| tenderSubEstimateList | | createdTs | version | createdDate | modifiedDate | workCategoryName | subEstimateName | estimateTotal | itemList |
|---|
| 1726147636000 | 0 | None | None | Other Works | PARLOUR STRUCTURE AND BRANDING WORKS | 2262784.0 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3992442 | 154520 | None | str01 | Providing and fixing of EUROBOND ACP 3 mm thick Display Name board with pressed letter having the lights within the letters As per design and specifications mentioned by the Engineer-in-Charge. (Market Rate) | Sq.Ft | 1200.0 | 1200.0 | 375.0 | False | None | None | False | None | False | 450000.0 | 0 | | 3992443 | 154520 | None | str02 | Providing andfixing of rollingshuttersofapprovedmake,madeofrequiredsizeM.S.laths, interlockedtogetherthroughtheirentirelength and jointed togetherat the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements forinside and outside locking with push and pull operation complete, including the cost of providing and fixingnecessary27.5cmlongwirespringsmanufacturedfromhightensilesteelwireof adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters. 80x1.25 mm M.S. laths with 1.25 mm thick top cover including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Vol-II, 2024 SR,P-78, Sl-11.6.1) | Sqm | 3500.0 | 3500.0 | 54.0 | False | None | None | False | None | False | 189000.0 | 0 | | 3992444 | 154520 | None | str03 | Providing and fixing of Toughened glass 10 mm thickness with hole and fixing it to the existing wallincludingcostofmaterials,labour,andcompleteasperspecifications.ASPER REQUREMENT . (Iteam NoMaterial 971) | Sqm | 2100.0 | 2100.0 | 54.0 | False | None | None | False | None | False | 113400.0 | 0 | | 3992445 | 154520 | None | str04 | Providing and fixing of Toughened glass wall 12mm thickness with hole and fixing with Door it to the wall including cost ofmaterials,labour,andcompleteasperspecifications.ASPER REQUREMENT . (Iteam NoMaterial 971) | Sqm | 4200.0 | 4200.0 | 50.0 | False | None | None | False | None | False | 210000.0 | 0 | | 3992446 | 154520 | None | str05 | Providing and fixing of 40Kg/m Density 50mm thick PU Sandwich panel with 0.4mm Galvanized MS Sheet on both sides . Cost of work includes transportation , fixing , HOM, tools & tackles, etc all complete.as per specifications and as per directions of the Engineer-in-Charge. | Sqm | 1900.0 | 1900.0 | 73.0 | False | None | None | False | None | False | 138700.0 | 0 | | 3992447 | 154520 | None | str06 | Providing and fixing precoated Sandwiched Puff Sheet of 30mm thick galvanized iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05%) total coated thickness with zinc coating 120 grams per m2 asper IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 m or as desired by Engineer-in- charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x 55 mm) with EPDM seal, complete up to any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Market Rate ) | Sqm | 1950.0 | 1950.0 | 72.0 | False | None | None | False | None | False | 140400.0 | 0 | | 3992448 | 154520 | None | str07 | Providing and fixing of EUROBOND ACP 3 mm thick with 25mm thick square Tube for Framing having the lights within the Celing As per design and specifications mentioned by the Engineer-in-Charge. | Sqm | 3500.0 | 3500.0 | 56.0 | False | None | None | False | None | False | 196000.0 | 0 | | 3992449 | 154520 | None | str08 | Providing and fixing Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes including cost of materials, labor, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge.(Vol-II, 2024 SR,P-82, Sl-11.16.1) | Kgs | 136.0 | 136.0 | 762.0 | False | None | None | False | None | False | 103632.0 | 0 | | 3992450 | 154520 | None | str09 | Providing and fixing factory made 18 mm thick single extruded WPC (Wood Polymer Composite) solid plain white color board Jali, CNC (Computer Numeric Control) routed of approved design by Engineer-in charge which are machine cut for duct/shaftcovering,partitionsandfacadescomprisingofvirginPolymerofKvalue58-60(Suspension Grade),calcium carbonate and natural fibers (wood powder/rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 g) having minimum density of 650 kg/m3 and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2 , modulus of elasticity 850 N/mm2 andresistancetospreadofflameofClassAcategorywithpropertiesofbeingtermite/borer proof,water/moistureproofandfireretardantandfixingasperrequirementatsitewith necessary stainless steel fasteners and SS screws etc., all complete as per direction of Engineer-In-Charge. (Note: M.S framework required with priming coat shall be paid separately).(Vol-II, 2024 SR,P-112, Sl-12.95) | Sqm | 4411.0 | 4411.0 | 32.0 | False | None | None | False | None | False | 141152.0 | 0 | | 3992451 | 154520 | None | str10 | Providing and fixing of Vinyl flooring (Square edge) of Size 595x595 mm and 1.5 mm thick. As per specifications and as per directions of the Engineer-in-Charge.(Market Rate) | Sq.Ft | 3000.0 | 3000.0 | 72.0 | False | None | None | False | None | False | 216000.0 | 0 | | 3992452 | 154520 | None | str11 | Providing and fixing of CLIPONS Sign Board 1.5ft X1.5ft. As per the designs, specifications mentioned by the Engineer-in-Charge. (Market Rate) | Sq.Ft | 1200.0 | 1200.0 | 70.0 | False | None | None | False | None | False | 84000.0 | 0 | | 3992453 | 154520 | None | str12 | Providing and fixing of all internal and external electrification works required for nandini kiosk which includes the following items.wire,conduit pipes,switches,sockets,ceiling fans,tube lights,ledlights,service point,cables,earthing etc which ever required shall be done at no extra cost as per the specifications,makes given by the engineer in charge.(Market rates) | LS | 130000.0 | 130000.0 | 1.0 | False | None | None | False | None | False | 130000.0 | 0 | | 3992454 | 154520 | None | str13 | Applying Primer coat and two layers of Silicon & Acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces :Two coats with paint of approved quality to give an even shade, after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labor complete as per specifications and as per directions of Engineer-in-charge. | LS | 35000.0 | 35000.0 | 1.0 | False | None | None | False | None | False | 35000.0 | 0 | | 3992455 | 154520 | None | str14 | Complete Parlour erection and installation at the site with all necessary requirements including transportation and labours charges etc.( Market rates). | LS | 45000.0 | 45000.0 | 1.0 | False | None | None | False | None | False | 45000.0 | 0 | | 3992456 | 154520 | None | str15 | Providing and Fixing 5mm sun board with eco solvent vinyl 4ft x 3ft, 8ft x 4ft. As per the designs, specifications mentioned by the Engineer-in-Charge. (Market Rate) | Sq.Ft | 195.0 | 195.0 | 200.0 | False | None | None | False | None | False | 39000.0 | 0 | | 3992457 | 154520 | None | str16 | Providing and Fixing 5mm sun board with eco solvent vinyl with Photo Frame 24'' x 24". As per the designs, specifications mentioned by the Engineer-in-Charge. (Market Rate) | Sq.Ft | 315.0 | 315.0 | 100.0 | False | None | None | False | None | False | 31500.0 | 0 |
| | 1726147636000 | 0 | None | None | Other Works | CIVIL WORKS | 336530.0 | | id | tenderSubEstimateId | categoryName | itemCode | description | uomName | baseRate | finalRate | quantity | modifyQuantityYn | minQuantity | maxQuantity | buyBackYn | buyBackValue | hideYn | netAmount | taxCount |
|---|
| 3992458 | 154521 | None | CV001C | Earth work excavation by manual means for drains,canals, waste weir draft, approach channels, key trench, foundation of Bridges and such similar works, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights, excavated surface leveled and sides neatly dressed disposing off or leveling the excavated stuff or sorting & stacking the selected stuff for reuse in a radius of 50 m and lift upto 1.5 m including cost of labour, tools, usage & other appurtenances required to complete the work.(Vol-I, Sl.No 1.5, Pn 6) | Cum | 299.0 | 299.0 | 16.0 | False | None | None | False | None | False | 4784.0 | 0 | | 3992459 | 154521 | None | CV002 | Providing and laying inposition plaincement concrete for levelling course for all works in foundation.The granite/trap/basaltcrushedgradedcoarseaggregatesandfineaggregatesasper relevantISCodesmachinemixed,laid inlayersnotexceeding 150mmthickness,well compacted using plate vibrators, including all lead & lifts, cost of all materials of quality, labour, Usage charges of machineries, curing, and all the other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement & formwork shall be paid separately)Mix1:3:6(M10)Using40mmnominalsizegradedcrushedcoarseaggregates(Vol-I, Sl.No 2.1.3, Pn 15) | Cum | 5989.0 | 5989.0 | 22.0 | False | None | None | False | None | False | 131758.0 | 0 | | 3992460 | 154521 | None | CV003 | Providing and constructing loadbearing wall with Solid Concrete blocks of size400x150x 200mm having block density morethan1800kg/m3andminimum compressive strength of 4.00N/mm2 conforming to IS2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour,scaffolding and curing,usage charges of machinery etc complete as per specifications. (Vol-2, Sl.No 6.33, Pn 17) | Sqm | 1231.0 | 1231.0 | 64.0 | False | None | None | False | None | False | 78784.0 | 0 | | 3992461 | 154521 | None | CV004 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations and other similar worksetc.inlayersnotexceeding20cmindepth,consolidatingeachdepositedlayer by ramming and watering, lead up to 50 m and lift up to 1.5 m.(Vol-I, Sl.No 1.9, Pn 7) | Cum | 266.0 | 266.0 | 70.0 | False | None | None | False | None | False | 18620.0 | 0 | | 3992462 | 154521 | None | CV005 | Providing and laying in position Reinforced cement concrete for all Super structures of building, Road works,Waterworks,Irrigationworks&superstructureworksofbridgesupto3.50 m height. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as perrelevantISCodesmachinemixedwithsuperplasticiserslaidinlayers,wellcompactedusing needlevibrators.Thecostincludesall5lead & lifts, cost of all materials, quality confirming to the requirements of relevant IS codes , labour,Usage charges of machinery, curing and all other appurtenances required to complete the work as per technical specifications.(The cost of steel reinforcement, dowel bars& formwork to be paid separately) M20Design Mix Using 20 mm nominal size graded crushed coarse aggregates(Vol-I, Sl.No 2.5.1, Pn 16) | Cum | 6630.0 | 6630.0 | 2.0 | False | None | None | False | None | False | 13260.0 | 0 | | 3992463 | 154521 | None | CV006 | Providing T.M.T steel reinforcement for R.C.C work including straightening, cutting, bending, hooking, placing in position, lapping and /or welding where ever required ,tying with binding wire and anchoringtotheadjoiningmemberswherevernecessarycompleteasperdesign(laps, hooks and wastage shall not be measured and paid) cost of materials, labour, HOM of machinery complete as per specifications. Specification No. KBS 4.6.3 - TMT bars Fe 550 (Vol-I, Sl.No 2.11.a, Pn 18) | Kgs | 89.0 | 89.0 | 206.0 | False | None | None | False | None | False | 18334.0 | 0 | | 3992464 | 154521 | None | CV007 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer)withwaterabsorptionlessthan0.08%andconformingtoIS:15622,ofapproved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ m2 including grouting the joints with white cement and matching pigments etc., complete.(Vol-2, Sl.No 9.12.2, Pn 60) | Sqm | 1145.0 | 1145.0 | 62.0 | False | None | None | False | None | False | 70990.0 | 0 |
|
|
|---|