing pipe required to seal the top unconsolidated formation including an extra depth of 1.0 metre in consolidated formation for proper seating of casing pipe, depth of drilling required to cover full depth of aquifer proposed to be tapped, probable yield and other information required including transportation of instruments and accessories to work site, engaging technical personal and labour required etc. NOTE: 1) Additional rate on item 1&2 is allowed fo drilling in over burden and fixing Casing pipes beyond 20 M (for fixing Casing pipes only) a) Above 20 M and upto 30 M - 15%, b) Above 30 M - 30% (Measurement of overburden is restricted to the depth of casing pipe fixed excluding initial depth of 20M and projection above ground level). 2) A sum of Rs. 100/- is to be deducted for Dry Borewell towards yield test | Each | 5552.4 | 5552.4 | 1.0 | False | None | None | False | None | False | 5552.4 | 0 | 3954751 | 153242 | None | Vol-5 Pg. No. 139 It. No. 12.1.1 of 2023-24 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) 0-50 Mtrs. | Rmtr | 388.5 | 388.5 | 50.0 | False | None | None | False | None | False | 19425.0 | 0 | 3954752 | 153242 | None | Vol-5 Pg. No. 139 It. No. 12.1.2 of 2023-24 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) 50-100Mtrs | Rmtr | 487.2 | 487.2 | 50.0 | False | None | None | False | None | False | 24360.0 | 0 | 3954753 | 153242 | None | Vol-5 Pg. No. 139 It. No. 12.1.3 of 2023-24 | Sinking of Borewell of 165mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m. Fixing of casing pipes, collars and cap with necessary cutting, threading and welding including transportation of rig and supporting vehicle, crew charges and cost of consumables etc., complete including yield testing at the final depth with a minimum working of compressor for one hour (Excluding cost of casing pipes, collars, cap etc., complete ) 100-150 Mtrs. | Rmtr | 517.65 | 517.65 | 10.0 | False | None | None | False | None | False | 5176.5 | 0 | 3954754 | 153242 | None | Vol-5 Pg. No. 143 It. No. 12.32 of 2023-24 | Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, material and conforming to IS 1387-1993 and manufactured by basic open hearth electric or basic oxygen process in random length of 5-7m both ends.threaded conforming to IS 554-1985 one end fixed with socket conforming to IS 4270-2001 and the other end with screwed pipes all shall be responsibaly free from defects. The tubes shall be responsible straight end should be with ISI marking weighing 25.10kg/m.prices include Collar-Medium duty. | Rmtr | 2029.65 | 2029.65 | 50.0 | False | None | None | False | None | False | 101482.5 | 0 | 3954755 | 153242 | None | Vol-5 Pg. No. 155 It. No. 13.28 of 2023-24 | Supply and delivery at site 50mm(2”) dia heavy duty unplasticized PVC Column pipes with heavy duty collars,rubber profile ring,vibration control profile ring,freezing and turbulence free leak proof EPDM ring with ISI mark with its latest amendments | m | 577.5 | 577.5 | 90.0 | False | None | None | False | None | False | 51975.0 | 0 | 3954756 | 153242 | None | Vol-5 Pg. No. 152 It. No. 13.15.7 of 2023-24 | Providing,supplying to work site, Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications,as per necessary ammendments and instructions of engineer incharge of work. For 7.50 HP - 90 LPM @ 165 m = 15 STG Outlet Dia - 2.00” | Each | 42850.5 | 42850.5 | 1.0 | False | None | None | False | None | False | 42850.5 | 0 | 3954757 | 153242 | None | Vol-5 Pg. No. 156 It. No. 13.32 of 2023-24 | Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well caps, cable clips and water tight gland cable protectors, bolts, nuts, valve and gauges,tools and equipments etc., involved in the job as per specifications, with necessary tests as per specifications, with testing of as per instructions of engineer
incharge of work. | Job | 6825.0 | 6825.0 | 1.0 | False | None | None | False | None | False | 6825.0 | 0 | 3954758 | 153242 | None | Vol-5 Pg. No. 143 It. No. 12.33 of 2023-24 | Providing and fixing MS casing collars as per IS 1239 (part-II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments | Each | 157.5 | 157.5 | 1.0 | False | None | None | False | None | False | 157.5 | 0 | 3954759 | 153242 | None | Vol-5 Pg. No. 143 It. No. 12.34 of 2023-24 | Providing and laying at site of work MS casing caps as per IS 1239 (part- II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum). The dimensions of caps and colars shall be strictly as per IS 1239 (Part-II) 1982 with all amendments including cost of material and labour charges for fixing, if any etc. complete with all lead and lifts and as directed by the Engineer in charge | Each | 172.2 | 172.2 | 1.0 | False | None | None | False | None | False | 172.2 | 0 | 3954760 | 153242 | None | Vol-5 Pg. No. 155 It. No. 13.29 of 2023-24 | Supply and delivery at site 50mm(2”) dia heavy duty CI adopter set complete suitable for uPVC Column pipes for Submersible pumpsets | Set | 1627.5 | 1627.5 | 1.0 | False | None | None | False | None | False | 1627.5 | 0 | 3954761 | 153242 | None | Vol-6 Pg. No. 7 It. No. 2.6.3 of 2023-24 | Supplying and drawing 3 core flat PVC sheathed submersible pump cable manufactured with electrolytic grade copper with flexible copper with low resistance conductor confirming to13:8130-1984 and virgin grade PVC insulation and powder coating extruded PVC sheathed suitable for working voltage upto 1100 Volts as per IS-694:1990. 3C X 6Sq.mm | m | 257.25 | 257.25 | 90.0 | False | None | None | False | None | False | 23152.5 | 0 | 3954762 | 153242 | None | Vol-5 Pg. No. 155 It. No. 13.24.3 of 2023-24 | Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog Voltmeter 1ni with Phase selector switch, Isolating switch OUTGOING for Main Electrical Pump: 1 No. MCB 1 No. DOL of S/D Starter suitable for respective HP 1 No. Electrcal Protection Like single Phase preventor, under voltage over Volage, under current over current & dry run protection suitable for the pump described above 1 no Indoor type NOTE: 1) DOL- Direct Online Starter 2) S-D- Star Delta Starter etc. complete. for outdoor 6 to 15 HP pumps | Each | 18375.0 | 18375.0 | 1.0 | False | None | None | False | None | False | 18375.0 | 0 | 3954763 | 153242 | None | Vol-5 Pg. No. 156 It. No. 13.34 of 2023-24 | Labour charges for erection of outdoor type panel board and meter board units with all necessary materials and labour, tools and equipments including providing cement concrete foundation bed etc., complete as per specification, with testing of as per instructions of engineer incharge of work | Job | 1522.5 | 1522.5 | 1.0 | False | None | None | False | None | False | 1522.5 | 0 | 3954764 | 153242 | None | Vol-5 Pg. No. 155 It. No. 13.26 of 2023-24 | Supply and delivery at site delivery of best indigenous brand new MCB (Miniature Circuit Breakers) of required capacity as per IS 88228/1978 and its latest amendments and with ISI Mark of 6/10/16/20/25/40 Amps with scalable box. | Per 3 Poles | 1207.5 | 1207.5 | 1.0 | False | None | None | False | None | False | 1207.5 | 0 | 3954765 | 153242 | None | Vol-5 Pg. No. 155 It. No. 13.25 of 2023-24 | Supply and delivery at site best indigenous brand new power capacitor as per IS 2834/1986 with latest amendments with KPTCL authorities and erection, electrification and commissioning of the same at the location of respective pump sets. | Kvar | 577.5 | 577.5 | 1.0 | False | None | None | False | None | False | 577.5 | 0 |
| 1726038871000 | 0 | None | None | Buildings | Internal Electrical works | 1943245.42 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3954766 | 153243 | None | Vol-6 Pg. No. 2 It. No. 1.2.1 of 2023-24 | Concealed conduit system :supplying……mm dia 2mm 2.5mm thick heavy guage PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive pasteetc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused wires and unused junction boxes and pipe ends should be covered using PVC end enclosers. Run with 18 SWG GI fish wire wherever necessary a) 19/20mm dia 2mm thick | Mtr | 69.3 | 69.3 | 1400.0 | False | None | None | False | None | False | 97020.0 | 0 | 3954767 | 153243 | None | Vol-6 Pg. No. 2 It. No. 1.2.2 of 2023-24 | Concealed conduit system :supplying……mm dia 2mm 2.5mm thick heavy guage PVC conduit pipe with suitable size bends, metal/PVC junction boxes adhesive pasteetc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused wires and unused junction boxes and pipe ends should be covered using PVC end enclosers. Run with 18 SWG GI fish wire wherever necessary b) 25mm dia 2mm thick | Mtr | 81.9 | 81.9 | 1000.0 | False | None | None | False | None | False | 81900.0 | 0 | 3954768 | 153243 | None | Vol-6 Pg. No. 2 It. No. 1.3.1 of 2023-24 | Groove cutting : supplying…….dia 2mm/2.5mm thick heavy guage PVC conduit pipe with bends, metal junction boxes adhesive paste etc., and bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. a) 19/20mm dia 2mm thick | Mtr | 71.4 | 71.4 | 350.0 | False | None | None | False | None | False | 24990.0 | 0 | 3954769 | 153243 | None | Vol-6 Pg. No. 2 It. No. 1.3.2 of 2023-24 | Groove cutting : supplying…….dia 2mm/2.5mm thick heavy guage PVC conduit pipe with bends, metal junction boxes adhesive paste etc., and bracing U or J hooks and cement plastering up to the surface of the brick level and run with 18 SWG GI fish wire run through out the conduit wherever necessary. b) 25mm dia 2mm thick | Mtr | 82.95 | 82.95 | 250.0 | False | None | None | False | None | False | 20737.5 | 0 | 3954770 | 153243 | None | Vol-6 Pg. No. 5 It. No. 2.2.1 of 2023-24 | Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existin PVC conduit /casing caping using copper PVC insulated multi strand 2x1.5Sqmm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete outlet. Short point upto 3Mtr from tapping point to outlet via switch box | Point | 282.45 | 282.45 | 50.0 | False | None | None | False | None | False | 14122.5 | 0 | 3954771 | 153243 | None | Vol-6 Pg. No. 5 It. No. 2.2.2 of 2023-24 | Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existin PVC conduit /casing caping using copper PVC insulated multi strand 2x1.5Sqmm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete outlet. medium point above 3Mtr upto 6Mtr from tapping point outlet via switch box | Point | 397.95 | 397.95 | 130.0 | False | None | None | False | None | False | 51733.5 | 0 | 3954772 | 153243 | None | Vol-6 Pg. No. 5 It. No. 2.2.3 of 2023-24 | Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existin PVC conduit /casing caping using copper PVC insulated multi strand 2x1.5Sqmm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete outlet. long point above 6Mtr upto 10Mtr tapping point to outlet via switch box | Point | 582.75 | 582.75 | 200.0 | False | None | None | False | None | False | 116550.0 | 0 | 3954773 | 153243 | None | Vol-6 Pg. No. 5 It. No. 2.2.4 of 2023-24 | Point wiring using copper wire without switch. Supplying and wiring adopting loop system in existin PVC conduit /casing caping using copper PVC insulated multi strand 2x1.5Sqmm copper wire without switch, the other end of the wires shall be terminated with sufficient loose length in a wood/PVC round block.complete outlet. long Two outlet in a row, above 3 Mtr upto 6Mtr from tapping point to outlet let via switches 2.3.4 | Point | 710.85 | 710.85 | 4.0 | False | None | None | False | None | False | 2843.4 | 0 | 3954774 | 153243 | None | Vol-6 Pg. No. 8 It. No. 3.4.2 of 2023-24 | Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone /c.c wall 3 way | Each | 166.95 | 166.95 | 25.0 | False | None | None | False | None | False | 4173.75 | 0 | 3954775 | 153243 | None | Vol-6 Pg. No. 8 It. No. 3.4.3 of 2023-24 | Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone /c.c wall 4-5 way | Each | 185.85 | 185.85 | 12.0 | False | None | None | False | None | False | 2230.2 | 0 | 3954776 | 153243 | None | Vol-6 Pg. No. 8 It. No. 3.4.4 of 2023-24 | Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone /c.c wall 6 way | Each | 231.0 | 231.0 | 10.0 | False | None | None | False | None | False | 2310.0 | 0 | 3954777 | 153243 | None | Vol-6 Pg. No. 8 It. No. 3.4.5 of 2023-24 | Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone /c.c wall 8 way | Each | 274.05 | 274.05 | 24.0 | False | None | None | False | None | False | 6577.2 | 0 | 3954778 | 153243 | None | Vol-6 Pg. No. 8 It. No. 3.4.6 of 2023-24 | Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone /c.c wall 10-12 way | Each | 334.95 | 334.95 | 30.0 | False | None | None | False | None | False | 10048.5 | 0 | 3954779 | 153243 | None | Vol-6 Pg. No. 8 It. No. 3.4.7 of 2023-24 | Supplying and flush mounting powder coated metal box suitable for mounting modular switch plates. The box should be firmly flush mounted after due groove cutting in brick/stone /c.c wall 16 way | Each | 381.15 | 381.15 | 28.0 | False | None | None | False | None | False | 10672.2 | 0 | 3954780 | 153243 | None | Vol-6 Pg. No. 8 It. No. 3.5.2 of 2023-24 | Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts, nuts etc., complete on the existing metal/PVC box. 3 module | Each | 169.05 | 169.05 | 25.0 | False | None | None | False | None | False | 4226.25 | 0 | 3954781 | 153243 | None | Vol-6 Pg. No. 8 It. No. 3.5.3 of 2023-24 | Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts, nuts etc., complete on the existing metal/PVC box. 4 module | Each | 183.75 | 183.75 | 12.0 | False | None | None | False | None | False | 2205.0 | 0 | 3954782 | 153243 | None | Vol-6 Pg. No. 8 It. No. 3.5.4 of 2023-24 | Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts, nuts etc., complete on the existing metal/PVC box. 6 module | Each | 245.7 | 245.7 | 10.0 | False | None | None | False | None | False | 2457.0 | 0 | 3954783 | 153243 | None | Vol-6 Pg. No. 8 It. No. 3.5.5 of 2023-24 | Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts, nuts etc., complete on the existing metal/PVC box. 8 module | Each | 298.2 | 298.2 | 24.0 | False | None | None | False | None | False | 7156.8 | 0 | 3954784 | 153243 | None | Vol-6 Pg. No. 8 It. No. 3.5.6 of 2023-24 | Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts, nuts etc., complete on the existing metal/PVC box. 10-12 module | Each | 361.2 | 361.2 | 30.0 | False | None | None | False | None | False | 10836.0 | 0 | 3954785 | 153243 | None | Vol-6 Pg. No. 9 It. No. 3.5.7 of 2023-24 | Supplying and fixing superior quality modular switch mounting poly carbonate plate with necessary supporting back plate with required nos. of machine screws, bolts, nuts etc., complete on the existing metal/PVC box. 16 Module | Each | 416.85 | 416.85 | 28.0 | False | None | None | False | None | False | 11671.8 | 0 | 3954786 | 153243 | None | Vol-6 Pg. No. 9 It. No. 3.6.1 of 2023-24 | Supplying and fixing of modular switch/socket /stepped electronic fan regulator/dimmer/telephone socket etc on excistin modular switch plate. Using group 'A' materials 6Amps one way | Each | 107.1 | 107.1 | 410.0 | False | None | None | False | None | False | 43911.0 | 0 | 3954787 | 153243 | None | Vol-6 Pg. No. 9 It. No. 3.6.2 of 2023-24 | Supplying and fixing of modular switch/socket /stepped electronic fan regulator/dimmer/telephone socket etc on excistin modular switch plate. Using group 'A' materials 6Amps 2 way | Each | 174.3 | 174.3 | 30.0 | False | None | None | False | None | False | 5229.0 | 0 | 3954788 | 153243 | None | Vol-6 Pg. No. 9 It. No. 3.6.3 of 2023-24 | Supplying and fixing of modular switch/socket /stepped electronic fan regulator/dimmer/telephone socket etc on excistin modular switch plate. Using group 'A' materials 6Amps 3 way socket | Each | 179.55 | 179.55 | 110.0 | False | None | None | False | None | False | 19750.5 | 0 | 3954789 | 153243 | None | Vol-6 Pg. No. 9 It. No. 3.6.4 of 2023-24 | Supplying and fixing of modular switch/socket /stepped electronic fan regulator/dimmer/telephone socket etc on excistin modular switch plate. Using group 'A' materials Stepped fan regulator | Each | 374.85 | 374.85 | 36.0 | False | None | None | False | None | False | 13494.6 | 0 | 3954790 | 153243 | None | Vol-6 Pg. No. 9 It. No. 3.6.7 of 2023-24 | Supplying and fixing of modular switch/socket /stepped electronic fan regulator/dimmer/telephone socket etc on excistin modular switch plate. Using group 'A' materials 16Amps 1 way switch | Each | 189.0 | 189.0 | 15.0 | False | None | None | False | None | False | 2835.0 | 0 | 3954791 | 153243 | None | Vol-6 Pg. No. 9 It. No. 3.6.10 of 2023-24 | Supplying and fixing of modular switch/socket /stepped electronic fan regulator/dimmer/telephone socket etc on excistin modular switch plate. Using group 'A' materials 32Amps DP switch | Each | 342.3 | 342.3 | 2.0 | False | None | None | False | None | False | 684.6 | 0 | 3954792 | 153243 | None | Vol-6 Pg. No. 9 It. No. 3.6.11 of 2023-24 | Supplying and fixing of modular switch/socket /stepped electronic fan regulator/dimmer/telephone socket etc on excistin modular switch plate. Using group 'A' materials 6/16Amps universal socket | Each | 247.8 | 247.8 | 15.0 | False | None | None | False | None | False | 3717.0 | 0 | 3954793 | 153243 | None | Vol-6 Pg. No. 9 It. No. 3.6.12 of 2023-24 | Supplying and fixing of modular switch/socket /stepped electronic fan regulator/dimmer/telephone socket etc on excistin modular switch plate. Using group 'A' materials TV/Telephone socket | Each | 163.8 | 163.8 | 10.0 | False | None | None | False | None | False | 1638.0 | 0 | 3954794 | 153243 | None | Vol-6 Pg. No. 9 It. No. 3.6.13 of 2023-24 | Supplying and fixing of modular switch/socket /stepped electronic fan regulator/dimmer/telephone socket etc on excistin modular switch plate. Using group 'A' materials RJ45/I.O outlet | Each | 353.85 | 353.85 | 10.0 | False | None | None | False | None | False | 3538.5 | 0 | 3954795 | 153243 | None | Vol-6 Pg. No. 5 It. No. 2.3.2 of 2023-24 | Wiring for lighting or power circuit using one of FRLS PVC insulated 1100v grade,multis and copper with low conductor resistance single core wire in open or consealed system of wiring with specified IS-694:1990 & confirming to GTP Group 'A' material 1.5 Sqmm | Mtr | 27.3 | 27.3 | 1000.0 | False | None | None | False | None | False | 27300.0 | 0 | 3954796 | 153243 | None | Vol-6 Pg. No. 5 It. No. 2.3.3 of 2023-24 | Wiring for lighting or power circuit using one of FRLS PVC insulated 1100v grade,multis and copper with low conductor resistance single core wire in open or consealed system of wiring with specified IS-694:1990 & confirming to GTP Group 'A' material 2.5 Sqmm | Mtr | 44.1 | 44.1 | 1850.0 | False | None | None | False | None | False | 81585.0 | 0 | 3954797 | 153243 | None | Vol-6 Pg. No. 5 It. No. 2.3.4 of 2023-24 | Wiring for lighting or power circuit using one of FRLS PVC insulated 1100v grade,multis and copper with low conductor resistance single core wire in open or consealed system of wiring with specified IS-694:1990 & confirming to GTP Group 'A' material 4 Sqmm | Mtr | 66.15 | 66.15 | 600.0 | False | None | None | False | None | False | 39690.0 | 0 | 3954798 | 153243 | None | Vol-6 Pg. No. 5 It. No. 2.3.5 of 2023-24 | Wiring for lighting or power circuit using one of FRLS PVC insulated 1100v grade,multis and copper with low conductor resistance single core wire in open or consealed system of wiring with specified IS-694:1990 & confirming to GTP Group 'A' material 6 Sqmm | Mtr | 96.6 | 96.6 | 400.0 | False | None | None | False | None | False | 38640.0 | 0 | 3954799 | 153243 | None | Vol-6 Pg. No. 5 It. No. 2.3.6 of 2023-24 | Wiring for lighting or power circuit using one of FRLS PVC insulated 1100v grade,multis and copper with low conductor resistance single core wire in open or consealed system of wiring with specified IS-694:1990 & confirming to GTP Group 'A' material 10 Sqmm | Mtr | 175.35 | 175.35 | 100.0 | False | None | None | False | None | False | 17535.0 | 0 | 3954800 | 153243 | None | Vol-6 Pg. No. 18 It. No. 5.19.12 of 2023-24 | Supplying and fixing regular MCB distribution boards on wall / wood board / flush mounting using required clamps, bolts, nuts etc., with provision for fixing suitable type capacity MCB's single phase / 3 phase / single door with powder coated painting. Made out of 14 SWG MS enclosure.III - Double Door 6Way TP &N | Each | 5187.0 | 5187.0 | 4.0 | False | None | None | False | None | False | 20748.0 | 0 | 3954801 | 153243 | None | Vol-6 Pg. No. 17 It. No. 5.18.1 of 2023-24 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 amps SP | Each | 435.75 | 435.75 | 30.0 | False | None | None | False | None | False | 13072.5 | 0 | 3954802 | 153243 | None | Vol-6 Pg. No. 17 It. No. 5.18.4 of 2023-24 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capacity of 10K and complete wiring as required confirming to IEC 60898. 6-32 amps DP No 6.16.3 | Each | 775.95 | 775.95 | 16.0 | False | None | None | False | None | False | 12415.2 | 0 | 3954803 | 153243 | None | Vol-6 Pg. No. 18 It. No. 5.20.10 of 2023-24 | Supplying, fixing and wiring Residual currrent circuit breaker (RCCB) 240/450V up to 300mA sensitivity on existing wood/panel board. 63 Amps 4 pole | Each | 5822.25 | 5822.25 | 4.0 | False | None | None | False | None | False | 23289.0 | 0 | 3954804 | 153243 | None | Vol-6 Pg. No. 54 It. No. 12.56 of 2023-24 | Supplying, fixing, wiring, earth electrode for grounding
conduits, I.C. cutouts and other equipment's on the meter
board using 40mm dia 2.90mm thick GI pipe 2.5 mtr
long buried in a pit … The pit should be filled with equal
proportion of salt and charcoal 150mm all-round the pipe to
complete depth. The connection from the pipe to the conduit
etc., is to be established through GI wire of size as per ISI
specification 7.3.3. of IS 732 using 12mm dia bolts, nuts,
washers and check nuts etc., the pipe shall have 16 through
holes of 12 mm dia | Nos | 3685.5 | 3685.5 | 4.0 | False | None | None | False | None | False | 14742.0 | 0 | 3954805 | 153243 | None | Vol-6 Pg. No. 54 It. No. 12.58.3 of 2023-24 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x6mm GI Strip | Mtr | 134.4 | 134.4 | 50.0 | False | None | None | False | None | False | 6720.0 | 0 | 3954806 | 153243 | None | Vol-6 Pg. No. 55 It. No. 12.58.7 of 2023-24 | Supplying and running of GI/Copper strips for grounding connections, using necessary fixing materials as required. 25x3mm Copper Strip | Mtr | 598.5 | 598.5 | 50.0 | False | None | None | False | None | False | 29925.0 | 0 | 3954807 | 153243 | None | Vol-6 Pg. No. 43 It. No. 11.3.3 of 2023-24 | Supplying of PVC Batten with integrated LED tube LED light fighting 1 x4'- 36/40 w with high quality diffuser with Life of 25000 burning hours & 70% lumen maintenance with CRI 80. Power Input: 220-240V @ 50/60Hz & Power factor 0.9 along with CE approved. 2 years Warranty against any manufacturing defect working under standard electrical condition. | Each | 1332.45 | 1332.45 | 12.0 | False | None | None | False | None | False | 15989.4 | 0 | 3954808 | 153243 | None | Vol-6 Pg. No. 47 It. No. 11.11.4 of 2023-24 | Supplying & fixing of retrofit type - LED bulb.......W with
OPAL acrylic diffuser comprising of LED source with CCT
6500 degree K, CRI 70%. efficacy 80 lumen per watt,
life 25000 burning hours and Compliance to IS 10322/IEC
60598, LM 79 & LM 80. The LED are driven by HF electronic driver integrated in the system, with PF 0.95, power loss should 5% of lamp wattage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 volts. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 9W, 6500K | Each | 161.7 | 161.7 | 30.0 | False | None | None | False | None | False | 4851.0 | 0 | 3954809 | 153243 | None | Vol-6 Pg. No. 47 It. No. 11.4.2 of 2023-24 | Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 10-12W | Each | 1332.45 | 1332.45 | 103.0 | False | None | None | False | None | False | 137242.35 | 0 | 3954810 | 153243 | None | Vol-6 Pg. No. 44 It. No. 11.4.3 of 2023-24 | Supplying of recess mounting non integrated type LED down light...... W luminaire comprising of pressure decast/ extruded aluminium housing, with spring loaded false ceiling clamps, LED of Power/COB with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level. LED's are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage, short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition. 15-18W | Each | 1754.55 | 1754.55 | 156.0 | False | None | None | False | None | False | 273709.8 | 0 | 3954811 | 153243 | None | Vol-6 Pg. No. 44 It. No. 11.6.2 of 2023-24 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition LED modular down light 1'x1' 24 W | Each | 3876.6 | 3876.6 | 12.0 | False | None | None | False | None | False | 46519.2 | 0 | 3954812 | 153243 | None | Vol-6 Pg. No. 44 It. No. 11.6.3 of 2023-24 | Supplying of recess mounting non integral type ........ LED w luminaire comprising of pressure decast/extruded aluminium housing, with spring loaded false ceiling clamps, Power LEDs with CCT 6500 degree K, CRI 70%. efficacy 100 lumen per W, 120degree beam spread, life 25000 burning hours and Compliance to IS 10322/IEC 60598, LM 79 & LM 80. The lamp compartment is enclosed with anti glare opal diffuser which enhances the lighting level LEDs are driven by HF electronic driver integrated in a separate control gear assembly., with PF 0.95, power loss should 5% of lamp Wage., short circuit & open circuit protection to be integrated in the circuit, THD less than 20%, Life as per LM 79. The operating input voltage should be between 130 to 275 V. BIS Approved and Tested by NABL/CPRI accredited laboratory with 2 years Warranty against any manufacturing defect working under standard electrical condition LED modular down light 2'x2' 36 W | Each | 4780.65 | 4780.65 | 6.0 | False | None | None | False | None | False | 28683.9 | 0 | 3954813 | 153243 | None | Vol-6 Pg. No. 47 It. No. 11.15 of 2023-24 | Supplying and fixing of LED Bulkhead of 10W with IP65 protection and IK 08 impact resistance suitable for surface and wall mounting applications. | Each | 884.1 | 884.1 | 6.0 | False | None | None | False | None | False | 5304.6 | 0 | 3954814 | 153243 | None | Vol-6 Pg. No. 9 It. No. 3.10.3 of 2023-24 | Extra for supplying 4mm thick white plastic plate and covering for junction boxes of size 110mm conduite using necessary machine screws. | No | 22.05 | 22.05 | 350.0 | False | None | None | False | None | False | 7717.5 | 0 | 3954815 | 153243 | None | Vol-6 Pg. No. 52 It. No. 12.49 of 2023-24 | Supplying & Fixing of 250-400 W lamp Holder | No | 207.9 | 207.9 | 80.0 | False | None | None | False | None | False | 16632.0 | 0 | 3954816 | 153243 | None | Vol-6 Pg. No. 4 It. No. 1.13 of 2023-24 | Supplying and fixing Metal Fan Box with Round Hook | No | 122.85 | 122.85 | 36.0 | False | None | None | False | None | False | 4422.6 | 0 | 3954817 | 153243 | None | Vol-6 Pg. No. 30 It. No. 6.1 of 2023-24 | Supplying exhaust fan of 1440 RPM of 300 mm (12") size with bracket blades complete for light duty suitable to operate on 230V 50Hz, AC Supply. | Each | 3133.2 | 3133.2 | 11.0 | False | None | None | False | None | False | 34465.2 | 0 | 3954818 | 153243 | None | Vol-6 Pg. No. 30 It. No. 6.3.1 of 2023-24 | Supplying capacitor type ceiling fan complete with down rod blades, shackle, canopies etc., for operation on 230 volts,50 cycles. Single phase AC supply conforming to ISS-374-1979 and with double ball bearing system. 48" Sweep (1200mm) Regular model (Khaitan,Crompton Greaves,Orient,Polar,Bajaj,Havells,Almonard) | Each | 3133.2 | 3133.2 | 36.0 | False | None | None | False | None | False | 112795.2 | 0 | 3954819 | 153243 | None | Vol-6 Pg. No. 56 It. No. 13.7.1 of 2023-24 | Fixing all types and all capacities fluorecent/false ceiling/spot light/CFL fittings indoor on the wall / rafter / girders using 23/0.0076" twin twisted PVC insulated wires, required nos of round blocks and clamps (if required)a)On wall/ceiling/Rafters/Girders | Each | 128.1 | 128.1 | 319.0 | False | None | None | False | None | False | 40863.9 | 0 | 3954820 | 153243 | None | Vol-6 Pg. No. 57 It. No. 13.10 of 2023-24 | Fixing a ceiling/wall mounting fan of all capacities and all types to the existing S hook together with supplying and fixing a 5 amperes ceiling rose,necessary lenth of 23/0.0076 inch PVC insluted twisted copper wire and wiring completely. | Each | 179.55 | 179.55 | 36.0 | False | None | None | False | None | False | 6463.8 | 0 | 3954821 | 153243 | None | Vol-6 Pg. No. 57 It. No. 13.14 of 2023-24 | Fixing one exhaust fan in the nitch already left in the wall with bolts and nuts and 5 A. ceiling rose with sufficient length of 23/0.0076 inch PVC insulated twin core wire. | Each | 516.6 | 516.6 | 11.0 | False | None | None | False | None | False | 5682.6 | 0 | 3954822 | 153243 | None | Vol-6 Pg. No. 34 It. No. 7.2.1 of 2023-24 | Supplying ...litres capacity vertical/horizontal type wall mounting Electrical water heater with 22 SWG copper/SS sheet metal inner Container tinned inside Fiber body outside, filled with glass wool between inner and outer container for thermal insulation complete. The inlet and outlet pipes so arranged that water flow inside results in water to flow out from the inner container without turbulence. The Inner container shall have direct immersion type copper tube nickel plate. 2kW capacity element with a neon indicator fitted with 20A capacity 25 to 85 degree Centigrade range thermostat. The water heater shall completely be wired with 40/0.0076 inch 3 core copper flexible wire of 1.5 meters length and the outer container provided with heavy gauge brackets for wall mounting. 5 Star With Fibre body 25 L | Each | 12525.45 | 12525.45 | 5.0 | False | None | None | False | None | False | 62627.25 | 0 | 3954823 | 153243 | None | Vol-6 Pg. No. 13 It. No. 32.15 of 2023-24 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part- 1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 120 Sqmm, 3.5 Core, (23 GI Strips - 4 x 0.8 mm) | Km | 479733.45 | 479733.45 | 0.05 | False | None | None | False | None | False | 23986.6725 | 0 | 3954824 | 153243 | None | Vol-1 Pg. No. 6 It. No. 1.6.1 of 2023-24 | Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and
other deleterious matter, including dressing of excavated surfaces, disposing off or leveling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m. Filling available excavated earth (excluding rock)
in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering and lift upto 1.5 m including cost of labour, tools, usage& other appurtenances required
to complete the work In all kinds of soils. Depth upto 1.50m | Mtr | 508.2 | 508.2 | 50.0 | False | None | None | False | None | False | 25410.0 | 0 | 3954825 | 153243 | None | Vol-6 Pg. No. 52 It. No. 21.07 of 2023-24 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff LT Cable 120 to 240 Sqmm | Km | 33891.9 | 33891.9 | 0.05 | False | None | None | False | None | False | 1694.595 | 0 | 3954826 | 153243 | None | Vol-6 Pg. No. 26 It. No. 59.06 of 2023-24 | Heavy Duty Copper Terminal Long Barrel 120 Sqmm Copper Terminal, Apprx Wt: 64 Gm | No | 147.0 | 147.0 | 8.0 | False | None | None | False | None | False | 1176.0 | 0 | 3954827 | 153243 | None | Vol-6 Pg. No. 52 It. No. 22.10 of 2023-24 | Making and Fixing pot head for LT UG Cable Heat shrinkable Straight Through Joint 120 to 240 Sqmm | Set | 399.0 | 399.0 | 3.0 | False | None | None | False | None | False | 1197.0 | 0 | 3954828 | 153243 | None | Vol-5 Pg. No. 95 It. No. 9.1.5 of 2023-24 | Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and rolling and lowering into trenches, laying true to line and jointing ofpipes and specials with electrofusion welding, giving hydraulic test as per relevant ISS with all lead and lifts including encasing the pipe alround to a depth of not less than 15 cms. with soft gravel or selected earth available from the excation, testing and commissioning. The
rate is exclusive of required specials and fittings wherever necessary like saddle Tee, stub ends, flanged sets, bedns, reducers etc. complete (Contractor will make his own arrangements for procuring water for testing) etc. complete. NOTE: Upto 110mm dia Coil shall be used.
For :HDPE PE 80 PN 6.0 HDPE Grade PE80-PN6.0,125mm dia | m | 638.4 | 638.4 | 50.0 | False | None | None | False | None | False | 31920.0 | 0 | 3954829 | 153243 | None | Vol-6 Pg. No. 17 It. No. 5.1.13 of 2023-24 | Supplying and fixing Moulded Case Circuit Breaker (MCCB) over the existing wood/panel board using necessary screws, bolts, nuts and wiring complete. Protection of Overload and Short circuit with thermal Magnetic/Microprocessed release and Earth Fault as per IS-13947. ( Icu = Ics)(34/9) FOUR POLE 250 A 25 kA | Each | 22460.55 | 22460.55 | 1.0 | False | None | None | False | None | False | 22460.55 | 0 | 3954830 | 153243 | None | Vol-6 Pg. No. 19 It. No. 5.33 of 2023-24 | Supplying of multi function digital meter with three line back light LCD type display for voltage,Current,frequency,Power, Powerfactor,KVA,KWH,KVARsuitable for 3 Phase,4 wire LT network with IP 54 degree of protection and completely wired as required wuth communication Port and Class 0.5s accuracy. | Each | 9780.75 | 9780.75 | 1.0 | False | None | None | False | None | False | 9780.75 | 0 | 3954831 | 153243 | None | Vol-6 Pg. No. 18 It. No. 5.21 of 2023-24 | Supplying,fixing and wiring earth leakage relay with core balanced current transformer suitable for single phase 50 Hz AC with latest microcontroller based,digital readout of percentage leakage current,programable delay/auto/manual reset facility suitable to mount on DIN rail/flush mounting on panel board. | Each | 9717.75 | 9717.75 | 1.0 | False | None | None | False | None | False | 9717.75 | 0 | 3954832 | 153243 | None | Vol-6 Pg. No. 19 It. No. 5.36 of 2023-24 | Supplying, fixing and wiring 50/5A to 400/5A 5VA Burden class 1 Current Transformer. | Each | 882.0 | 882.0 | 2.0 | False | None | None | False | None | False | 1764.0 | 0 | 3954833 | 153243 | None | Vol-6 Pg. No. 17 It. No. 5.18.9 of 2023-24 | Supplying and fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and wiring complete as required. 5.17.9)50-63Amps TPN | Each | 3242.4 | 3242.4 | 6.0 | False | None | None | False | None | False | 19454.4 | 0 | 3954834 | 153243 | None | Vol-6 Pg. No. 17 It. No. 5.16 of 2023-24 | Supplying,fixing and Fixing of Shunt trip suitable for MCCB. CBCT | Each | 1788.15 | 1788.15 | 1.0 | False | None | None | False | None | False | 1788.15 | 0 | 3954835 | 153243 | None | Vol-6 Pg. No. 20 It. No. 5.40.2 of 2023-24 | Supplying …..amps rated 3phase with netural bus bar using required capacity electrolytic alluminium strips covered with heat shrinkable coloured PVC sleeve,mounted on phenolic/ERP/DMC insulator which are mounted on powder coated 40x6 mm M.S.flat frame work in existing panel board.The bus bar shall have suitable holes for termination of incoming and outgoing cables as per IS specification with necessary bolts,nuts and washers etc.,complete. 200Amps 4x30x10mm Alluminium Strips | Rmtr | 3606.75 | 3606.75 | 4.0 | False | None | None | False | None | False | 14427.0 | 0 | 3954836 | 153243 | None | Vol-6 Pg. No. 20 It. No. 5.42.1 of 2023-24 | Fabricating supplying and mounting MS box made out 16 SWG suitable for floor/wall mounting,fully weather proof with provision for better heat dissipation, provided with hinged front cover,equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 2 coats of red oxide primer paint and finally finished with approved colour enameled metal paint etc., complete. 14SWG | Sq CM | 0.53 | 0.53 | 90000.0 | False | None | None | False | None | False | 47700.0 | 0 | 3954837 | 153243 | None | Vol-6 Pg. No. 19 It. No. 5.38 of 2023-24 | Supplying and fixing of LED type pannel board indicating lamp with reqired colour suitable for 220v A.C.50 Hz 12/24v D.C. | Each | 540.75 | 540.75 | 3.0 | False | None | None | False | None | False | 1622.25 | 0 | 3954838 | 153243 | None | Vol-6 Pg. No. 15 It. No. 5.11.5 of 2023-24 | Supplying of an load change over switches 4 poles AC-23A Duty 415V, 50Hz, AC Supply (Open Execution) 250 Amps | Each | 20254.5 | 20254.5 | 1.0 | False | None | None | False | None | False | 20254.5 | 0 |
| 1726038871000 | 0 | None | None | Buildings | External Electrification works | 767569.3 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3954839 | 153244 | None | Vol-6 Pg. No. 3 It. No. 1.01 of 2023-24 | RCC Pole - 9 Mtr Long, 145 Kg WL
(Dwg No. BESCOM/GM/QS&S/02 Dtd 24.11.2018) as
per IS-785 | Mtr | 7429.8 | 7429.8 | 4.0 | False | None | None | False | None | False | 29719.2 | 0 | 3954840 | 153244 | None | Vol-6 Pg. No. 3 It. No. 2.01 of 2023-24 | Cross Arms (MS & GI) as per IS-1977 11 kV, Horizontal Cross Arm - Mild Steel (MS)
(Dwg No. BESCOM/GM/QS&S/04 Dtd 24.11.2018) | No | 390.6 | 390.6 | 4.0 | False | None | None | False | None | False | 1562.4 | 0 | 3954841 | 153244 | None | Vol-6 Pg. No. 4 It. No. 5.01 of 2023-24 | Clamps A Type (MS & GI) as per IS-1977 RCC Pole Clamp - MS
(Dwg No. BESCOM/GM/QS&S/30 Dtd 24.11.2018) | No | 89.25 | 89.25 | 4.0 | False | None | None | False | None | False | 357.0 | 0 | 3954842 | 153244 | None | Vol-6 Pg. No. 5 It. No. 6.10 of 2023-24 | Insulator as per IS-1445 for Ceremic, IS- 7935 for GI Pin, IEC-61109 for Polymeric 11 kV, 45 kN Polymeric Insulator | No | 195.3 | 195.3 | 12.0 | False | None | None | False | None | False | 2343.6 | 0 | 3954843 | 153244 | None | Vol-6 Pg. No. 5 It. No. 7.02 of 2023-24 | ACSR Conductor as per IS-398 (Part - 2/1996) Rabbit ACSR
(6/3.35 mm Al + 1/3.35 mm St), Std Wt: 214 Kg/KM | Km | 48545.7 | 48545.7 | 0.3 | False | None | None | False | None | False | 14563.71 | 0 | 3954844 | 153244 | None | Vol-6 Pg. No. 5 It. No. 8.02 of 2023-24 | Guy Wire & GI Wire as per IS-2141 8 SWG GI Wire
(4.064 mm Dia), Std Wt: 131 Kg/KM | MT | 78792.0 | 78792.0 | 0.03 | False | None | None | False | None | False | 2363.76 | 0 | 3954845 | 153244 | None | Vol-6 Pg. No. 6 It. No. 9.02 of 2023-24 | PG Clamp Rabbit to Rabbit | No | 107.1 | 107.1 | 4.0 | False | None | None | False | None | False | 428.4 | 0 | 3954846 | 153244 | None | Vol-6 Pg. No. 7 It. No. 12.08 of 2023-24 | Distribution Transformer - 3 Phase, 11kV/433V - Stacked CRGO Core with Oil as per IS-1180 (Part-1): 2014 A. OPEN BUSHING TYPE 250 kVA, Aluminium Wdg, Star 2 (5 Star) | No | 566024.55 | 566024.55 | 1.0 | False | None | None | False | None | False | 566024.55 | 0 | 3954847 | 153244 | None | Vol-6 Pg. No. 9 It. No. 18.02 of 2023-24 | LT Distribution Box as per IS-13947 Part- 1&2 LT Distribution Box for 250 kVA DTC with MCCB's (Sheet Metal) (Dwg No. BESCOM/GM/QS&S/08 Dtd 24.11.2018) | No | 23954.7 | 23954.7 | 1.0 | False | None | None | False | None | False | 23954.7 | 0 | 3954848 | 153244 | None | Vol-6 Pg. No. 9 It. No. 19.01 of 2023-24 | Lightning Arrester as per IEC-60099-4 9 kV, 5 kA Lightning Arrester Metal Oxide Ceramic type with GROUND DISCONNECTOR
(Dwg No. BESCOM/GM/QS&S/26 Dtd 24.10.2007 | No | 966.0 | 966.0 | 1.0 | False | None | None | False | None | False | 966.0 | 0 | 3954849 | 153244 | None | Vol-6 Pg. No. 9 It. No. 20.01 of 2023-24 | HG Fuse Unit as per IS-5350 Part-2 11 kV, HG Fuse Unit with Solid Core Insulator (Dwg No. BESCOM/GM/QS&S/21 Dtd 24.11.2018) | Set | 1122.45 | 1122.45 | 2.0 | False | None | None | False | None | False | 2244.9 | 0 | 3954850 | 153244 | None | Vol-6 Pg. No. 9 It. No. 21.03 of 2023-24 | Double Pole TC Set for erection of Transformer on RCC/PSCC 9 Mtr Long Poles as per IS-1977 For 25/63/100 kVA 4/5 Star Rated Transformer on RCC Pole - 9 Mtr Long, 145 Kg WL - MS | Set | 18272.1 | 18272.1 | 1.0 | False | None | None | False | None | False | 18272.1 | 0 | 3954851 | 153244 | None | Vol-6 Pg. No. 11 It. No. 24.01 of 2023-24 | GOS as per IS-9921, IS-1977 11 kV, 200 Amps Single Break GOS (Dwg No. BESCOM/GM/QS&S/23 Dtd 24.11.2018) | Set | 9922.5 | 9922.5 | 2.0 | False | None | None | False | None | False | 19845.0 | 0 | 3954852 | 153244 | None | Vol-6 Pg. No. 12 It. No. 26.01 of 2023-24 | DP Set (2 Pole Strucrure Kit) as per IS-1977 For RCC Pole - 9 Mtr Long, 145KG WL/PSCC Pole - 9 Mtr Long, 300Kg WL - MS
(Dwg No. BESCOM/GM/QS&S/35 & 63 Dtd 24.11.2018) | Set | 6721.05 | 6721.05 | 1.0 | False | None | None | False | None | False | 6721.05 | 0 | 3954853 | 153244 | None | Vol-6 Pg. No. 16 It. No. 37.01 of 2023-24 | 11 kV, 3 Core, XPLE HTUG Cable with pressure extruded inner sheeth, ROUND WIRE ARMOURED as per IS-7098 (Part-2)
Armouring wires dia and Resistivity as per IS-3975 95 Sqmm, (54 GI Wires - 2.5 mm Dia) | Km | 934149.3 | 934149.3 | 0.03 | False | None | None | False | None | False | 28024.479 | 0 | 3954854 | 153244 | None | Vol-6 Pg. No. 20 It. No. 45.04 of 2023-24 | 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Indoor Type Cable Termination Kit for XLPE Cable 3x95 Sqmm | Set | 3931.2 | 3931.2 | 2.0 | False | None | None | False | None | False | 7862.4 | 0 | 3954855 | 153244 | None | Vol-6 Pg. No. 20 It. No. 45.10 of 2023-24 | 11 kV, Jointing & Cable Termination Kit as per IS-13573 Heat Shrinkable Outdoor Type Cable Termination Kit for XLPE Cable 3x95 Sqmm | Set | 3294.9 | 3294.9 | 2.0 | False | None | None | False | None | False | 6589.8 | 0 | 3954856 | 153244 | None | Vol-6 Pg. No. 26 It. No. 59.05 of 2023-24 | Heavy Duty Copper Terminal Long Barrel 95 Sqmm Copper Terminal, Apprx Wt: 58 Gm | No | 135.45 | 135.45 | 8.0 | False | None | None | False | None | False | 1083.6 | 0 | 3954857 | 153244 | None | Vol-6 Pg. No. 27 It. No. 60.07 of 2023-24 | Aluminium End Terminal (Lug) 95 Sqmm | No | 15.75 | 15.75 | 8.0 | False | None | None | False | None | False | 126.0 | 0 | 3954858 | 153244 | None | Vol-6 Pg. No. 54 It. No. 12.57 of 2023-24 | Supplying fixing and wiring earth electrode for grounding of lifts, transformers, DG sets etc. using 40 mm dia 2.9 mm thick 2.5m long GI pipe with GI funnel with mesh and suitable size reducer fixed on the top of the earth electrode.The funnel should be enclosed in a CC chamber of 400x400x400 mm with a cast iron cover. The earth electrode shall have staggered holes of 12 mm dia and the electrode should be covered 150 mm all-round with alternate layers of salt and charcoal from the bottom of the CC chamber. The connection from the electrode is to be established through GI strip using GI bolts and nuts | No | 4468.8 | 4468.8 | 4.0 | False | None | None | False | None | False | 17875.2 | 0 | 3954859 | 153244 | None | Vol-6 Pg. No. 43 It. No. 1.1.1 of 2023-24 | Digging of Pit 1.8 Mtr depth for errection of 9 to 10 Mtr Long Steel/RCC/PSCC supports as per approved Drawing Ordinary Soil | Per Pit | 660.45 | 660.45 | 4.0 | False | None | None | False | None | False | 2641.8 | 0 | 3954860 | 153244 | None | Vol-6 Pg. No. 44 It. No. 2.02 of 2023-24 | Erection of Poles Erection of RCC/PSCC Pole of 9 to 10 Mtr long in a pit of 1.8 Mtr depth | No | 1168.65 | 1168.65 | 4.0 | False | None | None | False | None | False | 4674.6 | 0 | 3954861 | 153244 | None | Vol-6 Pg. No. 44 It. No. 3.02 of 2023-24 | Erection of Double Pole Transformer Structure using 9 Mtr Long RCC (145 Kg WL)/PSCC (300 Kg WL) Pole including fixing of Structure Materials, Erection of Poles etc., complete for mounting of Transformer as per approved drawing For 100 to 250 kVA | Per Structure | 6261.15 | 6261.15 | 1.0 | False | None | None | False | None | False | 6261.15 | 0 | 3954862 | 153244 | None | Vol-6 Pg. No. 45 It. No. 5.01 of 2023-24 | Fixing of Cross Arm, Single Top Support, EG Stirrup, Anticlimbing Device, Guy Set, Guarding etc., Fixing of 2 Pin cross arm with Insulator and Braces fixing | No | 168.0 | 168.0 | 4.0 | False | None | None | False | None | False | 672.0 | 0 | 3954863 | 153244 | None | Vol-6 Pg. No. 46 It. No. 8.03 of 2023-24 | Erection of Transformer & Structures Erection of 200 - 250 kVA Transformer | No | 2391.9 | 2391.9 | 1.0 | False | None | None | False | None | False | 2391.9 | 0 |
|
|
---|