1725970838000 | 0 | None | None | Other Works | Construction of RCC Drain and Road in Ward No. 16 31 34 29 20 Compound wall Ward No. 03 Providing UG Cable and providing LED Street Light in Bidar City | 7293187.83 | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
---|
3952605 | 153094 | None | code01 | Plain Cement Pavement Quality M30 grade Concrete (RMC) with OPC & GGBS laid without Paver:: Construction of un-reinforced plain cement concrete pavement using RMC M-30 grade with OPC @ 270 kg/m3 and GGBS@ 90 kg/m3 (75:25 proportion) as per approved mix design procedure and thickness as per design, over a prepared sub base. The superplastisiser confirming to IS 9103-1999 Reaffirmed-2008 Coarse aggregates and Fine aggregate confirming to IS:383-2016,transported to site, laid in approved fixed side form work (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the form work). Spreading the concrete with shovels, rackers and compacted using needle, suitable plate vibrator and finished in a continuous operation including provision of separation membrane and Hessian cloth finishing to lines and grades complete including cost of all materials, labour, all lead & lift, loading charges as per specification & direction of Engineer - incharge of the work. (Groove cutting shall be paid seperately) Road Restrotion | Cum | 7112.7 | 7112.7 | 162.01 | False | None | None | False | None | False | 1152328.527 | 0 | 3952606 | 153094 | None | code02 | Earth work excavation for Foundation by mechanical means for all works & depth upto 3 m, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, including dressing of excavated surfaces, disposing off or levelling the excavated earth or sorting & stacking the selected earth for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage of machinery & other appurtenaces required to complete the work In ordinary/soft rock without blasting upto 1.5 m depth | Cum | 381.15 | 381.15 | 12.15 | False | None | None | False | None | False | 4630.9725 | 0 | 3952607 | 153094 | None | code03 | Providing and laying in position Cement Concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed, laid in layers not exceeding 150 mm thickness, well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machinery, curing, and all the other appurtenances required to complete the work as per technical specifications. Mix 1:4:8 Using 40 mm nominal size graded crushed coarse aggregates (PWD Com SR 2023-24 Vol - I Page No. 15 Item No. 2.1.2) | Cum | 5947.2 | 5947.2 | 41.24 | False | None | None | False | None | False | 245262.528 | 0 | 3952608 | 153094 | None | code04 | Supplying, fitting and placing TMT FE 550 / 550D Steel Reinforcement including cost of all materials, machinery, labour, cleaning, straightening, cutting, bending, hooking, laping/welding joints, tying with binding wire / soft annealed steel wire and other ancilary operations complete as per drawing and technical specification, All other type of structures | Tonne | 82961.55 | 82961.55 | 4.4352 | False | None | None | False | None | False | 367951.06656 | 0 | 3952609 | 153094 | None | code05 | Earth work excavation by manual means for drains, canals, waste weir, draft, approach channels, key trenches, foundation of Buildings & bridges and such simillar works in all kinds of soils, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, removal of stumps and other deleterious matter, excavated surface leveled and sides neatly dressed disposing off the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools & other appurtenaces required to complete the work. In all kinds of soils Depth upto 1.5 m | Cum | 254.1 | 254.1 | 727.2 | False | None | None | False | None | False | 184781.52 | 0 | 3952610 | 153094 | None | code06 | Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction | Cum | 110.25 | 110.25 | 180.0 | False | None | None | False | None | False | 19845.0 | 0 | 3952611 | 153094 | None | code07 | Construction of Embankment by excavating the available approved Gravel/Murrum deposited at a place or borrow pits during or prior excavation with all lifts and lead, transportation to site, spreading, grading to required slope and compacting to meet the requirement complete as per specifications, including cost of labour,rolling,water,all materials,usage& all other appurtenaces required to complete the work | Cum | 497.7 | 497.7 | 120.0 | False | None | None | False | None | False | 59724.0 | 0 | 3952612 | 153094 | None | code08 | Construction of Granular Sub-Base of required grading as per design mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401. For For Grading -II Material m3 | Cum | 2553.6 | 2553.6 | 120.0 | False | None | None | False | None | False | 306432.0 | 0 | 3952613 | 153094 | None | code09 | Cutting transverse contraction joints 3 to 4 mm wide and depth 60mm in concrete slab using concrete cutting machine with diamond studded saw within 4-8 hours of casting of bay / slab etc. complete including subsequent widening of the groove 8 to 10 mm. wide at top having depth of 15 mm. as directed by Engineer incharge | Mtr | 73.5 | 73.5 | 360.01 | False | None | None | False | None | False | 26460.735 | 0 | 3952614 | 153094 | None | code10 | Providing and laying in position Cement Concrete for all Sub structures of building, Irrigation works, Sub structure works of bridges, Drain works & other parallel works from 0.50m to 3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with super plasticisers, laid in layers, well compacted using needle vibrators, providing weep holes wherever necessary, including all lead & lifts, cost of all materials of quality, confirming to the requirements of relevant IS codes, labour, Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications. Mix 1:2:4 (M15) Using 20 mm nominal size graded crushed coarse aggregates | Cum | 9080.51 | 9080.51 | 110.88 | False | None | None | False | None | False | 1006846.9488 | 0 | 3952615 | 153094 | None | code11 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part-1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975
a) 16 sqmm 4 core (11 GI Strips 4 x 0.8 mm) | Km | 148934.1 | 148934.1 | 4.93 | False | None | None | False | None | False | 734245.113 | 0 | 3952616 | 153094 | None | code12 | Fabricating supplying and mounting MS box made out ....SWG suitable for floor /wall mounting, fully weather proof with provision for better heat dissipation, provided with hinged front cover, equipped with tamper proof locking arrangements, with suitable size clamps with necessary cable entry pipe with gland and box should be finished with 7tanks treatment with powder coated paint and finally finished with approved colour etc., complete 14 SWG | Sq CM | 0.53 | 0.53 | 7000.0 | False | None | None | False | None | False | 3710.0 | 0 | 3952617 | 153094 | None | code13 | Supply of LED Streetlight luminaire with pressure die cast aluminiumhousing bodyforoptimalthermaldissipation. Lampcompartmentcomprisingof anti glarecleardiffuser with Injection moulded polycarbonate material, delivering superiorlightoutputRatedlifeBurningHrs50000hr@Lumen Maintenance of 70%,maximum light intensityshould be between60 degreesto 70 degrees.CCT 5500K, IP66 optical and electrical compartment & impact resistance ofcompleteluminaire IK08.PowerFactor 0.9with mains, Surge Protection- Min 5KV along with Over voltage/ Overload,shortcircuit/ miss-wiringprotection.Compatible for pole mounting with outer dia of 40mmto 50mm. Universal Voltage driver to operate wide voltagerange from 100V to270V50/60Hzapplication.CompliancetoIS10322/IEC 60598, LM 79&LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location withminimized minimal tools. LED Light fixture with ........W System Power
consumption. LED Efficiency1301m/w, nominal CRI 75. Luminaire
manufacturershouldhavein-housefacilityaccreditedbyNABL/CPRI&
anyGovernmentcertifiedagency&Design&Developmentfacility certified by
ISO 9001:2008. Housing with supplier word mark/name shall be Engraved/
Embossingonthe die casthousing/Bodypart. Warrantyof 2 Years against any
manufacturingdefect working under standard electrical conditions as
mentioned above should be given by LED manufacturer & Cree/Nichia/
Lumileds/Osrammake LED Source. LEDStreetlight 90W | Each | 9303.0 | 9303.0 | 202.0 | False | None | None | False | None | False | 1879206.0 | 0 | 3952618 | 153094 | None | code14 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Sqm | 371.7 | 371.7 | 330.0 | False | None | None | False | None | False | 122661.0 | 0 | 3952619 | 153094 | None | code15 | Providing and constructing laterite size stone masonry including cost and conveyance of all materials curing etc complete as per specification I.S. 3620/1979 having compressive strength not less than 3.5 N/mm2 for saturated dry samples - For Basement in CM 1:6. | Cum | 6692.7 | 6692.7 | 12.15 | False | None | None | False | None | False | 81316.305 | 0 | 3952620 | 153094 | None | code16 | Providing 20 mm cement plaster of mix :1:4 (1 cement: 4 fine sand) to brick/stone masonry including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge | Cum | 6770.4 | 6770.4 | 26.82 | False | None | None | False | None | False | 181582.128 | 0 | 3952621 | 153094 | None | code17 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cat Eye, River Pink or equivalent. | Sqm | 2994.6 | 2994.6 | 72.46 | False | None | None | False | None | False | 216988.716 | 0 | 3952622 | 153094 | None | code18 | Providing 15 mm cement plaster on the rough side of single or half brick wall of mix 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge. | Sqm | 309.75 | 309.75 | 72.46 | False | None | None | False | None | False | 22444.485 | 0 | 3952623 | 153094 | None | code19 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. M.S. tube including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. | Kgs | 144.9 | 144.9 | 120.96 | False | None | None | False | None | False | 17527.104 | 0 | 3952624 | 153094 | None | code20 | Supplying and Fixing 40 mm dia class A GI pipe bracket upto 2.7 meters long terminated with a reducing collar of 40x25mm to which extra pipe of 175mm length is fixed for fixing MV/SV/MH/FTL street light fitting of all capacities on rail/RCC/wall/tubular pole, using suitable clA, bolts, nuts and wiring using suitable capacity wires Using 40mm dia G.I.Pipe | Each | 1551.9 | 1551.9 | 202.0 | False | None | None | False | None | False | 313483.8 | 0 | 3952625 | 153094 | None | code21 | Fabricating, supplying and erecting Swaged tubular Pole of height ...m having three sections, and providing two coats of red oxide paint and finished with two coats of enamelled paint of approved quality and colour and M.S. base plate of suitable size welded at the bottom of the Pole(as per IS) and 40 mm dia GI/flexible PVC pipe of 1m length fitted to the heavy gauge polycarbonate control box including 5 Way connector of size 167 x 125 x 82 mm for 7.5M Pole/ 200 x 160 x 98 mm for remaining length of Pole with front opening cover, with locking arrangements and suitable capacity MCB/DP switch, The Pole shall be erected in cement concrete work (1:2:4) including excavation and refilling of planting depth of the Pole to the ground level and the coping CC shall be upto 0.6m above ground level as per IS2713-7 10m (5m Hb,165.1 mm dia 4.85 mm thick x 3m Hm, 139.7 mm dia 4.50 mm thick x 2m Ht,114.3 mm dia 3.65 mm thick) as per IS 410 SP 47 | Each | 20055.0 | 20055.0 | 2.0 | False | None | None | False | None | False | 40110.0 | 0 | 3952626 | 153094 | None | code22 | Supplying and fixing telescopic M.S. bracket fabricated by using 0.5m length 4" dia telescopic M. S. pipe, with 2" dia1.5m long M.S.Bracket and are welded with suitable angle, using 6mm thick M. S. sheet, grip bolts & nuts, as required, suitable for 9 to 12 ms. M. S. tubular pole, with necessary two coats of painting, with all other accessories Single bracket 1.5 m. Length | Each | 1534.05 | 1534.05 | 12.0 | False | None | None | False | None | False | 18408.6 | 0 | 3952627 | 153094 | None | code23 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 4 mm2 | Mtr | 66.15 | 66.15 | 160.0 | False | None | None | False | None | False | 10584.0 | 0 | 3952628 | 153094 | None | code24 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1 mm2 | Mtr | 19.95 | 19.95 | 120.0 | False | None | None | False | None | False | 2394.0 | 0 | 3952629 | 153094 | None | code25 | Supplying heavy gauge PVC conduit pipe ...... mm dia..........mm thick confirming to IS 2509 with suitable size bends, metal/PVC Junction boxes, adhesive paste etc., and running before concreting the slab. The conduit should be tied to the reinforcement rods by using binding wires and unused ways of junction boxes and pipe ends should be covered using PVC end enclosures, run with 18SWG GI fish wire wherever necessary. 32 mm dia 2.5 mm thick | Mtr | 108.15 | 108.15 | 70.0 | False | None | None | False | None | False | 7570.5 | 0 | 3952630 | 153094 | None | code26 | Digging of trenche of 0.6m deep x 0.50 mtr wide refilling the trench to required ground level and consolidating etc., complete (DSR 2019-20 Page No. 41 Item no. 6.6.2) | Mtr | 142.8 | 142.8 | 70.0 | False | None | None | False | None | False | 9996.0 | 0 | 3952631 | 153094 | None | code27 | Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers. 63 A | Mtr | 421.05 | 421.05 | 12.0 | False | None | None | False | None | False | 5052.6 | 0 | 3952632 | 153094 | None | code28 | 1.1 kV, XLPE or Heat resistant PVC insulated, PVC exutruted Inner Seath Armoured LTUG Cable as per IS-1554 (Part1) or IS-7098 Part-1, Armouring strip thickness and resistivity as per IS-3975 16 Sqmm, 2 Core, (9 GI Strips - 4 x 0.8 mm) | Mtr | 92838.9 | 92838.9 | 0.07 | False | None | None | False | None | False | 6498.723 | 0 | 3952633 | 153094 | None | code29 | Laying of cable in Existing Trench/GI pipe/Stone Ware/RCC Hume pipe using Wooden/Aluminum Rollers as directed by the departmental staff 2.5 to 25 Sqmm | Mtr | 150.15 | 150.15 | 70.0 | False | None | None | False | None | False | 10510.5 | 0 | 3952634 | 153094 | None | code30 | Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polycarbonate/clear glass material, delivering superior light output Rated life Burning Hrs 50000 hr @ Lumen Maintenance of 70%, CCT 5500K, IP 66 optical and electrical compartment & impact resistance of complete luminaire IK08. Power Factor 0.9 with mains, Surge Protection- Min 5KV along with Over voltage/ Overload, short circuit/ miss-wiring protection. Compatible for pole mauling with outer dia of 40mm to 50mm. Universal Voltage driver to operate wide voltage range from 100 V to 270V 50/60Hz application. Compliance to IS 10322/ IEC 60598, LM 79 & LM 80 Adherence with RoHS. UL approved MCPCB. Top access street light with single screw to ensure ease of maintenance at the sight site location with minimized minimal tools. LED Light fixture with ....... W System
Power consumption. LED Efficiency 1301m/w, nominal CRI 75.
Luminaire manufacturer should have in- house facility accredited by
NABL / CPRI & any Government certified agency & Design &
Development facility certified by ISO 9001:2008. Housing with supplier
word mark / name shall be Engraved / Embossing on the die cast
housing / Body part Warranty of 2 Years against any
manufacturing defect working under standard electrical conditions as
mentioned above should be given by LED manufacturer & Cree/Nichia/
Lumileds/Osram make LED Source. LED Floodlight 150W | Each | 13114.5 | 13114.5 | 12.0 | False | None | None | False | None | False | 157374.0 | 0 | 3952635 | 153094 | None | code31 | Fixing halogen/metal halide /SVL/IL/LED floodlight fitting over existing pole / wall ceiling including clamps, bolts, nuts and wiring using suitable capacity wires. | Each | 170.1 | 170.1 | 12.0 | False | None | None | False | None | False | 2041.2 | 0 | 3952636 | 153094 | None | code32 | Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour 63A | Each | 4403.63 | 4403.63 | 2.0 | False | None | None | False | None | False | 8807.26 | 0 | 3952637 | 153094 | None | code33 | Supplying and fixing regular MCCB distribution Panel confirming to IS/IEC 61439 - 3 and IK09 tested as per IS/IEC 62262 with minimum IP43 protection provided with Polyurethane (PUR) gasket, with suitable earthing system, on wall/wood board/flush mounting using required cl A , bolts, nuts, etc., with provision for fixing of suitable type capacity MCCB's as an incomer for 3 phase Double door with necessary bus bar completely wired to use on 440V 3phase 4 wire powder coated painting etc., complete with a provision for fixing of single/three phase suitable capacity MCB's as outgoings confirming to IS/IEC 60898 - 2 12 Way | Each | 16305.45 | 16305.45 | 2.0 | False | None | None | False | None | False | 32610.9 | 0 | 3952638 | 153094 | None | code34 | Supply and fixing of 4pole power contactor with NO/NC contacts on existing wood/panel board using necessary bolts, nuts, washers and wiring etc., complete with AC-3 Rating and as per IS-13947. 65 A | Each | 10648.05 | 10648.05 | 2.0 | False | None | None | False | None | False | 21296.1 | 0 | 3952639 | 153094 | None | code35 | Supplying and fixing Microprocessor based Electronic timer (without contactor, Din Mounting using necessary bolts, nuts and washers etc.,.) 3-120sec setting | Each | 2430.75 | 2430.75 | 2.0 | False | None | None | False | None | False | 4861.5 | 0 | 3952640 | 153094 | None | code36 | Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS694:2010 1.5 mm2 | Mtr | 27.3 | 27.3 | 280.0 | False | None | None | False | None | False | 7644.0 | 0 |
|